You are on page 1of 2

[RE-wrenches] SB 240 - No Neutral Sense Conductor

1 of 2

http://lists.re-wrenches.org/pipermail/re-wrenches-re-wrenches.or...

[RE-wrenches] SB 240 - No Neutral Sense


Conductor
Bill Brooks billbrooks7 at yahoo.com
Thu Dec 19 08:44:19 PST 2013
Previous message: [RE-wrenches] SB 240 - No Neutral Sense Conductor
Next message: [RE-wrenches] Any familiarity with Dynapro batteries?
Messages sorted by: [ date ] [ thread ] [ subject ] [ author ]
Mark,

There are many inverters that do not have a neutral-just not many
single-phase inverters. Since all inverters must have at least an equipment
ground, the phases can be compared with ground. The testing standard covers
what is required. If neutral-ground bond is lost, it will show up in a bad
voltage phase-to-ground.

Since utility-interactive (U-I) inverters just inject current when the


utility voltage is in proper range, our inverters do not produce a separate
voltage. The only problems that our inverters can cause is a slightly raised
voltage due to current flow at the point of connection. Also, a much less
likely but current concern in Hawaii is temporary overvoltage. As the
utility voltage goes to zero in an outage, a U-I inverter must quickly clamp
its current or the voltage at the inverter terminals (and potentially the
house service) could momentarily go above nominal voltage. Generally, this
is not a problem since an inverter that does not act quickly enough will
damage itself.

Bill.

Bill Brooks, PE
Principal
Brooks Engineering
3949 Joslin Lane
Vacaville, CA 95688
707-332-0761 (office and mobile)
bill at brooksolar.com (email)
www.brooksolar.com (web)

2015-11-07 7:16 AM

[RE-wrenches] SB 240 - No Neutral Sense Conductor

2 of 2

http://lists.re-wrenches.org/pipermail/re-wrenches-re-wrenches.or...

From: re-wrenches-bounces at lists.re-wrenches.org


[mailto:re-wrenches-bounces at lists.re-wrenches.org] On Behalf Of Mark Frye
Sent: Thursday, December 19, 2013 8:10 AM
To: RE-wrenches
Subject: [RE-wrenches] SB 240 - No Neutral Sense Conductor

Folks,
I was looking at the SMA micro inverter and notice only connections for L1,
L2 and earth. I thought all grid tied inverters needed a neutral sense
conductor to monitor for phase loss.
Any ideas?
Mark Frye

--This email is free from viruses and malware because avast! Antivirus protection is active.
http://www.avast.com
-------------- next part -------------An HTML attachment was scrubbed...
URL: <http://lists.re-wrenches.org/pipermail/re-wrenches-re-wrenches.org/attachments
/20131219/f6c3dffc/attachment-0002.htm>

Previous message: [RE-wrenches] SB 240 - No Neutral Sense Conductor


Next message: [RE-wrenches] Any familiarity with Dynapro batteries?
Messages sorted by: [ date ] [ thread ] [ subject ] [ author ]
More information about the RE-wrenches mailing list

2015-11-07 7:16 AM

You might also like