WIRED REMOTE CONTROLLER INSTALLATION & OPERATING MANUAL


The remote controller on the system
The remote controller transmits the signals to the system.

FEATURES OF THE REMOTE CONTROLLER- DOOR OPEN

HUMIDIFIER OPERATION

SET TEMP
ROOM TEMP

CHECK

HEATER

FAN SPEED
HI
MED
LO
TEST RUN

TIMER
ON
OFF

FILTER

6
5
9
4

Set

8
10

OPERATION DISPLAY

Displays the operating conditions.

Operation starts when this button is pressed,


and stops when the button is pressed again.

Used to set the temperature when the desired


temperature is obtained.

FAN OPERATION BUTTON

Used to circulate room air without cooling or


heating.

Used to turn on a humidifier when a humidifier


is installed.

10

TIMER SET BUTTON


Used to set the timer when the desired time is
obtained.

ROOM TEMPERATURE CHECKING


BUTTON
Used to check the present room temperature.

Humidifier ON/OFF Button

OPERATION MODE SELECTION


BUTTON
Used to select the operation mode.
Cooling Operation Mode.
Soft Dry Operation Mode.

ON/OFF BUTTON

SET TEMPERATURE BUTTON

hr.

HEATER BUTTON
Used to turn on an electric Heater when an
electric heater is installed.

FILTER SIGN DELETING BUTTON


Used to delete Filter cleaning sign.

When the air conditioner is turned off by a power failure, it is restarted


automatically in the previous operation mode after a power recovery.

File Tab Position: 6

Rev. No.: 1

Installation of remote controller


Install the remote control box and cord correctly.

POINT OF REMOTE CONTROLLER INSTALLATION


As the room temperature sensor is in the remote controller, the remote control box should be installed in such
places away from direct sunlight and high humidity and direct supply cold air to maintain proper space
temperature.

INSTALLATION OF THE REMOTE CONTROL


BOX

ROUTING OF THE REMOTE CONTROL CORD


Keep the remote control cord away from the
refrigerant piping and the drain piping.
To protect the remote control cord from electrical
noise, place the cord at least 5cm away from other
power cables. (Audio equipment, Television set, etc)
If the remote control cord is secured to a wall, provide
a trap at the top of the cord to prevent water droplets
from running.

Select places that is not splashed by water.


Select control position after receiving customer
approval.
The room temperature sensor of the thermostat for
temperature control is built in remote controller.
This remote controller equipped with liquid crystal
display. If this position is higher or lower, display is
difficult to see.
(The standard height is 1.2~1.5m high)

ELECTRICAL WIRING TO THE INDOOR UNIT


Remote controller

Be sure to connect
the wires to CN REMO

(Main board)
CN REMO

Make sure that wire color


and indicated color at label
are matched on unit side
and remote controller side.

Brown
Red
Yellow

Yellow, Red, Brown

The maximum length of the cord is 70m.


If the length of the cord exceeds 50m, use a wire size greater than 0.5mm2.

WHEN THE REMOTE CONTROLLER IS


INSTALLED WITH THE CORD EXPOSED.

DISASSEMBLING OF THE REMOTE CONTROLLER

el

Lever carefully
under plate and open
using a screw
driver, etc.

PROCEDURE OF INSTALLATION
1. Fix the under plate on the wall by self tapping
screws (accessory).
2. Make a slit (Part A) at the top side of the remote
control body by nipper.
3.Rout the cord as shown in the following figure. In
this case, push the cord into the grooved around
the case(Part B).
4. Hook the remote control unit on the under plate.

Front case

Th

ow

er

pa

rt
Remote
controller
body

WHEN THE REMOTE CONTROLLER IS


INSTALLED WITH THE CORD BURIED.
PROCEDURE OF INSTALLATION
1. Fix the under plate on the switch box by
screws(Local supply). In this case, fit the under
plate on the wall, and be careful of deformation.
2. Receive the remote control cord in the switch box.
3. Hook the remote control unit on the under plate.

Remote
control cord
(Part A)

Remote
control unit

Face of wall
Upper notch

Face of wall
Upper notch
Under plate
Tapping screw
(Accessory)
Upper flange
Push hand
(Part B)
Lower notch

FIXING OF REMOTE
CONTROL CORD
1. Fix the cord clamps on the
wall by 3 tapping
screws(Local supply).
2. Fix the remote control cord.

Under plate
Remote
control unit
Screw
(Local supply)
Remote
control cord
Lower notch
Switch box
(Local supply)

Cord
clamp

How to use the Operation Mode Selection button


Cooling Operation

1
HUMIDIFIER OPERATION

SET TEMP
ROOM TEMP

HI
MED
LO

DEFROST

TEST RUN

CHECK

HEATER

PREHEAT

FAN SPEED

TIMER
ON
OFF
hr.

FILTER

Press the ON/OFF button.

Open the door of the remote controller. To select Cooling operation, press the
Operation Mode Selection button.
Each time the button is pressed, the operation mode is shifted in the direction of
the arrow.
HUMIDIFIER OPERATION

SET TEMP
ROOM TEMP

Set

CHECK

HEATER

PREHEAT

DEFROST

FAN SPEED
HI
MED
LO
TEST RUN

TIMER

HUMIDIFIER OPERATION

ON
OFF
hr.

FILTER

CHECK

HEATER

Cooling

SET TEMP
ROOM TEMP

PREHEAT

DEFROST

FAN SPEED
HI
MED
LO
TEST RUN

TIMER
ON
OFF
hr.

FILTER

Soft Dry

Set the temperature lower than the room temperature. The temperature can be
set within a range of 18C~30C in 1C increment.
HUMIDIFIER OPERATION

SET TEMP

FAN SPEED

ROOM TEMP

CHECK

HEATER

PREHEAT

DEFROST

TIMER

To raise the temperature


To lower the temperature

ON
OFF

HI
MED
LO

hr.

TEST RUN

FILTER

Soft Dry Operation

1
HUMIDIFIER OPERATION

SET TEMP
ROOM TEMP

HI
MED
LO

DEFROST

TEST RUN

CHECK

HEATER

PREHEAT

FAN SPEED

Press the ON/OFF button.

TIMER
ON
OFF
hr.

FILTER

the door of the remote controller. To select Soft Dry operation, press the
Operation Mode Selection button.
2 Open
Each time the button is pressed, the operation mode is shifted in the direction of
the arrow.
HUMIDIFIER OPERATION

Set

SET TEMP
ROOM TEMP

CHECK

HEATER

PREHEAT

DEFROST

FAN SPEED
HI
MED
LO
TEST RUN

TIMER

FILTER

HUMIDIFIER OPERATION

SET TEMP
ROOM TEMP

HI
MED
LO

DEFROST

TEST RUN

CHECK

HEATER

PREHEAT

FAN SPEED

CHECK

HEATER

PREHEAT

DEFROST

FAN SPEED
HI
MED
LO
TEST RUN

TIMER
ON
OFF
hr.

FILTER

Soft Dry

In this mode, desired temprature will disappear.


It is impossible to set temperature, when you have selected Soft Dry operation.

Air Circulation Mode(Fan Operation Mode)

SET TEMP
ROOM TEMP

hr.

Cooling

HUMIDIFIER OPERATION

ON
OFF

Circulate the room air without cooling or heating.

Press the ON/OFF button.

TIMER
ON
OFF
hr.

FILTER

2 Open the door of the remote controller. Press the Fan button.
HUMIDIFIER OPERATION

SET TEMP
ROOM TEMP

Set
CHECK

HEATER

PREHEAT

DEFROST

FAN SPEED
HI
MED
LO
TEST RUN

TIMER
ON
OFF
hr.

FILTER

If you want to change this mode, press operation selection button.


Selecting this mode, it is impossible to change the desired temperature.

Electric Heater Operation Mode(Electric Heater is an option)

Open the door of


remote controller.
Press the heater
button. (Operation will
start after 10
seconds.)

HUMIDIFIER OPERATION

SET TEMP
ROOM TEMP

CHECK

HEATER

PREHEAT

DEFROST

FAN SPEED

TEST RUN

Set the temprature


upper than the room
temprature.
The temprature can
be set within a range
of 16C~30C in 1C
increment.

TIMER
ON
OFF

HI
MED
LO

hr.

FILTER

Set

HUMIDIFIER OPERATION

SET TEMP

FAN SPEED

ROOM TEMP

HI
MED
LO

DEFROST

TEST RUN

CHECK

HEATER

PREHEAT

TIMER
ON
OFF
hr.

FILTER

Set

To stop this operation, press the electric heater operation button once again or ON/OFF button, then all functions will stop.
If the MICOM takes the singnal of stopping this mode, approximately 60 seconds delay time is set to cool the electric heater.

In Cooling Mode and Fan Operation Mode, it is impossible to operate this Mode.

Humidifier Mode(Humidifier is an option)


Open the door of remote controller.
Press the humidifier ON/OFF
button.
It is possible to select humidifier
function in Cooling mode, Fan
Operation mode or Heating mode.
Humidifier will be operated with
previous operation mode.

HUMIDIFIER OPERATION

SET TEMP

FAN SPEED

ROOM TEMP

HI
MED
LO

DEFROST

TEST RUN

CHECK

HEATER

PREHEAT

Humidifier can be operated


alone. If you press humidifier
ON/OFF button in operation
OFF mode, the humidifier and
the indoor fan start operating
together and LCD displays
Humidifier but doesnt display
set temperature.

TIMER
ON
OFF
hr.

FILTER

Set

Delay ON/OFF Timer Setting


1

Press the Set buttons to turn Timer ON or OFF.

Press the Time Setting buttons until the desired time


is set. (up to 24 hours)

To cancel the set timer.


If you want to cancel the timer Set
mode, press again the Set button.

Set

NOTE: Select one of the following two types of operation.


Delay OFF Timer is selected when the unit is ON.
Delay ON Timer is selected when the unit is OFF.

ATION

SET TEMP
ROOM TEMP

HI
MED
LO

DEFROST

TEST RUN

CHECK

HEAT

FAN SPEED

TIMER
HUMIDIFIER OPERATION

hr.

HEATER
FILTER

SET TEMP
ROOM TEMP

OFF

HI
MED
LO

DEFROST

TEST RUN

CHECK

PREHEAT

FAN SPEED

Set

TIMER
ON

hr.

FILTER

Delay OFF Timer


Delay ON Timer
If the settings are cancelled by a power failure.
Press the On/Off Button, and then set the timer again as desired time according to Timer Setting Procedure.

Self-Diagnosis Function
'CHECK' will flash on the remote controller display when a problem occurs. Then please contact your dealer.

Air-filter Checking Function


- 'FILTER' will display on the remote controller display when an air filter is polluted. Then, clean air filters with reference
to Owner's Manual.
- After cleaning air-filters, press filter sign deleting button.
4

P/No.: 3828A30037C

June, 1999
Printed in Korea