You are on page 1of 192

Alcatel-Lucent 1850

Transport Service Switch (TSS-320 and TSS-160) | Release 3.1


Installation Guide

Alcatel-Lucent Proprietary
This document contains proprietary information of
Alcatel-Lucent and is not to be disclosed or used
except in accordance with applicable agreements.

8DG09019HAAA
JUNE 2009
ISSUE 1

Alcatel, Lucent, Alcatel-Lucent and the Alcatel-Lucent logo are trademarks of Alcatel-Lucent. All other trademarks are the property of their
respective owners.
The information presented is subject to change without notice. Alcatel-Lucent assumes no responsibility for inaccuracies contained herein.
Copyright 2009 Alcatel-Lucent. All Rights Reserved.
Conformance statements
Interference Information: Part 15 of FCC Rules
This equipment has been tested and found to comply with the limits for Class A digital device, pursuant to Part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful interferences when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio frequency energy. If the equipment is not installed and used in
accordance with the guidelines in this document, the equipment may cause harmful interference to radio communications. Operation of this
equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at the
expense of the user.
Security statement
In rare instances, unauthorized individuals make connections to telecommunications networks through the use of remote access feature. In
such an event, applicable tariffs require that the customer pay all network charges for traffic. Alcatel-Lucent cannot be responsible for such
charges and will not make any allowances or give any credit for charges that result from unauthorized access.
Limited warranty
Alcatel-Lucent provides a limited warranty to this product. For terms and conditions of sale, contact your Alcatel-Lucent Account Team.

Alcatel-Lucent - Proprietary
See notice on first page.

Contents
About this document

vii

Purpose........................................................................................................................................................vii
Reason for revision.....................................................................................................................................vii
Intended audience .......................................................................................................................................vii
How to use this document ..........................................................................................................................vii
Safety information ......................................................................................................................................vii
Caution to avoid equipment damage............................................................................................................ x
Conventions used......................................................................................................................................... xi
Related information ....................................................................................................................................xii
Document support......................................................................................................................................xiii
Technical support ......................................................................................................................................xiii
How to order ..............................................................................................................................................xiii
How to comment .......................................................................................................................................xiii
Packaging collection and recovery requirements .....................................................................................xiii
Recycling/take-back/disposal of product ................................................................................................... xv
1

Mechanical installation of shelves into the Alcatel-Lucent TSS ETSI rack

1-1

Overview....................................................................................................................................................1-1
Mechanical installation of the Alcatel-Lucent 1850 TSS-320 subrack into the TSS rack ......................1-2
Mechanical installation of the Alcatel-Lucent 1850 TSS-160 sub-rack into the TSS rack...................1-15
2

Electrical installation rules

2-1

Overview....................................................................................................................................................2-1
Alcatel-Lucent 1850 TSS-320 boards installation and electrical connections ......................................2-10
Alcatel-Lucent 1850 TSS-320 connection points - common unit..........................................................2-11
Alcatel-Lucent 1850 TSS-320 connection points - SDH units ..............................................................2-12
Alcatel-Lucent 1850 TSS-320 connection points - DATA units ...........................................................2-15
Alcatel-Lucent 1850 TSS-320 connection points Optical Amplifier units.........................................2-18
Alcatel-Lucent 1850 TSS-320 connection points - DWDM unit...........................................................2-19
Alcatel-Lucent 1850 TSS-320 connection points CWDM units.........................................................2-21
Power supply & synchronization ............................................................................................................2-24
8DG09019HAAATQZZA
June 2009

Alcatel-Lucent Proprietary
See notice on first page.

iii

Power supply connection ........................................................................................................................2-25


GENTRU power connection ...................................................................................................................2-27
Synchronization connections ..................................................................................................................2-32
EC320 unit connection ............................................................................................................................2-38
MATRIX unit connection .......................................................................................................................2-39
Back panel electrical connections ...........................................................................................................2-46
Rack lamp connection .............................................................................................................................2-47
Remote alarm connection........................................................................................................................2-50
Housekeeping connection .......................................................................................................................2-52
Shelf ID connection.................................................................................................................................2-54
STEP-UP connections .............................................................................................................................2-56
Auxiliary channel connection .................................................................................................................2-60
Electrical cables routing ..........................................................................................................................2-62
Fiber routing ............................................................................................................................................2-63
Alcatel-Lucent 1850 TSS-160 boards installation and electrical connections ......................................2-64
Alcatel-Lucent 1850 TSS-160 connection points - common units ........................................................2-65
Alcatel-Lucent 1850TSS-160 connection points - SDH units ...............................................................2-67
Alcatel-Lucent 1850 TSS-160 connection points DATA units ..........................................................2-70
Alcatel-Lucent 1850 TSS-160 connection points Optical Amplifier units.........................................2-73
Alcatel-Lucent 1850 TSS-160 connection points DWDM units ........................................................2-74
Power supply & synchronization ............................................................................................................2-77
GENTRU Power supply connection .......................................................................................................2-78
GENTRU power connection ...................................................................................................................2-80
MANGTRU power supply connection ...................................................................................................2-84
Synchronization connections ..................................................................................................................2-90
EC320 unit connection ............................................................................................................................2-96
MATRIX unit connection .......................................................................................................................2-97
Electrical connections............................................................................................................................2-103
STEP-UP A/B cable ..............................................................................................................................2-106
Rack lamp cable ....................................................................................................................................2-107
Housekeeping cable pin-out ..................................................................................................................2-108
Electrical cable routing..........................................................................................................................2-109
Fiber routing ..........................................................................................................................................2-111
Fiber conveyor installation....................................................................................................................2-112
iv

Alcatel-Lucent - Proprietary
See notice on first page.

8DG09019HAAATQZZA
June 2009

Optical jumper routing ..........................................................................................................................2-113


3

Optical fiber

3-1

Overview....................................................................................................................................................3-1
Placing/removing devices into the sub-rack .............................................................................................3-2
4

Migration from Rel.1.x to Rel.3.x in Alcatel-Lucent 1850 TSS rack

4-1

Overview....................................................................................................................................................4-1
Safety rules ................................................................................................................................................4-2
Migration hardware procedure (greenfield)..............................................................................................4-3
Migration description ................................................................................................................................4-7
Migration hardware procedure (upgrade) ...............................................................................................4-11
20G packet processors to packet modules migration .............................................................................4-13
HO to HO+LO migration (MT320LO and LOAs) .................................................................................4-17
A

Suggested cables

A-1

Overview...................................................................................................................................................A-1
B

Installation kit

B-1

Overview................................................................................................................................................... B-1

8DG09019HAAATQZZA
June 2009

Alcatel-Lucent - Proprietary
See notice on first page.

About this document

Purpose

This manual provides instructions for installation and testing of the Alcatel-Lucent 1850
Transport Service Switch (TSS-320 and TSS-160). This manual is not a service manual.
Refer to 8DG09019KAAA Alcatel-Lucent 1850 Transport Service Switch (TSS-320
and TSS-160) User Provisioning Guide for any activities involving circuit turn-up, or
8DG09019CAAA Alcatel-Lucent 1850 Transport Service Switch (TSS-320 and TSS160) Maintenance and Trouble Clearing Guide for trouble analysis and regular
maintenance.
In addition of this manual, read also the local documentation, especially about the
electrical cables.
Reason for revision

This is the first issue of this document. It regards the Release 3.1 ETSI.
Intended audience

This manual is intended for individuals who are responsible for the installation,
acceptance, operations, and maintenance of the Alcatel-Lucent 1850 TSS-320 and TSS160,
How to use this document

This manual is divided into several chapters and appendices. The first chapter contains
safety information and general installation information. The other chapters provide
instructional steps for personnel needing additional detail or background information.
This document describes Alcatel-Lucent 1850 TSS-320 and TSS-160 operations. Refer to
the Table of Contents to locate specific information by chapter.
Safety information

For your safety, this document contains safety statements. Safety statements are given at
points where risks of damage to personnel, equipment, and operation may exist. Failure
to follow the directions in a safety statement may result in serious consequences.
8DG09019HAAATQZZA
June 2009

Alcatel-Lucent Proprietary
See notice on first page.

vii

Safety precautions

Adhere to the following safety precautions:


Electrostatic discharge (ESD)
You must be properly grounded when making contact with the Alcatel-Lucent 1850
Transport Service Switch (TSS-320 and TSS-160) frame and handling circuit packs, disk
drives, and tapes. Wrist strap ground cords should be routinely tested for the minimum 1megohm resistance. The code of the Wrist strap is AD 03406 0001.
Plug-in storage
Circuit packs should be stored in static-safe packaging or in a grounded cabinet.
For additional safety precautions, please see the Safety Guide.
General Rules

Check that the equipment is operating with all the shields properly positioned (dummy
covers, ESD connector protections, etc.).
Carefully observe the front-panel warning labels prior to working on optical connections
while the equipment is in-service.
To reduce the risk of damaging the electrostatic sensitive devices, it is mandatory to use
the elasticized band (worn around the wrist) and the coiled cord connected to the rack
ground when having to touch the equipment.
FIXING THE UNITS (AND MODULES) INTO THE SUBRACK
(caution to avoid equipment damage)
The screw tightening torque for fixing the units (and modules, if any and if screwfastened) into the subrack must be:
2.8 kg x cm (0.28 Newton x m) 10 %
Exceeding this value may result in screw breaking.
Rules for shielded cables

WARNING: The intra-building port(s) of the equipment or subassembly is suitable for


connection to intrabuilding or unexposed wiring or cabling only. The intra-building
port(s) of the equipment or subassembly MUST NOT be metallically connected to
interfaces that connect to the Outside plant or its wiring. These interfaces are designed
for use as intra-building interfaces only and require isolation from the exposed Outside
plant cabling.
The addition of Primary Protectors is not sufficient protection in order to connect these
interfaces metallically to Outside plant wiring.
Equipment heat release
viii

Alcatel-Lucent - Proprietary
See notice on first page.

8DG09019HAAATQZZA
June 2009

Due to high heat release of the TSS-320 and TSS-160 equipments, special room cooling
is required.

Electrostatic discharge

Electrostatic discharge (ESD), caused by touching with the hand for example, can destroy
semiconductor components. The correct operation of the complete system is then no
longer assured. Industry experience has shown that all semiconductor components can be
damaged by static electricity that builds up on work surfaces and personnel. The
electrostatic discharge can also affect the components indirectly via contacts or conductor
tracks.
The electrostatic charges are produced by various charging effects of movement and
contact with other objects. Dry air allows greater static charges to accumulate. Higher
potentials are measured in areas with low relative humidity, but potentials high enough to
cause damage can occur anywhere.

ESD instructions

Observe the following ESD instructions to avoid damage to electrostatic-sensitive


components:
Assume that all solid-state components and assemblies are sensitive to ESD.
Wear working garment made of conductive (ESD safe) not entirely cotton to avoid
electrostatic charging.
Touch the circuit packs at the edges or the insertion and removal facilities only.
Touch the SFP modules at the edges only.
Ensure that the rack is grounded.
Wear a properly grounded ESD wrist strap (connected to the rack bonding point, for
example).
Work in an ESD safe work area or workstation. An ESD safe work area should be
equipped with a grounded ESD wrist strap and a grounded ESD mat or ESD grounded
dissipative work surface. A grounded ESD mat or work surface must have a ground cord
with one end attached to the mat or surface and the other end connected to a ground point
(the rack ESP bonding point, for example). Do not work with ESD sensitive devices
unless the area is properly equipped.
Conductively connect all test equipment and trolleys to the rack ESP bonding point.
Store and ship circuit packs and components in their shipping packing. Circuit packs and
components must be packed and unpacked only at workplaces suitably protected against
build-up of charge.
Whenever possible, maintain the relative humidity of air above 20%.
ESD instructions are valid in the field during the installation steps.

8DG09019HAAATQZZA
June 2009

Alcatel-Lucent - Proprietary
See notice on first page.

ix

Caution to avoid equipment damage


Right operations for unit insertion

Open the levers before to plug the unit.


To mate the plastic body of the connectors. Pushing on the front panel, balancing the
strain without push on the levers.
Push on the levers in order to finish the connector mating.
Fix the unit to the subrack by means of screws, before to insert another unit.
Forbidden operations for unit insertion

Dont push just on one lever only.


Dont force the units.
Avoid impact during the units handling.

Alcatel-Lucent - Proprietary
See notice on first page.

8DG09019HAAATQZZA
June 2009

Right operations for unit extraction

Unscrew the top and bottom screws before extracting the unit.
Act on the levers opening gently as shown in the picture.
Pull the unit as shown in the picture.
Conventions used

This guide uses the following typographical conventions:


Appearance

Description

Italicized text

File and directory names

Emphasized information

Titles of publications

A value that the user supplies

Text that is displayed in a graphical user interface or in a


hardware label

The name of a key on the keyboard

graphical user interface text


or key name

input text

Command names and text that the user types or selects as


input to a system

output text

Text that a system displays or prints

8DG09019HAAATQZZA
June 2009

Alcatel-Lucent - Proprietary
See notice on first page.

xi

Related information

The following is a list of related documents:


8DG09019AAAA Alcatel-Lucent 1850 Transport Service Switch (TSS-320 and TSS160) Release 3.1 Product Information and planning Guide. Provides information on
Equipment description, composition, features of the equipment, detailed unit description,
characteristics, hardware settings, and documents common units used in the different
configurations of the product
8DG09019DAAA Alcatel-Lucent 1850 Transport Service Switch (TSS-320 and TSS160) Release 3.1 TL1 User Provisioning Guide. Provides information on provisioning
procedures by means of TL1
8DG09019BAAA Alcatel-Lucent 1850 Transport Service Switch (TSS-320 and TSS160) Release 3.1 TL1 Commands Guide. Provides comprehensive resource to all
Translator Language 1 commands
8DG09019CAAA Alcatel-Lucent 1850 Transport Service Switch (TSS-320 and TSS160) Release 3.1 Maintenance and Trouble-Clearing Guide. Provides information on
Maintenance and Troubleclearing procedures.
8DG09019FAAA Alcatel-Lucent 1850 Transport Service Switch (TSS-320 and TSS160) Release 3.1 Safety Guide. Provides information and safety guidelines to safeguard
against personal injury and to prevent material damage to the equipment.
8DG09019HAAA Alcatel-Lucent 1850 Transport Service Switch (TSS-320 and TSS160) Release 3.1 Installation Guide. Provides information on Equipment Installation.
(This document)
8DG09019GAAA Alcatel-Lucent 1850 Transport Service Switch (TSS-320 and TSS160) Release 3.1 Engineering Rules. Privides the design constraints for engineering a
WDM line system.
8DG09019EAAA Alcatel-Lucent 1850 Transport Service Switch (TSS-320 and TSS160) Release 3.1 Command Line Interface Guide. Provides a comprehensive resource for
all the Command Line Interface commands
8DG09019KAAA Alcatel-Lucent 1850 Transport Service Switch (TSS-320 and TSS160) Release 3.1 User Provisioning Guide. Provides general Craft Terminal information,
screens description and user provisioning procedures by means of the ZIC.
8DG09019JAAA Alcatel-Lucent 1850 Transport Service Switch (TSS-320 and TSS160) Release 3.1 Turn-Up & Commissioning Guide. Provides information on Turn-Up,
Tests and Operation procedures
8DG09021AAAA Alcatel-Lucent 1850 Transport Service Switch (TSS-320 and TSS160) Release 3.1 Documentation CD-ROM. It contains the electronic format of all the
above listed documents.

xii

Alcatel-Lucent - Proprietary
See notice on first page.

8DG09019HAAATQZZA
June 2009

Document support

For support in using this or any other Alcatel-Lucent document, contact Alcatel-Lucent at
one of the following telephone numbers:

1-888-582-3688 (for the United States)

1-317-377-8618 (for all other countries).

Technical support

For technical support, contact your local Alcatel-Lucent customer support team. See the
Alcatel-Lucent Support web site (http://alcatel-lucent.com/support) for contact
information.
How to order

To order Alcatel-Lucent documents, contact your local sales representative or use the
Online Customer Support Site (OLCS) web site (http://support.alcatel-lucent.com/).
How to comment

To comment on this document, go to the Online Comment Form (http://infodoc.alcatellucent.com/comments/) or e-mail your comments to the Comments Hotline (mailto:
comments@alcatel-lucent.com).
Packaging collection and recovery requirements

Countries, states, localities, or other jurisdictions may require that systems be established
for the return and/or collection of packaging waste from the consumer, or other end user,
or from the waste stream. Additionally, reuse, recovery, and/or recycling targets for the
return and/or collection of the packaging waste may be established.
For more information regarding collection and recovery of packaging and packaging
waste within specific jurisdictions, please contact the Alcatel-Lucent Field
Services/Installation - Environmental Health and Safety organization.
Preliminary checks

The following information should be printed on the outer crate:


International symbols
side up:
keep dry
fragile
8DG09019HAAATQZZA
June 2009

Alcatel-Lucent - Proprietary
See notice on first page.

xiii

Trade mark/address of the manufacturing company;


Labels (or templated marks) indicating information on the contract and destination site of
the product;
An envelope holding among others the packing list
Upon receipt check:
That the final destination of the crates is that indicated on the label;
that no damage was made to the cases
Report any shipping damages to the Companys representative or the Shipping Agent.
Unpacking

When having to unpack proceed as follows:


symbol;

Make sure that the packing has been properly positioned, refer to the
open the case;
remove the shockproof material;
remove the goods from the case;
remove prepacking, the polyethylene bag and any other protection;
remove the plastic bags cellotaped to the rack and containing accessories;
remove the dehydrating bags;

ascertain that the goods are not damaged and that they correspond to those indicated on
the packing list enclosed in the envelope. Conversely, contact the agencys
representative.
Note: When unpacking it is advisable to handle the packing material with care; it might
be reused for packing again if it must be reshipped.
Warehousing

If having to store the packed material, the following requirements must be met:
the cardboard boxes must be placed indoors in airy rooms;
the wooden or plywood cases can be placed outdoors, provided they are protected against
rain and direct sunlight.

xiv

Alcatel-Lucent - Proprietary
See notice on first page.

8DG09019HAAATQZZA
June 2009

Recycling/take-back/disposal of product

Electronic products bearing or referencing the symbol shown below, when put on the
market within the European Union, shall be collected and treated at the end of their
useful life in compliance with applicable European Union and local legislation. They
shall not be disposed of as part of unsorted municipal waste. Due to materials that may be
contained in the product, such as heavy metals or batteries, the environment and human
health may be negatively impacted as a result of inappropriate disposal.

Note: In the European Union, a solid bar under the crossed-out wheeled bin indicates that
the product was put on the market after 13 August 2005.
Moreover, in compliance with legal requirements and contractual agreements, where
applicable, Alcatel-Lucent will offer to provide for the collection and treatment of
Alcatel-Lucent products at the end of their useful life. Alcatel-Lucent will also offer to
provide for the collection and treatment of existing products displaced by Alcatel-Lucent
equipment.
For information regarding take-back of equipment by Alcatel-Lucent, or for more
information regarding the requirements for recycling/disposal of product, please contact
your Alcatel-Lucent Account Manager or Alcatel-Lucent Take-Back Support at
takeback@alcatel-lucent.com.

8DG09019HAAATQZZA
June 2009

Alcatel-Lucent - Proprietary
See notice on first page.

xv

Mechanical installation of
shelves into the AlcatelLucent TSS ETSI rack

Overview
Purpose

This chapter describes the mechanical installation of shelves into the Alcatel-Lucent
ETSI rack.
Contents

This chapter contains the following:


Mechanical installation of the Alcatel-Lucent 1850 TSS-320 subrack into
the TSS rack

1-2

Mechanical installation of the Alcatel-Lucent 1850 TSS-160 sub-rack into


the TSS rack

1-15

8DG09019HAAATQZZA
June 2009

Alcatel-Lucent Proprietary
See notice on first page.

1-1

Mechanical installation of the Alcatel-Lucent 1850 TSS-320


subrack into the TSS rack
Alcatel-Lucent 1850 TSS-320 shelf insertion into the rack

(See Figure 1 and Figure 2).


A max. of 2 Alcatel-Lucent 1850 TSS-320 subracks can be mounted in an Alcatel-Lucent
1850 TSS rack.
At the beginning of the sub-rack installation the brackets (1) must be moved to another
position in the rack not occupied by the sub-rack.
The Figure 1 shows the brackets assembly (1).

Figure 1 Bracket assembling


1-2

Alcatel-Lucent - Proprietary
See notice on first page.

8DG09019HAAATQZZA
June 2009

To mount the subrack into the rack use the screws and washers supplied in the
subrackinstallation kit code 8DG08845AA.
Fasten the subrack to the rack by inserting the screws and the washers into the holes on
the brackets of the rack.
The position of subrack in the rack depends on the position of the other shelves that have
to be inserted into the same rack..
It is necessary to leave some space for the air deflector.
Once the sub-rack is installed, install the right bracket (code 3AL92508AA) and the left
bracket (code 3AL92507AA) which are included in the installation kit code
8DG08845AA. Fix them by means of the 3+3 M6x12 screws (see Figure 2 on page 1-2).

Screw M6x12

Bracket

Figure 2 Bracket assembling

8DG09019HAAATQZZA
June 2009

Alcatel-Lucent - Proprietary
See notice on first page.

1-3

ETSI air deflector mounting

The next paragraphs are related to the installation of the air deflector.
Lower baffle installation (code 8DG08834AA)

This baffle has to be mounted below each Alcatel-Lucent 1850 TSS-320 subrack after the
subracks are installed.
Standard position
H = 100 mm

H
2
3

1
Lower scoop
mounting screws

2
3

2
3

H = 125 mm

Lower scoop position:


1 Not used H = 75 mm
2 Standard position H = 100 mm
3 H = 125 mm

Figure 3 Lower baffle

1-4

Alcatel-Lucent - Proprietary
See notice on first page.

8DG09019HAAATQZZA
June 2009

Procedure

Proceed as follows:

1 Place the lower baffle below each Alcatel-Lucent 1850 TSS-320 subrack using the last
holes of the mounting bracket (see Figure 4).
2 Insert the four (4) M6 screws and star washers supplied with the lower baffle. It may be
necessary to open the front cover to access the mounting screws.
3 Tighten all the screws (for torque value, refer to Appendix G, Tightening torque.
END OF STEPS

Figure 4 Lower baffle view

8DG09019HAAATQZZA
June 2009

Alcatel-Lucent - Proprietary
See notice on first page.

1-5

Upper baffle installation (code 8DG08844AA)


Upper heat baffle mount

Important! This baffle has to be mounted on the upper subrack ONLY. The lower
subrack does NOT use this part.

Figure 5 Upper baffle

1-6

Alcatel-Lucent - Proprietary
See notice on first page.

8DG09019HAAATQZZA
June 2009

Procedure

Proceed as follows:

1 Install the upper baffle on the top of the upper Alcatel-Lucent 1850 TSS-320 subrack
only
2 Insert the two (2) M6 screws supplied with the upper baffle.
3 Tighten all the screws (for torque value, refer to Appendix G, Tightening torque).
END OF STEPS

The upper heat baffle (code 8DG08844AA) is provided with a removable front cover that
is mounted by two (2) captive fasteners, as shown in Figure 6. It is possible to have two
baffles cover dimensions to use in accordance with the space that there is between the
equipments assembled on the rack, as shown in Figure 6 and Figure 7.

H=100 mm

Qty 2 captive fasteners

H=138 mm

Figure 6 Upper baffle standard position H=100 mm

Figure 7 Upper baffle H=138 mm

8DG09019HAAATQZZA
June 2009

Alcatel-Lucent - Proprietary
See notice on first page.

1-7

FANS connections

Insert the FAN units (P/N 8DG90031AB) into slot 40, the top part of the subrack, and
slot 41, the bottom part of the subrack.

Do NOT use any tools to install the FAN unit. See Figure 8.

Lower FAN unit

Lower baffle

Figure 8 FAN connections

Once the lower FAN unit has been inserted in the shelf, it is necessary to install the
protection grid (code 3AL94613AA) under the FAN tray.

1-8

Alcatel-Lucent - Proprietary
See notice on first page.

8DG09019HAAATQZZA
June 2009

Air filter grid maintenance (only for dust concentration more then 400mg/m3)

In order to have the correct air flow in the shelf, the air filter (code 8DG16694AB) which
is installed on the lower baffle grid that is placed below the FAN unit, shall be cleaned
every 3 months.

Figure 9 Removing protection grid

Air Filter

Figure 10 Removing Air Filter

8DG09019HAAATQZZA
June 2009

Alcatel-Lucent - Proprietary
See notice on first page.

1-9

Mechanical adaptation to various board sizes

The Alcatel-Lucent 1850 TSS-320 shelf allows several size of boards:

Large boards (353 mm high 22,5 mm large)

Small boards (159 mm high 22,5 mm large)

boards (265 mm high 22,5 mm large)

double boards (265 mm high 45 mm large)

A mechanical part is used to separate a Large slot into a small one. Three types of
mechanical adapter exist:

Half-slot adapter (P/N 8DG87289AAAA) to use small boards

slot adapter (P/N 8DG07710AAAA) to use boards

double slot adapter (P/N 8DG07581AAAA) to use double boards.

All empty slots must be filled with dummy plates in order to keep good air flow in the
shelf.
The references are:

1-10

1
2

EQUICO Dummy plate:


SERVICE Dummy plate:

3AL92159AA
3AL92160AA

FULL Slot Dummy plate:

3AL92154AB

HALF Slot Dummy plate

3AL92156AB

5
6

Slot Dummy Plate


Slot Dummy Plate

8DG07751AA
8DG07705AA

Alcatel-Lucent - Proprietary
See notice on first page.

8DG09019HAAATQZZA
June 2009

Half-slot adapter installation rules

The following instructions are related to the half-slot adapter installation.

Figure 11 Half-slot adapter


In order to avoid damaging or short circuits on the units already installed on the sub-rack,
it is necessary the use of the tool code 8DG07796AAAA (see Figure 12).

Figure 12 Tool code 8DG07796AAAA

8DG09019HAAATQZZA
June 2009

Alcatel-Lucent - Proprietary
See notice on first page.

1-11

Move and fix detail B to the position shown in Figure 13.

Figure 13 Position of Detail B


2

Insert the tool in the sub-rack guide; see Figure 14.

Tool

Figure 14 Tool 8DG07796AAAA insertion with subrack

1-12

Alcatel-Lucent - Proprietary
See notice on first page.

8DG09019HAAATQZZA
June 2009

Insert the half-slot adapter in the tool slot and attach it to the back-panel by means of
the screwdriver (code 1AD008610003). See Figure 15.

Tool

Half-slot
adapter

Long
Screwdriver

Figure 15 Half slot installation


4)

Extract the tool by the sub-rack, see Figure 16.

Tool
extraction

Figure 16 Removal of the tool 8DG07796AAAA

8DG09019HAAATQZZA
June 2009

Alcatel-Lucent - Proprietary
See notice on first page.

1-13

Figure 17 Half-slot adapter installed

1-14

Alcatel-Lucent - Proprietary
See notice on first page.

8DG09019HAAATQZZA
June 2009

Mechanical installation of the Alcatel-Lucent 1850 TSS-160


sub-rack into the TSS rack
Alcatel-Lucent 1850 TSS-160 shelf insertion into the rack

See Figure 18 and Figure 19.


A maximum of three (3) Alcatel-Lucent 1850 TSS-160 sub-racks can be mounted in an
Alcatel-Lucent 1850 TSS rack.
At the beginning of the sub-rack installation, the brackets (1) must be moved to another
position in the rack which is not occupied by the sub-rack.
Figure 18 shows the brackets assembly (1).

Figure 18 Bracket assembling


8DG09019HAAATQZZA
June 2009

Alcatel-Lucent - Proprietary
See notice on first page.

1-15

To install the subrack TSS 160 into the rack, make use of the following:

Left support code 8DG87273AAAA

Right support code 8DG87277AAAA

Screw M6x12 q.ty 6 code 1AD009150001

Washers code 1AD000900008 (qty. 6) and code 1AD000870136( qty 6).

All these materials are included in TSS-160 installation ETSI kit (code 8DG87321AA).
Place and fix the subrack to the rack using the screws and washers as shown in
19.

Figure

Figure 19 Alcatel-Lucent 1850 TSS-160 sub-rack insertion into the rack

1-16

Alcatel-Lucent - Proprietary
See notice on first page.

8DG09019HAAATQZZA
June 2009

Note: TSS-160 grounding

GND connection
point

Figure 20 GND Connection point

If requested ground the TSS-160 Shelf using a 6 mm2 Ye/Gr cable terminated with the
lug 1AB035020001, shown in Figure 21 1850 TSS-160 cover assembling. Connected
the other side of this cable to the ground connection point placed at the top of the rack.

8DG09019HAAATQZZA
June 2009

Alcatel-Lucent - Proprietary
See notice on first page.

1-17

Assembly the front cover code 8DG87337AA, as described in the following steps and
shown in Figure 21 1850 TSS-160 cover assembling

Fix the cover extension code 8DG87380AA to the lower part of the cover by 2
brackets code 8DG87337AA and 8 M4 nuts and 8 washers

Repeat the same operation for the upper part.

Place and fix the cover on the subrack by 2 captive screws


Upper cover
extension

Cover

Front view

Rear view
Lower cover
extension

Braket
Captive
screws

Figure 21 1850 TSS-160 cover assembling

All these materials are included in TSS-160 installation ETSI kit (code 8DG87321AA).

1-18

Alcatel-Lucent - Proprietary
See notice on first page.

8DG09019HAAATQZZA
June 2009

ETSI Air deflector mounting

To guarantee the correct airflow, it is necessary to assemble, above and below the
subrack, two air deflectors.

Air deflectors

Air deflectors
fixing screws

Figure 22 Air deflector mounting

If two TSS-160 subracks are present in the rack one above the other, mount only one air
deflector and the related front cover part, between the two shelves.

8DG09019HAAATQZZA
June 2009

Alcatel-Lucent - Proprietary
See notice on first page.

1-19

The air deflector is made of two parts: bracket and plate (see Figure 23). Both are
included in kit code 8DG87321AA.
The upper air deflector installation to the sub-rack is made by the two screws already
present on the sub-rack. See Figure 23.
The lower air deflector installation to the sub-rack is made by two bolts as shown in
Figure 24.

Bracket

Plate
Figure 23 TSS-160 Air deflector

1-20

Alcatel-Lucent - Proprietary
See notice on first page.

8DG09019HAAATQZZA
June 2009

Fixing bolts

Lower air deflector

Figure 24 Fixing lower Air deflector

8DG09019HAAATQZZA
June 2009

Alcatel-Lucent - Proprietary
See notice on first page.

1-21

The deflectors position can be adjusted by the three screws M2.5x6, see
Figure 25.
Minimum length = 160mm
Maximum length = 180 mm
The deflector must be adjusted in order to reach the other sub-racks placed under or over
the Alcatel-Lucent 1850 TSS-160 sub-rack.
M2,5x6 screws

Figure 25 Air deflector adjusting screws

1-22

Alcatel-Lucent - Proprietary
See notice on first page.

8DG09019HAAATQZZA
June 2009

Alcatel-Lucent 1850 TSS-160 FAN connections

Insert the FAN units (P/N 8DG87202AA) into slot 40 (top/left part of the sub-rack) and
slot 41 bottom/left part of the sub-rack.
Do NOT use any tools to install the FAN unit. See Figure 26.

Air Grid

Detail A
See Air grid
maintenance
FAN

Figure 26 FAN connections


Once the FAN unit has been inserted in the shelf, it is necessary to install the Air grid.

8DG09019HAAATQZZA
June 2009

Alcatel-Lucent - Proprietary
See notice on first page.

1-23

Air Grid maintenance (suggested every 6 months)

To remove the grid, proceed as follows:


1 Loose the two knobs A.
2

Move the plate B.

Draw out the grid as shown in the following figures.

Plate B

Knobs A

Grid

Figure 27 Protection grid maintenance

Figure 28 Open the cover plate

1-24

Alcatel-Lucent - Proprietary
See notice on first page.

8DG09019HAAATQZZA
June 2009

Figure 29 Open the cover plate

Figure 30 Remove the grid

8DG09019HAAATQZZA
June 2009

Alcatel-Lucent - Proprietary
See notice on first page.

1-25

Mechanical adaptation to various board sizes

The Alcatel-Lucent 1850 TSS-160 shelf allows several size of boards:

Large boards (353 mm high 25 mm large)

Small boards (159 mm high 25 mm large)

A mechanical part is used to separate a Large slot into a small one. One type of
mechanical adapter exists:

Half-slot adapter (P/N 8DG87289AAAA) to use small boards

All empty slots must be filled with dummy plates in order to keep good air flow in the
shelf.
The references are:

1-26

EQUICO Dummy plate:

3AL92159AA

2
3

FULL Slot Dummy plate:


HALF Slot Dummy plate

3AL92154AB
3AL92156AB

Alcatel-Lucent - Proprietary
See notice on first page.

8DG09019HAAATQZZA
June 2009

Mechanical installation of the EMI-FILTER and GENTRU


To assemble the EMI FILTER and GENTRU on the rack, it is necessary to use the relative
installation kits codes 8DG08847AA and 8DG08216AA.
To assemble the EMI FILTER and GENTRU, proceed as follows:
a) Place and fix the filter support (code 8DG08880AAAA) to the rack with 6 screws (M6x12mm)
and 6 washers.
b) Place and fix the GENTRU to the rack with 4 screws (M6x12mm).
c) Place and fix the EMI FILTER on the support and GENTRU as shown in figure below. The fine
terminals of the EMI-FILTER must be fixed by 5 screws M6x12 using a socket wrench.
Qty. 3
screws M3
EMI
FILTER
FILTER
SUPPORT

GENTRU
Qty. 5
screws M6x12

Figure 31: EMI FILTER and GENTRU connection

8DG09019HAAATQZZA
June 2009

Alcatel-Lucent - Proprietary
See notice on first page.

1-27

Mechanical installation of the MA-NGTRU


To assemble the MA-NGTRU on the rack, place and fix the MA-NGTRU to the rack with
4 screws (M6x12mm) as shown in Figure 32 MA-NGTRU insertion into the rack. All the
materials are part of the kit code 3AL92196AA.

T.B.D.

Figure 32 MA-NGTRU insertion into the rack

1-28

Alcatel-Lucent - Proprietary
See notice on first page.

8DG09019HAAATQZZA
June 2009

Electrical installation rules

Overview
Description

Installation must be executed without powering the equipment.


Ground connection protection must be the first operation.
The power supply connection must be the last to be executed.
The electrical wiring is located directly on the boards front plate PSF320, EC320, and
MATRIX, and on the upper side of the Back Panel TSS-320 and over the sub-rack TSS160 for the common parts.
Electrica SFP modules can be plugged on data units (see 2-13)
The optical connections are directly wired on the units.
Figure 38 on page 2-11 illustrates all the connection points on the TSS-320 equipment.
Figure 84 on page 2-66 illustrates all the connection points on the TSS-160 equipment.
To properly install the cable and fiber inside the rack, use the spaces shown in Figure 33
on page 2-3.
Contents

This chapter contains the following:

8DG 08763 FAAA


April 2009

Alcatel-Lucent 1850 TSS-320 boards installation

2-10

Alcatel-Lucent 1850 TSS-320 connection points - common units

2-11

Alcatel-Lucent 1850 TSS-320 connection points - SDH units

2-12

Alcatel-Lucent 1850 TSS-320 connection points - DATA units

2-15

Alcatel-Lucent 1850 TSS-320 connection points Optical Amplifier units

2-18

Alcatel-Lucent - Proprietary
See notice on first page.

2-1

2-2

Alcatel-Lucent 1850 TSS-320 connection points - DWDM units

2-19

Alcatel-Lucent 1850 TSS-320 connection points CWDM units

2-21

Power supply & synchronization

2-24

EC320 unit connection

2-38

MATRIX unit connection

2-39

Back panel electrical connections

2-46

Fiber routing

2-63

Alcatel-Lucent 1850 TSS-320 boards installation and electrical


connections

2-10

Alcatel-Lucent 1850 TSS-160 connection points - common units

2-65

Alcatel-Lucent 1850TSS-160 connection points - SDH units

2-67

Alcatel-Lucent 1850 TSS-160 connection points DATA units

2-70

Alcatel-Lucent 1850 TSS-160 connection points DWDM units

2-74

Power supply & synchronization

2-77

EC320 unit connection

2-96

MATRIX unit connection

2-97

Electrical connections

2-103

Fiber routing

2-111

Fiber conveyor

2-112

Optical jumper routing

2-113

Alcatel-Lucent - Proprietary
See notice on first page.

8DG09019HAAATQZZA
June 2009

Side holder

Cable Area

Side holder

TOP VIEW

Fiber area

FRONT OF THE VIEW

Fiber area

Figure 33 Basic wiring areas


Note: The side holders are supplied together with the rack and are used to fasten the
electrical cable inside the rack upright.
The position of the side holders depends of the position of the shelves.
Figure 34 on page 2-4 illustrates an Alcatel-Lucent 1850 TSS rack equipped with two
Alcatel-Lucent 1850 TSS-320 sub-racks (recommended configuration).
Figure 35 on page 2-5 illustrates an Alcatel-Lucent 1850 TSS rack equipped with one
Alcatel-Lucent 1850 TSS-320 sub-rack and one Alcatel-Lucent 1850 TSS-160.
Figure 36 on page 2-6 illustrates an Alcatel-Lucent 1850 TSS rack equipped with three
Alcatel-Lucent 1850 TSS-160 sub-racks and GENTRU.
Figure 34 Rack ETSI layout with two TSS-320s on page 2-4 illustrates an AlcatelLucent 1850 TSS rack equipped with three Alcatel-Lucent 1850 TSS-160 sub-racks and
MANGTRU.

8DG09019HAAATQZZA
June 2009

Alcatel-Lucent - Proprietary
See notice on first page.

2-3

The height of the upper


baffle is 100mm

Figure 34 Rack ETSI layout with two TSS-320s

2-4

Alcatel-Lucent - Proprietary
See notice on first page.

8DG09019HAAATQZZA
June 2009

The height of the upper


baffle is 100mm

TSS-160
AIR BAFFLE

TSS-160
AIR BAFFLE

Figure 35 Rack ETSI layout with TSS-320 + TSS-160

8DG09019HAAATQZZA
June 2009

Alcatel-Lucent - Proprietary
See notice on first page.

2-5

NB

Figure 36 Rack ETSI layout with three TSS-160s


NB: Mount only one air deflector between the two shelves and only the lower cover extension

2-6

Alcatel-Lucent - Proprietary
See notice on first page.

8DG09019HAAATQZZA
June 2009

MA_NGTRU

NB

Figure 37 Rack ETSI layout with three TSS-160s and MA-NGTRU

NB: Mount only one air deflector between the two shelves and only the lower cover extension

8DG09019HAAATQZZA
June 2009

Alcatel-Lucent - Proprietary
See notice on first page.

2-7

Figure 34, Figure 35, and Figure 36 show the possible rack lay-out configuration.
The assembly sequence for a correct installation of the sub-racks into the rack depends on
which direction the cables originate from:

If the cables originate from the bottom, the first subrack must be assembled on the
top of the rack

If the cables originate from the top, the first subrack must be assembled on the
bottom of the rack

All the intershelves optical connections always run through the cable ducts that are
vertically placed on the racks as shown in Figure 34, Figure 35 and Figure 36 on page 24, 2-5, and 2-6.

Power consumption, cable section and rack configuration

n 1 1850 TSS-320
n 2 1850 TSS-320
n 1 1850 TSS-160

Max Power
Consumption
3,5 KW max
7 KW max
2 KW max

n 2 1850 TSS-160
n 3 1850 TSS-160

Rack Configuration

n 1 1850 TSS-320 +
n 1 1850 TSS-160

Cable Section (NB) N Lines


25 mmq
25 mmq
16 mmq

1+1
2+2
1+1

4 KW max

16 mmq

2+2

6 KW max

16 mmq

3+3

5,5 KW max

25 mmq

2+2

TRU
GENTRU
GENTRU
MA-NGTRU
or GENTRU
MA-NGTRU
or GENTRU
MA-NGTRU
or GENTRU
GENTRU

N.B. The section of the cable must be calculated in the ETSI range temperature, in
accordance with Alcatel specification code 1AC 00106 0002 DSZZA.

2-8

Alcatel-Lucent - Proprietary
See notice on first page.

8DG09019HAAATQZZA
June 2009

Dummy Plate for correct air flow and heat dissipation

Plug the dummy plate into the empty slot before installation ends.
The relevant codes for the dummy plates are as follows:
8DG87270AAAA

FAN TRAY DUMMY PLATE

8DG08467AAAA

MATRIX DUMMY PLATE

3AL92159AAAA

EQUICO DUMMY PLATE

3AL92156ABAA

HALF SLOT DUMMY PLATE

3AL92154ABAA

FULL SLOT DUMMY PLATE

3AN51356ACAA

GENTRU DUMMY PLATE

3AN51356ABAA

MA-NGTRU DUMMY PLATE

8DG09019HAAATQZZA
June 2009

Alcatel-Lucent - Proprietary
See notice on first page.

2-9

Alcatel-Lucent 1850 TSS-320 boards installation and electrical


connections
Description

All the units pluggable in Alcatel Lucent 1850 TSS-320 equipments, are described in this
chapter.
The following paragraphs show the electrical connections points are reported for every
units.

2-10

Alcatel-Lucent - Proprietary
See notice on first page.

8DG09019HAAATQZZA
June 2009

Alcatel-Lucent 1850 TSS-320 connection points - common unit


RL

15

17

1
6

M1
RA

8
15

HOUSEKEEPING
OUT
1
IN
25
14
M4502
SHELF ID

13

5
9

M4503

15

1
M4504

16
STUPA STUPB

18

AUX CHANNELS
13

21

25
M4508

M4509

22

1
M4507

14

23

MT320N
MT320LO

EC320

PSF320

FAN

2
Slot 40,41

1
Slot 37, 39
Slot 1, 20

Slot 10, 11

Figure 38 Connection points for installation of Alcatel-Lucent 1850 TSS-320 common unit
The access points are reported on Table 1 on page 2-23.

8DG09019HAAATQZZA
June 2009

Alcatel-Lucent - Proprietary
See notice on first page.

2-11

Alcatel-Lucent 1850 TSS-320 connection points - SDH units

LOA10G

1P10GSO
NB2

Slot 21-22
24-33/
35-36

Slot 2-9/
12-19/
21-28/
29-36

4P2G5SO
NB3

Slot 2-9/
12-19/
21-28/
29-36

8PSO

10xANY

1POTU2

Slot 2-9/
12-19/
21-28/
29-36

Slot 2-9/
12-19/
21-28/
29-36

NB4

Slot 2-9/
12-19/
21-28/
29-36

Figure 39. Connection points for installation of Alcatel-Lucent 1850 TSS-320 - SDH
units
2-12

Alcatel-Lucent - Proprietary
See notice on first page.

8DG09019HAAATQZZA
June 2009

Note 1: For the installation of these boards in the sub-rack, use the half-slot adapter.
Note 2: The table below lists the relationship between the boards and modules.
Board
8PSO/10xANY
4P2G5SO/10xANY
4P2G5SO/10xANY
4P2G5SO/10xANY
4P2G5SO/10xANY
4P2G5SO/10xANY
4P2G5SO/10xANY
4P2G5SO/10xANY
8PSO/10xANY
8PSO/10xANY
4P2G5SO/10xANY
4P2G5SO/10xANY
4P2G5SO/10xANY
4P2G5SO/10xANY
4P2G5SO/10xANY
8PSO/10xANY
8PSO/10xANY
1P10GSO
8PSO/10xANY
4P2G5SO/10xANY
8PSO/10xANY
4P2G5SO/10xANY
4P2G5SO/10xANY
4P2G5SO/10xANY
4P2G5SO/10xANY
4P2G5SO/10xANY
4P2G5SO/10xANY
4P2G5SO/10xANY
4P2G5SO/10xANY
4P2G5SO/10xANY
1P10GSO
8PSO/10xANY
1P10GSO
1P10GSO
1P10GSO
1P10GSO
1P10GSO
1P10GSO
1P10GSO/10xANY
1P10GSO
1P10GSO
1P10GSO
8DG09019HAAATQZZA
June 2009

Module code
1AB196360006
1AB196350028
1AB196350029
1AB196350030
1AB196350031
1AB196350032
1AB196350033
1AB196370013
1AB196360005
1AB196360007
1AB196370005
1AB196370006
1AB196370007
1AB196370008
1AB196370009
1AB196360004
1AB194670007
1AB356630041
1AB194670004
1AB196350027
1AB194670006
1AB196350026
1AB196340009
1AB196340010
1AB196340011
1AB196340012
1AB196340013
1AB196340014
1AB196340015
1AB196340016
1AB356630039
1AB194670005
1AB356630023
1AB356630034
1AB356630031
1AB214540001
1AB217280001
1AB356630040
1AB253330001
1AB356630024
1AB356630025
1AB356630026

Module description
OPTO TRX SFP L-4.1 DDM -40/+85
CWDM 1510NM APD SFP DDM
CWDM 1530NM APD SFP DDM
CWDM 1550NM APD SFP DDM
CWDM 1570NM APD SFP DDM
CWDM 1590NM APD SFP DDM
CWDM 1610NM APD SFP DDM
OPTO TRX SFP I-16.1 DDM -40/+85
OPTO TRX SFP S-4.1 DDM -40/+85
OPTO TRX SFP L-4.2 DDM -40/+85
OPTO TRX SFP I-16.1 DDM
OPTO TRX SFP S-16.1 DDM -5/+85
OPTO TRX SFP S-16.1 ANYRATE DDM
OPTO TRX SFP L-16.1 DDM -5/+80
OPTO TRX SFP L-16.2 DDM -5/+80
OPTO TRX SFP S-4.1 DDM
OPTO TRX SFP S-1.1 DDM -40/+85
OE-TRX XFP DWDM CH20
OPTO TRX SFP S-1.1 DDM
CWDM 1490NM APD SFP DDM
OPTO TRX SFP L-1.2 DDM -40/+85
CWDM 1470NM APD SFP DDM
CWDM 1470NM PIN SFP DDM
CWDM 1490NM PIN SFP DDM
CWDM 1510NM PIN SFP DDM
CWDM 1530NM PIN SFP DDM
CWDM 1550NM PIN SFP DDM
CWDM 1570NM PIN SFP DDM
CWDM 1590NM PIN SFP DDM
CWDM 1610NM PIN SFP DDM
OE-TRX XFP DWDM CH22
OPTO TRX SFP L-1.1 DDM -40/+85
OE-TRX XFP DWDM CH38
OE-TRX XFP DWDM CH27
OE-TRX XFP DWDM CH30
XFP I-64.1/10GBE BASE L
XFP S64-2B/10GBE BASE E
OE-TRX XFP DWDM CH21
XFP-E P1L1-2D2
OE-TRX XFP DWDM CH37
OE-TRX XFP DWDM CH36
OE-TRX XFP DWDM CH35
Alcatel-Lucent - Proprietary
See notice on first page.

SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
2-13

Board
1P10GSO
1P10GSO
1P10GSO
1P10GSO
1P10GSO
1P10GSO
1P10GSO
1P10GSO
1P10GSO
1P10GSO
1P10GSO
1P10GSO
1P10GSO
1P10GSO
1P10GSO
1P10GSO
1P10GSO
10xANY

Module code
1AB356630027
1AB356630028
1AB356630029
1AB217280002
1AB356630036
1AB356630030
1AB356630038
1AB356630033
1AB356630035
1AB378370001
1AB378370002
1AB378370003
1AB378370004
1AB378370005
1AB378370006
1AB378370007
1AB378370008
1AB357990001

Module description
OE-TRX XFP DWDM CH34
OE-TRX XFP DWDM CH33
OE-TRX XFP DWDM CH32
XFP P1L1-2D2
OE-TRX XFP DWDM CH25
OE-TRX XFP DWDM CH31
OE-TRX XFP DWDM CH23
OE-TRX XFP DWDM CH28
OE-TRX XFP DWDM CH26
TRX XFP CWDM-LH CH47
TRX XFP CWDM-LH CH49
TRX XFP CWDM-LH CH51
TRX XFP CWDM-LH CH53
TRX XFP CWDM-LH CH55
TRX XFP CWDM-LH CH57
TRX XFP CWDM-LH CH59
TRX XFP CWDM-LH CH61
TRX SFP 100B FX DET

SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES

Yellow denotes the modules that need adapter code 3AL91721AA in order to be assembled in the
board.

The access points are reported on Table 1 on page 2-23.

2-14

Alcatel-Lucent - Proprietary
See notice on first page.

8DG09019HAAATQZZA
June 2009

Alcatel-Lucent 1850 TSS-320 connection points - DATA units

PP10MS

PP1GE

PP1GESY

PP10GE

PP10GESY

24

24

24

25

25

25

Slot 2-9, 12-19

Slot 2-9, 12-19

Slot 2-9, 12-19

Figure 40 Connection points for installation of Alcatel-Lucent 1850 TSS-320 DATA units

8DG09019HAAATQZZA
June 2009

Alcatel-Lucent - Proprietary
See notice on first page.

2-15

Note: The following table reports the relation between the boards and modules.
Board
PP1GE/PP1GESY
PP1GE/PP1GESY
PP1GE/PP1GESY
PP1GE/PP1GESY
PP1GE/PP1GESY
PP1GE/PP1GESY
PP10GE/PP10GESY
PP10GE/PP10GESY
PP10GE/PP10GESY
PP1GE/PP1GESY
PP1GE/PP1GESY
PP1GE/PP1GESY
PP1GE/PP1GESY
PP1GE/PP1GESY
PP1GE/PP1GESY
PP1GE/PP1GESY
PP1GE/PP1GESY
PP1GE/PP1GESY
PP1GE/PP1GESY
PP1GE/PP1GESY
PP1GE/PP1GESY
PP1GE/PP1GESY
PP1GE/PP1GESY
PP1GE/PP1GESY
PP1GE/PP1GESY
PP1GE/PP1GESY
PP1GE/PP1GESY
PP10GE/PP10GESY
PP10GE/PP10GESY
PP10GE/PP10GESY
PP10GE/PP10GESY
PP10GE/PP10GESY
PP10GE/PP10GESY
PP10GE/PP10GESY
PP10GE/PP10GESY
PP10GE/PP10GESY
PP10GE/PP10GESY
PP10GE/PP10GESY
PP10GE/PP10GESY
PP10GE/PP10GESY
PP10GE/PP10GESY
PP10GE/PP10GESY
PP10GE/PP10GESY
PP10GE/PP10GESY
PP10GE/PP10GESY
2-16

Module code
1AB357990001
1AB187280031
1AB187280033
1AB187280040
1AB187280042
1AB187280045
1AB214540001
1AB214540002
1AB217280001
1AB359780001
1AB196350026
1AB196350027
1AB196350028
1AB196350029
1AB196350030
1AB196350031
1AB196350032
1AB196350033
1AB359780001
1AB196340009
1AB196340010
1AB196340011
1AB196340012
1AB196340013
1AB196340014
1AB196340015
1AB196340016
1AB356630023
1AB356630024
1AB356630025
1AB356630026
1AB356630027
1AB356630028
1AB356630029
1AB356630030
1AB356630031
1AB356630032
1AB356630033
1AB356630034
1AB356630035
1AB356630036
1AB356630037
1AB356630038
1AB356630039
1AB378370001

Module description
OE-TRX SFP 100B FX
OPTO TRX SFP 1GBE LX DDM
OPTO TRX SFP 1GBE SX DDM
OPTO TRX SFP 1.25GBE LX DDM -40/+85
OPTO TRX SFP 1GBE ZX DDM
OPTO TRX SFP 1.25GBE SX DDM -40/+85
XFP I-64.1/10GBE BASE L
XFP 10GBE BASE S (UP TO 10.3 GBS)
XFP S64-2B/10GBE BASE E
EL TRX SFP 1000BASE-T
SFP CWDM APD CH47 DDM
SFP CWDM APD CH49 DDM
SFP CWDM APD CH51 DDM
SFP CWDM APD CH53 DDM
SFP CWDM APD CH55 DDM
SFP CWDM APD CH57 DDM
SFP CWDM APD CH59 DDM
SFP CWDM APD CH61 DDM
TRX SFP 1000B Copper NB
SFP CWDM PIN CH47 DDM
SFP CWDM PIN CH49 DDM
SFP CWDM PIN CH51 DDM
SFP CWDM PIN CH53 DDM
SFP CWDM PIN CH55 DDM
SFP CWDM PIN CH57 DDM
SFP CWDM PIN CH59 DDM
SFP CWDM PIN CH61 DDM
TRX XFP 10G DWDM Ch38
TRX XFP 10G DWDM Ch37
TRX XFP 10G DWDM Ch36
TRX XFP 10G DWDM Ch35
TRX XFP 10G DWDM Ch34
TRX XFP 10G DWDM Ch33
TRX XFP 10G DWDM Ch32
TRX XFP 10G DWDM Ch31
TRX XFP 10G DWDM Ch30
TRX XFP 10G DWDM Ch29
TRX XFP 10G DWDM Ch28
TRX XFP 10G DWDM Ch27
TRX XFP 10G DWDM Ch26
TRX XFP 10G DWDM Ch25
TRX XFP 10G DWDM Ch24
TRX XFP 10G DWDM Ch23
TRX XFP 10G DWDM Ch22
TRX XFP CWDM-LH CH47
Alcatel-Lucent - Proprietary
See notice on first page.

SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
8DG09019HAAATQZZA
June 2009

Board
PP10GE/PP10GESY
PP10GE/PP10GESY
PP10GE/PP10GESY
PP10GE/PP10GESY
PP10GE/PP10GESY
PP10GE/PP10GESY
PP10GE/PP10GESY

Module code
1AB378370002
1AB378370003
1AB378370004
1AB378370005
1AB378370006
1AB378370007
1AB378370008

Module description
TRX XFP CWDM-LH CH49
TRX XFP CWDM-LH CH51
TRX XFP CWDM-LH CH53
TRX XFP CWDM-LH CH55
TRX XFP CWDM-LH CH57
TRX XFP CWDM-LH CH59
TRX XFP CWDM-LH CH61

SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES

Yellow denotes the modules that need adapter code 3AL91721AA in order to be assembled in the board.

PP10GE

PP10GESY

10

Note: The above picture denotes the numbering of the SFP modules that can be plugged
in the PP10GE/PP10GESY circuit pack.
The access points are reported in Table 1 on page 2-23.
NB : for these connection to use the cable code 1AC016760003 and the RJ45 connector
code 1AB074610008. For the cable assembly see page 2-37.

8DG09019HAAATQZZA
June 2009

Alcatel-Lucent - Proprietary
See notice on first page.

2-17

Alcatel-Lucent 1850 TSS-320 connection points Optical


Amplifier units

LOFA1111

Slot 6 9
12 - 15

BST10G

Slot 2 9
12 19
21 28
29 36

PR10G

Slot 2 9
12 19
21 28
29 36

Figure 41 Connection points for installation of Alcatel-Lucent 1850 TSS-320


Optical Amplifier units

2-18

Alcatel-Lucent - Proprietary
See notice on first page.

8DG09019HAAATQZZA
June 2009

Alcatel-Lucent 1850 TSS-320 connection points - DWDM unit

OMDX8100_L2_4G OMDX8100_L1_4G

DWLA10X

NB1

NB2

Slot 6 9,
12 - 15

Slot 6 9,
12 - 15

Slot 2 9
12 19
21 28
29 36

Figure 42 Connection points for installation of Alcatel-Lucent 1850 TSS-320 DWDM units
8DG09019HAAATQZZA
June 2009

Alcatel-Lucent - Proprietary
See notice on first page.

2-19

N.B.1 In this cavity (WDM/Line side), the following XFPs can be plugged
Board
DWLA10X
DWLA10X
DWLA10X
DWLA10X
DWLA10X
DWLA10X
DWLA10X
DWLA10X
DWLA10X
DWLA10X
DWLA10X
DWLA10X
DWLA10X
DWLA10X
DWLA10X
DWLA10X
DWLA10X
DWLA10X
DWLA10X

Module code
1AB356630023
1AB356630024
1AB356630025
1AB356630026
1AB356630027
1AB356630028
1AB356630029
1AB356630030
1AB356630031
1AB356630032
1AB356630033
1AB356630034
1AB356630035
1AB356630036
1AB356630037
1AB356630038
1AB356630039
1AB356630040
1AB356630041

Module description
TRX XFP 10G DWDM Ch38
SFP/XFP MODULES
TRX XFP 10G DWDM Ch37
SFP/XFP MODULES
TRX XFP 10G DWDM Ch36
SFP/XFP MODULES
TRX XFP 10G DWDM Ch35
SFP/XFP MODULES
TRX XFP 10G DWDM Ch34
SFP/XFP MODULES
TRX XFP 10G DWDM Ch33
SFP/XFP MODULES
TRX XFP 10G DWDM Ch32
SFP/XFP MODULES
TRX XFP 10G DWDM Ch31
SFP/XFP MODULES
TRX XFP 10G DWDM Ch30
SFP/XFP MODULES
TRX XFP 10G DWDM Ch29
SFP/XFP MODULES
TRX XFP 10G DWDM Ch28
SFP/XFP MODULES
TRX XFP 10G DWDM Ch27
SFP/XFP MODULES
TRX XFP 10G DWDM Ch26
SFP/XFP MODULES
TRX XFP 10G DWDM Ch25
SFP/XFP MODULES
TRX XFP 10G DWDM Ch24
SFP/XFP MODULES
TRX XFP 10G DWDM Ch23
SFP/XFP MODULES
TRX XFP 10G DWDM Ch22
SFP/XFP MODULES
TRX XFP 10G DWDM Ch21
SFP/XFP MODULES
TRX XFP 10G DWDM Ch20
SFP/XFP MODULES

Yellow denotes the modules that need adapter code 3AL91721AA in order to be assembled in the board.

N.B.2 In this cavity (client side), the following XFPs can be plugged
Board
DWLA10X
DWLA10X
DWLA10X

2-20

Module code
1AB214540001
1AB214540002
1AB217280001

TRX XFP I-64.1


TRX XFP 10GBASE-S
TRX XFP S-64.2

Module description
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES

Alcatel-Lucent - Proprietary
See notice on first page.

8DG09019HAAATQZZA
June 2009

Alcatel-Lucent 1850 TSS-320 connection points CWDM units

CMDX8 and CMDX8S

CADM4

CMDX2S CMDX1S

CADM1

CADM2

CWLA3

NB3
NB2
NB1

NB1

NB1

Slot 6-9/12-15

NB1

NB1

Slot 6-9/12-15

NB1

Slot 6-9/12-15

Figure 43 Connection points for installation of Alcatel-Lucent 1850 TSS-320


CWDM units
N.B.1 For the installation of these boards in the subrack, use the adapter 8DG07710AA
N.B.2 For the installation of this board in the subrack, use the adapter 8DG07781AA

8DG09019HAAATQZZA
June 2009

Alcatel-Lucent - Proprietary
See notice on first page.

2-21

N.B.3 The next table lists the SFP supported by CWLA3


Board
CWLA3
CWLA3
CWLA3
CWLA3
CWLA3
CWLA3
CWLA3
CWLA3
CWLA3
CWLA3
CWLA3
CWLA3
CWLA3
CWLA3
CWLA3
CWLA3
CWLA3
CWLA3
CWLA3
CWLA3
CWLA3

2-22

Module code
1AB196340016
1AB196340015
1AB196340014
1AB196340013
1AB196340012
1AB196340011
1AB196340010
1AB196340009
1AB196370013
1AB196370009
1AB196370008
1AB196370007
1AB196370005
1AB196350033
1AB196350032
1AB196350031
1AB196350030
1AB196350029
1AB196350028
1AB196350027
1AB196350026

Module description
CWDM 1610NM PIN SFP DDM
CWDM 1590NM PIN SFP DDM
CWDM 1570NM PIN SFP DDM
CWDM 1550NM PIN SFP DDM
CWDM 1530NM PIN SFP DDM
CWDM 1510NM PIN SFP DDM
CWDM 1490NM PIN SFP DDM
CWDM 1470NM PIN SFP DDM
OPTO TRX SFP I-16.1 DDM -40/+85
OPTO TRX SFP L-16.2 DDM -5/+80
OPTO TRX SFP L-16.1 DDM -5/+80
OPTO TRX SFP S-16.1 ANYRATE DDM
OPTO TRX SFP I-16.1 DDM
CWDM 1610NM APD SFP DDM
CWDM 1590NM APD SFP DDM
CWDM 1570NM APD SFP DDM
CWDM 1550NM APD SFP DDM
CWDM 1530NM APD SFP DDM
CWDM 1510NM APD SFP DDM
CWDM 1490NM APD SFP DDM
CWDM 1470NM APD SFP DDM

Alcatel-Lucent - Proprietary
See notice on first page.

SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES

8DG09019HAAATQZZA
June 2009

Table 1 Numbering, functions and paragraphs referred to the in TSS-320 connection


points
ACCESS
POINT

FUNCTION

FROM/TO

37, 39

Input Battery (PSF320)

37, 39

Synchronization connection

1, 20

10/100 ETH Debug RJ45 connector

1, 20

Local Craft Terminal connector


(RS232 F interface)

1, 20

RS232 on uUSB debug connector

1, 20

Local Craft Terminal connector


uUSB connector (F interface)

CT

1, 20

USB interface for external memory


device

PC

10, 11

uUSB Debug connector

Factory use only

10

10, 11

RJ45 Debug connector

Factory use only

11

10, 11

10/100 Mbit/s Q3 interface

DDF

12

10, 11

10/100 Mbit/s redundant Q3 interface

DDF

10, 11

ETH/FETH/GETH interface

Drop shelf
GENTRU

13

8DG09019HAAATQZZA
June 2009

SLOT

14

GENTRU
DDF
Factory use only
CT
Factory use only

15

Back Panel

Rack Lamp

16

Back Panel

Housekeeping

DDF

17

Back Panel

Rack Alarm

DDF

18

Back Panel

Shelf ID

21

Back Panel

Step up A Alarm

GENTRU

22

Back Panel

Step up B Alarm

GENTRU

23

Back Panel

Aux Channel

24

2-9
12-19l

RJ45 connector

Factory use only

25

2-9
12-19l

USB RS232 connector

Factory use only

Alcatel-Lucent - Proprietary
See notice on first page.

Termination

DDF

2-23

Power supply & synchronization


Description

The following paragraphs describe the power connections between Alcatel-Lucent 1850
TSS-320 and GENTRU.
Contents

This chapter contains the following:

2-24

Power supply connection

2-25

GENTRU power connection

2-27

Synchronization connections

2-32

Alcatel-Lucent - Proprietary
See notice on first page.

8DG09019HAAATQZZA
June 2009

Power supply connection


Description

Note: Before connecting the power supply, check that the related circuit breaker is open.
This chapter describes the power supply connection on the PSF320 board inserted into
slot 37 and 39 of the sub-rack.
Use the cable code 8DG08775AAAA inserted in the kit code 8DG08845AAAA (see
Annex A).
PSF320

PSF320 side

GENTRU side

Slot 37, 39

Figure 44 PSF320 side

8DG09019HAAATQZZA
June 2009

Alcatel-Lucent - Proprietary
See notice on first page.

2-25

Power cable routing

Connect the cable to the 5 subD connector placed on the PSF320 front plate.

The cables will be housed in the existing room above slot 37 and below the slot 39, as
shown in the following figure.

Cable routing

LOWER POWER CABLE

Cable routing

UPPER POWER CABLE


Figure 45 Electrical cables route

2-26

Both cables must be housed into the racks right duct. Fasten them to the related side
holder using waxed thread.

Connect the cables to subD connectors of the STEP UP unit. See the GENTRU power
connection section on the next page.

Alcatel-Lucent - Proprietary
See notice on first page.

8DG09019HAAATQZZA
June 2009

GENTRU power connection


Description

Assemble the EMI FILTER and GENTRU (using the relative installation kits codes
8DG08847AA and 8DG08216AA) on the rack. Connect the EMI FILTER to the GENTRU as
shown in Figure 46 and as described in the section, Mechanical installation of the EMI-FILTER
and GENTRU. Set the socket connectors (that are part of the GENTRU installation kit code
8DG08216AA) on the GENTRU as indicated in Figure 47.
Qty. 3
screws M3
EMI
FILTER

GENTRU
Qty. 5
screws M6x12

Figure 46 EMI FILTER and GENTRU connection

GENTRU socket setting configurations

M29

SLOTS 1

8DG09019HAAATQZZA
June 2009

M56

M65

Alcatel-Lucent - Proprietary
See notice on first page.

7
2-27

Here below the possible configurations of the GENTRU sockets


1)

L1,L2 and L3 are three different lines

M29
2)

M56

M65

L1 and L2 in parallel
3AL92210AAAA

M29
3)

M65

L1 and L3 in parallel

M29
4)

M56

M56

3AL92207AAAA

M65

L1, L2 and L3 in parallel

M29

M56

M65

.
Figure 47 GENTRU socket setting

Note: for 2), 3) and 4) the max power consumption of the line L1 must be 3,5 KW
Note: When the setting configurations are finished cover the sockets with the plastic
protection code 8DG07731AAAA

2-28

Alcatel-Lucent - Proprietary
See notice on first page.

8DG09019HAAATQZZA
June 2009

Insert in the GENTRU the STEP-UP A and B in slots 2 and 3. Connect the STEP-UP
cables and the Rack Lamp cable on the GENTRU.
For the STEP-UP connection, all the materials (Shell code 8DG08118AAAA, qty. 1;
SubD Female connector 5 wires - code 1AB040970018 - Qty. 1; and Contacts Crimp
3.8 mm code 1AB044280028, qty. 5 ) are included in the BOM of the power cable code
8DG08775AA. The power supply cable must be terminated and connected to the subD
connectors placed on the STEP-UP.
Figure 48 shows the power supply connectors pins, and Table 2 shows the related
function.
A1

A2

A3

A4

A5

Figure 48 STEP UP Output Power Connectors

Table 2 STEP-UP Output Power Connectors


PINS

SIGNALS

A1

Step-up positive output

A2

Step-up positive output

A3

GND

A4

Step-up negative output

A5

Step-up negative output

8DG09019HAAATQZZA
June 2009

Alcatel-Lucent - Proprietary
See notice on first page.

2-29

Crimp the 90 lug inserted in the GENTRU installation kit (code 8DG08216AA) on
the 25mm cables of the line A, line B, and GND from Central station, and connect
them to the EMI FILTER (as shown in Figure 49).

Table 3 Suggested cable


Code

Description

Cable color

1AC 00730 0055

Power cable 1x25 mm2

Black

1AC 03220 0001

Power cable 1x25 mm2

Red

1AC 03219 0001

Power cable 1x25 mm2

Blue

1AC 00780 0057

Power cable 1x25 mm2

Yellow/Green

Line A

Lugs

Line B

GND

Cover

Figure 49 Connection of Central station line cables to EMI FILTER


Note: The section of the cable must be calculated, in the ETSI range temperature, in
accordance with Alcatel specification code 1AC001060002 DSZZA.

2-30

Alcatel-Lucent - Proprietary
See notice on first page.

8DG09019HAAATQZZA
June 2009

GENTRU GND connections

Note : if the configuration foresee the installation of the third filter, it is necessary to
connect its GND point to the GND point of the second filter using the copper bar, part of
the installation kit (see Figure 50).

T.B.D.

Figure 50 GND EMI-FILTER connection


After the connection it is necessary to isolate the lugs as shown in Figure 51

Plastic
insulation
protection

Figure 51 Lugs insulation

8DG09019HAAATQZZA
June 2009

Alcatel-Lucent - Proprietary
See notice on first page.

2-31

Synchronization connections
Description

These connections are made by the adapter code 8DG08739AAAA and inserted into the
9-pin SubD connector placed on the front panel of the PSF320 board.

PSF320

Connector

Function

Output signal

Input signal

Cable
2

COAX ADAPTER
PSF320

A
2
B

Slot 37-39

Figure 52 PSF320 front plate connectors

The connections can be at 75 ohms (see next section 75-ohm synchronization) or 120
ohms (see next section, 20-ohm synchronization.

2-32

Alcatel-Lucent - Proprietary
See notice on first page.

8DG09019HAAATQZZA
June 2009

75-ohm synchronization coaxial cable

These connections are made with the cable 1AC001100013 equipped with 75-ohm
coaxial connector code 1AB061220018.
These connectors are included in kit 8DG08845AAAA.
The following figures show the assembling instruction for the coaxial connector.

1
2

Remove the insulation after the sign.


Push "A" in the cable.

Push the inner conductor "B" in the dielectric (small square).

Push the cable end in connector "C."

Push "A" in the connector and crimp (big hexagon).

crimp here

Figure 53 Cable 75 Ohm synchronization assembling instruction

8DG09019HAAATQZZA
June 2009

Alcatel-Lucent - Proprietary
See notice on first page.

2-33

120-ohm synchronization cable

For this type of connection, a cable like the one reported in Figure 54 on page 2-34 must
be built up in field.

1AC 00110 0013 Coax Cable


75 ohm 3.1 mm diam.

1AB 15834 0001 BALUN


1.0/2.3

Equipment
side

DDF
side

1AB 06122 0018 Male


Coax Conn 1.0/2.3 45

1AB 00979 0019 Female


Coax Conn 1.0/2.3

Shielded Twisted pair cable

Figure 54 120-ohm synchronization cable

For the connector 1AB 06122 0018 instructions, see the description on page 2-33.
For the connectors BALUN Male and Female, see assembling instructions for the
following manufacturers: Siemens and ITT CANNON
SIEMENS CONNECTOR:

(See Figure 55 on page 2-35)

Strip the cable. If no screen is available, then dimension 6 is not applicable and
dimension 13 becomes 11.

Unscrew ferrule (5) and remove insulator (3) and washer (4).

Push ferrule (5) over the cable.

Push a washer (4) over the screen and bend the screen back.

Push the second washer over the cable up to stop.

Cut the projecting screen to a length of about 2 mm max.

Insert the wires into holes A (correspondent with coax center conductor) and B of
insulator (3) and push the insulator up against the washer.

Spread open the wires and bend them over 180 laying into the cable duct.

Make sure that the end of the copper wires:


are laying parallel or bend toward the center of insulator
must not lay on to stop

2-34

Push the prepared cable onto body (1); by lining up the flat on the insulator with the
nose on the body.
Alcatel-Lucent - Proprietary
See notice on first page.

8DG09019HAAATQZZA
June 2009

Push on ferrule (5), screw on, and lightly tighten using 8-mm wrench.
(1)

(3)

(4)

(5)

(2)

Legenda:
1 - BODY
2 - IDC CONTACT
3 - INSULATOR
4 - WASHER
5 - FERRULE

13

6
2 mm max.

Figure 55 SIEMENS BALUN assembling instruction

8DG09019HAAATQZZA
June 2009

Alcatel-Lucent - Proprietary
See notice on first page.

2-35

ITT CANNON CONNECTOR:

(See Figure 56 on page 2-36)

Thread the plastic outer sleeve and pierce block onto the stripped cable.

Lay the insulated wires and drain wire in the appropriate slots in the pierce block and
trim excess wire flush with the underside of the flange.

Align the connector body with the plastic parts. Place them in the jaws of the
termination tool and close the tool to complete the assembly.
(1)

(2)

(3)

(4)

(5)

Legenda:
Signal

Screen
1 - BODY
2 - IDC CONTACT
3 - PIERCE BLOCK
4 - PLASTIC OUTER SLEEVE
5 - CABLE

Figure 56 ITT Cannon BALUN assembling instruction

2-36

Alcatel-Lucent - Proprietary
See notice on first page.

8DG09019HAAATQZZA
June 2009

Synchronization cable routing

This paragraph describes the correct installation route for the Synchronization cables; in
both cases, 75 ohm and 120 ohm.
Figure 57 on page 2-37 shows the correct cables route.
TO DDF

Cable for 120 ohm

(see Figure 54)

Cable 2 for
75 ohm
BALUN connector

Figure 57 Synchronization cable route

8DG09019HAAATQZZA
June 2009

Alcatel-Lucent - Proprietary
See notice on first page.

2-37

EC320 unit connection


Description

This paragraph describes all the electrical points available on the front panel of the EC
320 unit.
LEGENDA
(1)

(2)

(3)
(4)
(5)
(6)

BOARD STATUS MULTICOLOR LED:


LED OFF: card inserted and not running
AMBER BLINK: fpga download
GREEN BLINK: sw boot/self test
GREEN: CARD provisioned and running
RED: card fail
RED BLINK: card miss-configured or card missmatch
EPS MULTICOLOR LED:
GREEN: eps configured - card active
AMBER: eps configured - card stand- by
AMBER LINK: eps configured but not available
OFF: eps not configured
RESET COMMAND KEY
10/100 ETH DEBUG RJ45 CONNECTOR - factory use only
GREEN LED ON: full duplex
GREEN LED OFF: half duplex
YELLOW LED ON: link/active (no activity)
YELLOW LED BLINK: link/active (with activity)
YELLOW LED OFF: no link
RS232 on mUSB DEBUG CONNECTOR factory use

(7)
only
(8)
LOCAL CRAFT TERMINAL mUSB CONNECTOR (F
interface)
(9)
LOCAL CRAFT TERMINAL CONNECTOR (RS232 F
interface)
(10)
USB INTERFACE for external memory device
(11)
ALARM CUT-OFF KEY
(12)
LAMP TEST KEY
(13)
RED LED - critical alarm
(14)
RED LED - major alarm
(15)
ORANGE LED - minor alarm
(16)
ORANGE LED - warning alarm
(17)
RED LED - attended alarm
(18)
ORANGE LED - abnormal condition

ECA

Slot 1, 20

Figure 58 EC320 front plate unit connectors

.
2-38

Alcatel-Lucent - Proprietary
See notice on first page.

8DG09019HAAATQZZA
June 2009

MATRIX unit connection


Description

This paragraph describes all the electrical points available on the front panel of the
MT320N / MT320LO unit.
Contents

This paragraph contains the following:


LAN cables management route

8DG09019HAAATQZZA
June 2009

Alcatel-Lucent - Proprietary
See notice on first page.

2-36

2-39

LEGENDA

MT320N / MT320LO

(1)

EPS Multicolor LED:


GREEN: EPS configured - Card Active
AMBER: EPS configured - Card Stand-by
AMBER BLINK: EPS configured but not available
SWITCHED OFF: EPS not configured
(2)
BOARD STATUS Multicolor LED:
LED OFF: card inserted and not running
AMBER BLINK: fpga download
GREEN BLINK: sw boot/self test
GREEN: CARD provisioned and running
RED: card fail
RED BLINK: card miss-configured or card mismatch
(3)
Shelf Controller Restart Command Key
(4)
mUSB DEBUG connector - Factory use only
(5)
RJ45 DEBUG connector - Factory use only
(6) (9) (12)
GREEN LED ON: link/active (no activity)
GREEN LED BLINK: link/active (with activity)
GREEN LED OFF: no link
(7) (10) (13)
YELLOW LED ON: full duplex
YELLOW LED OFF: half duplex
YELLOW LED BLINKING: collision
(8)
10/100 Mbit/s Q3 interface
(11)
10/100 Mbit/s redundant Q3 interface
(14) (17) ETH/FETH/GETH interface for Drop Shelf
connection
(15) (18) Multicolor LED:
GREEN LED ON: 10/100 Mb/s link active (no activity)
GREEN LED BLINK: 10/100 Mb/s link active (with
activity)
ORANGE LED ON: 1000 Mb/s link active (no activity)
ORANGE LED BLINK: 1000 Mb/s link active (with
activity)
(16) (19)
YELLOW LED ON: full duplex
YELLOW LED OFF: half duplex
YELLOW LED BLINKING: collision

Slot 10, 11

Figure 59 Matrix front plate unit connectors

2-40

Alcatel-Lucent - Proprietary
See notice on first page.

8DG09019HAAATQZZA
June 2009

The LAN connections must be made with cable (code 1AC016760003) and the connector
RJ45 (code 1AB074610008) included in the installation kit (code 8DG08845AAAA).
The connector RJ45 assembly procedure is shown as follows.
Below are the instructions to assemble the cable (code 1AC016760003) with the
connector RJ45 (code 1AB074610008).
This port is suitable for the connections only to shielded intra-building cabling grounded
at both ends.
Assembly instructions
Slide the boot onto the cable (if needed).

Remove the outer jacket of the cable to the length shown in Figure 60. Take care not to
nick the shield or cut into any of the conductors.

Figure 60 Cable assembling cable instruction

Fold the cable shield (and the drain wire if present) back over the outer jacket as shown
in Figure 61.
Slide the shield onto the cable shield.
Take care that the shield remains on the cable shield.

Figure 61 Cable assembling cable instruction

8DG09019HAAATQZZA
June 2009

Alcatel-Lucent - Proprietary
See notice on first page.

2-41

Orientate the conductors in the desired sequence and trim off any excess length of the
conductors (refer to Figure 62).

Figure 62 Cable assembling cable instruction

Insert the cable into the plug as shown in Figure 63. Push the outer jacket towards the
Plug. Slide the shield onto the plug.

Figure 63 Cable assembling cable instruction

2-42

Alcatel-Lucent - Proprietary
See notice on first page.

8DG09019HAAATQZZA
June 2009

Reduce the length of the shielded pairs (refer to Figure 64).

Figure 64 Cable assembling cable instruction

For separating a pair, remove the shield foil from this pair outside the outer jacket.
Orientate the pairs in the desired sequence.
Reduce the foil of the other pairs. For best results in low crosstalk, take care to keep the
foil as long as possible (refer to Figure 65). The most important pair is the one between
the separated conductors.

Figure 65 Cable assembling instruction

8DG09019HAAATQZZA
June 2009

Alcatel-Lucent - Proprietary
See notice on first page.

2-43

Orientate the conductors in the desired sequence and trim off any excess length of the
conductors. Insert the cable into the plug (refer to Figure 66).
Push the outer jacket towards the Plug.
Slide the shield onto the plug.

Figure 66 Cable assembling instruction

Use the tools to crimp the strain relief, contacts, and ferrule.
For detailed information on the Molex application tool, see on Molex website or refer to
the catalogue.
Remove protruding cable shield.
Slide the boot onto the cable up to the dimension.
Solder the cable as reported on Table 4.

Table 4 Insertion wires table

PIN

1
2
3
4
5
6
7
8

2-44

Cable

White/Green
Green
White/Orange
Blue
White/Blue
Orange
White/Brown
Brown

Function

Pair 3
Pair 3
Pair 2
Pair 1
Pair 1
Pair 2
Pair 4
Pair 4

TXP (OUT)
TXN (OUT)
RXP (IN)
RXN (IN)

Alcatel-Lucent - Proprietary
See notice on first page.

8DG09019HAAATQZZA
June 2009

Management LAN cables routing

This paragraph describes the correct installation route for the LAN cables connected to
the MT320N / MT320LO unit.

Figure 67 Management LAN cable

8DG09019HAAATQZZA
June 2009

Alcatel-Lucent - Proprietary
See notice on first page.

2-45

Back panel electrical connections


Description

This paragraph describes all the electrical connections located on the upper side of the
Alcatel-Lucent 1850 TSS-320 equipment Back Panel.
Contents

This chapter contains the following:

2-46

Rack lamp connection

2-47

Remote alarm connection

2-50

Housekeeping connection

2-52

Shelf ID connection

2-54

STEP-UP connections

2-56

Auxiliary channel connection

2-60

Alcatel-Lucent - Proprietary
See notice on first page.

8DG09019HAAATQZZA
June 2009

Rack lamp connection


Description

These connections are made using the M1, 9 pins SUB D connector (see Figure 68 Detail A).
A
RL

HOUSEKEEPING
OUT
13
1
IN
25
14
M4502

5
9

1
6
M1
RA

STUPA STUPB

SHELF ID

AUX CHANNELS

13

15

15

25

14

M4503

M4504

M4507

M4508 M4509

Figure 68 Rack lamp connections

For this connection, use the cable code 8DG90079AAAA.


Rack lamps cable routing

The cable (code 8DG90079AAAA) (see Figure 69), once connected to connector M1 of
the back panel, must exit toward the rack left side (see Figure 70). Thereafter it must be
connected to M7, M8, M35, M36, M45, M46 of the GENTRU, using the RJ45 connector
(code 1AB 07461 0008) included in the installation kit (code 8DG08845AA).
This port is suitable for the connections only to shielded intra-building cabling grounded
at both ends.
View from A

A
RACK LAMP
CORD

Cable 049.720.430
1AC 01676 0003

M2

Connection table
Pair

Wire
White/Blue
Blue
White/Orange
Orange
White/Green
Green
White/Brown
Brown
Shielded cable braid

Cable stripping detail

Signals
M2
1
7
6
2
3
5
9
4
Case

NOT USED
RL_CH
NOT USED
NOT USED
RL_ATTD
RL_NURG
RL_REF
RL_URG

Figure 69 Rack lamp cable


8DG09019HAAATQZZA
June 2009

Alcatel-Lucent - Proprietary
See notice on first page.

2-47

To GENTRU

Figure 70 Rack lamp cable

Figure 71 shows the signal connection points related to RJ45 connector.

Figure 71 RJ45 connection points

2-48

Alcatel-Lucent - Proprietary
See notice on first page.

8DG09019HAAATQZZA
June 2009

Table 5 M7M8M35M36M45 and M46 extension alarm connector


Wire

Pins

Signals

Note

VSERV +

NOT USED

RL_CH

VSERV -

NOT USED

CANC

NOT USED

WHITE/GREEN

RL_ATTD

GREEN

RL_NURG

WHITE/BROWN

RL_REF

BROWN

RL_URG

9 and 10

GNDM

BLU

Table 6 Cable interconnection

8DG09019HAAATQZZA
June 2009

Cable DB9 (Figure 69)

Cable DB9 (Figure 69)

Alcatel-Lucent - Proprietary
See notice on first page.

2-49

Remote alarm connection


Description

These connections are made using M4503, 15 pins sub D connector (see Figure 72 Detail A).

RL
1

HOUSEKEEPING
OUT
1
IN
14
25
M4502

13

5
9

6
M1
RA

STUPA STUPB

SHELF ID

AUX CHANNELS

13

15

15

25

14

M4503

M4504

M4508

M4509

M4507

Figure 72 Remote alarm connections

Remote alarm cable routing

For these cable connections, the installation kit (code 8DG08845AA) comprise a 15-pin
connector (code 1AB003110022) with the related shell (code 1AB006030063). Use the
suggested cable code 1AC014910008.
This port is suitable for the connections only to shielded intra-building cabling grounded
at both ends.
The correct cable routing on the left side of the rack.
Table 7 shows the connections.

2-50

Alcatel-Lucent - Proprietary
See notice on first page.

8DG09019HAAATQZZA
June 2009

Table 7 Remote alarm cable pin-out

# Pin Signal

Description

Cable

RA_ANDBATT Fault or loss of both station batteries

RA_ORBATT Fault or loss of one station battery

RA_URG

Urgent alarm

RA_ANC

Fault or loss of both equipment-internal service power supplies

4
5
6
7

RA_NURG

Not urgent alarm

8
9

RA_ORC

Fault or loss of one equipment-internal service power supply

RA_INT

Internal alarm

RA_IND

Indeterminate alarm

15

RA_REF

Voltage reference of remote alarms

16

GND

Electrical ground - Case

17

GND

Electrical ground - Case

10
11
12
13
14

RA = Remote Alarm

8DG09019HAAATQZZA
June 2009

Alcatel-Lucent - Proprietary
See notice on first page.

2-51

Housekeeping connection
Description

These connections are made using M4502, 25 pins sub D connector (see Figure 73 Detail A).
A
RL
1
6

HOUSEKEEPING
OUT
13
1
IN
25
14
M4502

5
9
M1
RA

8
15
M4503

STUPA STUPB

SHELF ID
1

15

13

9
M4504

AUX CHANNELS
1

25
M4508 M4509

14

M4507

Figure 73 Housekeeping connections

Housekeeping cable routing

For these cable connections, the installation kit (code 8DG08845AA) comprise a 25-pin
connector (code 1AB003110023) with the related shell (code 1AB006030064). Use the
suggested cable code 1AC014910012.
This port is suitable for the connections only to shielded intra-building cabling grounded
at both ends.
The correct cable routing on the left side of the rack.
Table 8 shows the connections.

2-52

Alcatel-Lucent - Proprietary
See notice on first page.

8DG09019HAAATQZZA
June 2009

Table 8 Housekeeping connector pin-out

# Pin
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27

Signal

Description

HK_OUTN_1
HK_OUTP_1

# 1 Output; N wire
# 1 Output; P wire

HK_OUTN_2
HK_OUTP_2

# 2 Output; N wire
# 2 Output; P wire

HK_OUTN_3
HK_OUTP_3

# 3 Output; N wire
# 3 Output; P wire

HK_OUTN_4
HK_OUTP_4

# 4 Output; N wire
# 4 Output; P wire

Cable

6
HK_IN1
HK_IN2
HK_IN3
HK_IN4
HK_IN5
HK_IN6
HK_IN7
HK_IN8

# 1 Input
# 2 Input
# 3 Input
# 4 Input
# 5 Input
# 6 Input
# 7 Input
# 8 Input

HK_REF

Voltage reference of input housekeeping

GND
GND

Electrical ground - Case


Electrical ground - Case

HK = Housekeeping

8DG09019HAAATQZZA
June 2009

Alcatel-Lucent - Proprietary
See notice on first page.

2-53

Shelf ID connection
Description

These connections are made using M4504, 15 pins sub D connector (see Figure 74 Detail A).

RL

HOUSEKEEPING
OUT

13

25

M1

IN
M4502

RA

1
14
STUPA STUPB

SHELF ID

AUX CHANNELS

13

15

15

25

14

M4503

M4504

M4508

M4509

M4507

Figure 74 Shelf ID connections

Shelf ID connector

On this connector, it is necessary to plug in (on the Back Panel connector M4504) the
module code 3AL79242AAAA (see Figure 75).
Table 9 shows the connections.

2-54

Alcatel-Lucent - Proprietary
See notice on first page.

8DG09019HAAATQZZA
June 2009

Table 9 M4504 connector pin-out


# Pin

Signal

Description

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17

GND

Electrical ground

SHELF_ID0

Shelf ID bit 0

SHELF_ID1

Shelf ID bit 1

SHELF_ID2
SHELF_ID3

Shelf ID bit 2
Shelf ID bit 3

SHELF_ID4

Shelf ID bit 4

SHELF_ID5

Shelf ID bit 5

SHELF_ID6
SHELF_ID7
GND
GND

Shelf ID bit 6
Shelf ID bit 7
Electrical ground - Case
Electrical ground - Case

Figure 75 Shelf ID module

Rotating
switches
(Note)

Figure 76 Shelf ID module rotating switches


Note: Sett the position FF on rotating switches for Not installed shelf identification
(see Figure 76).
8DG09019HAAATQZZA
June 2009

Alcatel-Lucent - Proprietary
See notice on first page.

2-55

STEP-UP connections
Description

These connections are made using the M4508 and M4509 RJ45 connectors (see Figure
77 - Detail A).

RL
1
6

HOUSEKEEPING
OUT
13
1
IN
25
14
M4502

5
9
M1
RA

AUX CHANNELS

STUPA STUPB

SHELF ID

13

15

15

25

14

M4503

M4504

M4508 M4509

M4507

Figure 77 STEP-UP connections

2-56

Alcatel-Lucent - Proprietary
See notice on first page.

8DG09019HAAATQZZA
June 2009

STEP-UP cable routing

For these connections use the cable code 8DG90080AAAA (see Figure 78).

Connection table
Pair

Wire
White/Blue
Blue
White/Orange
Orange
White/Green
Green
White/Brown
Brown
Shielded cable braid

M1
1
5
2
6
3
7
4
8
Case

PinOut:
# Pin
1
2
3
4
5
6
7
8

Signal

Description

EC_STUPX_EECK
EC_STUPX_EECS
EC_STUPX_EEDO
STUPX_EC_EEDI
STUPX_EC_INTAL
STUPX_EC_EXAL
EC_STUPX_EEGND
EC_STUPX_EEVCC
GND

Clock signal from Equico


Chip select from Equico
Data signal from Step-Up
Data signal from Equico
Step-Up internal alarm
Step-Up external alarm
0V power supply
Positive power supply
Electrical ground - Case

X = Can be A or B for STEP UPA and STEP UP B


Figure 78 STEP-UP cable connections

8DG09019HAAATQZZA
June 2009

Alcatel-Lucent - Proprietary
See notice on first page.

2-57

Two cables have to be used to match connectors M4508 and M4509. After joining these
two cables to the connectors; the cables have to be laid out along the right side of the rack
(see Figure 79), and then, connected to the M1-M6 connectors placed on the GENTRU
unit.

To GENTRU

Figure 79 STEP-UP alarm cable

2-58

Alcatel-Lucent - Proprietary
See notice on first page.

8DG09019HAAATQZZA
June 2009

In the installation kit (code 8DG08845AA), two RJ45 connectors (code 1AB074610008)
are available, one for each STEP-UP, to perform these connections.
The connections on the GENTRU side are described in Error! Reference source not
found..

Position number reference


front side view

M1M2M3M4M5 and M6 STEP-UP alarms


Wire

Pins

WHITE/BLU
WHITE/ORANGE
WHITE/GREEN
WHITE/BROWN
BLU
ORANGE
GREEN
BROWN

1
2
3
4
5
6
7
8
9 & 10

Signals
EECKX (CLOCK)
EECSX (CHIP SELECT)
EED0X (DATA OUTPUT)
EEDIX (DATA INPUT)
INTALX
EXALX
EEGND
EEVCC
GNDM

Figure 80 STEP-UP GENTRU cable connections

8DG09019HAAATQZZA
June 2009

Alcatel-Lucent - Proprietary
See notice on first page.

2-59

Auxiliary channel connection


Description

The connections have to be executed through the 25-pins D-sub connector M4507.

RL
1

HOUSEKEEPING
13
1
OUT
IN
25
14
M4502

9
M1
RA

STUPA STUPB

SHELF ID

AUX CHANNELS

13

15

15

25

14

M4503

M4504

M4507

M4508 M4509

Figure 81 Auxiliary channel connections

AUX channel cable route

In the installation kit (code 8DG08845AA) there is a 25-pins connector (code


1AB003110023) with its shell (code 1AB006030064) to perform this connection. The
recommended cable is the one code 1AC014910012.
This port is suitable for the connections only to shielded intra-building cabling grounded
at both ends.
The cable has to be laid out along the right side of the rack.

2-60

Alcatel-Lucent - Proprietary
See notice on first page.

8DG09019HAAATQZZA
June 2009

The connections are described in Table 10.

Table 10 Auxiliary pin out


# Pin

Signal

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27

V11_IN1_P
V11_IN1_N
V11_OUT1_P
V11_OUT1_N
V11_CKOUT1_P
V11_CKOUT1_N
RS232_OUT1
RS232_IN1
D64_OUT1_P
D64_OUT1_N
D64_IN1_P
D64_IN1_N
GND
V11_IN2_P
V11_IN2_N
V11_OUT2_P
V11_OUT2_N
V11_CKOUT2_P
V11_CKOUT2_N
RS232_OUT2
RS232_IN2
D64_OUT2_P
D64_OUT2_N
D64_IN2_P
D64_IN2_N
GND
GND
V11
64 Kb/s G.703
RS232

8DG09019HAAATQZZA
June 2009

Description
V11 channel # 1; data signal input
V11 channel # 1; data signal output
V11 channel # 1; clock signal output

wire P
wire N
wire P
wire N
wire P
wire N

RS232 channel # 1; data signal output


RS232 channel # 1; data signal input
64 Kb/s channel # 1; data signal output
64 Kb/s channel # 1; data signal input

wire P
wire N
wire P
wire N

Electrical ground
V11 channel # 2; data signal input
V11 channel # 2; data signal output
V11 channel # 2; clock signal output

wire P
wire N
wire P
wire N
wire P
wire N

RS232 channel # 2; data signal output


RS232 channel # 2; data signal input
64 Kb/s channel # 2; data signal output
64 Kb/s channel # 2; data signal input

wire P
wire N
wire P
wire N

Electrical ground - Case


Electrical ground - Case
Pair 100 ohm
Pair 120 ohm
50 ohm

Alcatel-Lucent - Proprietary
See notice on first page.

2-61

Electrical cables routing


Description

In the picture below, points A, B, C and D show the output of the electrical cables used in
the TSS-320 subrack.
Point A --> max 9 cables (diameter < 6mm)
Point B --> max 1 cable (diameter < 6mm)
Point C --> max 1 cable (diameter < 6mm)
Point D --> max 9 cables (diameter < 6mm)
B

Figure 82 Electrical cables routing

The connections to the electrical SFP must be made with cable (code 1AC016760003)
and the connector RJ45 (code 1AB074610008).
These ports are suitable for the connections only to shielded intra-building cabling
grounded at both ends.
2-62

Alcatel-Lucent - Proprietary
See notice on first page.

8DG09019HAAATQZZA
June 2009

Fiber routing
Description

The picture below shown the fiber routing related to the TSS-320 system.

Figure 83 Fiber routing

8DG09019HAAATQZZA
June 2009

Alcatel-Lucent - Proprietary
See notice on first page.

2-63

Alcatel-Lucent 1850 TSS-160 boards installation and electrical


connections
Description

All the units pluggable in Alcatel Lucent 1850 TSS-160 equipment, are described in this
chapter.
The following paragraphs shows the electrical connections points are reported for every
units.
Contents

This section contains four kinds of units: common units, data units, SDH units, and
WDM units. They are described in the sections listed below:

2-64

Alcatel-Lucent 1850 TSS-160 connection points - common units

2-65

Alcatel-Lucent 1850TSS-160 connection points - SDH units

2-67

Alcatel-Lucent 1850 TSS-160 connection points DATA units

2-70

Alcatel-Lucent 1850 TSS-160 connection points Optical Amplifier units

2-73

Alcatel-Lucent 1850 TSS-160 connection points DWDM units

2-74

Alcatel-Lucent - Proprietary
See notice on first page.

8DG09019HAAATQZZA
June 2009

Alcatel-Lucent 1850 TSS-160 connection points - common


units
Note
18

42/43

PSF320
1

Tbus

39

EC320

20

19

36

18

35

17

34

16

33

15

32

14

31

13

30

12

29

41
FAN320

11

MT160

10

MT160

ACRONYM FAN320
SLOTS 40,41

10

11

SLOTS 37,39
18
50
TS
S16
0

AIR BAFFLE

ACRONYM PSF320

PSF320

EC320

1850TSS-160

37
40
FAN320

ACRONYM EC320
SLOTS 1, 20

12

13

14

ACRONYM MT160N, MT160LO


SLOTS 10,11

Note: Sett the position FF on rotating switches for Not installed shelf identification.

8DG09019HAAATQZZA
June 2009

Alcatel-Lucent - Proprietary
See notice on first page.

2-65

Extraction tool and SFP plug-out tool


(See Figure 131 and Figure 132)

16
17
15

21

22

Figure 84 Connection points for the installation of Alcatel-Lucent 1850 TSS-160 common units

2-66

Alcatel-Lucent - Proprietary
See notice on first page.

8DG09019HAAATQZZA
June 2009

Alcatel-Lucent 1850TSS-160 connection points - SDH units


NOTE
PSF320

42/43

39

Tbus

EC320

20

19

36

18

35

17

34

16

33

15

32

14

31

13

30

12
41
FAN320

PSF320

EC320

18
50
TS
S16
0

1850TSS-160

37
40
FAN320

29
11

MT 160

10

MT 160

AIR BAF FLE

1POTU2, Slot 12 to 19, 29 to 36

8PSO, Slot 12 to 19, 29 to 36

10xANY, Slot 12 to 19, 29 to 36

4P2G5SO, Slot 12 to 19, 29 to 36

LOA10G, Slot 33, 35, 36

1P10GSO, Slot 12 to 19, 29 to 36

Figure 85 Connection points for installation of Alcatel-Lucent 1850 TSS-160


SDH units

Note 1: For the installation of these boards in the sub-rack, use the half-slot adapter.

8DG09019HAAATQZZA
June 2009

Alcatel-Lucent - Proprietary
See notice on first page.

2-67

Note 2: The table below shows the relationship between the boards and modules.
Board
8PSO/10xANY
4P2G5SO/10xANY
4P2G5SO/10xANY
4P2G5SO/10xANY
4P2G5SO/10xANY
4P2G5SO/10xANY
4P2G5SO/10xANY
4P2G5SO/10xANY
8PSO/10xANY
8PSO/10xANY
4P2G5SO/10xANY
4P2G5SO/10xANY
4P2G5SO/10xANY
4P2G5SO/10xANY
4P2G5SO/10xANY
8PSO/10xANY
8PSO/10xANY
1P10GSO
8PSO/10xANY
4P2G5SO/10xANY
8PSO/10xANY
4P2G5SO/10xANY
4P2G5SO/10xANY
4P2G5SO/10xANY
4P2G5SO/10xANY
4P2G5SO/10xANY
4P2G5SO/10xANY
4P2G5SO/10xANY
4P2G5SO/10xANY
4P2G5SO/10xANY
1P10GSO
8PSO/10xANY
1P10GSO
1P10GSO
1P10GSO
1P10GSO
1P10GSO
1P10GSO
1P10GSO/10xANY
1P10GSO
1P10GSO
1P10GSO
2-68

Module code
1AB196360006
1AB196350028
1AB196350029
1AB196350030
1AB196350031
1AB196350032
1AB196350033
1AB196370013
1AB196360005
1AB196360007
1AB196370005
1AB196370006
1AB196370007
1AB196370008
1AB196370009
1AB196360004
1AB194670007
1AB356630041
1AB194670004
1AB196350027
1AB194670006
1AB196350026
1AB196340009
1AB196340010
1AB196340011
1AB196340012
1AB196340013
1AB196340014
1AB196340015
1AB196340016
1AB356630039
1AB194670005
1AB356630023
1AB356630034
1AB356630031
1AB214540001
1AB217280001
1AB356630040
1AB253330001
1AB356630024
1AB356630025
1AB356630026

Module description
OPTO TRX SFP L-4.1 DDM -40/+85
CWDM 1510NM APD SFP DDM
CWDM 1530NM APD SFP DDM
CWDM 1550NM APD SFP DDM
CWDM 1570NM APD SFP DDM
CWDM 1590NM APD SFP DDM
CWDM 1610NM APD SFP DDM
OPTO TRX SFP I-16.1 DDM -40/+85
OPTO TRX SFP S-4.1 DDM -40/+85
OPTO TRX SFP L-4.2 DDM -40/+85
OPTO TRX SFP I-16.1 DDM
OPTO TRX SFP S-16.1 DDM -5/+85
OPTO TRX SFP S-16.1 ANYRATE DDM
OPTO TRX SFP L-16.1 DDM -5/+80
OPTO TRX SFP L-16.2 DDM -5/+80
OPTO TRX SFP S-4.1 DDM
OPTO TRX SFP S-1.1 DDM -40/+85
OE-TRX XFP DWDM CH20
OPTO TRX SFP S-1.1 DDM
CWDM 1490NM APD SFP DDM
OPTO TRX SFP L-1.2 DDM -40/+85
CWDM 1470NM APD SFP DDM
CWDM 1470NM PIN SFP DDM
CWDM 1490NM PIN SFP DDM
CWDM 1510NM PIN SFP DDM
CWDM 1530NM PIN SFP DDM
CWDM 1550NM PIN SFP DDM
CWDM 1570NM PIN SFP DDM
CWDM 1590NM PIN SFP DDM
CWDM 1610NM PIN SFP DDM
OE-TRX XFP DWDM CH22
OPTO TRX SFP L-1.1 DDM -40/+85
OE-TRX XFP DWDM CH38
OE-TRX XFP DWDM CH27
OE-TRX XFP DWDM CH30
XFP I-64.1/10GBE BASE L
XFP S64-2B/10GBE BASE E
OE-TRX XFP DWDM CH21
XFP-E P1L1-2D2
OE-TRX XFP DWDM CH37
OE-TRX XFP DWDM CH36
OE-TRX XFP DWDM CH35
Alcatel-Lucent - Proprietary
See notice on first page.

SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
8DG09019HAAATQZZA
June 2009

Board
1P10GSO
1P10GSO
1P10GSO
1P10GSO
1P10GSO
1P10GSO
1P10GSO
1P10GSO
1P10GSO
1P10GSO
1P10GSO
1P10GSO
1P10GSO
1P10GSO
1P10GSO
1P10GSO
1P10GSO
10xANY

Module code
1AB356630027
1AB356630028
1AB356630029
1AB217280002
1AB356630036
1AB356630030
1AB356630038
1AB356630033
1AB356630035
1AB378370001
1AB378370002
1AB378370003
1AB378370004
1AB378370005
1AB378370006
1AB378370007
1AB378370008
1AB357990001

Module description
OE-TRX XFP DWDM CH34
OE-TRX XFP DWDM CH33
OE-TRX XFP DWDM CH32
XFP P1L1-2D2
OE-TRX XFP DWDM CH25
OE-TRX XFP DWDM CH31
OE-TRX XFP DWDM CH23
OE-TRX XFP DWDM CH28
OE-TRX XFP DWDM CH26
TRX XFP CWDM-LH CH47
TRX XFP CWDM-LH CH49
TRX XFP CWDM-LH CH51
TRX XFP CWDM-LH CH53
TRX XFP CWDM-LH CH55
TRX XFP CWDM-LH CH57
TRX XFP CWDM-LH CH59
TRX XFP CWDM-LH CH61
TRX SFP 100B FX DET

SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES

Yellow denotes the modules that need adapter code 3AL91721AA in order to be assembled in the
board.

8DG09019HAAATQZZA
June 2009

Alcatel-Lucent - Proprietary
See notice on first page.

2-69

Alcatel-Lucent 1850 TSS-160 connection points DATA units


NOTE
PSF320
1

42/43

Tbus

39

EC320

20

19

36

18

35

17

34

16

33

15

32

14

31

13

30

12

PSF320

EC320

18
50
TS
S16
0

1850TSS-160

37
40
FAN320

29

41
FAN320

11

MT160

10

MT160

AIR BAFFLE

PP1GE, Slot 12 to 19
24

25

24

25

PP10GE, Slot 12 to 19

PP1GESY, Slot 12 to 19
PP10GESY, Slot 12 to 19

24

25

PP10MS, Slot 12 to 19
Boards dimension: full slot
The access points are reported on Table 1 on page 2-23.
Figure 86 Connection points for installation of Alcatel-Lucent 1850 TSS-160
Data units

2-70

Alcatel-Lucent - Proprietary
See notice on first page.

8DG09019HAAATQZZA
June 2009

Note: In the following picture, the numbering of the SFP modules that can be plugged in
the PP10GE and PP10GESY circuit packs is shown.
PP10GE
1

10
PP10GESY

The table below shows the relationship between the boards and modules
Board
PP1GE/PP1GESY
PP1GE/PP1GESY
PP1GE/PP1GESY
PP1GE/PP1GESY
PP1GE/PP1GESY
PP1GE/PP1GESY
PP10GE/PP10GESY
PP10GE/PP10GESY
PP10GE/PP10GESY
PP1GE/PP1GESY
PP1GE/PP1GESY
PP1GE/PP1GESY
PP1GE/PP1GESY
PP1GE/PP1GESY
PP1GE/PP1GESY
PP1GE/PP1GESY
PP1GE/PP1GESY
PP1GE/PP1GESY
PP1GE/PP1GESY
PP1GE/PP1GESY
PP1GE/PP1GESY
PP1GE/PP1GESY
PP1GE/PP1GESY
PP1GE/PP1GESY
PP1GE/PP1GESY
PP1GE/PP1GESY
PP1GE/PP1GESY
PP10GE/PP10GESY
PP10GE/PP10GESY
PP10GE/PP10GESY
PP10GE/PP10GESY
PP10GE/PP10GESY
PP10GE/PP10GESY
PP10GE/PP10GESY
8DG09019HAAATQZZA
June 2009

Module code
1AB357990001
1AB187280031
1AB187280033
1AB187280040
1AB187280042
1AB187280045
1AB214540001
1AB214540002
1AB217280001
1AB359780001
1AB196350026
1AB196350027
1AB196350028
1AB196350029
1AB196350030
1AB196350031
1AB196350032
1AB196350033
1AB359780001
1AB196340009
1AB196340010
1AB196340011
1AB196340012
1AB196340013
1AB196340014
1AB196340015
1AB196340016
1AB356630023
1AB356630024
1AB356630025
1AB356630026
1AB356630027
1AB356630028
1AB356630029

Module description
OE-TRX SFP 100B FX
OPTO TRX SFP 1GBE LX DDM
OPTO TRX SFP 1GBE SX DDM
OPTO TRX SFP 1.25GBE LX DDM -40/+85
OPTO TRX SFP 1GBE ZX DDM
OPTO TRX SFP 1.25GBE SX DDM -40/+85
XFP I-64.1/10GBE BASE L
XFP 10GBE BASE S (UP TO 10.3 GBS)
XFP S64-2B/10GBE BASE E
EL TRX SFP 1000BASE-T
SFP CWDM APD CH47 DDM
SFP CWDM APD CH49 DDM
SFP CWDM APD CH51 DDM
SFP CWDM APD CH53 DDM
SFP CWDM APD CH55 DDM
SFP CWDM APD CH57 DDM
SFP CWDM APD CH59 DDM
SFP CWDM APD CH61 DDM
TRX SFP 1000B Copper NB
SFP CWDM PIN CH47 DDM
SFP CWDM PIN CH49 DDM
SFP CWDM PIN CH51 DDM
SFP CWDM PIN CH53 DDM
SFP CWDM PIN CH55 DDM
SFP CWDM PIN CH57 DDM
SFP CWDM PIN CH59 DDM
SFP CWDM PIN CH61 DDM
TRX XFP 10G DWDM Ch38
TRX XFP 10G DWDM Ch37
TRX XFP 10G DWDM Ch36
TRX XFP 10G DWDM Ch35
TRX XFP 10G DWDM Ch34
TRX XFP 10G DWDM Ch33
TRX XFP 10G DWDM Ch32
Alcatel-Lucent - Proprietary
See notice on first page.

SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
2-71

Board
PP10GE/PP10GESY
PP10GE/PP10GESY
PP10GE/PP10GESY
PP10GE/PP10GESY
PP10GE/PP10GESY
PP10GE/PP10GESY
PP10GE/PP10GESY
PP10GE/PP10GESY
PP10GE/PP10GESY
PP10GE/PP10GESY
PP10GE/PP10GESY
PP10GE/PP10GESY
PP10GE/PP10GESY
PP10GE/PP10GESY
PP10GE/PP10GESY
PP10GE/PP10GESY
PP10GE/PP10GESY
PP10GE/PP10GESY

Module code
1AB356630030
1AB356630031
1AB356630032
1AB356630033
1AB356630034
1AB356630035
1AB356630036
1AB356630037
1AB356630038
1AB356630039
1AB378370001
1AB378370002
1AB378370003
1AB378370004
1AB378370005
1AB378370006
1AB378370007
1AB378370008

Module description
TRX XFP 10G DWDM Ch31
TRX XFP 10G DWDM Ch30
TRX XFP 10G DWDM Ch29
TRX XFP 10G DWDM Ch28
TRX XFP 10G DWDM Ch27
TRX XFP 10G DWDM Ch26
TRX XFP 10G DWDM Ch25
TRX XFP 10G DWDM Ch24
TRX XFP 10G DWDM Ch23
TRX XFP 10G DWDM Ch22
TRX XFP CWDM-LH CH47
TRX XFP CWDM-LH CH49
TRX XFP CWDM-LH CH51
TRX XFP CWDM-LH CH53
TRX XFP CWDM-LH CH55
TRX XFP CWDM-LH CH57
TRX XFP CWDM-LH CH59
TRX XFP CWDM-LH CH61

SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES
SFP/XFP MODULES

Yellow denotes the modules that need the adapter (code 3AL91721AA) to be assembled in the
board.
NB : for these connection to use the cable code 1AC016760003 and the RJ45 connector code
1AB074610008. For the cable assembly see 2-41

2-72

Alcatel-Lucent - Proprietary
See notice on first page.

8DG09019HAAATQZZA
June 2009

Alcatel-Lucent 1850 TSS-160 connection points Optical


Amplifier units
PSF320
1

42/43

Tbus

EC320

PSF320

EC320

19

36

18

35

17

34

16

33

15

32

14

31

13

30

12
41
FAN320

39
20

18
50
TS
S16
0

1850TSS-160

37
40
FAN320

29
11

MT 160

10

MT 160

AIR BAFF LE

LOFA1111, Slot 12 to 15, board dimension: full slot

BST10G, Slot 12 to 19, 29 to 36, board dimension: half slot

PR10G, Slot 12 to 19, 29 to 36, board dimension: half slot

Figure 87. Connection points for installation of Alcatel-Lucent 1850 TSS-160


OPTICAL AMPLIFIER UNITS

8DG09019HAAATQZZA
June 2009

Alcatel-Lucent - Proprietary
See notice on first page.

2-73

Alcatel-Lucent 1850 TSS-160 connection points DWDM units


42/43

PSF 320
1

T bus

EC320

PSF320

EC320

19

36

18

35

17

34

16

33

15

32

14

31

13

30

12
41
FAN320

39
20

18
50
TS
S16
0

1850TSS-160

37
40
FAN320

29
11

MT160

10

MT160

AIR BAFFLE

OMDX8100-L1_G, Slot 12 to 15, boards dimension: full slot

OMDX8100-L2_G, Slot 12 to 15, boards dimension: full


l t
NB1

NB2

DWLA10X, Slot 12 to 19, 29 to 36, boards dimension: half slot

Figure 88. Connection points for installation of Alcatel-Lucent 1850 TSS-160


DWDM UNITS

2-74

Alcatel-Lucent - Proprietary
See notice on first page.

8DG09019HAAATQZZA
June 2009

N.B.1 In this cavity (WDM/Line side), the following XFPs can be plugged
Board
DWLA10X
DWLA10X
DWLA10X
DWLA10X
DWLA10X
DWLA10X
DWLA10X
DWLA10X
DWLA10X
DWLA10X
DWLA10X
DWLA10X
DWLA10X
DWLA10X
DWLA10X
DWLA10X
DWLA10X
DWLA10X
DWLA10X

Module code
1AB356630023
1AB356630024
1AB356630025
1AB356630026
1AB356630027
1AB356630028
1AB356630029
1AB356630030
1AB356630031
1AB356630032
1AB356630033
1AB356630034
1AB356630035
1AB356630036
1AB356630037
1AB356630038
1AB356630039
1AB356630040
1AB356630041

Module description
TRX XFP 10G DWDM Ch38
SFP/XFP MODULES
TRX XFP 10G DWDM Ch37
SFP/XFP MODULES
TRX XFP 10G DWDM Ch36
SFP/XFP MODULES
TRX XFP 10G DWDM Ch35
SFP/XFP MODULES
TRX XFP 10G DWDM Ch34
SFP/XFP MODULES
TRX XFP 10G DWDM Ch33
SFP/XFP MODULES
TRX XFP 10G DWDM Ch32
SFP/XFP MODULES
TRX XFP 10G DWDM Ch31
SFP/XFP MODULES
TRX XFP 10G DWDM Ch30
SFP/XFP MODULES
TRX XFP 10G DWDM Ch29
SFP/XFP MODULES
TRX XFP 10G DWDM Ch28
SFP/XFP MODULES
TRX XFP 10G DWDM Ch27
SFP/XFP MODULES
TRX XFP 10G DWDM Ch26
SFP/XFP MODULES
TRX XFP 10G DWDM Ch25
SFP/XFP MODULES
TRX XFP 10G DWDM Ch24
SFP/XFP MODULES
TRX XFP 10G DWDM Ch23
SFP/XFP MODULES
TRX XFP 10G DWDM Ch22
SFP/XFP MODULES
TRX XFP 10G DWDM Ch21
SFP/XFP MODULES
TRX XFP 10G DWDM Ch20
SFP/XFP MODULES

N.B.2 In this cavity (client side), the following XFPs can be plugged
Board
DWLA10X
DWLA10X
DWLA10X

Module code
1AB214540001
1AB214540002
1AB217280001

Module description
TRX XFP I-64.1
SFP/XFP MODULES
TRX XFP 10GBASE-S
SFP/XFP MODULES
TRX XFP S-64.2
SFP/XFP MODULES

Yellow denotes the modules that need adapter code 3AL91721AA in order to be assembled in the board.

8DG09019HAAATQZZA
June 2009

Alcatel-Lucent - Proprietary
See notice on first page.

2-75

Table 11 Numbering, functions, and paragraphs referred to the TSS-160 connection


points

2-76

ACCESS
POINT

SLOT

FUNCTION

FROM/TO

37, 39

Input Battery (PSF320)

GENTRU/
MANGTRU

37, 39

Synchronization connection

DDF

1, 20

10/100 ETH Debug RJ45 connector

Factory use only

1, 20

Local Craft Terminal connector


(RS232 F interface)

CT

1, 20

RS232 on uUSB debug connector

Factory use only

1, 20

Local Craft Terminal connector mUSB


connector (F interface)

CT

1, 20

USB interface for external memory device

PC

10, 11

uUSB Debug connector

Factory use only

10

10, 11

RJ45 Debug connector

Factory use only

11

10, 11

10/100 Mbit/s Q3 interface

DDF

12

10, 11

10/100 Mbit/s redundant Q3 interface

DDF

13-14

10, 11

ETH/FETH/GETH interface

Drop shelf

15

Back Panel

Rack Lamp

GENTRU/
MANGTRU

16

Back Panel

Housekeeping

DDF

17

Back Panel

Rack Alarm

DDF

18

Back Panel

Shelf ID

Termination

21

Back Panel

Step up A Alarm

GENTRU/
MANGTRU

22

Back Panel

Step up B Alarm

GENTRU/
MANGTRU

24

2-9
12-19

RJ45 connector

Factory use only

25

2-9
12-19

uUSB RS232 connector

Factory use only

Alcatel-Lucent - Proprietary
See notice on first page.

8DG09019HAAATQZZA
June 2009

Power supply & synchronization


Description

The following paragraphs describe the power connections between Alcatel-Lucent 1850
TSS-160 and GENTRU.
Contents

This chapter contains the following:


GENTRU Power supply connection

2-78

GENTRU power connection

2-80

MANGTRU power supply connection

2-84

Synchronization connections

2-90

8DG09019HAAATQZZA
June 2009

Alcatel-Lucent - Proprietary
See notice on first page.

2-77

GENTRU Power supply connection


Description

Note: Before connecting the power supply, check that the related circuit breaker is open.
This section describes the power supply connection on the PSF320 board which is
inserted into slot 37 and slot 39 of the sub-rack.
Use the cable code 8DG87298AAAA and inserted in the kit code 8DG87321AAAA.

PSF320
PSF320 side

GENTRU side

Slot 37, 39

Note 1: Isolate with tube P/N 1AC000050090.


Note 2: Thermoshrinking tube P/N 1AC000570097

Figure 89 PSF320 side

2-78

Alcatel-Lucent - Proprietary
See notice on first page.

8DG09019HAAATQZZA
June 2009

Power cable routing

Connect the cable to the 5 pins subD connector placed on the front plate of PSF320.

The cables must be routed over the sub-rack and fixed with the fasten strips as shown
in the following figure.
Left power cable

LEFT POWER CABLE ROUTE

Right power cable

RIGHT POWER CABLE ROUTE

Figure 90 Electrical cables route

Both cables must be housed into the racks right duct, and then fastened to the related
side holder using waxed thread.

Connect the cables to subD connectors of the STEP-UP unit (A for slot 37, B for slot
39). See the next section, GENTRU power connection.

8DG09019HAAATQZZA
June 2009

Alcatel-Lucent - Proprietary
See notice on first page.

2-79

GENTRU power connection


Description

Assemble the EMI FILTER and GENTRU on the rack (using the relative installation kits codes
8DG08847AA and 8DG08216AA). Connect the EMI FILTER to the GENTRU as shown in
Figure 46 and described in the Mechanical installation of the EMI-FILTER and GENTRU
section. Set the socket connectors (that are parts of the GENTRU installation kit code
8DG08216AA) on the GENTRU as indicated in the Figure 47.
Qty. 3
screws M3
EMI
FILTER

GENTRU
Qty. 5
screws M6x12

Figure 91 EMI FILTER and GENTRU connection

GENTRU socket setting configurations

M29

SLOTS 1
2-80

M56

M65

Alcatel-Lucent - Proprietary
See notice on first page.

7
8DG09019HAAATQZZA
June 2009

Here below the possible configurations of the GENTRU sockets


2)

L1,L2 and L3 are three different lines

M29
2)

M56

M65

L1 and L2 in parallel
3AL92210AAAA

M29
3)

M56

L1 and L3 in parallel

M29
4)

M65

M56

3AL92207AAAA

M65

L1, L2 and L3 in parallel

M29

M56

M65

Figure 92 GENTRU socket setting


Note: for 2), 3) and 4) the max power consumption of the line L1 must be 3,5 KW

Note: When the setting configurations are finished cover the sockets with the plastic
protection code 8DG07731AAAA.

8DG09019HAAATQZZA
June 2009

Alcatel-Lucent - Proprietary
See notice on first page.

2-81

Insert the STEP-UP A and B in slots 2 and 3 into the GENTRU. Connect the STEP-UP
cables and the Rack Lamp cable on the GENTRU .
For the STEP-UP connection, all the materials (Shell code 8DG08118AAAA - qty. 1,
SubD Female connector 5 wires - code 1AB040970018 - qty.1, and Contacts Crimp
3.8mm - code 1AB044280028 qty. 3) are included in the BOM of the power cable code
8DG87298AAAA. The power supply cable must be connected to subD connectors placed
on the STEP-UP.
Figure 93 shows the power supply connector pins, and Table 12 describes the related
function.
A1

A2

A3

A4

A5

Figure 93 STEP-UP output power connectors

Table 12 STEP-UP output power connectors

2-82

PINS

SIGNALS

A1

Step-up positive output

A2

Step-up positive output NOT USED

A3

GND

A4

Step-up negative output NOT USED

A5

Step-up negative output

Alcatel-Lucent - Proprietary
See notice on first page.

8DG09019HAAATQZZA
June 2009

Crimp the 90 lug inserted in the GENTRU installation kit (code 8DG08216AA) on
the 25mm cables of line A, line B, and GND from Central station, and connect them
to the EMI FILTER (as shown in Figure 94).

Table 13 Suggested cable


Code

Description

Cable color

1AC 00730 0055

Power cable 1x25 mm2

Black

1AC 03220 0001

Power cable 1x25 mm2

Red

1AC 03219 0001

Power cable 1x25 mm2

Blue

1AC 00780 0057

Power cable 1x25 mm2

Yellow/Green

Line A

Lugs

Line B

GND

Cover

Figure 94 Connection of Central station line cables to EMI FILTER


Note: The section of the cable must be calculated, in the ETSI range temperature, in
accordance with Alcatel-Lucent specification code 1AC001060002 DSZZA.

8DG09019HAAATQZZA
June 2009

Alcatel-Lucent - Proprietary
See notice on first page.

2-83

MANGTRU power supply connection


Description

Note: Before connecting the power supply, check that the related circuit breaker is open.
This section describes the power supply connection on the PSF320 board which is
inserted into slot 37 and slot 39 of the sub-rack.
The cable to use is 8DG87298AAAA and inserted in the kit code 8DG87321AAAA.
The power cable is supplied with the 3 female contacts. In order to connect this cable to
the MANGTU, it is necessary to change the central contact on the yellow/green wire with
the male contact code 1AB044280022.

PSF320
PSF320 side

MANGTRU side

1
Male

Female

A2
A3

Slot 37, 39
Note 1: Isolate with tube P/N 1AC000050090.
Note 2: Thermo shrink tube P/N 1AC000570097
Note 3 Assembly the subd 3 poles connector and shell. All the needed materials (shell
code 1AB006030063, subD connector code 1AB040970009 and the contacts code
1AB044280022 qty 1 and code 1AB044280028 qty 2) are included in the power cable
code 8DG87298AAAA
Figure 95 PSF320 side

2-84

Alcatel-Lucent - Proprietary
See notice on first page.

8DG09019HAAATQZZA
June 2009

Power cable routing

Connect the cable to the subD connector placed on the front plate of PSF320.

The cables must be routed over the sub-rack and fixed with the fasten strips as shown
in the following figure.
Left power cable

LEFT POWER CABLE ROUTE

Right power cble

RIGHT POWER CABLE ROUTE

Figure 96 Electrical cables route

Both cables must be housed into the racks right duct, and then fastened to the related
side holder using waxed thread

Connect the cables to subD connectors M10-M11 of the MANGTRU. See the next
section, MANGTRU power connection

8DG09019HAAATQZZA
June 2009

Alcatel-Lucent - Proprietary
See notice on first page.

2-85

MANGTRU power connection


General rules for power supply cables coming from main distribution to
MANGTRU.

Figure 97 Configuration of the NGTRU with Step-up (N.B.)


N.B. In order to power one 1850 TSS-320 sub-rack, two STEP-UP converter must be
inserted into the MANGTRU.

2-86

Alcatel-Lucent - Proprietary
See notice on first page.

8DG09019HAAATQZZA
June 2009

M56

M29

M65

Figure 98 Details MANGTRU


Here below the possible configurations of the MA-NGTRU sockets
1)

M29
2)

M29

8DG09019HAAATQZZA
June 2009

L1,L2 and L3 are three different lines

M56

M65

L1 and L2 in parallel

M56

M65

Alcatel-Lucent - Proprietary
See notice on first page.

2-87

3)

L1 and L3 in parallel

3AL92210AAAA
M29
4)

M56

M65

L1, L2 and L3 in parallel


3AL92207AAAA

M29

M56

M65
3AL92209AAAA

Figure 99 MANGTRU socket setting

Note: for 2), 3) and 4) the max power consumption of the line L1 must be 2 KW

Note: When the setting configurations are finished cover the sockets with the plastic
protection code 8DG07731AAAA.

2-88

Alcatel-Lucent - Proprietary
See notice on first page.

8DG09019HAAATQZZA
June 2009

The Figure 100 shows the power supply connectors pins and Table 14 the related
function.

Figure 100 M10-M11-M12-M13-M14 and M15 Output Power Connectors


Table 14 M10, M11, M12, M13, M14 and M15 Output Power Connectors
PINS
1
2
3

SIGNALS
Step-up positive output
GNDM
Step-up bypass negative output

The connections correlation between the Power supply units (PSF) inserted into the
subrack 1850 TSS-160 and subD high power connector of the MANGTRU is described
in the following table.
Table 15 Power connection to the MANGTRU
Power Supply Unit (slot)

MANGTRU
Cable

Slot
37
39
37
39
37
39

Subrack (NB1)
1
1
2
2
3
3

SUB D connector
M10
M11
M12
M13
M14
M15

10

Note: Subrack N1 is the first subrack installed in the rack.

8DG09019HAAATQZZA
June 2009

Alcatel-Lucent - Proprietary
See notice on first page.

2-89

Synchronization connections
Description

These connections are made by the adapter code 8DG08739AAAA inserted into the 9-pin
SubD (2) connector placed on the front panel of the PSF320 board.

PSF320

Connector

COAX ADAPTER

Function

Output signal

Input signal

Cable
2

PSF320

A
2
B

Slot 37-39

Figure 101 PSF320 front plate connectors

The connections can be at 75 ohms (see 75-ohm synchronization coaxial cable) or at


120 ohms (see 120-ohm synchronization cable).

2-90

Alcatel-Lucent - Proprietary
See notice on first page.

8DG09019HAAATQZZA
June 2009

75-ohm synchronization coaxial cable

These connections are made with the cable 1AC001100013 equipped with 75-ohm
coaxial connector( code 1AB061220018).
These connectors are included in kit 8DG87321AAAA.
The following figures show the assembly instruction for the coaxial connector.

Remove the insulation after the sign.

Push "A" into the cable.

Push the inner conductor "B" into the dielectric (small square).

Push the cable end in connector "C".

crimp here

10 Push "A" in the connector and crimp (big hexagon).

Figure 102 Cable 75 Ohm synchronization instruction

8DG09019HAAATQZZA
June 2009

Alcatel-Lucent - Proprietary
See notice on first page.

2-91

120-ohm synchronization cable

For this type of connection, a cable like the one reported in Figure 54 on page 2-34 must
be build up in field.

1AC 00110 0013 Coax Cable


75 ohm 3.1 mm diam.

1AB 15834 0001 BALUN


1.0/2.3

Equipment
side

DDF
side

1AB 00979 0019 Female


Coax Conn 1.0/2.3

1AB 06122 0018 Male


Coax Conn 1.0/2.3 45

Shielded Twisted pair cable

Figure 103 120-ohm synchronization cable


For the connector 1AB061220018 instructions, see the description on page 2-33.
For the connectors BALUN Male and Female, see the assembly instructions for
following manufacturers: Siemens and ITT CANNON.

SIEMENS CONNECTOR:
See Figure 55 on page 2-35

Strip the cable. If no screen is available, then dimension 6 is not applicable and
dimension 13 becomes 11.

Unscrew the ferrule (5) and remove the insulator (3) and washer (4).

Push the ferrule (5) over the cable.

Push a washer (4) over the screen and bend the screen back.

Push the second washer over the cable up to stop.

Cut the projecting screen to a length of about 2 mm max.

Insert the wires into holes A (corresponding with coax center conductor) and B of the
insulator (3), and push the insulator up against the washer.

Spread the wires open and bend them over 180 laying into the cable duct.

Make sure that the end of the copper wires:


are laying parallel or bend toward the center of insulator
must not lay on to stop

2-92

Alcatel-Lucent - Proprietary
See notice on first page.

8DG09019HAAATQZZA
June 2009

Push the prepared cable onto the body (1) by lining up the flat side on the insulator
with the nose on the body.

Push on ferrule (5), screw on, and lightly tighten using wrench 8 mm.
(1)

(3)

(4)

(5)

(2)

Legenda:
1 - BODY
2 - IDC CONTACT
3 - INSULATOR
4 - WASHER
5 - FERRULE

13

6
2 mm max.

Figure 104 SIEMENS BALUN assembling instruction

8DG09019HAAATQZZA
June 2009

Alcatel-Lucent - Proprietary
See notice on first page.

2-93

ITT CANNON CONNECTOR:


See Figure 105 on page 2-94.

Thread the plastic outer sleeve and pierce block onto the stripped cable.

Lay the insulated wires and drain wire in the appropriate slots in the pierce block.
Trim excess wire flush with the underside of the flange.

Align the connector body with the plastic parts, place them in the jaws of the
termination tool, and close the tool to complete the assembly.
(1)

(2)

(3)

(4)

(5)

Legenda:
Signal

Screen
1 - BODY
2 - IDC CONTACT
3 - PIERCE BLOCK
4 - PLASTIC OUTER SLEEVE
5 - CABLE

Figure 105 ITT Cannon BALUN assembling instruction

2-94

Alcatel-Lucent - Proprietary
See notice on first page.

8DG09019HAAATQZZA
June 2009

Synchronization cable routing

This paragraph describes the correct installation route for the Synchronization cable.
Figure 106 on page 2-95 shows the correct cables route.

Synchronization cable routing.


PSF in slot 37.

Synchronization cable routing. PSF in slot 39.

Synchronization
cable routing.
PSF in slot 37.
Synch.
cable
routing.
PSF in
slot 39.

Figure 106 Synchronization cable route


8DG09019HAAATQZZA
June 2009

Alcatel-Lucent - Proprietary
See notice on first page.

2-95

EC320 unit connection


This paragraph describes all the electrical points available on the front panel of the EC
320 unit.

ECA

LEGEND
(1)

(2)

(3)
(4)
(5)
(6)

BOARD STATUS MULTICOLOR LED:


LED OFF: card inserted and not running
AMBER BLINK: fpga download
GREEN BLINK: sw boot/self test
GREEN: CARD provisioned and running
RED: card fail
RED BLINK: card miss-configured or card missmatch
EPS MULTICOLOR LED:
GREEN: eps configured - card active
AMBER: eps configured - card stand- by
AMBER LINK: eps configured but not available
OFF: eps not configured
RESET COMMAND KEY
10/100 ETH DEBUG RJ45 CONNECTOR - factory use only
GREEN LED ON: full duplex
GREEN LED OFF: half duplex
YELLOW LED ON: link/active (no activity)
YELLOW LED BLINK: link/active (with activity)
YELLOW LED OFF: no link
RS232 on mUSB DEBUG CONNECTOR factory use

(7)
only
(8)
LOCAL CRAFT TERMINAL mUSB CONNECTOR (F
interface)
(9)
LOCAL CRAFT TERMINAL CONNECTOR (RS232 F
interface)
(10)
USB INTERFACE for external memory device
(11)
ALARM CUT-OFF KEY
(12)
LAMP TEST KEY
(13)
RED LED - critical alarm
(14)
RED LED - major alarm
(15)
ORANGE LED - minor alarm
(16)
ORANGE LED - warning alarm
(17)
RED LED - attended alarm
(18)
ORANGE LED - abnormal condition

Slot 1, 20

Figure 107 EC320 front plate unit connectors

2-96

Alcatel-Lucent - Proprietary
See notice on first page.

8DG09019HAAATQZZA
June 2009

MATRIX unit connection


This section describes all the electrical points available on the front panel of the MT160N
/ MT320LO unit.
MT160N, MT160LO

LEGEND
(1)

EPS Multicolor LED:


GREEN: EPS configured - Card Active
AMBER: EPS configured - Card Stand-by
AMBER BLINK: EPS configured but not available
SWITCHED OFF: EPS not configured
(2)
BOARD STATUS Multicolor LED:
LED OFF: card inserted and not running
AMBER BLINK: fpga download
GREEN BLINK: sw boot/self test
GREEN: CARD provisioned and running
RED: card fail
RED BLINK: card miss-configured or card mismatch
(3)
Shelf Controller Restart Command Key
(4)
mUSB DEBUG connector - Factory use only
(5)
RJ45 DEBUG connector - Factory use only
(6) (9) (12)
GREEN LED ON: link/active (no activity)
GREEN LED BLINK: link/active (with activity)
GREEN LED OFF: no link
(7) (10) (13)
YELLOW LED ON: full duplex
YELLOW LED OFF: half duplex
YELLOW LED BLINKING: collision
(8)
10/100 Mbit/s Q3 interface
(11)
10/100 Mbit/s redundant Q3 interface
(14) (17) ETH/FETH/GETH interface for Drop Shelf
connection
(15) (18) Multicolor LED:
GREEN LED ON: 10/100 Mb/s link active (no activity)
GREEN LED BLINK: 10/100 Mb/s link active (with activity)
ORANGE LED ON: 1000 Mb/s link active (no activity)
ORANGE LED BLINK: 1000 Mb/s link active (with activity)
(16) (19)
YELLOW LED ON: full duplex
YELLOW LED OFF: half duplex
YELLOW LED BLINKING: collision

Slot 10, 11
Figure 108 Matrix front plate unit connectors

8DG09019HAAATQZZA
June 2009

Alcatel-Lucent - Proprietary
See notice on first page.

2-97

The LAN connections must be made with cable code 1AC016760003 and the connector
RJ45 ( code 1AB074610008) included in the installation kit (code 8DG87321AAAA).
The connector RJ45 assembling procedure is shown as follow:
The following instructions are to assemble the cable (code 1AC 01676 0003) with the
connector RJ45 (code 1AB074610008).
This port is suitable for the connections only to shielded intra-building cabling grounded
at both ends.

Assembly instructions
Slide the boot onto the cable (if needed).
Remove the outer jacket of the cable to the length shown in Figure 109. Take care not to
nick the shield or cut into any of the conductors.

Figure 109 Cable assembling cable instruction


Fold the cable shield (and the drain wire if present) back over the outer jacket as shown in
Figure 110. Then slide the shield onto the cable shield.
Take care that the shield remains on the cable shield.

Figure 110 Cable assembling instruction

2-98

Alcatel-Lucent - Proprietary
See notice on first page.

8DG09019HAAATQZZA
June 2009

Orientate the conductors in the desired sequence and trim off any excess length of the
conductors (refer to Figure 111).

Figure 111 Assembly cable instruction


Insert the cable into the plug as shown in Figure 112. Push the outer jacket towards
the plug. Slide the shield onto the plug.

Figure 112 Cable assembling instruction

8DG09019HAAATQZZA
June 2009

Alcatel-Lucent - Proprietary
See notice on first page.

2-99

Reduce the length of the shielded pairs (refer to Figure 113).

Figure 113 Assembly cable instruction

For separating a pair, remove the shield foil from this pair outside the outer jacket.
Orientate the pairs in the desired sequence.
Reduce the foil of the other pairs. For best results in low cross-talk, take care to keep
the foil as long as possible (refer to Figure 114). The most important pair is the one
between the separated conductors.

Figure 114 Cable assembling instruction

2-100

Alcatel-Lucent - Proprietary
See notice on first page.

8DG09019HAAATQZZA
June 2009

Orientate the conductors in the desired sequence and trim off any excess length of the
conductors. Insert the cable into the plug (refer to Figure 115).
Push the outer jacket towards the plug.
Slide the shield onto the plug.

Figure 115 Cable assembling instruction


Use the tools to crimp the strain relief, contacts, and ferrule.
For detailed information on the Molex application tools, see the Molex website or
refer to the catalogue.
Remove the protruding cable shield.
Slide the boot onto the cable, up to the dimension.
Solder the cable as reported on Table 16.

Table 16 Insertion wires table

PIN

1
2
3
4
5
6
7
8
8DG09019HAAATQZZA
June 2009

Cable

White/Green
Green
White/Orange
Blue
White/Blue
Orange
White/Brown
Brown

Function

Pair 3
Pair 3
Pair 2
Pair 1
Pair 1
Pair 2
Pair 4
Pair 4

TXP (OUT)
TXN (OUT)
RXP (IN)

RXN (IN)

Alcatel-Lucent - Proprietary
See notice on first page.

2-101

Management LAN cables routing

This section describes the correct installation route for the LAN cables connected to the
MT160N / MT320LO unit.

Figure 116 Management LAN cable

2-102

Alcatel-Lucent - Proprietary
See notice on first page.

8DG09019HAAATQZZA
June 2009

Electrical connections
Description

This paragraph describes all the electrical connections located on the upper side of the
Alcatel-Lucent 1850 TSS-160 equipment.
Contents

This chapter contains the following:


STEP-UP A/B cable

2-106

Rack lamp cable

2-107

Housekeeping cable pin-out

2-108

8DG09019HAAATQZZA
June 2009

Alcatel-Lucent - Proprietary
See notice on first page.

2-103

Electrical connection

Figure 117 shows the name and the positions of connectors.


Not used
Housekeeping

Remote Alarm
Sub D 15p Female connector

Sub D 15p Male connector

Sub D 25p Female connector

Rack Lamp
Sub D 9p Male
Connector

Step up Alarm
RJ45 connectors

Figure 117 Alcatel-Lucent 1850 TSS-160 top view

2-104

Alcatel-Lucent - Proprietary
See notice on first page.

8DG09019HAAATQZZA
June 2009

All of the electrical connections in the Alcatel-Lucent 1850 TSS-160 equipment are
described in Table 17.

Table 17 Electrical connections


INTERFACE

CABLE CODE

BACK
PANEL
BACK
PANEL

Alarm
STEP UP A/B

8DG90080AAAA

Note

1AB074610008

RJ45

Note

RL

8DG87347AAAA

Note

1AB074610008

RJ45

Note

1AB003110023

Sub D Connector
25 p Male

BACK
HOUSEKEEPING
PANEL

Q.TY NOTE

CONNECTOR
DESCRIPTION Q.TY NOTE
CODE

UNIT

Note
1AB006030189

Shel Connector

Note: See Installation kit 8DG87321AAAA.

8DG09019HAAATQZZA
June 2009

Alcatel-Lucent - Proprietary
See notice on first page.

2-105

STEP-UP A/B cable


STEP-UP alarm cable code 8DG90080AAAA.

Pin out Cable


Cable stripping detail

The following figure shows the STEP-UP cable route:

This port is suitable for the connections only to shielded intra-building cabling grounded
at both ends
2-106

Alcatel-Lucent - Proprietary
See notice on first page.

8DG09019HAAATQZZA
June 2009

Rack lamp cable


Rack lamp cable (code 8DG87347AAAA).
This port is suitable for the connections only to shielded intra-building cabling grounded
at both ends.

Pin out Cable


Cable stripping detail

The following figure shows the Rack lamp cable route:

8DG09019HAAATQZZA
June 2009

Alcatel-Lucent - Proprietary
See notice on first page.

2-107

Housekeeping cable pin-out


This port is suitable for the connections only to shielded intra-building cabling grounded
at both ends.
Table 18 Housekeeping connector pin-out

Pin-out:
# Pin
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27

Signal

Description

HK_OUTN_1
HK_OUTP_1

# 1 Output; N wire
# 1 Output; P wire

HK_OUTN_2
HK_OUTP_2

# 2 Output; N wire
# 2 Output; P wire

HK_OUTN_3
HK_OUTP_3

# 3 Output; N wire
# 3 Output; P wire

HK_OUTN_4
HK_OUTP_4

# 4 Output; N wire
# 4 Output; P wire

HK_IN1
HK_IN2
HK_IN3
HK_IN4
HK_IN5
HK_IN6
HK_IN7
HK_IN8

# 1 Input
# 2 Input
# 3 Input
# 4 Input
# 5 Input
# 6 Input
# 7 Input
# 8 Input

HK_REF

Voltage reference of input housekeeping

GND
GND

Electrical ground - Case


Electrical ground - Case

HK = Housekeeping

2-108

Alcatel-Lucent - Proprietary
See notice on first page.

8DG09019HAAATQZZA
June 2009

Electrical cable routing


Figure 118 shows the correct cables routing.

Housekeeping cable

Rack Lamp cable

Step Up Alarm
Cables

Figure 118 Electrical cables routing

8DG09019HAAATQZZA
June 2009

Alcatel-Lucent - Proprietary
See notice on first page.

2-109

Detail

Figure 119 Electrical cables routing

The picture above shows the output of the electrical cables used in the TSS-160 subrack.
Point A --> max 16 cables (diameter < 6mm)
The connections to the electrical SFP must be made with cable (code 1AC016760003)
and the connector RJ45 (code 1AB074610008).
These ports are suitable for the connections only to shielded intra-building cabling
grounded at both ends.

2-110

Alcatel-Lucent - Proprietary
See notice on first page.

8DG09019HAAATQZZA
June 2009

Fiber routing
Description

This section describes the fiber routing related to the TSS-160 system equipment
solutions.

8DG09019HAAATQZZA
June 2009

Alcatel-Lucent - Proprietary
See notice on first page.

2-111

Fiber conveyor installation


Description

The optical fibers outgoing from the subrack require the installation of a FIBER
CONVEYOR, as shown in the following figure.
M2,5
3AL94526AAAA
Qty. 2

8DG87273AAAA

M4x8
1AD008840021

8DG87288AAAA

8DG87275AAAA

8DG87272AAAA

Figure 120 Fiber conveyor

Figure 120 shows the FIBER CONVEYOR with the fibres at the bottom side of the rack.
For the case of the fibers at the top side of the rack, it is necessary for the inversion of the
two FIBER CONVEYORS mounting (code 8DG87275AAAA) on the left side and on the
right side (code 8DG87288AAAA).
The Alcatel-Lucent 1850 TSS-160 ETSI SHELF installation kit code 8DG87321AAAA
contains all these items.

2-112

Alcatel-Lucent - Proprietary
See notice on first page.

8DG09019HAAATQZZA
June 2009

Optical jumper routing


Description

The pictures below show the route of the optical jumpers.


Route using the fiber holders (code 8DG87280AAAA) which are part of the Installation
kit code 8DG87321AAAA.

Fiber Holders

Figure 121 Optical jumper route

8DG09019HAAATQZZA
June 2009

Alcatel-Lucent - Proprietary
See notice on first page.

2-113

Details of the optical jumper from the Alcatel-Lucent 1850 TSS-160 sub-rack to the
optical duct of the TSS rack.

TSS Rack
Optical duct

Fiber
Holders

Optical jumper bend radius


control device

TSS Rack Optical duct

Figure 122 Optical jumper routing details

2-114

Alcatel-Lucent - Proprietary
See notice on first page.

8DG09019HAAATQZZA
June 2009

Optical fiber

Overview
Description

This section provides the optical installation and fibering instructions for the AlcatelLucent Transport Service Switch 320/160 (TSS 320/160).

Contents

This chapter covers these topics:


Placing/removing devices into the sub-rack

3-2

XFP and XFP-E adapter module insertion/extraction

3-2

XFP module into XFP adapter insertion/extraction

3-4

SFP module insertion/extraction

3-5

Optical jumper characteristics

3-8

8DG09019HAAATQZZA
June 2009

Alcatel-Lucent - Proprietary
See notice on first page.

3-1

Placing/removing devices into the sub-rack


XFP and XFP-E adapter module insertion/extraction

The XFP adapter module can be provided with the following:


1P10GSO (1x10G synchronous optical port unit)
1x10GEPP Packet module
XFP and XFP adapter module insertion

a. After having placed the unit into the sub-rack, insert the XFP or XFP-E adapter
module in the special cavity and push on the front panel until the XFP or XFP-E
adapter module connector starts to mate with the unit connector.

Figure 123 XFP and XFP adapter module insertion

Fasten the mounting screws.

3-2

Alcatel-Lucent - Proprietary
See notice on first page.

8DG09019HAAATQZZA
June 2009

XFP and XFP-E adapter module extraction

a. Unfasten the mounting screws.


Insert the XFP-adapter hook of the extraction tool in the polarized hole on the XFP
or XFP-E adapter modules front cover.
Rotate the tool 180 degree clockwise or counterclockwise in order to adjust the tool
for the extraction.
Pull out the XFP or XFP-E adapter module from the front panel of the unit.

Figure 124 XFP and XFP-E adapter module extraction

8DG09019HAAATQZZA
June 2009

Alcatel-Lucent - Proprietary
See notice on first page.

3-3

XFP module into XFP adapter insertion/extraction


XFP module into XFP adapter insertion

a. For XFP modules inserted by the XFP adapter: Before inserting the module, move
the bale (latch) up, then insert the XFP module in the special cavity, and push on
it until the XFP module connector starts to mate with the unit connector.

Figure 125 XFP module into XFP adapter insertion


XFP module into XFP adapter extraction

a. Insert the XFP hook of the extraction tool in the available space.
Pull up the bale (latch) in order to unlock the XFP module.
Extract the XFP module from the XFP adapter using the bale (latch).

Figure 126 XFP module into XFP adapter extraction

3-4

Alcatel-Lucent - Proprietary
See notice on first page.

8DG09019HAAATQZZA
June 2009

SFP module insertion/extraction


SFP module insertion

After having placed the unit into the sub-rack, insert the SFP module in the special
cavity and push on it until the SFP module connector starts to mate with the unit
connector.

Figure 127 SFP module insertion

SFP module extraction

b. Collect the SFP Plug-in tool from the back side of the front cover.
Insert the SFP Plug-in tool in the front of the SFP module with the slide latch on
the left side.

Figure 128 SFP Plug-in tool insertion

Press the slide latch to the SFP module in order to unlock the module.

Figure 129 SFP module extraction

8DG09019HAAATQZZA
June 2009

Alcatel-Lucent - Proprietary
See notice on first page.

3-5

Pull out the SFP module from the unit.

Figure 130 SFP module extracted


END OF STEPS

Figure 131 Extraction tool code 8DG08381AAAA

Figure 132 SFP Plug-in tool

CAUTION
Possibility of personal injury
Install the Alcatel-Lucent 1850 TSS-320 and TSS-160 in a restricted access
area only. The entrance to a restricted access area is intended for qualified or
trained personnel, and access to it is controlled by a locked barrier.
These two tools are supplied with the sub-racks.
3-6

Alcatel-Lucent - Proprietary
See notice on first page.

8DG09019HAAATQZZA
June 2009

Pre-installation without SFP

To allow the pre-installation of the optical fibers into the equipment, also when there are
not the SFP optical modules, it is possible to install into the cage the LC SFP packing cap
code 1AD047980002 available in the kit code 8DG25694AAXX in quantities 16 pieces.
In figure below reported shown the assemble instructions.

SFP Cage

SFP Packing Cap

Figure 133 Packing cap assembled

8DG09019HAAATQZZA
June 2009

Alcatel-Lucent - Proprietary
See notice on first page.

3-7

Optical jumper characteristics

This section details the required codes and characteristics for fibers to be used for these
systems.
Note: all the optical jumpers used for the connection between 1850 TSS equipments and
the ODF or other equipments, must have a soft boot with a maximum length (connector
included) no more than 35 mm.
This is necessary in order to permit the subrack cover plate closure.
MU-LC connector characteristics:

Manufacturing:
Type:

MU-PC

LC-PC

Orientation:

optimizable

optimizable

Ferrule:

zirconia, diam. 1.25 mm

zirconia, diam. 1,25 mm

Boot:

rubber, blue

rubber, black

Housing:

plastic, brown

plastic, blue

Geometrical characteristics of the surface for the manufactured ferrule:


MU-PC

LC-PC

Lapping radius (mm)

10 to 20

7 to 25

Fiber shrinkage (nm)

-50

-50

Fiber protrusion (nm)

Lapping-vertex non-circularity (m)

0 to 50 0 to 50

Functional characteristics of the connectors (MU and LC):


Insertion loss @ 1310- 550 nm

Typical: 0.3 dB
Max.: 0.4 dB (random mating)

Return loss @ 1310 e 1550nm

45 dB (SPC)

Manufacturing, mechanical and environmental characteristics of the fiber

3-8

Type:

tight

Outer coating material

LSZH

Outer diameter:

2 mm

Color:

yellow

Minimum bend radius:

transient 20 mm
steady 40 mm

Alcatel-Lucent - Proprietary
See notice on first page.

8DG09019HAAATQZZA
June 2009

Operating temperature

- 5 to + 70 C

Storage temperature

- 40 to + 85 C

Dimensional and transmissive characteristics of the optical fiber:

9/125 m (sec. ITU-T G.652)

Fiber type

Diameter of the mode field @ 1310 nm 9.2 0.4 m


Diameter of the mode field @ 1550 nm 0.5 1 m
Cladding diameter

125 1 m

Cladding non-circularity

1%

Mode-field concentricity

0.5 m @ 1310nm

Cut-off wavelength

1260 nm

Attenuation @ 1310 nm

0.4 dB/km

Attenuation @ 1550 nm

0.3 dB/km

Diameter of primary coating: 245 5 m, double acrylate.

8DG09019HAAATQZZA
June 2009

Alcatel-Lucent - Proprietary
See notice on first page.

3-9

The following table shows MU-LC jumper codes required for FOADM connections.

Alcatel P/N

Length

1AB185770054

800 mm

1AB185770055

880 mm

1AB185770056

1080 mm

1AB185770010

1160 mm

L
35 mm (max)

50 mm +0 / -5

MU

LC
Boot

The following table shows the codes for the equipment-DCU connections:
- 1st configuration - Qty: 2 x TSS320
From 1st shelf TSS320 to DCU jumper - code: 1AB182400052 - length: 2,5 m.
From 2nd shelf TSS320 to DCU jumper - code: 1AB182400047 - length: 1,5 m.
- 2nd configuration - Qty: 1 x TSS320 + 1 x TSS160
From 1st shelf TSS320 to DCU jumper - code: 1AB182400052 - length: 2,5 m.
From 2nd shelf TSS160 to DCU jumper - code: 1AB182400047 - length: 1,5 m.
- 3rd configuration - Qty: 3 x TSS160
From 1st shelf TSS160 to DCU jumper - code: 1AB182400052 - length: 2,5 m.
From 2nd shelf TSS160 to DCU jumper - code: 1AB182400057 - length: 2,0 m.
From 3rd shelf TSS160 to DCU jumper - code: 1AB182400047 - length: 1,5 m.

3-10

Alcatel-Lucent - Proprietary
See notice on first page.

8DG09019HAAATQZZA
June 2009

Migration from Rel.1.x to


Rel.3.x in Alcatel-Lucent
1850 TSS rack

Overview
Description

The current procedure defines the order in which to perform the main actions in order to
upgrade the Alcatel-Lucent 1850 Transport Service Switch (TSS-320) Release 1.x
equipment to Alcatel-Lucent 1850 TSS-320 Release 3.x (3.5 KW) equipment in
greenfield and in upgrade situations.

Contents

This chapter covers these topics:


Safety rules

4-2

Migration hardware procedure (greenfield)

4-3

Migration description

4-7

Migration hardware procedure (upgrade)

4-11

20G packet processors to packet modules migration

4-13

HO to HO+LO migration (MT320LO and LOAs)

4-17

8DG09019HAAATQZZA
June 2009

Alcatel-Lucent - Proprietary
See notice on first page.

4-1

Safety rules
The use of insulated tools is recommended for all of the following actions.

In general:
Due to the possibility of very high currents in case of a short-circuit at the battery power
input, it is essential that the battery power distribution line be provided with a short
circuit back-up protection with adequate breaking capacity.

4-2

Alcatel-Lucent - Proprietary
See notice on first page.

8DG09019HAAATQZZA
June 2009

Migration hardware procedure (greenfield)


Description

Warning: Before starting, check that the main power distribution accepts cables with a
section of 25 mm.
Rack initial layout

Perform the first installation and the first cables routing as shown in the three figures
below. This configuration is designed to make future migration easier.

EMI FILTER

GENTRU

MANGTRU

UPPER AIR
BAFFLE
See detail figure 2

1850 TSS-320

LOWER AIR
BAFFLE

Figure 134 Initial rack layout

8DG09019HAAATQZZA
June 2009

Alcatel-Lucent - Proprietary
See notice on first page.

4-3

RL

1
6

HOUSEKEEPING
OUT
13
1

25

M1

IN
M4502

RA

14

A1

GND

PSFB

- A3

M4505
STUPA STUPB

15

15

M4504

Electrical point
Description

SHELF ID

8
M4503

PSFA

M4508

M4509

A1

GND

- A3

M4506
AUX CHANNELS
13

25

14

M4507

Cable
Alcatel-Lucent 1850 TSS-320
side

Rack Lamp

8DG90079AAXX

Rack alarm

Housekeeping

4
5
6
7

Shelf ID

Step up A

15 pins connector (code


1AB003110022) with the related
shell (code 1AB006030063)
25 pins connector (code
1AB003110023) with the related
shell (code 1AB 00603 0064)
Module (code 3AL79242AAXX)
Not used
Not used
8DG 90080 AAXX

Step up B

8DG 90080 AAXX

Aux Channels

25-pin connector (code


1AB003110023) with its shell
(code 1AB006030064)

Suggested cables

MA-NGTRU or
GENTRU side
RJ45 connector code
1AB074610008

1AC014910008
1AC014910012

RJ45 connectors (code


1AB074610008)
RJ45 connectors (code
1AB074610008)
1AC014910012

Figure 135 Alcatel-Lucent 1850 TSS-320 top back panel detail

4-4

Alcatel-Lucent - Proprietary
See notice on first page.

8DG09019HAAATQZZA
June 2009

Rack alarm cable

Housekeeping
cable

Rack lamp cable

M Matrix cables

Synchronization
cables

DS Matrix cables

Figure 136 Electrical cables route (left part)

8DG09019HAAATQZZA
June 2009

Alcatel-Lucent - Proprietary
See notice on first page.

4-5

Auxiliary
channel cable

Step Up cables

Power cables

Figure 137 Electrical cables route (right part)

4-6

Alcatel-Lucent - Proprietary
See notice on first page.

8DG09019HAAATQZZA
June 2009

Migration description
Description

The following steps describe the procedure to upgrade the power distribution stage of the
initial rack moving to a solution for up to 3.5 kW that uses the EMI-FILTER and the
GENTRU. Do not perform any operations that are not described in this document.
a. Switch off the STEP-UP A.
b. Switch off the Main Breaker of the line A.
c. Disconnect, cut, and remove the power cable A (between STEP-UP A and
PSF320 in slot 37).

Power cable A

Figure 138 Power cable A

d. Disconnect the cables of the line A from MA-NGTRU. Check that the section of
the cables of the line A coming from Central station are at least 25 mm; if the
section is smaller, substitute the cables .
Line A

Line B

Step-Up A

Step-Up B

Figure 139 MA-NGTRU battery line description

8DG09019HAAATQZZA
June 2009

Alcatel-Lucent - Proprietary
See notice on first page.

4-7

e. Assemble the EMI FILTER and GENTRU on the rack (using the relative
installation kits - codes 8DG08847AA and 8DG08216AA) in the position shown
in Figure 140. Connect the EMI FILTER to the GENTRU. Set the socket
connectors (that are parts of the GENTRU installation kit code 8DG08216AA) on
the GENTRU as indicated in the Figure 141.
Q.ty 3
screws M3

EMI FILTER

GENTRU

Q.ty 4
screws M6x12

Figure 140 EMI FILTER and GENTRU connection

SLOTS

M29

M56

M65

Metal
Plastic

Figure 141 GENTRU socket setting

f. Insert the STEP-UP A and B in slots 2 and 3 into the GENTRU. Connect the
STEP-UP cables and the rack lamp cable on the GENTRU.
g. Connect the new power cable (code 8DG08775AA) which is inserted in the kit
(code 8DG08845AA) from the PSF320 unit plugged in slot 37 to STEP-UP A
inserted in slot 2 of the GENTRU.
4-8

Alcatel-Lucent - Proprietary
See notice on first page.

8DG09019HAAATQZZA
June 2009

Remove
Step Up cables

Power cables

Figure 142 New cables connection

h. Crimp the 90 lug inserted in the GENTRU installation kit (code 8DG08216AA)
on the 25 mm cables of the line A from Central station, and connect them to the
EMI FILTER (as shown in Figure 143).

8DG09019HAAATQZZA
June 2009

Alcatel-Lucent - Proprietary
See notice on first page.

4-9

i. Remove the GND cable from MA-NGTRU (if present). Terminate it, crimping
the 90 lug, and connect it to the EMI FILTER (as shown in Figure 143).
Line A

Lugs

Line B

GND

Cover

Figure 143 Connection of Central station lines cable to EMI FILTER

j. Switch on the Main Breaker of the line A.


k. Switch on the STEP-UP A.
l. Repeat Steps a, b, c, d, g, h, i, j, and k for line B and for the PSF320 plugged in
slot 39.
m. Remove the MA-NGTRU from the rack.

4-10

Alcatel-Lucent - Proprietary
See notice on first page.

8DG09019HAAATQZZA
June 2009

Migration hardware procedure (upgrade)


Description

Warning: It is possible to do these operations if there is an assembled TSS-320 sub-rack


in the rack. For different starting points, it is necessary to analyze the racks initial layout
to find the easy way to migrate from MA-NGTRU to GENTRU.
Rack initial layout

Before starting with the migration, it is necessary to route all the cables in accordance
with Figure 136 on page 4-5 and Figure 137 on page 4-6.
Note: Use the following steps to reach the end of the cable routing described in
Figure 136 and Figure 137. (this note applies to Matrix cards in slots 10 and 11
and POW320 cards in slots 37 and 39, the Timing interface).

1. Disconnect and/or cut the connector (if necessary)


2. route and/or terminate (if previously cut) the appropriate connector. Connectors
are included in the TSS-320 installation kit code 8DG08845AA)
3. reconnect only one cable per time.
WARNING: Before operating on the timing interface in slots 37 and 39, check the
synchronization sources configured on the network equipment in order to avoid a switch
to a free-running mode condition.
Migration description

The following steps describe the procedure to upgrade the power distribution stage of the
initial rack moving to a solution for up to 3.5 kW that uses the EMI-FILTER and the
GENTRU. Do not perform any operations that are not described in this document.
In this case, the layout of the rack is already installed, so it is necessary to move the TSS320 subrack and the MA-NGTRU into the position shown in Figure 134 on page 4-3,
following the procedure below.
WARNING: Before moving the TSS-320 shelf to its final position, check that the optical
fibers and cables have the necessary overlength.

a. Remove the air deflectors from the top and from the bottom of the TSS-320
subrack.
Switch off the STEP-UP A.
Switch off the Main Breaker of the line A.
Disconnect the Power cable A from POW320 unit inserted in slot 37.
8DG09019HAAATQZZA
June 2009

Alcatel-Lucent - Proprietary
See notice on first page.

4-11

Disconnect the coax cables from the POW320 in slot 37.


Remove the POW320 unit from slot 37 and replace it with the PSF320 unit.
Connect the timing adapter COAXA320 (code 8DG08739AA) on the 9-pin
Sub-D connector placed on the front plate of the PSF320 unit.
Reconnect the coax cables on the adapter COAXA320 and the power cable A on
the PSF320 power connector.
Disconnect the cables of the line A from MA-NGTRU. Check that the section of
the cables of the line A coming from Central station are at least 25 mm; if the
section is smaller, substitute the cables.
WARNING: Leave at least 1 meter of overlength, in order to move the
MA-NGTRU
Switch on the Main Breaker of the line A.
Switch off the STEP-UP B.
Switch off the Main Breaker of the line B.
Disconnect the Power cable B from POW320 unit in slot 39.
Disconnect the coax cables from the POW320 in slot 39.
Remove the POW320 unit from slot 39 and replace it with the PSF320 unit.
Connect the timing adapter COAXA320 (code 8DG08739AA) on the 9-pin
Sub-D connector placed on the front plate of the PSF320 unit.
Reconnect the coax cables on the adapter COAXA320 and the power cable B on
the PSF320 power connector.
Disconnect the cables of the line B from MA-NGTRU. Check that the section of
the cables of the line B coming from Central station are at least 25 mm; if the
section is smaller, substitute the cables.
WARNING: Leave at least 1 meter of overlength, in order to move the
MA-NGTRU.
Switch on the Main Breaker of the line B.
Move (if necessary) the Alcatel-Lucent 1850 TSS-320 sub-rack in the right
position (holes 57, 61, and 67 - see Figure 134).
Move the MA-NGTRU to its temporary position (holes 31 and 29 - see Figure
134).
Follow the same steps described in paragraph Migration hardware procedure
(greenfield) on page 4-3, as it is a greenfield installation
Assemble the new air deflectors (code 8DG08844AA and 8DG08834AA) on the
top and on the bottom of the TSS-320 sub-rack.

4-12

Alcatel-Lucent - Proprietary
See notice on first page.

8DG09019HAAATQZZA
June 2009

20G packet processors to packet modules migration


Description

Table 19 reports the codes of the Circuit Pack that need to migrate from Rel.1.x to
Rel.3.x.
Table 19: Circuit Packs needed for migration
Rel.1.x PACKS

Rel.3.x PACKS

CODE

MNEMONIC

CODE

MNEMONIC

3AL92118AA
3AL92117AA
3AL92116AA
3AL92183AA
3AL92114AA

PIMMS
PIM1GE
PIM10GE
PIM DUMMY
PP20G

8DG08226AA
8DG08051AA
8DG08049AA
3AL92154AB
-

10GMSPP
10X1GEPP/10X1GESY
1X10GEPP/1X10GESY
FULL SLOT DUMMY
-

Note: To complete the migration, it is necessary to replace all of the old dummy plates
with the new dummy plates.

Below are the new dummy plate codes:


full slot dummy plate

3AL92154AAAA becomes 3AL92154ABAA

1/2 slot dummy plate

3AL92156AAAA becomes 3AL92156ABAA

1/2 slot mechanical adapter 3AL92173AAAA becomes 8DG87289AAAA


Table 20 describes the position (slots) of the PP20G unit and PIM before and after the
migration operations.

8DG09019HAAATQZZA
June 2009

Alcatel-Lucent - Proprietary
See notice on first page.

4-13

Table 20: Position (slots) of the PP20G unit and PIM before and after the migration
operations
WAS

4-14

BECOME

PP20G SLOT

PIM Pos.

PP BOARD SLOT

2/3
2/3
4/5
4/5
6/7
6/7
8/9
8/9
12/13
12/13
14/15
14/15
16/17
16/17
18/19
18/19

1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2

2
3
4
5
6
7
8
9
12
13
14
15
16
17
18
19

Alcatel-Lucent - Proprietary
See notice on first page.

NOTE

See example Figure


144

8DG09019HAAATQZZA
June 2009

Alcatel-Lucent 1850 TSS-320 sub-rack initial layout


PP20G in SLOTS 6/7

PIMMS in POS. 1

PIMMS in POS. 2

PIM1GE in POS.1

PIM10GE in POS.2

PP20G in SLOTS 8/9

Alcatel-Lucent 1850 TSS-320 subrack final layout

10GMSPP in SLOT 6

10GMSPP in SLOT 7

10x1GEPP /
10X1GESY in SLOT 8
1x10GEPP /
1X10GESYin SLOT 9

Figure 144 20G packet processors to packet modules migration layout

8DG09019HAAATQZZA
June 2009

Alcatel-Lucent - Proprietary
See notice on first page.

4-15

WARNING: Before starting with the operations, check that the optical fibers connected
to the Packet Processors (PP20G + PIMs) have the necessary overlength to be connected
to the new Packet Modules (PP10GE/GESY, PP1GE/GESY and MSPP). If not, it is
necessary to change all the optical fibers.
Migration steps description

a. Disconnect the optical fibers from the PIMs plugged in the PP20G circuit card.
b. Remove the PP20G Aggregator card.
c. Insert the new units into the sub-rack in accordance with Table 19 and Table 20.
d. Reconnect the optical fibers taking into account the change in the SFP numbering
(see Figure 145).
PIM1GE

6 Rx
Tx
7 Rx
Tx
8 Rx
Tx
9 Rx
Tx
10 Rx
Tx

10x1GESY

10x1GEPP

1 Tx
Rx
2 Tx
Rx
3 Tx
Rx
4 Tx
Rx
5 Tx
Rx

1
2
3
4
5
6
7
8
9
10

Tx
Rx
Tx
Rx
Tx
Rx
Tx
Rx
Tx
Rx

Tx
Rx
Tx
Rx
Tx
Rx
Tx
Rx
Tx
Rx

1x10GESY

1x10GEPP

PIM10GE

Tx

2
3

Rx

4
5

Tx

7
8

Rx

9
10

Figure 145 SFP positions

4-16

Alcatel-Lucent - Proprietary
See notice on first page.

8DG09019HAAATQZZA
June 2009

HO to HO+LO migration (MT320LO and LOAs)


Description

The migration from HO to HO+LO requires the replacement of HO Matrix units with
HO+LO matrix units and the insertion of LOA10G adapter cards in reserved slots. This
could imply moving the already inserted cards to other free slots with traffic hit, not
needed if reserved slots were left free as per handbook and DRACO configurator
recommendations.
The following steps describe the procedure to upgrade from the MT320 to the new
MT320LO.
1
2

Disconnect the electrical cables from standby MT320.


Replace the standby MT320 with the new MT320LO.

Reconnect the electrical cables to the new MT320LO.

Wait till the EPS led becomes orange (not blinking) and the status led becomes
green. Operate a manual EPS to make the new MT320LO active.

Disconnect the electrical cables from MT320 (in standby).

Replace the MT320 with the new MT320LO.

Reconnect the electrical cables to the new MT320LO.

Figure 146 reports the Alcatel-Lucent 1850 TSS-320 subrack layout before and after the
migration.
Table 21 reports all the possible configurations of LOA10G card into the Alcatel-Lucent
1850 TSS-320 equipment in Release 3.x.
Table 21: Possible configurations of LOA10G card into the Alcatel-Lucent 1850 TSS-320
equipment in Release 3.x.
LOA10G

SLOTS

Note

1+1

21+24 or 22+24 or 35+33 or 36+33


21&22+24 or 21&35+24 or 21&35+33 or 21&36+24 or
21&36+33
22&35+24 or 22&35+33 or 22&36+24 or 22&36+33 or
35&36+33
21&22&35&36+24+33

10G LO with 10G protection

2+1
4+2

20G LO with 10G protection


40G LO with 20G protection

For each configuration, choose the right slots combination based on the free slots
position in the subrack.

If there isnt any possibility to plug the LOA10G card in the chosen slot due to the
presence of other circuit packs, please move those cards in other free slots, taking into
account the length and the routing of the optical fibers already connected.
8DG09019HAAATQZZA
June 2009

Alcatel-Lucent - Proprietary
See notice on first page.

4-17

Alcatel-Lucent 1850 TSS-320 subrack initial layout

MT320 in SLOTS
10 and 11

Alcatel-Lucent 1850 TSS-320 subrack final layout

MT320LO in SLOTS
10 and 11

LOA10G in SLOTS
21 and 22

LOA10G in SLOTS
35 and 36,

LOA10G in SLOTS
24 and 33

Figure 146 HO to HO+LO migration (MT320LO and LOAs)

4-18

Alcatel-Lucent - Proprietary
See notice on first page.

8DG09019HAAATQZZA
June 2009

Suggested cables

Overview
Alcatel-Lucent 1850 TSS-320 suggested cables

REF

CABLE TYPE

CONNECTION
TYPE

DIA (mm) or
SECT. (mm2)
INT.

NV P/N.
(FACTORY P/N)

NOTE

8DG08775AAAA

EXT.

Power supply

75 Ohm Coax Cable

Solder/crimp

3.1

1AC001100013

120 Ohm Cable

Solder

1AC004370004

2/3/5

LAN Cable

crimp

1AC016760003

Step up Alarm

crimp

8DG90080AA

Rack Lamp

Solder

8DG90079AA

HK Cable

Solder

1AC014910012

Rack Alarm

Solder

1AC014910008

NOTES :
1 Terminate with 75-ohm coax connector Male P/N 1AB061220017.
2 Terminate with 75-ohm coax connector Fem. P/N 1AB009790019.
3 Terminate with Balun connector P/N 1AB158340001.
4 Terminate with RJ45 connector P/N 1AB074610008.
5 Terminate with RJ11 connector P/N 1AB04280001.
6 Terminate with Sub D 25-pin connector P/N 1AB003110023.
7 Terminate with Sub D 15-pin connector P/N 1AB003110022.

8DG09019HAAATQZZA
June 2009

Alcatel-Lucent - Proprietary
See notice on first page.

A-1

Alcatel-Lucent 1850 TSS-160 suggested cables

REF

CABLE TYPE

CONNECTION
TYPE

DIA (mm) or
SECT. (mm2)
INT.

EXT.

NV P/N.
(FACTORY P/N)

NOTE

10

PSF320 Power

8DG87298AAAA

PSF320
Synchronization

8DG08739AAAA

12

EC320 CT

3AL89583AAAA

13

MT160

14

Back panel Alarm


Step up A/B

8DG90080AAAA

15

Back panel RL

8DG87347AAAA

16

Back panel RA

17

Back panel
Housekeeping

NOTES :

A-2

See Installation kit 8DG87321AAAA


Connector code 1AB040970018, 1AB044280028
Sub D Connector, Contact Crimp

See LCPC
Connector code 1AB061220018
Coax. Connector 1.0/2.3

See Craft TGerm. Cable kit 3AL89585AAAA

Connector code 1AB074610008


RJ45

See Installation kit 8DG87321AAAA


Connector code 1AB074610008
RJ45

Connector code 1AB003110022


Sub D Connector 15 p Male

Connector code 1AB003110023


Sub D Connector 25 p Male

Alcatel-Lucent - Proprietary
See notice on first page.

8DG09019HAAATQZZA
June 2009

Installation kit

Overview
Alcatel-Lucent 1850 Transport Service Switch (TSS-320) ETSI installation kit - P/N 8DG08845AA
P/N

Description

Qty.

1AB 00311 0022

CON-PANEL*CON-DSUB MAL*15*WIRS*AU.8

1AB 00311 0023

CON-PANEL*CON-DSUB MAL*25*WIRS*AU.8

1AB 00428 0001

CON- CBLFT MAL*4*PIERC*AU1.27

1AB 00603 0063

CON-ACCESS*COVER CON-DSUB

1AB 00603 0064

CON-ACCESS*COVER CON-DSUB

1AB 06122 0018

CON-COAX*COAX 1.0/2.3

1AB 07461 0008

CON-CBLRD*CON-I/O JACKS> MAL*8*ID*AU1.27

11

1AD 00090 0008

WASHER*EXT-T 6.4mmx11mmx700um/M6

1AD 00915 0001

SCREW*HEX-HD-WF*HEX/SLTD M6x12mm*SS

3AL 92507 AAAA

MA-LEFT SHELF ASSEMBLED

3AL 92508 AAAA

MA-RIGHT SHELF ASSEMBLED

8DG 08775 AAAA CA-ETSI POWER CABLE 5xAWG8

8DG 08834 AAAA RSA-ETSI LOWER BAFFLE - 1850 R3

8DG 90079 AAAA CA-RACK LAMP CORD

8DG 90080 AAAA CA-STEP-UP ALARM CORD

8DG09019HAAATQZZA
June 2009

Alcatel-Lucent - Proprietary
See notice on first page.

B-1

Kit 2-Mb/s Aux channel 75-ohm kit - P/N 3AL38432AA


P/N
1AB 06122 0017

Description
CON-COAX*MAL*1*CRIMP, 75 ohm

3AN 44672 AAAA Adhesive label

Qty.
1
1

1AB 06122 0017

CON-COAX*MAL*1*CRIMP, 75 ohm

1AD 01376 0013

BAG*100X150 MM , POLYETHYLENE FILM 0.05

1AB 06122 0017

CON-COAX*MAL*1*CRIMP, 75 ohm

1AB 06122 0017

CON-COAX*MAL*1*CRIMP, 75 ohm

Kit 2-Mb/s Aux channel 120-ohm kit - P/N 3AL38433AA


P/N

Description

1AB 00979 0019

CON-COAX*FEM*1*WIRS, 50 ohm

1AB 06122 0017

CON-COAX*MAL*1*CRIMP, 75 ohm

1AB 00979 0019

CON-COAX*FEM*1*WIRS, 50 ohm

1AB 06122 0017

CON-COAX*MAL*1*CRIMP, 75 ohm

1AB 00979 0019

CON-COAX*FEM*1*WIRS, 50 ohm

1AB 00979 0019

CON-COAX*FEM*1*WIRS, 50 ohm

1AB 15834 0001

CON-COAX*MAL*2*ID, 75 ohm

1AB 15834 0001

CON-COAX*MAL*2*ID, 75 ohm

3AN 44672 AAAA ADHESIVE LABEL

B-2

Qty.

1AB 15834 0001

CON-COAX*MAL*2*ID, 75 ohm

1AB 06122 0017

CON-COAX*MAL*1*CRIMP, 75 ohm

1AB 06122 0017

CON-COAX*MAL*1*CRIMP, 75 ohm

1AD 01376 0012

BAG*350X500 MM, POLYETHYLENE FILM 0.06

1AB 15834 0001

CON-COAX*MAL*2*ID, 75 ohm

Alcatel-Lucent - Proprietary
See notice on first page.

8DG09019HAAATQZZA
June 2009

Kit - GENTRU ETSI installation kit P/N 8DG08216AA


P/N

Description

Qty.

8DG 08379 AAAA MA-RIGHT INSULATING PROTECTION ASS.

8DG 08377 AAAA MA-LEFT INSULATING PROTECTION

8DG 08097 AAAA MA-LUG INSULATING COVER ASS.

14

8DG 08088 AAAA MPP-BRACKET 19"/21"

8DG 07731 AAAA MPP-PROTECTION SOCKET LABEL

3AL 92210 AAAA

MPP-PROTECTION SOCKET

3AL 92207 AAAA

MPP-BATTERY DISTRIBUTION SOCKET

1AD 00915 0015

SCREW*HEX-HD-WF*HEX/SLTD M6*SS

14

1AD 00915 0001

SCREW*HEX-HD-WF*HEX/SLTD M6x12mm*SS

1AD 00886 0042

SCREW*RCH-HD*XR-PH M4x10mm*SS

24

1AD 00090 0008

WASHER*EXT-T6.4mmx11mmx700um/M6

1AB 05153 0094

LUG*PIN*CRIMP UNINSUL*7.62mm/8.13mm*6>

14

1AB 05009 0002

CON-CONTACT*WIRS MALE

1AB 04428 0002

CON-CONTACT*WIRS FEMALE

1AB 04097 0009

CON-PANEL*CON-DSUB

1AB 00603 0063

CON-ACCESS*COVER CON-DSUB

Kit MA-NGTRU ETSI installation kit P/N 3AL92196AA


P/N

Description

Qty.

3AL38427ABAB

EMA-NGTRU2 BASE

8DG07567AAAA

KIT-INSTALLACTION KIT NGTRU2

8DG07558AAAA

MA-COMPLETE FRONT COVER 4G

8DG07574AAAA

MPP-RIGHT BRACKET

1AD013170001

SCREW*RCH-HD*TORX M2.5x6mm

3AN49331AAAA

MPP - 11 X 45 LABEL

8DG07626AAAA

MPP-LEFT BRACKET

3AN42506AAAA

CE MARK LABEL

8DG09019HAAATQZZA
June 2009

Alcatel-Lucent - Proprietary
See notice on first page.

B-3

Kit - Alcatel-Lucent 1850 TSS-160 ETSI shelf assembly P/N 8DG87321AAAA

B-4

P/N

Description

Qty.

8DG 87273 AAAA

MPP - LEFT SUPPORT

8DG 87272 AAAA

MPP - RIGHT SUPPORT

1AD 00886 0021

SCREW*RCH-HD*XR-PH M4x8mm*SS

8DG 87274 AAAA

MPP - SUPPORT

3AL 94526 AAAA

MPP - UNLOOSABLE TC SCREW

14

8DG 87288 AAAA

MPP - FIBER CONVEYOR

8DG 87275 AAAA

MPP - FIBER CONVEYOR

8DG 87286 AAAA

MPP - BAR

8DG 87280 AAAA

MPP - FIBER HOLDER

48

8DG 87312 AAAA

MPP - PLATE

8DG 87313 AAAA

MPP - BRACKET

1AD 00886 0004

SCREW*RCH-HD*XR-PH M2.5x6mm*SS

8DG 87298 AAAA

CA-ETSI POWER CABLE 3xAWG8

1AD 00915 0001

SCREW*HEX-HD-WF*HEX/SLTD M6x12mm*SS

1AD 00090 0008

WASHER*EXT-T 6.4mmx11mmx700um/M6

1AD 00087 0136

WASHER*PLAIN 6.4mmx12.5mmx1.6mm/M6

1AB 00311 0023

CON-PANEL*CON-DSUB MAL*25*WIRS*AU.8

1AB 00311 0022

CON-PANEL*CON-DSUB MAL*15*WIRS*AU.8

1AB 07461 0008

CON-CBLRD*CON-I/O JACKS> MAL*8*ID*AU1.27

8DG 90080 AAAA

CA-STEP-UP ALARM CORD

1AB 00603 0190

CON-ACCESS*METAL HOOD CON-DSUB

1AB 00603 0189

CON-ACCESS*METAL HOOD

8DG 87347 AAAA

CA-RACK LAMP CORD

1AB 06122 0018

CON-COAX*COAX 1.0/2.3 MAL*1*CRIMP*75Ohm

1AB 06122 0018

CON-COAX*COAX 1.0/2.3 MAL*1*CRIMP*75Ohm

1AB 06122 0018

CON-COAX*COAX 1.0/2.3 MAL*1*CRIMP*75Ohm

1AB 06122 0018

CON-COAX*COAX 1.0/2.3 MAL*1*CRIMP*75Ohm

Alcatel-Lucent - Proprietary
See notice on first page.

8DG09019HAAATQZZA
June 2009