PRECAST/
PRESTRESSED CONCRETE I
NSTI
TUTE NORTHEAST

PCI

NEXT F BEAMS

sour
ces bel
i
eved t
o be r
el
i
abl
e. PCINor
t
heastori
t
s m em ber
shi
ps shal
lnotbe r
esponsi
bl
ef
orany er
r
or
s,om i
ssi
on

4" TOP FLANGE

The det
ai
l
s shown ar
e gui
del
i
nes and shoul
d notbe consi
der
ed st
andar
ds. The i
nf
or
m at
i
on has been obt
ai
ned f
r
om

- RECOMMENDED USAGE

I
SSUE DATE: 03 / 10 / 15

DI
SCLAI
M ER:

NEXT BEAM

WEARING SURFACE

SHEET: NEXT 01

CHANGED ORDER OF BEAM TYPES


03 /2016
2

CHANGED RAI
LI
NG TO CONCRETE BARRI
ER

NEXT D BEAMS
WEARING SURFACE

10 /2015

NEXT E BEAMS

NORTHEAST EXTREM E TEE (


NEXT)BEAM DETAI
LS

REVI
SI
ONS

8" MINIMUM
INTEGRAL DECK/TOP FLANGE
2

DESCRI
PTI
ON

4" INTEGRAL PARTIAL DECK/


TOP FLANGE
WEARING SURFACE

DATE

4" MINIMUM
REINFORCED CIP CONCRETE DECK

NO.

8" MINIMUM
REINFORCED CIP CONCRETE DECK

2. CREST VERTICAL CURVES: IF THE CAMBER IS LESS THAN THE CURVE


ORDINATE, THE DETAILS WILL BE SIMILAR TO THE TANGENT PROFILE
DETAILS.
WEARING SURFACE

NEXT F BEAMS
5. THE ESTIMATED CAMBER USED FOR THE VARIABLES NOTED ABOVE
SHOULD BE BASED ON THE ESTIMATED CAMBER AT ERECTION.

CONSTANT THICKNESS OVERLAY

NEXT F BEAMS - TANGENT PROFILE

MINIMUM TOPPING THICKNESS AT ENDS IF VERTICAL


CURVE ORDINATE IS LARGER THAN CAMBER
THICKER TOPPING IF CAMBER IS LESS THAN ORDINATE

THICKER TOPPING THICKNESS AT MID-SPAN IF VERTICAL


CURVE ORDINATE IS LARGER THAN CAMBER
MINIMUM TOPPING THICKNESS IF CAMBER IS LESS THAN ORDINATE

THICKNESS VARIES

OPTION 1: VARY TOPPING THICKESS

CURB/BARRIER HEIGHT VARIES


OVERLAY THICKNESS VARIES

NEXT F BEAMS - CREST VERTICAL CURVE PROFILE

DI
SCLAI
M ER:

CONSTANT HEIGHT CURB/BARRIER

NEXT F - PROFI
LE ACCOMMODATI
ON DETAI
LS

MINIMUM TOPPING THICKNESS AT MID-SPAN

6. FOR MORE INFORMATION ON ACCOMMODATION OF PROFILES AND


CAMBER, SEE PCI NORTHEAST PROFILE AND CAMBER MANAGEMENT
GUIDE.

NORTHEAST EXTREM E TEE (


NEXT)BEAM DETAI
LS

THICKER TOPPING THICKNESS AT ENDS


CAUSED BY BEAM CAMBER

CONSTANT THICKNESS
TOPPING

I
SSUE DATE: 03 / 10 / 15
SHEET: NEXT 02

CHANGED RAI
LI
NG TO CONCRETE BARRI
ER
10 /2015

DATE

NEXT F BEAMS - SAG VERTICAL CURVE PROFILE

REVI
SI
ONS

OPTION 2: VARY OVERLAY THICKESS

DESCRI
PTI
ON

MINIMUM TOPPING THICKNESS AT MID-SPAN

NO.

THICKER TOPPING THICKNESS AT ENDS


CAUSED BY VERTICAL CURVE ORDINATE
PLUS BEAM CAMBER

Nor
t
heasti
s suppl
yi
ng i
nf
or
m at
i
on onl
y. PCINor
t
heasti
s notr
ender
i
ng engi
neer
i
ng orot
herpr
of
essi
onalser
vi
ces

4" TOP FLANGE

ordam ages ar
i
si
ng outoft
hi
si
nf
or
m at
i
on. PCINor
t
heasthas publ
i
shed t
hi
s wor
k wi
t
ht
he under
st
andi
ng t
hatPCI

4. THE ENGINEER SHOULD ACCOUNT FOR THE ESTIMATED VARIABLE


THICKNESS TOPPING IN THE DESIGN OF THE BEAM.

sour
ces bel
i
eved t
o be r
el
i
abl
e. PCINor
t
heastori
t
s m em ber
shi
ps shal
lnotbe r
esponsi
bl
ef
orany er
r
or
s,om i
ssi
on

TM

PCI

3. THE ENGINEER SHOULD DETAIL THE ANTICIPATED VARIABLE


THICKNESS OF THE TOPPING OR OVERLAY ON THE PLANS BASED ON
THE ESTIMATED CAMBER. THE PLANS SHOULD INCLUDE NOTES
REQUIRING SURVEY OF THE BEAMS AFTER ERECTION, AND THEN
ADJUST THE TOPPING THICKNESS AS REQUIRED. THE SAME APPLIES
TO THE HEIGHT OF THE CURB OR BARRIER.

The det
ai
l
s shown ar
e gui
del
i
nes and shoul
d notbe consi
der
ed st
andar
ds. The i
nf
or
m at
i
on has been obt
ai
ned f
r
om

PRECAST/
PRESTRESSED CONCRETE I
NSTI
TUTE NORTHEAST

1. THE DETAILS SHOWN DEPICT VARYING THE THICKNESS OF THE CONCRETE


TOPPING. ANOTHER OPTION IS TO VERY THE THICKNESS OF THE OVERLAY.
NOTE THAT THE HEIGHT OF THE CURB OR PARAPET WILL STILL VARY.

REINFORCED CIP CONCRETE DECK


MINIMUM THICKNESS AS PER STATE STANDARDS
FOR TYPICAL BEAM BRIDGES

t
hr
ough t
hi
s gui
del
i
ne. I
fsuch ser
vi
ces ar
er
equi
r
ed,pl
ease seek an appr
opr
i
at
e pr
of
essi
onal
.

WWW.
PCI
NE.
ORG

NOTES

2. CREST VERTICAL CURVES: IF THE CAMBER IS LESS THAN THE CURVE


ORDINATE, THE DETAILS WILL BE SIMILAR TO THE TANGENT PROFILE
DETAILS.

TM

PCI

4. THE ENGINEER SHOULD ACCOUNT FOR THE ESTIMATED VARIABLE


THICKNESS TOPPING IN THE DESIGN OF THE BEAM.

NEXT E BEAMS
5. THE ESTIMATED CAMBER USED FOR THE VARIABLES NOTED ABOVE
SHOULD BE BASED ON THE ESTIMATED CAMBER AT ERECTION.

THICKNESS VARIES

MINIMUM TOPPING THICKNESS AT ENDS IF VERTICAL


CURVE ORDINATE IS LARGER THAN CAMBER
THICKER TOPPING IF CAMBER IS LESS THAN ORDINATE

THICKER TOPPING THICKNESS AT MID-SPAN IF VERTICAL


CURVE ORDINATE IS LARGER THAN CAMBER
MINIMUM TOPPING THICKNESS IF CAMBER IS LESS THAN ORDINATE

OPTION 1: VARY TOPPING THICKESS

NEXT E BEAMS - CREST VERTICAL CURVE PROFILE


CURB/BARRIER HEIGHT VARIES

OVERLAY THICKNESS VARIES

10 /2015

DATE

NEXT E BEAMS - SAG VERTICAL CURVE PROFILE

REVI
SI
ONS

OPTION 2: VARY OVERLAY THICKESS

DESCRI
PTI
ON

MINIMUM TOPPING THICKNESS AT MID-SPAN

NO.

THICKER TOPPING THICKNESS AT ENDS


CAUSED BY VERTICAL CURVE ORDINATE
PLUS BEAM CAMBER

CHANGED RAI
LI
NG TO CONCRETE BARRI
ER

CONSTANT THICKNESS TOPPING

I
SSUE DATE: 03 / 10 / 15

CONSTANT THICKNESS OVERLAY

NEXT E BEAMS - TANGENT PROFILE

SHEET: NEXT 04

DI
SCLAI
M ER:

CONSTANT HEIGHT CURB/BARRIER

NEXT E - PROFI
LE ACCOMMODATI
ON DETAI
LS

MINIMUM TOPPING THICKNESS AT MID-SPAN

6. FOR MORE INFORMATION ON ACCOMMODATION OF PROFILES AND


CAMBER, SEE PCI NORTHEAST PROFILE AND CAMBER MANAGEMENT
GUIDE.

NORTHEAST EXTREM E TEE (


NEXT)BEAM DETAI
LS

THICKER TOPPING THICKNESS AT ENDS


CAUSED BY BEAM CAMBER

Nor
t
heasti
s suppl
yi
ng i
nf
or
m at
i
on onl
y. PCINor
t
heasti
s notr
ender
i
ng engi
neer
i
ng orot
herpr
of
essi
onalser
vi
ces

4" INTEGRAL PARTIAL DECK/


TOP FLANGE

3. THE ENGINEER SHOULD DETAIL THE ANTICIPATED VARIABLE


THICKNESS OF THE TOPPING OR OVERLAY ON THE PLANS BASED ON
THE ESTIMATED CAMBER. THE PLANS SHOULD INCLUDE NOTES
REQUIRING SURVEY OF THE BEAMS AFTER ERECTION, AND THEN
ADJUSTMENT OF THE TOPPING THICKNESS AS REQUIRED. THE SAME APPLIES
TO THE HEIGHT OF THE CURB OR BARRIER.

ordam ages ar
i
si
ng outoft
hi
si
nf
or
m at
i
on. PCINor
t
heasthas publ
i
shed t
hi
s wor
k wi
t
ht
he under
st
andi
ng t
hatPCI

sour
ces bel
i
eved t
o be r
el
i
abl
e. PCINor
t
heastori
t
s m em ber
shi
ps shal
lnotbe r
esponsi
bl
ef
orany er
r
or
s,om i
ssi
on

WEARING SURFACE

The det
ai
l
s shown ar
e gui
del
i
nes and shoul
d notbe consi
der
ed st
andar
ds. The i
nf
or
m at
i
on has been obt
ai
ned f
r
om

REINFORCED CIP CONCRETE DECK


4" MINIMUM

PRECAST/
PRESTRESSED CONCRETE I
NSTI
TUTE NORTHEAST

1. THE DETAILS SHOWN DEPICT VARYING THE THICKNESS OF THE CONCRETE


TOPPING. ANOTHER OPTION IS TO VERY THE THICKNESS OF THE OVERLAY.
NOTE THAT THE HEIGHT OF THE CURB OR PARAPET WILL STILL VARY.

t
hr
ough t
hi
s gui
del
i
ne. I
fsuch ser
vi
ces ar
er
equi
r
ed,pl
ease seek an appr
opr
i
at
e pr
of
essi
onal
.

WWW.
PCI
NE.
ORG

NOTES

2. CREST VERTICAL CURVES: IF THE CAMBER IS LESS THAN THE CURVE


ORDINATE, THE DETAILS WILL BE SIMILAR TO THE TANGENT PROFILE
DETAILS.

NEXT D BEAMS
5. THE ESTIMATED CAMBER USED FOR THE VARIABLE NOTED ABOVE
SHOULD BE BASED ON THE ESTIMATED CAMBER AT ERECTION.
MINIMUM TOP FLANGE THICKNESS AT MID-SPAN

CONSTANT HEIGHT CURB/BARRIER


1

CONSTANT OVERLAY THICKNESS

NEXT D BEAMS - TANGENT PROFILE


TOP FLANGE
THICKNESS VARIES

THICKER TOP FLANGE THICKNESS AT MID-SPAN IF VERTICAL


CURVE ORDINATE IS LARGER THAN CAMBER
MINIMUM TOP FLANGE THICKNESS IF CAMBER IS LESS THAN ORDINATE

OPTION 1: VARY FLANGE THICKESS

BARRIER/CURB HEIGHT VARIES


OVERLAY THICKNESS VARIES

NEXT D BEAMS - CREST VERTICAL CURVE PROFILE

10 /2015
1

FLANGE ADJUSTMENT FOR PROFILE

DATE

FLANGES OVER 10 1/2"

NO.

VARIES

FLANGES UNDER 10 1/2"

OVER 10 "

10 "

VARIES

NORMAL DECK REINFORCEMENT

#4 @ 6"
2 "

2-#4

REVI
SI
ONS

#4 @ 6"

NEXT D BEAMS - SAG VERTICAL CURVE PROFILE

DESCRI
PTI
ON

OPTION 2: VARY OVERLAY THICKESS

CHANGED RAI
LI
NG TO CONCRETE BARRI
ER

MINIMUM TOP FLANGE THICKNESS AT MID-SPAN

8" TO

THICKER TOP FLANGE THICKNESS AT ENDS


CAUSED BY VERTICAL CURVE ORDINATE
PLUS BEAM CAMBER

DI
SCLAI
M ER:

CONSTANT FLANGE THICKNESS

I
SSUE DATE: 03 / 10 / 15

MINIMUM TOP FLANGE THICKNESS AT ENDS IF VERTICAL


CURVE ORDINATE IS LARGER THAN CAMBER
THICKER TOPPING IF CAMBER IS LESS THAN ORDINATE

NEXT D - PROFI
LE ACCOMMODATI
ON DETAI
LS

NORTHEAST EXTREM E TEE (


NEXT)BEAM DETAI
LS

6. FOR MORE INFORMATION ON ACCOMMODATION OF PROFILES AND


CAMBER, SEE PCI NORTHEAST PROFILE AND CAMBER MANAGEMENT
GUIDE.

SHEET: NEXT 03

THICKER TOP FLANGE THICKNESS AT ENDS


CAUSED BY BEAM CAMBER

Nor
t
heasti
s suppl
yi
ng i
nf
or
m at
i
on onl
y. PCINor
t
heasti
s notr
ender
i
ng engi
neer
i
ng orot
herpr
of
essi
onalser
vi
ces

4. THE ENGINEER SHOULD ACCOUNT FOR THE ESTIMATED VARIABLE


THICKNESS TOP FLANGE AND/OR TOPPING IN THE DESIGN OF THE BEAM.

ordam ages ar
i
si
ng outoft
hi
si
nf
or
m at
i
on. PCINor
t
heasthas publ
i
shed t
hi
s wor
k wi
t
ht
he under
st
andi
ng t
hatPCI

TM

PCI

3. THE ENGINEER SHOULD DETAIL THE ANTICIPATED VARIABLE


THICKNESS OF THE TOP FLANGE OR OVERLAY ON THE PLANS BASED ON
THE ESTIMATED CAMBER. THE PLANS SHOULD INCLUDE NOTES
REQUIRING SURVEY OF THE BEAMS AFTER ERECTION, AND THEN
ADJUSTMENT OF THE OVERLAY THICKNESS MAY BE REQUIRED.
THE SAME APPLIES TO THE HEIGHT OF THE CURB OR BARRIER.

sour
ces bel
i
eved t
o be r
el
i
abl
e. PCINor
t
heastori
t
s m em ber
shi
ps shal
lnotbe r
esponsi
bl
ef
orany er
r
or
s,om i
ssi
on

WEARING SURFACE

The det
ai
l
s shown ar
e gui
del
i
nes and shoul
d notbe consi
der
ed st
andar
ds. The i
nf
or
m at
i
on has been obt
ai
ned f
r
om

8" MINIMUM
INTEGRAL DECK/TOP FLANGE

PRECAST/
PRESTRESSED CONCRETE I
NSTI
TUTE NORTHEAST

1. THE DETAILS SHOWN DEPICT VARYING THE THICKNESS OF THE TOP


FLANGE. ANOTHER OPTION IS TO VERY THE THICKNESS OF THE OVERLAY.
NOTE THAT THE HEIGHT OF THE CURB OR PARAPET WILL STILL VARY.

t
hr
ough t
hi
s gui
del
i
ne. I
fsuch ser
vi
ces ar
er
equi
r
ed,pl
ease seek an appr
opr
i
at
e pr
of
essi
onal
.

WWW.
PCI
NE.
ORG

NOTES

1
1

2. THE WELDED WIRE FABRIC MAY BE CUT TO FACILITATE THE INSTALLATION AROUND THE STIRRUPS, PROVIDED THAT EQUIVALENT BARS ARE ADDED
ADJACENT TO THE CUT FABRIC. EQUIVALENT MILD REINFORCEMENT MAY ALSO BE USED IN PLACE OF THE WWF, PROVIDED THAT THE SPACING OF
THE BARS DOES NOT EXCEED 12 INCHES. ON A PRELIMINARY DESIGN OF A NEXT BEAM WITH AN 8 INCH THICK DECK. DESIGNERS SHOULD
VERIFY THIS REINFORCING FOR EACH DESIGN BASED ON THE ACTUAL DECK THICKNESS.

PCI

3. THE ADDITIONAL TOP STEEL IN THE BEAM OVERHANGS SHOULD ONLY BE USED WHERE THE WELDED WIRE FABRIC CANNOT SUPPORT THE
OVERHANG LOADS.

TM

4. SHEAR REINFORCING SHOULD BE KEPT TO #4 BARS IN ORDER TO MAXIMIZE THE COVER ON THE SIDE OF THE STEM.
#4 STIRRUPS (TYP)
5. SEE SHEET 14 FOR UTILITIES SUPPORT DETAILS.
2 STRANDS AT TOP
OF EACH STEM
0"
NEXT E NOTES:
1. THE TOP FLANGE IS INTENDED TO ACT AS THE BOTTOM PORTION OF THE DECK. A REINFORCED CAST-IN-PLACE CONCRETE TOPPING
SHOULD BE DESIGNED TO COMPLETE THE STRUCTURAL DECK. THE REINFORCING SHOWN IS BASED ON A PRELIMINARY DESIGN OF A
NEXT BEAM WITH AN 8 INCH THICK DECK. DESIGNERS SHOULD VERIFY THIS REINFORCING FOR EACH DESIGN BASED ON THE
ACTUAL DECK THICKNESS.

2. SHEAR REINFORCING SHOULD BE KEPT TO #4 BARS IN ORDER TO MAXIMIZE THE COVER ON THE SIDE OF THE STEM.
3. SEE SHEET 14 FOR UTILITY SUPPORT DETAILS.
4. MINOR ADJUSTMENT OF THE SPACING OF THE TOP LONGITUDINAL REINFORCEMENT IS ALLOWABLE TO FACILITATE THE
INSTALLATION OF THE STIRRUPS.

2"+

DESIGN NOTES
#4 STIRRUPS (TYP)

2 STRANDS AT TOP
OF EACH STEM

1. THE REINFORCING SHOWN IS PRELIMINARY AND NOT GUARANTEED. DESIGNERS MUST VERIFY THE REINFORCING FOR EACH DESIGN BASED ON THE
AASHTO LRFD BRIDGE DESIGN SPECIFICATIONS OR STATE STANDARDS.
2. THE STRIP METHOD SPECIFIED IN AASHTO LRFD ARTICLE 4.6.2.1 IS RECOMMENDED FOR THE DESIGN OF THE REINFORCING IN THE NEXT E
AND D BEAMS.

0"
1" COVER WITH
#4 STIRRUP (TYP)

3. THE REINFORCING BARS EXTENSIONS SHOWN IN THE NEXT E AND D BEAMS SHOULD BE DESIGNED TO RESIST THE POSITIVE BENDING MOMENT
AT THE CENTER OF THE JOINT AS DETERMINED BY THE AASHTO STRIP METHOD OF DECK DESIGN. THE NESTED HOOKED BARS CAN BE
CONSIDERED A LAP SPLICE WITH THE BARS FULLY DEVELOPED. THE CRACK CONTROL PROVISIONS OF AASHTO ARTICLE 5.7.3.4. SHOULD
ALSO BE CHECKED FOR THESE BARS.

4 SP @ 2" (TYP)

4. ADDITIONAL REINFORCEMENT MAY BE REQUIRED FOR DECK OVERHANGS AND BARRIERS.

4 SP @ 2" = 8" (TYP)

#5 J BAR (20"x10") END ZONE REINFORCING (TYP)


6" INSIDE RADIUS OR EQUIVALENT MULTIPLE BENDS
DOUBLE BARS SHOWN MAY BE COMBINED INTO ONE
INVERTED U SHAPED BAR.
SEE SHEET 09 FOR DETAILS

2" (TYP)

NEXT E BEAM

#4 HOOKED REINFORCING BAR


MIN. COVER ALLOWED BY AGENCY
6" ON CENTER (TYP)
1" RECOMMENDED
8"

2 "

1 "

#4@9" TOP AND BOTTOM (TYP)


90 HOOK

STRAND LAYOUT NOTES


1. DENOTES STRAIGHT STRAND. DRAPED STRANDS ARE NOT PERMITTED.
2. DEBONDING OF STRAND IS ALLOWED. NO MORE THAN 25% OF THE TOTAL NUMBER OF STRANDS SHALL BE DEBONDED. THE SPACING BETWEEN
DEBONDED STRANDS SHALL BE AT LEAST 2.5 INCHES IN ANY DIRECTION. THE RESTRICTIONS OUTLINED IN THE AASHTO LRFD BRIDGE
DESIGN SPECIFICATIONS SHALL ALSO BE FOLLOWED.
3. IT IS RECOMMENDED THAT APPROXIMATELY 50% OF ALL STRAND BE DEBONDED FOR THE FIRST 6" FROM THE END OF THE BEAM IN ORDER
TO CONTROL END CRACKING. SPACING RESTRICTIONS OUTLINED IN NOTE 2 DO NOT APPLY TO THIS 6" AREA, BUT DO APPLY BEYOND
THIS 6" AREA.

2"

(TYP)

#4@6" TOP AND BOTTOM

DECK FINISH

5. THE DESIGNER SHALL DETAIL ADDITIONAL TOP LONGITUDINAL REINFORCING IN THE TOP FLANGE AT BEAM ENDS IF THE TOP FIBER
STRESSES EXCEED 200 PSI. THESE BARS ARE USED TO CONTROL TRANSVERSE CRACKING IN THE TOP FLANGE AT RELEASE. THIS
REINFORCING SHALL BE DESIGNED IN ACCORDANCE WITH THE AASHTO LRFD BRIDGE DESIGN SPECIFICATIONS. THIS REINFORCING IS FOR
CRACK WIDTH AND LENGTH CONTROL, NOT PREVENTION. IT IS RECOMMENDED THAT IF FULLY TENSIONED TOP STRAND ARE INCLUDED
IN THE DESIGN, THEY SHOULD NOT BE USED TO MEET THESE AASHTO PROVISIONS, SINCE THEY ARE ALREADY BEING USED TO CONTROL
STRESS IN THE BEAM.

#4 STIRRUPS (TYP)

4. STRANDS SHALL BE PLACED WITHIN THE 2"x2" GRID. THE PATTERN MAY BE RAISED IN 2" INCREMENTS FOR DESIGNS THAT REQUIRE
PRESTRESS AT A HIGHER ELEVATION. THE NUMBER AND LOCATION OF STRANDS SHALL BE AS REQUIRED BY DESIGN.

2 STRANDS AT TOP
OF EACH STEM

0"

1" COVER WITH


#4 STIRRUP (TYP)

5. THE PATTERN SHOWN DEPICTS THE MAXIMUM NUMBER OF STRANDS ALLOWED (50 STRAND INCLUDING THE TOP STRAND). THIS IS BASED
ON THE CAPACITY OF TYPICAL CASTING BEDS.
6. THE TWO BOTTOM CORNER STRAND IN EACH STEM ARE OMITTED TO PROVIDE ROOM FOR THE SHEAR REINFORCEMENT BAR BENDS.

4 SP @ 2" (TYP)

7. ALL PRESTRESSING STRAND SHALL BE 0.6" DIAMETER, UNCOATED SEVEN WIRE, LOW RELAXATION STRANDS CONFORMING TO AASHTO M203.
THE ULTIMATE STRENGTH OF THE STRANDS SHALL BE 270 KSI.
OPTIONAL #5 J BAR (20"x10") END ZONE REINFORCING (TYP)
6" INSIDE RADIUS OR EQUIVALENT MULTIPLE BENDS
DOUBLE BARS SHOWN MAY BE COMBINED INTO ONE
INVERTED U SHAPED BAR.
SEE SHEET 10 FOR DETAILS

8. ADDITIONAL STRAND TENSIONED TO A NOMINAL VALUE MAY BE ADDED TO THE TOP FLANGE TO SUPPORT THE TOP FLANGE REINFORCING.

DATE

2" (TYP)

NEXT D BEAM
NO.

4 SP @ 2" = 8" (TYP)

I
SSUE DATE: 03 / 10 / 15

RAKE FINISH

SHEET:NEXT 05

BOTTOM TRANSVERSE DECK


REINFORCING (TYP)
6" SPACING RECOMMENDED

MIN. COVER ALLOWED BY AGENCY


1" RECOMMENDED

LOCATI
ON OF TOP STRAND & REI
NF.OF NEXT F

1" (TYP)

01 /2016

t
hr
ough t
hi
s gui
del
i
ne. I
fsuch ser
vi
ces ar
er
equi
r
ed,pl
ease seek an appr
opr
i
at
e pr
of
essi
onal
.

1. THE TOP FLANGE IS INTENDED TO ACT AS A STRUCTURAL DECK.

EXTEND STIRRUPS TO PROVIDE


HORIZONTAL SHEAR RESISTANCE
(TYP)

DI
SCLAI
M ER:

NEXT D NOTES:
HOOKED BAR CONNECTOR
SEE DETAILS, SHEET 9

- TYPI
CAL BEAM

NEXT F BEAM

NEXT BEAM

4. SEE SHEET 14 FOR UTILITIES SUPPORT DETAILS.

REI
NFORCI
NG

3. SHEAR REINFORCING SHOULD BE KEPT TO #4 BARS IN ORDER TO MAXIMIZE THE COVER ON THE SIDE OF THE STEM.

NORTHEAST EXTREM E TEE (


NEXT)BEAM DETAI
LS

2" (TYP)

2. THE DESIGN OF THE DECK REINFORCING SHOULD BE BASED ON A CONVENTIONAL CAST-IN-PLACE CONCRETE DECK ASSUMING THAT
THE STEMS ARE INDIVIDUAL BEAMS.

REVI
SI
ONS

4 SP @ 2" = 8" (TYP)

#5 J BAR (20"x10") END ZONE REINFORCING (TYP)


6" INSIDE RADIUS OR EQUIVALENT MULTIPLE BENDS.
DOUBLE BARS SHOWN MAY BE COMBINED INTO ONE
INVERTED U SHAPED BAR.
SEE SHEET 08 FOR DETAILS

DESCRI
PTI
ON

4 SP @ 2" (TYP)

Nor
t
heasti
s suppl
yi
ng i
nf
or
m at
i
on onl
y. PCINor
t
heasti
s notr
ender
i
ng engi
neer
i
ng orot
herpr
of
essi
onalser
vi
ces

1" COVER WITH


#4 STIRRUP (TYP)

ordam ages ar
i
si
ng outoft
hi
si
nf
or
m at
i
on. PCINor
t
heasthas publ
i
shed t
hi
s wor
k wi
t
ht
he under
st
andi
ng t
hatPCI

4x4 W4xW4 WWF PLACED AT MID-DEPTH


OF TOP FLANGE (SEE NOTE 2)

sour
ces bel
i
eved t
o be r
el
i
abl
e. PCINor
t
heastori
t
s m em ber
shi
ps shal
lnotbe r
esponsi
bl
ef
orany er
r
or
s,om i
ssi
on

RAKE FINISH

1. THE TOP FLANGE IS INTENDED TO ACT AS A DECK FORM ONLY. A REINFORCED CAST-IN-PLACE CONCRETE DECK SHOULD BE DESIGNED TO SPAN
BETWEEN STEMS. THE WELDED WIRE FABRIC SHOWN IS USED TO SUPPORT THE WET DECK CONCRETE ONLY. THE REINFORCING SHOWN IS BASE

The det
ai
l
s shown ar
e gui
del
i
nes and shoul
d notbe consi
der
ed st
andar
ds. The i
nf
or
m at
i
on has been obt
ai
ned f
r
om

1 1" (TYP)

PRECAST/
PRESTRESSED CONCRETE I
NSTI
TUTE NORTHEAST

NEXT F NOTES:
ADDITIONAL REINFORCING FOR
OVERHANG LOADS (TYP) EXTEND
BARS TO CENTER OF BEAM
(USE WWF IF POSSIBLE)

MIN. COVER ALLOWED BY AGENCY


1" RECOMMENDED

4"+

WWW.
PCI
NE.
ORG

GENERAL NOTES

EXTEND STIRRUPS TO PROVIDE


HORIZONTAL SHEAR RESISTANCE
(TYP)

BEAM
DESIGNATION

A/2

BEAM
WIDTH
INCHES

BEAM
DEPTH
INCHES
B

AREA
IN

I
IN

Yb

Yt

St

INCHES

INCHES

IN

Sb
3

WEIGHT
3

IN

PLF

RAKE FINISH
1'-3"

TM

Yt

1'-3"

PCI

4"

BASE STEM
WIDTH
INCHES

C.G.

R=4" (TYP)
B

" DRAFT ON EDGE

Yb

12

0.375

PRECAST/
PRESTRESSED CONCRETE I
NSTI
TUTE NORTHEAST

NEXT BEAM - SECTION PROPERTIES

DIMENSION A (MINIMUM 7'-11") FOR 8'-0" BEAM SPACING


A/2

WWW.
PCI
NE.
ORG

DIMENSION A (MAXIMUM 11'-11") FOR 12'-0" BEAM SPACING

5'-0"

" DRAFT WITH "


CHAMFER ON FASCIA EDGE
Yb

12

0.375

BEAM DIMENSION NOTES

5'-0"
" CHAMFER (TYP)
C

ALL NEXT BEAM TYPES:

C
1. THE WIDTH OF BEAMS SHOWN ARE THE MINIMUM AND MAXIMUM WIDTH BEAMS. VARIATION BETWEEN
THESE LIMITS IS ALLOWED IN ORDER TO CONSTRUCT A BRIDGE TO THE REQUIRED WIDTH. THE
VARIATION IN WIDTH IS ACCOMPLISHED BY VARYING THE OVERHANG DIMENSIONS. THE DESIGNER
WILL NEED TO CALCULATE BEAM PROPERTIES FOR BEAMS THAT ARE NOT EQUAL TO THE WIDTHS LISTED.

NEXT E BEAM

DIMENSION A (MAXIMUM 10'-0") FOR 10'-9" BEAM SPACING

2. BRIDGES WITH SMALL CURVATURE CAN BE BUILT USING THESE SECTIONS BY VARYING THE
OVERHANG OF THE FASCIA BEAMS ALONG THE LENGTH. INTERIOR BEAMS SHOULD ALWAYS BE
SYMMETRICAL ABOUT THE VERTICAL AXIS. NON-SYMMETRICAL SECTIONS ARE POSSIBLE, HOWEVER THE
BEAM MAY REQUIRE A SPECIAL DESIGN WITH A NON-SYMMETRICAL STRAND PATTERN.

DIMENSION A (MINIMUM 8'-0") FOR 8'-9" BEAM SPACING

3. THE STEM WIDTH AND SPACING ARE FIXED.

A/2

A/2

4. THE ENDS OF THE BEAMS SHOULD BE SKEWED FOR SKEWED BRIDGES. THE ACUTE CORNERS OF THE
FLANGE OVERHANGS SHOULD BE CHAMFERED 6"x6" IN ORDER TO MINIMIZE CASTING AND HANDLING DAMAGE.

DECK FINISH
1'-3"

1'-3"

t
hr
ough t
hi
s gui
del
i
ne. I
fsuch ser
vi
ces ar
er
equi
r
ed,pl
ease seek an appr
opr
i
at
e pr
of
essi
onal
.

C.G.

R=4" (TYP)

Nor
t
heasti
s suppl
yi
ng i
nf
or
m at
i
on onl
y. PCINor
t
heasti
s notr
ender
i
ng engi
neer
i
ng orot
herpr
of
essi
onalser
vi
ces

Yt

FASCIA EDGES

ordam ages ar
i
si
ng outoft
hi
si
nf
or
m at
i
on. PCINor
t
heasthas publ
i
shed t
hi
s wor
k wi
t
ht
he under
st
andi
ng t
hatPCI

RAKE FINISH
1'-3"

4"

1'-3"

INTERIOR EDGES

A/2

The det
ai
l
s shown ar
e gui
del
i
nes and shoul
d notbe consi
der
ed st
andar
ds. The i
nf
or
m at
i
on has been obt
ai
ned f
r
om

A/2

DI
SCLAI
M ER:

DIMENSION A (MINIMUM 8'-0") FOR 9'-4" BEAM SPACING

- SECTI
ON PROPERTI
ES

DIMENSION A (MAXIMUM 9'-6") FOR 10'-10" BEAM SPACING

NEXT BEAM

NEXT F BEAM

NORTHEAST EXTREM E TEE (


NEXT)BEAM DETAI
LS

sour
ces bel
i
eved t
o be r
el
i
abl
e. PCINor
t
heastori
t
s m em ber
shi
ps shal
lnotbe r
esponsi
bl
ef
orany er
r
or
s,om i
ssi
on

" CHAMFER (TYP)


C

Yb

5'-0"

" CHAMFER (TYP)

NEXT D BEAM

DATE

NO.

0.375

I
SSUE DATE: 03 / 10 / 15

1. THE ACTUAL WIDTH OF THE BEAM TAKE INTO ACCOUNT A NOMINAL " WIDE GAP BETWEEN BEAMS TO
ACCOUNT FOR TOLERANCES. THE SPACING OF BEAMS ON A TYPICAL BRIDGE SHALL BE AT THE NOMINAL
SPACING (EX.: BEAM SPACING = 12 FEET FOR THE 11'-11" SECTION).

12

SHEET: NEXT 06

NEXT F BEAMS:

C.G.

R=4" (TYP)

REVI
SI
ONS

2. MODIFY THE FASCIA BEAM DECK EDGE TO MATCH STATE STANDARDS.

DESCRI
PTI
ON

1. THE SPACING OF BEAMS ON A TYPICAL BRIDGE SHALL BE THE WIDTH OF THE BEAM PLUS 9"
(EX.: BEAM SPACING = 10'-9" FOR THE 10'-0" SECTION).

Yt

8"

NEXT D BEAMS:

12'-0" LANE

12'-0" LANE
ROADWAY BASELINE

8" MIN. REINFORCED


CONCRETE DECK

BRIDGE SECTION NOTES


1'-7"

WEARING SURFACE
SEE DETAIL BELOW

1. THE TWO BRIDGE SECTIONS DEPICTED REPRESENT THE TYPICAL USE OF THE MINIMUM
WIDTH AND MAXIMUM WIDTH NEXT BEAMS.

12'-0"

12'-0"

5'-11"

NEXT F BEAMS - MAXIMUM WIDTH BEAMS

4. OFFSET THE BEARING SUPPORT LOCATIONS FROM THE ROADWAY BASELINE ACCOUNTING FOR
THE CROSS SLOPE AND ROTATION OF THE BEAMS RELATIVE TO THE LONGITUDINAL AXIS OF THE
BEAM. THE DIMENSIONS OF ALL BEARING LOCATIONS ON THE PLANS SHOULD ACCOUNT FOR
THIS ROTATIONAL OFFSET.

28'-9"
12'-0" LANE

12'-0" LANE

8" MIN. REINFORCED


CONCRETE DECK

2'-4"

3'-11"

SEE NOTE 4

NEXT F BEAMS - MINIMUM WIDTH BEAMS

31'-6"
31'-4"

1'-7"

12'-0" LANE

12'-0" LANE

2'-1"

2'-"
1'-7"

4" MINIMUM REINFORCED


CONCRETE DECK

12'-0" LANE

2'-"
1'-7"

WEARING SURFACE
SEE JOINT DETAILS
SHEET 04

SEE NOTE 4
4'-9"

12'-0" LANE

1'-7"

10'-10"

WEARING SURFACE

DI
SCLAI
M ER:

2'-1"

SEE NOTE 4

10'-10"

4'-9"

5'-0"

NEXT E BEAMS - MAXIMUM WIDTH BEAMS

10'-9"

10'-9"

NEXT 07

8'-0"

t
hr
ough t
hi
s gui
del
i
ne. I
fsuch ser
vi
ces ar
er
equi
r
ed,pl
ease seek an appr
opr
i
at
e pr
of
essi
onal
.

8'-0"

- SECTI
ON PROPERTI
ES

8'-0"

NEXT BEAM

3'-11"

NORTHEAST EXTREM E TEE (


NEXT)BEAM DETAI
LS

Nor
t
heasti
s suppl
yi
ng i
nf
or
m at
i
on onl
y. PCINor
t
heasti
s notr
ender
i
ng engi
neer
i
ng orot
herpr
of
essi
onalser
vi
ces

1'-7"

WEARING SURFACE

SEE GAP DETAIL

ordam ages ar
i
si
ng outoft
hi
si
nf
or
m at
i
on. PCINor
t
heasthas publ
i
shed t
hi
s wor
k wi
t
ht
he under
st
andi
ng t
hatPCI

ROADWAY BASELINE

1'-7"

sour
ces bel
i
eved t
o be r
el
i
abl
e. PCINor
t
heastori
t
s m em ber
shi
ps shal
lnotbe r
esponsi
bl
ef
orany er
r
or
s,om i
ssi
on

2'-4"

TM

3. IN SPECIAL CASES, A HALF WIDTH BEAM SECTION CAN BE USED TO ACCOMODATE UNUSUAL
BRIDGE WIDTHS. SPECIAL TEMPORARY BRACING WILL BE REQUIRED FOR SHIPPING AND
ERECTION. THIS OPTION SHOULD ONLY BE USED IN SPECIAL SITUATIONS AND WITH APPROVAL
FROM THE OWNER. IN LIEU OF THIS OPTION, THE DESIGNER CAN CONSIDER THE USE OF WIDER
OR NARROWER BEAMS WITHIN THE LIMITS OF THE BEAM FORMS. (12' MAXIMUM CONCRETE
SECTION). THIS OPTION MAY REQUIRE SPECIAL SHIPPING CONSIDERATIONS, WHICH WILL LEAD
TO AN INCREASE IN SHIPPING COSTS.

SEE NOTE 4
5'-11"

PCI

2. THESE SECTIONS WERE USED TO DEVELOP THE BEAM SPAN TABLES DEPICTED WITHIN
THESE SHEETS. THE SPAN TABLES ARE FOR THREE DIFFERENT CONCRETE STRENGTHS;
f'c = 10 KSI, 8 KSI, AND 6 KSI. THE SPAN TABLES ARE FOR REFERENCE ONLY. ALTERNATE
BRIDGE CONFIGURATIONS WITH DIFFERENT PARAPETS AND OVERLAYS WILL RESULT IN
DIFFERENT MAXIMUM SPAN LENGTHS AND STRANDS.

The det
ai
l
s shown ar
e gui
del
i
nes and shoul
d notbe consi
der
ed st
andar
ds. The i
nf
or
m at
i
on has been obt
ai
ned f
r
om

1'-7"

4'-4"

PRECAST/
PRESTRESSED CONCRETE I
NSTI
TUTE NORTHEAST

WWW.
PCI
NE.
ORG

32'-9"
4'-4"

5'-0"

NEXT D BEAMS - MAXIMUM WIDTH BEAMS

33'-11"
36'-2"
3'-4"

4'-0"

SEE NOTE 4
3'-11"

9'-4"

9'-4"

NEXT E BEAMS - MINIMUM WIDTH BEAMS

9'-4"

3'-11"

8'-9"

8'-9"

8'-9"

4'-0"

SEE NOTE 4

NEXT D BEAMS - MINIMUM WIDTH BEAMS

I
SSUE DATE: 03 / 10 / 15

WEARING SURFACE

SHEET: NEXT 07

SEE JOINT DETAILS


SHEET 04

10 /2015

1'-7"

CHANGED RAI
LI
NG TO CONCRETE BARRI
ER

1'-7"

WEARING SURFACE

4" MINIMUM REINFORCED


CONCRETE DECK

3'-4"

1'-7"

12'-0" LANE

1'-7"

REVI
SI
ONS

4'-5"

DESCRI
PTI
ON

12'-0" LANE

DATE

12'-0" LANE

NO.

4'-5"

12'-0" LANE

REINFORCED CONCRETE DECK

NOTE: NORMAL TOP FLANGE REINFORCEMENT NOT SHOWN

FILL VOID WITH


NON-SHRINK GROUT

J BARS MAY BE PLACED NORMAL TO STEM


OPPOSING J BARS MAY BE COMBINED INTO ONE
INVERTED U SHAPED BAR

NOTE: h = TOTAL HEIGHT OF MEMBER

LOOP DOWEL (TYP)

PLAN - SKEWED END

NORMAL PARAPET
REINFORCING (TYP)

PLAN
WATERPROOFING MEMBRANE CURB
DETAILS AS PER STATE STANDARDS
JOINT SEAL
#4 BARS PLACED AT MID DEPTH
OF TOP FLANGE. SEE NOTE 3

PRECAST CONCRETE CURB


SECTION WITH BARS PROJECTING
INTO THE DECK SLAB

MEMBRANE WATERPROOFING
STIRRUPS MAY BE BUNDLED IN
END ZONE IF REQUIRED

CAST DECK AFTER CURB PLACEMENT


WEARING SURFACE

COVER

0"

1"

SUPPLEMENTAL FLANGE
REINFORCING.

OVERHANG (IF DESIRED)


BLOCKOUT (SEE
STATE STANDARDS)

PLACE CURB IN GROUT BED

TRANSVERSE DECK REINFORCING

DRIP EDGE

STANDARD STIRRUP

ANCHOR REAR FACE VERTICALS IN MIDDLE OF STRAND GRID

3. PLACE 2-#4 BARS AT THE BEAM END, THEN #4 @ 6 INCHES IN THE TOP FLANGE TO CONTROL TOP FLANGE END CRACKING
DURING RELEASE AND HANDLING. THE MOST COMMON FORM OF POTENTIAL CRACKING IN THIS AREA IS A SERIES OF VERTICAL
HAIRLINE CRACKS THROUGH THE INSIDE RADIUS OF THE TOP FLANGE / BEAM STEM INTERFACE RUNNING PARALLEL TO THE STEM.
#5 J BARS ARE USED TO SUPPLEMENT THIS REINFORCING. THE TWO J SHAPED BARS SHOWN MAY BE COMBINED INTO ONE
INVERTED U SHAPED BAR.THE USE OF A SEMI-INTEGRAL BACKWALL THAT IS CAST IN THE SHOP AS A SECONDARY POUR CAN
HELP TO PREVENT THE GROWTH OF THESE CRACKS DURING SHIPPING AND ERECTION.
4. THE DESIGNER SHALL DETAIL ADDITIONAL TOP LONGITUDINAL REINFORCING IN THE TOP FLANGE AT BEAM ENDS IF THE TOP FIBER
STRESSES EXCEED 200 PSI. THESE BARS ARE USED TO CONTROL TRANSVERSE CRACKING IN THE TOP FLANGE AT RELEASE. THIS
REINFORCING SHALL BE DESIGNED IN ACCORDANCE WITH THE AASHTO LRFD BRIDGE DESIGN SPECIFICATIONS. THIS REINFORCING
IS FOR CRACK WIDTH AND LENGTH CONTROL, NOT PREVENTION. IF FULLY TENSIONED TOP STRAND ARE INCLUDED IN THE DESIGN,
THEY SHOULD NOT BE USED TO MEET THESE AASHTO PROVISIONS.

NEXT F BEAM - PRECAST PARAPET OPTIONS


CONSTRUCTION SEQUENCE
1. ERECT NEXT BEAM
2. PLACE PRECAST PARAPET IN GROUT BED, GROUT JOINTS IN PARAPET
3. PLACE DECK REINFORCEMENT AND CAST THE DECK OVERPOUR
4. SEAL THE JOINT BETWEEN THE PARAPET AND DECK WITH FLEXIBLE JOINT SEAL
5. PLACE WEARING SURFACE (IF REQUIRED)

NOTES: THIS DETAIL IS SCHEMATIC. ACTUAL DETAIL WOULD NEED TO BE FULLY DESIGNED.
STEEL RAIL IN CURB SHOWN, OTHER PARAPETS SIMILAR.
THIS DETAIL CAN BE MODIFIED FOR ANY TYPICAL PARAPET SHAPE INCLUDING F SHAPE PARAPETS.
ANCHOR BOLTS NOT SHOWN IN CURB.
ALL REINFORCING IN BEAM AND DECK POUR NOT SHOWN.
STIRRUP SPACING MAY NEED TO BE MODIFIED IF ONE LEG OF STIRRUP IS ELIMINATED IN ORDER TO
ALLOW SETTING OF PRECAST CURB/BARRIER.
CAST-IN-PLACE CONCRETE BARRIERS MAY ALSO BE USED WITH SIMILAR DETAILS.

CHANGED RAI
LI
NG TO CONCRETE BARRI
ER

2. THE AMOUNT OF SPLITTING REINFORCING MAY BE REDUCED BY DEBONDING STRAND IN THIS AREA. ADDITIONAL SPLITTING
REINFORCING SHOULD BE PLACED IN AREAS WHERE DEBONDING IS TERMINATED.

SECTION

10 /2015

1. THE BARS SHOWN ARE APPROXIMATELY THE MAXIMUM NUMBER THAT CAN BE FIT WITHIN THE NEXT 24 BEAM. SOME OR ALL
OF THESE ADDITIONAL END VERTICAL BARS MAY NOT BE NECESSARY DEPENDING ON THE DESIGN.

NEXT F BEAM - END REINFORCING DETAILS

REVI
SI
ONS

NOTES:

DESCRI
PTI
ON

END ELEVATION - STEM END

NEXT BEAM

ELEVATION - STEM END

DATE

ADDITIONAL END ZONE


VERTICALS
#4

NO.

ADDITIONAL END ZONE


VERTICALS
#4

I
SSUE DATE: 03 / 10 / 15

SHEAR REINFORCEMENT USED FOR


BURSTING STEEL IN END ZONE

BARS PROJECTING FROM PRECAST


CURB INTO DECK SLAB OVERPOUR

SHEET:NEXT 08

BURSTING ZONE = h/4


(AASHTO LRFD 5.10.10.1)

The det
ai
l
s shown ar
e gui
del
i
nes and shoul
d notbe consi
der
ed st
andar
ds. The i
nf
or
m at
i
on has been obt
ai
ned f
r
om

FOAM BACKER ROD (TYP)


1.5xh

DI
SCLAI
M ER:

BURSTING ZONE VERTICAL REINFORCING


SEE NOTE 1

- DECK DETAI
LS

#5 DOWEL
4"x4" KEYWAY (TYP)

NEXT F BEAM

RECOMMENDED 20 DEGREES MAX.


BEAMS WITH HIGHER SKEWS ARE
STRONGLY DISCOURAGED DUE TO POTENTIAL
FOR CRACKING IN THE TOP FLANGE DURING
FABRICATION AND HANDLING

NORTHEAST EXTREM E TEE (


NEXT)BEAM DETAI
LS

#5 L BAR (20"X10")
20 SPACES @ 6"=10'
PLACE IN BOTH STEMS

Nor
t
heasti
s suppl
yi
ng i
nf
or
m at
i
on onl
y. PCINor
t
heasti
s notr
ender
i
ng engi
neer
i
ng orot
herpr
of
essi
onalser
vi
ces

NEXT F BEAM - GAP FORM DETAIL


#4 BARS PLACED AT
MID-DEPTH OF TOP
FLANGE. SEE NOTE 3

ordam ages ar
i
si
ng outoft
hi
si
nf
or
m at
i
on. PCINor
t
heasthas publ
i
shed t
hi
s wor
k wi
t
ht
he under
st
andi
ng t
hatPCI

DIFFERENTIAL CAMBER
TOP FLANGE OF NEXT BEAM

sour
ces bel
i
eved t
o be r
el
i
abl
e. PCINor
t
heastori
t
s m em ber
shi
ps shal
lnotbe r
esponsi
bl
ef
orany er
r
or
s,om i
ssi
on

TM

NOTE: DESIGNERS SHOULD


CONSULT WITH SEVERAL
FABRICATORS FOR LONG SPAN
SKEWED BEAMS REGARDING
POTENTIAL SHIPPING LIMITATIONS.

PCI

SEAL MATERIAL AS REQUIRED

PRECAST/
PRESTRESSED CONCRETE I
NSTI
TUTE NORTHEAST

"+ " TOLERANCE

t
hr
ough t
hi
s gui
del
i
ne. I
fsuch ser
vi
ces ar
er
equi
r
ed,pl
ease seek an appr
opr
i
at
e pr
of
essi
onal
.

WWW.
PCI
NE.
ORG

NORMAL SHEAR REINFORCEMENT

SECTION

#4 REINFORCING BAR WITH 180 HOOK (TYP)

SPLICE PROJECTING HOOK BARS


WITH MAIN DECK REINFORCING
21" MINIMUM LAP SPLICE (TYP)

6"

TRANSVERSE #4 DECK BARS,


2 AT BEAM END, THEN #4@6".
SPLAY IN ACUTE END REGION (TYP)

DISCONTINUE BARS WHEN SPACING


TO ADJACENT BAR IS LESS THAN 3" (TYP)

NEXT E BEAM - FLANGE CONNECTION DETAILS


PLAN

NEXT E BEAM - MAIN DECK REINFORCING DETAILS


SKEWED BEAM ENDS

NOTE: h = TOTAL HEIGHT OF MEMBER


BURSTING ZONE = h/4
(AASHTO LRFD 5.10.10.1)

SHEAR REINFORCEMENT USED FOR


BURSTING STEEL IN END ZONE
#5 L BAR (20"X10")
20 SPACES @ 6"=10'
PLACE IN BOTH STEMS

WATERPROOFING MEMBRANE CURB


DETAILS AS PER STATE STANDARDS
JOINT SEAL

STIRRUPS MAY BE BUNDLED IN


END ZONE IF REQUIRED

COVER

0"

1"

MEMBRANE WATERPROOFING
WEARING SURFACE
BLOCKOUT (SEE
STATE STANDARDS)

ADDITIONAL END ZONE


VERTICALS
#4

ADDITIONAL END ZONE


VERTICALS
#4

STANDARD STIRRUP

TM

DI
SCLAI
M ER:

PLAN

- DECK DETAI
LS

1. USE THIS DETAIL FOR ALL SKEWED BEAMS.


2. OTHER REINFORCING BARS SUCH AS END ZONE REINFORCING
NOT SHOWN FOR CLARITY. SIMILAR TO NEXT F BEAMS.
3. THE BAR LAYOUT SHOWN IS APPROXIMATE. THE
FABRICATOR SHALL LAY OUT BARS TO PROVIDE A MAXIMUM
OF 6" SPACING BETWEEN ADJACENT TRANSVERSE DECK BARS.

NEXT E BEAM

NOTES:

NORTHEAST EXTREM E TEE (


NEXT)BEAM DETAI
LS

6"

RECOMMENDED 20 DEGREES MAX.


BEAMS WITH HIGHER SKEWS ARE
STRONGLY DISCOURAGED DUE TO POTENTIAL
FOR CRACKING IN THE TOP FLANGE DURING
FABRICATION AND HANDLING

Nor
t
heasti
s suppl
yi
ng i
nf
or
m at
i
on onl
y. PCINor
t
heasti
s notr
ender
i
ng engi
neer
i
ng orot
herpr
of
essi
onalser
vi
ces

4-#4

1" BOTTOM COVER

ordam ages ar
i
si
ng outoft
hi
si
nf
or
m at
i
on. PCINor
t
heasthas publ
i
shed t
hi
s wor
k wi
t
ht
he under
st
andi
ng t
hatPCI

1"x1" CHAMFER (TYP.)

sour
ces bel
i
eved t
o be r
el
i
abl
e. PCINor
t
heastori
t
s m em ber
shi
ps shal
lnotbe r
esponsi
bl
ef
orany er
r
or
s,om i
ssi
on

MIN.

DETAIL BASED ON:


f'c = 4 ksi
fy = 60 ksi
EPOXY COATED
#4 BAR
As req/As prov = 1

PCI

1. CONNECTOR REINFORCING TO BE PLACED ALONG THE ENTIRE


SPAN WITH 6" SPACING.
2. FOR SKEWED BRIDGES, PLACE CONNECTOR REINFORCING
PERPENDICULAR TO BEAM EDGE. BEND CONNECTOR REINFORCING
WITHIN THE FLANGE IN ACUTE CORNERS TO PRODUCE A SQUARE
PROJECTION.
3. METHOD OF FORMING CLOSURE POUR TO BE DETERMINED BY THE
CONTRACTOR. THE FORMS NEEDS TO BE REMOVABLE AND ABLE TO
ACCOMMODATE DIFFERENTIAL CAMBER. FORM SUPPORTS SHOULD
NOT PENETRATE THROUGH TOP OF POUR UNLESS APPROVED BY THE
ENGINEER. GALVANIZED OR STAINLESS STEEL INSERTS CAST INTO
THE UNDERSIDE OF THE BEAM MAY BE USED WITH PERMISSION OF
THE OWNER.
4. DESIGNERS ARE RESPONSIBLE FOR THE VERIFICATION OF THE DESIGN
OF THIS JOINT. THE BASIS OF THE DESIGN IS THAT THE MINIMUM
DEVELOPMENT LENGTH AS SPECIFIED IN AASHTO FOR HOOKED BARS
IS EQUIVALENT TO A TENSION LAP SPLICE.
5. THE DIMENSION SHOWN IS APPLICABLE TO A DESIGN WITH THE
PARAMETERS LISTED. THE MINIMUM LAP LENGTH SHALL BE INCREASED
BY 1" TO ACCOUNT FOR FABRICATION AND ERECTION TOLERANCES.
6. #4 BARS ARE REQUIRED TO PROVIDE THE MINIMUM CONCRETE
BOTTOM SHOWN. IF LARGER BARS ARE USED, A THICKER TOPPING
POUR WILL BE REQUIRED IN ORDER TO ACCOMMODATE THE HOOK
DIMENSIONS.

PRECAST/
PRESTRESSED CONCRETE I
NSTI
TUTE NORTHEAST

FLANGE CONNECTOR NOTES:

#4 @ 6"

NEXT BEAM TOP


FLANGE

PROJECTING HOOK BAR (TYP)


BEND PROJECTING HOOK BARS JUST
INSIDE FACE OF DECK EDGE (TYP)

DECK CONCRETE

#4 @ 9"

4"

4 "

13" + 1"

The det
ai
l
s shown ar
e gui
del
i
nes and shoul
d notbe consi
der
ed st
andar
ds. The i
nf
or
m at
i
on has been obt
ai
ned f
r
om

1'-2"

#4 @ 9" (TYP.)

t
hr
ough t
hi
s gui
del
i
ne. I
fsuch ser
vi
ces ar
er
equi
r
ed,pl
ease seek an appr
opr
i
at
e pr
of
essi
onal
.

WWW.
PCI
NE.
ORG

1'-4"
2" TOP COVER

NOTE: DESIGNERS SHOULD


CONSULT WITH SEVERAL
FABRICATORS FOR LONG SPAN
SKEWED BEAMS REGARDING
POTENTIAL SHIPPING LIMITATIONS.

PLACE CURB IN GROUT BED

ANCHOR REAR FACE VERTICALS IN MIDDLE OF STRAND GRID

DRIP EDGE

5. THE DESIGNER SHALL DETAIL ADDITIONAL TOP LONGITUDINAL REINFORCING IN THE TOP FLANGE AT BEAM ENDS IF THE TOP FIBER STRESSES EXCEED 200 PSI. THESE
BARS ARE USED TO CONTROL TRANSVERSE CRACKING IN THE TOP FLANGE AT RELEASE. THIS REINFORCING SHALL BE DESIGNED IN ACCORDANCE WITH THE AASHTO LRFD
BRIDGE DESIGN SPECIFICATIONS. THIS REINFORCING IS FOR CRACK WIDTH AND LENGTH CONTROL, NOT PREVENTION. IF FULLY TENSIONED TOP STRAND ARE INCLUDED
IN THE DESIGN, IT IS RECOMMENDED THAT THEY NOT BE USED TO MEET THESE AASHTO PROVISIONS.

REVI
SI
ONS

I
SSUE DATE: 03 / 10 / 15
SHEET: NEXT 09

4. SPLAY STIRRUPS IN ENDS OF STEM. SEE SHEET 08 FOR THE LAYOUT OF STIRRUPS (SIMILAR TO NEXT F BEAMS).

NOTES: THIS DETAIL IS SCHEMATIC. ACTUAL DETAIL WOULD NEED TO BE FULLY DESIGNED.
STEEL RAIL IN CURB SHOWN, OTHER PARAPETS SIMILAR.
THIS DETAIL CAN BE MODIFIED FOR ANY TYPICAL PARAPET SHAPE INCLUDING F SHAPE PARAPETS.
ANCHOR BOLTS NOT SHOWN IN CURB.
ALL REINFORCING IN BEAM AND DECK POUR NOT SHOWN.
STIRRUP SPACING MAY NEED TO BE MODIFIED IF ONE LEG OF STIRRUP IS ELIMINATED.
DATE

3. PLACE 2-#4 BARS AT THE BEAM END, THEN #5 @ 6 INCHES IN THE TOP FLANGE TO CONTROL TOP FLANGE END CRACKING DURING RELEASE AND HANDLING. THE
MOST COMMON FORM OF POTENTIAL CRACKING IN THIS AREA IS A SERIES OF VERTICAL HAIRLINE CRACKS THROUGH THE INSIDE RADIUS OF THE TOP FLANGE / BEAM
STEM INTERFACE RUNNING PARALLEL TO THE STEM. #5 J BARS ARE USED TO SUPPLEMENT THIS REINFORCING. THE TWO J SHAPED BARS SHOWN MAY BE COMBINED
INTO ONE INVERTED U SHAPED BAR. THE USE OF A SEMI-INTEGRAL BACKWALL THAT IS CAST IN THE SHOP AS A SECONDARY POUR CAN HELP TO PREVENT THE
GROWTH OF THESE CRACKS DURING SHIPPING AND ERECTION.

NEXT E BEAM - RAILING OPTIONS

NO.

2. THE AMOUNT OF SPLITTING REINFORCING MAY BE REDUCED BY DEBONDING STRAND IN THIS AREA. ADDITIONAL SPLITTING REINFORCING SHOULD BE PLACED IN AREAS
WHERE DEBONDING IS TERMINATED.

DESCRI
PTI
ON

1. THE BARS SHOWN ARE APPROXIMATELY THE MAXIMUM NUMBER THAT CAN BE FIT WITHIN THE NEXT 24 BEAM. SOME OR ALL OF THESE ADDITIONAL END VERTICAL BARS
MAY NOT BE NECESSARY DEPENDING ON THE DESIGN.

CHANGED RAI
LI
NG TO CONCRETE BARRI
ER

NEXT BEAM

10 /2015

NEXT E BEAM - END REINFORCING DETAILS


NOTES:

END ELEVATION - STEM END

ELEVATION - STEM END

3"
3"

TM

MAXIMUM JOINT DIFFERENTIAL - OVERLAY DETAIL


2" MIN.

3"

DISCONTINUE BARS WHEN SPACING


TO ADJACENT BAR IS LESS THAN 3" (TYP)

3"

1
2"

TRANSVERSE DECK BARS (#4@6")


SPLAY IN ACUTE END REGION (TYP)

PROJECTING CONNECTION BARS (TYP)

GRINDING PLANE

MAXIMUM JOINT DIFFERENTIAL - BARE DECK DETAIL

CAMBER DIFFERENTIAL DETAILS

SHEAR REINFORCEMENT USED FOR


BURSTING STEEL IN END ZONE
STIRRUPS MAY BE
BUNDLED IN END
ZONE IF REQUIRED

J BARS MAY BE ADDED TO SKEWED BEAMS


TO CONTROL CRACKING DUE TO SHIPPING
AND HANDLING. SEE DETAILS ON SHEET 08

JOINT SEAL

WATERPROOFING MEMBRANE CURB


DETAILS AS PER STATE STANDARDS

1"

#4 BARS PLACED AT
BOTTOM OF TOP FLANGE.
SEE NOTE 3

CAST-IN-PLACE CONCRETE CURB


CAST IN THE FIELD OR AT THE
PRECAST FACILITY

MEMBRANE WATERPROOFING

RECOMMENDED MAX.
SKEW OF 20 DEGREES

BLOCKOUT (SEE
STATE STANDARDS)

BURSTING ZONE VERTICAL


REINFORCING. SEE NOTE 1

WEARING SURFACE

ADDITIONAL END ZONE


VERTICALS

STANDARD STIRRUP

OVERHANG (IF DESIRED)

ANCHOR REAR FACE VERTICALS IN MIDDLE OF STRAND GRID

03 /2016
2

NOTES: THIS DETAIL IS SCHEMATIC. ACTUAL DETAIL WOULD NEED TO BE FULLY DESIGNED.
STEEL RAIL IN CURB SHOWN, OTHER PARAPETS SIMILAR.
THIS DETAIL CAN BE MODIFIED FOR ANY TYPICAL PARAPET SHAPE INCLUDING F SHAPE PARAPETS.
ANCHOR BOLTS NOT SHOWN IN CURB.
ALL REINFORCING IN BEAM NOT SHOWN.

10 /2015

NEXT D BEAM - BARRIER/RAIL ATTACHMENT

REVI
SI
ONS

1. THE BARS SHOWN ARE APPROXIMATELY THE MAXIMUM NUMBER THAT CAN BE FIT WITHIN THE NEXT 28 D BEAM. SOME OR ALL OF THESE ADDITIONAL
END VERTICAL BARS MAY NOT BE NECESSARY DEPENDING ON THE DESIGN.
2. THE AMOUNT OF SPLITTING REINFORCING MAY BE REDUCED BY DEBONDING STRAND IN THIS AREA. ADDITIONAL SPLITTING REINFORCING SHOULD
BE PLACED IN AREAS WHERE DEBONDING IS TERMINATED.
3. PLACE 2-#4 BARS AT THE BEAM END IN THE TOP FLANGE TO CONTROL TOP FLANGE END CRACKING DURING RELEASE AND HANDLING. THE MOST
COMMON FORM OF POTENTIAL CRACKING IN THIS AREA IS A SERIES OF VERTICAL HAIRLINE CRACKS THROUGH THE INSIDE RADIUS OF THE TOP
FLANGE / BEAM STEM INTERFACE RUNNING PARALLEL TO THE STEM. #5 J BARS ARE USED TO SUPPLEMENT THIS REINFORCING.
THE TWO J SHAPED BARS SHOWN MAY BE COMBINED INTO ONE INVERTED U SHAPED BAR. THE USE OF A SEMI-INTEGRAL BACKWALL THAT IS CAST IN
THE SHOP AS A SECONDARY POUR CAN HELP TO PREVENT THE GROWTH OF THESE CRACKS DURING SHIPPING AND ERECTION.
4. BEAMS MAY BE FABRICATED WITH HIGHER SKEWS, HOWEVER ADDITIONAL CRACKING IN THE TOP FLANGE MAY OCCUR.
5. THE DESIGNER SHALL DETAIL ADDITIONAL TOP LONGITUDINAL REINFORCING IN THE TOP FLANGE AT BEAM ENDS IF THE TOP FIBER STRESSES
EXCEED 200 PSI. THESE BARS ARE USED TO CONTROL TRANSVERSE CRACKING IN THE TOP FLANGE AT RELEASE. THIS REINFORCING SHALL BE
DESIGNED IN ACCORDANCE WITH THE AASHTO LRFD BRIDGE DESIGN SPECIFICATIONS. THIS REINFORCING IS FOR CRACK WIDTH AND LENGTH
CONTROL, NOT PREVENTION.

NEXT BEAM

DESCRI
PTI
ON

NEXT D BEAM - END REINFORCING DETAILS

CHANGED RAI
LI
NG TO CONCRETE BARRI
ER

DRIP EDGE

ELEVATION - STEM END

DATE

NOTES:

END ELEVATION - STEM END


BURSTING ZONE = d/4
(AASHTO LRFD 5.10.10.1)

NO.

PLAN - SKEWED END

The det
ai
l
s shown ar
e gui
del
i
nes and shoul
d notbe consi
der
ed st
andar
ds. The i
nf
or
m at
i
on has been obt
ai
ned f
r
om

1
2"

DI
SCLAI
M ER:

NEXT D BEAM - MAIN DECK REINFORCING DETAILS


SKEWED BEAM ENDS

NOTES: 1. CONNECTOR REINFORCING TO BE PLACED ALONG THE ENTIRE SPAN WITH 6" SPACING.
2. FOR SKEWED BRIDGES, PLACE CONNECTOR REINFORCING PERPENDICULAR TO BEAM EDGE. BEND CONNECTOR REINFORCING
WITHIN THE FLANGE IN ACUTE CORNERS TO PRODUCE A SQUARE PROJECTION.
3. METHOD OF FORMING CLOSURE POUR TO BE DETERMINED BY THE CONTRACTOR. THE FORMS NEED TO BE REMOVABLE AND
ABLE TO ACCOMMODATE DIFFERENTIAL CAMBER. FORM SUPPORTS SHOULD NOT PENETRATE THROUGH TOP OF POUR UNLESS
APPROVED BY THE ENGINEER.
4. CLOSURE POUR MATERIAL IN LEFT DETAIL TO BE A NON SHRINK MIX THAT HAS A MINIMUM COMPRESSIVE STRENGTH OF
6000 PSI. THE GROUT MAY BE EXTENDED WITH AGGREGATE.
5. EXPOSED AGGREGATE SURFACE OF THE FACES OF THE KEYS IS RECOMMENDED TO IMPROVE GROUT BOND.
6. DESIGNERS ARE RESPONSIBLE FOR THE VERIFICATION OF THE DESIGN OF THIS JOINT. THIS DETAIL CAN BE CONSIDERED
EQUIVALENT TO A TENSION LAP SPLICE BASED ON A LAP EQUAL TO THE DEVELOPMENT LENGTH OF HOOKS IN TENSION AS
SPECIFIED IN THE AASHTO LRFD SPECIFICATIONS.
7. THE DESIGNER SHOULD ALLOW THE FABRICATOR TO MAKE MINOR CHANGES TO THE DIMENSIONS OF THE SHEAR KEYS TO
ACCOMMODATE VARIATIONS IN EXISTING FORMS.
8.THE DETAILS SHOWN ABOVE ARE BASED ON THE USE OF NON-SHRINK GROUTS AND UHPC. IT IS POSSIBLE TO DETAIL A
2
A JOINT WITH NORMAL DECK CONCRETE. THE DESIGN OF THE JOINT SHOULD FOLLOW THE AASHTO LRFD BRIDGE DESIGN
SPECIFICATIONS. REFER TO THE PCI NORTHEAST DECK BULB TEE BEAM DETAILS FOR EXAMPLES. NOTE THAT THE WIDTH
OF THE JOINT WILL AFFECT THE BEAM SPACING.

REM OVED EXTRA DECK BARS,ADDED J BARS,ADDED NOTE

OPTIONAL JOINT FORMING LINE IF


1" MINIMUM COVER CANNOT BE
OBTAINED WITH STRAIGHT FORM

NEXT D BEAM - FLANGE CONNECTOR DETAILS


PLAN

1" MIN.

STRAIGHT BARS WITH UHPC

- DECK DETAI
LS

PLAN

HOOKED BARS WITH NON-SHRINK GROUT

NEXT D BEAM

PLAN

1. USE THIS DETAIL FOR ALL SKEWED BEAMS.


2. OTHER REINFORCING BARS SUCH AS END ZONE REINFORCING
NOT SHOWN FOR CLARITY.
3. THE BAR LAYOUT SHOWN IS APPROXIMATE. THE
FABRICATOR SHALL LAY OUT BARS TO PROVIDE A MAXIMUM
OF 6" SPACING BETWEEN ADJACENT TRANSVERSE DECK BARS.

NORTHEAST EXTREM E TEE (


NEXT)BEAM DETAI
LS

RECOMMENDED 20 DEGREES MAX.


BEAMS WITH HIGHER SKEWS ARE
STRONGLY DISCOURAGED DUE TO POTENTIAL
FOR CRACKING IN THE TOP FLANGE DURING
FABRICATION AND HANDLING

NOTES:

PRECAST/
PRESTRESSED CONCRETE I
NSTI
TUTE NORTHEAST

#4 @ 6"

EXPOSED AGGREGATE
SURFACE." MINIMUM
AMPLITUDE (TYP.)

t
hr
ough t
hi
s gui
del
i
ne. I
fsuch ser
vi
ces ar
er
equi
r
ed,pl
ease seek an appr
opr
i
at
e pr
of
essi
onal
.

#4 @ 6"

PCI

OPTIONAL JOINT FORMING LINE IF


1" MINIMUM COVER CANNOT BE
OBTAINED WITH STRAIGHT FORM

4-#5
SECTION

Nor
t
heasti
s suppl
yi
ng i
nf
or
m at
i
on onl
y. PCINor
t
heasti
s notr
ender
i
ng engi
neer
i
ng orot
herpr
of
essi
onalser
vi
ces

#4 @ 6"

MIN.

2-#5

SECTION

2"

5" + 1"

#4 @ 6"

MIN.

1" MIN.

7" + "

SPLICE PROJECTING HOOP BARS


WITH MAIN DECK REINFORCING
21" MINIMUM LAP SPLICE (TYP)

EXPOSED AGGREGATE
SURFACE." MINIMUM
AMPLITUDE (TYP.)

ordam ages ar
i
si
ng outoft
hi
si
nf
or
m at
i
on. PCINor
t
heasthas publ
i
shed t
hi
s wor
k wi
t
ht
he under
st
andi
ng t
hatPCI

EXPOSED AGGREGATE
SURFACE. " MINIMUM
AMPLITUDE (TYP.)

BEND PROJECTING HOOP BARS JUST


INSIDE FACE OF DECK EDGE (TYP)

2 "

0"

2"

2 "
PROJECTING CONNECTION BAR (TYP)

I
SSUE DATE: 03 / 10 / 15

6"

sour
ces bel
i
eved t
o be r
el
i
abl
e. PCINor
t
heastori
t
s m em ber
shi
ps shal
lnotbe r
esponsi
bl
ef
orany er
r
or
s,om i
ssi
on

3" MIN.

OVERLAY

SHEET: NEXT 1
0

FILL WITH UHPC

0"

8"

1"

WWW.
PCI
NE.
ORG

FILL WITH NONSHRINK GROUT

2 "

7" + 1"

1"
3" MIN.

2" MIN.

9" + "

NOTE: DESIGNERS SHOULD


CONSULT WITH SEVERAL
FABRICATORS FOR LONG SPAN
SKEWED BEAMS REGARDING
POTENTIAL SHIPPING LIMITATIONS.

EXTEND STRAND AND/OR


REINFORCING INTO
DIAPHRAGM

CONTINUOUS DECK REINFORCING


TRANSVERSE DECK REINFORCING NOT SHOWN

END DIAPHRAGM

PCI

APPROACH SLAB

EXTEND PRESTRESSING
STRAND (TYP.)

NOTES:

4" DIAMETER BLOCKOUTS IN TOP FLANGE TO


FACILITATE CONCRETE PLACEMENT AND PREVENT VOIDS

1. THE DETAILS SHOWN ARE SCHEMATIC. REFER TO STATE STANDARDS FOR SPECIFIC DETAILS.
2. THE DESIGNER SHOULD SPECIFY THE TIMING AND SEQUENCE OF THE PLACEMENT OF THE
DECK AND CLOSURE POUR CONCRETE IN ORDER TO ALLOW FOR BEAM ROTATION WITHOUT
CRACKING OF THE END DIAPHRAGM.

REINFORCED DECK SLAB


REINFORCING NOT SHOWN
EXTEND STRAND AND/OR
REINFORCING TO PROVIDE
POSITIVE MOMENT
CONNECTION TO ABUTMENT

REINFORCED DECK SLAB


REINFORCING NOT SHOWN

CLOSURE POUR
REINFORCING BETWEEN STEMS
PRECAST APPROACH
SLAB

EXTEND STRAND AND/OR


REINFORCING TO PROVIDE
CONNECTION TO BACKWALL

DI
SCLAI
M ER:

NEXT F - SAMPLE PIER CONTINUITY DETAIL

PRECAST APPROACH
SLAB
CORRUGATED METAL PIPE VOID

ELASTOMERIC BEARING
SEMI-INTEGRAL BACKWALL. SECONDARY POUR
IN PLANT OR FIELD CAST.
NOTE: ALL REINFORCEMENT NOT SHOWN

PRECAST INTEGRAL ABUTMENT

- SUBSTRUCTURE DETAI
LS

1. THESE DETAILS ARE BASED ON MASSACHUSETTS DEPARTMENT OF TRANSPORTAION STANDARDS FOR TYPE 1
APPROACH SLABS. DETAILS FOR OTHER STATES WILL VARY.

NEXT F BEAM

PIER CAP

NORTHEAST EXTREM E TEE (


NEXT)BEAM DETAI
LS

DOWEL PIN IF REQUIRED BY DESIGN

NOTES:

2. INTERMEDIATE DIAPHRAGMS ARE NOT REQUIRED.

The det
ai
l
s shown ar
e gui
del
i
nes and shoul
d notbe consi
der
ed st
andar
ds. The i
nf
or
m at
i
on has been obt
ai
ned f
r
om

EXPANDED POLYSTYRENE

NEXT F - SAMPLE END DIAPHRAGM DETAIL


CANTILEVER ABUTMENT

Nor
t
heasti
s suppl
yi
ng i
nf
or
m at
i
on onl
y. PCINor
t
heasti
s notr
ender
i
ng engi
neer
i
ng orot
herpr
of
essi
onalser
vi
ces

ELASTOMERIC BEARING (TYP)

ordam ages ar
i
si
ng outoft
hi
si
nf
or
m at
i
on. PCINor
t
heasthas publ
i
shed t
hi
s wor
k wi
t
ht
he under
st
andi
ng t
hatPCI

CLOSED CELL FOAM


EXPANDED POLYSTYRENE FOAM
BELOW DIAPHRAGM

sour
ces bel
i
eved t
o be r
el
i
abl
e. PCINor
t
heastori
t
s m em ber
shi
ps shal
lnotbe r
esponsi
bl
ef
orany er
r
or
s,om i
ssi
on

TM

#5 (TYP)

PRECAST/
PRESTRESSED CONCRETE I
NSTI
TUTE NORTHEAST

BEAM END (TYP)

t
hr
ough t
hi
s gui
del
i
ne. I
fsuch ser
vi
ces ar
er
equi
r
ed,pl
ease seek an appr
opr
i
at
e pr
of
essi
onal
.

WWW.
PCI
NE.
ORG

CLOSURE POUR

REINFORCED DECK SLAB


REINFORCING NOT SHOWN

ABUTMENT STEM
CLOSED CELL FOAM OR OTHER
COMNPRESSIBLE MATERIAL

NOTES:

1. THESE DETAILS ARE BASED ON MASSACHUSETTS DEPARTMENT OF TRANSPORTATION STANDARDS FOR TYPE 2
APPROACH SLABS. DETAILS FOR OTHER STATES WILL VARY.

1. THESE DETAILS ARE BASED ON MASSACHUSETTS DEPARTMENT OF TRANSPORTATION STANDARDS FOR TYPE 2
APPROACH SLABS. DETAILS FOR OTHER STATES WILL VARY.

NO.

DATE

2. A PRECAST PIECE SIMILAR TO THE BACKWALL PIECE CAN BE USED AT THE ENDS OF THE ABUTMENT ALSO.

I
SSUE DATE: 03 / 10 / 15

NEXT F - SAMPLE INTEGRAL ABUTMENT SECTION

SHEET: NEXT 1
1

NOTES:

REVI
SI
ONS

NEXT F - SAMPLE SEMI-INTEGRAL ABUTMENT SECTION

DESCRI
PTI
ON

PILE

EXTEND STRAND AND/OR


REINFORCING INTO
DIAPHRAGM

CONTINUOUS DECK REINFORCING


TRANSVERSE DECK REINFORCING NOT SHOWN

END DIAPHRAGM

PCI

APPROACH SLAB

ELASTOMERIC BEARING (TYP)

EXTEND PRESTRESSING
STRAND (TYP.)

The det
ai
l
s shown ar
e gui
del
i
nes and shoul
d notbe consi
der
ed st
andar
ds. The i
nf
or
m at
i
on has been obt
ai
ned f
r
om

EXPANDED POLYSTYRENE

1. THESE DETAILS ARE BASED ON MASSACHUSETTS DEPARTMENT OF TRANSPORTATION STANDARDS FOR TYPE 1
APPROACH SLABS. DETAILS FOR OTHER STATES WILL VARY.

NEXT E - SAMPLE PIER CONTINUITY DETAIL


2. INTERMEDIATE DIAPHRAGMS ARE NOT REQUIRED.
NOTES:

4" DIAMETER BLOCKOUTS IN TOP FLANGE TO


FACILITATE CONCRETE PLACEMENT AND PREVENT VOIDS

1. THE DETAILS SHOWN ARE SCHEMATIC. REFER TO STATE STANDARDS FOR SPECIFIC DETAILS.
2. THE DESIGNER SHOULD SPECIFY THE TIMING AND SEQUENCE OF THE PLACEMENT OF THE
DECK AND CLOSURE POUR CONCRETE IN ORDER TO ALLOW FOR BEAM ROTATION WITHOUT
CRACKING OF THE END DIAPHRAGM.

REINFORCED DECK SLAB


REINFORCING NOT SHOWN
EXTEND STRAND AND/OR
REINFORCING TO PROVIDE
POSITIVE MOMENT
CONNECTION TO ABUTMENT

REINFORCED DECK SLAB


REINFORCING NOT SHOWN

CLOSURE POUR
REINFORCING BETWEEN STEMS
PRECAST APPROACH
SLAB

EXTEND STRAND AND/OR


REINFORCING TO PROVIDE
CONNECTION TO BACKWALL

NOTE: ALL REINFORCING NOT SHOWN

DI
SCLAI
M ER:

NOTES:

PRECAST APPROACH
SLAB
CORRUGATED METAL PIPE VOID

ELASTOMERIC BEARING
SEMI-INTEGRAL BACKWALL. SECONDARY POUR
IN PLANT OR FIELD CAST.
NOTE: ALL REINFORCEMENT NOT SHOWN

PRECAST INTEGRAL ABUTMENT

- SUBSTRUCTURE DETAI
LS

PIER CAP

NEXT E BEAM

CANTILEVER ABUTMENT

NORTHEAST EXTREM E TEE (


NEXT)BEAM DETAI
LS

DOWEL PIN IF REQUIRED BY DESIGN

NEXT E - SAMPLE END DIAPHRAGM DETAIL

Nor
t
heasti
s suppl
yi
ng i
nf
or
m at
i
on onl
y. PCINor
t
heasti
s notr
ender
i
ng engi
neer
i
ng orot
herpr
of
essi
onalser
vi
ces

EXPANDED POLYSTYRENE FOAM


BELOW DIAPHRAGM

ordam ages ar
i
si
ng outoft
hi
si
nf
or
m at
i
on. PCINor
t
heasthas publ
i
shed t
hi
s wor
k wi
t
ht
he under
st
andi
ng t
hatPCI

CLOSED CELL FOAM


ELASTOMERIC BEARING

sour
ces bel
i
eved t
o be r
el
i
abl
e. PCINor
t
heastori
t
s m em ber
shi
ps shal
lnotbe r
esponsi
bl
ef
orany er
r
or
s,om i
ssi
on

TM

#5 (TYP)

PRECAST/
PRESTRESSED CONCRETE I
NSTI
TUTE NORTHEAST

BEAM END (TYP)

t
hr
ough t
hi
s gui
del
i
ne. I
fsuch ser
vi
ces ar
er
equi
r
ed,pl
ease seek an appr
opr
i
at
e pr
of
essi
onal
.

WWW.
PCI
NE.
ORG

CLOSURE POUR

REINFORCED DECK SLAB


REINFORCING NOT SHOWN

ABUTMENT STEM
CLOSED CELL FOAM OR OTHER
COMNPRESSIBLE MATERIAL

1. THESE DETAILS ARE BASED ON MASSACHUSETTS DEPARTMENT OF TRANSPORTATION STANDARDS FOR TYPE 2
APPROACH SLABS. DETAILS FOR OTHER STATES WILL VARY.

NOTES:

NO.

2. A PRECAST PIECE SIMILAR TO THE BACKWALL PIECE CAN BE USED AT THE ENDS OF THE ABUTMENT ALSO.

DATE

1. THESE DETAILS ARE BASED ON MASSACHUSETTS DEPARTMENT OF TRANSPORTATION STANDARDS FOR TYPE 2
APPROACH SLABS. DETAILS FOR OTHER STATES WILL VARY.

I
SSUE DATE: 03 / 10 / 15

NEXT E - SAMPLE INTEGRAL ABUTMENT SECTION

SHEET: NEXT 1
2

NOTES:

REVI
SI
ONS

NEXT E - SAMPLE SEMI-INTEGRAL ABUTMENT SECTION

DESCRI
PTI
ON

PILE

REINFORCED DECK SLAB


REINFORCING NOT SHOWN

CONTINUOUS DECK REINFORCING


TRANSVERSE DECK REINFORCING NOT SHOWN

CAST-IN-PLACE CONCRETE
END DIAPHRAGM

ELASTOMERIC BEARING (TYP)

EXTEND PRESTRESSING
STRAND (TYP.)

The det
ai
l
s shown ar
e gui
del
i
nes and shoul
d notbe consi
der
ed st
andar
ds. The i
nf
or
m at
i
on has been obt
ai
ned f
r
om

EXPANDED POLYSTYRENE

1. THESE DETAILS ARE SIMILAR TO MASSACHUSETTS DEPARTMENT OF TRANSPORTATION STANDARDS FOR TYPE 1
APPROACH SLABS. DETAILS FOR OTHER STATES WILL VARY.
2. INTERMEDIATE DIAPHRAGMS ARE NOT REQUIRED.

NEXT D - SAMPLE PIER CONTINUITY DETAIL


NOTES:
4" DIAMETER BLOCKOUTS IN TOP FLANGE TO
FACILITATE CONCRETE PLACEMENT AND PREVENT VOIDS

1. THE DETAILS SHOWN ARE SCHEMATIC. REFER TO STATE STANDARDS FOR SPECIFI DETAILS.
2. IF THE TOP FLANGE IS BLOCKED OUT AS SHOWN, THE ENGINEER SHOULD CHECK STRESSES IN THE
REMAINING STEM (WITHOUT THE FLANGE). DEBONDING OF STRAND OR ADDITIONAL REINFORCMENT
MAY BE REQUIRED TO ADDRESS THIS CONDITION.

REINFORCED DECK SLAB


REINFORCING NOT SHOWN
EXTEND STRAND AND/OR
REINFORCING TO PROVIDE
POSITIVE MOMENT
CONNECTION TO ABUTMENT
CLOSURE POUR
REINFORCING BETWEEN STEMS
PRECAST APPROACH
SLAB

DI
SCLAI
M ER:

EXTEND STRAND AND/OR


REINFORCING TO PROVIDE
CONNECTION TO BACKWALL

PRECAST INTEGRAL ABUTMENT

SEMI-INTEGRAL BACKWALL. SECONDARY POUR


IN PLANT OR FIELD CAST.
NOTE: ALL REINFORCEMENT NOT SHOWN
ABUTMENT STEM
CLOSED CELL FOAM OR OTHER
COMNPRESSIBLE MATERIAL

NEXT D - SAMPLE INTEGRAL ABUTMENT SECTION


NOTES:

NEXT D - SAMPLE SEMI-INTEGRAL ABUTMENT SECTION


1. THESE DETAILS ARE BASED ON MASSACHUSETTS DEPARTMENT OF TRANSPORTATION STANDARDS FOR TYPE 2
APPROACH SLABS. DETAILS FOR OTHER STATES WILL VARY.

NO.

1. THESE DETAILS ARE BASED ON MASSACHUSETTS DEPARTMENT OF TRANSPORTATION STANDARDS FOR TYPE 2
APPROACH SLABS. DETAILS FOR OTHER STATES WILL VARY.

DATE

NOTES:
2. A PRECAST PIECE SIMILAR TO THE BACKWALL PIECE CAN BE USED AT THE ENDS OF THE ABUTMENT ALSO.

I
SSUE DATE: 03 / 10 / 15

PRECAST APPROACH
SLAB

ELASTOMERIC BEARING

SHEET: NEXT 1
3

PILE

NOTE: ALL REINFORCEMENT NOT SHOWN

REVI
SI
ONS

CORRUGATED METAL PIPE VOID

REINFORCED DECK SLAB


REINFORCING NOT SHOWN

DESCRI
PTI
ON

NOTE: ALL REINFORCING NOT SHOWN

- SUBSTRUCTURE DETAI
LS

PIER CAP

NEXT D BEAM

CANTILEVER ABUTMENT
NOTES:

NORTHEAST EXTREM E TEE (


NEXT)BEAM DETAI
LS

DOWEL PIN IF REQUIRED BY DESIGN

NEXT D - SAMPLE END DIAPHRAGM DETAIL

Nor
t
heasti
s suppl
yi
ng i
nf
or
m at
i
on onl
y. PCINor
t
heasti
s notr
ender
i
ng engi
neer
i
ng orot
herpr
of
essi
onalser
vi
ces

CLOSED CELL FOAM


EXPANDED POLYSTYRENE FOAM
AROUND BEARINGS AND BELOW
DIAPHRAGM

ordam ages ar
i
si
ng outoft
hi
si
nf
or
m at
i
on. PCINor
t
heasthas publ
i
shed t
hi
s wor
k wi
t
ht
he under
st
andi
ng t
hatPCI

EXTEND STRAND AND/OR


REINFORCING FROM BEAM
END TO SUPPORT DIAPHRAGM

sour
ces bel
i
eved t
o be r
el
i
abl
e. PCINor
t
heastori
t
s m em ber
shi
ps shal
lnotbe r
esponsi
bl
ef
orany er
r
or
s,om i
ssi
on

TM

PCI

APPROACH SLAB

PRECAST/
PRESTRESSED CONCRETE I
NSTI
TUTE NORTHEAST

CLOSURE POUR
BEAM END (TYP)

t
hr
ough t
hi
s gui
del
i
ne. I
fsuch ser
vi
ces ar
er
equi
r
ed,pl
ease seek an appr
opr
i
at
e pr
of
essi
onal
.

WWW.
PCI
NE.
ORG

BLOCK OUT TOP FLANGE TO ALLOW


FOR FLOW OF CONCRETE

BRIDGE SEAT

ELASTOMERIC BEARING

BRIDGE SEAT

11"

FRONT ELEVATION
BEAM STEM

FRONT ELEVATION
BEVELED SOLE PLATE
WITH KEEPER TABS

ELASTOMERIC BEARING

BEVELED SOLE PLATE


WITH KEEPER TABS

3 "

BEAM STEM

TAPERED INTERNAL SOLE PLATE

ELASTOMERIC BEARING

ELASTOMERIC BEARING

NOTES:
1. THESE DETAILS ARE ONLY REQUIRED FOR NON-INTEGRAL SUBSTRUCTURES WITH BEARINGS THAT ARE EQUAL
TO OR LESS THAN 11 1/2" WIDE.
2. A TAPERED ELASTOMERIC BEARINGS IS SHOWN. THIS IS BASED ON MASSACHUSETTS DEPARTMENT OF
TRANSPORTATION STANDARDS THAT INCLUDE THE USE OF AN EMBEDDED TAPERED STEEL SOLE PLATE IN
THE BEARING. DETAILS FOR OTHER STATES WILL VARY.
3. BRIDGE SEAT AND BEARING MAY BE SLOPED TO MATCH THE CROSS SLOPE OF THE ROADWAY ABOVE.
4. ELASTOMERIC SHIMS MAY BE USED TO PROPERLY SEAT BEAMS AND ADJUST THE ELEVATION OF THE TOP
OF THE BEAM.
5. TYPICAL KEEPER BLOCKS MAY BE USED BETWEEN THE STEMS FOR LATERAL RESISTANCE.

WIDE BEARING DETAILS


BOLTED OPTION

NOTES:
1. THESE DETAILS ARE ONLY REQUIRED FOR NON-INTEGRAL SUBSTRUCTURES.
2. BEARING MAY BE TAPERED IN LIEU OF THE BEVELED SOLE PLATE. SEE NARROW BEARING DETAILS ON THIS SHEET.
3. BRIDGE SEAT AND BEARING ASSEMBLY SHOULD BE SLOPED TO MATCH THE CROSS SLOPE OF THE ROADWAY ABOVE.
4. THE SOLE PLATE CAN BE KEPT IN PLACE WITH FRICTION (NON-BOLTED OPTION). ADDITIONAL FIXITY CAN BE
OBTAINED BY BOLTING THE SIDE TABS INTO THE BEAM STEM (BOLTED OPTION).
5. THE NON-BOLTED OPTION IS THE PREFERRED OPTION. USE OF THE BOLTED OPTION MAY REQUIRE THE DRILLING OF
HOLES IN THE BEAM FORM FOR THE INSERTS.
6. ELASTOMERIC SHIMS MAY BE USED BETWEEN THE BOTTOM OF STEM AND TOP OF PLATE ON NON-BOLTED BEARINGS
TO PROPERLY SEAT BEAMS AND ADJUST THE ELEVATION OF THE TOP OF THE BEAM. BOLTED BEARINGS WOULD REQUIRE
THE SHIMS TO BE PLACED ON TOP OF OR BELOW THE BEARING.
7. TYPICAL KEEPER BLOCKS MAY BE USED BETWEEN THE STEMS FOR LATERAL RESISTANCE.
8. THE BOLTED PLATE OPTION SHOWN MAY BE MODIFIED TO PRODUCE A TYPICAL FIXED ELASTOMERIC BEARING. REFER
TO STATE STANDARDS.

OPTION 2: THREADED ROD INSERTED THROUGH


SLEEVE CAST INTO TOP FLANGE

THREADED INSERT CAST INTO


UNDERSIDE OF TOP FLANGE

1. HANGER RODS FOR UTILITIES SHOULD BE ATTACHED TO THE BEAM BY MEANS OF CAST-IN-PLACE INSERTS OR THROUGH
SLEEVES CAST INTO THE TOP FLANGE. OVERHEAD DRILLED-IN ANCHORS SHOULD NOT BE USED. REFER TO STATE
POLICIES FOR OVERHEAD ANCHORING.
2. PLACEMENT OF ANCHORS IN THE STEM OF THE BEAM SHOULD BE AVOIDED DUE TO THE POTENTIAL FOR INTERFERENCE
WITH THE STEM REINFORCING AND STRAND AND THE DIFFICULTIES OF SETTING ANCHORS PRIOR TO CASTING.
3. ONE TYPE OF UTILITY SHOWN, OTHER UTILITIES SIMILAR. REFER TO INDIVIDUAL UTILITY COMPANY DETAILS.
4. THIS DETAIL SHOWS THE UTILITY SUPPORT BETWEEN AT THE CENTERLINE OF THE BEAM. OTHER LOCATIONS ARE
ACCEPTABLE.
5. THE DESIGN ENGINEER SHOULD DETAIL ANY ADDITIONAL REINFORCING REQUIRED TO RESIST THE UTILITY LOADS.

1. HANGER RODS FOR UTILITIES SHOULD BE ATTACHED TO THE BEAM BY MEANS OF CAST-IN-PLACE INSERTS. OVERHEAD
DRILLED-IN ANCHORS SHOULD NOT BE USED. REFER TO STATE POLICIES FOR OVERHEAD ANCHORING.
2. PLACEMENT OF THE ANCHORS IN THE FLANGE IS PREFERRED. PLACEMENT OF ANCHORS IN THE STEM MAY BE
CONSIDERED, HOWEVER THE POTENTIAL FOR INTERFERENCE WITH THE STEM REINFORCING AND STRAND SHOULD BE
INVESTIGATED.
3. ONE TYPE OF UTILITY SHOWN, OTHER UTILITIES SIMILAR. REFER TO INDIVIDUAL UTILITY COMPANY DETAILS.
4. THIS DETAIL SHOWS THE UTILITY SUPPORT BETWEEN AT THE CENTERLINE OF THE BEAM. OTHER LOCATIONS ARE
ACCEPTABLE.
5. THE DESIGN ENGINEER SHOULD DETAIL ANY ADDITIONAL REINFORCING REQUIRED TO RESIST THE UTILITY LOADS.

REVI
SI
ONS

I
SSUE DATE: 03 / 10 / 15

NOTES:

SHEET: NEXT 1
4

NOTES:

DATE

NEXT D BEAM
SAMPLE UTILITY SUPPORT DETAILS

NO.

NEXT F AND E BEAMS


SAMPLE UTILITY SUPPORT DETAILS

DESCRI
PTI
ON

DI
SCLAI
M ER:

OPTION 1: THREADED INSERT CAST


INTO UNDERSIDE OF TOP FLANGE

The det
ai
l
s shown ar
e gui
del
i
nes and shoul
d notbe consi
der
ed st
andar
ds. The i
nf
or
m at
i
on has been obt
ai
ned f
r
om

NARROW ELASTOMERIC BEARING DETAILS

WIDE BEARING DETAILS


NON-BOLTED OPTION

DETAI
LS

SIDE ELEVATION

MI
SCELLANEOUS NEXT BEAM

SIDE ELEVATION
SIDE ELEVATION

NORTHEAST EXTREM E TEE (


NEXT)BEAM DETAI
LS

BRIDGE SEAT

Nor
t
heasti
s suppl
yi
ng i
nf
or
m at
i
on onl
y. PCINor
t
heasti
s notr
ender
i
ng engi
neer
i
ng orot
herpr
of
essi
onalser
vi
ces

BEAM STEM

ordam ages ar
i
si
ng outoft
hi
si
nf
or
m at
i
on. PCINor
t
heasthas publ
i
shed t
hi
s wor
k wi
t
ht
he under
st
andi
ng t
hatPCI

MAX.

sour
ces bel
i
eved t
o be r
el
i
abl
e. PCINor
t
heastori
t
s m em ber
shi
ps shal
lnotbe r
esponsi
bl
ef
orany er
r
or
s,om i
ssi
on

TM

FRONT ELEVATION

PCI

BRIDGE SEAT

PRECAST/
PRESTRESSED CONCRETE I
NSTI
TUTE NORTHEAST

ELASTOMERIC BEARING

BEVELED SOLE PLATE


WITH KEEPER TABS

" THICK NEOPRENE PAD

t
hr
ough t
hi
s gui
del
i
ne. I
fsuch ser
vi
ces ar
er
equi
r
ed,pl
ease seek an appr
opr
i
at
e pr
of
essi
onal
.

BEVELED SOLE PLATE


WITH KEEPER TABS

ELASTOMERIC BEARING

BEAM STEM

WWW.
PCI
NE.
ORG

" THICK NEOPRENE PAD

BEAM STEM

BEAM STEM

PLACE INSERT BETWEEN STRAND ROWS.


DESIGNER TO SIZE INSERT BASED ON
ANTICIPATED LOADS. LOOP FERRULE
INSERT SHOWN, OTHERS SIMILAR.