1. Scope
1.1 This test method covers the determination of unsaponifiable matter in alkyd resins and resin solutions. This test
method is not applicable to alkyd resins containing modifying
agents such as urea, melamine, phenols, rosin, and styrene.
1.2 This standard does not purport to address all of the
safety concerns, if any, associated with its use. It is the
responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For a specific
hazard statement, see Note 4.
Steam Bath.
Vacuum Drying OvenA small, laboratory-size vacuum
thermostatically controlled to operate at 80 6 5C. A
aspirator vacuum source is satisfactory.
2. Referenced Documents
2.1 ASTM Standards:
D 1193 Specification for Reagent Water2
3. Significance and Use
3.1 The unsaponifiable matter in alkyd resins controls the
properties of the final film.
4. Apparatus
4.1 Aluminum Beaker, having a capacity of 125 mL.3
4.2 Flask and CondenserA 200-mL Erlenmeyer flask
fitted with a water-cooled glass reflux condenser. The connection between the flask and condenser shall be a standard 24/40
taper ground-glass joint.
4.3 Separatory FunnelsThree 500-mL capacity fitted with
standard-taper, ground-glass stoppers and stopcocks. Stopcocks should be lubricated sparingly with ether-insoluble
stopcock grease. Alternatively, funnels fitted with tetrafluoroethylene (TFE-fluorocarbon) stopcocks may be used.
1
This test method is under the jurisdiction of ASTM Committee D-1 on Paint
and Related Coatings, Materials, and Applications and is the direct responsibility of
Subcommittee D01.33 on Polymers and Resins.
Current edition approved April 15, 1993. Published June 1993. Originally
published as D 1397 56 T. Last previous edition D 1397 88.
2
Annual Book of ASTM Standards, Vol 11.01.
3
Aluminum beakers, Catalog No. 2100, manufactured by the A. H. Thomas Co.,
W. Washington Square, Philadelphia, PA 19105, have been found satisfactory for
this purpose.
4
Reagent Chemicals, American Chemical Society Specifications, American
Chemical Society, Washington, DC. For suggestions on the testing of reagents not
listed by the American Chemical Society, see Analar Standards for Laboratory
Chemicals, BDH Ltd., Poole, Dorset, U.K., and the United States Pharmacopeia
and National Formulary, U.S. Pharmacopeial Convention, Inc. (USPC), Rockville,
MD.
Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
D 1397 93 (1998)
5.10 Sodium Hydroxide, Standard Solution (0.02 N)
Prepare and accurately standardize a 0.02 N aqueous NaOH
solution.
6. Procedure
6.1 Weigh by difference, from a closed container into the
200-mL Erlenmeyer flask, a portion of resin or resin solution
containing from 0.05 to 0.2 g of unsaponifiable matter (Note 1)
(8 to 10 g of resin solution usually is sufficient).
NOTE 1The maximum specimen size is limited to 10 g of nonvolatile
matter; otherwise saponification or separation difficulties may arise. The
specimen should be weighed to the nearest milligram.
F 5 VN 3 0.280
(1)
where:
F
= fatty acids in extract, g,
V
= NaOH solution required for titration of the residue,
mL,
N
= normality of the NaOH solution, and
0.280 = the factor used for normal 18-carbon atom fatty
acids. If coconut, lauric, pelargonic, or other short
chain fatty acids are suspected or known to be
present, use the arbitrary factor 0.216 in the above
equation.
U 5 [~R 2 F!/S] 3 100
(2)
where:
U = unsaponifiable matter,% ,
R = residue, g, and
S = specimen, g.
8. Precision and Bias
8.1 On the basis of an interlaboratory study of this test
method in which the within-laboratory standard deviation was
found to be 0.08 % absolute and the between-laboratory
standard deviation was found to be 0.11 % absolute the
following criteria should be used for judging the acceptability
of results at the 95 % confidence level:
8.1.1 RepeatabilityTwo results, each the mean of duplicate determinations, obtained by the same operator, should be
considered suspect if they differ by more than 0.25 % absolute.
8.1.2 ReproducibilityTwo results, each the mean of duplicate determinations, obtained by operators in different laboratories, should be considered suspect if they differ by more than
0.33 % absolute.
8.2 BiasNo bias can be determined for this test method
since no standard alkyd resin exists.
NOTE 2If the layers do not separate easily, carefully draw off the
lower, clear, aqueous layer and add 2 to 3 mL of alcohol, by means of a
pipet, to the ether-emulsion phases in the separatory funnel. Swirl gently
to break the emulsion, and continue to draw off the lower layer. This
procedure for breaking the emulsion may be repeated on subsequent
extractions, if necessary.
9. Keywords
9.1 alcohol benzene solution; alkyd resin; alkyd resin solution; coconut acid; lauric acid; pelargonic acid
NOTE 3The metal top of the steam bath should be covered with clean
aluminum foil to prevent corrosion of the aluminum beaker during the
evaporation.
D 1397 93 (1998)
ASTM International takes no position respecting the validity of any patent rights asserted in connection with any item mentioned
in this standard. Users of this standard are expressly advised that determination of the validity of any such patent rights, and the risk
of infringement of such rights, are entirely their own responsibility.
This standard is subject to revision at any time by the responsible technical committee and must be reviewed every five years and
if not revised, either reapproved or withdrawn. Your comments are invited either for revision of this standard or for additional standards
and should be addressed to ASTM International Headquarters. Your comments will receive careful consideration at a meeting of the
responsible technical committee, which you may attend. If you feel that your comments have not received a fair hearing you should
make your views known to the ASTM Committee on Standards, at the address shown below.
This standard is copyrighted by ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959,
United States. Individual reprints (single or multiple copies) of this standard may be obtained by contacting ASTM at the above
address or at 610-832-9585 (phone), 610-832-9555 (fax), or service@astm.org (e-mail); or through the ASTM website
(www.astm.org).