Monolithic Insulation Joints are manufactured from 1 to 48 for different ratings as per
ANSI standards.
Monolithic Insulation Joints are designed for temperatures ranging from -20C to 170C.
Monolithic Insulation Joints are designed as per ANSI 16.25 and are tested at 1.5 times the
design pressure.
Standard Features:
Seals
Insulating Ring
Coating
Service
Location
Metallic Parts
Forged Rings
Pup Pieces
Material used :
Special Features :
Non Standard Wall Thickness can be
manufactured as per the customers
requirements.
Pneumatic Test
NDT examination
(RT,UT,MPT,DPT)
Electrical Test :
Insulation Resistance Test @ 1000 Volt DC
Dielectric strength test range is 5KV to 15KV
at a Volt of 50HZAC and for a duration of 1
min.
Holiday Test
Adhesion Test
Quality Assurance :
Manufacturer IGP have been accredited by DNV Quality assurance programs since 1996 and
comply with ISO 9001-2008.
All insulation joints will be tested before despatch from their factory. Proper identification and
installation procedures will be furnished.
Chemical and Mechanical test certificates for all material elements used will be provided as per
standards
Standards :
For die-electric non ferrous material ASTM
For resinous materials, paint, and shot blasting : ASTM, ISO, BS.
For weld and related materials AWS, ASME IX, ASME II PART C, BS4515.
NDE Examinations and Inspections : ASME V, ANSI B31.3, ANSI B31.4, ANSI B31.8 ,ASME VIII,
API 1104
Testing and Inspection agencies:
PDO, BVIS, LRIS, DNV, EIL, CEIL,TUV(NOD &SUD), GLIS, SGS, VELOSI,ICS, Mecon, LRIS
Design calculation:
We will provide computerized calculations for verification of mechanical strengths of the joints
in compliance with ASME VIII DIV.1, APP.2 and applicable codes (ANSI B31.3, 31.4, 31.8) or
according to customer/end user specifications.