HandyChecker(Ver.

3)Download Manual
This is the Manual to download the Mechatro-controller software with HandyChecker (ver.3).
Items Needed:
1.Excavator
2.SDT Kit or Down load Harness
3.Laptop
4.Proper Version of Machine Model Software
1.Applicable Excavators to use Checker Software on
Following excavator's software are able to be downloaded with HandyChecker(ver.3):
Acera Mark 8 Series(SK200-8SK210LC-8...)
Dynamic Acera , and all the other elder models
2.Necessary Parts
Following Parts are necessary to download with HandyChecker(ver.3):
PC(with Serial Port)
Download Cable
HandyChecker(ver.3)

3.Download Procedure
Connection of Download Cable
3-1.Place Excavator's keyswitch in the "off" position.
3-2.Locate and remove the access cover (behind operator's seat), and remove the
cover from Fuse/Relay Box.
Fuse/Relay Box Cover

Fig. Place of the Fuse & Relay Box


3-3.Locate the download Connector on the left side of Fuse & Relay Box. Remove the
white blank connector cap and connect the download cable to at this location.
Remove
Blank
Connector

Fig. 3.3 Location of the Download

Download Connector

3-4.Connect the Download Connector to PC and Key on the Excavator, Start the Laptop

Note:

3-5.When the DATA COMMUNICATION ERROR is shown on Cluster-Gauge,


proceed to 3-6.
(if Data Comm. Error is not shown, proceed to Section [4.Trouble Shooting]-[4-1.
case of communication failure])

Confirmation of proper version of HandyChecker


3-6.Start the HandyChecker. ( Launch screen is shown below. )

Fig. Starting Screen


3-7.Click the on Toolbar-[Help]-[Version(A)], and confirm the version of HandyChecker.
Version information is shown on second row.Confirm this number is three.
(if not,install the HandyChecker(ver.3) and retry from 3-1.)

Fig.HandyChecker ver.3.0.0 Version Information

Download
3-8.From the launch screen click on the "Download" button on the Starting screen.
When the pop-up message: "", it is
impossible to download software. In this case, proceed to [4. Trouble Shooting]
-[4-1. case of communication failure] to check as described, and retry from 3-1.

Fig.Error Message
(This message is Japanese)
3-9.Download Screen is displayed when the HandyChecker starts normally.

Fig.HandyChecker Download Screen

3-10.Click on the [Check] button(right side of screen). Click on [OK] button of pop-up
message window.

Fig.Message to confirm connection


It is impossible to download when the following error messages shown below are displayed.
Proceed to [4.Trouble Shooting]-[4-2.in case of communication failure] to
check as described, and retry from 3-1.

Fig.Error Message-(1)

Fig.Error Message-(2)
(This message is Japanese)

3-11.Numerical value is displayed on [Speed Change] box and [Communication


Speed] box when the HandyChecker starts normally.
(value is different according to the model of machine being downloaded.)
If working with Dynamic Acera Speed should equal 19200 - ( 9600 is N/G Value)

Fig.Download Speed Screen


(when downloading to SK200-8)

Selection of Machine Software


3-12.Click on the [Reference ] button to display the file selection window.
Select the software version to be downloaded.

Machine Software Version


File Names Vary by
machine model size. (Your
machine may have a
different name)

Fig.Download file selection window


(when downloading to SK200-8)
3-13.Reconfirm that proper version is present in File Name window. Then Click on the
[START] button when you select the software.
Download starts automatically and progress rate is displayed on the progress-bar in the center
of the screen.
3-14.Download finishes when the "Finished Screen - " is displayed.
(note: it is not abnormal though the "" is displayed in less than
100% at the progress rate once)
When [] or [] is displayed, proceed to
[4.Trouble Shooting]-[4-2.Case of writing failure] to check as described
and retry from 3-1.
Reconfirm
Version

Fig. Download Finish Screen


(when downloading to SK200-8)

Fig. Writing Failure Screen-(1)


(when downloading to SK200-8,
This message is Japanese version)

Fig. Download Failure Screen-(2)


(when downloading to SK200-8,
This message is Japanese version)

Confirmation of Proper Download


3-15.Place Keyswitch in the "OFF" position and remove the download cable from
Fuse/Relay Box download connector. Close the Handy Checker program and shut
3-16.Enter into the Service Diagnosis Mode by truning Keyswitch to "ON" while with
holding Buzzer-Stop switch on cluster gauge and confirm the parts number and
software version. When the wrong software is downloaded, reinstall from item # 3-1.

Software Part Number


Software Version

Fig. Service Diagnosis Mode


(when downloading to SK200-8,
This screen shot is Japanese version)
3-17.Place Blank connector back in connector in Fuse/Relay box and Put back
the covers taken off in item # 3-2.). Download is now complete.
4.Trouble Shooting
4-1.Case of communication failure
This failure is maybe caused by:
Download Cable disconnection
Broken Download Cable
Mechatro-Controller disconnected

Connect the Cable.


Inspect / Replace the Cable.
Connect the fuses.

confirm above, and retry downloading.


4-2.Case of writing failure
Check the items described in 4-1.
When the failure occurs after the check, there is possibility that the MechatroController is broken. Replace the Mechatro-Controller and retry.