You are on page 1of 4

Empty Enclosure

Series 8250
> Cost effective single enclosure

E3

> Lightweight construction


> Temperature range for
worldwide use

E3

> Retrofittable hinges

E3
E3

www.stahl.de

E3
E3
Series 8250 E3

16087E00

E3

The enclosure is used to build motor control units, control stations


and terminal boxes with type of protection "Ex d". It is suitable for
the installation of customer-specific control panels.
The enclosure allows installation and operation of arcing equipment
in Zones 1, 2, 21 and 22.
For direct cable entry into the enclosures, flameproof cable glands
with type of protection Ex d or threaded holes for conduit connection
can be applied.

E3
E3

ATEX / IECEx
Zone
For use in

20

21

22

E3
E3
E3
E3

WebCode 8250A
2014-10-22EK00IIIen

E3
Installation Equipment

E3/1

Empty Enclosure
Series 8250
Selection Table
Version

Description

Order number

Weight

Empty enclosure without holes

8250/0-0250-0150110-210031

6.540

Empty enclosure with holes (see list of dimensional drawings)

8250/1-0250-0150110-210231

6.540

Empty enclosure without holes

8250/0-0300-0230125-210031

10.500

Empty enclosure with holes (see list of dimensional drawings)

8250/1-0300-0230125-210231

10.500

kg

Enclosure size 1

Enclosure size 1

Enclosure size 2

Enclosure size 2

E3/2

16089E00

16092E00

16088E00

16093E00

Installation Equipment

2014-10-22EK00IIIen

Empty Enclosure
Series 8250
Technical Data
Explosion protection
Global (IECEx)
Gas and dust

Europe (ATEX)
Gas and dust

Certifications and certificates


Certificates
Electrical data
Protective conductor
connection
Ambient conditions
Ambient temperature
range
with actuation axis,
coupler, inspection
window
Storage temperature
Limit temperature
enclosure material
Relative humidity
(no condensation)
Use at the height of
Mechanical data
Enclosure material
Seal
Degree of protection
Cover lock
Hinges
Wall mounting

E3
IECEx BVS 13.0067U
Ex d IIB T4-T6 Gb
Ex tb IIIC T80C - T130C Db

E3

BVS 13 ATEX E057U


E II 2G Ex d IIB T4-T6 Gb
E II 2 D Ex tb IIIC T80C - T130C Db

E3

IECEx, ATEX, India (PESO)


inside/outside on the enclosure (threaded holes), M8 threaded screw
Tightening torque: 2.8 Nm

E3

-60 ... +70 C

E3

-55 ... +55 C


-60 ... +80 C
LM25:

130 C

E3

95 %
< 2000 m (others on request)
LM 25, coated/not coated
Silicone O-ring
IP65, IP66 according to IEC/EN 60529 (with additional O-ring)
(optional: captive) M8 stainless steel allen screws, tightening torque M8 = 12 Nm, M10 = 18 Nm
optional with cover hinges,
enclosure cover opening angle > 180
using a mounting bracket (accessories) or directly into the enclosure base

E3
E3
E3
E3
E3
E3
E3
E3

2014-10-22EK00IIIen

Installation Equipment

E3/3

Empty Enclosure
Series 8250
Dimensional Drawings (All Dimensions in mm [inches]) - Subject to Alterations)
225 [8,86]
150 [5,91]

75 [ 2,95]

250 [9,84]
325 [12,80]

86 [ 3,39]

56

M20 x 1,5
M25 x 1,5
3 [0,12]

225
[8,86]

10 [0,39]

M32 x 1,5

50 [1,97]

16133E00

8250/1-0250-150-110-210231
Size 1 with holes
298 [11,73]

86 [ 3,39]

M32 x 1,5
M40 x 1,5

298
[11,73]

62
[2,44]

70
[2,76]

E3/4

Installation Equipment

65 [2,56]
20 [0,79]

B
45 [1,77]

16091E00

8250/0-0300-0230-125-..21..
Size 2 without holes

300 [11,81]
368 [14,49]

[2,95]

75
8

M25 x 1,5

41
[1,61]

M20 x 1,5

[0,32]

35
[1,38]

85 [ 3,35]

368 [14,49]

55
[2,17]

125 [4,92]

300 [11,81]
250 [9,84]

M8 x 8
[M8 x 0,31]

110 [4,33] 115 [4,53]

152 [5,98]

115 [4,53]

230 [9,06]

14
[0,55]

230 [9,06]

41
[1,61]

60

8250/0-0250-150-110-..21..
Size 1 without holes

230 [9,06]

40 [1,57]

16090E00

[2,36]

14
[0,55]

30 [1,18]

[1,42]

36

77
[3,03]

62
[2,44]
75 [ 2,95]

[2,20]

46 [ 1,81]

46
[1,81]

110 [4,33]

250 [9,84]
210 [8,27]

325 [12,80]

18 [ 0,71]

98 [3,86]
58
[2,28]

M8 x 8
[M8 x 0,31]

91 [3,58]

150 [5,91]

36
[1,42]

25
[0,98]

131 [5,16]

100 [3,94]

150 [5,91]

16134E00

8250/1-0300-0230-125-210231
Size 2 with holes

2014-10-22EK00IIIen