You are on page 1of 27

MEP Milestone Date

Days Remain: -235

(from 31 March 16)

Date :

Floor Area
Floor

B1

Structural
Completion
Date
(Revised
Schedule)

Done

Target Structural / Actual Structural /


Architectural
Architectural
Clearance Issue Clearance Issued
Date
Date

Done

Done

1st & 2nd Fix


Target
Start Date

Started

Actual
Start Date

Started

Target
Completion
Date

30-Nov-15

Final Fix
Actual
Completion (%)

89%

Target
Completion
Date

3-Dec-15

Major Plant Room


Actual
Completion (%)

26%

L1

Done

22-Jul-15

22-Jul-15

Started

Started

31-Dec-15

83%

6-Dec-15

11%

L2

1-Jun-15

27-Jul-15

27-Jul-15

3-Aug-15

7-Aug-15

31-Dec-15

77%

9-Dec-15

11%

L3

12-Jun-15

15-Aug-15

11-Aug-15

17-Aug-15

17-Aug-15

15-Dec-15

78%

12-Dec-15

9%

L4

23-Jun-15

19-Aug-15

18-Aug-15

21-Aug-15

24-Aug-15

15-Dec-15

82%

15-Dec-15

8%

L5

4-Jul-15

23-Aug-15

22-Aug-15

25-Aug-15

26-Aug-15

15-Dec-15

82%

18-Dec-15

10%

L6

15-Jul-15

27-Aug-15

25-Aug-15

29-Aug-15

3-Sep-15

15-Dec-15

82%

21-Dec-15

9%

L7

26-Jul-15

31-Aug-15

8-Sep-15

2-Sep-15

21-Sep-15

20-Dec-15

73%

24-Dec-15

8%

L8

29-Aug-15

18-Sep-15

16-Sep-15

20-Sep-15

20-Oct-15

20-Dec-15

61%

27-Dec-15

5%

L9

4-Sep-15

24-Sep-15

12-Oct-15

26-Sep-15

20-Oct-15

20-Dec-15

75%

30-Dec-15

8%

L10

10-Sep-15

2-Oct-15

21-Oct-15

4-Oct-15

9-Nov-15

31-Dec-15

83%

2-Jan-16

9%

L11

18-Sep-15

12-Oct-15

31-Oct-15

14-Oct-15

9-Jan-16

31-Dec-15

82%

5-Jan-16

9%

L12

28-Sep-15

20-Oct-15

20-Nov-15

22-Oct-15

10-Jan-16

15-Jan-15

81%

8-Jan-16

9%

L13

6-Oct-15

28-Oct-15

3-Dec-15

30-Oct-15

10-Jan-16

15-Jan-15

81%

11-Jan-16

9%

L14

14-Oct-15

6-Nov-15

4-Dec-15

8-Nov-15

17-Jan-16

15-Jan-15

78%

14-Jan-16

9%

L15

23-Oct-15

15-Nov-15

11-Dec-15

17-Nov-15

29-Jan-16

15-Jan-15

76%

17-Jan-16

8%

L16

1-Nov-15

26-Nov-15

28-Dec-15

28-Nov-15

29-Jan-16

30-Jan-15

77%

20-Jan-16

9%

L17

12-Nov-15

4-Dec-15

6-Dec-15

30-Jan-16

30-Jan-15

70%

23-Jan-16

6%

L18

20-Nov-15

12-Dec-15

14-Dec-15

7-Feb-16

30-Jan-15

58%

26-Jan-16

7%

L19

28-Nov-15

20-Dec-15

22-Dec-15

12-Feb-16

30-Jan-15

52%

29-Jan-16

7%

L20

6-Dec-15

28-Dec-15

13-Jan-16

30-Dec-15

13-Feb-16

30-Jan-15

45%

1-Feb-16

4%

L21

14-Dec-15

5-Jan-16

18-Jan-16

7-Jan-16

12-Feb-16

6-Feb-16

21%

11-Feb-16

0%

L22

22-Dec-15

13-Jan-16

15-Jan-16

18-Feb-16

14-Feb-16

19%

19-Feb-16

0%

L23

30-Dec-15

29-Jan-16

31-Jan-16

20-Feb-16

1-Mar-16

13%

6-Mar-16

0%

Lower Roof
(Core area
Y4 to Y10)

23-Dec-15

6-Jan-16

13-Jan-16

8-Jan-16

Lower Roof
(Y1a to Y4)

8-Jan-15

15-Jan-15

17-Jan-15

Upper Roof

15-Jan-16

23-Jan-16

25-Jan-16

10-Feb-16

10-Feb-16

22-Feb-16

16-Feb-15

24-Feb-16

0%

0%

27-Feb-16

16-Feb-15

29-Feb-16

0%

0%

Proposed
Equipment
Delivery Date

Target Structural /
Architectural
Actual Structural /
Estimated
Clearance Issue
Architectural
Delivery Date
Date
Clearance Issue
(MCI & IL
Date
Approved)

15-Mar-16

Target
Completion
Date

Actual Completion
(%)

31-Jan-15
31-Dec-15
31-Dec-15
30-Nov-15
31-Dec-15
31-Dec-15
31-Dec-15
31-Dec-15
15-Jan-15
31-Dec-15

90%
0%
20%
90%
95%
60%
0%
0%
30%
30%

31-Dec-15

0%

18-Oct-15
12-Oct-15
5-Oct-15

15-Dec-15
4-Feb-15
31-Dec-15

95%
90%
70%

25-Sep-15
17-Oct-15

31-Dec-15
31-Dec-15

80%
60%

Actual
Delivery Date

Fuel Tank Chamber


Domestic Water Pump Rm
Ejector Pit
Sewage Treatment Room
HT Switch Room
Fire Pump Room
Diesel Pump Room
Gas Cylinder Room
MDF Room
Sprinkler Pump Room

(A)
1-Dec-14
31-Oct-15
21-Nov-15
6-Aug-15
30-Oct-15
30-Oct-15
1-Oct-15
1-Oct-15
10-Oct-15
27-Sep-15

Done
20-Nov-15
20-Nov-15
Done
23-Oct-15
23-Oct-15
24-Sep-15
24-Sep-15
3-Oct-15
20-Sep-15

IT Room

31-Oct-15

24-Oct-15

Transformer Room
LV Switch Room
PAHU Room

17-Oct-15
12-Oct-15
5-Oct-15

10-Oct-15
15-Jan-15
26-Oct-15

Done
11-Jan-16
Done

Chiller Room
Generator Room

20-Sep-15
17-Oct-15

13-Sep-15
10-Oct-15

20-Sep-15
Done

Cooling Tower Room

27-Oct-15

27-Oct-15

Done

28-Oct-15

20-Dec-15

85%

Lift Machine Room

1-Dec-15

4-Dec-15

Done

4-Jan-16

15-Jan-15

70%

FL01 LMR

15-Sep-15

6-Jan-16

Done

4-Jan-16

22-Feb-16

40%

FL02 LMR

15-Sep-15

6-Jan-16

Done

4-Jan-16

22-Feb-16

90%

PL05-08 LMR

15-Sep-15

6-Jan-16

Done

4-Jan-16

22-Feb-16

50%

Booster Pump & Filtration Rm

30-Nov-15

6-Jan-16

Done

15-Jan-16

22-Feb-16

70%

Fire Pump Rm

10-Oct-15

6-Jan-16

Done

22-Feb-16

50%

PAHU Rm (GL Y8)

10-Oct-15

6-Jan-16

Done

5-Oct-15

22-Feb-16

30%

Fire Tank

10-Oct-15

6-Jan-16

Done

15-Jan-16

22-Feb-16

30%

Water Supply Tank

15-Dec-15

15-Jan-15

Done

10-Feb-16

16-Feb-15

75%

PAHU

10-Oct-15

23-Jan-16

Done

5-Oct-15

24-Feb-16

30%

Done
Done
Done
Done
Done
Done
Done

30-Sep-15
30-Sep-15

Done

30-Sep-15

20-Sep-15
10-Sep-15

10-Aug-15
30-Oct-15
30-Oct-15

30-Oct-15

QINGJIAN INTERNATIONAL (MYANMAR) GROUP DEVELOPMENT CO., LTD


22, U Chit Maung Housing, U Chit Maung Road, Tamwe, Yangon, Myanmar.
Tel: +95-1-554046 Fax: +95-1-554048

M&E Progress Report


PROGRESS REPORT FOR M&E SYSTEM (% Bi-WEEKLY WORK DONE) @ Sule Square Project
ELECTRICAL SYSTEM ELV SYSTEM
(%
work done)
(% work done)
1st & 2nd 3rd overa 1st & 2nd 3rd
Fix
Fix
ll
Fix
Fix

Storey

Basement-1

95%

Level 1

BMS SYSTEM

(% work done)
1st & 2nd 3rd
Fix
Fix

(% work done)
1st & 2nd 3rd
Fix
Fix

FIRE PROTECTION
(% work done)
1st & 2nd
Fix

3rd
Fix

PLUMBING

PA SYSTEM

SANITARY

(% work
(% work
(% work done)
1st & 2nd 3rd
1st & done)
2nd rd
1st &done)
2nd 3rd
3 Fix
Fix
Fix
Fix
Fix
Fix

DATE: 15-Mar-16
P&S
OVERALL
(%)

GAS

LIFT

ESC

OVERALL
(%)

95%

90%

86%

95%

86%

90%

86%

95%

90%

95%

90%

80%

89%

95%

80%

79%

95%

95%

80%

89%

90%

81%

90%

86%

85%

77%

90%

86%

95%

90%

95%

90%

20%

83%

80%

80%

72%

80%

95%

80%

83%

Level 2

80%

72%

80%

76%

85%

77%

90%

86%

80%

80%

80%

90%

81%

80%

80%

72%

80%

95%

50%

77%

Level 3

90%

82%

90%

86%

75%

68%

90%

86%

80%

80%

80%

90%

81%

80%

80%

72%

95%

78%

Level 4

90%

81%

90%

86%

80%

72%

90%

86%

90%

80%

90%

90%

81%

80%

80%

72%

95%

82%

Level 5

90%

82%

90%

86%

80%

72%

90%

86%

90%

90%

90%

90%

81%

80%

80%

72%

95%

82%

Level 6

90%

81%

90%

86%

80%

72%

90%

86%

90%

90%

90%

90%

81%

80%

80%

72%

95%

82%

Level 7

75%

68%

80%

76%

65%

59%

90%

86%

80%

80%

80%

90%

81%

80%

80%

72%

95%

73%

Level 8

65%

59%

65%

62%

70%

63%

90%

86%

70%

50%

69%

90%

81%

0%

95%

61%

Level 9

80%

72%

80%

76%

60%

54%

90%

86%

90%

80%

90%

90%

81%

80%

80%

72%

50%

75%

Level
Level
Level
Level
Level
Level
Level
Level
Level
Level
Level
Level
Level
Level

90%
90%
90%
90%
90%
80%
80%
45%
40%
40%
40%
20%
10%

81%
81%
81%
81%
81%
72%
72%
41%
36%
36%
36%
18%
9%
0%

90%
90%
90%
90%
90%
80%
80%
80%
80%
80%
80%
10%
10%

86%
86%
86%
86%
86%
76%
76%
76%
76%
76%
76%
10%
10%
0%

90%
80%
80%
80%
70%
80%
65%
70%
30%

81%
72%
72%
72%
63%
72%
59%
63%
27%
0%
0%
0%
0%
0%

90%
90%
90%
90%
90%
90%
90%
85%
85%
85%
85%
85%
85%
85%

86%
86%
86%
86%
86%
86%
86%
81%
81%
81%
81%
81%
81%
81%

90%
95%
90%
90%
85%
80%
90%
85%
70%
70%
50%

85%
85%
85%
85%
85%
80%
90%
60%
70%
70%
40%

90%
95%
90%
90%
85%
80%
90%
84%
70%
70%
50%
0%
10%
0%

90%
90%
90%
90%
90%
90%
90%
90%
90%
90%
90%
90%
90%
80%

81%
81%
81%
81%
81%
81%
81%
81%
81%
81%
81%
81%
81%
72%

80%
80%
80%
80%
80%
80%
80%
70%
70%
60%
50%
50%

80%
70%
70%
80%
80%
80%
80%
80%
80%
80%
80%
30%

72%
68%
68%
72%
72%
72%
72%
68%
68%
63%
59%
36%
0%
0%

50%
50%
50%
50%
50%
50%
50%
50%
50%
50%
50%
50%
50%
50%

83%
82%
81%
81%
78%
76%
77%
70%
58%
52%
45%
21%
19%
13%

10
11
12
13
14
15
16
17
18
19
20
21
22
23

90%

ACMV SYSTEM

10%
5%

Lower Roof

20%

62%

ELECTRICAL
1) 1ST FIX:
2) 2ND FIX:
3) FINAL FIX:

71%

10%

18%

54%

SYSTEM
conduit & the brackets, K.O box, etc
exposed conduit, trunking & wiring work, Isolator,DBs, etc
Lighting, power points, switches, etc..

ACMV SYSTEM
1) 1ST FIX:
Drain pipes, conduit, pipe sleeve, duct sleeve & brackets, pipe sleeve & support, etc
2) 2ND FIX:
exposed piping, ducting & wiring work, FCU, CU, MV FANs, Chiller, AHU & Cooling Tower, etc..
3) FINAL FIX: Grill, Louver, etc..

60%

84%

73%

81%

60%

FIRE PROTECTION SYSTEM


1) 1ST FIX:
conduit & the brackets, etc
2) 2ND FIX:
exposed piping & wiring work,Fire panel,HR, sprinkler head, etc
3) FINAL FIX: Lighting, power points, switches, etc..
PLUMBING &
1) 1ST FIX:
2) 2ND FIX:
3) FINAL FIX:

SANITARY SYSTEM
pipe sleeve & brackets, etc
exposed piping & wiring work, WC, Basin, Urinal bowl
Water tap, Spary shower, etc..

11%

69%

9%

67%

PLANT ROOM

Fuel Tank Chamber


Domestic Water Pump Rm
Ejector Pit
Sewage Treatment Room
HT Switch Room
Fire Pump Room
Diesel Pump Room
Gas Cylinder Room
MDF Room
Sprinkler Pump Room
IT Room

90%

Transformer Room
LV Switch Room
PAHU Room

95%
90%
70%

Chiller Room
Generator Room

80%
60%

Cooling Tower Room

85%

Lift Machine Room

70%

FL01 LMR
FL02 LMR
PL05-08 LMR
Booster Pump & Filtration Rm
Fire Pump Rm
PAHU Rm (GL Y8)
Fire Tank
Water Supply Tank
PAHU (GL Y4)

40%
90%
50%
70%
50%
30%
80%
75%
30%

20%
90%
95%
60%

30%
80%

QINGJIAN INTERNATIONAL (MYANMAR) GROUP DEVELOPMENT CO., LT


22, U Chit Maung Housing, U Chit Maung Road, Tamwe, Yangon, Myanmar.
Tel: +95-1-554046 Fax: +95-1-554048

PROGRESS REPORT F

Storey

ELECTRICAL SYSTEM ELV SYSTEM


(%
work done)
(% work done)
st
nd
rd
st
1 &2
3
overa 1 & 2nd 3rd
Fix
Fix
ll
Fix
Fix

Basement-1

95%

86%

Level 1

81%

86%

Level 2

72%

76%

Level 3

82%

86%

Level 4

81%

86%

Level 5

82%

86%

Level 6

81%

86%

Level 7

68%

76%

Level 8

59%

62%

Level 9

72%

76%

Level
Level
Level
Level
Level
Level
Level
Level
Level
Level
Level
Level
Level
Level

81%
81%
81%
81%
81%
72%
72%
41%
36%
36%
36%
18%
9%
0%

86%
86%
86%
86%
86%
76%
76%
76%
76%
76%
76%
10%
10%
0%

10
11
12
13
14
15
16
17
18
19
20
21
22
23

Lower Roof

ELECTRICAL
1) 1ST FIX:
2) 2ND FIX:
3) FINAL FIX:

SYSTEM
conduit & the brackets, K.O box, etc
exposed conduit, trunking & wiring work, Isolator,DBs, etc
Lighting, power points, switches, etc..

ACMV SYSTEM
1) 1ST FIX:
Drain pipes, conduit, pipe sleeve, duct sleeve & brackets, pipe sle

2) 2ND FIX:
3) FINAL FIX:

exposed piping, ducting & wiring work, FCU, CU, MV FANs, Chille
Grill, Louver, etc..

OPMENT CO., LTD


angon, Myanmar.

M&E Progress Report

ESS REPORT FOR M&E SYSTEM (% Bi-WEEKLY WORK DONE) @ Sule S


ACMV SYSTEM

BMS SYSTEM

(% work done)
1 & 2nd 3rd
Fix
Fix

(% work done)
1 & 2nd 3rd
Fix
Fix

st

st

FIRE PROTECTION
(% work done)
1st & 2nd
Fix

86%

86%

95%

77%

86%

95%

77%

86%

80%

68%

86%

80%

72%

86%

90%

72%

86%

90%

72%

86%

90%

59%

86%

80%

63%

86%

70%

54%

86%

90%

81%
72%
72%
72%
63%
72%
59%
63%
27%
0%
0%
0%
0%
0%

86%
86%
86%
86%
86%
86%
86%
81%
81%
81%
81%
81%
81%
81%

90%
95%
90%
90%
85%
80%
90%
85%
70%
70%
50%

20%

tor,DBs, etc

& brackets, pipe sleeve & support, etc

10%

U, MV FANs, Chiller, AHU & Cooling Tower, etc..

K DONE) @ Sule Square Project

RE PROTECTION
(% work done)
3rd
Fix

PLUMBING

PA SYSTEM

(% work
(% work done)
1st & 2nd 3rd
1st & done)
2nd rd
3 Fix
Fix
Fix
Fix

90%

95%

90%

80%

89%

95%

90%

95%

90%

20%

83%

80%

80%

80%

90%

81%

80%

80%

80%

90%

81%

80%

80%

90%

90%

81%

80%

90%

90%

90%

81%

80%

90%

90%

90%

81%

80%

80%

80%

90%

81%

80%

50%

69%

90%

81%

80%

90%

90%

81%

80%

85%
85%
85%
85%
85%
80%
90%
60%
70%
70%
40%

90%
95%
90%
90%
85%
80%
90%
84%
70%
70%
50%
0%
10%
0%

90%
90%
90%
90%
90%
90%
90%
90%
90%
90%
90%
90%
90%
80%

81%
81%
81%
81%
81%
81%
81%
81%
81%
81%
81%
81%
81%
72%

80%
80%
80%
80%
80%
80%
80%
70%
70%
60%
50%
50%

FIRE PROTECTION SYSTEM


1) 1ST FIX:
conduit & the brackets, etc
2) 2ND FIX:
exposed piping & wiring work,Fire panel,HR, sprin
3) FINAL FIX: Lighting, power points, switches, etc..
PLUMBING & SANITARY SYSTEM
1) 1ST FIX:
pipe sleeve & brackets, etc

2) 2ND FIX:
3) FINAL FIX:

exposed piping & wiring work, WC, Basin, Urinal


Water tap, Spary shower, etc..

SANITARY
(% work
1st &done)
2nd 3rd
Fix
Fix

DATE: 15-Mar-16
P&S
OVERALL
(%)

GAS

LIFT

ESC

OVERALL
(%)

80%

79%

95%

95%

80%

89%

80%

72%

80%

95%

80%

83%

80%

72%

80%

95%

50%

77%

80%

72%

95%

78%

80%

72%

95%

82%

80%

72%

95%

82%

80%

72%

95%

82%

80%

72%

95%

73%

0%

95%

61%

80%

72%

50%

75%

80%
70%
70%
80%
80%
80%
80%
80%
80%
80%
80%
30%

72%
68%
68%
72%
72%
72%
72%
68%
68%
63%
59%
36%
0%
0%

50%
50%
50%
50%
50%
50%
50%
50%
50%
50%
50%
50%
50%
50%

83%
82%
81%
81%
78%
76%
77%
70%
58%
52%
45%
21%
19%
13%

ork,Fire panel,HR, sprinkler head, etc


witches, etc..

60%

work, WC, Basin, Urinal bowl

PLANT ROOM

Fuel Tank Chamber


Domestic Water Pump Rm
Ejector Pit
Sewage Treatment Room
HT Switch Room
Fire Pump Room
Diesel Pump Room
Gas Cylinder Room
MDF Room
Sprinkler Pump Room
IT Room

90%

Transformer Room
LV Switch Room
PAHU Room

95%
90%
70%

20%
90%
95%
60%

30%
80%

Chiller Room
Generator Room

80%
60%

Cooling Tower Room

85%

Lift Machine Room

70%

FL01 LMR
FL02 LMR
PL05-08 LMR
Booster Pump & Filtration Rm
Fire Pump Rm
PAHU Rm (GL Y8)
Fire Tank
Water Supply Tank
PAHU (GL Y4)

40%
90%
50%
70%
50%
30%
80%
75%
30%

Factors considered for scheduling MEP Milestone Date:

1) Every floors are not linked together. The Sub-contractors need to provide separate team
every floors.

2) The critical path is at Lower Roof. 1st & 2nd fix require 45 days to complete because ma

room & equipment are at this level. The MEP installation completion date is targeted on

4 Feb 2016. Due to the congested area, the programme could not be compressed any m

3) The Testing & Commissioning period is less than 2 months. Saperate teams to complete
T&C activities is necessary and only one way to complete by end March.

ovide separate team for

mplete because many plant

n date is targeted on

e compressed any more.


teams to complete the

MEP Progress

Floor

B1

L1

L2

L3

L4

L5

L6

L7

L8

Trades

Overall
ACMV
BMS
Fire Service
Electrical
ELV
PS
Overall
ACMV
BMS
Fire Service
Electrical
ELV
PS
Overall
ACMV
BMS
Fire Service
Electrical
ELV
PS
Overall
ACMV
BMS
Fire Service
Electrical
ELV
PS
Overall
ACMV
BMS
Fire Service
Electrical
ELV
PS
Overall
ACMV
BMS
Fire Service
Electrical
ELV
PS
Overall
ACMV
BMS
Fire Service
Electrical
ELV
PS
Overall
ACMV
BMS
Fire Service
Electrical
ELV
PS
Overall
ACMV
BMS
Fire Service
Electrical
ELV

1st & 2nd Fix

Final Fix

Structural
Completion
Date
(Revised
Schedule)

Overall Structural
/ Architectural
Clearance Issued

Start Date

Target
Completion
Date

Done

Done

Started

21-Aug-15

2-Nov-15

Done

Done

Started

28-Aug-15

5-Nov-15

1-Jun-15

27-Jul-15

3-Aug-15

2-Oct-15

8-Nov-15

12-Jun-15

15-Aug-15

17-Aug-15

16-Sep-15

11-Nov-15

23-Jun-15

22-Aug-15

24-Aug-15

23-Sep-15

14-Nov-15

4-Jul-15

29-Aug-15

31-Aug-15

30-Sep-15

17-Nov-15

15-Jul-15

5-Sep-15

7-Sep-15

7-Oct-15

20-Nov-15

26-Jul-15

12-Sep-15

14-Sep-15

13-Nov-15

23-Nov-15

4-Aug-15

19-Sep-15

21-Sep-15

21-Oct-15

26-Nov-15

Actual
Completion (%)

Target
Completion
Date

MEP Progress

Floor
L8

L9

L10

L11

L12

Trades

PS
Overall
ACMV
BMS
Fire Service
Electrical
ELV
PS
Overall
ACMV
BMS
Fire Service
Electrical
ELV
PS
Overall
ACMV
BMS
Fire Service
Electrical
ELV
PS
Overall
ACMV
BMS
Fire Service
Electrical
ELV
PS

1st & 2nd Fix

Final Fix

Structural
Completion
Date
(Revised
Schedule)

Overall Structural
/ Architectural
Clearance Issued

Start Date

Target
Completion
Date

15-Aug-15

5-Sep-15

7-Sep-15

7-Oct-15

29-Nov-15

24-Aug-15

14-Sep-15

16-Sep-15

16-Oct-15

2-Dec-15

4-Sep-15

25-Sep-15

27-Sep-15

27-Oct-15

5-Dec-15

14-Sep-15

5-Oct-15

7-Oct-15

6-Nov-15

8-Dec-15

Actual
Completion (%)

Target
Completion
Date

MEP Progress

Floor

L13

L14

L15

L16

L17

L18

L19

L20

L21

Trades

Overall
ACMV
BMS
Fire Service
Electrical
ELV
PS
Overall
ACMV
BMS
Fire Service
Electrical
ELV
PS
Overall
ACMV
BMS
Fire Service
Electrical
ELV
PS
Overall
ACMV
BMS
Fire Service
Electrical
ELV
PS
Overall
ACMV
BMS
Fire Service
Electrical
ELV
PS
Overall
ACMV
BMS
Fire Service
Electrical
ELV
PS
Overall
ACMV
BMS
Fire Service
Electrical
ELV
PS
Overall
ACMV
BMS
Fire Service
Electrical
ELV
PS
Overall
ACMV
BMS
Fire Service
Electrical
ELV

1st & 2nd Fix

Final Fix

Structural
Completion
Date
(Revised
Schedule)

Overall Structural
/ Architectural
Clearance Issued

Start Date

Target
Completion
Date

21-Sep-15

12-Oct-15

14-Oct-15

13-Nov-15

11-Dec-15

28-Sep-15

19-Oct-15

21-Oct-15

20-Nov-15

14-Dec-15

5-Oct-15

26-Oct-15

28-Oct-15

27-Nov-15

17-Dec-15

12-Oct-15

2-Nov-15

4-Nov-15

4-Dec-15

20-Dec-15

19-Oct-15

9-Nov-15

11-Nov-15

11-Dec-15

23-Dec-15

25-Oct-15

15-Nov-15

17-Nov-15

17-Dec-15

26-Dec-15

31-Oct-15

21-Nov-15

23-Nov-15

23-Dec-15

29-Dec-15

6-Nov-15

27-Nov-15

29-Nov-15

29-Dec-15

1-Jan-16

12-Nov-15

3-Dec-15

5-Dec-15

4-Jan-16

9-Jan-16

Actual
Completion (%)

Target
Completion
Date

MEP Progress

Floor
L21

L22

L23

Lower Roof

Trades

PS
Overall
ACMV
BMS
Fire Service
Electrical
ELV
PS
Overall
ACMV
BMS
Fire Service
Electrical
ELV
PS
Overall
ACMV
BMS
Fire Service
Electrical
ELV
PS

1st & 2nd Fix

Final Fix

Structural
Completion
Date
(Revised
Schedule)

Overall Structural
/ Architectural
Clearance Issued

Start Date

Target
Completion
Date

18-Nov-15

9-Dec-15

11-Dec-15

10-Jan-16

15-Jan-16

24-Nov-15

15-Dec-15

17-Dec-15

16-Jan-16

21-Jan-16

30-Nov-15

21-Dec-15

23-Dec-15

6-Feb-16

11-Feb-16

Actual
Completion (%)

Target
Completion
Date

MEP Progress

Floor

B1

L1

L2

L3

L4

L5

L6

L7

L8

Trades

Overall
ACMV
BMS
Fire Service
Electrical
ELV
PS
Overall
ACMV
BMS
Fire Service
Electrical
ELV
PS
Overall
ACMV
BMS
Fire Service
Electrical
ELV
PS
Overall
ACMV
BMS
Fire Service
Electrical
ELV
PS
Overall
ACMV
BMS
Fire Service
Electrical
ELV
PS
Overall
ACMV
BMS
Fire Service
Electrical
ELV
PS
Overall
ACMV
BMS
Fire Service
Electrical
ELV
PS
Overall
ACMV
BMS
Fire Service
Electrical
ELV
PS
Overall
ACMV
BMS
Fire Service
Electrical
ELV

1st & 2nd Fix

Final Fix

Structural
Completion
Date
(Revised
Schedule)

Overall Structural
/ Architectural
Clearance Issued

Start Date

Target
Completion
Date

Done

Done

Started

21-Aug-15

2-Nov-15

Done

Done

Started

28-Aug-15

5-Nov-15

1-Jun-15

27-Jul-15

3-Aug-15

2-Oct-15

8-Nov-15

12-Jun-15

15-Aug-15

17-Aug-15

16-Sep-15

11-Nov-15

23-Jun-15

22-Aug-15

24-Aug-15

23-Sep-15

14-Nov-15

4-Jul-15

29-Aug-15

31-Aug-15

30-Sep-15

17-Nov-15

15-Jul-15

5-Sep-15

7-Sep-15

7-Oct-15

20-Nov-15

26-Jul-15

12-Sep-15

14-Sep-15

13-Nov-15

23-Nov-15

4-Aug-15

19-Sep-15

21-Sep-15

21-Oct-15

26-Nov-15

Actual
Completion (%)

Target
Completion
Date

Actual
Completion (%)

MEP Progress

Floor
L8

L9

L10

L11

L12

Trades

PS
Overall
ACMV
BMS
Fire Service
Electrical
ELV
PS
Overall
ACMV
BMS
Fire Service
Electrical
ELV
PS
Overall
ACMV
BMS
Fire Service
Electrical
ELV
PS
Overall
ACMV
BMS
Fire Service
Electrical
ELV
PS

1st & 2nd Fix

Final Fix

Structural
Completion
Date
(Revised
Schedule)

Overall Structural
/ Architectural
Clearance Issued

Start Date

Target
Completion
Date

15-Aug-15

5-Sep-15

7-Sep-15

7-Oct-15

29-Nov-15

24-Aug-15

14-Sep-15

16-Sep-15

16-Oct-15

2-Dec-15

4-Sep-15

25-Sep-15

27-Sep-15

27-Oct-15

5-Dec-15

14-Sep-15

5-Oct-15

7-Oct-15

6-Nov-15

8-Dec-15

Actual
Completion (%)

Target
Completion
Date

Actual
Completion (%)

MEP Progress

Floor

L13

L14

L15

L16

L17

L18

L19

L20

L21

Trades

Overall
ACMV
BMS
Fire Service
Electrical
ELV
PS
Overall
ACMV
BMS
Fire Service
Electrical
ELV
PS
Overall
ACMV
BMS
Fire Service
Electrical
ELV
PS
Overall
ACMV
BMS
Fire Service
Electrical
ELV
PS
Overall
ACMV
BMS
Fire Service
Electrical
ELV
PS
Overall
ACMV
BMS
Fire Service
Electrical
ELV
PS
Overall
ACMV
BMS
Fire Service
Electrical
ELV
PS
Overall
ACMV
BMS
Fire Service
Electrical
ELV
PS
Overall
ACMV
BMS
Fire Service
Electrical
ELV

1st & 2nd Fix

Final Fix

Structural
Completion
Date
(Revised
Schedule)

Overall Structural
/ Architectural
Clearance Issued

Start Date

Target
Completion
Date

21-Sep-15

12-Oct-15

14-Oct-15

13-Nov-15

11-Dec-15

28-Sep-15

19-Oct-15

21-Oct-15

20-Nov-15

14-Dec-15

5-Oct-15

26-Oct-15

28-Oct-15

27-Nov-15

17-Dec-15

12-Oct-15

2-Nov-15

4-Nov-15

4-Dec-15

20-Dec-15

19-Oct-15

9-Nov-15

11-Nov-15

11-Dec-15

23-Dec-15

25-Oct-15

15-Nov-15

17-Nov-15

17-Dec-15

26-Dec-15

31-Oct-15

21-Nov-15

23-Nov-15

23-Dec-15

29-Dec-15

6-Nov-15

27-Nov-15

29-Nov-15

29-Dec-15

1-Jan-16

12-Nov-15

3-Dec-15

5-Dec-15

4-Jan-16

9-Jan-16

Actual
Completion (%)

Target
Completion
Date

Actual
Completion (%)

MEP Progress

Floor
L21

L22

L23

Lower Roof

Trades

PS
Overall
ACMV
BMS
Fire Service
Electrical
ELV
PS
Overall
ACMV
BMS
Fire Service
Electrical
ELV
PS
Overall
ACMV
BMS
Fire Service
Electrical
ELV
PS

1st & 2nd Fix

Final Fix

Structural
Completion
Date
(Revised
Schedule)

Overall Structural
/ Architectural
Clearance Issued

Start Date

Target
Completion
Date

18-Nov-15

9-Dec-15

11-Dec-15

10-Jan-16

15-Jan-16

24-Nov-15

15-Dec-15

17-Dec-15

16-Jan-16

21-Jan-16

30-Nov-15

21-Dec-15

23-Dec-15

6-Feb-16

11-Feb-16

Actual
Completion (%)

Target
Completion
Date

Actual
Completion (%)

You might also like