ADCP-80-329

Issue 2, September 1998

84-Circuit DSX-1 Front and Rear


Cross-Connect Panels
User Manual
Content

Page

INTRODUCTION ........................................................................... 1
Revision History ....................................................................... 1
Trademark Information .................................................................. 1
Related Publications ................................................................... 2
Admonishments ....................................................................... 2
1. GENERAL ............................................................................ 2
2. DESCRIPTION......................................................................... 3
A.

Functional Description ............................................................... 3

B.

Physical Description ................................................................ 7

C.

Technical Description ............................................................... 8

3. INSTALLATION ........................................................................ 8
A.

Panel Mounting ................................................................... 10

B.

Power and Ground Connections ...................................................... 10

C.

Input and Output Connections ........................................................ 11

D.

Cross-Connections ................................................................ 11

E.

Cross-Connection Verification ........................................................ 12

4. OPERATION ......................................................................... 12
5. MAINTENANCE....................................................................... 12
A.

Preventative Maintenance ........................................................... 13

B.

Corrective Maintenance ............................................................. 13

6. SYSTEM INTEGRATION SERVICES ....................................................... 14


7. CUSTOMER SUPPORT SERVICES ........................................................ 14

INTRODUCTION
This user manual describes the ADC 84-Circuit DSX-1 Panels and their use in DSX-1
applications. Throughout this manual, these will be referred to as panels.
Revision History
ISSUE

DATE

REASON FOR CHANGE

Issue 1

11/92

Original.

Issue 2

09/98

Update to current format standards, update corporate address.

Trademark Information
ADC and ADC Telecommunications are registered trademarks of ADC Telecommunications, Inc.

4-24883-0800

Page 1
1998, ADC Telecommunications, Inc.

ADCP-80-329
Issue 2, September 1998

Related Publications
Listed below are related manuals, their content, and their publication numbers. Copies of these
publications can be ordered by contacting the ADC Technical Assistance Center at 1-800-366-3891
(in U.S.A. or Canada) or 612-946-3000, extension 3475 (outside U.S.A. and Canada).
Title/Description

ADCP Number

Digital Signal Cross-Connect System Application Guide

80-303

DSX-1 Operational Procedures

80-322

Admonishments
Important safety admonishments are used throughout this manual to warn of possible hazards to
persons or equipment. An admonishment identifies a possible hazard and then explains what may
happen if the hazard is not avoided. The admonishments in the form of Dangers, Warnings,
and Cautions must be followed at all times. These warnings are flagged by use of the
triangular alert icon (seen below), and are listed in descending order of severity of injury or
damage and likelihood of occurrence.
Danger: Danger is used to indicate the presence of a hazard that will cause severe
personal injury, death, or substantial property damage if the hazard is not avoided.
Warning: Warning is used to indicate the presence of a hazard that can cause severe
personal injury, death, or substantial property damage if the hazard is not avoided.
Caution: Caution is used to indicate the presence of a hazard that will or can cause
minor personal injury or property damage if the hazard is not avoided.

1. GENERAL
This user manual describes features and functions of the 84-Circuit DSX-1 Panels. The
1.01
manual contains a description of the panels and installation instructions.
The 84-Circuit DSX-1 Panels are designed to provide high density terminations with
1.02
efficient cable management. Various panel designs provide applications for Central Office, CEV,
Hut and Outside Plant cabinets.
The 84-Circuit DSX-1 Panel can terminate three 28-circuit M1/3 multiplexers on a
1.03
single panel. Eighty-four associated DS-1 network elements (digital switch, channel banks, etc.)
can be terminated on another panel and then cross-connects tie the two DS-1 circuits together.
The 84-Circuit DSX-1 Panel operating procedures are the same as other DSX-1
1.04
equipment and are covered in ADCs DSX-1 Operational Procedures - ADCP-80-322.

Page 2
1998, ADC Telecommunications, Inc.

ADCP-80-329
Issue 2, September 1998

2. DESCRIPTION
This section contains a functional, physical and technical description of the 84-Circuit
2.01
DSX-1 Panel.
A. Functional Description
DSX-1 equipment provides a centralized, equal level cross-connect point for digital
2.02
signals. The 84-Circuit DSX-1 Panel is a high density cross-connect termination panel. It
provides jack access for monitoring, testing and circuit patching. A typical DSX-1 circuit
diagram is shown in Figure 1. Circuit cross-connects are identified by flashing LEDs. Flexible
configurations are available for front or rear cross-connect arrangements. The Input/Output
terminations are available with wire-wrap pins or 64 pin Amp connectors. Two circuit labeling
schemes, 1-84 or 1-28 A, B, C are available.
-48V

-48V

SHIELD GROUND
GROUND

SHIELD GROUND
GROUND

MON

OUT

IN

MON

OUT

IN

OUT
OUT
T
R
T
R

DIGITAL
EQUIPMENT

IN

OUT

TL

TL

OUT

TN
RN

TN
RN

TN
RN

TN
RN

T
R
T
R

IN

DIGITAL
EQUIPMENT

IN

IN

1409-A

Figure 1. Typical DSX-1 Cross-Connect

2.03

The variety of panel options available include:

Front Cross-Connect
x

Front Cross-Connect Panels provide jack access and cross-connect terminations on the
front of the panel. Both patching and cross-connects are made on the front of the panel.

Front Split Cross-Connect Panels have the cross-connect field split evenly on the left and
right side of the panel. See Figure 2. The cross-connect jumpers are distributed evenly to
both the left and right wire way, providing efficient cable management when full bays of
84-Circuit DSX-1 Panels are used in a central office.

Page 3
1998, ADC Telecommunications, Inc.

ADCP-80-329
Issue 2, September 1998

JACKFIELD
CROSS-CONNECT FIELD

TL

OUT TN
RN
IN

14

T
L

14

TN
RN

FRONT
1

14

14

TL
OUT T
R
IN T
R

A
1

14

T
L

T
L

14

14

15

28
TL
T OUT
R
T
IN
R

A
15

28

TL
OUT T
R
IN T
R

15

28

B
1

28

15

T
L

T
L

14

TL
OUT T
R
IN T
R

15

TL
T OUT
R
T
R IN

28

B
15

28
TL
T OUT
R
T
R IN

JACKFIELD
SPLIT CROSS-CONNECT FIELDS
CROSS-CONNECT
CABLE RINGS
REAR
1

10

11

GROUP A CIRCUITS
15
20 21

25

28

T
OUT R
IN

-48V GND

1
T
R OUT

T
R

T
R

SG CG

10

11

10

IN

GROUP B CIRCUITS
15
20

21

25

IN

28
T OUT
R

T
R

T
R

GROUP C CIRCUITS
15
20 21

25

IN

28

T
OUT R

T
R OUT

T
R

IN

11

T
OUT R

T
R

IN

1410-A

Figure 2. Front Split Cross-Connect Panel (Wire-Wrap Configuration Shown)

Left Side Cross-Connect Panels have the cross-connect field on the left side of the panel.
See Figure 3. This panel is designed for outside plant or hut applications where the
ultimate requirement will not exceed eight 84-Circuit DSX-1 Panels. The Left Side
Cross-connect Panel is not recommended when a full seven foot bay of DSX is required.
Jumper build-up would cause congestion in the wire way.

14

15

IN

T
R

T
R

A
1

IN

15

IN

28

14

T
L

T
L

14

TL

T
R

T
R

OUT
IN

B
1

IN

OUT

A
14

14

15

28
TL

TL

OUT

14

TL

T
R

TL

OUT

28

TL

OUT

T
R

T
R

15

28

15

15
T
L

OUT
IN

28

T
L

28

CROSS-CONNECT FIELD

JACKFIELD

Figure 3. Front Left Cross-Connect Panel

Page 4
1998, ADC Telecommunications, Inc.

1411-A

ADCP-80-329
Issue 2, September 1998

CEV/Total Front Access Panels have all the Input/Output terminations, cross-connect
terminations, jacks and power lugs on the front. See Figure 4. This panel is used in
applications where rear access is prohibited, such as; CEVs or Huts where bays are
placed against the wall; Central offices where bays are placed back to back or against an
obstruction; OSP cabinets with front access only.

Combo Panels combine 84 DSX-1 terminations and three DS3 interconnect circuits on a
single panel. See Figure 5. This panel is typically used in Outside Plant cabinets where a
combo panel will terminate the incoming electrical side of a 150 MB Fiber Optic
Terminal or OC3 Sonet Terminal. This panel uses Minimum Point of Presence (MPOP)
interconnect which eliminates the need for a separate DSX-3 interface.

14

A
1

14

TL
OUTT
R
IN T
R

15
14

TL
OUTT
R
IN T
R
C

-48

GND

SPLIT CROSSCONNECT FIELD

14

15

28

14

T
L
M

T
L
M

28

B
1

14

TL
OUTT
R
IN T
R

15

28

INPUT/OUTPUT FIELD

15

28
TL
T OUT
R
T IN
R
A

15
T
L
M

14

15

15

T
L
M

14

28
TL
T OUT
R
T IN
R

28
B
15

28
TL
T OUT
R
T IN
R
C

28

14

15

28

SG

CG

SPLIT CROSSCONNECT FIELD

JACKFIELD

1412-A

Figure 4. Total Front Access Cross-Connect Panel

Page 5
1998, ADC Telecommunications, Inc.

ADCP-80-329
Issue 2, September 1998

DS3 SECTION
IN

OUT

MON

IN

A
B

14

15

TL
OUT T
R
IN T
R

OUT

MON

28

14

15

15

14

15

28

TL

TL
T OUT
R
T
R IN

OUT T
R
IN T
R

14

IN

OUT

MON

MON

T
L

T
L

14

28

MON

I
TL
T OUT
R
T
R IN

OUT

B
OUT

28

IN

IN
14

TL
T OUT
R
T
R IN

TL
OUT T
R
IN T
R

MON

B
IN

OUT

15

28

15

T
L

T
L

28

DSX-1 JACKFIELD

DSX-1 CROSS-CONNECT FIELD

BREAKDOWN OF DS3 SECTION OF PANEL


MPOP
FRONT VIEW
IN

OUT

REAR VIEW

MON

OUT
BNC
CONNECTORS

ACCESS
JACKS

A
IN

OUT

IN

MON

OUT
MUX

IN
IN

FOT
OUT

DS3 SCHEMATIC SIDE "A" OF CIRCUIT


A MON

USING ONE MPOP FOR ONE DS3


A - IN

R3

A - OUT

IN

OUT
A

BNC
OUT

R2

L1

OUT A

MUX

FOT
OUT

R1

IN
A BNC
IN
B - OUT

IN A
L1

B - IN

BLOCK DIAGRAM

DS1 (28)
150 MB
FOT

DS3 (3)

DS3
MPOP

DS3 (3)

M1/3
MUX

DS1 (28)

84 CIRCUIT
DSX-1 PANEL

DS1 (28)

1413-A

Figure 5. DSX-1/3 Combo Panel

Page 6
1998, ADC Telecommunications, Inc.

ADCP-80-329
Issue 2, September 1998

Rear Cross-Connect
x

Rear Cross-Connect Panels have the IN/OUT and cross-connect terminations on the rear
of the panel with jack access on the front. See Figure 6. This panel is typically used in
central offices with existing rear cross-connect panels.
1

14

14
T
L

15

28

NOTE: CROSS-CONNECT AND


INPUT/OUTPUT FIELDS
ARE ON THE REAR OF
THE PANEL

T
L

14

15

28

15

T
L

T
L

28

1414-A

JACKFIELD

Figure 6. Rear Cross-Connect Panel

B. Physical Description
Separate 84-Circuit DSX-1 Panels are designed for mounting in 19 or 23 inch (48.3 or
2.04
58.4 cm) equipment racks and can be recessed 2, 3 or 4 inches (5.1, 7.6 or 10.2 cm). Panels are
available in putty white or black color. The chassis dimensions vary, as shown in Table 1.
The Jackfield, located on the front of the panel consist of space saving Bantam jacks and
2.05
LED tracer lamps. The Input/Output terminations are located on the rear except for Total Front
Access Panels. The terminations are wire-wrap pins and on some models can be 64 pin Amp
connectors. The Cross-connect section consists of wire- wrap termination blocks for connecting
DSX-1 circuits. The cross-connect section is on the front or the rear of the panel depending upon
the panel model. See Figure 7 for a schematic representation of a DSX-1 circuit diagram.
JACKFIELD

-48V

SHIELD GROUND
GROUND

MON

OUT

IN

TL
T
R

T
R OUT
T
IN
R

OUT

IN

T
R

CROSS-CONNECT
FIELD
DSX-1 CIRCUIT
DIAGRAM

INPUT / OUTPUT
FIELD
1323-A

Figure 7. DSX-1 Circuit Schematic

Page 7
1998, ADC Telecommunications, Inc.

ADCP-80-329
Issue 2, September 1998

C. Technical Description
2.06

Table 1 lists the specifications for each available 84-Circuit DSX-1 Panel.
Table 1. 84-Circuit DSX-1 Panel Specifications

PARAMETER

SPECIFICATION

REMARKS

5.0 u 23.0 u 8.0 inches


(12.7 u 58.4 u 20.3 cm)

Front Split and Front Left CrossConnect

7.0 u 23.0 u 8.0 inches


(17.8 u 58.4 u 20.3 cm)

Total Front Access CrossConnect

5.0 u 23.0 u 10.0 inches


(12.7 u 58.4 u 25.4 cm)

Rear Cross-Connect

5.0 u 19.0 u 10.0 inches


(12.7 u 48.3 u 25.4 cm)

Rear Cross-Connect

7.0 u 19.0 u 8.0 inches


(17.8 u 48.3 u 20.3 cm)

Front Cross-Connect

Panel Requirement

48 Vdc

0.75 Amp fuse max.

LEDs

.008 Amp/LED

Contact Rating

100 mA at r 130 Vdc

Maximum

(Bantam Jacks)

40 dBm

Maximum

Physical

Dimensions (H u W u D)

Electrical

Environmental

Operating Temperature

40q F to +149q F
(40q C to +65q C)

Non-Operating Temperature

85q F to +185q F
(55q C to +85v C)

Humidity

0% to 95%

Non-Condensing
Operating/Non-Operating

3. INSTALLATION
Danger: To prevent electrical shock, never install telephone equipment in a wet location
or during a lightning storm. When installing or modifying telephone lines, disconnect
lines at the network interface before working with uninsulated lines or terminals.
Installation of 84-Circuit DSX-1 panels involves mounting of the panels in the various
3.01
bays and wiring them to the equipment. Each panel is shipped with an installation drawing. The
drawing defines the specific termination connections required to complete the wiring.
For full bay applications 5.0 inch (12.7 cm) spacers and upper and lower cable troughs
3.02
are recommended for proper cable management. Panels are installed from the bottom of the bay
up. Except for Total Front Access panels, the Out equipment cables run down the right side
(rear) of the bay. The In equipment cables run down the left side (rear) of the bay. See Figure 8.

Page 8
1998, ADC Telecommunications, Inc.

ADCP-80-329
Issue 2, September 1998

The maximum of Total Front Access panels installed in a bay is eight. The Out
3.03
equipment cables run down the right side (front) of the bay. The In equipment cables run down
the left side (Front) of the bay. Refer to Figure 8.

OUT EQUIPMENT
CABLES

IN EQUIPMENT
CABLES

CABLE TROUGH
FRONT OF BAY

IN EQUIPMENT
CABLES

OUT EQUIPMENT
CABLES

TOTAL FRONT ACCESS


84 CIRCUIT DSX-1 PANEL

84 CIRCUIT DSX-1 PANEL

CABLE TROUGH
FRONT OF BAY

TYPICAL BAY (REAR)

TOTAL FRONT ACCESS PANEL BAY


(FRONT)
1416-A

Figure 8. IN/OUT Equipment Cabling

Page 9
1998, ADC Telecommunications, Inc.

ADCP-80-329
Issue 2, September 1998

A. Panel Mounting
Mounting brackets, cable rings and labels are packaged separately and installed on site.
3.04
The front cross-connect cable rings are installed at the same time as the panel is secured in place.
Rear cross-connect rings and the labels are installed after the panel is secured in place.
3.05

Install the panels using the following procedures:

1.

Attach the mounting brackets onto each panel. Use special thread-forming screws
(provided) to achieve proper grounding. Tightened to a minimum of 8 inch/lb..

2.

Install the panels in the assigned bay locations using #12-24 mounting screws provided.
For Front Cross-Connect panels place the cable rings on top of the panel mounting
bracket, then insert the mounting screws.

3.

Install cable rings at the rear of the panel (for rear cross-connect models) using special
thread-forming screws as in step (1).

4.

Attach the designation labels.

B. Power and Ground Connections


Danger: All DSX wiring should be connected with the system office battery input off or
disconnected at the office Battery Distribution Fuse Bay (BDFB) to prevent electrical
shock.
Installation of DSX panels involves the interconnection of circuits on terminal blocks on
3.06
the panels, and connection of power and ground for the LED indicators.
Warning: Fusing at greater than 0.75 Amps per panel may cause panel damage.
Office power to each panel should be fused at 0.75 Amp. Use a minimum of 22 AWG
3.07
wire when making power connections. Typical 84-Circuit DSX-1 panel power strips are shown
in Figure 9. Connect power wires from each panel to the fuse panel as follows:
1.

Connect the 48V terminal on the panel to a NEG () terminal on the fuse panel (white
wire).

2.

Connect the GND terminal on the panel to the corresponding POS (+) terminal on the
fuse panel (black wire).

3.

Connect the CG terminal on the panel to the office frame ground (green wire). This is the
recommended chassis grounding procedure.
Note: The metal strap between the CG (Chassis Ground ) and SG (Shield Ground)
terminals on the module may be removed to isolate the shield ground from the chassis
ground.

Page 10
1998, ADC Telecommunications, Inc.

ADCP-80-329
Issue 2, September 1998

TO FUSE PANEL NEG (-) TERM


WHITE WIRE

TO FUSE PANEL POS (+) TERM

METAL
STRAP

TO OFFICE FRAME GROUND

BLACK WIRE
-48

GREEN WIRE

GND

-48V

GND

SG

CG
1417-A

Figure 9. Power Terminal Strips

C. Input and Output Connections


The recommended cable for connecting digital equipment to DSX-1 panels is 22-26
3.08
AWG shielded twisted pair cable (AT&T 600C or 1249 equivalent) grounded at one end only.
Maximum cable length for 600C is 655 feet (200.0 m) and 450 feet (137.0 m) for 1249.
Refer to schematics and connection table found on the installation drawing for selection
3.09
of IN and OUT terminations on the DSX-1 Input/Output section of the panel.
Depending on panel configuration the Input/Output connections are; wire-wrap pins, 64
3.10
pin connectorized cables or both. Connect office equipment inputs and outputs to the selected
DSX-1 Input/Output section. Record each equipment connection on the corresponding
designation strips located at the sides of the Input/Output section.
D. Cross-Connections
The DSX-1 cross-connect wires add to the overall digital signal losses depending on the
3.11
wire length. To assure reliable signal levels, the recommended maximum cross-connect length
including cross aisle cable (when applicable) is 85 feet (26.0 m).
Select the designated digital equipment to be cross-connected by referring to the office
3.12
equipment connection records on the DSX-1 designation strips and cards.
DSX-1 cross-connections are made to wire-wrap terminals, as shown in Figure 10, on
3.13
the Cross-connect section located at either the front or rear of the panel depending upon panel
configuration. Make the desired cross-connections as follows:
1.

Connect the IN T and R of the originating DSX-1 position to the OUT T and R of the
terminating DSX-1 position as selected in paragraph 3.12.

2.

Connect the OUT T and R of the originating DSX-1 position to the IN T and R of the
terminating DSX-1 position .

3.

Interconnect the tracer lead (TL) terminals of the originating and terminating DSX-1
units.

Page 11
1998, ADC Telecommunications, Inc.

ADCP-80-329
Issue 2, September 1998

5 CONDUCTOR
JUMPER WIRE

TWISTED PAIRS

TL
TN
OUT

RN
TL

TN
IN

CROSS-CONNECT
TERMINAL BLOCKS

RN

TN
RN

OUT

TN
RN

IN

1418-A

Figure 10. DSX-1 Cross-Connects

E. Cross-Connection Verification
3.14

Equipment assignment (cross-connects) are verified using the following procedures:

1.

Insert a patch plug into the monitor jack of a equipment termination.

2.

Observe the tracer lamps. The tracer lamp above the monitor jack with the plug inserted
and the tracer lamp above the monitor jack of the cross-connected equipment will flash
for about 30 seconds and then remain lit.

3.15

The above procedure may be used, on an in-service basis, without service interruption.

4. OPERATION
The operating procedures for the 84-Circuit DSX-1 Panel are the same as all DSX-1
4.01
equipment. For step by step operating procedures, refer to DSX-1 Operational Procedures
ADCP-80-322.

5. MAINTENANCE
The 84-Circuit DSX-1 Panel maintenance requirements are minimal, consisting of
5.01
periodic cleaning and tracer lamp replacement.

Page 12
1998, ADC Telecommunications, Inc.

ADCP-80-329
Issue 2, September 1998

A. Preventative Maintenance
Panels should be cleaned during routine office equipment maintenance. Accumulated
5.02
dirt and film should be removed using a vacuum cleaner and clean soft brushes and cloths. Care
must be taken to prevent dust and dirt from getting into panel jacks.
B. Corrective Maintenance
Danger: All corrective maintenance should be performed with the 48 Vdc office
battery off or disconnected from the panel to avoid electrical shock.
5.03

Corrective maintenance consists of:

1.

Replacement of burned out tracer lamps.

2.

Inspection and repair of jacks and wiring.

3.

Inspection and repair of wire-wrap connections.

Tracer Lamp Replacement


Burned out tracer lamps are replaced at the front of the jack field. Lamps are removed by
5.04
pulling them from the sockets. No special tools are required. Replacement lamps must be
replaced with negative () terminal up.
Jack/Wiring Inspection and Repair
Trouble shooting of DSX-1 jacks and wiring consists of visual inspection and continuity
5.05
testing. Cross-connections can be quickly checked by inserting a dummy plug or patch cord into
the monitor jack of appropriate circuit and observe the lit LEDs.

Page 13
1998, ADC Telecommunications, Inc.

ADCP-80-329
Issue 2, September 1998

6. SYSTEM INTEGRATION SERVICES


ADC offers the following system integration services. For calls originating in the U.S.A.
6.01
or Canada, dial 1-800-366-3891, extension 3000. For calls originating outside the U.S.A. or
Canada, dial 612-946-3000.
Technical Assistance Center

Product Management
Project Engineering
Project Administration
Network Design
Broadband Design (RF Design and Strand Mapping)
Integration Network Testing
Network Monitoring (Upstream or Downstream)
Power Monitoring
Remote Surveillance
System Turn-Up and Test
Service/Maintenance Agreements

Technical Training

Product Technology
Custom Designed Training

Technical Operations

Detail Engineering
End-to-End Installation
Drafting Services

7. CUSTOMER SUPPORT SERVICES


ADC offers the following customer support services. For calls originating in the U.S.A.
7.01
or Canada, dial 1-800-366-3891, then request the extension listed. For calls originating outside
the U.S.A., Canada, or Europe, dial 612-946-3475 or 612-946-3000 (1 is the U.S. country
code). For calls originating in Europe, contact the ADC Brussels office (32-2-712-6542 for
technical assistance; 32-2-712-6500 for sales administration).
BCG Technical Assistance Center
BCG Technical Assistance Center
Extension 3475
E-Mail: bcgtac@adc.com

Technical Information
Technical Information
System/Network Configuration
Product Specification
Product Application
Training
Installation and Operation Assistance
Troubleshooting and Repair
Field Assistance

Sales Administration
Extension 3000

Quotation Proposals
Ordering
Delivery
General Product Information

Product Return Department


Extension 3000
E-Mail: repair&return@adc.com

ADC Return Authorization number and instructions


must be obtained before returning products.

Product information and service can also be obtained by accessing the ADC web site at
7.02
www.adc.com or by writing ADC Telecommunications, Inc., P.O. Box 1101, Minneapolis,
Minnesota 55440-1101, U.S.A.

Page 14
1998, ADC Telecommunications, Inc.

ADCP-80-329
Issue 2, September 1998

Contents herein are current as of the date of publication. ADC reserves the right to change the contents without prior
notice. In no event shall ADC be liable for any damages resulting from loss of data, loss of use, or loss of profits
and ADC further disclaims any and all liability for indirect, incidental, special, consequential or other similar
damages. This disclaimer of liability applies to all products, publications and services during and after the
warranty period.
This publication may be verified at any time by contacting ADCs Technical Assistance Center at 1-800-366-3891,
extension 3223 (in U.S.A. or Canada) or 612-946-3223 (outside U.S.A. and Canada), or by writing to ADC Telecommunications,
Inc., Attn: Technical Assistance Center, Mail Station #77, P.O. Box 1101, Minneapolis, MN 55440-1101, U.S.A.

1998, ADC Telecommunications, Inc.


All Rights Reserved
Printed in U.S.A.

Page 15