You are on page 1of 54

STAAD(X) Tower

Tutorials
Last Updated: July 25, 2012

Table of Contents
MONOPOLE TOWER EIA/TIA-222-F
Creating A New Monopole Tower
............................................................................................................ 5
Adding Components
.................................................................................................................................. 6
Adding Loads
............................................................................................................................................ 8
Primary Load Cases And Analysis
............................................................................................................ 8
Reviewing Results And Creating Reports
................................................................................................. 9

MONOPOLE TOWER TIA-222-G


Creating A New Monopole Tower
.......................................................................................................... 11
Adding Components
................................................................................................................................ 13
Adding Loads
.......................................................................................................................................... 14
Primary Load Cases And Analysis
.......................................................................................................... 14
Reviewing Results And Creating Reports
............................................................................................... 16

MONOPOLE TOWER TIA-222-G


Creating A New Monopole Tower
.......................................................................................................... 19
Adding Components
................................................................................................................................ 21
Adding Loads
.......................................................................................................................................... 22
Primary Load Cases And Analysis
.......................................................................................................... 22
Reviewing Results And Creating Reports
............................................................................................... 23

SELF-SUPPORTING TOWER EIA/TIA-222-F


Creating A New Self-Supporting Tower
................................................................................................. 25
Editing The Properties
............................................................................................................................. 26
Adding Bracing
....................................................................................................................................... 27
Adding Components
................................................................................................................................ 30
Adding Loads And Load Groups
............................................................................................................ 31
Primary Load Cases And Analysis
.......................................................................................................... 32
Reviewing Results And Creating Reports
............................................................................................... 33

SELF-SUPPORTING TOWER TIA-222-G


Creating A New Self-Supporting Tower
................................................................................................. 35
Editing The Properties
............................................................................................................................. 36
Adding Bracing
....................................................................................................................................... 37
Adding Components
................................................................................................................................ 40
Adding Loads And Load Groups
............................................................................................................ 41
Primary Load Cases And Analysis
.......................................................................................................... 42
Reviewing Results And Creating Reports
............................................................................................... 43

SELF-SUPPORTING TOWER IS:802/806


Creating A New Self-Supporting Tower
................................................................................................. 45
Editing The Properties
............................................................................................................................. 46
Adding Bracing
....................................................................................................................................... 47
Adding Components
................................................................................................................................ 50
Adding Loads And Load Groups
............................................................................................................ 51
Primary Load Cases And Analysis
.......................................................................................................... 52
Reviewing Results And Creating Reports
............................................................................................... 53

STAAD(X) Tower

Tutorials

STAAD(X) Tower

Tutorials

Monopole Tower Per TIA-222-F

Monopole Tower EIA/TIA-222-F


Please note that the purpose of this tutorial is to demonstrate the general functions and locations of the tools
available in STAAD(X).Tower. For further explanations and details that are not included in this tutorial,
please refer to the User's Manual.

Creating a New Monopole Tower


Using the EIA/TIA-222-F code.
1. After launching STAAD(X) Tower, select New from the Start ribbon tab.
The STAAD(X) Tower dialog appears.
2. Select Monopole as the type of tower, then click Next >.
The Setup Wizard dialog appears.
3. Click Next > to proceed to the Tower Properties page.
4. Input the following into the Tower Properties page:
General Tower Properties

Input

Tower Name

Tapered Monopole Ex TIA222F

Unit Type

English

Country Code

US

Design Code

EIA/TIA-222-F

Length Unit and Force Unit

ft and kip

Monopole Tower Properties

Input

Type of Monopole

Tapered

Elevation At Base (ft)

Height of Tower (ft)

120

Number of Sections

Number of Sides

HexDecagonal (16)

Round Monopole Extension

(unchecked)

Click Next > to proceed to the Structural Properties page.


5. Input the following into the Structural Properties page:

STAAD(X) Tower

Tutorials

Monopole Tower per TIA-222-F


Adding Components
Member Properties

Input

Type of section

Tapered Tube

Depth/Dia of Tube at top (in)

24

Tube Thickness at top (in)

0.1875

Tube Thickness at base (in)

0.375

Galvanizing Thickness (in)

Tapered Factor (in/ft)

0.2

Material and Grade

Steel and A572 Gr. 65

Type of support

Fixed

Apply self-weight load

(checked)

Factor and Direction

-1 and Y

Click Next > and then click OK.


This exits you out of the Setup Wizard and brings you to the main work area. Your model appears in the
View pane.
6. In the Tower Model Explorer pane expand Physical Model > Objects , then right click the Sections folder
and select Show Tapered Pole SectionsTable from the pop-up menu.
The tapered pole sections table appears in the Output pane where edits can be made.
7. Input the following into the Output pane:
Section ID

Length (ft)

Lap Splice (ft)

Thickness

34

4.25

0.1875

34

5.5

0.25

34

6.25

0.3125

34

0.375

Tip: The length for Section ID 4 will automatically adjust according to the other lengths and lap
splice values; therefore, enter the first three lengths and the lap splices first. The fourth section
will automatically become 34 ft.
Note: The thickness column will automatically round your values to two decimal places.
Tip: You can further edit the tower by looking in the Tower Model Explorer pane and expanding
Physical Model > Objects > Sections . Clicking on each section will show its properties in the
Properties pane where edits can be made.
8. In the Model ribbon tab click the Save tool.
Your work so far has been saved. You may be prompted to save the file in a destination of your choice.

Adding Components
Using the EIA/TIA-222-F code.
STAAD(X) Tower

Tutorials

Monopole Tower per TIA-222-F


Adding Components
1. Under the Components ribbon tab, click the T-Arm tool.
A new Mount 1 appears in the Tower Model Explorer pane, a T-arm mount appears on the model in the
View pane, and its properties appear in the Properties pane.
2. Input the following into the Properties pane:.
Mount Properties

Input

Elevation

118 ft

No of T-Arms

3. Under the Components ribbon tab click the Pipe/Dish Mount tool.
A new Mount 2 appears in the Tower Model Explorer pane, a pipe mount appears on the model in the
View pane, and its properties appear in the Properties pane.
4. In the Properties pane change the Elevation to 110 ft.
5. In the Tower Model Explorer pane expand Mount 2 and click on Mount Pipe 7.
More of the pipe mount's properties appear in the Properties pane.
6. In the Properties pane, change the Orientation to Leg C.
7. In the Tower Model Explorer pane expand Mount Pipe 7 and click on Antenna 7-Panel.
The antenna's properties appear in the Properties pane.
8. Input the following into the Properties pane:
Appurtenance Properties

Input

Antenna Type

Dish

Dish Type

Parabola without Radome

Azimuth

30.00 deg

The pipe mount on the model is changed to a dish mount in the View pane, and Antenna 7-panel is
changed to Antenna 7-dish in the Tower Model Explorer pane.
9. Under the Components ribbon tab, click the Feedlines tool.
A new Feedline 1 appears in the Tower Model Explorer pane, a feedline appears on the model in the View
pane, and its properties appear in the Properties pane.
10. Input the following into the Properties pane:
Feedline Properties

Input

Coax Cable

1 5/8

Start Height

2 ft

End Height

118 ft

No. of Lines (Coaxes)

Tip: End Height must be entered before Start Height.


11. To edit or add supports, go to the Tower Model Explorer Pane and expand Physical Model and right click
on the Supports folder. You can add the type of support desired by selecting it from the pop-up menu.
The restraint options for the support selected appear in the Properties pane and can be edited.
Note: For this model, a fixed support was assigned in the Setup Wizard and can be seen if the
Supports folder is expanded.
12. Under the Model ribbon tab, click Save.
STAAD(X) Tower

Tutorials

Monopole Tower per TIA-222-F


Adding Loads
Your work so far has been saved. You may be prompted to save the file in a destination of your choice.

Adding Loads
Using the EIA/TIA-222-F code.
1. In the Tower Model Explorer pane expand Physical Model > Loads , then right click on the Load
Generation Parameters folder and select Add Wind/Ice Parameters from the pop-up menu then TIA/
EIA[222F] Definition from its pop-up menu.
A new TIA/EIA[222F] Load Def. 1 appears in the Tower Model Explorer pane and its properties appear
in the Properties pane.
2. Input the following into the Properties pane:
Zone Identification

Input

State

Alabama

County

Coffee

Note: Wind speed and ice thickness have been automatically updated to reflect the inputted
location.
Check the box next to Ice Load, then expand the Load Cases drop-down menu and check the boxes next
to all of the load cases.
The nine new load cases have been added as Load Groups 2 through 10 in the Tower Model Explorer
pane.
3. Expand each of the new load groups, then right click on each of the wind/ice loads and select Assign from
their pop-up menus, respectively.
The white boxes next to the wind/ice loads will turn green once they have been assigned and you will see
the loads applied in the View pane, respectively. The new loads have been assigned to the entire structure.
Note: Three new load groups will appear as Load Groups 11 through 13.
4. In the Model ribbon tab click the Save tool.
Your work so far has been saved. You may be prompted to save the file in a destination of your choice.

Primary Load Cases and Analysis


Using the EIA/TIA-222-F code.
1. In the Tower Model Explorer pane expand Analysis > Whole Model > Load Cases , then right click the
Primary folder and select Primary Load Case Generator from the pop-up menu.
The Primary Load Case Generator dialog appears.
2. In the Primary Load Case Generator dialog, check the following options:
Primary Load Case
1 Dead + 1 Wind 0 degree
1 Dead + 1 Wind 45 degree
1 Dead + 1 Wind 90 degree
1 Dead + 1 Wind service 0 degree
1 Dead + 1 Wind service 45 degree

STAAD(X) Tower

Tutorials

Monopole Tower per TIA-222-F


Reviewing Results and Creating Reports
Primary Load Case
1 Dead + 1 Wind service 90 degree

3.

4.
5.
6.
7.

Click OK. The six new primary load cases have been added as Primary LoadCases 1 through 6 in the
Tower Model Explorer pane.
In the Tower Model Explorer pane expand Analysis > Whole Model > Load Cases , then right click the
Primary folder and select Add Primary Load Case from the pop-up menu.
A new Primary LoadCase 7 appears in the Tower Model Explorer pane and the load case editor appears
in the Properties pane.
In the Properties pane click the drop-down menu next to Load Group Type and check Select All.
The load groups appear in the Properties pane.
Click 1:Load Group 1, input 1.2 as the Factor, then click Add.
The load group with its assigned factor appears in the Properties pane under Selected Load Groups.
Click 2:Load Group 2, input 1.6 as the Factor, then click Add.
The load group with its assigned factor appears in the Properties pane under Selected Load Groups.
Repeat steps 3 through 6 to create the following primary load cases:
Primary LoadCase Number

Load Groups and Factors

1:Load Group 1 (1.2) + 3:Load Group 3 (1.6)

1:Load Group 1 (1.2) + 4:Load Group 4 (1.6)

10

1:Load Group 1 (0.9) + 9:Load Group 9 (1.6)

The three new load cases have been added as Primary LoadCases 8 through 10 in the Tower Model
Explorer pane.
8. In the Model ribbon tab click the Run Analysis tool.
The analysis results for a 1st order analysis method appear in the Output pane.
Note: You may be asked to save file in a destination of your choice prior to analysis.
Note: At least one primary load case must be defined in order to perform an analysis.
9. In the Tower Model Explorer pane expand Analysis then click the Whole Model folder.
The analysis options for the whole model appear in the Properties pane.
10. In the Properties pane select P-Delta Analysis as the Method then select Default as the Analysis Options.
11. In the Model ribbon tab click the Run Analysis tool.
The analysis results for the new method appear in the Output pane.
12. In the Model ribbon tab click the Check Code tool.
The code check operations appear in the Output pane.

Reviewing Results and Creating Reports


Using the EIA/TIA-222-F code.
1. In the Tower Model Explorer pane expand Analysis > Whole Model > Results > Displacement Results ,
then click the Node Displacements folder.
The node displacement table appears in the Output pane.
2. In the Tower Model Explorer pane expand Analysis > Whole Model > Results > Displacement Results >
Deflected Profile , then click the Horizontal Deflection folder.
The horizontal deflection graph appears in the Properties pane.
3. In the Results ribbon tab select Primary LoadCase 2 from the drop-down menu.
STAAD(X) Tower

Tutorials

Monopole Tower per TIA-222-F


Reviewing Results and Creating Reports
The horizontal deflection graph for the selected primary load case appears in the Properties pane.
4. In the Tower Model Explorer pane expand Analysis > Whole Model > Results > Force Results > Linear
Members , then click on the Member End Forces folder.
The member end force table appears in the Output pane.
5. In the Tower Model Explorer pane expand Analysis > Results > Force Results > Linear Members , then
click the Forces/Displacements folder.
6.
In the Model ribbon tab click the Select Physical Member icon
then click on any member of the
model in the View pane.
The Results: Physical Member dialog appears and the properties appear in the Properties pane for the
member you selected.
7. In the Tower Model Explorer pane expand Analysis > Whole Model > Results > Force Results > Linear
Members , then click the Member Force Graphs folder and then on a physical member in the View pane.
The member force graph for the member you selected appears in the Output pane.
8. In the Tower Model Explorer pane expand Analysis > Whole Model > Results > Force Results > Leg
Compression Curves , then click on the Leg A folder.
A diagram of the axial compression along Leg A's height appears in the Properties pane.
9. In the Results ribbon tab click the Axial Force, Shear Y Force, Shear Z Force, Torsion, Bending
Moment Y, Bending Moment Z, Displacement, Beam Stress, and Support Reaction tools one at a time.
They will become highlighted.
The diagrams for each highlighted option will appear in the View pane, respectively.
Tip: The force diagrams in the View pane can be turned off by clicking the respective tools again,
unhighlighting them.
Note: All of the force values can be viewed simultaneously in a table by going to the Tower
Model Explorer pane and expanding Analysis > Whole Model > Results > Reaction Results ,
then clicking on the Reactions folder. The support reactions table appears in the Output pane.
10. In the Results ribbon tab select Primary LoadCase 5 from the drop-down menu, then highlight the Axial
Force tool and the Displacement tool.
The force and displacement diagrams appear on the model in the View pane.
Note: All forces shown in the View pane are for the primary load case that is selected in the
Results ribbon tab.
11. Click the Report ribbon tab.
The Report Document Map and Selected Item List panes replace the previous panes.
12. In the Report Document Map pane expand Reports > Input Data , then click and drag the Analytical
section-wise Pressure and Force item into the Selected Item List pane, as well as the Reference Load
Cases item.
Tip: While hovering in the Selected Item List pane, a red line appears to indicate where the item
will be placed.
Tip: Items in the Selected Item List pane can be rearranged by clicking and dragging them into a
new position.
13.

Click on the Generate Report icon


in the Selected Item List pane.
A report including data from your item appears in the View pane.
14. In the Model ribbon tab click the Save tool.
The Save Template dialog appears.
15. Type mon_tower1 report as the Template Name:, then click OK.

STAAD(X) Tower

10

Tutorials

Monopole Tower Per TIA-222-G

Monopole Tower TIA-222-G


Please note that the purpose of this tutorial is to demonstrate the general functions and locations of the tools
available in STAAD(X).Tower . For further explanations and details that are not included in this tutorial,
please refer to the User's Manual.

Creating a New Monopole Tower


Using the TIA-222-G code.
1. After launching STAAD(X) Tower, select New from the Start ribbon tab.
The STAAD(X) Tower dialog appears.
2. Select Monopole as the type of tower, then click Next >.
The Setup Wizard dialog appears.
3. Click Next > to proceed to the Tower Properties page.
4. Input the following into the Tower Properties page:
General Tower Properties

Input

Tower Name

Tapered Monopole Ex TIA222G

Unit Type

Metric

Country Code

US

Design Code

TIA-222-G

Length Unit and Force Unit

m and kN

Monopole Tower Properties

Input

Type of Monopole

Tapered

Elevation At Base (m)

Height of Tower (m)

40

Number of Sections

Number of Sides

OctDecagonal (18)

Round Monopole Extension

(unchecked)

Click Next > to proceed to the Structural Properties page.


5. Input the following into the Structural Properties page:

STAAD(X) Tower

11

Tutorials

Monopole Tower per TIA-222-G


Creating a New Monopole Tower
Member Properties

Input

Type of section

Tapered Tube

Depth/Dia of Tube at top (mm)

200

Tube Thickness at top (mm)

Tube Thickness at base (mm)

Galvanizing Thickness (mm)

Tapered Factor (mm/m)

20.4

Material and Grade

Steel and A572 Gr. 65

Type of support

Fixed

Apply self-weight load

(checked)

Factor and Direction

-1 and Y

Click Next > and then click OK.


This exits you out of the Setup Wizard and brings you to the main work area.
6. In the Tower Model Explorer pane expand Physical Model > Objects , then right click the Sections folder
and select Show Tapered Pole Sections Table from the pop-up menu.
The tapered pole sections table appears in the Output pane where edits can be made.
7. Input the following in the Output pane:
Section ID

Length (ft)

Lap Splice (ft)

Thickness

10

0.75

10

10

1.25

13

Tip: The length for Section ID 4 will automatically adjust according to the other lengths and lap
splice values; therefore, enter the first three lengths and the lap splices first. The fourth section
will automatically become 12.5 m.
Note: The thickness column will automatically round your values to two decimal places. The
thickness column will calculate the thickness for intermediate sections based on the linear
interpolation of the thicknesses defined for top and bottom sections. You can edit the thickness
as per the required information.
Tip: You can further edit the tower by looking in the Tower Model Explorer pane and expanding
Physical Model > Objects > Sections . Clicking on each section will show its properties in the
Properties pane where edits can be made.
8. In the Model ribbon tab click the Save tool.
Your work so far has been saved. You may be prompted to save the file in a destination of your choice.

STAAD(X) Tower

12

Tutorials

Monopole Tower per TIA-222-G


Adding Components

Adding Components
Using the TIA-222-G code.
1. In the Components ribbon tab click the Low Profile Platform tool.
A new Mount 1 appears in the Tower Model Explorer pane, the mount appears on the model in the View
pane, and the its properties appear in the Properties pane.
2. In the Properties pane input 38 m as the Elevation.
3. In the Tower Model Explorer pane expand Mount 1 then click Low Profile Platform 38m.
The low profile platform's properties appear in the Properties pane.
4. Input the following into the Properties pane:
Low Profile Platform Properties

Input

Width of Platform

3 m

No. of Mount Pipe: Face A

No. of Mount Pipe: Face B

No. of Mount Pipe: Face C

5. In the Components ribbon tab click the Pipe/Dish Mount tool.


A new Mount 2 appears in the Tower Model Explorer pane, the mount appears on the model in the View
pane, and its properties appear in the Properties pane.
6. In the Properties pane, input 32 m as the Elevation.
7. In the Tower Model Explorer pane expand Mount 2 then click Mount Pipe 11.
More of the mount pipe's properties appear in the Properties pane.
8. Input the following into the Properties pane:
Mount Pipe Properties

Input

Orientation

Leg A

Vertical

33.00 mm

9. In the Tower Model Explorer pane expand Mount Pipe 11 and click on Antenna 11-Panel.
The antenna's properties appear in the Properties pane.
10. Input the Following into the Properties pane:
Appurtenance Properties

Input

Antenna Type

Dish

Dish Type

Parabola without Radome

The panel antenna on the model is changed to a dish antenna in the View pane, and Antenna 11-Panel
changes to Antenna 11-Dish in the Tower Model Explorer pane.
11. In the Components ribbon tab click the Feedlines tool.
A new FeedLine 1 appears in the Tower Model Explorer pane, a feedline appears on the model in the
View pane, and its properties appear in the Properties pane.
12. Input the following into the Properties pane:

STAAD(X) Tower

13

Tutorials

Monopole Tower per TIA-222-G


Adding Loads
Feedline Properties

Input

Coax Cable

EW52

Start Height

1 m

End Height

33 m

No. of Lines (Coaxes)

Tip: End Height must be entered before Start Height.


13. To edit or add supports, go to the Tower Model Explorer Pane and expand Physical Model and right click
on the Supports folder. You can add the type of support desired by selecting it from the pop-up menu.
The restraint options for the support selected appear in the Properties pane and can be edited.
Note: For this model, a fixed support was assigned in the Setup Wizard and can be seen if the
Supports folder is expanded.
14. In the Model ribbon tab click the Save tool.
Your work so far has been saved. You may be prompted to save the file in a destination of your choice.

Adding Loads
Using the TIA-222-G code.
1. In the Tower Model Explorer pane expand Physical Model > Loads then right click on the Load
Generation Parameters folder and select Add Wind/Ice Parameters from the pop-up menu then TIA/
EIA[222G] Definition from its pop-up menu.
A new TIA/EIA[222G] Load Def. 1 appears in the Tower Model Explorer pane and its properties appear
in the Properties pane.
2. Input the following into the Properties pane:
Zone Identification

Input

State

Alabama

County

Coffee

Note: Wind speed and ice thickness have been automatically updated to reflect the inputted
location.
Expand the Load Cases drop-down menu and check the boxes next to all of the load cases.
The six new load cases have been added as Load Groups 2 through 7 in the Tower Model Explorer pane.
3. Expand each of the new Load Groups, then right click on each of their wind/ice loads and select Assign
from their pop-up menus, respectively.
The white boxes next to the wind/ice loads will turn green once they have been assigned and you will see
the loads applied in the View pane, respectively. The new loads have been assigned to the entire structure.
Note: Three new load groups will appear as Load Groups 11 through 13.
4. In the Model ribbon tab click the Save tool.
Your work so far has been saved. You may be prompted to save the file in a destination of your choice.

Primary Load Cases and Analysis


Using the TIA-222-G code.

STAAD(X) Tower

14

Tutorials

Monopole Tower per TIA-222-G


Primary Load Cases and Analysis
1. In the Tower Model Explorer pane expand Analysis > Whole Model > Load Cases , then right click the
Primary folder and select Primary Load Case Generator from the pop-up menu.
The Primary Load Case Generator dialog appears.
2. In the Primary Load Case Generator dialog, check the following options:
Primary Load Case
1.2 Dead + 1.6 Wind 0 degree
1.2 Dead + 1.6 Wind 45 degree
1.2 Dead + 1.6 Wind 90 degree
1 Dead + 1 Wind service 0 degree
1 Dead + 1 Wind service 45 degree
1 Dead + 1 Wind service 90 degree

3.

4.
5.
6.
7.

Click OK. The six new primary load cases have been added as Primary LoadCases 1 through 6 in the
Tower Model Explorer pane.
In the Tower Model Explorer pane expand Analysis > Whole Model > Load Cases , then right click the
Primary folder and select Add Primary Load Case from the pop-up menu.
A new Primary LoadCase 7 appears in the Tower Model Explorer pane and the load case editor appears
in the Properties pane.
In the Properties pane click the drop-down menu next to Load Group Type and check Select All.
The load groups appear in the Properties pane.
Click 1:Load Group 1, input 1.2 as the Factor, then click Add.
The load group with its assigned factor appears in the Properties pane under Selected Load Groups.
Click 2:Load Group 2, input 1.6 as the Factor, then click Add.
The load group with its assigned factor appears in the Properties pane under Selected Load Groups.
Repeat steps 3 through 6 to create the following primary load cases:
Primary LoadCase Number

Load Groups and Factors

1:Load Group 1 (1.2) + 3:Load Group 3 (1.6)

1:Load Group 1 (1.2) + 4:Load Group 4 (1.6)

10

1:Load Group 1 (0.9) + 7:Load Group 7 (1.6)

The three new load cases have been added as Primary LoadCases 8 through 10 in the Tower Model
Explorer pane.
8. In the Model ribbon tab click the Run Analysis tool.
The analysis results for a 1st order analysis method appear in the Output pane.
Note: You may be asked to save file in a destination of your choice prior to analysis.
Note: At least one primary load case must be defined in order to perform an analysis.
9. In the Tower Model Explorer pane, expand Analysis then click the Whole Model folder.
The analysis options for the whole model appear in the Properties pane.
10. In the Properties pane select P-Delta Analysis as the Method then select Default as the Analysis Options.
11. In the Model ribbon tab click the Run Analysis tool.
The analysis results for the new method appear in the Output pane.
STAAD(X) Tower

15

Tutorials

Monopole Tower per TIA-222-G


Reviewing Results and Creating Reports
12. In the Model ribbon tab click the Check Code tool.
The code check operations appear in the Output pane.

Reviewing Results and Creating Reports


Using the TIA-222-G code.
1. In the Tower Model Explorer pane expand Analysis > Whole Model > Results > Displacement Results ,
then right click the Node Displacements folder and select Show Joint Displacement Table from the popup menu.
The node displacement results table appears in the Output pane.
2. In the Tower Model Explorer pane expand Analysis > Whole Model > Results > Displacement Results >
Deflected Profile , then click the Horizontal Deflection folder.
The horizontal deflection graph appears in the Properties pane.
3. In the Results ribbon tab select Primary Load Case 2 from the drop-down menu.
The deflected profile results for Primary Load Case 2 appear in the Properties pane.
4. In the Tower Model Explorer pane expand Analysis > Whole Model > Results > Force Results > Linear
Members , then click on the Member End Forces folder.
The member end force results table appears in the Output pane.
5. In the Tower Model Explorer pane expand Analysis > Whole Model > Results > Force Results > Linear
Members , then click the Forces/Displacements folder.
6.
In the Model ribbon tab click the Select Physical Member icon
then click on any physical member on
the tower in the View pane.
The Results: Physical Member dialog appears and the properties appear in the Properties pane for the
member you selected.
7. In the Tower Model Explorer pane expand Analysis > Whole Model > Results > Force Results > Linear
Members , then click the Member Force Graphs folder and then on a physical member in the View pane.
The member force graph for the member you selected appears in the Output pane.
8. In the Tower Model Explorer pane expand Analysis > Whole Model > Results > Force Results > Leg
Compression Curves , then click on the Leg A folder.
A diagram of the axial compression along Leg A's height appears in the Properties pane.
9. In the Results ribbon tab click the Axial Force, Shear Y Force, Shear Z Force, Torsion, Bending
Moment Y, Bending Moment Z, Displacement, Beam Stress, and Support Reaction tools one at a time.
They will become highlighted.
The diagrams for each highlighted option will appear in the View pane, respectively.
Tip: The force diagrams in the View pane can be turned off by clicking the respective tools,
unhighlighting them.
Note: All of the force values can be viewed simultaneously in a table by going to the Tower
Model Explorer pane and expanding Analysis > Whole Model > Results > Reaction Results ,
then clicking on the Reactions folder. The support reactions table appears in the Output pane.
10. In the Results ribbon tab select Primary LoadCase 5 from the drop-down menu, then highlight the Axial
Force tool and the Displacement tool.
The force and displacement diagrams appear on the model in the View pane.
Note: All forces shown in the View pane are for the primary load case that is selected in the
Results ribbon tab.
11. Click the Report ribbon tab.
The Report Document Map and Selected Item List panes replace the previous panes.
12. In the Report Document Map pane expand Reports > Input Data , then click and drag the Analytical
section-wise Pressure and Force item into the Selected Item List pane, as well as the Reference Load
Cases item.

STAAD(X) Tower

16

Tutorials

Monopole Tower per TIA-222-G


Reviewing Results and Creating Reports
Tip: While hovering in the Selected Item List pane, a red line appears to indicate where the item
will be placed.
Tip: Items in the Selected Item List pane can be rearranged by clicking and dragging them into a
new position.
13.

Click on the Generate Report icon


in the Selected Item List pane.
A report including data from your item appears in the View pane.

STAAD(X) Tower

17

Tutorials

Monopole Tower per TIA-222-G


Reviewing Results and Creating Reports

STAAD(X) Tower

18

Tutorials

Monopole Tower Per TIA-222-G With IS:875 Loads

Monopole Tower TIA-222-G


Using IS:875 loads.
Please note that the purpose of this tutorial is to demonstrate the general functions and locations of the tools
available in STAAD(X).Tower . For further explanations and details that are not included in this tutorial,
please refer to the User's Manual.

Creating a New Monopole Tower


Using IS:875 loads.
1. After launching STAAD(X) Tower, select New from the Start ribbon tab.
The STAAD(X) Tower dialog appears.
2. Select Monopole as the type of tower, then click Next >.
The Setup Wizard dialog appears.
3. Click Next > to proceed to the Tower Properties page.
4. Input the following into the Tower Properties page:
General Tower Properties

Input

Tower Name

Tapered Monopole Ex TIA222G 2

Unit Type

Metric

Country Code

US

Design Code

TIA-222-G

Length Unit and Force Unit

m and kN

Monopole Tower Properties

Input

Type of Monopole

Tapered

Elevation At Base (m)

Height of Tower (m)

40

Number of Sections

Number of Sides

OctDecagonal (18)

Round Monopole Extension

(unchecked)

Click Next > to proceed to the Structural Properties page.


5. Input the following into the Structural Properties page:

STAAD(X) Tower

19

Tutorials

Monopole Tower per TIA-222-G with IS:875 Loads


Creating a New Monopole Tower
Member Properties

Input

Type of section

Tapered Tube

Depth/Dia of Tube at top (mm)

200

Tube Thickness at top (mm)

Tube Thickness at base (mm)

Galvanizing Thickness (mm)

Tapered Factor (mm/m)

20.4

Material and Grade

Steel and A572 Gr. 65

Type of support

Fixed

Apply self-weight load

(checked)

Factor and Direction

-1 and Y

Click Next > and then click OK.


This exits you out of the Setup Wizard and brings you to the main work area.
6. In the Tower Model Explorer pane expand Physical Model > Objects , then right click the Sections folder
and select Show Tapered Pole Sections Table from the pop-up menu.
The tapered pole sections table appears in the Output pane where edits can be made.
7. Input the following in the Output pane:
Section ID

Length (ft)

Lap Splice (ft)

Thickness

10

0.75

10

10

1.25

13

Tip: The length for Section ID 4 will automatically adjust according to the other lengths and lap
splice values; therefore, enter the first three lengths and the lap splices first. The fourth section
will automatically become 12.5 m.
Note: The thickness column will automatically round your values to two decimal places. The
thickness column will calculate the thickness for intermediate sections based on the linear
interpolation of the thicknesses defined for top and bottom sections. You can edit the thickness
as per the required information.
Tip: You can further edit the tower by looking in the Tower Model Explorer pane and expanding
Physical Model > Objects > Sections . Clicking on each section will show its properties in the
Properties pane where edits can be made.
8. In the Model ribbon tab click the Save tool.
Your work so far has been saved. You may be prompted to save the file in a destination of your choice.

STAAD(X) Tower

20

Tutorials

Monopole Tower per TIA-222-G with IS:875 Loads


Adding Components

Adding Components
Using IS:875 loads.
1. In the Components ribbon tab click the Low Profile Platform tool.
A new Mount 1 appears in the Tower Model Explorer pane, the mount appears on the model in the View
pane, and the its properties appear in the Properties pane.
2. In the Properties pane input 38 m as the Elevation.
3. In the Tower Model Explorer pane expand Mount 1 then click Low Profile Platform 38m.
The low profile platform's properties appear in the Properties pane.
4. Input the following into the Properties pane:
Low Profile Platform Properties

Input

Width of Platform

3 m

No. of Mount Pipe: Face A

No. of Mount Pipe: Face B

No. of Mount Pipe: Face C

5. In the Components ribbon tab click the Pipe/Dish Mount tool.


A new Mount 2 appears in the Tower Model Explorer pane, the mount appears on the model in the View
pane, and its properties appear in the Properties pane.
6. In the Properties pane, input 32 m as the Elevation.
7. In the Tower Model Explorer pane expand Mount 2 then click Mount Pipe 11.
More of the mount pipe's properties appear in the Properties pane.
8. Input the following into the Properties pane:
Mount Pipe Properties

Input

Orientation

Leg A

Vertical

33.00 mm

9. In the Tower Model Explorer pane expand Mount Pipe 11 and click on Antenna 11-Panel.
The antenna's properties appear in the Properties pane.
10. Input the Following into the Properties pane:
Appurtenance Properties

Input

Antenna Type

Dish

Dish Type

Parabola without Radome

The panel antenna on the model is changed to a dish antenna in the View pane, and Antenna 11-Panel
changes to Antenna 11-Dish in the Tower Model Explorer pane.
11. In the Components ribbon tab click the Feedlines tool.
A new FeedLine 1 appears in the Tower Model Explorer pane, a feedline appears on the model in the
View pane, and its properties appear in the Properties pane.
12. Input the following into the Properties pane:

STAAD(X) Tower

21

Tutorials

Monopole Tower per TIA-222-G with IS:875 Loads


Adding Loads
Feedline Properties

Input

Coax Cable

EW52

Start Height

1 m

End Height

33 m

No. of Lines (Coaxes)

Tip: End Height must be entered before Start Height.


13. To edit or add supports, go to the Tower Model Explorer Pane and expand Physical Model and right click
on the Supports folder. You can add the type of support desired by selecting it from the pop-up menu.
The restraint options for the support selected appear in the Properties pane and can be edited.
Note: For this model, a fixed support was assigned in the Setup Wizard and can be seen if the
Supports folder is expanded.
14. In the Model ribbon tab click the Save tool.
Your work so far has been saved. You may be prompted to save the file in a destination of your choice.

Adding Loads
Using IS:875 loads.
1. In the Tower Model Explorer pane expand Physical Model > Loads then right click on the Load
Generation Parameters folder and select Add Wind/Ice Parameters from the pop-up menu then IS:875
Definition from its pop-up menu.
A new Wind/Ice Load Def.(IS:875):1 appears in the Tower Model Explorer pane and its properties
appear in the Properties pane.
2. In the Properties pane select Almora as the City/Town.
Note: Wind speed and gust factor have been automatically updated to reflect the inputted
location.
Terrain, Height, Structure Size Factor [k2]

Input

Terrain Category

Category 2

Structure Classification

Expand the Load Cases drop-down menu and check the boxes next to all of the load cases.
The nine new load cases have been added as Load Groups 2 through 10 in the Tower Model Explorer
pane.
3. Expand each of the new Load Groups, then right click on each of their wind/ice loads and select Assign
from their pop-up menus, respectively.
The white boxes next to the wind/ice loads will turn green once they have been assigned and you will see
the loads applied in the View pane, respectively. The new loads have been assigned to the entire structure.
Note: Three new load groups will appear as Load Groups 11 through 13.
4. In the Model ribbon tab click the Save tool.
Your work so far has been saved. You may be prompted to save the file in a destination of your choice.

Primary Load Cases and Analysis


Using IS:875 loads.
STAAD(X) Tower

22

Tutorials

Monopole Tower per TIA-222-G with IS:875 Loads


Reviewing Results and Creating Reports
1. In the Tower Model Explorer pane expand Analysis > Whole Model > Load Cases , then right click the
Primary folder and select Add Primary Load Case from the pop-up menu.
A new Primary LoadCase 1 appears in the Tower Model Explorer pane and the load case editor appears
in the Properties pane.
2. In the Properties pane click the drop-down menu next to Load Group Type and check Select All.
The load groups appear in the Properties pane.
3. Click 1:Load Group 1, input 1.2 as the Factor, then click Add.
The load group with its assigned factor appears in the Properties pane under Selected Load Groups.
4. Click 2:Load Group 2, input 1.6 as the Factor, then click Add.
The load group with its assigned factor appears in the Properties pane under Selected Load Groups.
5. Repeat steps 1 through 4 to create the following primary load cases:
Primary LoadCase Number

Load Groups and Factors

1:Load Group 1 (1.2) + 3:Load Group 3 (1.6)

1:Load Group 1 (1.2) + 4:Load Group 4 (1.6)

1:Load Group 1 (0.9) + 9:Load Group 9 (1.6)

1:Load Group 1 (0.9) + 10:Load Group 10


(1.6)

1:Load Group 1 (0.9) + 11:Load Group 11


(1.6)

The five new load cases have been added as Primary LoadCases 2 through 6 in the Tower Model
Explorer pane.
6. In the Model ribbon tab click the Run Analysis tool.
The analysis results for a 1st order analysis method appear in the Output pane.
Note: You may be asked to save file in a destination of your choice prior to analysis.
Note: At least one primary load case must be defined in order to perform an analysis.
7. In the Tower Model Explorer pane expand Analysis then click the Whole Model folder.
The analysis options for the whole model appear in the Properties pane.
8. In the Properties pane select P-Delta Analysis as the Method then select Default as the Analysis Options.
9. In the Model ribbon tab click the Run Analysis tool.
The analysis results for the new method appear in the Output pane.
10. In the Model ribbon tab click the Check Code tool.
The code check operations appear in the Output pane.

Reviewing Results and Creating Reports


Using IS:875.
1. In the Tower Model Explorer pane expand Analysis > Whole Model > Results > Displacement Results ,
then right click the Node Displacements folder and select Show Joint Displacement Table from the popup menu.
The node displacement results table appears in the Output pane.
2. In the Tower Model Explorer pane expand Analysis > Whole Model > Results > Displacement Results >
Deflected Profile , then click the Horizontal Deflection folder.
The horizontal deflection graph appears in the Properties pane.
3. In the Results ribbon tab select Primary Load Case 2 from the drop-down menu.
STAAD(X) Tower

23

Tutorials

Monopole Tower per TIA-222-G with IS:875 Loads


Reviewing Results and Creating Reports
The deflected profile results for Primary Load Case 2 appear in the Properties pane.
4. In the Tower Model Explorer pane expand Analysis > Whole Model > Results > Force Results > Linear
Members , then click on the Member End Forces folder.
The member end force results table appears in the Output pane.
5. In the Tower Model Explorer pane expand Analysis > Whole Model > Results > Force Results > Linear
Members , then click the Forces/Displacements folder.
6.
In the Model ribbon tab click the Select Physical Member icon
then click on any physical member on
the tower in the View pane.
The Results: Physical Member dialog appears and the properties appear in the Properties pane for the
member you selected.
7. In the Tower Model Explorer pane expand Analysis > Whole Model > Results > Force Results > Linear
Members , then click the Member Force Graphs folder and then on a physical member in the View pane.
The member force graph for the member you selected appears in the Output pane.
8. In the Tower Model Explorer pane expand Analysis > Whole Model > Results > Force Results > Leg
Compression Curves , then click on the Leg A folder.
A diagram of the axial compression along Leg A's height appears in the Properties pane.
9. In the Results ribbon tab click the Axial Force, Shear Y Force, Shear Z Force, Torsion, Bending
Moment Y, Bending Moment Z, Displacement, Beam Stress, and Support Reaction tools one at a time.
They will become highlighted.
The diagrams for each highlighted option will appear in the View pane, respectively.
Tip: The force diagrams in the View pane can be turned off by clicking the respective tools,
unhighlighting them.
Note: All of the force values can be viewed simultaneously in a table by going to the Tower
Model Explorer pane and expanding Analysis > Whole Model > Results > Reaction Results ,
then clicking on the Reactions folder. The support reactions table appears in the Output pane.
10. In the Results ribbon tab select Primary LoadCase 5 from the drop-down menu, then highlight the Axial
Force tool and the Displacement tool.
The force and displacement diagrams appear on the model in the View pane.
Note: All forces shown in the View pane are for the primary load case that is selected in the
Results ribbon tab.
11. Click the Report ribbon tab.
The Report Document Map and Selected Item List panes replace the previous panes.
12. In the Report Document Map pane expand Reports > Input Data , then click and drag the Analytical
section-wise Pressure and Force item into the Selected Item List pane, as well as the Reference Load
Cases item.
Tip: While hovering in the Selected Item List pane, a red line appears to indicate where the item
will be placed.
Tip: Items in the Selected Item List pane can be rearranged by clicking and dragging them into a
new position.
13.

Click on the Generate Report icon


in the Selected Item List pane.
A report including data from your item appears in the View pane.

STAAD(X) Tower

24

Tutorials

Self-Supporting Tower Per TIA-222-F

Self-Supporting Tower EIA/TIA-222-F


Please note that the purpose of this tutorial is to demonstrate the general functions and locations of the tools
available in STAAD(X).Tower . For further explanations and details that are not included in this tutorial,
please refer to the User's Manual.

Creating a New Self-Supporting Tower


Using the EIA/TIA-222-F code.
1. After launching STAAD(X) Tower, select New from the Start ribbon tab.
The STAAD(X) Tower dialog appears.
2. Select Self-Supporting as the type of tower, then click Next >.
The Setup Wizard dialog appears.
3. Click Next > to proceed to the Tower Properties page.
4. Input the following into the Tower Properties page:
General Tower Properties

Input

Tower Name

Self Supporting Tower Ex TIA222F

Type of Unit

English

Country Code

US

Design Code

EIA/TIA-222-F

Length Unit

ft

Force Unit

kip

Base Tower Properties

Input

No. of Legs

4 Leg

Elevation At Base and Height of Tower

0 and 150

Base Face Width and Top Face Width

18.5 and 4.5

Constant Slope

(unchecked)

Type of Configuration

Sections

No. of Sections and Bays/Section

8 and 2

Default Bracing and Horizontals

X Brace and (checked)

Click Next > to proceed to the Structural Properties page.


STAAD(X) Tower

25

Tutorials

Self-Supporting Tower per TIA-222-F


Editing the Properties
5. Input the following in to the Structural Properties page:
Member Properties

Input

Specification and Shape (Leg Members)

AISC:9 Edition:Generic and Round Bar

Designation and Steel Grade (Leg Members)

RB2 and A572 Gr.50

Specification and Shape (Horizontal Members)

AISC:9 Edition:Generic and L

Designation and Steel Grade (Horizontal Members) L2X2X3/16 and A572 Gr.50
Specification and Shape (Diagonal Members)

AISC:9 Edition:Generic and L

Designation and Steel Grade (Diagonal Members)

L2X2X3/16 and A572 Gr.50

Check the box next to Consider bracing members as Truss, select Fixed as the Support, and check the
box next to Apply Selfweight Load.
6. Click Next > and then click OK.
This exits you out of the Setup Wizard and brings you to the main work area.
7. In the Model ribbon tab click the Save tool.
Your work so far has been saved. You may be prompted to save the file in a destination of your choice.

Editing the Properties


Using the EIA/TIA-222-F code.
1. In the Tower Model Explorer pane expand Physical Model > Properties and then expand both the
Profiles and Materials folders.
The profiles and materials chosen for this model appear in the Tower Model Explorer pane.
2. In the Tools ribbon tab click the Structure Property Catalog tool.
The Structure Property Catalog dialog appears.
3. Input the following into the Structure Property Catalog dialog:
Standard

Input

Material

STEEL

Category

Hot Rolled

Country

United States

Specification

AISC:9 Edition:Generic

Profile Type

Round Bar

Country

United States

Material

STEEL

Specification

ASTM

Document

A6

Table

ASTM Steel

STAAD(X) Tower

26

Tutorials

Self-Supporting Tower per TIA-222-F


Adding Bracing
4. Click Search then scroll down and select RB2-1/2 as the designation and A36 as the Name. Then click
Add Profile + Material and close the Structure Property Catalog dialog.
The new profile and material appear in the Tower Model Explorer pane under their respective folders.
Note: Multiple profiles and materials can be added and assigned to various sections of the
model. Please refer to Example 1 for a detailed step-by-step process.
5. In the Tower Model Explorer pane expand Physical Model > Objects > Sections , then click on Section 7.
The properties for section 7 of the model appear in the Properties pane.
6. Input the following into the Properties pane:
Member Section Properties

Input

Leg

RB2-1/2

TopGirt

L2X2X3/16

Diagonal

L3X3X3/16

Horizontal

L2X2X3/16

7. In the Tower Model Explorer pane right click the Sections folder and select Show Self Supported
Sections Table from the pop-up menu.
Insert data as follows into the table that appears in the Output pane:

8. In the Model ribbon tab click the Save tool.


Your work so far has been saved. You may be prompted to save the file in a destination of your choice.

Adding Bracing
Using the EIA/TIA-222-F code.
1. In the Tools ribbon tab click the Face Bracing Wizard tool.
The Define Bracing Pattern dialog appears.
2. Input the following into the Define Bracing Pattern dialog:
Template

Input

Prototype Bracing Pattern

KBraceDown

Bracing Title

KBraceDown_Training

3. To add nodes to the bracing, input the following into the Define Bracing Pattern dialog:

STAAD(X) Tower

27

Tutorials

Self-Supporting Tower per TIA-222-F


Adding Bracing
Add

Input

Intermediate

(checked)

Intermediate Ratio

1/3

Click Add Node, then click Node 1 and Node 4 via the graphic.
A node appears on the member between Node 1 and Node 4, 1/3 of the way from the first node you
selected.
4. Add nodes to the graphic as shown by first clicking Add Node then selecting the two nodes between which
you want the new node to appear.

Note: Node numbers may vary depending on the order in which the nodes were created.
5. In the Member section of the Define Bracing Pattern dialog, select Redundant Horizontal, click Add
Member, then select the two nodes between which you want a new member to appear. Add sub-horizontal
members as shown by first clicking Add Member then selecting the two nodes between which you want
the new node to appear.

STAAD(X) Tower

28

Tutorials

Self-Supporting Tower per TIA-222-F


Adding Bracing

6. In the Member section of the Define Bracing Pattern dialog, select Redundant Diagonal, click Add
Member, then select the two nodes between which you want the new member to appear. Add diagonal
members as shown.

7. Click Update.
The Define Bracing Pattern dialog closes and the custom bracing pattern is saved.
8. In the Model ribbon tab click the Save tool.
Your work so far has been saved. You may be prompted to save the file in a destination of your choice.

STAAD(X) Tower

29

Tutorials

Self-Supporting Tower per TIA-222-F


Adding Components

Adding Components
Using the EIA/TIA-222-F code.
1. In the Components ribbon tab click the T-Frame tool.
A new Mount 1 appears in the Tower Model Explorer pane, the T-frame mount appears on the model in
the View pane, and its properties appear in the Properties pane.
2. In the Properties pane change the Elevation to 138 ft.
3. In the Components ribbon tab click the Pipe/Dish Mount tool.
A new Mount 2 appears in the Tower Model Explorer pane, the pipe/dish mount appears on the model in
the View pane, and its properties appear in the Properties pane.
4. In the Properties pane change the Elevation to 120 ft.
5. In the Components ribbon tab click the Low Profile Platform tool.
A new Mount 3 appears in the Tower Model Explorer pane, the platform appears on the model in the View
pane, and its properties appear in the Properties pane.
6. In the Properties pane change the Elevation to 110 ft.
7. In the Tower Model Explorer pane expand Mount 3 then click on Low Profile Platform 110ft.
The platform's properties appear in the Properties pane.
8. Input the following into the Properties pane:
Low Profile Platform Properties

Input

Width of Platform

12 ft

No. of Mount Pipe: Face A

No. of Mount Pipe: Face B

No. of Mount Pipe: Face C

No. of Mount Pipe: Face D

9. In the Components ribbon tab click the Ladder tool.


A new Ladder 1 appears in the Tower Model Explorer pane, the ladder appears on the model in the View
pane, and its properties appear in the Properties pane.
10. Input the following into the Properties pane:
Ladder Properties

Input

Start Height

10 ft

End Height

138 ft

Face Id

Position

Outside

Face Offset

12 in

Lateral Shift %[+/-0.5]

Note: End Height must be entered before Start Height.


11. In the Components ribbon tab click the Feedlines tool.
STAAD(X) Tower

30

Tutorials

Self-Supporting Tower per TIA-222-F


Adding Loads and Load Groups
A new Feedline 1 appears in the Tower Model Explorer pane, the feedline appears on the model in the
View pane, and its properties appear in the Properties pane.
12. Input the following into the Properites pane:
Feedline Properties

Input

Start Height

0 ft

End Height

138 ft

Along

Face

Position

Inside

Leg/Face ID:

Face Offset

8 in

Lateral Shift %[+/-0.5]

No. of Lines (Coaxes)

No. of Rows

Line Spacing

1 in

Row Spacing

0 in

13. To edit or add supports, go to the Tower Model Explorer Pane and expand Physical Model and right click
on the Supports folder. You can add the type of support desired by selecting it from the pop-up menu.
The restraint options for the support selected appear in the Properties pane and can be edited.
Note: For this model, a fixed support was assigned in the Setup Wizard and can be seen if the
Supports folder is expanded.
14. In the Model ribbon tab click the Save tool.
Your work so far has been saved. You may be prompted to save the file in a destination of your choice.

Adding Loads and Load Groups


Using the EIA/TIA-222-F code.
1. In the Tower Model Explorer pane expand Physical Model > Loads , then right click on the Load
Generation Parameters folder and select Add Wind/Ice Parameters from the pop-up menu then TIA/
EIA[222F] Definition from its pop-up menu.
A new TIA/EIA[222F] Load Def. 1 appears in the Tower Model Explorer pane and its properties appear
in the Properties pane.
2. Input the following into the Properties pane:
Zone Identification

Input

State

Washington

County

King

Check the box next to Ice Load, then expand the Load Cases drop-down menu and check the boxes next
to all of the load cases.

STAAD(X) Tower

31

Tutorials

Self-Supporting Tower per TIA-222-F


Primary Load Cases and Analysis

3.

4.

5.
6.
7.

8.

The nine new load cases have been added as Load Groups 2 through 10 in the Tower Model Explorer
pane.
Expand each of the new load groups, then right click on each of their wind/ice loads and select Assign
from their pop-up menus, respectively.
The white boxes next to the wind/ice loads will turn green once they have been assigned and you will see
the loads applied in the View pane, respectively. The new loads have been assigned to the entire structure.
In the Tower Model Explorer pane expand Physical Model > Loads > Load Groups , then right click the
Load Group 1 folder and select Joint Load from the pop-up menu then Add Joint Load from its pop-up
menu.
A new Joint Load appears in the Tower Model Explorer pane and its properties appear in the Properties
pane.
In the Properties pane enter -1 kip for Fy.
In the Model ribbon tab click the Select Nodes icon and then select the top four nodes on the model in the
View pane.
In the Tower Model Explorer pane expand Physical Model > Loads > Load Group 1 then right click
Joint Load and select Assign from its pop-up menu.
The load group has been assigned to the nodes you selected.
In the Model ribbon tab click the Save tool.
Your work so far has been saved. You may be prompted to save the file in a destination of your choice.

Primary Load Cases and Analysis


Using the EIA/TIA-222-F code.
1. In the Tower Model Explorer pane expand Analysis > Whole Model > Load Cases then right click on the
Primary folder and select Primary Load Case Generator from the pop-up menu.
The Primary Load Case Generator dialog appears.
2. In the Primary Load Case Generator dialog, check the following options:
Primary Load Case
1 Dead + 1 Wind 0 degree
1 Dead + 1 Wind 45 degree
1 Dead + 1 Wind 90 degree
1 Dead + 1 Wind service 0 degree
1 Dead + 1 Wind service 45 degree
1 Dead + 1 Wind service 90 degree
Click OK. The six new primary load cases have been added as Primary LoadCases 1 through 6 in the
Tower Model Explorer pane.
3. In the Tower Model Explorer pane expand Analysis > Whole Model > Load Cases , then right click the
Primary folder and select Add Primary Load Case from the pop-up menu.
A new Primary LoadCase 7 appears in the Tower Model Explorer pane and the load case editor appears
in the Properties pane.
4. In the Properties pane click the drop-down menu next to Load Group Type and check Select All.
The load groups appear in the Properties pane.
5. Click 1:Load Group 1, input 1.2 as the Factor, then click Add.
The load group with its assigned factor appears in the Properties pane under Selected Load Groups.
STAAD(X) Tower

32

Tutorials

Self-Supporting Tower per TIA-222-F


Reviewing Results and Creating Reports
6. Click 2:Load Group 2, input 1.6 as the Factor, then click Add.
The load group with its assigned factor appears in the Properties pane under Selected Load Groups.
7. Repeat steps 3 through 6 to create the following primary load cases:
Primary LoadCase Number

Load Groups and Factors

1:Load Group 1 (1.2) + 3:Load Group 3 (1.6)

1:Load Group 1 (1.2) + 4:Load Group 4 (1.6)

10

1:Load Group 1 (0.9) + 9:Load Group 9 (1.6)

The three new load cases have been added as Primary LoadCases 8 through 10 in the Tower Model
Explorer pane.
8. In the Model ribbon tab click the Run Analysis tool.
The analysis results for a 1st order analysis method appear in the Output pane.
Note: You may be asked to save file in a destination of your choice prior to analysis.
Note: At least one primary load case must be defined in order to perform an analysis.
9. In the Tower Model Explorer pane expand Analysis then click the Whole Model folder.
The analysis options for the whole model appear in the Properties pane.
10. In the Properties pane select P-Delta Analysis as the Method then select Default as the Analysis Options.
11. In the Model ribbon tab click the Run Analysis tool.
The analysis results for the new method appear in the Output pane.
12. In the Model ribbon tab click the Check Code tool.
The code check operations appear in the Output pane.

Reviewing Results and Creating Reports


Using the EIA/TIA-222-F code.
1. In the Model ribbon tab select TIA-222-F as the Active Design Code.
2. In the Model ribbon tab click the Check Slenderness tool.
Any members which do not meet slenderness criteria per the selected code appear in the Output pane.
Tip: Selecting an entry in the Output pane will highlight the correlating member in the View pane.
3. In the Results ribbon tab click the Show All Results tool.
The design results appear in the Output pane. Members that have failed the design check are highlighted in
the View pane.
4. In the Results ribbon tab click the Show Selective Result tool then select any physical member.
Design results for the selected physical member appear in the Output pane.
5. Click the Report ribbon tab.
The Report Document Map and Selected Item List panes replace the previous panes.
6. In the Report Document Map pane expand Reports > Input Data , then click and drag the Section
Information item into the Selected Item List pane, as well as the Member Specification item.
Tip: While hovering in the Selected Item List pane, a red line appears to indicate where the item
will be placed.
Tip: Items in the Selected Item List pane can be rearranged by clicking and dragging them into a
new position.
7.

in the Selected Item List pane.


Click on the Generate Report icon
A report including data from your item appears in the View pane.

STAAD(X) Tower

33

Tutorials

Self-Supporting Tower per TIA-222-F


Reviewing Results and Creating Reports

STAAD(X) Tower

34

Tutorials

Self-Supporting Tower Per TIA-222-G

Self-Supporting Tower TIA-222-G


Please note that the purpose of this tutorial is to demonstrate the general functions and locations of the tools
available in STAAD(X).Tower . For further explanations and details that are not included in this tutorial,
please refer to the User's Manual.

Creating a New Self-Supporting Tower


Using the TIA-222-G code.
1. After launching STAAD(X) Tower, select New from the Start ribbon tab.
The STAAD(X) Tower dialog appears.
2. Select Self-Supporting as the type of tower, then click Next >.
The Setup Wizard dialog appears.
3. Click Next > to proceed to the Tower Properties page.
4. Input the following into the Tower Properties page:
General Tower Properties

Input

Tower Name

Self Supporting Tower Ex TIA222G

Type of Unit

Metric

Country Code

US

Design Code

TIA-222-G

Length Unit

Force Unit

kN

Base Tower Properties

Input

No. of Legs

4 Leg

Elevation At Base and Height of Tower

0 and 46

Base Face Width and Top Face Width

5.5 and 1.4

Constant Slope

(unchecked)

Type of Configuration

Sections

No. of Sections and Bays/Section

8 and 2

Default Bracing and Horizontals

X Brace and (checked)

Click Next > to proceed to the Structural Properties page.


STAAD(X) Tower

35

Tutorials

Self-Supporting Tower per TIA-222-G


Editing the Properties
5. Input the following in to the Structural Properties page:
Member Properties

Input

Specification and Shape (Leg Members)

AISC Metric:13 Edition:Generic and PIPE

Designation and Steel Grade (Leg Members)

Pipe75STD and A572 Gr.50

Specification and Shape (Horizontal Members)

AISC Metric:13 Edition:Generic and L

Designation and Steel Grade (Horizontal Members) L64X64X4.8 and A572 Gr.50
Specification and Shape (Diagonal Members)

AISC Metric:13 Edition:Generic and L

Designation and Steel Grade (Diagonal Members)

L51X51X4.8 and A572 Gr.50

Check the box next to Consider bracing members as Truss, select Fixed as the Support, and check the
box next to Apply Selfweight Load.
6. Click Next > and then click OK.
This exits you out of the Setup Wizard and brings you to the main work area.
7. In the Model ribbon tab click the Save tool.
Your work so far has been saved. You may be prompted to save the file in a destination of your choice.

Editing the Properties


Using the TIA-222-G code.
1. In the Tower Model Explorer pane expand Physical Model > Properties and then expand both the
Profiles and Materials folders.
The profiles and materials chosen for this model appear in the Tower Model Explorer pane.
2. In the Tools ribbon tab click the Structure Property Catalog tool.
The Structure Property Catalog dialog appears.
3. Input the following into the Structure Property Catalog dialog:
Standard

Input

Material

STEEL

Category

Hot Rolled

Country

United States

Specification

AISC Metric:13 Edition:Generic

Profile Type

PIPE

Country

United States

Material

STEEL

Specification

ASTM

Document

A6

Table

ASTM Steel

STAAD(X) Tower

36

Tutorials

Self-Supporting Tower per TIA-222-G


Adding Bracing
4. Click Search then scroll down and click Pipe89STD as the designation and A53 Gr.8 as the Name. Then
click Add Profile + Material and close the Structure Property Catalog dialog.
The new profile and material appear in the Tower Model Explorer pane under their respective folders.
Note: Multiple profiles and materials can be added and assigned to various sections of the
model. Please refer to Example 2 for a detailed step-by-step process.
5. In the Tower Model Explorer pane expand Physical Model > Objects > Sections , then click on Section 7.
The properties for section 7 of the model appear in the Properties pane.
6. Input the following into the Properties pane:
Member Section Properties

Input

Leg

Pipe89STD

TopGirt

L64X64X4.8

Diagonal

L64X64X4.8

Horizontal

L64X64X4.8

7. In the Tower Model Explorer pane right click the Sections folder and select Show Self Supported
Sections Table from the pop-up menu.
Insert data as follows into the table that appears in the Output pane:

8. In the Model ribbon tab click the Save tool.


Your work so far has been saved. You may be prompted to save the file in a destination of your choice.

Adding Bracing
Using the TIA-222-G code.
1. In the Tools ribbon tab click the Face Bracing Wizard tool.
The Define Bracing Pattern dialog appears.
2. Input the following into the Define Bracing Pattern dialog:
Template

Input

Prototype Bracing Pattern

KBraceDown

Bracing Title

KBraceDown_Training2

3. To add nodes to the bracing, input the following into the Define Bracing Pattern dialog:

STAAD(X) Tower

37

Tutorials

Self-Supporting Tower per TIA-222-G


Adding Bracing
Add

Input

Intermediate

(checked)

Intermediate Ratio

1/3

Click Add Node, then click Node 1 and Node 4 via the graphic.
A node appears on the member between Node 1 and Node 4, 1/3 of the way from the first node you
selected.
4. Add nodes to the graphic as shown by first clicking Add Node then selecting the two nodes between which
you want the new node to appear.

Note: Node numbers may vary depending on the order in which the nodes were created.
5. In the Member section of the Define Bracing Pattern dialog, select Redundant Horizontal, click Add
Member, then select the two nodes between which you want a new member to appear. Add sub-horizontal
members as shown by first clicking Add Member then selecting the two nodes between which you want
the new node to appear.

STAAD(X) Tower

38

Tutorials

Self-Supporting Tower per TIA-222-G


Adding Bracing

6. In the Member section of the Define Bracing Pattern dialog, select Redundant Diagonal, click Add
Member, then select the two nodes between which you want the new member to appear. Add diagonal
members as shown.

7. Click Update.
The Define Bracing Pattern dialog closes and the custom bracing pattern is saved.
8. In the Model ribbon tab click the Save tool.
Your work so far has been saved. You may be prompted to save the file in a destination of your choice.

STAAD(X) Tower

39

Tutorials

Self-Supporting Tower per TIA-222-G


Adding Components

Adding Components
Using the TIA-222-G code.
1. In the Components ribbon tab click the T-Frame tool.
A new Mount 1 appears in the Tower Model Explorer pane, the T-frame mount appears on the model in
the View pane, and its properties appear in the Properties pane.
2. In the Properties pane change the Elevation to 44 m.
3. In the Components ribbon tab click the Pipe/Dish Mount tool.
A new Mount 2 appears in the Tower Model Explorer pane, the pipe/dish mount appears on the model in
the View pane, and its properties appear in the Properties pane.
4. In the Properties pane change the Elevation to 40 m.
5. In the Components ribbon tab click the Low Profile Platform tool.
A new Mount 3 appears in the Tower Model Explorer pane, the platform appears on the model in the View
pane, and its properties appear in the Properties pane.
6. In the Properties pane change the Elevation to 35 m.
7. In the Tower Model Explorer pane expand Mount 3 then click on Low Profile Platform 35m.
The platform's properties appear in the Properties pane.
8. Input the following into the Properties pane:
Low Profile Platform Properties

Input

Width of Platform

4 m

No. of Mount Pipe: Face A

No. of Mount Pipe: Face B

No. of Mount Pipe: Face C

No. of Mount Pipe: Face D

9. In the Components ribbon tab click the Ladder tool.


A new Ladder 1 appears in the Tower Model Explorer pane, the ladder appears on the model in the View
pane, and its properties appear in the Properties pane.
10. Input the following into the Properties pane:
Ladder Properties

Input

Start Height

3 m

End Height

45 m

Face Id

Position

Outside

Face Offset

200 mm

Lateral Shift %[+/-0.5]

Note: End Height must be entered before Start Height.


11. In the Components ribbon tab click the Feedlines tool.
STAAD(X) Tower

40

Tutorials

Self-Supporting Tower per TIA-222-G


Adding Loads and Load Groups
A new Feedline 1 appears in the Tower Model Explorer pane, the feedline appears on the model in the
View pane, and its properties appear in the Properties pane.
12. Input the following into the Properites pane:
Feedline Properties

Input

Start Height

0 m

End Height

45 m

Along

Face

Position

Inside

Leg/Face ID:

Face Offset

203 mm

Lateral Shift %[+/-0.5]

No. of Lines (Coaxes)

No. of Rows

Line Spacing

50 mm

Row Spacing

0 mm

13. To edit or add supports, go to the Tower Model Explorer Pane and expand Physical Model and right click
on the Supports folder. You can add the type of support desired by selecting it from the pop-up menu.
The restraint options for the support selected appear in the Properties pane and can be edited.
Note: For this model, a fixed support was assigned in the Setup Wizard and can be seen if the
Supports folder is expanded.
14. In the Model ribbon tab click the Save tool.
Your work so far has been saved. You may be prompted to save the file in a destination of your choice.

Adding Loads and Load Groups


Using the TIA-222-G code.
1. In the Tower Model Explorer pane expand Physical Model > Loads , then right click on the Load
Generation Parameters folder and select Add Wind/Ice Parameters from the pop-up menu then TIA/
EIA[222G] Definition from its pop-up menu.
A new TIA/EIA[222G] Load Def. 1 appears in the Tower Model Explorer pane and its properties appear
in the Properties pane.
2. Input the following into the Properties pane:
Zone Identification

Input

State

Washington

County

King

Expand the Load Cases drop-down menu and check the boxes next to all of the load cases.
The nine new load cases have been added as Load Groups 2 through 10 in the Tower Model Explorer
pane.
STAAD(X) Tower

41

Tutorials

Self-Supporting Tower per TIA-222-G


Primary Load Cases and Analysis
3. Expand each of the new load groups, then right click on each of their wind/ice loads and select Assign
from their pop-up menus, respectively.
The white boxes next to the wind/ice loads will turn green once they have been assigned and you will see
the loads applied in the View pane, respectively. The new loads have been assigned to the entire structure.
4. In the Tower Model Explorer pane expand Physical Model > Loads then right click the Load Generation
Parameters folder then select Add Seismic Parameters from the pop-up menu then TIA/EIA[222G]
Definition its pop-up menu.
A new TIA/EIA[222G] Seismic Def. appears in the Tower Model Explorer pane and its properties appear
in the Properties pane.
5. Input the following into the Properties pane:
Structures

Input

Classification

Class II

Ss

1.62

S1

0.55

Site Class

6. In the Tower Model Explorer pane expand Physical Model > Loads > Load Groups , then right click the
Load Group 1 folder and select Joint Load from the pop-up menu then Add Joint Load from its pop-up
menu.
A new Joint Load appears in the Tower Model Explorer pane and its properties appear in the Properties
pane.
7. In the Properties pane enter -1 kip for Fy.
8. In the Model ribbon tab click the Select Nodes icon and then select the top four nodes on the model in the
View pane.
9. In the Tower Model Explorer pane expand Physical Model > Loads > Load Group 1 then right click
Joint Load and select Assign from its pop-up menu.
The load group has been assigned to the nodes you selected.
10. In the Model ribbon tab click the Save tool.
Your work so far has been saved. You may be prompted to save the file in a destination of your choice.

Primary Load Cases and Analysis


Using the TIA-222-G code.
1. In the Tower Model Explorer pane expand Analysis > Whole Model > Load Cases then right click on the
Primary folder and select Primary Load Case Generator from the pop-up menu.
The Primary Load Case Generator dialog appears.
2. In the Primary Load Case Generator dialog, check the following options:
Primary Load Case
1.2 Dead + 1.6 Wind 0 degree
1.2 Dead + 1.6 Wind 45 degree
1.2 Dead + 1.6 Wind 90 degree
1 Dead + 1 Wind service 0 degree
1 Dead + 1 Wind service 45 degree
STAAD(X) Tower

42

Tutorials

Self-Supporting Tower per TIA-222-G


Reviewing Results and Creating Reports
Primary Load Case
1 Dead + 1 Wind service 90 degree

3.

4.
5.
6.
7.

Click OK. The six new primary load cases have been added as Primary LoadCases 1 through 6 in the
Tower Model Explorer pane.
In the Tower Model Explorer pane expand Analysis > Whole Model > Load Cases , then right click the
Primary folder and select Add Primary Load Case from the pop-up menu.
A new Primary LoadCase 7 appears in the Tower Model Explorer pane and the load case editor appears
in the Properties pane.
In the Properties pane click the drop-down menu next to Load Group Type and check Select All.
The load groups appear in the Properties pane.
Click 1:Load Group 1, input 1.2 as the Factor, then click Add.
The load group with its assigned factor appears in the Properties pane under Selected Load Groups.
Click 2:Load Group 2, input 1.6 as the Factor, then click Add.
The load group with its assigned factor appears in the Properties pane under Selected Load Groups.
Repeat steps 3 through 6 to create the following primary load cases:
Primary LoadCase Number

Load Groups and Factors

1:Load Group 1 (1.2) + 3:Load Group 3 (1.6)

1:Load Group 1 (1.2) + 4:Load Group 4 (1.6)

10

1:Load Group 1 (0.9) + 7:Load Group 7 (1.6)

The three new load cases have been added as Primary LoadCases 8 through 10 in the Tower Model
Explorer pane.
8. In the Model ribbon tab click the Run Analysis tool.
The analysis results for a 1st order analysis method appear in the Output pane.
Note: You may be asked to save file in a destination of your choice prior to analysis.
Note: At least one primary load case must be defined in order to perform an analysis.
9. In the Tower Model Explorer pane expand Analysis then click the Whole Model folder.
The analysis options for the whole model appear in the Properties pane.
10. In the Properties pane select P-Delta Analysis as the Method then select Default as the Analysis Options.
11. In the Model ribbon tab click the Run Analysis tool.
The analysis results for the new method appear in the Output pane.
12. In the Model ribbon tab click the Check Code tool.
The code check operations appear in the Output pane.

Reviewing Results and Creating Reports


Using the TIA-222-G code.
1. In the Model ribbon tab select TIA-222-G as the Active Design Code.
2. In the Model ribbon tab click the Check Slenderness tool.
Any members which do not meet slenderness criteria per the selected code appear in the Output pane.
Tip: Selecting an entry in the Output pane will highlight the correlating member in the View pane.
3. In the Results ribbon tab click the Show All Results tool.

STAAD(X) Tower

43

Tutorials

Self-Supporting Tower per TIA-222-G


Reviewing Results and Creating Reports
The design results appear in the Output pane. Members that have failed the design check are highlighted in
the View pane.
4. In the Results ribbon tab click the Show Selective Result tool then select any physical member.
Design results for the selected physical member appear in the Output pane.
5. Click the Report ribbon tab.
The Report Document Map and Selected Item List panes replace the previous panes.
6. In the Report Document Map pane expand Reports > Input Data , then click and drag the Section
Information item into the Selected Item List pane, as well as the Member Specification item.
Tip: While hovering in the Selected Item List pane, a red line appears to indicate where the item
will be placed.
Tip: Items in the Selected Item List pane can be rearranged by clicking and dragging them into a
new position.
7.

Click on the Generate Report icon


in the Selected Item List pane.
A report including data from your item appears in the View pane.

STAAD(X) Tower

44

Tutorials

Self-Supporting Tower Per IS:802 / 806

Self-Supporting Tower IS:802/806


Please note that the purpose of this tutorial is to demonstrate the general functions and locations of the tools
available in STAAD(X).Tower. For further explanations and details that are not included in this tutorial,
please refer to the User's Manual.

Creating a New Self-Supporting Tower


Using the IS:802/806 code.
1. After launching STAAD(X) Tower, select New from the Start ribbon tab.
The STAAD(X) Tower dialog appears.
2. Select Self-Supporting as the type of tower, then click Next >.
The Setup Wizard dialog appears.
3. Click Next > to proceed to the Tower Properties page.
4. Input the following into the Tower Properties page:
General Tower Properties

Input

Tower Name

Self Supporting Tower Ex IS802,806

Type of Unit

Metric

Country Code

INDIAN

Design Code

IS:802,806

Length Unit

Force Unit

kN

Base Tower Properties

Input

No. of Legs

4 Leg

Elevation At Base and Height of Tower

0 and 46

Base Face Width and Top Face Width

5.5 and 1.4

Constant Slope

(unchecked)

Type of Configuration

Sections

No. of Sections and Bays/Section

8 and 2

Default Bracing and Horizontals

X Brace and (checked)

Click Next > to proceed to the Structural Properties page.


STAAD(X) Tower

45

Tutorials

Self-Supporting Tower per IS:802 / 806


Editing the Properties
5. Input the following in to the Structural Properties page:
Member Properties

Input

Specification and Shape (Leg Members)

BIS:808 : 1989:Generic and TUBE

Designation and Steel Grade (Leg Members)

IS Tube 76.1X4.5 and YSt 240

Specification and Shape (Horizontal Members)

BIS:808 : 1989:Generic and EA

Designation and Steel Grade (Horizontal Members) ISA 50X50X6 and E 165
Specification and Shape (Diagonal Members)

BIS:808 : 1989:Generic and EA

Designation and Steel Grade (Diagonal Members)

ISA 50X50X6 and E 165

Check the box next to Consider bracing members as Truss, select Fixed as the Support, and check the
box next to Apply Selfweight Load.
6. Click Next > and then click OK.
This exits you out of the Setup Wizard and brings you to the main work area.
7. In the Model ribbon tab click the Save tool.
Your work so far has been saved. You may be prompted to save the file in a destination of your choice.

Editing the Properties


Using the IS:802/806 code.
1. In the Tower Model Explorer pane expand Physical Model > Properties and then expand both the
Profiles and Materials folders.
The profiles and materials chosen for this model appear in the Tower Model Explorer pane.
2. In the Tools ribbon tab click the Structure Property Catalog tool.
The Structure Property Catalog dialog appears.
3. Input the following into the Structure Property Catalog dialog:
Standard

Input

Material

STEEL

Category

Hot Rolled

Country

India

Specification

BIS:808 : 1989:Generic

Profile Type

TUBE

Country

India

Material

STEEL

Specification

IS

Document

2062

Table

IS Steel

STAAD(X) Tower

46

Tutorials

Self-Supporting Tower per IS:802 / 806


Adding Bracing
4. Click Search then scroll down and click IS Tube 76. as the designation, 7.33 as the A, and YSt 240 as the
Name. Then click Add Profile + Material and close the Structure Property Catalog dialog.
The new profile and material appear in the Tower Model Explorer pane under their respective folders.
Note: Multiple profiles and materials can be added and assigned to various sections of the
model. Please refer to Example 3 for a detailed step-by-step process.
5. In the Tower Model Explorer pane expand Physical Model > Objects > Sections , then click on Section 7.
The properties for section 7 of the model appear in the Properties pane.
6. Input the following into the Properties pane:
Member Section Properties

Input

Leg

IS Tube 76.1X3.2

TopGirt

IS Tube 76.1X3.2

Diagonal

IS Tube 76.1X3.2

Horizontal

IS Tube 76.1X3.2

7. In the Tower Model Explorer pane right click the Sections folder and select Show Self Supported
Sections Table from the pop-up menu.
Insert data as follows into the table that appears in the Output pane:

8. In the Model ribbon tab click the Save tool.


Your work so far has been saved. You may be prompted to save the file in a destination of your choice.

Adding Bracing
Using the IS:802/806 code.
1. In the Tools ribbon tab click the Face Bracing Wizard tool.
The Define Bracing Pattern dialog appears.
2. Input the following into the Define Bracing Pattern dialog:
Template

Input

Prototype Bracing Pattern

KBraceDown

Bracing Title

KBraceDown_Training3

3. To add nodes to the bracing, input the following into the Define Bracing Pattern dialog:

STAAD(X) Tower

47

Tutorials

Self-Supporting Tower per IS:802 / 806


Adding Bracing
Add

Input

Intermediate

(checked)

Intermediate Ratio

1/3

Click Add Node, then click Node 1 and Node 4 via the graphic.
A node appears on the member between Node 1 and Node 4, 1/3 of the way from the first node you
selected.
4. Add nodes to the graphic as shown by first clicking Add Node then selecting the two nodes between which
you want the new node to appear.

Note: Node numbers may vary depending on the order in which the nodes were created.
5. In the Member section of the Define Bracing Pattern dialog, select Redundant Horizontal, click Add
Member, then select the two nodes between which you want a new member to appear. Add sub-horizontal
members as shown by first clicking Add Member then selecting the two nodes between which you want
the new node to appear.

STAAD(X) Tower

48

Tutorials

Self-Supporting Tower per IS:802 / 806


Adding Bracing

6. In the Member section of the Define Bracing Pattern dialog, select Redundant Diagonal, click Add
Member, then select the two nodes between which you want the new member to appear. Add diagonal
members as shown.

7. Click Update.
The Define Bracing Pattern dialog closes and the custom bracing pattern is saved.
8. In the Model ribbon tab click the Save tool.
Your work so far has been saved. You may be prompted to save the file in a destination of your choice.

STAAD(X) Tower

49

Tutorials

Self-Supporting Tower per IS:802 / 806


Adding Components

Adding Components
Using the IS:802/806 code.
1. In the Components ribbon tab click the T-Frame tool.
A new Mount 1 appears in the Tower Model Explorer pane, the T-frame mount appears on the model in
the View pane, and its properties appear in the Properties pane.
2. In the Properties pane change the Elevation to 44 m.
3. In the Components ribbon tab click the Pipe/Dish Mount tool.
A new Mount 2 appears in the Tower Model Explorer pane, the pipe/dish mount appears on the model in
the View pane, and its properties appear in the Properties pane.
4. In the Properties pane change the Elevation to 40 m.
5. In the Components ribbon tab click the Low Profile Platform tool.
A new Mount 3 appears in the Tower Model Explorer pane, the platform appears on the model in the View
pane, and its properties appear in the Properties pane.
6. In the Properties pane change the Elevation to 35 m.
7. In the Tower Model Explorer pane expand Mount 3 then click on Low Profile Platform 33.5m.
The platform's properties appear in the Properties pane.
8. Input the following into the Properties pane:
Low Profile Platform Properties

Input

Width of Platform

4 m

No. of Mount Pipe: Face A

No. of Mount Pipe: Face B

No. of Mount Pipe: Face C

No. of Mount Pipe: Face D

9. In the Components ribbon tab click the Ladder tool.


A new Ladder 1 appears in the Tower Model Explorer pane, the ladder appears on the model in the View
pane, and its properties appear in the Properties pane.
10. Input the following into the Properties pane:
Ladder Properties

Input

Start Height

3 m

End Height

45 m

Face Id

Position

Outside

Face Offset

304.8 mm

Lateral Shift %[+/-0.5]

Note: End Height must be entered before Start Height.


11. In the Components ribbon tab click the Feedlines tool.
STAAD(X) Tower

50

Tutorials

Self-Supporting Tower per IS:802 / 806


Adding Loads and Load Groups
A new Feedline 1 appears in the Tower Model Explorer pane, the feedline appears on the model in the
View pane, and its properties appear in the Properties pane.
12. Input the following into the Properites pane:
Feedline Properties

Input

Start Height

0 m

End Height

44 m

Along

Face

Position

Inside

Leg/Face ID:

Face Offset

203 mm

Lateral Shift %[+/-0.5]

No. of Lines (Coaxes)

No. of Rows

Line Spacing

50 mm

Row Spacing

0 mm

13. To edit or add supports, go to the Tower Model Explorer Pane and expand Physical Model and right click
on the Supports folder. You can add the type of support desired by selecting it from the pop-up menu.
The restraint options for the support selected appear in the Properties pane and can be edited.
Note: For this model, a fixed support was assigned in the Setup Wizard and can be seen if the
Supports folder is expanded.
14. In the Model ribbon tab click the Save tool.
Your work so far has been saved. You may be prompted to save the file in a destination of your choice.

Adding Loads and Load Groups


Using the IS:802/806 code.
1. In the Tower Model Explorer pane expand Physical Model > Loads , then right click on the Load
Generation Parameters folder and select Add Wind/Ice Parameters from the pop-up menu then IS:875
Definition from its pop-up menu.
A new Wind/Ice Load Def.(IS:875):1 appears in the Tower Model Explorer pane and its properties
appear in the Properties pane.
2. In the Properties pane select Almora as the City/Town.
Note: Wind speed and gust factor have been automatically updated to reflect the inputted
location.
Terrain, Height, Structure Size Factor [k2]

Input

Terrain Category

Category 2

Structure Classification

STAAD(X) Tower

51

Tutorials

Self-Supporting Tower per IS:802 / 806


Primary Load Cases and Analysis

3.

4.

5.
6.
7.

8.

Expand the Load Cases drop-down menu and check the boxes next to all of the load cases.
The nine new load cases have been added as Load Groups 2 through 10 in the Tower Model Explorer
pane.
Expand each of the new Load Groups, then right click on each of their wind/ice loads and select Assign
from their pop-up menus, respectively.
The white boxes next to the wind/ice loads will turn green once they have been assigned. The new loads
have been assigned to the entire structure.
In the Tower Model Explorer pane expand Physical Model > Loads > Load Groups , then right click the
Load Group 1 folder and select Joint Load from the pop-up menu then Add Joint Load from its pop-up
menu.
A new Joint Load appears in the Tower Model Explorer pane and its properties appear in the Properties
pane.
In the Properties pane enter -1 kip for Fy.
In the Model ribbon tab click the Select Nodes icon and then select the top four nodes on the model in the
View pane.
In the Tower Model Explorer pane expand Physical Model > Loads > Load Group 1 then right click
Joint Load and select Assign from its pop-up menu.
The load group has been assigned to the nodes you selected.
In the Model ribbon tab click the Save tool.
Your work so far has been saved. You may be prompted to save the file in a destination of your choice.

Primary Load Cases and Analysis


Using the IS:802/806 code.
1. In the Tower Model Explorer pane expand Analysis > Whole Model > Load Cases , then right click the
Primary folder and select Add Primary Load Case from the pop-up menu.
A new Primary LoadCase 1 appears in the Tower Model Explorer pane and the load case editor appears
in the Properties pane.
2. In the Properties pane click the drop-down menu next to Load Group Type and check Select All.
The load groups appear in the Properties pane.
3. Click 1:Load Group 1, input 1.2 as the Factor, then click Add.
The load group with its assigned factor appears in the Properties pane under Selected Load Groups.
4. Click 2:Load Group 2, input 1.6 as the Factor, then click Add.
The load group with its assigned factor appears in the Properties pane under Selected Load Groups.
5. Repeat steps 3 through 6 to create the following primary load cases:
Primary LoadCase Number

Load Groups and Factors

1:Load Group 1 (1.2) + 3:Load Group 3 (1.6)

1:Load Group 1 (1.2) + 4:Load Group 4 (1.6)

10

1:Load Group 1 (0.9) + 7:Load Group 7 (1.6)

The three new load cases have been added as Primary LoadCases 8 through 10 in the Tower Model
Explorer pane.
6. In the Model ribbon tab click the Run Analysis tool.
The analysis results for a 1st order analysis method appear in the Output pane.
Note: You may be asked to save file in a destination of your choice prior to analysis.
Note: At least one primary load case must be defined in order to perform an analysis.
STAAD(X) Tower

52

Tutorials

Self-Supporting Tower per IS:802 / 806


Reviewing Results and Creating Reports
7. In the Tower Model Explorer pane expand Analysis then click the Whole Model folder.
The analysis options for the whole model appear in the Properties pane.
8. In the Properties pane select P-Delta Analysis as the Method then select Default as the Analysis Options.
9. In the Model ribbon tab click the Run Analysis tool.
The analysis results for the new method appear in the Output pane.
10. In the Model ribbon tab click the Check Code tool.
The code check operations appear in the Output pane.

Reviewing Results and Creating Reports


Using the IS:802/806 code.
1. In the Model ribbon tab select IS 802,806 as the Active Design Code.
2. In the Model ribbon tab click the Check Slenderness tool.
Any members which do not meet slenderness criteria per the selected code appear in the Output pane.
3.

4.
5.
6.

Tip: Selecting an entry in the Output pane will highlight the correlating member in the View pane.
In the Results ribbon tab click the Show All Results tool.
The design results appear in the Output pane. Members that have failed the design check are highlighted in
the View pane.
In the Results ribbon tab click the Show Selective Result tool then select any physical member.
Design results for the selected physical member appear in the Output pane.
Click the Report ribbon tab.
The Report Document Map and Selected Item List panes replace the previous panes.
In the Report Document Map pane expand Reports > Input Data , then click and drag the Section
Information item into the Selected Item List pane, as well as the Member Specification item.
Tip: While hovering in the Selected Item List pane, a red line appears to indicate where the item
will be placed.
Tip: Items in the Selected Item List pane can be rearranged by clicking and dragging them into a
new position.

7.

Click on the Generate Report icon


in the Selected Item List pane.
A report including data from your item appears in the View pane.

STAAD(X) Tower

53

Tutorials

Self-Supporting Tower per IS:802 / 806


Reviewing Results and Creating Reports

STAAD(X) Tower

54

Tutorials

You might also like