You are on page 1of 3

CONFIDENTIONAL

Philips Lighting
P.O. Box 80020, 5600 JM Eindhoven, The Netherlands

Global Business Unit Hospitality

Upgrade instruction
For
xxHFL5870D/00
xxHFL5880D/10
to
MR4.5 release

Category:

Confidential

Status:

Final

Author:

Jan H W Nieuwlaat

Date:

2010-10-29

CONFIDENTIONAL

Introduction
This FW upgrade instruction is intended for installer as basis for FW upgrade of UHD system TV in standalone mode.
Instruction is valid for upgrading production FW version to MR4.5
Prod. FW
MR4.5
Remarks
SSB
0.25.1
0.35.0
Iboard
1.06.0
1.14.5
ST (MPEG4)
MPEG4_1.30.13.0
MPEG4_1.30.18.0
Tools needed: Green or Yellow setup remote control and
two USB sticks (avoid Kingston as this brand is known for
its problems during cloning)
Figure 1 RC2573

Step 1

Figure 2 22AV8573

Have USB drive 1 with correct FW available; empty stick with just 1 directory: upgrades
This directory should contain 2 files:
1. ssbfirmware.upg
2. iboardfirmware.bin
Master TV:
1
1. Upload new FW to TV (insert USB drive and press F button on green remote to start)
Pay attention to the following screens:

TV will automatically restart. DO NOT REMOVE the USB drive.

2.

TV will automatically restart. Remove the USB drive


Check with Recall button the FW version is correct

Line 03 = Iboard Firmware


Line 04 = SSB Firmware

Note that when using F button or Reset button several error messages will appear on screen of those items which are not included on the USB (e.g. Vsecure); No action

needed.
The attached material and the information contained therein are proprietary to Philips and are issued only under strict confidentiality arrangements. It
shall not be used, reproduced, copied in whole or in part, adapted, modified, or disseminated without a written license of Philips. It must be returned to
Philips upon its first request.

Upgrade instruction MR4.5 Generic

v1.04.docx

Copyright 2010 Koninklijke Philips Electronics N.V.

CONFIDENTIONAL

3.

Reset iboard NVM; press on green setup remote: 042420Menu

Press RIGHT and get next message STORING.

When STORING disappears press Menu to leave this Diagnostic menu.


Cold start TV (remove mains power).
4.

5.
6.

Set configuration:
Subtitles at startup = off
Specific predefined settings for hotel, like startup channel.
Set correct channel installation parameters.
Perform a Clean install: do a channel search for appropriate systems, hereafter a channel sort needs to be done. Ask
Philips HQ for assistance if needed.
Clone data to master USB drive 2

Step 2
Other TVs:
2
7. USB drive 1: Upload new FW (insert USB drive and press F button on green remote to start)
Same procedure as described at STEP1 #1, #2 and #3 .
1
8. USB drive 2: Clone master data (Press Reset button on green remote to start)
Pay attention to the ssb_nvm cloning part is OK, see OSD screen below:

After a restart the iboardnvm will be stored, showing this screen:

Note:
TV will restart automatically, in
between NVM uploading actions.
DO NOT REMOVE the USB drive
2

Note that when using F button or Reset button several error messages will appear on screen of those items which are not included on the USB (e.g. Vsecure); No action

needed.
The attached material and the information contained therein are proprietary to Philips and are issued only under strict confidentiality arrangements. It
shall not be used, reproduced, copied in whole or in part, adapted, modified, or disseminated without a written license of Philips. It must be returned to
Philips upon its first request.

Upgrade instruction MR4.5 Generic

v1.04.docx

Copyright 2010 Koninklijke Philips Electronics N.V.

You might also like