Professional Documents
Culture Documents
High resistance to thermal cracking and decomposition resulting in freedom from sludge and coke deposits
and minimum interference with heat transfer capability
Excellent thermal properties giving high heat transfer rates and improved operating efficiency
Long trouble free service life
Easy starting of cold systems
Applications
Mobiltherm 605 heat transfer oil is recommended for use in closed, cold-oil sealed, indirect heating and cooling
systems in all kinds of industrial processes operating at bulk oil temperatures up to a maximum of 320C and
at atmospheric pressure. Mobiltherm 605 can be used in installations where the bulk oil temperature is as high
as 320C and where minimum shutdown temperatures are not below about -12C. If the oil is used above its
recommended maximum temperatures, vapour lock may result unless the system is designed to operate at the
higher temperature by pressurizing with an inert gas such as nitrogen. However, at higher temperatures, fluid
life will be shortened because the rate of thermal degradation increases markedly as temperatures rise above
the recommended limit. In well-designed systems the temperature of the oil film surrounding the heating element
should be about 15C to 30C above the bulk oil temperature. If higher than this, the service life of the oil may
be shortened and sludge and coke may be deposited which would interfere with the heat transfer rates. Mobiltherm
605 should not be mixed with conventional oils since this may impair the excellent thermal and oxidation stability
of the Mobiltherm 605 oil which may cause a change in other properties and complicate the interpretation of
analyses made to determine the oil's useful life. As with other mineral oils, Mobiltherm 605 heat transfer oil
should be used only in systems with forced circulation. Systems that depend on convection for circulation of
the heat transfer medium do not provide a rapid enough flow to prevent local overheating and rapid deterioration
of the oil. Further, the oil is not recommended for use in open systems where hot oil is exposed directly to the
air. If it sprays or escapes from leakage points, hot Mobiltherm 605 may spontaneously ignite.
1 of 2
01-2006
Typical Properties
Mobiltherm 605
CMCS Code
Appearance
KV @ 40C
KV @ 100C
Viscosity Index
Flash Point COC
Flash Point PMCC
Fire Point
Pour Point
Neutralization Number
GC SimDis Carbon Residue
Conradson Carbon Residue
Saturates
Aniline Point
Noak Volatility
RBOT
Vapor Pressure @ 204.5C
Vapor Pressure @ 260C
Vapor Pressure @ 315.5C
Thermal Conductivity @ 37.8C
Thermal Conductivity @ 148.9C
Thermal Conductivity @ 260C
Specific Heat @ 204.4C
Specific Heat @ 260C
Specific Heat @ 315.5C
Distillation GC, IBP
GC SimDis 10% Recovered
GC SimDis 30% Recovered
GC SimDis 50% Recovered
Sulfur
Test Method
Visual
ASTM D 445
ASTM D 445
ASTM D 2270
ASTM D 92
ASTM D 92
ASTM D 92
ASTM D 97
ASTM D 974
ASTM D 2887
ASTM D 189
ASTM D 2007
ASTM D 611
ASTM D 5800
ASTM D 2272
ASTM D 2879
ASTM D 2879
ASTM D 2879
ASTM D 2717
ASTM D 2717
ASTM D 2717
ASTM D 2766
ASTM D 2766
ASTM D 2766
ASTM D 2887
ASTM D 2887
ASTM D 2887
ASTM D 2887
ASTM D 2622
Unit
mm2/s
mm2/s
none
C
C
C
C
mg KOH/g
%
wt%
wt%
C
wt%
min
torr
torr
torr
cal/scmC
cal/scmC
cal/scmC
kJ/KgK
kJ/KgK
kJ/KgK
C
C
C
C
wt%
970767
Bright and Clear
32
5.2
95
200
180
220
-6
0.05
15
0.05
68
120
20
30
1.7(max)
14(max)
70(max)
3.1 E-04
2.9 E-04
2.7E-04
2.7
2.9
3.1
315
385
415
430
0.75(max)