Professional Documents
Culture Documents
OMU
Repeaters
Directional
Couplers
OMU
Base station
Optical
Fiber
In the downlink direction, the OMU picks up the signal from the base station, converts it into an optical signal and
transfers it over a fiber optical cable to the repeater. In the uplink direction the OMU receives the signal from the
repeater via the fiber optical cable, converts it to a RF signal and sends it back to the base station.
Expandable solution: Each OMU can be equipped with up to six optical modules and therefore
support up to six remote units (BSF424). If additional repeaters are to be fed from the same base
station, it is simple to expand the system with additional slave OMU units that in total will support up
to 24 remote units. If there is a shortage of fiber, it is furthermore possible to use just one fiber that
is shared between 2-4 remote sites. However, the maximum optical loss allowed for is 10 dB which
corresponds to 20 km of fiber between the OMU and the last remote unit that the OMU supports.
Remote Supervision: Only one modem is need to communicate with an OMU and its fiber fed repeaters. The modem types available are: GSM, PSTN, TCP/IP and even GSM-R. It is found inside the
OMU and communication with the fiber fed remote units is transparently handled via the fiber that
connects them. The system can be managed via the Avitec Repeater supervision and remote control
software tool, AEM (Avitec Element Manger). All communication between the OMU and the repeaters
both data communication and the transferred RF signal is managed over the same fiber link. This
gives a very reliable supervision of the radio link.
The OMU supports TETRA, TETRAPOL, GSM-R, UMTS and GSM 900, 1800 and 1900 MHz frequency
bands and is always used in combination with one or several fiber fed repeater(s):
TETRA/TETRAPOL: BSF424
GSM900:
CSF922, CSF1824
GSM1800:
CSF1822, CSF1824
GSM1900:
CSF1922, CSF1924
UMTS:
CSF2222, CSF2224
GSM-R:
CSF922-R, CSF924-R
Electrical Specifications
RF Parameters
Frequency bands
Nominal RF input power
Number of optical modules
Optical output power
Output Power (Tx) max
Operating Temperature
Automatic fiber optic loss
compensation
380-960/1710-2170 MHz
+10 dBm composite power
1-6
+5 dBm
+5 ~ +45C
Yes
Power Requirements
Power Requirements
Power Consumption
RS232
N-type Connector Female
SC/APC
Mechanical Specifications
Dimensions (w x h x d)
Weight
IP rating
Reliability Specification
Lifetime (MTBF)
84 TE x 3 HE x 290 mm
18 kg (fully equipped)
IP20
>70 000 hrs
AVITEC AB,
Mail Address: Box 7139, SE-174 07 Sundbyberg, SWEDEN
Office Address: Alln 5, 172 66 Sundbyberg
Phone:+46-8-475 47 00, Fax:+46-8-475 47 99, E-mail: info@avitec.se, www.avitec.se