You are on page 1of 25

SAMPLE BOQ

BILL No. 10 - CONSTRUCTION OF OFFICE AND STORES

Item SLS 573


Description
No.
Code
No.
D-EXCAVATION & EARTH WORK

Uni
t

Site Preparation
1

D.1.1.1

Clearing site vegitation including bushes,


shurbs under growth hedges and trees
and stumps not exceeding 500 mm girths
and carting away debries from site.

m2

Excavation
Rate to include for preparation of
surface and compacting.
2

D.2.1.1

Excavation top soil


average 150 mm deep.

D.2.4.1

Excavating pits in any


than rock with depth
1.00m.

D.2.5.1

Excavating trenches width exceeding 300 m3


mm and depth not exceeding 1.00 m
commencing from bottom of top soil layer.

D.4.0.1

Extra over item No. 3-4 for excavation in m3


rock.

for

preservation m2

material other m3
not exceeding

Earth work Support


6

D.7.1.1

Earth work Support total depth not m2


exceeding 1.00 m and distance between
opposing faces not exceeding 2.00 m
Disposal

D.8.1&
2

Disposal of surface and ground water

D.8.3.2. Disposal of excavated top soil on site spoil m3


heaps
average
1.0
maway
from
1
excavations

10 - 1

ite
m

Qty

Rate
SL. Rs.

Amount
SL. Rs.

Item SLS 573


Description
Uni
No.
t
Code
No.
Total of page No carried summary in
page No

10 - 2

Qty

Rate
SL. Rs.

Amount
SL. Rs.

Item SLS 573


Description
No.
Code
No.
9
Disposal of excavated material off site.
D.8.3.1

Uni
t
m3

Filling
10

D.9.3.1. Filling to make up levels with excavated m3


material on site laid in 150 mm layer well
1
rammed watered and consolidated.

11

D.9.3.1. Filling to make up levels 350 mm average m3


thickness with hard earth obtained off site
2
laid in 150 mm thk layers well rammed
watered and consolidated.
F1 - CONCRETE WORK
Insitu concrete Gr. 10

12

F1.2.1.1 In foundation screed 75 mm thk for m2


column bases poured into ground.

13

F1.2.5.1 In foundation strip mass poured into m3


ground.
Reinforced concrete
otherwise stated.

Gr.20

unless

14

F1.2.2.2 In Column Base

m3

15

F1.10.1. In columns with sectional area


exceeding 0.1 m2up to ground level
1

not m3

16

F1.10.1. In columns with sectional area


exceeding 0.1 m2above ground level
1

not m3

17

F1.3.1.2 In beds and slabs on ground thickness not m3


exceeding 150mm.

18

F1.12.1. In beam on rubble wall sectional area not m3


exceeding 0.1 m2 isolated
1

19

F1.14

In 225 x 150mm lintels (24 nr).

Total of page No
page No

carried summary in

10 - 3

m3

Qty

Rate
SL. Rs.

Amount
SL. Rs.

Item SLS 573


Description
No.
Code
No.
F2- FORM WORK

Uni
t

Wrought
Suitable material shall be used for wrought
formwork, so that surface shall have very neat
and smooth finish after removal to the approval.
20

F2.13.1. To sides of beam on rubble wall attached m


square
1.

21

F2.14.1.
1
F2.12.2.
1

22
23

To sides & soffits of Lintols attached m2


rectangular
To sides of Columns attached and isolated m2
rectangular up to ground level.

F2.12.2. To sides of Columns attached and isolated


rectangular above ground level.
1

m2

F3 - REINFORCEMENT IN INSITU
CONCRETE
Tor/Mild steel rod reinforcement cut to lengths,
bent to shape, placed in position and tied with GI
wire
Mild Steel
24

F3.1.1.2 Bar diameter not exceeding 10 mm in ground beams

25

F3.1.1.6 Bar diameter not exceeding 10 mm in columns

Tor Steel
26

F3.2.2.1 Bar diameter 10-16mm in column bases.

27

F3.2.2.2 Bar diameter 10-16 mm in ground beams.

28

F3.2.1.3 Bar diameter 10-16 mm in ground slab.

29

F3.2.2.6 Bar diameter 10-16mm in columns.

30

F3.2.2.7 Bar diameter 10-16mm in lintols.

10 - 4

Qty

Rate
SL. Rs.

Amount
SL. Rs.

Item SLS 573


Description
Uni
No.
t
Code
No.
Total of page No carried summary in
page No

10 - 5

Qty

Rate
SL. Rs.

Amount
SL. Rs.

Item SLS 573


Description
No.
Code
No.
F4 - PRECAST CONCRETE
31

Uni
t

F4.17.1 Pre cast concrete 600 x 300 mm drain nr


cover slabs
G-MASONRY WORK
G1 - Brick work

32

G1.1.1.
1

33

G1.1.1.
1

34

G1.8.1

35

G1.8.1

36

G2.1.1.
1.1

37

G2.1.1.
1

225 mm thick vertical solid common


bricks built in cement mortar 1:5 in
English bond.
115 mm thick vertical solid common
bricks built in cement mortar 1:5 in
strecher bond.
1450 x 300 x 150 mm size door step
(Including 1:3 16 mm thk finished smooth
neat colour cement floating) complete as
shown in detail on drawing.
1200 x 300 x 150 mm size door step
(Including 1:3 16 mm thk finished smooth
neat colour cement floating) complete as
shown in detail on drawing.
G2 - Stone Work

m2
m2
nr

nr

225 mm thickness vertical rubble stone m2


work walls built in cement sand mortar
1:6
350 mm thick vertical rubble stone work m2
walls built in cement sand mortar 1:6
H- WATER PROOFING

38

m
H.2.1.1 Damp proofing course
width not
exceeding 300 mm horizontal 12 mm
thickness cement sand 1:3 rendering
treated with two coats cold tar on top.

39

H.2.2.1 Damp proofing course width exceeding m2


300 mm horizontal 12 mm thickness
cement sand 1:3 rendering treated with
two coats cold tar on top.

10 - 6

Qty

Rate
SL. Rs.

Amount
SL. Rs.

Item SLS 573


Description
Uni
No.
t
Code
No.
Total of page No carried summary in
page No

10 - 7

Qty

Rate
SL. Rs.

Amount
SL. Rs.

Item SLS 573


Description
No.
Code
No.
K - METAL WORK

40

K.9.1

Uni
t

All material supplied, fabricated and fixed


in position complete as shown in detail on
drawing and as specified. Provision shall
be made for breaking walls / concrete
floors whenever necessary and making
Steel
collapsible
good as
directed. door type D8 2750 x nr
2500 mm complete as shown in detail on
drawing and as specified.

L-WOOD WORK
Wood preservative shall be applied to
timber work before fixing.Complete as
shown in drawing & as directed.
L1 - Carpentry
41

L1.3.1

Ceiling framing 50 x 100 mm joists

42

L1.3.1

Ceiling framing 50 x 50 mm joists

43

L1.3.5

44

Ceiling framing 25 x 50 mm connecting m


piece
m
L1.4.7.1 Roof Framing 100 x75 mm wall plate

45

L1.4.4.1 Roof Framing 100 x75 mm ridge plate

46

L1.4.3.1 Roof Framing 75 x125 mm purlin

47

L1.4.1.1 Roof Framing 75 x125 mm post

48

L1.4.2.1 Roof Framing 50 x100 mm rafter

49

L1.4.6.1 Roof Framing 50 x50 mm reeper

Total of page No
page No

carried summary in

10 - 8

Qty

Rate
SL. Rs.

Amount
SL. Rs.

Item SLS 573


No.
Code
No.
L2 - Joinery

Description

Uni
t

50

L2.11.2. Valance board width not exceeding 300 m


mm 225 x 20 mm cross section fix to feet
1
of rafters with brass screws

51

L2.18.1. Door type D1 ordinary 1200 x 2500 mm nr


overall consisting of 100 x 75 mm frame
1
and 32 mm thickness 1074 x2062 mm size
door sash with 300 mm high slats on
above as shown in detail on drawing fix
complete.Area 3.00 m2

52

L2.18.1. Door type D2 ordinary 1000 x 2500 mm nr


overall consisting of 100 x 75 mm frame
1
and 32 mm thickness 824 x2062 mm size
door sash with 300 mm high slats on
above as shown in detail on drawing fix
complete.Area 5.00 m2

53

L2.18.1. Battened Door type D3 ordinary 1800 x nr


2025 mm overall consisting of 100 x 75
1
mm frame and 32 mm thk 1724 x1887 mm
size door sash fix with 50 x 25 mm
bracings as shown in detail on drawing fix
complete.Area 3.75 m2

54

L2.18.1. Door type D4 ordinary 820 x 2125 mm nr


overall consisting of 100 x 75 mm frame
1
and 32 mm thickness 694 x2062 mm size
marine plywood door sash fix with as
shown
in
detail
on
drawing
fix
complete.Area 3.49 m2
L2.18.1. Door type D5 ordinary 820 x 2500 mm nr
overall consisting of 100 x 75 mm frame
1
and 32 mm thickness 674 x2062 mm size
marine plywood
door sash fix with
300mm high slats on above as shown in
detail on drawing fix complete.Area 4.1 m2

55

Total of page No
page No

carried summary in

10 - 9

Qty

Rate
SL. Rs.

Amount
SL. Rs.

Item SLS 573


Description
Uni
No.
t
Code
No.
56 L2.18.1.
Door type D6 ordinary 1000 x 2125 mm nr
overall consisting of 100 x 75 mm frame
1
and 32 mm thickness 874 x 2062 mm size
plywood door sash fix with as shown in
detail on drawing fix complete.Area 2.13
m2
57

L2.18.1. Door type D7 flush panel ordinary 600 x nr


2125 mm overall consisting of 100 x 75
1
mm frame and 32 mm thickness 474 x
2062 mm size door sash fix with as shown
in detail on drawing fix complete.Area
1.28 m2

58

L2.19.1. Window type W1 ordinary 2475 x 1725 nr


mm overall with 300 mm high slats on top
1
consisting of 100 x 75 mm frame and 28
mm thickness glazed window sashes four
numbers, side hung casement type as
shown
in
detail
on
drawing
fix
complete.Area 4.27 m2

59

L2.19.1. Window type W2 ordinary 1275 x 1725 nr


mm overall with 300 mm high slats on top
1
consisting of 100 x 75 mm frame and 28
mm thickness glazed window sashes two
numbers side hung casement type as
shown
in
detail
on
drawing
fix
complete.Area 11.00 m2

60

L2.20.1. Fanlight center pivote type F1 475 x nr


525mm overall with 100 x 75 mm frame
1
28 mm thk glazed fanlight sash as shown
in detail on drawing fix complete.Area 0.5
m2

61

L2.20.1. Fixed glass type FG 450 x 300 mm 100 x nr


75 mm frame and fixed glass as shown in
1
detail on drawing Area 0.54 m2

Total of page No
page No

carried summary in

10 - 10

Qty

Rate
SL. Rs.

Amount
SL. Rs.

Item SLS 573


Description
Uni
No.
t
Code
No.
62 L2.20.1.
G1 type 1500 x 1200 mm size with 100 nr
x75 mm frame and fixed 1350 x 1050 mm
1
size 50 x50 mm square iron mesh as
shown in detail on drawing complete.
Area 3.6 m2
L3 - Ironmongery
Door furniture
63

L3.1.1.1 75 x 125 mm butt hinges fix to timber

nr

64

L3.1.3.1 Mortise lock fix to timber

nr

65

L3.1.4.1 Bird lock fix to timber

nr

66

L3.1.2.1 Barrel bolt 150 mm long fix to timber

nr

67

L3.1.10. Pull rings 25 mm diameter fix to timber


1

nr

68

L3.1.11. Door handle 150 mm long fix to timber


1

nr

Window furniture
69

L3.2.1.1 75 x 100 mm hinges fix to timber

nr

70

L3.2.3.1 Casement fastner fix to timber

nr

71

L3.2.5.1 Casement stay fix to timber

nr

72

L3.2.6.1 Pull rings 25 mmdia. fix to timber.

nr

Total of page No
page No

carried summary in

10 - 11

Qty

Rate
SL. Rs.

Amount
SL. Rs.

Item SLS 573


Description
Uni
No.
t
Code
No.
Supplying and fixing in position
complete as shown in detail on
drawing and as directed.
73

P.10.1.1 Half round clay tiles lay over asbestos m2


roof covering
.2

74

P.14.

75

P.31.2.1 Profiled sheet covering asbestos cement m2


sheets fix to frame work (m.s) with and
including GI J bolts and nuts

76

P.36.1.1 Ridging with 1050 mm long asbestos m


adjustable ridges horizontal fix to frame.

77

P.43.1.1 Square upvc gutter with solvent cement m


joints fixed to facia board on pvc brackets
.1
@ 450 mm centers with brass screws.

78

P.44.1.1 Extra over for gutter box


.1
P.44.1.1 Extra over for miter joiner
.1
P.45.1.1 Down pipe straight upvc 90 mm diameter
with solvent cement joint including pvc
straps @ 1000 mm centers fix to wall with
25 mm clearance.
P.46.1.1 Extra over upvc 90 mm diameter down
pipes for sawn necks
.1

79
80

81

16 BWG galvanized iron sheet valley m


gutter 900 mm girth overall once bent
with end caps not less than 225 mm with
including 38 mm tongued and grooved
planks laid to slope and profile on timber
members

10 - 12

nr
nr
m

nr

Qty

Rate
SL. Rs.

Amount
SL. Rs.

Item SLS 573


Description
Uni
No.
t
Code
No.
Total of page No carried summary in
page No

10 - 13

Qty

Rate
SL. Rs.

Amount
SL. Rs.

Item SLS 573


Description
No.
Code
No.
Q
PLUMBING
/
INSTALLATION

Uni
t
SANITARY

Pvc pipe Type 1000


PVC pipes (type 1000) specials and fittings supplied,
laid and jointed or fixed complete to walls with
plated MS hooks/PVC brackets or buried in walls as
required upto 2.0 m beyond outer walls and all PVC
pipes shall conform to ISO standards
82

Q.1.1.6. 20 mm dia. Pipe


1

83

Q.1.1.6. 25 mm dia. pipe


1

84

85

Q.1.1.6. 40 mm dia. Pipe


1
Q.2.1.1 Extra over for 20 mm dia. Elbows

nr

86

Q.2.1.1

Extra over for 25 mm dia. Elbows

nr

87

Q.2.1.1

Extra over for 40 mm dia. Elbows

nr

88

Q.2.1.2

Extra over for 25 mm dia.90 degree bends

nr

89

Q.2.1.2

Extra over for 40 mm dia.90 degree bends

nr

90

Q.2.1.6

Extra over for 25 x 20 mm dia.reducing socket

nr

91

Q.2.1.6

Extra over for 40 x 25 mm dia.reducing socket

nr

Waste water Installation


Pvc pipe type 1000

94

Q.1.1.3. 50 mm dia. pipe in walls


1
Q.1.1.2. 63 mm dia. Pipe in trenches
1
Q.2.1.2 Extra over for 50 mm dia.90 degree bends

nr

95

Q.2.1.2

Extra over for 60 mm dia.90 degree bends

nr

92
93

10 - 14

m
m

Qty

Rate
SL. Rs.

Amount
SL. Rs.

Item SLS 573


Description
Uni
No.
t
Code
No.
Total of page No carried summary in
page No

10 - 15

Qty

Rate
SL. Rs.

Amount
SL. Rs.

Item SLS 573


Description
No.
Code
No.
Extra over for 50 mm dia.Elbows
96 Q.2.1.2
97

Q.2.1.2

Uni
t
nr

Extra over for 60 mm dia.Elbows

nr

Gullies
98

Q.3.1.1

Supply and fix in position 150x150x75 mm dia. PVC nr


open top trapped back inlet gulley with approved
plastic grating including Jointing to pipe
All fixtures shall be supplied and fixed complete
including effecting connection to water main and
disposal connection as required .

All sanitary fittings shall be of approved colour


unless other wise stated.
99

Q.5.1.1

100 Q.5.1.1

Low level water closet suite with 9 litre nr


cistern, overflow connection, brackets,
seat cover and other necessary fittings
complete.
Ceramic wash basin
pedestal type nr
complete with bottle trap chained plug
and chromim plated waste top and tap.

101 Q.5.1.1

Ceramic corner wash basin with tap nr


,waste plug and chain complete

102 Q.5.1.1

Approved quality ceramic squatting pan nr


complete with 'P' trap, 9 litres capacity
high level cistern, flush pipe, overflow
connection, CI brackets and other
necessary fittings complete.
Furnish and fix bath room accessories
with necessary fittings

103 Q.5.1.1

600 x 700 mm mirror of approved quality nr


complete with fittings

104 Q.5.1.1

Chromium plated Towel Rail

nr

105 Q.5.1.1

Hand bidet with angle valves

nr

Total of page No
page No

carried summary in

10 - 16

Qty

Rate
SL. Rs.

Amount
SL. Rs.

Item SLS 573


Description
No.
Code
No.
106 Q.5.1.1
Chromium plated paper roll holder

Uni
t
nr

107 Q.5.1.1

150 x 150 mm ceramic soap tray

nr

108 Q.5.1.1

100 x 100 mm robe hook

nr

109 Q.5.1.1

600 mm long towel rail with ceramic brackets.

nr

110 Q.5.1.1

100 mm chromium plated wall mounted adjustable nr


shower rose complete.

111 Q.5.1.1

Chromium plated 12 mm dia. bib tap including PVC nr


pipes and fittings.
Cocks valves etc
(Rate to include for effecting connection to main)

112 Q.14.1.1 40 mm dia. Brass stop valve

nr

S - ELECTRICAL INSTALLATION
Note: All conduit pipes/ cables are to be
concealed in walls and ceiling. Wiring to
be completed upto M.C board. Contractor
to carry necessary testing.
All materials supplied, installed or
fixed complete as directed. Rate to
include for all PVC wiring involved as
specified of approved make complete
to working order. All fixtures shall be
of approved quality and makes to the
satisfaction of the engineer and as
specified in the specification
113 S.1.1.2

Single-phase 30 amp main circuit breaker nr


and 30 amp RCCB with 6 way miniature
circuit breakers of ratings as required and
breakers incorporated in one plastic box
having transparent front lid. Rate to
include for suitable buss bar.

114 S.11.2.1 Main electric cables (7/044) to Main m


Distribution Board

10 - 17

Qty

Rate
SL. Rs.

Amount
SL. Rs.

Item SLS 573


Description
Uni
No.
t
Code
No.
Total of page No carried summary in
page No

10 - 18

Qty

Rate
SL. Rs.

Amount
SL. Rs.

Item SLS 573


Description
Uni
No.
t
Code
No.
115 S.22.1.1
Final circuits point wiring for socket nr
outlets
116 S.22.1.3 Final circuit point wiring for lighting nr
switches
117 S.24.1
One way one gang switch
nr
118 S.24.1

One way two gang switch

nr

119 S.25.1.1 Fluorescent single lamp fitting (40 w)

nr

120 S.25.1.1 Fluorescent single lamp fitting (20 w)

nr

121 S.23.1

5 amp switched socket outlet flushed type

nr

122 S.23.1

15 amp switched socket outlet flushed nr


type
Earth electrode complete with 50 mm dia. nr
2.00 m long GI pipe driven in to ground
for connecting frame work continuity
conductor in order to obtain satisfactory
earth resistance reading as required by
the CEB.

123 S. 27

T-FLOOR/WALL FINISHES
T1 - Floor finishes
124 T1.1.1.1 Floor finishes in cement sand 1:3 level m2
and to slopes not exceeding 15 0 to
.
horizontal 12 mm thickness finished
smooth with neat colour cement floating.
125 T1.1.1.1 Floor finishes cement sand 1:3 level and m2
to slopes not exceeding 15 0 to horizontal
.
12 mm thickness finished rough to receive
floor tiles.

Total of page No
page No

carried summary in

10 - 19

Qty

Rate
SL. Rs.

Amount
SL. Rs.

Item SLS 573


Description
Uni
No.
t
Code
No.
126 T1.9.1.1
Floor finishes ceramic floor tiles of m2
approved colour and quality and matt
.
finish level and to slopes not exceeding 15
0
from horizontal with cement slury and
joints finished with matching grout.
127 T1.9.1.1 Floor finishes ceramic floor tiles of m2
approved colour and quality and Non skid
.
finish level and to slopes not exceeding 15
0
from horizontal with cement slury and
joints finished with matching grout.
128 T1.9.9.1 Floor finishes cement sand 1:3 16 mm thk m
ceramic tile skirting finished with cement
.1
slurry and joints finished with matching
grout.
129 T1.10.1. Floor finishes cement sand 1:3 16 mm thk m
skirting finished with a 'v' cut at the
1.
junction of wall and skirting fiished
smooth with neat colour cement floating .
T2-Wall finishes

130 T2.2.1.1 Walls finishes width exceeding 300 mm m2


cement mortar 1:3 plaster to plinth 16
.1
mm thickness finished smooth with neat
colour cement floating
131 T2.1.2.1 Walls finishes width exceeding 300 mm m2
cement : lime : sand 1:1:5 plaster to
.1
internal faces of walls 12 mm thickness
finishes
smooth
including
attached
columns & column projections plastering.
132 T2.1.2.1 Walls finishes width exceeding 300 mm m2
cement : lime : sand 1:1:5 plaster to
.1
external faces of walls 16 mm thickness
finished semi rough.

10 - 20

Qty

Rate
SL. Rs.

Amount
SL. Rs.

Item SLS 573


Description
Uni
No.
t
Code
No.
Total of page No carried summary in
page No

10 - 21

Qty

Rate
SL. Rs.

Amount
SL. Rs.

Item SLS 573


Description
Uni
No.
t
Code
No.
133 T2.1.1.1
Walls finishes width not exceeding 300 m
mm cement : lime : sand 1:1:5 plaster 16
.1
mm thickness to external reveals and
jambs finished semi rough with wood
float.
134 T2.1.1.1 Walls finishes width not exceeding 300 m
mm cement : lime : sand 1:1:5 plaster 12
.1
mm thickness to internal reveals and
jambs finished smooth.
135 T2.13.1. Wall finishes12 mm thk cement sand 1:3 m2
width exceeding 300 mm to vertical laid
1
ceramic wall tiles with cement slurry and
joints finished with matching grout for
toilet & bath
136 T2.14.2. Asbestos sheet ceiling fixed to timber m2
frame work (m.s.)
2

V-PAINTING
137 V.1.1.1. Painting plastered work general surface m
girth not exceeding 300 mm plain
1
surfaces with one coat primer and two
coats emulsion paint of approved colour
and quality internally
138 V.1.1.1. Painting plastered work general surface m2
girth exceeding 300 mm plain surfaces
1
with one coat primer and two coats
emulsion paint of approved colour and
quality internally
139 V.1.1.1. Painting plastered work general surface m
girth not exceeding 300 mm plain
1
surfaces with one coat primer and two
coats weathershield paint of approved
colour and quality externally

10 - 22

Qty

Rate
SL. Rs.

Amount
SL. Rs.

Item SLS 573


Description
Uni
No.
t
Code
No.
Total of page No carried summary in
page No

10 - 23

Qty

Rate
SL. Rs.

Amount
SL. Rs.

Item SLS 573


Description
Uni
No.
t
Code
No.
140 V.1.1.1.
Painting plastered work general surface m2
girth exceeding 300 mm plain surfaces
1
with one coat primer and two coats
weathershield paint of approved colour
and quality externally
141 V.4.3.2. Painting wood work glazed windows girth m2
exceeding 300 mm plain surfaces with
1
one coat sealer and two coats enamel
paint of approved colour and quality
142 V.4.3.2. Painting wood work glazed windows girth m2
exceeding 300 mm irregular surfaces with
2
one coat sealer and two coats enamel
paint of approved colour and quality

143 V.4.1.2. Painting wood work general surfaces girth m2


exceeding 300 mm plain surfaces with
1
one coat sealer and two coats enamel
paint of approved colour and quality
144 V.4.2.2. Painting wood work facia board and the m
like isolated surfaces girth not exceeding
1
300 mm plain surfaces with one coat
sealer and two coats paint of approved
colour and quality
145 V.4.1.2. Painting wood work general surfaces girth m2
exceeding 300 mm irregular surfaces
2
with one coat sealer and two coats enamel
paint of approved colour and quality

W - DRAINAGE SYSTEMS
146 W.10.1. 110 mm dia.pipes in trenches
1

147 W.11.1. Extra over for 110 mm dia. Elbows


5

nr

148 W.11.1. Extra over for 110 mm dia. Bends


1

nr

Total of page carried summary in page


No

10 - 24

Qty

Rate
SL. Rs.

Amount
SL. Rs.

Item SLS 573


Description
Uni
No.
t
Code
No.
Construction of 450 x 450 x 550 mm internal size nr
149 W.13.1.
Man hole
1

150 W.13.1. Construction of 600 x 600 x 600 mm internal size nr


Man hole
1

151 W.17.1. Construction of Type 'B' (9 to 15 persons)


nr
Septic tank and Soakage pits as per Drawing No WT
1
222/01.

MISCELLONEOUS WORK

152 X 12

600 mm wide 75 mm thk brick pavement m


and internal size 200 x200 mm,100 mm
thk brick wall drain complete as shown in
detail on drawing W994/07/01(Including
necessary excavation and 12 mm thk 1:3
cement sand rendering)

Total of page carried summary in page


No

10 - 25

Qty

Rate
SL. Rs.

Amount
SL. Rs.

You might also like