You are on page 1of 15

Project:

Pile Structural Capacity


Mott MacDonald Singapore
Dvn/Dept:
Structural Job No./File No.
258520
Calculated by:
KKL
Date:
16 Aug 2010
Sheet No.
Checked by:
Date:
16 Aug 2010
AW
1
Dwg Reference:
OUTPUT

Calculations for:
Rochor Station
Pile Design
CPD-01
REF

Diameter of Pile
Concrete Grade

D
fcu

=
=

800
40

Rebar provided

9 T 20

Dia of link

13 mm

Cover to link

75 mm

Max Com Force


Max Ten Force

Fc
Ft

=
=

mm
N/mm2

3100
0

kN
kN

Design Status:
OK
211 mm
Spacing of Rebar
Percentage Rebar 0.57 %

Max Crack width

0.25

Percentage of reinforcement provided ( 0.5% minimum, 4.0% maximum)


= As/Ac*100
= 0.57 %
OK !

Structural Capacity
** Compression

(CP 4- 7.4.5.3)

Allowable compression capacity for rock socketed reinforced bored cast-in-place


pile with full length of reinforcement is given by;
Fc = [0.4fcuAc + 0.75fyAs]/Fs
Where Fs >= 2 CP4 7.4.5.3
Fs = [0.4fcuAc + 0.75fyAs]/Fc
2.9

Fs =

** Tension
Ultimate Ten Capacity
Tension Crack width
Crack width Location
Spacing of bar

Where

As =
Ac =

> 2, OK !

= 0.57*fy*As
= 741.651 kN

(LTA DC - 6.2.3.9)
> Ft, OK !

(CP 73 - Annex B7)


Co =
S =

53 mm
211 mm

The equation for the crack width under direct tension only is given by,
Wcr
= 3*acr*m
\where,
acr
= 113 mm
m
= 1 - 2*Ac / (3*Es*As)
1
= Ft / (As*Es)
=
0

m
Wcr

=
=

-0.00059
-0.2 mm

< 0.25, OK !

2828.57 mm2
500029 mm2

Project:

Pile Structural Capacity


Mott MacDonald Singapore
Structural Job No./File No.
Dvn/Dept:
258520
Calculated by:
KKL
Date:
16 Aug 2010
Sheet No.
Checked by:
AW
Date:
16 Aug 2010
2
Dwg Reference:
OUTPUT

Calculations for:
Rochor Station
Pile Design
REF
CPD-02

Diameter of Pile
Concrete Grade

D
fcu

=
=

800
40

Rebar provided

9 T 20

Dia of link

13 mm

Cover to link

75 mm

Max Com Force


Max Ten Force

Fc
Ft

=
=

mm
N/mm2

2850
500

kN
kN

Design Status:
OK
Spacing of Rebar
211 mm
Percentage Rebar 0.57 %

Max Crack width

0.25

Percentage of reinforcement provided ( 0.5% minimum, 4.0% maximum)


= As/Ac*100
= 0.57 %
OK !

Structural Capacity
** Compression

(CP 4- 7.4.5.3)

Allowable compression capacity for rock socketed reinforced bored cast-in-place


pile with full length of reinforcement is given by;
Fc = [0.4fcuAc + 0.75fyAs]/Fs
Where Fs >= 2 CP4 7.4.5.3
Fs = [0.4fcuAc + 0.75fyAs]/Fc
Fs =

3.15

** Tension
Ultimate Ten Capacity
Tension Crack width
Crack width Location
Spacing of bar

Where

As =
Ac =

> 2, OK !

= 0.57*fy*As
= 741.651 kN

(LTA DC - 6.2.3.9)
> Ft, OK !

(CP 73 - Annex B7)


Co =
S =

53 mm
211 mm

The equation for the crack width under direct tension only is given by,
Wcr
= 3*acr*m
\where,
acr
= 113 mm
m
= 1 - 2*Ac / (3*Es*As)
1
= Ft / (As*Es)
= 0.00088

m
Wcr

=
=

0.00029
0.1 mm

< 0.25, OK !

2828.57 mm2
500029 mm2

Project:

Pile Structural Capacity


Mott MacDonald Singapore
Dvn/Dept:
Structural Job No./File No.
258520
Calculated by:
KKL
Date:
16 Aug 2010
Sheet No.
Checked by:
AW
16 Aug 2010
Date:
3
Dwg Reference:
OUTPUT

Calculations for:
Rochor Station
Pile Design
CPD-03
REF

Diameter of Pile
Concrete Grade

D
fcu

=
=

1000
40

mm
N/mm2

Rebar provided

= 13 T 20

Dia of link

13 mm

Cover to link

75 mm

Max Com Force


Max Ten Force

Fc
Ft

=
=

5500
250

kN
kN

Design Status:
OK
Spacing of Rebar
194 mm
Percentage Rebar 0.52 %

Max Crack width

0.25

Percentage of reinforcement provided ( 0.5% minimum, 4.0% maximum)


= As/Ac*100
= 0.52 %
OK !

Structural Capacity
** Compression

(CP 4- 7.4.5.3)

Allowable compression capacity for rock socketed reinforced bored cast-in-place


pile with full length of reinforcement is given by;
Fc = [0.4fcuAc + 0.75fyAs]/Fs
Where Fs >= 2 CP4 7.4.5.3
Fs = [0.4fcuAc + 0.75fyAs]/Fc
2.53

Fs =

** Tension
Ultimate Ten Capacity
Tension Crack width
Crack width Location
Spacing of bar

Where

As =
Ac =

> 2, OK !

= 0.57*fy*As
= 1071.27 kN

(LTA DC - 6.2.3.9)
> Ft, OK !

(CP 73 - Annex B7)


Co =
S =

53 mm
194 mm

The equation for the crack width under direct tension only is given by,
Wcr
= 3*acr*m
\where,
acr
= 106 mm
m
= 1 - 2*Ac / (3*Es*As)
1
= Ft / (As*Es)
= 0.00031

m
Wcr

=
=

-0.00033
-0.11 mm

< 0.25, OK !

4085.71 mm2
781629 mm2

Project:

Pile Structural Capacity


Mott MacDonald Singapore
Dvn/Dept:
Structural Job No./File No.
258520
Calculated by:
KKL
Date:
16 Aug 2010
Sheet No.
Checked by:
AW
Date:
16 Aug 2010
4
Dwg Reference:
OUTPUT

Calculations for:
Rochor Station
Pile Design
REF
CPD-04

Diameter of Pile
Concrete Grade

D
fcu

=
=

800
40

Rebar provided

9 T 20

Dia of link

13 mm

Cover to link

75 mm

Max Com Force


Max Ten Force

Fc
Ft

=
=

mm
N/mm2

2750
500

kN
kN

Design Status:
OK
Spacing of Rebar
211 mm
Percentage Rebar 0.57 %

Max Crack width

0.25

Percentage of reinforcement provided ( 0.5% minimum, 4.0% maximum)


= As/Ac*100
= 0.57 %
OK !

Structural Capacity
** Compression

(CP 4- 7.4.5.3)

Allowable compression capacity for rock socketed reinforced bored cast-in-place


pile with full length of reinforcement is given by;
Fc = [0.4fcuAc + 0.75fyAs]/Fs
Where Fs >= 2 CP4 7.4.5.3
Fs = [0.4fcuAc + 0.75fyAs]/Fc
Fs =

3.26

** Tension
Ultimate Ten Capacity
Tension Crack width
Crack width Location
Spacing of bar

Where

As =
Ac =

> 2, OK !

= 0.57*fy*As
= 741.651 kN

(LTA DC - 6.2.3.9)
> Ft, OK !

(CP 73 - Annex B7)


Co =
S =

53 mm
211 mm

The equation for the crack width under direct tension only is given by,
Wcr
= 3*acr*m
\where,
acr
= 113 mm
m
= 1 - 2*Ac / (3*Es*As)
1
= Ft / (As*Es)
= 0.00088

m
Wcr

=
=

0.00029
0.100 mm

< 0.25, OK !

2828.57 mm2
500029 mm2

Project:

Pile Structural Capacity


Mott MacDonald Singapore
Dvn/Dept:
Structural Job No./File No.
258520
Calculated by:
KKL
Date:
16 Aug 2010
Sheet No.
Checked by:
AW
Date:
16 Aug 2010
5
Dwg Reference:
OUTPUT

Calculations for:
Rochor Station
Pile Design
REF
CPD-05

Diameter of Pile
Concrete Grade

D
fcu

=
=

800
40

Rebar provided

9 T 20

Dia of link

13 mm

Cover to link

75 mm

Max Com Force


Max Ten Force

Fc
Ft

=
=

mm
N/mm2

3400
0

kN
kN

Design Status:
OK
Spacing of Rebar
211 mm
Percentage Rebar 0.57 %

Max Crack width

0.25

Percentage of reinforcement provided ( 0.5% minimum, 4.0% maximum)


= As/Ac*100
= 0.57 %
OK !

Structural Capacity
** Compression

(CP 4- 7.4.5.3)

Allowable compression capacity for rock socketed reinforced bored cast-in-place


pile with full length of reinforcement is given by;
Fc = [0.4fcuAc + 0.75fyAs]/Fs
Where Fs >= 2 CP4 7.4.5.3
Fs = [0.4fcuAc + 0.75fyAs]/Fc
Fs =

2.64

** Tension
Ultimate Ten Capacity
Tension Crack width
Crack width Location
Spacing of bar

Where

As =
Ac =

> 2, OK !

= 0.57*fy*As
= 741.651 kN

(LTA DC - 6.2.3.9)
> Ft, OK !

(CP 73 - Annex B7)


Co =
S =

53 mm
211 mm

The equation for the crack width under direct tension only is given by,
Wcr
= 3*acr*m
\where,
acr
= 113 mm
m
= 1 - 2*Ac / (3*Es*As)
1
= Ft / (As*Es)
=
0

m
Wcr

=
=

-0.00059
-0.2 mm

< 0.25, OK !

2828.57 mm2
500029 mm2

Project:

Pile Structural Capacity


Mott MacDonald Singapore
Dvn/Dept:
Structural Job No./File No.
258520
Calculated by:
KKL
Date:
16 Aug 2010
Sheet No.
Checked by:
AW
Date:
16 Aug 2010
6
Dwg Reference:
OUTPUT

Calculations for:
Rochor Station
Pile Design
REF
CPD-06

Diameter of Pile
Concrete Grade

D
fcu

=
=

800
40

Rebar provided

9 T 20

Dia of link

13 mm

Cover to link

75 mm

Max Com Force


Max Ten Force

Fc
Ft

=
=

mm
N/mm2

4400
0

kN
kN

Design Status:
OK
Spacing of Rebar
211 mm
Percentage Rebar 0.57 %

Max Crack width

0.25

Percentage of reinforcement provided ( 0.5% minimum, 4.0% maximum)


= As/Ac*100
= 0.57 %
OK !

Structural Capacity
** Compression

(CP 4- 7.4.5.3)

Allowable compression capacity for rock socketed reinforced bored cast-in-place


pile with full length of reinforcement is given by;
Fc = [0.4fcuAc + 0.75fyAs]/Fs
Where Fs >= 2 CP4 7.4.5.3
Fs = [0.4fcuAc + 0.75fyAs]/Fc
Fs =

2.04

** Tension
Ultimate Ten Capacity
Tension Crack width
Crack width Location
Spacing of bar

Where

As =
Ac =

> 2, OK !

= 0.57*fy*As
= 741.651 kN

(LTA DC - 6.2.3.9)
> Ft, OK !

(CP 73 - Annex B7)


Co =
S =

53 mm
211 mm

The equation for the crack width under direct tension only is given by,
Wcr
= 3*acr*m
\where,
acr
= 113 mm
m
= 1 - 2*Ac / (3*Es*As)
1
= Ft / (As*Es)
=
0

m
Wcr

=
=

-0.00059
-0.2 mm

< 0.25, OK !

2828.57 mm2
500029 mm2

Project:

Pile Structural Capacity


Mott MacDonald Singapore
Dvn/Dept:
Structural Job No./File No.
258520
Calculated by:
KKL
Date:
16 Aug 2010
Sheet No.
Checked by:
AW
Date:
16 Aug 2010
7
Dwg Reference:
OUTPUT

Calculations for:
Rochor Station
Pile Design
REF
CPD-07

Diameter of Pile
Concrete Grade

D
fcu

=
=

mm
N/mm2

800
40

Rebar provided

= 10 T 20

Dia of link

13 mm

Cover to link

75 mm

Max Com Force


Max Ten Force

Fc
Ft

=
=

4250
750

kN
kN

Design Status:
OK
Spacing of Rebar
190 mm
Percentage Rebar 0.63 %

Max Crack width

0.25

Percentage of reinforcement provided ( 0.5% minimum, 4.0% maximum)


= As/Ac*100
= 0.63 %
OK !

Structural Capacity
** Compression

(CP 4- 7.4.5.3)

Allowable compression capacity for rock socketed reinforced bored cast-in-place


pile with full length of reinforcement is given by;
Fc = [0.4fcuAc + 0.75fyAs]/Fs
Where Fs >= 2 CP4 7.4.5.3
Fs = [0.4fcuAc + 0.75fyAs]/Fc
Fs =

2.14

** Tension
Ultimate Ten Capacity
Tension Crack width
Crack width Location
Spacing of bar

Where

As =
Ac =

> 2, OK !

= 0.57*fy*As
= 824.057 kN

(LTA DC - 6.2.3.9)
> Ft, OK !

(CP 73 - Annex B7)


Co =
S =

53 mm
190 mm

The equation for the crack width under direct tension only is given by,
Wcr
= 3*acr*m
\where,
acr
= 104 mm
m
= 1 - 2*Ac / (3*Es*As)
1
= Ft / (As*Es)
= 0.00119

m
Wcr

=
=

0.00066
0.21 mm

< 0.25, OK !

3142.86 mm2
499714 mm2

Project:

Pile Structural Capacity


Mott MacDonald Singapore
Dvn/Dept:
Structural Job No./File No.
258520
Calculated by:
KKL
Date:
16 Aug 2010
Sheet No.
Checked by:
AW
Date:
16 Aug 2010
8
Dwg Reference:
OUTPUT

Calculations for:
Rochor Station
Pile Design
REF
CPD-08

Diameter of Pile
Concrete Grade

D
fcu

=
=

1000
40

mm
N/mm2

Rebar provided

= 12 T 32

Dia of link

13 mm

Cover to link

75 mm

Max Com Force


Max Ten Force

Fc
Ft

=
=

7850
300

kN
kN

Design Status:
OK
Spacing of Rebar
207 mm
Percentage Rebar 1.24 %

Max Crack width

0.25

Percentage of reinforcement provided ( 0.5% minimum, 4.0% maximum)


= As/Ac*100
= 1.24 %
OK !

Structural Capacity
** Compression

(CP 4- 7.4.5.3)

Allowable compression capacity for rock socketed reinforced bored cast-in-place


pile with full length of reinforcement is given by;
Fc = [0.4fcuAc + 0.75fyAs]/Fs
Where Fs >= 2 CP4 7.4.5.3
Fs = [0.4fcuAc + 0.75fyAs]/Fc
Fs =

2.01

** Tension
Ultimate Ten Capacity
Tension Crack width
Crack width Location
Spacing of bar

Where

As =
Ac =

> 2, OK !

= 0.57*fy*As
2531.5 kN
=

(LTA DC - 6.2.3.9)
> Ft, OK !

(CP 73 - Annex B7)


Co =
S =

53 mm
207 mm

The equation for the crack width under direct tension only is given by,
Wcr
= 3*acr*m
\where,
acr
= 109 mm
m
= 1 - 2*Ac / (3*Es*As)
1
= Ft / (As*Es)
= 0.00016

m
Wcr

=
=

-0.00011
-0.04 mm

< 0.25, OK !

9654.86 mm2
776059 mm2

Project:

Pile Structural Capacity


Mott MacDonald Singapore
Dvn/Dept:
Structural Job No./File No.
258520
Calculated by:
KKL
Date:
16 Aug 2010
Sheet No.
Checked by:
AW
Date:
16 Aug 2010
9
Dwg Reference:
OUTPUT

Calculations for:
Rochor Station
Pile Design
REF
CPD-09

Diameter of Pile
Concrete Grade

D
fcu

=
=

800
40

Rebar provided

9 T 20

Dia of link

13 mm

Cover to link

75 mm

Max Com Force


Max Ten Force

Fc
Ft

=
=

mm
N/mm2

3300
600

kN
kN

Design Status:
OK
Spacing of Rebar
211 mm
Percentage Rebar 0.57 %

Max Crack width

0.25

Percentage of reinforcement provided ( 0.5% minimum, 4.0% maximum)


= As/Ac*100
= 0.57 %
OK !

Structural Capacity
** Compression

(CP 4- 7.4.5.3)

Allowable compression capacity for rock socketed reinforced bored cast-in-place


pile with full length of reinforcement is given by;
Fc = [0.4fcuAc + 0.75fyAs]/Fs
Where Fs >= 2 CP4 7.4.5.3
Fs = [0.4fcuAc + 0.75fyAs]/Fc
Fs =

2.72

** Tension
Ultimate Ten Capacity
Tension Crack width
Crack width Location
Spacing of bar

Where

As =
Ac =

> 2, OK !

= 0.57*fy*As
= 741.651 kN

(LTA DC - 6.2.3.9)
> Ft, OK !

(CP 73 - Annex B7)


Co =
S =

53 mm
211 mm

The equation for the crack width under direct tension only is given by,
Wcr
= 3*acr*m
\where,
acr
= 113 mm
m
= 1 - 2*Ac / (3*Es*As)
1
= Ft / (As*Es)
= 0.00106

m
Wcr

=
=

0.00047
0.16 mm

< 0.25, OK !

2828.57 mm2
500029 mm2

Project:

Pile Structural Capacity


Mott MacDonald Singapore
Dvn/Dept:
Structural Job No./File No.
258520
Calculated by:
KKL
Date:
16 Aug 2010
Sheet No.
Checked by:
AW
Date:
16 Aug 2010
10
Dwg Reference:
OUTPUT

Calculations for:
Rochor Station
Pile Design
REF
CPD-10

Diameter of Pile
Concrete Grade

D
fcu

=
=

1000
40

mm
N/mm2

Rebar provided

= 13 T 20

Dia of link

13 mm

Cover to link

75 mm

Max Com Force


Max Ten Force

Fc
Ft

=
=

6050
0

kN
kN

Design Status:
OK
Spacing of Rebar
194 mm
Percentage Rebar 0.52 %

Max Crack width

0.25

Percentage of reinforcement provided ( 0.5% minimum, 4.0% maximum)


= As/Ac*100
= 0.52 %
OK !

Structural Capacity
** Compression

(CP 4- 7.4.5.3)

Allowable compression capacity for rock socketed reinforced bored cast-in-place


pile with full length of reinforcement is given by;
Fc = [0.4fcuAc + 0.75fyAs]/Fs
Where Fs >= 2 CP4 7.4.5.3
Fs = [0.4fcuAc + 0.75fyAs]/Fc
Fs =

2.30

** Tension
Ultimate Ten Capacity
Tension Crack width
Crack width Location
Spacing of bar

Where

As =
Ac =

> 2, OK !

= 0.57*fy*As
= 1071.27 kN

(LTA DC - 6.2.3.9)
> Ft, OK !

(CP 73 - Annex B7)


Co =
S =

53 mm
194 mm

The equation for the crack width under direct tension only is given by,
Wcr
= 3*acr*m
\where,
acr
= 106 mm
m
= 1 - 2*Ac / (3*Es*As)
1
= Ft / (As*Es)
=
0

m
Wcr

=
=

-0.00064
-0.2 mm

< 0.25, OK !

4085.71 mm2
781629 mm2

Project:

Pile Structural Capacity


Mott MacDonald Singapore
Dvn/Dept:
Structural Job No./File No.
258520
Calculated by:
KKL
Date:
16 Aug 2010
Sheet No.
Checked by:
AW
Date:
16 Aug 2010
11
Dwg Reference:
OUTPUT

Calculations for:
Rochor Station
Pile Design
REF
CPD-11

Diameter of Pile
Concrete Grade

D
fcu

=
=

800
40

Rebar provided

9 T 20

Dia of link

13 mm

Cover to link

75 mm

Max Com Force


Max Ten Force

Fc
Ft

=
=

mm
N/mm2

3000
0

kN
kN

Design Status:
OK
Spacing of Rebar
211 mm
Percentage Rebar 0.57 %

Max Crack width

0.25

Percentage of reinforcement provided ( 0.5% minimum, 4.0% maximum)


= As/Ac*100
= 0.57 %
OK !

Structural Capacity
** Compression

(CP 4- 7.4.5.3)

Allowable compression capacity for rock socketed reinforced bored cast-in-place


pile with full length of reinforcement is given by;
Fc = [0.4fcuAc + 0.75fyAs]/Fs
Where Fs >= 2 CP4 7.4.5.3
Fs = [0.4fcuAc + 0.75fyAs]/Fc
Fs =

2.99

** Tension
Ultimate Ten Capacity
Tension Crack width
Crack width Location
Spacing of bar

Where

As =
Ac =

> 2, OK !

= 0.57*fy*As
= 741.651 kN

(LTA DC - 6.2.3.9)
> Ft, OK !

(CP 73 - Annex B7)


Co =
S =

53 mm
211 mm

The equation for the crack width under direct tension only is given by,
Wcr
= 3*acr*m
\where,
acr
= 113 mm
m
= 1 - 2*Ac / (3*Es*As)
1
= Ft / (As*Es)
=
0

m
Wcr

=
=

-0.00059
-0.2 mm

< 0.25, OK !

2828.57 mm2
500029 mm2

Project:

Pile Structural Capacity


Mott MacDonald Singapore
Dvn/Dept:
Structural Job No./File No.
258520
Calculated by:
KKL
Date:
16 Aug 2010
Sheet No.
Checked by:
AW
Date:
16 Aug 2010
12
Dwg Reference:
OUTPUT

Calculations for:
Rochor Station
Pile Design
REF
CPD-12

Diameter of Pile
Concrete Grade

D
fcu

=
=

800
40

Rebar provided

9 T 20

Dia of link

13 mm

Cover to link

75 mm

Max Com Force


Max Ten Force

Fc
Ft

=
=

mm
N/mm2

2850
500

kN
kN

Design Status:
OK
Spacing of Rebar
211 mm
Percentage Rebar 0.57 %

Max Crack width

0.25

Percentage of reinforcement provided ( 0.5% minimum, 4.0% maximum)


= As/Ac*100
= 0.57 %
OK !

Structural Capacity
** Compression

(CP 4- 7.4.5.3)

Allowable compression capacity for rock socketed reinforced bored cast-in-place


pile with full length of reinforcement is given by;
Fc = [0.4fcuAc + 0.75fyAs]/Fs
Where Fs >= 2 CP4 7.4.5.3
Fs = [0.4fcuAc + 0.75fyAs]/Fc
Fs =

3.15

** Tension
Ultimate Ten Capacity
Tension Crack width
Crack width Location
Spacing of bar

Where

As =
Ac =

> 2, OK !

= 0.57*fy*As
= 741.651 kN

(LTA DC - 6.2.3.9)
> Ft, OK !

(CP 73 - Annex B7)


Co =
S =

53 mm
211 mm

The equation for the crack width under direct tension only is given by,
Wcr
= 3*acr*m
\where,
acr
= 113 mm
m
= 1 - 2*Ac / (3*Es*As)
1
= Ft / (As*Es)
= 0.00088

m
Wcr

=
=

0.00029
0.1 mm

< 0.25, OK !

2828.57 mm2
500029 mm2

Project:

Pile Structural Capacity


Mott MacDonald Singapore
Dvn/Dept:
Structural Job No./File No.
258520
Calculated by:
KKL
Date:
16 Aug 2010
Sheet No.
Checked by:
AW
Date:
16 Aug 2010
13
Dwg Reference:
OUTPUT

Calculations for:
Rochor Station
Pile Design
REF
CPD-13

Diameter of Pile
Concrete Grade

D
fcu

=
=

1000
40

mm
N/mm2

Rebar provided

= 13 T 20

Dia of link

13 mm

Cover to link

75 mm

Max Com Force


Max Ten Force

Fc
Ft

=
=

5450
200

kN
kN

Design Status:
OK
Spacing of Rebar
194 mm
Percentage Rebar 0.52 %

Max Crack width

0.25

Percentage of reinforcement provided ( 0.5% minimum, 4.0% maximum)


= As/Ac*100
= 0.52 %
OK !

Structural Capacity
** Compression

(CP 4- 7.4.5.3)

Allowable compression capacity for rock socketed reinforced bored cast-in-place


pile with full length of reinforcement is given by;
Fc = [0.4fcuAc + 0.75fyAs]/Fs
Where Fs >= 2 CP4 7.4.5.3
Fs = [0.4fcuAc + 0.75fyAs]/Fc
2.55

Fs =

** Tension
Ultimate Ten Capacity
Tension Crack width
Crack width Location
Spacing of bar

Where

As =
Ac =

> 2, OK !

= 0.57*fy*As
= 1071.27 kN

(LTA DC - 6.2.3.9)
> Ft, OK !

(CP 73 - Annex B7)


Co =
S =

53 mm
194 mm

The equation for the crack width under direct tension only is given by,
Wcr
= 3*acr*m
\where,
acr
= 106 mm
m
= 1 - 2*Ac / (3*Es*As)
1
= Ft / (As*Es)
= 0.00024

m
Wcr

=
=

-0.00039
-0.12 mm

< 0.25, OK !

4085.71 mm2
781629 mm2

Project:

Pile Structural Capacity


Mott MacDonald Singapore
Dvn/Dept:
Structural Job No./File No.
258520
Calculated by:
KKL
Date:
16 Aug 2010
Sheet No.
Checked by:
AW
Date:
16 Aug 2010
14
Dwg Reference:
OUTPUT

Calculations for:
Rochor Station
Pile Design
REF
CPD-14

Diameter of Pile
Concrete Grade

D
fcu

=
=

800
40

Rebar provided

9 T 20

Dia of link

13 mm

Cover to link

75 mm

Max Com Force


Max Ten Force

Fc
Ft

=
=

mm
N/mm2

2700
450

kN
kN

Design Status:
OK
Spacing of Rebar
211 mm
Percentage Rebar 0.57 %

Max Crack width

0.25

Percentage of reinforcement provided ( 0.5% minimum, 4.0% maximum)


= As/Ac*100
= 0.57 %
OK !

Structural Capacity
** Compression

(CP 4- 7.4.5.3)

Allowable compression capacity for rock socketed reinforced bored cast-in-place


pile with full length of reinforcement is given by;
Fc = [0.4fcuAc + 0.75fyAs]/Fs
Where Fs >= 2 CP4 7.4.5.3
Fs = [0.4fcuAc + 0.75fyAs]/Fc
Fs =

3.32

** Tension
Ultimate Ten Capacity
Tension Crack width
Crack width Location
Spacing of bar

Where

As =
Ac =

> 2, OK !

= 0.57*fy*As
= 741.651 kN

(LTA DC - 6.2.3.9)
> Ft, OK !

(CP 73 - Annex B7)


Co =
S =

53 mm
211 mm

The equation for the crack width under direct tension only is given by,
Wcr
= 3*acr*m
\where,
acr
= 113 mm
m
= 1 - 2*Ac / (3*Es*As)
1
= Ft / (As*Es)
0.0008
=

m
Wcr

=
=

0.00021
0.07 mm

< 0.25, OK !

2828.57 mm2
500029 mm2

Project:

Pile Structural Capacity


Mott MacDonald Singapore
Dvn/Dept:
Structural Job No./File No.
258520
Calculated by:
KKL
Date:
16 Aug 2010
Sheet No.
Checked by:
AW
Date:
16 Aug 2010
15
Dwg Reference:
OUTPUT

Calculations for:
Rochor Station
Pile Design
REF
CPD-15

Diameter of Pile
Concrete Grade

D
fcu

=
=

800
40

Rebar provided

9 T 20

Dia of link

13 mm

Cover to link

75 mm

Max Com Force


Max Ten Force

Fc
Ft

=
=

mm
N/mm2

3500
0

kN
kN

Design Status:
OK
Spacing of Rebar
211 mm
Percentage Rebar 0.57 %

Max Crack width

0.25

Percentage of reinforcement provided ( 0.5% minimum, 4.0% maximum)


= As/Ac*100
= 0.57 %
OK !

Structural Capacity
** Compression

(CP 4- 7.4.5.3)

Allowable compression capacity for rock socketed reinforced bored cast-in-place


pile with full length of reinforcement is given by;
Fc = [0.4fcuAc + 0.75fyAs]/Fs
Where Fs >= 2 CP4 7.4.5.3
Fs = [0.4fcuAc + 0.75fyAs]/Fc
2.56

Fs =

** Tension
Ultimate Ten Capacity
Tension Crack width
Crack width Location
Spacing of bar

Where

As =
Ac =

> 2, OK !

= 0.57*fy*As
= 741.651 kN

(LTA DC - 6.2.3.9)
> Ft, OK !

(CP 73 - Annex B7)


Co =
S =

53 mm
211 mm

The equation for the crack width under direct tension only is given by,
Wcr
= 3*acr*m
\where,
acr
= 113 mm
m
= 1 - 2*Ac / (3*Es*As)
1
= Ft / (As*Es)
0
=

m
Wcr

=
=

-0.00059
-0.2 mm

< 0.25, OK !

2828.57 mm2
500029 mm2