Office Lum/LED

RC700B

Installation instruction/

444170096881

IP20

Description

Wattage

Voltage

CCT

Frequency

Mounting

Accessories / :

RC700B LED36S PSU W12L120

(S)

35W

220V-240V~

50/60Hz

4000K

4.15

RC700B LED27S PSU W12L90

(S)

27W

220V-240V~

50/60Hz

4000K

3.45

Recessed

RC700B LED18S PSU W12L60

(S)

18W

220V-240V~

50/60Hz

4000K

2.25

(S) Suspension

RC700B LED22S PSU RA

(S)

22W

220V-240V~

50/60Hz

4000K

2.75

RC700B LED36S PSD W12L120

(S)

35W

220V-240V~

50/60Hz

4000K

4.25

4000K

3.5

Recessed

4000K

2.3

(S) Suspension

4000K

2.8

RC700B LED27S PSD W12L90

(S)

27W

220V-240V~

50/60Hz

RC700B LED18S PSD W12L60

(S)

18W

220V-240V~

50/60Hz

RC700B LED22S PSD RA

(S)

220V-240V~

22W

50/60Hz

Right Angle dimension

Suspension

57,4

210
420

210

W12L120
W12L90
W12L60

123,2
84

420

120

210

420

123,2

Recessed

107
84

420

120

107

Recessed

210

Linear type dimension


Suspension

1. /

2.
3.

A(mm) B(mm) C(mm) D(mm)


1200
120
84
600
900
120
84
600
600
120
84
400

120

120

Suspension
1

Ceiling unit installation

6003mm

12003mm
9003mm

12003mm
9003mm

A Fix Ceiling unit in ceiling with


screws

6003mm

steel rope into top holder cap and


B Insert
wrest cap into holder body

600mm

2 Fix part installation

Fix part
D8
WSH D8 TO A2

Fix bracket

Levering and remove the end cap with straight

fixing part for suspension rope


B Install

A screwdriver and pull-out the gear assy

Philips (China) Investment Co., Ltd.


Address: Room 1602-1605, No.218 Tianmuxi Road, Shanghai, P.R. China
Postalcode: 200070

2181602-1605
200070

RDC
12/01/2015
Yuan liu lin

RDC
12/01/2015
Alex Zhang

3 Luminnaires mounting --stater


A Insert suspension rope into string fix
part, push luminaire horizontal and
adjust to assigned position.

B Press fix part to adjust hanging length, and


leave the rest string inside the house and
tied together.

C Adjust string fix part position as needed

D Insert the external power and DALI cable into


housing.

Wiring /

30

40

/Cable
Red
Yellow/Green
Black
Blue
White

L
GND
N
DA/Ls
DA/N

Terminal for DALI only


DALI

Power cable entry

30

GND
N
DA/Ls

Connect wires (Take care of poles)


()

DA/N

DALI cable entry


DALI

60245 IEC57 21.0~1.5mm


60245 IEC57 31.0~1.5mm

5 Housing Connection

A Pull down the reflector assy and fix


B
the connection bracket into housing.

Insert the connection bracket into


C Push the spring connect piece in
till the shrapnel stuck.
another housing.

RDC

12/01/2015
Alex Zhang

Luminaires mounting Middle/End

The same installation as step 2,3,4,5


2,3,4,5

Click

A
Click

Adjust the gear spring to housing spring, push up and connect.

Adjust horizontally the luminaire to the before, and connect.

Push the diffuser to leave the gap as less as possible.

Connect the subsequent stripe or RA luminaires in turns.

The 600mm type should be used for end only.


600mm

Tear the diffuser protect film down.

Recessed
1 Pole bracket installation
B
M5x10
M5 bolt

A
C

D5
D5 Spring Washer A2

D5
D5 flat Washer A2

Levering and remove the end cap with straight

A screwdriver and pull-out the gear assy


B

Lever up the safety eyelet hole

RDC
12/01/2015
Alex Zhang

C Install the rod bracket on the rear of


the housing

Safety string and suspension pole installation

Fixing the pole to ceiling surfaceand the distance of


surface mounting refer to Dimension A&D
A
D

C
D

Install the pole into bracket ,and adjust the


position as needed

Hook luminaires with safety string

Install the Luminaire into the pole bracket, and


adjust the position as needed.

Insert the external power and DALI cable into


housing.

Remove the safety string

Wiring /
6

30

40

/Cable
Red
Yellow/Green
Black
Blue
White

L
GND
N
DA/Ls
DA/N

Terminal for DALI only


DALI

Power cable entry

30

GND
N
DA/Ls

Connect wires (Take care of poles)


()

DA/N

DALI cable entry


DALI

60245 IEC57 21.0~1.5mm


60245 IEC57 31.0~1.5mm

4 Housing Connection

A Pull down the reflector assy and fix


B
the connection bracket into housing.

Insert the connection bracket into


C Push the spring connect piece in
till the shrapnel stuck.
another housing.

RDC

12/01/2015
Alex Zhang

Luminaires mounting
The same installation as step 1,2,3,4
1,2,3,4

Adjust the gear spring to housing spring, push and


connect.

Adjust horizontally the luminaire to the before, and connect.

Push the diffuser to leave the gap as less as possible. D The 600mm type should be used for end only.
600mm

Filling the rest of end ceiling with ceiling plate if the length does not match of luminaires serial and ceiling .

Tear the diffuser protect film down.

C Connect the subsequent stripe or RA luminaires in


turns.

Maintenance
1. In order to ensure optimum performance, please clean the luminaire regularly(recommended twice a
year).While cleaning the luminaire, please use a soft cotton pad only.

2. The light source contained in this luminaire shall only be replaced by the manufacturer or his service agent or
a similar qualified person.

3. Do not touch electronic components! ESD sensitive.

4. Do not stare at the LED beam.


LED
5. The luminaire shall be installed by a qualified electrician and wired in accordance with the latest IEE electrical
regulations or the national requirements.
IEE
6. This luminaire is only suitable for indoor usage. And not suitable for the corrosive environment and area
prone to hurricane and extreme winds.

RDC