SINGLE PHASE ENERGY TEST BENCH

( MAKE ADTRON / MODEL 9510)

SALIENT FEATURES :
Details (of figure) :
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
22.
23.
24.
25.
26.
27.
28.
29.
30.

Input Supply 415 / 440V 3 phase 4 Wire.


Main ON / OFF Switch.
Main Protective Fuse - Input.
Output Protective Fuse.
Phase Sequence Indicator.
Set ON / OFF Push Buttons.
P1 & P2 Output Current Terminals.
R S S / Wattmeter Current Terminals.
Output Voltage Terminals.
Current ON Indicator.
Set ON Indicator.
Voltage ON Indicator.
Current ON / OFF Switch.
Test Current / Starting Current Selector Switch.
Current Range Selector Switch.
Current Fine Control Variac.
Current Coarse Control Variac.
Voltage Current Variac.
Power Factor Fine Control Variac.
Power Factor Selector Switch.
Creep / Test Voltage Selector Switch.
Voltage ON / OFF Switch.
3 Pin Plug For Soldering Iron.
Standard Wattmeter.
Voltage Range Selector.
Burden Selector.
Ammeter.
Power Factor Meter.
Voltmeter.
Slot for Meter Suspension Rack.

NOTE :
As we are constantly trying to improve the performance of our products, their design, specification &
dimension are subject to change without further reference.

ADTRONS Model - 9510 is a Single Phase Energy Meter Test Bench with detachable meter suspension
rack having complete facility to calibrate and test single phase Energy Meters. Also Ammeters, Voltmeters,
Wattmeters and power factor meters can be tested. The bench is suitable for operation on 415 / 440 V AC 3 phase
four wire system, 50 cycles.
The VA burden of the Bench will be adequate to test upto 20 Nos. single phase energy meters at a time.
Built - in CT of accuracy class 0.2 with primary ranges 0 - 1, 5, 10 and 20 Amps and normal secondary current 5
amps is provided. The potential circuit has 0-150 volts and 0-300 volts ranges with automatic overload trip with
push button type reset facility and trip mechanism.

-1-

TECHNICAL SPECIFICATIONS
The Meter Test Bench has the following components, accessories and facilities :
a.

The test bench is of welded sheet metal constructions and painted stove gray, consisting of a left desk
base, a right desk base, a testing table with instruments panel and a built - in / detachable meter
suspension rack, a three piece table top finished with laminate, permitting quick inspection and servicing.
The test bench cabinet and the desk base together holds all the components and parts such as control
transformers, regulating devices inside and has only the insulated control knobs mounted on the outside.
The layout of the desk is such that voltage selection, regulation and indication controls are on the right side
( as the operators facing the bench ) and those of the current circuit on the left side. The height of the desk
is such that the operators standing on the floor have easy access to the readings of the meters and to all
screws and parts for adjustments ( figure of bench and rack are attached ).

b.

Independent voltage and current circuits with external control for independent operation and combined
operation of the voltage and current circuits are provided with protective fuses against short circuit.

c.

The current circuit is provided with suitable capacity transformer tapped to give 1A, 5A, 10A and 20A. Fine
control for any intermediate value is provided.

d.

There are provisions to carry out starting current test using the selector switch for different values of current
as per your requirements.

e.

Coarse and fine controls are provided to adjust current to any desired value in any of the above ranges.

f.

With the current regulator, a smooth variation of current from 0 - 120% of the set range is possible

g.

The volt - ampere capacity ( VA burden ) of the current circuit is sufficient in all ranges to supply the rated
current to meters as specified above when connected with their current coils in series and also the
instrument on the test bench.

h.

The potential circuit is provided with potential transformer of 100 VA capacity having fine control
adjustment between 0 to 300 volts to meet the full requirement of the test bench.

i.

A three phase static type phase shifting transformer with primary transformer is provided for varying the
relative phase angle between current and voltage from 90 degree LAG to 90 degree LEAD. The phase
shifting transformer is mounted inside the control desk and the rotary type selector switch is on the outside
of the desk for operation.

j.

A multi ratio precision current transformer of accuracy class 0.2 with primary ranges as above and
secondary 5 amps with switch for selective connections of a single phase R.S.S. meter / wattmeter in the
current circuit is provided.

k.

Facilities for mounting the R.S.S. meter / wattmeter etc. In the test bench is provided in the test circuit.

l.

The bench is provided with 1 No. moving iron AC Ammeter of size 144 x 144 mm square flush mounting
panel type with mirror scale, knife edge pointer, class 0.5% and 1 No. moving iron A. C. Voltmeter range 0
- 300 Volts of size 144 x 144 mm square flush mounting panel type with mirror scale, knife edge pointer,
class 0.5% and 1 No. single phase single element dynamometer type power factor meter of size 144 x 144
mm flush mounting panel type with mirror scale, knife edge pointer, class +2 degree and scale 90 degree
LAG - Unity - 90 degree Lead is provided.

m.

Necessary pilot lamps - 1 No. for the current circuit, 1 No. for the voltage circuit and 1 No. for the input
supply ON indication is provided.

n.

The bench is supplied with detachable meter suspension rack made out of sheet metal and painted gray
and fitted with voltage and current terminals and wired appropriately. The height of the rack is so designed
that the height of the meters fixed for testing will be within the reach of the person who is testing the
meters, and the testing can be done conveniently without using any ladders etc.

-2-

o.

The internal wiring is systematically done and all terminals are provided with numbered ferrules.

p.

The test bench is energised with a push button switch and the switch is installed on the desk top.

1.

INPUT :

3 x 240 / 415 Volts, A.C. 3 phase 4 wire system, 50 cycles.


2.

OUTPUT :

CURRENT CIRCUIT
Current Regulation

0 - 20 amps continuously variable with coarse and fine controls

Current Range Selection

0 - 1 - 5 - 10 and 20 Amps.

Capacity

To test upto 20 Nos. single phase energy meters at a time.

Starting Current

Separate switch for starting current test on energy meters is


Provided.

0 - 250 volts, AC continuously variable.

Range of Power

90 degree LAG to 90 degree lead.

Factor Variation

Range selection with a 5 position rotary switch marked as 90 degree lag,


60 degree lag, Unity, 60 degree lead and 90 degree lead.

VOLTAGE CIRCUIT
Voltage Output
Power Factor Regulation

3.

FOLLOWING CONTROL AND INDICATORS ARE PROVIDED :

a.
b.
c.
d.
e.
f.
g.
h.

Control Switches.
Mains ON / OFF Switch.
ON push button - Green colour.
OFF push button - Red colour.
Current range selector switch - Off, 1A, 5A, 10A and 20A.
Control switch for starting current test voltage ON / OFF switch.
Power factor selection switch 5 position - 90 degree lag, 60 degree lag, Unity, 60 degree lead and 90
degree lead.
Creep Test - 2 Position switch with normal volts / creep volts to obtain 110% of 230 volts in creep position

4.

INDICATION LAMPS :

a.
b.
c.
d.

Mains ON.
Current ON.
Voltage ON.
Phase sequence indicator - correct green colour and wrong - red colour.

5.

INDICATING INSTRUMENTS :

1 No. A. C. Ammeter of size 144 x 144 mm square flush mounted with knife edge pointer and antiparallax
mirror scale, class 0.5% of F.S.D., scale 0 - 120%, of the range selected.
1 No. Voltmeter A.C. of size 144 x 144 mm square flush mounted with knife edge pointer and antiparallax
mirror scale, class 0.5% of F.S.D. Range 0 - 300 volts.

-3-

1 No. single phase single element dynamometer type power factor meter of size 144 x 144 mm flush
mounted type with antiparallax mirror scale, knife edge pointer etc.
Scale 0.5 Lag Unity 0.5 Lead.
6.

METER SUSPENSION BACK :

Suitable detachable meter suspension rack duly wired to hold upto 20 Nos. single phase energy meters to test at a
time.
7.

FOLLOWING TERMINALS ARE PROVIDED :

P1
V1
S1
V1

P2
2
S2
V2

:
:
:
:

Test Current
Test Voltage
RSS/Wattmeter/Energy meter current terminals.
RSS/Wattmeter/Energy meter current terminals.

NOTE :
The Test Bench is supplied with a detailed instruction manual consisting of:
1.
2.
3.
4.
5.
6.

Necessary Circuit Diagram.


Drawings.
List of materials.
Operating instructions.
Works test certificates for Transformers, Meters and Meter Test Bench.
Connecting leads for meters under test.

SPECIFICATIONS ARE SUBJECT TO CHANGE DUE TO CONSTANT


DEVELOPMENTS WITHOUT ANY PRIOR NOTICE

-4-