Union nut
2
Union1
3
Union O-ring
4
Spring
5
Body
6
Cartridge OR
7 Shaped opening
8 Cartridge body
9 Cartridge spring
10 Test point / plug
Material
Norm
Brass
DZR Brass
EPDM Perox
Stainless steel
DZR Brass
EPDM Perox
Stainless steel
DZR Brass
Stainless steel
DZR Brass2
EN12165 CW617N
EN12165 CW602N
EN10270-3 1.4310HS
EN12165 CW602N
EN12164 CW602N
EN10270-3 1.4310HS
EN12164 CW602N
10
3
2
Plug with copper gaskets, test points with EPDM Perox gaskets and polypropylene ties
160510
Drawings, photos and data contained in this card are provided for information only. VIR reserves the right to change them without notice.
DN
015
H 015
L 020
020
025
032
040
050
H 050
065
"
"
"
"
1"
1"
1"
2"
2"
2"
Kv1
A
HT
HP
Valve wgt2
3
[g]
[mm] [mm] [mm] [m /h]
96
110
116
116
120
163
163
208
233
241
28
35
28
35
35
41
41
41
60
60
60
67
60
67
67
73
73
73
92
92
12
18
12
18
24
84
84
82
163
197
311 / 375
459 / 523
396 / 460
473 / 537
595 / 659
1270 / 1334
1486 / 1550
2020 / 2084
3706 / 3770
3686 / 3750
Cart. wgt
[g]
45
95
45
95
95
253
253
253
1334
1334
HP
HT
G
A
Flow regulation
accuracy +/-5% of
nominal flow
If installed, the test points allow to verify if the valve is actually working within the
range suitable for the selected cartridge.
0,02
0,03
0,04
0,05
0,06
0,07
0,08
0,09
0,10
0,11
0,12
0,13
0,14
0,15
0,16
0,18
0,20
72
108
144
180
216
252
288
324
360
396
432
468
504
540
576
648
720
Range P
[kPa]
15-170
16-220
16-220
16-220
16-220
16-220
16-220
16-220
16-220
17-220
17-220
17-220
17-220
17-220
17-220
18-220
19-220
Via Circonvallazione, 10
13018 Valduggia (VC), Italy
Tel: +39 0163 47891
Fax: +39 0163 47895
www.vironline.com
Drawings, photos and data contained in this card are provided for information only. VIR reserves the right to change them without notice.
Standard range
VIR Code
Flow
[l/s]
KRR992213.1880
KRR992215.1880
KRR992217.1880
KRR992219.1880
KRR992221.1880
KRR992224.1880
KRR992227.1880
KRR992230.1880
KRR992233.1880
KRR992236.1880
KRR992240.1880
KRR992245.1880
KRR992250.1880
KRR992255.1880
KRR992260.1880
KRR992266.1880
KRR992272.1880
0,13
0,15
0,17
0,19
0,21
0,24
0,27
0,30
0,33
0,36
0,40
0,45
0,50
0,55
0,60
0,66
0,72
Standard range
VIR Code
Flow
[l/s]
KRR994231.1880
KRR994234.1880
KRR994237.1880
KRR994240.1880
KRR994246.1880
KRR994250.1880
KRR994255.1880
KRR994258.1880
KRR994262.1880
KRR994267.1880
KRR994274.1880
KRR994283.1880
KRR994290.1880
KRR994297.1880
KRR994210.1880
KRR994212.1880
KRR994213.1880
KRR994214.1880
KRR994216.1880
KRR994217.1880
KRR994218.1880
KRR994220.1880
0,31
0,34
0,37
0,40
0,46
0,50
0,55
0,58
0,62
0,67
0,74
0,83
0,90
0,97
1,05
1,20
1,30
1,44
1,56
1,68
1,80
1,96
Flow
[l/h]
Range P
[kPa]
0,18
0,20
0,23
0,25
0,29
0,32
0,36
0,40
0,45
0,50
0,55
0,61
0,68
0,75
0,80
0,86
0,95
648
720
828
900
1044
1152
1296
1440
1620
1800
1980
2196
2448
2700
2880
3096
3420
29-440
32-440
33-440
33-440
33-440
33-440
33-440
33-440
33-440
33-440
34-440
36-440
36-440
36-440
36-440
40-440
40-440
Flow
[l/h]
Range P
[kPa]
1476
1656
1836
1980
2232
2448
2664
2844
2988
3276
3600
3996
4320
4680
5004
5904
6300
6840
7416
8028
8640
9360
26-420
26-420
26-420
27-420
27-420
27-420
27-420
27-420
27-420
28-420
28-420
28-420
29-420
29-420
29-420
30-420
31-420
31-420
32-420
34-420
35-420
38-420
468
540
612
684
756
864
972
1080
1188
1296
1440
1620
1800
1980
2160
2376
2592
1116
1224
1332
1440
1656
1800
1980
2088
2232
2412
2664
2988
3240
3492
3780
4320
4680
5184
5616
6048
6480
7056
17-240
17-240
17-240
17-240
18-240
18-240
18-240
18-240
18-240
18-240
18-240
19-240
19-240
21-240
22-240
24-240
24-240
13-230
13-230
13-230
14-230
14-230
14-230
14-230
14-230
14-230
15-230
15-230
15-230
15-230
15-230
15-230
15-230
16-230
17-230
17-230
18-230
19-230
19-230
KRR992318.1880
KRR992320.1880
KRR992323.1880
KRR992327.1880
KRR992329.1880
KRR992332.1880
KRR992336.1880
KRR992340.1880
KRR992345.1880
KRR992350.1880
KRR992355.1880
KRR992361.1880
KRR992368.1880
KRR992375.1880
KRR992380.1880
KRR992386.1880
KRR992395.1880
KRR994341.1880
KRR994346.1880
KRR994351.1880
KRR994355.1880
KRR994362.1880
KRR994368.1880
KRR994374.1880
KRR994379.1880
KRR994383.1880
KRR994391.1880
KRR994310.1880
KRR994311.1880
KRR994312.1880
KRR994313.1880
KRR994314.1880
KRR994316.1880
KRR994318.1880
KRR994319.1880
KRR994321.1880
KRR994322.1880
KRR994324.1880
KRR994326.1880
0,41
0,46
0,51
0,55
0,62
0,68
0,74
0,79
0,83
0,91
1,00
1,11
1,20
1,30
1,39
1,64
1,75
1,90
2,06
2,23
2,40
2,60
Via Circonvallazione, 10
13018 Valduggia (VC), Italy
Tel: +39 0163 47891
Fax: +39 0163 47895
www.vironline.com
Drawings, photos and data contained in this card are provided for information only. VIR reserves the right to change them without notice.
1,6
1,8
2,0
2,2
2,4
2,7
3,0
3,3
3,6
4,0
4,5
5,0
5,5
6,0
6,6
5760
6480
7200
7920
8640
9720
10800
11880
12960
14400
16200
18000
19800
21600
23760
14-230
14-230
14-230
15-230
15-230
15-230
16-230
16-230
16-230
17-230
17-230
19-230
19-230
21-230
21-230
Install the valve so that the flow direction matches the direction of the arrow indicated
on the body of the valve. Perform correct flushing of the plant before installing the
cartridge.
In order to obtain the best correct flowrate regulation the valves should be installed
using pipes of its same nominal size. Water quality should be according VDI 2035.
Use at least one strainer for each installation.
Via Circonvallazione, 10
13018 Valduggia (VC), Italy
Tel: +39 0163 47891
Fax: +39 0163 47895
www.vironline.com