Boilerfeedpumpsareanimportantpartofany
boileroperation.Theycontroltheamountofwater
fedtotheboilerandthemannerinwhichitisfed.
BoilerSales
AjaxBoiler
HurstBoiler
CentrifugalContinuous
TurbineIntermittent
PrecisionBoiler
Inordertoproperlyselectaboilerfeedpumpfive
keypointsmustbeconsidered:
Deaerator
Willthepumpsoperationbecontinuousorintermittent?
Burners
Thisisanoperationalquestionandisoftenansweredbythetypeoflevelcontrol
foundontheboilerthatthepumpwillbeservicing.Asageneralruleofthumb,
boilerswithacapacityof10,000lbs./hr.orlessutilizeafloattypeswitchthatstarts
andstopstheboilerfeedpumptosatisfyapredeterminedwaterlevelwithinthe
boiler.Thisisaclassicintermittentoperation.
BoilerQuestions
BoilerTips
BoilerStartup
Boilerswithcapacitiesexceeding10,000lb./hr.typicallyemploysamodulatingfeed
waterregulatorandwillcontinuouslyfeedwatertotheboileratvariousrates
BoilerRoomAccessories dependinguponthewaterlevelintheboiler.
BoilerProjects
BoilerParts
AxelsonReliefvalves
AmotValves
MicroturbineSales
Byknowingwhichoperationyouaretosatisfy,youcandeterminewhichpump
designisbestsuitedforyourapplication.Asageneralruleofthumbaturbinepump
isusedinanonoffsituationandacentrifugalpumpisusedforcontinuousoperation.
Butremember,thisisageneralruleandissomecasesacentrifugalcouldbeusedfor
anonoffapplicationandaturbineforcontinuous.
Whatisthetemperatureofthewaterbeingpumped?
Itisalsoimportanttoknowthetemperatureofwateryouintendtopump.Most
pumpscanusuallyhandle215oFto230oF,otherpumpsareavailablethatcan
handlehighertemperaturesbyusingexternalwatercooling.Keepinmindthata
deaeratorpumpmustbeabletohandlehighertemperaturesbecausetheyoperatea5
psior227oF.
Whatistherequiredcapacity?
Howmuchwateryouintendtopumpisdependentupontheevaporationrateofthe
boilerthepumpwillservice.Asafefigureforanonoffapplicationwouldbe2times
theevaporationrateoftheboiler.Withamodulatinglevelcontrol,afactorof1.3
timestheevaporationrateplusrecirculationisrecommended.
Whatisthedesireddischargepressure?
Whenyoupumpdirectlyintotheboileryouwillneedtoovercomethepressureinthe
boileraswellasanypipinglosses.Youcanchosetherightpumpbylookingatthe
pumpcurvestodeterminewhichwillaccomplishthistask.Shouldyouhavea
modulatingvalveinthedischargeline,theminimumyouwillneedtoaddtothe
boileroperatingpressurewillbe20to25lbs.Makesurethatthepumpcanhandlethe
pressurealongwiththeflowrateneeded.Withanonofflevelcontrolthepumps
shouldbedesignedforthereliefvalvepressure.
WhatistheNPSHornetpositivesuctionheadrequired?
Thisisthelastpieceofinformationthatyouwillneed.Thisistheminimumabsolute
pressureatthesuctionnozzleatwhichthepumpcanoperate.Toavoidpump
cavitation,theNPSHAofthesystemmustbegreaterthantheNPSHRofthepump.
Inotherwords,theavailableNPSHmustbehigherthantherequired.Wehavealways
http://www.mckenziecorp.com/boiler_tip_12.htm
1/2
11/17/2016
boilerfeedpumpsfindinformationforallfeedpumps
sizedourdeaeratorstandstobetwofeethigherthantheNPSHneededforthepump
selection.Remember,thewaterlevelinthestoragetankaddstothesafetymargin.
VisitourBoilerPumpsPageformoreinformation.
Readmoreaboutpumpmaintenance.
PutyourBoilerintoStorage
WaterhardnessinBoilers
BuyingaBoiler
GettingyourBoilerreadyforwinter
Watertubevs.Firetube
BoilerWaterQuality
BoilerMaintenance
BoilerMaintenanceCheckList
BoilerFiresideCare
BoilerRoomSupportEquipment
BoilerBlowdown
BoilerRefractoryCare
CombustionAirFan
AutomatedChimneyVentingSystems
AddressingAlkalinity
PropersizingofBoilerFeedwaterSystems
BoilerFeedPumps
DeaerationofBoilerFeedwater
Properuseandcareforboilergageglass
OurBoilerPartsDepartment
Don'tforgettostopbyandvisitourboilerpartsdepartment.Wearetheexpertswhen
itcomestofindingthose"hardtofind"parts.
MAILING:
PHONE:
SHIPPING:
P.C.McKenzieCompany
P.O.Box112638
Pittsburgh,PA15241
18772444883
Fax:4122578890
Phone:4122578866
P.C.McKenzieCompany
1365McLaughlinRunRoad
Pittsburgh,PA15241
http://www.mckenziecorp.com/boiler_tip_12.htm
2/2