e. Concise Beam
f. Presto Program
h. SEC SPECIFICATIONS .
1.3.0. DOCUMENTS & DRAWINGS :
1.3.1. DOCUMENTS :
a. Copies from references.
b. Any supplier specifications for material for the inserts element in the precast.
f'c
f'c
f'ci
f'ci
1.4.2.0 REINFORCEMENT :
grade of reinforcement steel
ASTM A615M
420 MPa
ASTM A496M
460 MPa
=
=
ASTM A36
250 MPa
1.4.3.0 STRANDS :
Pre-stressing strands shall be uncoated seven wire low relaxation strands conforming to ASTM
A416-80,
grade 270, having the following properties:
Ultimate Strength
1860 MPa
Modulus of Elasticity
186000 MPa
0.74 x1860
= 1376.4 MPa
15.2 mm
Nominal Area
140 mm
140 x 1376
= 193 kN
0.6 x1860
= 1116 MPa
12.7 mm
Nominal Area
98.7 mm
98.7 x 1116
= 110 kN
0.6 x1860
= 1116 MPa
9.53 mm
Nominal Area
54.8 mm
54.8 x 1116
= 61 kN
31.5 MPa
Eci
4700 x
0.6 x f'ci
0.6 x 31.5
(f'ci)/4
(31.5)/4
(f'ci)/2
(31.5)/2
I.
II.
Compression
(31.5)
= 18.9 MPa
Tension
At mid-span
At support
= 1.4 MPa
= 2.8 MPa.
= 2.638 E4 MPa.
f'c
45 MPa
Ec
4700 x
I.
Sustained Compression
*topg top
II.
III.
*topg top
0.45 f'ci
0.45 x 45
0.45 x f'ci
0.45 x 28
= 12.6 MPa
0.62 x
(f'c)
0.62 x
0.6 x f'c
0.6 x 45
0.6 x f'ci
0.6 x 25
Tension
Final compression
= 20.25 MPa
= 27 MPa
= 15.0 MPa
24.0 kN/m3
b. Live load
Live Load
For Stair case
c. Wind load
The design of wind pressure shall be calculated on the basis of the following data as per ASCE/SEI
7-10 :-
=
=
=
41.67 m/s
C
1.15
d. Seismic load
The design of seismic load calculated as per UBC 97 :-
Zone
Soil Type
Importance factor
1.25
=
=
=
=
1.2
1.6
1.6
1.0
=
=
1.4
1.2
Dead Load
Live Load
Wind Load
Seismic Load
Service:
a. Stripping
b. Erection
Connections:
Beams are simply supported on top of column or corbel thus:
32mm is exposed from columns corbel to transfer horizontal shear force and steel plate @ top
of beam and column used as tie connection, (see detail below)
Additional reinforcement in top of column is added for column bearing as follows:
Provide 10mm columns ties at 100mm, for x = 500mm, from top & bottom.
Provide (4x4) (16 U Shape in both directions).
Steel Plate
PC Beam
32 mm Dowel
PC Column
Corbel
Basis of Design:
1. Design the precast concrete structure its components and connection in accordance with