Professional Documents
Culture Documents
Characteristics
ATV212H075N4
variable speed drive ATV212 - 0.75kW - 1hp 480V - 3ph - EMC - IP21
Range of product
Altivar 212
Product or component
type
ATV212
Product destination
Asynchronous motors
Assembly style
Network number of
phases
3 phases
Motor power kW
0.75 kW
Motor power hp
1 hp
380...480 V (- 15...10 %)
323...528 V
Supply frequency
50...60 Hz (- 5...5 %)
Network frequency
47.5...63 Hz
EMC filter
Line current
Complementary
Apparent power
5 kA
2.2 A at 380/460 V
2.4 A for 60 s
0.5...200 Hz
12 kHz
Switching frequency
Speed range
1...10
Speed accuracy
Torque accuracy
+/- 15 %
Transient overtorque
Regulation loop
Adjustable PI regulator
Adjustable
Automatic whatever the load
Not available in voltage/frequency ratio motor control
Local signalling
Output voltage
Isolation
Electrical connection
Terminal 2.5 mm / AWG 14 (VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES)
Terminal 6 mm / AWG 10 (L1/R, L2/S, L3/T)
The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein.
This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications.
It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof.
Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.
Main
Tightening torque
0.6 N.m (VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES)
1.3 N.m - 11.5 lb.in (L1/R, L2/S, L3/T)
Supply
Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC, +/- 5 % <= 10 A with overload and short-circuit protection
Internal supply: 24 V (21...27 V) DC - <= 200 A with overload and short-circuit
protection
Sampling duration
Response time
Accuracy
Linearity error
Positive logic (source) (F, R, RES), <= 5 V (state 0), >= 11 V (state 1)
Negative logic (sink) (F, R, RES), >= 16 V (state 0), <= 10 V (state 1)
Braking to standstill
By DC injection
Protection type
Dielectric strength
Insulation resistance
Frequency resolution
APOGEE FLN
BACnet
LonWorks
METASYS N2
Modbus
Connector type
1 RJ45
1 open style
Physical interface
2-wire RS 485
Transmission frame
RTU
Transmission rate
Data format
Type of polarization
No impedance
Number of addresses
1...247
Communication service
Monitoring inhibitable
Read device identification (43)
Read holding registers (03) 2 words maximum
Time out setting from 0.1 to 100 s
Write multiple registers (16) 2 words maximum
Write single register (06)
Option card
Operating position
Width
107 mm
Height
143 mm
Depth
150 mm
Product weight
2 kg
Power dissipation in W
55 W
19 m3/h
Environment
Electromagnetic compatibility
Pollution degree
2 IEC 61800-5-1
IP degree of protection
Vibration resistance
Shock resistance
Environmental characteristic
Noise level
51 dB conforming to 86/188/EEC
Relative humidity
Operating altitude
-25...70 C
Standards
Product certifications
CSA
C-Tick
NOM 117
UL
Marking
CE
ATV212H075N4
Dimensions
(1)
2 x M5 screws
ATV212H075N4
Mounting Recommendations
Clearance
Depending on the conditions in which the drive is to be used, its installation will require certain precautions and the use of appropriate
accessories.
Install the unit vertically:
Do not place it close to heating elements.
Leave sufficient free space to ensure that the air required for cooling purposes can circulate from bottom to the top of the unit.
Mounting Types
Type A mounting
Type B mounting
Type C mounting
By removing the protective blanking cover from the top of the drive, the degree of protection for the drive becomes IP21. The protective
blanking cover may vary according to the drive model, see opposite.
provide a flow rate at least equal to that of the drive fans (refer to the product characteristics).
ATV212H075N4
(1)
(2)
negative logic
positive logic
Sink position
(1)
PLC
(1)
PLC
2-wire control
F:
R:
(2)
Forward
Preset speed
ATV212 control terminals
3-wire control
F:
Forward
R:
Stop
RES: Reverse
(2) ATV212 control terminals
PTC probe
(2)
(3)
Analog Inputs
(2)
(4)
(2)
(2)
(5)
(2)
(2)
10
ATV212H075N4
Derating Curves
The derating curves for the drive nominal current (In) depend on the temperature, the switching frequency and the mounting type (A, B or C).
For intermediate temperatures (45C for example), interpolate between 2 curves.
Switching frequency
11