Phases[edit]
In the very early days of commercial electric power, some installations used two-phase four-wire
systems for motors. The chief advantage of these was that the winding configuration was the same
as for a single-phase capacitor-start motor and, by using a four-wire system, conceptually the
phases were independent and easy to analyse with mathematical tools available at the time.
Two-phase systems can also be implemented using three wires (two "hot" plus a common neutral).
However this introduces asymmetry; the voltage drop in the neutral makes the phases not exactly 90
degrees apart.
Two-phase systems have been replaced with three-phase systems. A two-phase supply with 90
degrees between phases can be derived from a three-phase system using a Scott-connected
transformer.
A polyphase system must provide a defined direction of phase rotation, so mirror image voltages do
not count towards the phase order. A 3-wire system with two phase conductors 180 degrees apart is
still only single phase. Such systems are sometimes described as split-phase.
Motors[edit]
Polyphase power is particularly useful in AC motors, such as the induction motor, where it generates
a rotating magnetic field. When a three-or-more-phase supply completes one full cycle, the magnetic
field of a two-poles-per-phase motor has rotated through 360 in physical space; motors with more
than two poles per phase require more power supply cycles to complete one physical revolution of
the magnetic field and so these motors run slower. Induction motors using a rotating magnetic field
were independently invented by Galileo Ferraris and Nikola Tesla and developed in a three-phase
form by Mikhail Dolivo-Dobrovolsky in 1889.[1] Previously all commercial motors were DC, with
expensive commutators, high-maintenance brushes and characteristics unsuitable for operation on
an alternating current network. Polyphase motors are simple to construct, are self-starting and have
little vibration compared with single-phase motors.
existing extra high voltage (EHV, more than 345 kV phase-to-phase) transmission line to ultra-high
voltage (UHV, more than 800 kV) standards.
Experimental high-phase-order transmission lines have been built with up to 12 phases. [citation needed]
WAPA power distributed to some U.S. national labs is six-phase. Although for normal usage, it is
divided into two three-phase banks, for the highest demand applications that need minimal rectified
DC ripple, all six phases are used. This has also been used for timing; the six-phase 60 Hz based
WAPA waveform was divided in analog to 12, 18, and 36 synched phases per second for national
laboratory distribution.[citation needed] The BEVALAC particle accelerator used the WAPA-based six-phase
timing in generating a once-every-six-second particle pulse. It accepted the 2-ms injector pulse,
tunable to the microsecond, which proved to wanderbecause the WAPA frequency itself wandered
at the nanosecond level.[citation needed][clarification needed]