THINKING AHEAD

Conventional
Fire Detection and Alarm System
Zone 3

In case of FIRE
lift the lid
press for alarm

FIRE

Zone 4
Zone 2

In case of FIRE
lift the lid
press for alarm

FIRE

In case of FIRE
lift the lid
press for alarm

FIRE

Zone 1
SOUNDER BEACON

In case of FIRE
lift the lid
press for alarm

FIRE

CALL POINT

DETECTOR

ISOLATE
SYSTEM ON
AC FAIL
CHARGER ON
LOW BATTERY

FIRE

FAULT

1
2
2
3
3

4
4

NO BATTERY
SILENCE

LAMP TEST

RESET

A L C A P 401 Z

CONTROL PANEL

Conventional Fire Detection and Alarm System offer a good basic system, ideal for
small applications or projects on a tight budget. The detectors and call points in a
zone (or area) of the building are all connected to the same pair of wires. The
sounders are wired on a separate circuit. If any of the devices reports an alarm, panel
buzzer sound and LED indications are shown on the control panel.
This Conventional System contains its own integral power supply and battery
support, alarm sounder circuits, providing auto isolate zone when short circuit
occurs, lamp test facility, simplified system design and installation. Control panel &
devices tend to be cheaper, simple setup, no configuration required and wide range
of compatibility between manufacturers.

ACSC - V.01 - 05.02.2015

www.airlight.in

THINKING AHEAD

Conventional
Fire Detection and Alarm System

AC103SD
Optical Smoke Detector

AC103HD
Heat Detector

AC103LPG

AC103MD
Multisensor

Gas Leak Detector

AC103SCI

Response Indicator

In case of FIRE
lift the lid
press for alarm

FIRE

AC104SB

AC104CP
Manual Call Point

Sounder Beacon

AC103WCP
Weather Proof
Call Point

AC103FCP
Flame Proof
Call Point

ISOLATE

ISOLATE
SYSTEM ON
AC FAIL

FIRE

FAULT

ISOLATE

SYSTEM ON

2
2

AC FAIL

CHARGER ON

CHARGER ON
LOW BATTERY

LOW BATTERY

NO BATTERY
SILENCE

LAMP TEST

RESET

AC FAIL

2
3
4

NO BATTERY

FIRE

FAULT

SILENCE

LAMP TEST

RESET

FAULT
S
O

1
2
2
3
3

FIRE

A L C A P 801 Z

1
2
3
4
5
6
7
8

4
4

NO BATTERY

A L C A P 201 Z

SYSTEM ON

CHARGER ON
LOW BATTERY

SILENCE

LAMP TEST

RESET

A L C A P 401 Z

ALCAP201Z

ALCAP401Z

ALCAP801Z

Conventional 2 Zone
Fire Alarm Panel

Conventional 4 Zone
Fire Alarm Panel

Conventional 8 Zone
Fire Alarm Panel

ISOLATE
SYSTEM ON

AC FAIL

CHARGER ON

FAULT
S
O

FIRE

A L C A P1201 Z

1
2

LOW BATTERY

NO BATTERY

5
6
7
8
9

SILENCE

10

LAMP TEST

11

RESET

12

3
4
5
6
7
8
9
10
11
12

ALCAP1201Z

Conventional 12 Zone
Fire Alarm Panel

ACSC - V.01 - 05.02.2015

www.airlight.in