You are on page 1of 4

OTDR report

Job ID
Contractor
Customer
Test date

:
:
:
:

alfa sri soedewi


PT.MITRA MEDIA SELARAS
PT.ICON+
2/3/2016 (8:24:32 PM GMT+7:00)

Fiber ID
Location A
Cable mfr.
Subset ID

:
:
:
:

001
alfa sri soedewi
FIBER HOME 6 CORE
blue

Span loss
Span length
Average loss

: 0.375 dB
: 0.2499 km
: 1.500 dB/km

Job info

Reason
Operator A
Operator B
File

Cable info

Cable ID
Location B
Type
Color ID

Link measurements

Avg. splice loss


Max. splice loss
Span ORL

:
:
:
:

FIBER OPTIC
RIZA
NASRUN
alfa sri dewi to jb tab 01.trc

:
:
:
:

FIG 8
JB TAP
SINGLE MODE
blue

: --: --: 26.85 dB

OTDR trace
dB

30.00

25.00

20.00

1
15.00

2
10.00

5.00

0.00

100

Signature : _________________________
EXFO Inc.

200

300

400

500

600

Date : 2/28/2016
Page 1 / 4

OTDR report
Events table
No.

Loc.
(km)

0.0000
0.0000
0.0021

0.2499

Event type
Merged Event
Fiber Section (0.2499 km)
Reflective Event

A
a
A to B distance
3-pt. reflectance
4-pt. Ev. loss

:
:
:
:
:

0.1200 km, 8.603 dB


0.0600 km, 8.756 dB
0.0600 km, -0.106 dB
-77.8 dB
0.246 dB

Wavelength
Filename
Hardware
Serial number
Software
Range
IOR
RBS

:
:
:
:
:
:
:
:

1550 nm (SM-9m)
alfa sri dewi to jb tab 01.trc
MAX-715B-M1-EI
735666
N/A
0.6500 km
1.468325
-81.87

Signature : _________________________
EXFO Inc.

Loss
(dB)

Refl.
(dB)

---

-27.1
-40.8
-27.1

0.375
---

Marker info

B
b
A to B ORL
A to B LSA att.

Test and cable setup

Acq. time
Pulse width
Helix factor
Splice loss threshold
Reflectance threshold
End-of-fiber threshold

Att.
(dB/km)

Cumul.
(dB)
0.000

1.500
-41.4

:
:
:
:

0.1799 km, 8.709 dB


0.2399 km, 8.666 dB
54.21 dB
2.236 dB/km

:
:
:
:
:
:

15 s
10 ns
0.00 %
0.020 dB
-72.0 dB
5.000 dB

0.375
0.375

Date : 2/28/2016
Page 2 / 4

OTDR report
Job ID
Contractor
Customer
Test date

:
:
:
:

alfa sri soedewi


PT.MITRA MEDIA SELARAS
PT.ICON+
2/3/2016 (8:24:47 PM GMT+7:00)

Fiber ID
Location A
Cable mfr.
Subset ID

:
:
:
:

001
alfa sri soedewi
FIBER HOME 6 CORE
blue

Span loss
Span length
Average loss

: 0.748 dB
: 0.2501 km
: 2.990 dB/km

Job info

Reason
Operator A
Operator B
File

Cable info

Cable ID
Location B
Type
Color ID

Link measurements

Avg. splice loss


Max. splice loss
Span ORL

:
:
:
:

FIBER OPTIC
RIZA
NASRUN
alfa sri dewi to jb tab 01.trc

:
:
:
:

FIG 8
JB TAP
SINGLE MODE
blue

: 0.362 dB
: 0.362 dB
: ---

OTDR trace
dB

30.00

1
25.00

20.00

15.00

10.00

5.00

0.00

100

Signature : _________________________
EXFO Inc.

200

300

400

500

600

Date : 2/28/2016
Page 3 / 4

OTDR report
Events table
No.

Loc.
(km)

0.0000
0.0000
0.0019
0.0084

0.0651

0.2501

Event type
Merged Event

Loss
(dB)

Refl.
(dB)

---

-53.4

Att.
(dB/km)

Cumul.
(dB)
0.000

-53.4
Fiber Section (0.0651 km)
Non-Reflective Event
Fiber Section (0.1850 km)
Reflective Event

A
a
A to B distance
3-pt. reflectance
4-pt. Ev. loss

:
:
:
:
:

0.1200 km, 28.245 dB


0.0600 km, 28.575 dB
0.0600 km, 0.207 dB
-77.9 dB
0.441 dB

Wavelength
Filename
Hardware
Serial number
Software
Range
IOR
RBS

:
:
:
:
:
:
:
:

1310 nm (SM-9m)
alfa sri dewi to jb tab 01.trc
MAX-715B-M1-EI
735666
N/A
0.6500 km
1.467700
-79.45

Signature : _________________________
EXFO Inc.

0.071
0.362
0.314
---

Marker info

B
b
A to B ORL
A to B LSA att.

Test and cable setup

Acq. time
Pulse width
Helix factor
Splice loss threshold
Reflectance threshold
End-of-fiber threshold

1.095
1.700
-61.6

:
:
:
:

0.1799 km, 28.038 dB


0.2399 km, 27.941 dB
52.01 dB
3.261 dB/km

:
:
:
:
:
:

9s
10 ns
0.00 %
0.020 dB
-72.0 dB
5.000 dB

0.071
0.433
0.748
0.748

Date : 2/28/2016
Page 4 / 4