Professional Documents
Culture Documents
Australia
Canada
Congo
Cyprus
Egypt
Europe
Ghana
Iran
Iraq
Jordan
Kenya
Kuwait
Libya
Malaysia
Mauritius
New Zealand
Nigeria
Oman
Qatar
Rwanda
Saudi Arabia
South Africa
South Korea
Sri Lanka
Sudan
Syria
Tanzania
U.A.E.
U.K.
Uganda
Zambia
E-mail : exports@polycab.com
Website : www.polycab.com
PRODUCT RANGE
BRAIDED CABLES
THERMOCOUPLE / COMPENSATING CABLES
SOLAR AC / DC CABLES
TELEPHONE CABLES
PANEL BOARD WIRES
CO-AXIAL CABLES
LAN CABLES
SUBMERSIBLE CABLES
RAILWAY SIGNALLING CABLES
M.V. / L.V. AERIAL BUNCHED CABLES
SPECIALITY CABLES
Suited for Marine / Oil & Gas / Extreme Fire conditions /
Highly corrosive environment / Traffic / Aircraft /
Space Station / Automobiles.
Competitive prices
Consistent quality
Timely delivery
Product development for a changing market
A targeted stocking policy
Technical Support for Applications / Projects
Turnover
1050
(US $ in Million)
65.00
845
58.00
51.00
735
42.00
46.00
582
507
08-09
09-10
10-11
11-12
12-13
eStIMAted
Projected
08-09
09-10
10-11
PROJECTED
11-12
PROJECTED
12-13
QualItY PeOPle
No quality is possible without the right people to carry through on the program. Everyone, from administrative
staff to expert engineers, are committed to constant improvement. This commitment is backed by intensive
training and education within an environment of Trust, Respect, Participation and Recognition.
mISSIOn
VISIOn
QualItY POlIcY
aPPROValS
WE ARE APPROVED BY ALL THE MAJOR CONSULTANTS / SPECIFIERS LIKE :
4
l
l
l
l
l
l
l
l
l
l
AKER KVAERNER
AVANT GARDE
BECHTEL LTD., U.K.
DESEIN
EIL
FITCHNER
GHERZI EASTERN
HOLTEC
JACOBS H & G
LURGI
l
l
l
l
l
l
l
l
l
l
M.N. DASTUR
MECON
MOTT MCDONALD
PDIL
SAIPEM TRIUNE
SPECTRAL
TCE
TECHNIMONT ICB
TOYO ENGG.
UHDE INDIA
KEMA
BVIS
CEIL
CPRI
DNV
ERDA
IRS
l
l
l
l
l
BASEC
LLOYDS
MECON
RITES
SGS
TUV
l
l
l
l
ABB
ALSTOM
BAJAJ ELECTRICALS
BHEL
CCC
CROMPTON GREAVES
DAELIM
DODSAL ENGINEERING
G.S. ENGINEERING
GE OIL & GAS
GE POWER
HYUNDAI
IRCON
J RAY MCDERMOTT
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
JYOTI STRUCTURES
KAZSTROY
LARSEN & TOUBRO
LINDE ENGINEERING
NPCC
PETROFAC
PUNJ LLOYD
RELIANCE ENERGY
SAMSUNG
SIEMENS
TATA PROJECTS
TECHNIMONT
TECHNIP
THERMAX
UB ENGG
aPPROValS
PETROLEUM
1. PRESTIGIOUS BROWN FIELD PROJECT AT ABU DHABI
FOR BOROUGE RUWAIS 2 PROJECT, SUPPLIED 2960
KMS OF INSTRUMENTATION CABLES THROUGH EPC
CONTRACTOR LINDE ENGINEERING GERMANY
2. PRESTIGIOUS BROWN FIELD PROJECT BEING
BUILT FOR PETROLEUM DEVELOPMENT OF OMAN,
SUPPLIED 60 KMS OF MV CABLES FOR QARN ALAM
PROJECT THROUGH DODSAL ENGINEERING FOR
VARIOUS APPLICATIONS IN MENTIONED PROJECT
3. PRESTIGIOUS BROWN FIELD PROJECT BEING
BUILT FOR HINDUSTAN PETROLEUM CORPORATION
LIMITED= - MUMBAI. FOR THEIR GREEN FUEL &
EMISSION CONTROL PROJECT, EXECUTED 1820
KM OF MV CABLES OF HT, LV, POWER, CONTROL &
INSTRUMENTATION CABLE ORDERS
4. PRESTIGIOUS GREEN FIELD REFINERY PROJECT
BUILT FOR BHARAT OMAN REFINERY LTD, THROUGH
EIL. SUPPLIED 1163KMS OF HT, LV, POWER,
CONTROL & INSTRUMENTATION CABLE ORDERS
STEEL
1. PRESTIGIOUS BROWN FIELD PROJECT OF AL
GHURAIR IRON & STEEL L.L.C., ABU DHABI, U.A.E
SUPPLIED 350KMS OF LV, MV CABLE ORDERS
CEMENT
Nominal area of
conductor
Nominal Insulation
Thickness
Maximum overall
diameter
Approximate
weight
(mm)
(mm)
(mm)
(kg/km)
1.5
0.7
3.3
21
2.5
0.8
4.0
32
Insulation: PVC
0.8
4.6
47
Voltage: 450/750 V
Code: HO7V-R
0.8
5.2
67
10
1.0
6.7
110
16
1.0
7.8
165
Note :
1) Above data is approximate and subject
to manufacture tolerance.
25
1.2
9.7
260
35
1.2
10.9
350
50
1.4
12.8
475
70
1.4
14.6
660
95
1.6
17.1
910
120
1.6
18.8
1140
150
1.8
20.9
1410
185
2.0
23.3
1760
240
2.2
26.6
2310
300
2.4
29.6
2880
400
2.6
33.2
3680
500
2.8
36.9
4700
630
2.8
41.1
6010
Nominal area of
conductor
Nominal Insulation
Thickness
Maximum overall
diameter
Approximate
weight
(mm)
1.5
(mm)
0.7
(mm)
3.4
(kg/km)
20
2.5
0.8
4.1
32
Insulation: PVC
0.8
4.8
46
0.8
5.3
65
10
1.0
6.8
110
16
1.0
8.1
165
Note :
25
1.2
10.2
255
35
1.2
11.7
345
50
1.4
13.9
495
70
1.4
16.0
670
Voltage: 450/750 V
Code: HO7V-K
Conductor: Flexible Copper Class 5
95
1.6
18.2
920
120
1.6
20.2
1130
150
1.8
22.5
1400
185
2.0
24.9
1730
240
2.2
28.4
2250
Average
Insulation
Thickness
Maximum
O/D
Approx.
Cable
Weight
Standard : BS 6500.
(mm2)
(mm)
(mm)
(Kg/Km)
Insulation : PVC.
0.6
7.2
59
1.0
0.6
7.5
67
1.5
0.7
8.6
85
2.5
0.8
10.6
130
0.75
0.6
7.6
69
1.0
0.6
8.0
80
1.5
0.7
9.4
105
2.5
0.8
11.4
155
0.6
8.3
78
1.0
0.6
9.0
101
1.5
0.7
10.5
141
2.5
0.8
12.5
214
300/500 VOLT PVC INSULATED AND SHEATHED TWIN CORE FLAT CABLE
Nominal
Conductor
Area
Average
Insulation
Thickness
Average
Sheath
Thickness
Maximum
O/D
Approx.
Cable
Weight
Standard : BS 6004.
(mm2)
(mm)
(mm)
(mm)
(Kg/Km)
Insulation : PVC.
2 x 1.5
0.7
0.9
5.4 x 8.4
68
2 x 2.5
0.8
6.2 x 9.8
100
2 x 4.0
0.8
7.2 x 11.5
145
2 x 6.0
0.8
1.1
8.0 x 13.0
198
0.7
0.9
5.4 x 9.6
76.8
2 x 2.5 + 1.5
0.8
6.2 x 11.5
113
2 x 4.0 + 1.5
0.8
7.2 x 13.0
158
2 x 6.0 + 2.5
0.8
1.1
8.0 x 15.0
220
10
0.6/1 KV(1.2), SINGLE & MULTI CORE xLPE INSULATED LEAD SHEATHED
ARMOURED COPPER CONDUCTOR CABLES
Nominal
area of
conductor
S
I
N
G
L
E
C
O
R
E
T
W
O
C
O
R
E
T
h
R
E
E
C
O
R
E
mm
50
70
95
120
150
185
240
300
400
500
630
800
1000
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
Nominal
Nominal
Nominal
Insulation Thickness of Diameter of
Thickness Lead Sheath Armour
mm
1.0
1.1
1.1
1.2
1.4
1.6
1.7
1.8
2.0
2.2
2.4
2.6
2.8
0.7
0.7
0.7
0.7
0.7
0.7
0.9
0.9
1.0
1.1
1.1
1.2
1.4
1.6
1.7
1.8
2.0
0.7
0.7
0.7
0.7
0.7
0.7
0.9
0.9
1.0
1.1
1.1
1.2
1.4
1.6
1.7
1.8
2.0
mm
1.2
1.2
1.2
1.3
1.3
1.4
1.5
1.5
1.6
1.7
1.8
1.9
2.1
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.3
1.4
1.5
1.6
1.7
1.9
2.0
2.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.3
1.4
1.5
1.6
1.7
1.8
2.0
2.1
2.4
mm
1.6
1.6
1.6
1.6
1.6
1.6
2.0
2.0
2.0
2.5
2.5
2.5
2.5
1.25
1.25
1.25
1.25
1.6
1.6
1.6
1.6
2.0
2.0
2.0
2.5
2.5
2.5
2.5
2.5
3.15
1.25
1.25
1.25
1.25
1.6
1.6
1.6
1.6
2.0
2.0
2.0
2.5
2.5
2.5
2.5
2.5
3.15
Approx.
Overall
Diameter
Approx.
weight
mm
23.5
25.5
27.0
29.0
31.0
33.5
37.5
40.0
44.5
49.5
54.5
59.5
65.0
18.5
19.0
20.5
21.5
24.0
25.5
26.5
28.0
31.5
35.0
38.5
42.0
45.5
49.5
55.5
60.0
67.5
19.0
19.5
21.0
22.5
25.0
26.5
28.5
30.5
34.5
38.5
42.5
46.0
50.5
55.0
61.5
66.5
75.5
kg/km
1520
1840
2170
2600
3000
3620
4560
5320
6640
8270
10220
12550
15380
940
1040
1170
1330
1670
1910
2120
2440
3120
3910
4830
5940
7010
8320
10440
12370
15880
1000
1100
1260
1430
1830
2150
2520
2970
3900
4980
6210
7660
9040
10820
13630
16230
21080
0.6/1 KV(1.2), SINGLE & MULTI CORE xLPE INSULATED LEAD SHEATHED
ARMOURED COPPER CONDUCTOR CABLES
F
O
U
R
C
O
R
E
Nominal
Nominal
Nominal
Nominal
area
Insulation Thickness of Diameter of
of conductor Thickness Lead Sheath Armour
mm
mm
mm
mm
1.5
0.7
1.2
1.25
2.5
0.7
1.2
1.25
4
0.7
1.2
1.25
6
0.7
1.2
1.6
10
0.7
1.2
1.6
16
0.7
1.2
1.6
25
0.9
1.2
1.6
35
0.9
1.2
2.0
50
1.0
1.3
2.0
70
1.1
1.5
2.0
95
1.1
1.6
2.5
120
1.2
1.7
2.5
150
1.4
1.8
2.5
185
1.6
2.0
2.5
240
1.7
2.2
2.5
300
1.8
2.3
3.15
400
2.0
2.6
3.15
Cable Size
Core No x
mm
5x1.5
7x1.5
10x1.5
12x1.5
19x1.5
24x1.5
27x1.5
30x1.5
37x1.5
48x1.5
5x2.5
7x2.5
10x2.5
12x2.5
19x2.5
24x2.5
27x2.5
30x2.5
37x2.5
48x2.5
5x4
7x4
10x4
12x4
19x4
24x4
27x4
30x4
37x4
48x4
Approx.
Overall
Diameter
mm
19.5
20.5
22.0
24.0
26.5
28.5
31.0
34.5
38.5
43.0
49.0
52.0
57.5
63.0
69.5
77.0
85.5
Nominal
Nominal
Nominal
Approx.
Insulation Thickness of Diameter of
Overall
Thickness Lead Sheath
Armour
Diameter
mm
mm
mm
mm
Nominal area of Condutor 1.5 mm2
0.7
1.2
1.25
20.5
0.7
1.2
1.25
21.5
0.7
1.2
1.6
25.0
0.7
1.2
1.6
25.5
0.7
1.2
1.6
28.0
0.7
1.2
1.6
31.0
0.7
1.2
1.6
31.5
0.7
1.3
1.6
32.5
0.7
1.3
2.0
35.5
0.7
1.4
2.0
39.5
Nominal area of Condutor 2.5 mm2
0.7
1.2
1.25
21.5
0.7
1.2
1.25
22.5
0.7
1.2
1.6
26.5
0.7
1.2
1.6
27.0
0.7
1.2
1.6
30.5
0.7
1.3
1.6
34.5
0.7
1.3
2.0
35.5
0.7
1.3
2.0
36.5
0.7
1.4
2.0
39.0
0.7
1.5
2.0
43.5
Nominal area of Condutor 4 mm2
0.7
1.2
1.6
24.0
0.7
1.2
1.6
25.0
0.7
1.2
1.6
29.0
0.7
1.2
1.6
29.5
0.7
1.3
1.6
33.5
0.7
1.4
2.0
39.0
0.7
1.4
2.0
39.5
0.7
1.4
2.0
41.0
0.7
1.5
2.0
44.0
0.7
1.6
2.5
50.5
Approx.
weight
kg/km
1080
1210
1390
1730
2070
2460
2970
3810
4730
6200
8150
9580
11590
14010
17430
21660
26840
Approx.
weight
kg/km
1170
1270
1710
1790
2150
2530
2630
2830
3400
4070
1320
1450
1960
2060
2530
3110
3470
3660
4160
5060
1650
1830
2330
2470
3180
4180
4380
4620
5350
6950
11
12
Nominal
Insulation
thickness
(mm2)
(mm)
Nominal
Lead sheath
thickness
Nominal dia
of Gal. Steel
Round Wire
Approx.
Overall Dia
Approx.
Weight
(mm)
(mm)
(mm)
(kg/km)
95
2.5
2.0
2.5
63.0
10480
120
2.5
2.1
2.5
67.0
11990
150
2.5
2.1
2.5
71.0
13370
185
2.5
2.2
2.5
75.0
15430
240
2.6
2.4
3.15
83.0
19370
300
2.8
2.6
3.15
90.0
22900
400
3.0
2.8
3.15
99.0
27810
Chemical and/or
Environmental protection:
Lead Alloy E Sheath
95
3.4
2.1
2.5
68.0
11560
120
3.4
2.2
2.5
72.0
13250
150
3.4
2.3
3.15
77.0
15520
185
3.4
2.4
3.15
82.0
17750
240
3.4
2.5
3.15
87.0
20660
300
3.4
2.6
3.15
93.0
23740
400
3.4
2.8
3.15
101.0
28330
Insulation : xLPE.
4.5
2.2
2.5
74.0
13040
120
4.5
2.3
3.15
79.0
15470
150
4.5
2.4
3.15
83.0
17110
185
4.5
2.5
3.15
87.0
19370
240
4.5
2.6
3.15
93.0
22450
300
4.5
2.8
3.15
99.0
25850
400
4.5
3.0
3.15
107.0
30550
5.5
2.4
3.15
81.0
15470
120
5.5
2.4
3.15
85.0
16990
150
5.5
2.5
3.15
88.0
18620
185
5.5
2.6
3.15
93.0
21060
240
5.5
2.8
3.15
99.0
24460
300
5.5
2.9
3.15
104.0
27590
400
5.5
3.1
3.15
112.0
32400
94.0
19460
8.0
2.7
3.15
120
8.0
2.8
3.15
98.0
21340
150
8.0
2.9
3.15
101.0
23210
185
8.0
3.0
3.15
106.0
25620
240
8.0
3.1
3.15
112.0
28930
300
8.0
3.2
3.15
117.0
32380
400
8.0
3.4
3.15
125.0
37550
13
Nominal
Insulation
thickness
(mm)
95
120
150
185
240
300
400
500
630
800
1000
2.5
2.5
2.5
2.5
2.6
2.8
3.0
3.2
3.2
3.2
3.2
95
120
150
185
240
300
400
500
630
800
1000
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
95
120
150
185
240
300
400
500
630
800
1000
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
95
120
150
185
240
300
400
500
630
800
1000
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
95
120
150
185
240
300
400
500
630
800
1000
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
Nominal
Nominal dia
Approx.
Lead sheath of Aluminium Overall Dia
thickness
Round Wire
(mm)
(mm)
(mm)
Uo/U (Um) = 3.6/6 (7.2)
1.4
1.6
1.4
2.0
1.5
2.0
1.5
2.0
1.6
2.0
1.7
2.0
1.8
2.5
1.9
2.5
2.0
2.5
2.1
2.5
2.2
2.5
Uo/U (Um) = 6/10 (12)
1.4
2.0
1.5
2.0
1.5
2.0
1.6
2.0
1.6
2.0
1.7
2.5
1.8
2.5
1.9
2.5
2.0
2.5
2.1
2.5
2.2
2.5
Uo/U (Um) = 8.7/15 (17.5)
1.5
2.0
1.6
2.0
1.6
2.0
1.6
2.0
1.7
2.5
1.8
2.5
1.9
2.5
1.9
2.5
2.0
2.5
2.2
2.5
2.3
2.5
Uo/U (Um) = 12/20 (24)
1.6
2.0
1.6
2.0
1.7
2.0
1.7
2.5
1.8
2.5
1.8
2.5
1.9
2.5
2.0
2.5
2.1
2.5
2.2
2.5
2.3
2.5
Uo/U (Um) = 18/30 (36)
1.7
2.5
1.8
2.5
1.8
2.5
1.9
2.5
1.9
2.5
2.0
2.5
2.1
2.5
2.2
2.5
2.3
2.5
2.4
3.15
2.5
3.15
Approx.
Weight
(kg/km)
34.0
37.0
38.0
40.0
44.0
47.0
52.0
56.0
61.0
65.0
71.0
2960
3420
3890
4430
5390
6350
7830
9420
11530
13800
16550
37.0
38.0
40.0
43.0
45.0
49.0
53.0
56.0
61.0
65.0
71.0
3240
3720
4110
4830
5590
6650
7960
9480
11570
13850
16610
39.0
41.0
43.0
45.0
49.0
51.0
55.0
59.0
64.0
68.0
74.0
3640
4150
4630
5160
6220
7160
8510
9940
12020
14540
17340
42.0
44.0
46.0
49.0
52.0
54.0
58.0
62.0
66.0
71.0
76.0
4040
4520
5030
5760
6700
7530
8950
10540
12640
15080
17780
49.0
51.0
53.0
55.0
58.0
60.0
64.0
68.0
73.0
78.0
83.0
5140
5690
6140
6900
7810
8840
10270
11930
14230
16940
19800
Insulation : xLPE
Insulation Screen : Extruded
Layer of Semi-conducting Material
Metallic Screen : Copper Tape
Inner sheath : Extruded PVC
Chemical and/or Environmental
protection : Lead Alloy E Sheath
Bedding for Armour :
Extruded PVC
Armouring: Single layer of
Aluminium Wire
Sheathing: Extruded PVC
Operating Temperature : 90C
for continuous operation 250C
for short circuit conditions
Outer Sheath : Extruded PVC
Note :
1) Above data is approximate and
subject to manufacture tolerance.
2) Cables can be offered with FR/
FRLS/LSZH properties.
14
1P
2P
5P
10P
20P
1P
2P
5P
10P
20P
1P
2P
5P
10P
20P
1P
2P
5P
10P
20P
Nominal
area of
conductor
Minimum
Insulation
Thickness
Nominal
Thickness
of Lead
Sheath
Nominal
steel
armour Wire
Diameter
Approx.
Overall
Diameter
Approx.
weight
(mm)
(mm)
(mm)
(mm)
(mm)
(kg/km)
0.5
0.5
0.5
0.5
0.5
0.75
0.75
0.75
0.75
0.75
1.0
1.0
1.0
1.0
1.0
1.5
1.5
1.5
1.5
1.5
0.44
0.44
0.44
0.44
0.44
0.44
0.44
0.44
0.44
0.44
0.44
0.44
0.44
0.44
0.44
0.44
0.44
0.44
0.44
0.44
0.9
0.9
1.0
1.1
1.2
0.9
1.0
1.0
1.2
1.3
0.9
1.0
1.0
1.2
1.3
0.9
1.0
1.1
1.2
1.4
0.9
0.9
0.9
1.25
1.25
0.9
0.9
1.25
1.25
1.25
0.9
0.9
1.25
1.25
1.6
0.9
0.9
1.25
1.25
1.6
15.0
18.0
20.5
27.0
32.5
15.0
19.0
22.5
28.0
34.0
15.5
19.5
23.5
29.5
36.5
16.5
20.5
25.0
32.0
40.0
570
770
1040
1710
2360
600
880
1270
1920
2720
630
930
1350
2080
3170
680
1020
1570
2380
3820
Standard: EN 50288-7
Voltage: 500 V
Conductor: Bare Copper
Conductor (Class 2 or Class 5)
Insulation: xLPE
Pair identification: Pairs will be
numbered, each pair having
1 White & 1 Blue Core
Collective screen: Aluminium
Mylar tape with Tinned Copper
drain Wire
Inner sheath: Extruded PVC
Chemical and/or Environmental
protection: Lead Alloy E Sheath
Bedding for Armour:
Extruded PVC
Armouring: Single layer of
Galvanized Steel Wire
Outer Sheathing: Extruded PVC
Note :
These cables can also be offered with
Fire Resitant properties with LSOH
sheath.
2P
5P
10P
20P
2P
5P
10P
20P
2P
5P
10P
20P
2P
5P
10P
20P
Nominal
area of
conductor
Minimum
Insulation
Thickness
Nominal
Nominal
Thickness of
steel
Lead Sheath armour Wire
Diameter
(mm)
(mm)
(mm)
0.5
0.5
0.5
0.5
0.75
0.75
0.75
0.75
1.0
1.0
1.0
1.0
1.5
1.5
1.5
1.5
0.44
0.44
0.44
0.44
0.44
0.44
0.44
0.44
0.44
0.44
0.44
0.44
0.44
0.44
0.44
0.44
1.0
1.1
1.2
1.3
1.0
1.1
1.2
1.4
1.0
1.1
1.3
1.4
1.0
1.1
1.3
1.5
Approx.
Overall
Diameter
Approx.
weight
(mm)
(mm)
(kg/km)
0.9
1.25
1.25
1.6
0.9
1.25
1.25
1.6
0.9
1.25
1.25
1.6
1.25
1.25
1.6
1.6
19.5
23.5
30.0
36.5
20.0
24.5
31.0
39.0
21.0
25.5
32.5
41.0
23.0
27.0
35.5
44.5
930
1400
2090
3120
970
1480
2230
3580
1040
1600
2500
3900
1270
1790
3020
4570
Standard: EN 50288-7
Voltage: 500 V
Conductor: Bare Copper
Conductor (Class 2 or Class 5)
Insulation: xLPE
Pair identification: Pairs will
be numbered, each pair having 1
White & 1 Blue Core.
Individual screen: Aluminium
Mylar tape with Tinned Copper
drain Wire
Collective screen: Aluminium
Mylar tape with Tinned Copper
drain Wire
Chemical and /or environmental
protection: Lead Alloy E Sheath
Bedding: Extruded PVC
Armouring: Single layer of
Galvanised Steel Wire
Sheathing: Extruded PVC
Temperature rating: 90C Max.
Conductor Operating temperature
Note :
These cables can also be offered with
Fire Resitant properties with LSOH
sheath
15
Nominal
Insulation
Thickness
(mm)
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.9
0.9
1.0
1.1
1.1
1.2
1.4
1.6
1.7
1.8
2.0
0.7
0.7
0.7
0.7
0.9
0.9
1.0
1.1
1.1
1.2
1.4
1.6
1.7
1.8
2.0
Nominal steel
armour Wire
Diameter
(mm)
0.9
0.9
0.9
1.25
0.9
0.9
1.25
1.25
1.6
1.6
1.6
1.6
2.0
2.0
2.5
2.5
2.5
2.5
2.5
0.9
1.25
1.25
1.25
1.6
1.6
1.6
2.0
2.0
2.5
2.5
2.5
2.5
2.5
3.15
Approximate
Overall
Diameter
(mm)
14.5
15.5
17.5
20.0
15.0
16.5
19.0
21.0
24.0
26.0
29.0
32.5
37.5
39.5
44.5
48.5
53.5
58.5
65.0
16.0
18.5
20.5
23.0
26.5
29.0
32.5
38.0
42.0
46.0
50.5
55.5
61.5
67.0
76.0
Approximate
weight
Nominal
Insulation
Thickness
(mm)
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
Nominal steel
armour Wire
Diameter
(mm)
0.9
0.9
0.9
0.9
0.9
1.25
1.25
1.25
1.6
1.6
1.6
0.9
0.9
0.9
0.9
0.9
1.25
1.25
1.6
1.6
1.6
2.0
Approximate
Overall
Diameter
(mm)
12.0
12.5
13.0
14.0
15.0
18.5
19.0
22.0
26.5
29.0
32.5
13.5
14.0
15.0
16.0
17.0
21.5
22.0
26.5
30.5
33.5
39.0
Approximate
weight
(kg/km)
400
480
630
860
450
560
830
1040
1480
1830
2300
3020
4180
4960
6320
7600
9520
11550
14290
520
750
980
1250
1820
2280
2880
4140
5300
6750
8040
9760
12290
14930
19370
(kg/km)
265
295
330
365
415
640
690
900
1340
1610
1950
335
375
425
460
540
830
910
1380
1770
2170
2950
Standard: BS 5467
Voltage: 600/1000 V
Code: 2xWY
Conductor: Stranded Copper Class 2
Insulation: xLPE
Bedding: Extruded PVC
Armouring: Single layer of
Galvanised Steel Wire
Sheathing: Extruded PVC
Operating Temperature: 90C
Short Circuit Temperature: 250C
Note :
1) Above data is approximate and
subject to manufacture tolerance.
2) Cables can be offered with FR &
LSF properties.
3) Cables can be offered with IEC
60502-1 specification.
Standard: BS 5467
Voltage: 600/1000 V
Code: 2xWY
Conductor: Stranded Copper Class 2
Insulation: xLPE
Bedding: Extruded PVC
Armouring: Single layer of
Galvanised Steel Wire
Sheathing: PVC
Operating Temperature: 90C
Short Circuit Temperature: 250C
Note :
1) Above data is approximate and
subject to manufacture tolerance.
2) Cables can be offered with FR &
LSF properties.
3) Cables can be offered with IEC
60502-1 specification.
16
Nominal
Insulation
Thickness
Nominal Steel
Wire Diameter
Approx.
O/D.
Approx.
Cable
Weight
(mm2)
(mm)
(mm)
(mm)
(Kg/Km)
70
2.5
2.5
50.6
5400
Insulation : xLPE
95
2.5
2.5
54.5
6300
120
2.5
2.5
58.1
7200
150
2.5
2.5
61.1
8300
185
2.5
2.5
65.2
9600
240
2.6
2.5
70.7
11800
300
2.8
3.15
78.5
15000
400
3.0
3.15
85.5
18300
3.4
2.5
59.2
6900
120
3.4
2.5
62.6
8000
Note :
150
3.4
2.5
65.6
8900
185
3.4
2.5
69.7
10300
240
3.4
3.15
75.0
13900
300
3.4
3.15
81.5
15500
4.5
2.5
64.5
7600
120
4.5
2.5
68.2
8700
150
4.5
2.5
71.2
9600
185
4.5
3.15
75.2
11300
240
4.5
3.15
81.7
14100
300
4.5
3.15
86.8
16500
400
4.5
3.15
93.3
19500
95
5.5
2.5
72.1
8930
120
5.5
2.5
75.8
10030
150
5.5
3.15
80.7
12400
185
5.5
3.15
84.5
13880
240
5.5
3.15
90.4
16200
300
5.5
3.15
95.2
18600
400
5.5
3.15
102.1
21560
8.0
3.15
85.8
11770
120
8.0
3.15
89.1
12950
150
8.0
3.15
92.7
14480
185
8.0
3.15
96.5
16010
240
8.0
3.15
102.4
18500
300
8.0
3.15
107.2
20950
17
Nominal
Insulation
Thickness
(mm)
(mm)
70
95
120
150
185
240
300
400
500
630
800
1000
2.5
2.5
2.5
2.5
2.5
2.6
2.8
3.0
3.2
3.2
3.2
3.2
95
120
150
185
240
300
400
500
630
800
1000
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
95
120
150
185
240
300
400
500
630
800
1000
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
95
120
150
185
240
300
400
500
630
800
1000
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
95
120
150
185
240
300
400
500
630
800
1000
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
Nominal
Aluminium armour
Wire Diameter
Approximate
Overall
Diameter
(mm)
CORE : 3.6/6 (7.2) kv.
1.6
1.6
1.6
1.6
2.0
2.0
2.0
2.0
2.5
2.5
2.5
2.5
CORE : 6/10 (12) kv.
1.6
1.6
2.0
2.0
2.0
2.0
2.0
2.5
2.5
2.5
2.5
CORE : 8.7/15 (17.5) kv.
2.0
2.0
2.0
2.0
2.0
2.0
2.5
2.5
2.5
2.5
2.5
CORE : 12/20 (24) kv.
2.0
2.0
2.0
2.0
2.0
2.5
2.5
2.5
2.5
2.5
2.5
CORE : 18/30 (36) kv.
2.0
2.0
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
Approximate
weight
(mm)
(kg/km)
25.0
27.0
29.0
30.0
33.0
35.0
38.0
42.0
47.0
51.0
55.0
60.0
1200
1490
1750
2050
2510
3120
3770
4680
5970
7470
9220
11310
29.0
31.0
33.0
35.0
37.0
39.0
43.0
47.0
52.0
56.0
60.0
1580
1860
2240
2640
3240
3860
4750
6000
7510
9270
11350
32.0
34.0
35.0
37.0
40.0
42.0
47.0
50.0
54.0
58.0
63.0
1790
2080
2370
2800
3410
4020
5090
6210
7730
9530
11630
34.0
36.0
37.0
39.0
42.0
45.0
49.0
52.0
56.0
61.0
65.0
1920
2200
2520
2940
3550
4340
5260
6420
7950
9760
11860
40.0
41.0
44.0
46.0
48.0
51.0
54.0
57.0
62.0
66.0
70.0
2290
2580
3060
3510
4140
4820
5780
6960
8500
10390
12510
18
1P
2P
5P
10P
20P
1P
2P
5P
10P
20P
1P
2P
5P
10P
20P
1P
2P
5P
10P
20P
Nominal area
of conductor
Minimum
Insulation
Thickness
Nominal steel
armour
Wire Dia.
Approx.
Overall
Diameter
Approx.
weight
(mm)
(mm)
(mm)
(mm)
(kg/km)
0.5
0.5
0.5
0.5
0.5
0.75
0.75
0.75
0.75
0.75
1.0
1.0
1.0
1.0
1.0
1.5
1.5
1.5
1.5
1.5
0.44
0.44
0.44
0.44
0.44
0.44
0.44
0.44
0.44
0.44
0.44
0.44
0.44
0.44
0.44
0.44
0.44
0.44
0.44
0.44
0.9
0.9
0.9
0.9
1.25
0.9
0.9
0.9
1.25
1.25
0.9
0.9
0.9
1.25
1.25
0.9
0.9
0.9
1.25
1.25
11.0
14.0
16.5
21.5
27.5
11.0
14.5
17.5
23.5
29.0
11.5
15.0
18.5
25.0
31.0
12.0
16.0
20.0
27.0
34.0
215
310
440
690
1190
225
345
510
910
1360
240
375
560
1010
1560
270
420
650
1210
1890
Standard: EN 50288-7
Voltage: 500 V
Conductor: Bare Copper
Conductor (Class 2 or Class 5)
Insulation: PE / PVC
Pair identification: Pairs will
be numbered, each pair having 1
White & 1 Blue Core.
Collective screen: Aluminium
Mylar tape with Tinned Copper
drain Wire
Inner Sheath: Extruded PE/PVC
Armouring: Single layer of
Galvanised Steel Wire
Sheathing: PVC
Temperature rating: 70C Max
Conductor Operating
temperature
Note :
These cables can also be offered with
Fire Survival/Resistant properties
with LSOH sheath
1T
2T
5T
10T
20T
1T
2T
5T
10T
20T
1T
2T
5T
10T
20T
1T
2T
5T
10T
20T
Nominal
area of
conductor
Minimum
Insulation
Thickness
Nominal
steel armour
Wire
Diameter
Approx.
Overall
Diameter
Approx.
Standard: EN 50288-7
weight
Voltage: 500 V
(mm)
(mm)
(mm)
(mm)
0.5
0.5
0.5
0.5
0.5
0.75
0.75
0.75
0.75
0.75
1.0
1.0
1.0
1.0
1.0
1.5
1.5
1.5
1.5
1.5
0.44
0.44
0.44
0.44
0.44
0.44
0.44
0.44
0.44
0.44
0.44
0.44
0.44
0.44
0.44
0.44
0.44
0.44
0.44
0.44
0.9
0.9
0.9
1.25
1.25
0.9
0.9
0.9
1.25
1.25
0.9
0.9
0.9
1.25
1.25
0.9
0.9
0.9
1.25
1.6
11.5
15.0
18.0
24.5
30.5
11.5
15.5
19.0
26.0
32.5
12.0
16.5
20.0
27.5
34.5
13.0
18.0
22.0
30.0
38.5
(kg/km)
230
365
540
980
1480
250
395
610
1130
1740
265
430
670
1270
1970
305
510
820
1520
2660
Nominal
area of
conductor
Minimum
Insulation
Thickness
Nominal
steel armour
Wire Diameter
Approx
Overall
Diameter
Approx.
weight
(mm)
(mm)
(mm)
(mm)
(kg/km)
Standard: EN 50288-7
Voltage: 500 V
Conductor: Bare Copper
Conductor (Class 2 or Class 5)
2P
0.5
0.44
0.9
15.0
365
Insulation: PE / PVC
5P
0.5
0.44
0.9
18.5
540
10P
0.5
0.44
1.25
25.0
990
20P
0.5
0.44
1.25
31.0
1480
2P
0.75
0.44
0.9
15.5
395
5P
0.75
0.44
0.9
19.0
590
10P
0.75
0.44
1.25
26.5
1100
20P
0.75
0.44
1.25
32.5
1680
2P
1.0
0.44
0.9
16.5
425
5P
1.0
0.44
0.9
20.0
650
10P
1.0
0.44
1.25
27.5
1210
Sheathing: PVC
20P
1.0
0.44
1.25
35.0
1900
2P
1.5
0.44
0.9
18.0
490
5P
1.5
0.44
0.9
22.0
760
Note :
10P
1.5
0.44
1.25
30.0
1430
20P
1.5
0.44
1.6
39.0
2480
Nominal
area of
conductor
Minimum
Insulation
Thickness
Nominal
steel armour
Wire
Diameter
Approx.
Overall
Diameter
Approx.
weight
(kg/km)
(mm)
(mm)
(mm)
(mm)
2T
0.5
0.44
0.9
16.5
415
5T
0.5
0.44
0.9
20.0
630
10T
0.5
0.44
1.25
27.5
1170
20T
0.5
0.44
1.25
34.0
1800
2T
0.75
0.44
0.9
17.5
470
5T
0.75
0.44
0.9
21.0
720
10T
0.75
0.44
1.25
29.0
1330
20T
0.75
0.44
1.6
37.0
2280
2T
1.0
0.44
0.9
18.0
510
5T
1.0
0.44
0.9
22.0
790
10T
1.0
0.44
1.25
30.5
1480
20T
1.0
0.44
1.6
39.5
2580
Standard: EN 50288-7
Voltage: 500 V
Conductor: Bare Copper
Conductor (Class 2 or Class 5)
Insulation: PE / PVC
Pair identification: Pairs will
be numbered, each pair having 1
White & 1 Blue Core.
Individual screen: Aluminium
Mylar tape with Tinned Copper
drain Wire
Collective screen: Aluminium
Mylar tape with Tinned Copper
drain Wire
Inner Sheath: Extruded PE/PVC
Armouring: Single layer of
Galvanised Steel Wire
Sheathing: PVC
Temperature rating: 70C
Max. Conductor Operating
temperature
2T
1.5
0.44
0.9
19.5
570
5T
1.5
0.44
1.25
25.0
1060
Note :
10T
1.5
0.44
1.25
33.5
1750
20T
1.5
0.44
1.6
43.0
3110
19
ehV cableS
20
Metallic Sheath
Metallic Sheath is must for cables above 33 kV as
the cable of voltage grade 66 kV & above are working
with dielectric stress of above 6 kV / mm & at this
level of dielectric stress presence of water triggers
tree formation in the insulation resulting in cable
failure.
Water can enter the cable longitudinally as well as
radially. Longitudinal water entry can be blocked by
using water swellable tape on the core. Lead sheath
can block the entry in radial direction.
Lead sheath is extruded by continuous lead
extruder which is equipped with micro-processor
based temperature controllers & drives to achieve
uniform thickness, better concentricity. Lead sheath
in addition to other electrical & manufacturing
advantages has a life span of minimum 40 to 45
years.
System voltage
Impulse level
PRODUCT RANGE
BRAIDED CABLES
THERMOCOUPLE / COMPENSATING CABLES
SOLAR AC / DC CABLES
TELEPHONE CABLES
PANEL BOARD WIRES
CO-AXIAL CABLES
LAN CABLES
SUBMERSIBLE CABLES
RAILWAY SIGNALLING CABLES
M.V. / L.V. AERIAL BUNCHED CABLES
SPECIALITY CABLES
Suited for Marine / Oil & Gas / Extreme Fire conditions /
Highly corrosive environment / Traffic / Aircraft /
Space Station / Automobiles.
Australia
Canada
Congo
Cyprus
Egypt
Europe
Ghana
Iran
Iraq
Jordan
Kenya
Kuwait
Libya
Malaysia
Mauritius
New Zealand
Nigeria
Oman
Qatar
Rwanda
Saudi Arabia
South Africa
South Korea
Sri Lanka
Sudan
Syria
Tanzania
U.A.E.
U.K.
Uganda
Zambia
E-mail : exports@polycab.com
Website : www.polycab.com