YANANGENERATION

POWER

CHINESE WELL-KNOWN TRADEMARK


NEW ERA SLG 162, 182
SERIES BRUSHLESS SYNCHRONOUS ALTERNATOR(2 Pole)
NEW ERA SLG SERIES MODEL & POWER
Prime Output Prime Output
THREE-PHASE BRUSHLESS SYNCHRONOUS ALTERNATOR Model
KW KVA KW KVA
MODEL & POWER (Single phase,230V,3000rpm,50Hz) Single phase,230V,3600rpm,60Hz
Prime Output(1500rpm/50Hz)400V Prime Output(1800rpm/60Hz)440V SLG162D 8.4 8.4 10 10
Model SLG162E 10 10 12.4 12.4
KW KVA KW KVA
SLG162F 11.8 11.8 14.4 14.4
SLG164A 6.5 8.1 8.2 10.3
SLG164B 8.8 11.0 11 13.8 SLG162G 16.8 16.8 20.6 20.6
SLG164C 10.8 13.5 13.5 16.9 SLG182H 20 20 24.8 24.8
SLG164D 12.8 16 16 20
SLG182J 23.5 23.5 28.9 28.9
SLG184E 18 22.5 23 28.8
SLG184F 22 27.5 27.5 34.4 SLG182k 25 25 31 31
SLG184G 25 31.3 30 37.5 3 phase,400V,3000rpm,50Hz 3 phase,400V,3600rpm,60Hz
SLG184H 30 37.5 37.5 46.9
SLG162D 10 12.5 11.8 14.7
SLG184J 32 40 40 50
SLG224C 34 42.5 42 52.5 SLG162E 12 15 14.2 17.8
SLG224D 40 50 50 62.5 SLG162F 14 17.5 16.6 20.8
SLG224E 48 60 56 70
SLG162G 20 25 23.7 29.6
SLG224F 58 72.5 70 87.5
SLG224G 68 85 78 97.5 SLG182H 24 30 28.3 35.4
SLG274C 80 100 94 118 SLG182J 26.8 33.5 33 41.3
SLG274D 91 114 110 138
SLG182k 30 37.5 35.5 44.4
SLG274E 112 140 134 168
SLG274F 128 160 152 190 SLG182L 32 40 40 50
SLG274G 140 175 170 213
SLG274H 160 200 196 245
SLG274J 184 230 224 280
SLG274K 200 250 235 294
SLG314C 200 250 235 294
SLG314D 236 295 280 350
SLG314E 260 325 315 394
SLG314F 304 380 365 456
SLG314G 320 400 380 475
SLG354C 360 450 440 550
SLG354D 400 500 475 594
SLG354E 480 600 570 713
SLG354F 536 670 620 775
SLG404A 600 750 640 800
SLG404G 640 800 720 900
SLG404H 720 900 800 1000
SLG404J
SLG404K
800
900
1000
1125
900
1000
1125
1250 TWG SERIES
SLG454S 930 1163 1070 1338 BRUSHLESS SYNCHRONOUS ALTERNATOR
SLG454A 1008 1260 1220 1525
SLG454B 1120 1400 1352 1690 MODEL & POWER
SLG454C 1240 1550 1512 1890 Prime Output Prime Output Prime Output Prime Output
SLG454D 1320 1650 1612 2015 Model Model Model Model
KW KVA KW KVA KW KVA KW KVA
SLG454E 1520 1900 1840 2300
TWG224A 24 30 TWG224H 68 85 TWG274G 140 175 TWG314F-1 304 380
SLG454F 1664 2080 2080 2600
TWG224B 30 37.5 TWG274C 75 94 TWG274H 150 187.5 TWG354C 350 437.5
SLG454G 1760 2200 2200 2750
TWG224C 34 42.5 TWG274C-1 80 100 TWG274H-1 160 200 TWG354C-1 360 450
SLG564C 1850 2313 2130 2663
SLG564D 2100 2625 2410 3013 TWG224D 40 50 TWG274D 91 114 TWG314C 200 250 TWG354D 400 500
SLG564E 2500 3125 2870 3588 TWG224E 48 60 TWG274D-1 100 125 TWG314D 236 295 TWG354E 450 562.5
SLG564F 2800 3500 3220 4025 TWG224E-1 50 62.5 TWG274E 112 140 TWG314E 250 312.5 TWG354E-1 480 600
SLG564G 3000 3750 3500 4375 TWG224F 58 72.5 TWG274F 120 150 TWG314E-1 260 325 TWG354F 500 625
SLG564H 2720(480V) 3400(480V) 2880(480V) 3600(480V) TWG224G 64 80 TWG274F-1 128 160 TWG314F 300 375 TWG354F-1 536 670
TFW2 SERIES
BRUSHLESS SYNCHRONOUS ALTERNATOR
MODEL & POWER
Model Prime Model Prime Model Prime Model Prime
Output Output Output Output
TFW2 -2 2 TFW2 -10 10 TFW 2 -24 24 TFW 2 -64 64
TFW2 -3 3 TFW2 -12 12 TFW 2 -30 30 TFW 2 -75 75
TFW2 -5 5 TFW2 -15 15 TFW 2 -40 40
TS & TSC SERIES
TFW2 -7.5 7.5 TFW2 -20 20 TFW 2 -50 50 BRUSH & BRUSHLESS ALTERNATOR
FEATURES:
Integral type rotor design prevent winding shaking off.
Roll steel housing, attractive design.
Built in AVR to ensure steady voltage and high performance
Freely interchangeable between bush and bushless
MODEL & POWER
Model
Single phase TS-3 TS-5 TS-8 TS-10 TS-12 TS-15 TS-20 TS-24 TS-30

Prime Output 3KW 5KW 8KW 10KW 12KW 15KW 20KW 24KW 30KW

Model
Three phase TSC-5 TSC-8 TSC-10 TSC-12 TSC-15 TSC-20 TSC-24 TSC-30 TSC-40 TSC-50 TSC-64 TSC-80

Prime Output 5KW 8KW 10KW 12KW 15KW 20KW 24KW 30KW 40KW 50KW 64KW 80KW

SLI SERIES
2 POLES SYNCHRONOUS ALTERNATOR
SINGLE PHASE THREE PHASE
50Hz-3000r.p.m 60Hz-3600r.p.m 50Hz-3000r.p.m 60Hz-3600r.p.m
4/4 4/4 Model
Model Prime Output cos =1 Model Prime Output cos =1 Prime Output cos 4/4
=0.8
Model Prime Output 4/4
cos =0.8
(KVA) % (KVA) % (KVA) % (KVA) %
SLI-5 5 78 SLI-5 5 78 SLI-5.5 5.5 78 SLI-6.5 6.5 79
SLI-6 6 79 SLI-6 6 79 SLI-7 7 80 SLI-8 8 81
SLI-7 7 80 SLI-7 7 80 SLI-8.5 8.5 81 SLI-10 10 82
SLI-8 8 81 SLI-8 8 81 SLI-10 10 82 SLI-12 12 84

GA SERIES ST & STC SERIES


SINGLE OR THREE PHASE BRUSH ALTERNATOR
2 POLES BRUSHLESS ALTERNATOR
MODEL & POWER
Prime Output(KVA)
Model Model ST-2 ST-3 ST-5 ST-7.5 ST-10 ST-12 ST-15 ST-20 ST-30
50Hz/3000rpm 60Hz/3600rpm
Prime Output 2kW 3kW 5kW 7.5kW 10kW 12kW 15kW 20kW 30kW
GA2509SA 8 10

GA2511SC 12 15 Model STC-3 STC-5 STC-7.5 STC-10 STC-12 STC-15 STC-20 STC-24 STC-30 STC-40 STC-50 STC-64 STC-75 STC-100 STC-120

GA2518SA 16 20 Prime Output 3kW 5kW 7.5kW 10kW 12kW 15kW 20kW 24kW 30kW 40kW 50kW 64kW 75kW 100kW 120kW
SLH SERIES
WELDING ALTERNATOR
FEATURES:
COMBINING GENERATOR WITH WELDER, OUR DUAL FUNCTION MACHINE IS AN
IDEA PRODUCT TO HELP YOU PLANNING YOUR BUDGET.
DUAL UTILIZATION
The generating and welding can be operated at same time to improve performance and
working efficiency. The voltage and waveform won't be effected while welding.
EXCELLENT PERFORMANCE OF WELDING
An rectifying technology has been adopted to convert the intermediate frequency
Alternating Current into Direct Current which brings the welding Arc easily generated,
thus the Steady welding & smooth welded-joint.
HIGH EFFICIENCY POWER
Adopting an intermediate frequency permanent-magnetic and invert technology
EASY OPERATION
Light & Compact design improves the performance in the working site.
COMPREHESIVE APPLICATIONS:
Easy to generate the Arc.
Stable electric arc
The welding current can be adjusted in wide range.

SFPW SERIES
Can be used in diferrent circumstances and various size of welding rod, which helps the
welding in operator's element.

OF PERMANENT-MAGNET DC ARC-WELDING ALTERNATOR Model Alternator Prime Output(KVA) Rate welding current

Model SFPW-160 SFPW-180 SFPW-200 SFPW-250 SFPW-300 SLH11-160 1 160A


SLH11-200 1 200A
Prime Output 1.5KW 1.6KW 1.8KW 1.8KW 2.2KW
SLH25-300 2 300A
Welding Ampe 160A 180A 200A 250A 300A SLH25-400 2 400A
SLH25-500 2 500A

SLD SERIES
SINGLE OR THREE PHASE DIGITAL ALTERNATOR
LIGHT & COMPACT
Comparing with traditional Generators, the weight and overall
dimension of digital generator will be less 30% to 50% by using high
efficiency and multi-pole permanent magnetic generators.

HIGH EFFICIENCY POWER


The Inverter technology provides the high efficiency power.
ENERGY SAVING
With YANAN "Intelligent Energy Saving Module", the speed of engine
is automaticly adjusted according to real load, which results in low fuel
consumption and durable use.
SILENT

SLY SERIES
The use of "Intelligent Energy Saving Module" can effectively reduce
the noise-level when light load.
PARALLEL FUNCTION WINDMILL ALTERNATOR
A double output can be provided by a simple device to connect two
inverter generators TECHNICAL DATA
Overall dimension
Model Prime Output (KW) Voltage(V) Speed (RPM) Hertz Model Prime Output (KW) Rate speed (RPM) Resistance torque (Nm) Pole Generator output voltage
(LxWxH)mm

SLD-6 6 SLY-0.3 0.3 400 1.5 12 3Phase AC30V-240V 220x220x140


SLY-0.5 0.5 350 2.0 12 3Phase AC30V-240V 220x220x155
SLD-8 8 SLY-0.6 0.6 350 2.5 12 3Phase AC30V-240V 220x220x165
1200-3000 SLY-1 1 300 3.0 12 3Phase AC30V-240V 220x220x235
SLD-10 10
SLY-2 2 350 3.5 16 3Phase AC30V-240V 410x410x148
SLD-12 12 Single or three SLY-3.75 3.75 300 4.0 16 3Phase AC30V-240V 410x410x186
phase depend on SLY-4 4 160 4.5 16 3Phase AC30V-240V 410x410x224
SLD-15 15 Inverter type
50Hz or 60Hz SLY-5 5 180 5.0 16 3Phase AC30V-240V 410x410x246
120/240v
SLD-20 20 230v SLY-5 5 150 5.0 16 3Phase AC30V-240V 600x600x190
400v SLY-5.5 5.5 140 5.0 24 3Phase AC30V-240V 600x600x210
SLD-25 25 SLY-7.5 7.5 120 6.0 24 3Phase AC60V-350V 600x600x260
1000-2500 SLY-10 10 110 9.0 24 3Phase AC60V-350V 600x600x340
SLD-30 30
SLY-15 15 100 11.0 40 3Phase AC60V-350V 910x910x230
SLD-34 34 SLY-20 20 100 12.0 40 3Phase AC60V-400V 910x910x310
SLY-50 50 100 20.0 40 3Phase AC60V-500V 910x910x595
SLD-40 40
SLY-100 100 100 25.0 40 3Phase AC60V-500V 910x910x764
SLTD SERIES
PERMANENT MAGNET THREE-PHASE SYNCHRONOUS MOTOR
SPECIALLY FOR HYBRID POWER VEHICLE
SLTD11-30 MAIN SPECIFICATION SLCD16-18 SERIES
Prime Output 30KW Peak torque 150N.m SYNCHRONOUS ALTERNATOR FOR HYBRID POWER VEHICLE
Battery voltage 288V Outline dimension 203X260mm SLCD16-18 Synchronous alternator can gather the remained energy from Hybrid Power Vehicle and drive
Rating speed 3770RPM Working speed 0-5000 the motor to move Vehicle , and thus achieve requirements of energy saving & environmental protection.

Power efficiency 96% Connection Y


MAIN SPECIFICATION
Rating frequency 377HZ Rated torque 75N.m
Prime Output Voltage Current Speed Protection Insulation
Model (V) (A) Phase Power Factor (r/min)
SLTD13-30 MAIN SPECIFICATION KVA class class

Prime Output 30KW Peak torque 150N.m 1


SLCD16-13 13 270 32 3 (advanced) 1500 IP55 H
Battery voltage 288V Outline dimension 228X230mm
1
Rating speed 3770RPM Working speed 0-5000RPM SLCD16-18 18 270 44.2 3 1500 IP55 H
(advanced)
Power efficiency 96% Connection Y
Besides, on customer s request, the products with special specifications are available.
Rating frequency 188.5HZ Rated torque 75N.m

SLTD25-65 MAIN SPECIFICATION


Prime Output 65KW Peak torque 650N.m
Battery voltage 288V Outline dimension 446X369mm
Rating speed 2000RPM Working speed 0-2500RPM
Power efficiency 96% Connection Y
Rating frequency 266.7HZ Rated torque 310N.m

YCF SERIES
SINGLE OR THREE PHASE PERMANENT-MAGNET ALTERNATOR

SINGLE PHASE

SLCD11-13 SERIES Model YCF-3 YCF-4 YCF-5 YCF-6

SYNCHRONOUS CONVERSION ALTERNATOR FOR VEHICLE AIR CONDITIONER Prime Output


SLCD11-13 Synchronous Conversion Alternator is an ideal and real-time power source for Vehicle Air Conditioner KW 3 4 5 6
with features of high efficiency,energy saving, environmental protection, quiet, low vibration, high output

MAIN SPECIFICATION THREE PHASE


Model Prime Output Voltage Current Phase Power Factor Speed Protection Insulation
KVA (V) (A) (r/min) class class Model YCF-3 YCF-4 YCF-5 YCF-6 YCF-8
1
SLCD11-13 13 400 18.8 3 (advanced) 4000 IP55 H
Prime Output
KW 3 4 5 6 8
Note: Except the specifications mentioned above, the order with special specifications is negotiable
ZPD/ZP SERIES
400HERTZ brushless alternators provide superior transient and steady
state output conform to the latest MIL-STD requirements
FEATURES:
3kW-120kW brushless , externally regulated ,12leads design.
No-load voltage setting range: 95% 105% of rated voltage
Steady-state voltage regulation rate: l%
Transient voltage regulation rate: 15% or 20%.
Voltage setting time: 0.5s

SLC SERIES
Voltage fluctuation rate: 0.5%
Wave form deviation
1% regulation and line droop compensation standard;
BRUSHLESS ALTERNATOR Standard: GB755-2008,GJB1213-91,GJB181-86,GJB549-88,ISO6858.

TECHNICAL DATA
TECHNICAL DATA
Model Prime Output (kW) Voltage(V) Current(A) Speed(RPM) Frequency(Hz)
Prime Output Voltage Current Power factor Phase Frequency Speed
Model (V) (A) (lag) (Hz) (rpm)
SLC164C 10 400 18 1500 50 (kW) number
SLC164D 12 400 21.6 1500 50 ZPD16A-16 3 208 14.4 1 1 400 3000
SLC164E 16 400 28.9 1500 50 ZPD16B-16 5.5 208 26.4 1 1 400 3000
SLC164F 18 400 32.5 1500 50 ZPD16C-16 8 208 38.5 1 1 400 3000
20 ZPD16D-16 10 208 48 1 1 400 3000
SLC164G 400 36 1500 50
ZP16C-12 10 208 34.7 0.8 3 400 4000
SLC164H 24 400 43.3 1500 50
ZP16D-12 15 208 52 0.8 3 400 4000
SLC164J 30 400 54.4 1500 50 ZP16E-12 20 208 69.4 0.8 3 400 4000
ZP16B-16 5.5 208 19 0.8 3 400 3000
ZP16C-16 8 208 27.8 0.8 3 400 3000
ZP16D-16 10 208 34.5 0.8 3 400 3000
ZP28A-24 30 208 104.1 0.8 3 400 2000
ZP28B-24 40 208 138.8 0.8 3 400 2000
ZP28C-24 50 208 173.5 0.8 3 400 2000
ZP28D-24 60 208 208.2 0.8 3 400 2000
ZP28E-24 70 208 242.9 0.8 3 400 2000
ZP28F-24 120 208 416.4 0.8 3 400 2000
ZP31A-32 50 200 180.4 0.8 3 400 1500
ZP31B-32 75 200 270.6 0.8 3 400 1500
ZP31C-32 100 200 360.9 0.8 3 400 1500

SP SERIES
50HERTZ AND 400HERTZ DUAL FREQUENCY BRUSHLESS ALTERNATOR
SP series dual frequency alternators can output 380V-440V/50HZ and 200-480V/400Hz

SLT SERIES
power together. Consist of two alternators in one shaft.

FEATURES:
RARE-EARTH PERMANENT MAGNETIC ALTERNATOR
Steady-state voltage regulation rate not more than 1%.
1.Adopt advanced permanent magnetic generating technology, sine waveform.
Transient voltage regulation rate not more than 15% or 20% setting time not
2. Smooth voltage waveform, small distortion, Voltage distortion factor (THD) 2%
more than 0.5S, When mutation rated power load.
3.No excitation winding, with small dissipation, Generating efficiency over 95%.
4.Adopt the rare-earth materials. 5.Compact, Small and Light. Totally-enclosed bearing.
6.No exciting winding, slip-ring and electrical brush, with the advantages of structure Simple, running reliable. Double bearing support or single bearing support
Standard: GB755-2008,GJB1213-91,GJB181-86,GJB549-88,ISO6858."
TECHNICAL DATA
Model Prime Output (KW) Current(A) Speed(RPM) Voltage(V) Pole Overall dimension(L W H)mm TECHNICAL DATA
SLT-5 5 7.2 1500 400 4 390 305 415
Power frequency output Medium frequency output
SLT-7.5 7.5 10.8 1500 400 4 390 305 415 Prime Power Prime Power
Model Voltage Current Phase Frequency Voltage Current Phase Frequency Speed
Output factor Output factor
SLT-10 10 14.4 1500 400 4 420 305 415 (kW) (V) (A) (lag) number (Hz) (kW) (V) (A) (lag) number (Hz) (rpm)
SLT-12 12 17.3 1500 400 4 425 335 450 SP31A-32 12 380 22.8 0.8 3 50 50 200 180.4 0.8 3 400 1500
SLT-15 15 21.6 1500 400 4 425 335 450 SP31B-32 12 380 22.8 0.8 3 50 75 200 270.6 0.8 3 400 1500
SLT-20 20 28.8 1500 400 4 460 335 450 SP31C-32 20 380 38.0 0.8 3 50 100 200 360.9 0.8 3 400 1500