You are on page 1of 2

Farnell Code

3943562

Current Transducer LA 100-P/SP13

IPN

100 A

For the electronic measurement of currents : DC, AC, pulsed...,


with a galvanic isolation between the primary circuit (high power)
and the secondary circuit (electronic circuit).

Electrical data
IPN
IP
RM

Primary nominal r.m.s. current


Primary current, measuring range
Measuring resistance
with 12 V
with 15 V

IS N
KN
VC
IC
Vd

@ 100 A max
@ 160 A max
@ 100 A max
@ 160 A max

Secondary nominal r.m.s. current


Conversion ratio
Supply voltage ( 5 %)
Current consumption
R.m.s. voltage for AC isolation test, 50 Hz, 1 mn

100
0 .. 160
RM min
RM
10
10
40
40

65
30
95
50

A
A

Closed loop (compensated) current

max

100
mA
1 : 1000
12 .. 15
V
10 (@15 V ) +IS mA
2.5
kV

Accuracy - Dynamic performance data


X

Accuracy @ IPN , TA = 25C

@ 15 V ( 5 %)
@ 12 .. 15 V ( 5 %)

Linearity

0.45
0.70
< 0.15
Typ

%
%
%
Max
0.2
0.3
0.5

Offset current @ IP = 0, TA = 25C


Residual current 1) @ IP = 0, after an overload of 3 x IPN
Thermal drift of IO
- 25C .. + 70C

0.1

tra
tr
di/dt
f

Reaction time @ 10 % of IPN


Response time 2) @ 90 % of IPN
di/dt accurately followed
Frequency bandwidth (- 1 dB)

< 500
<1
> 200
DC .. 200

mA
mA
mA
ns
s
A/s
kHz

General data
Ambient operating temperature
Ambient storage temperature
Secondary coil resistance @ TA = 70C
Mass
Standards 3)

transducer using the Hall effect

Printed circuit board mounting


Insulated plastic case recognized
according to UL 94-V0.

Special features
IP = 0 .. 160 A
K N = 1 : 1000
T A = - 25C .. + 70C.

Advantages

IO
IO M
IOT

TA
TS
RS
m

Features

Excellent accuracy
Very good linearity
Low temperature drift
Optimized response time
Wide frequency bandwidth
No insertion losses
High immunity to external
interference
Current overload capability.

Applications
AC variable speed drives and servo

- 25 .. + 70
- 40 .. + 85
25
18
EN 50178

C
C

motor drives

Static converters for DC motor drives


Battery supplied applications
Uninterruptible Power Supplies
(UPS)

Switched Mode Power Supplies


(SMPS)

Power supplies for welding


applications.
Notes :

1)
2)
3)

The result of the coercive field of the magnetic circuit


With a di/dt of 100 A/s
A list of corresponding tests is available
020222/0

LEM Components

w w w.lem.com

Dimensions LA 100-P/SP13 (in mm. 1 mm = 0.0394 inch)


Bottom view

Left view

Secondary terminals
Terminal + : supply voltage + 12 .. 15 V
Terminal - : supply voltage - 12 .. 15 V
Terminal M : measure

Connection
Standard 00
or N SP..

Year Week

Front view
Mechanical characteristics
General tolerance
Primary through-hole
Fastening & connection of secondary
Recommended PCB hole

Remarks
0.2 mm
12.7 x 7 mm
3 pins
0.63 x 0.56 mm
0.9 mm

IS is positive when IP flows in the direction of the arrow.


Temperature of the primary conductor should not exceed
100C.

Dynamic performances (di/dt and response time) are best


with a single bar completely filling the primary hole.

In order to achieve the best magnetic coupling, the primary


windings have to be wound over the top edge of the device.

LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.