You are on page 1of 47

Energy Usage, GHG Reduction, Efficiency and Load Management Manual

Brewers Association

Water and Wastewater:


Treatment/Volume
Reduction Manual

Water and Wastewater: Treatment/Volume Reduction Manual

BrewersAssociation.org

table of contents
Acknowledgements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Section 1 Segment Profile: Water Usage &
Wastewater Generated by Craft Brewers . . . . . . . . . . . . . . . . . . . . . . . 6
1.1 Overview of Current Water Usage &
Wastewater Performance Trends. . . . . . . . . . . . . . . . . . . . . . . 7
1.2 Regulatory Drivers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
1.3 Non-Regulatory Drivers: Image/Brand, Community Ties. . . 10
1.4 Risks and Opportunities: Water Use Reduction and
Wastewater Management. . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Section 2: Data Management. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
2.1 Data Collection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
2.2 Ensuring Accuracy. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
2.3 Benchmarking: Key Performance Indicators (KPIs). . . . . . . . 18
2.4 Guidelines for Setting Measurable Goals and Objectives. . 19
Section 3: Usage & Reduction Best Practices. . . . . . . . . . . . . . . . . . . 20
3.1 Brewing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Best Practices - Mash Cooker, Lauter Tun, Boiling
Kettle and Whirlpool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Best Practices - Heat Exchangers . . . . . . . . . . . . . . . . . . . . . . 24
Best Practices Fermentation Vessels. . . . . . . . . . . . . . . . . . . 24
Best Practices - Yeast Disposal. . . . . . . . . . . . . . . . . . . . . . . . . 25
Best Practices - Filtration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Best Practices - CIP System. . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Best Practices - Vacuum Pumps . . . . . . . . . . . . . . . . . . . . . . . 27
Best Practices - Good Process Sesign. . . . . . . . . . . . . . . . . . . 27
Best Practices - Chase Water. . . . . . . . . . . . . . . . . . . . . . . . . . 27
3.2 Packaging. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Best Practices - Cask and Keg Washing. . . . . . . . . . . . . . . . . 28
Best Practices - Cask and Keg Filling. . . . . . . . . . . . . . . . . . . . 29
Best Practices - Glass Bottle Washing and Pasteurizing. . . . 29
3.3 Warehousing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
3.4 Support Systems (Utilities) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Best Practices - Cooling towers. . . . . . . . . . . . . . . . . . . . . . . . 30
Best Practices Steam generation. . . . . . . . . . . . . . . . . . . . . 31
Best Practices - Compressors. . . . . . . . . . . . . . . . . . . . . . . . . . 31

3.5 Food Service. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32


Best Practices - Dishwashing . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Best Practices Refrigeration. . . . . . . . . . . . . . . . . . . . . . . . . . 33
Best Practices - Grease Traps. . . . . . . . . . . . . . . . . . . . . . . . . . 33
Best Practices Dining area. . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Best Practices - Restrooms . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Best Practices Parking Lot/Landscape . . . . . . . . . . . . . . . . 34
3.6 Concerts/Events . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Section 4: On-Site Wastewater Treatment. . . . . . . . . . . . . . . . . . . . . . 36
4.1 pH Neutralization. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
4.2 Solids Removal. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
4.3 Biological Treatment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Section 5: Brewery Case Studies. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
5.1 Water Reduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Bells Brewery Kalamazoo, Michigan. . . . . . . . . . . . . . . . . . 40
Long Trail Brewing Company Bridgewater Corners, Vermont. . . 40
New Belgium Brewing Company Fort Collins, Colorado. . 40
Sierra Nevada Chico, California. . . . . . . . . . . . . . . . . . . . . . 40
Standing Stone Brewery Ashland, Oregon. . . . . . . . . . . . . 40
5.2 Wastewater Pre-treatment. . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Bluetongue Brewery Warnervale, Australia. . . . . . . . . . . . . 41
City Brewing Company, La Crosse, Wisconsin. . . . . . . . . . . . 41
Long Trail Brewing Company - Bridgewater Corners, Vermont. . . 41
Sierra Nevada Chico, California. . . . . . . . . . . . . . . . . . . . . . 41
Stone Brewing Company Escondido, California. . . . . . . . 42
5.3 Community Outreach. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Founders Brewing Company Grand Rapids, Michigan . . 42
New Belgium Brewing Company Fort Collins, Colorado. . 42
Appendix A: Tool Box. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Guidance and Checklists. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
On-Line Excel-Based Tools. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
References. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
Selected Web Links. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46

Cover photos Shutterstock, LLC. Interior photos provided by Antea Group unless otherwise noted.

Water and Wastewater: Treatment/Volume Reduction Manual

acknowledgements
This project would not have been possible without the support of many Brewers
Association members. The case studies they provided illustrate the creativity and
application of sustainability best practices in the craft brewing sector.
Our particular thanks go to the following core review team members, who provided
invaluable insight and direction throughout the development of this document:

Cheri Chastain, Sierra Nevada Brewing Company


Steve Crandall, Devils Backbone Brewing Company
Daniel Del Grande, Bison Brewing
Tom Flores, Brewers Alley
Matty Gilliland, New Belgium Brewing Company
Larry Horwitz, Iron Hill Brewery
Chris Opela, Brewmaster, Inc.
Chris Swersey, Brewers Association
Mike Utz, Boulevard Brewing Company

We would also like to thank the sustainability management consulting team from
Antea Group who developed this manual and related tools, and in particular
acknowledge Antea Groups Project Leader John Stier.

BrewersAssociation.org

introduction
Craft brewers are innovative leaders in the beverage sector.
The breweries take pride in developing new products and
processes that give both brewery employees and customers
options for sustainable living. Despite significant improvement
over the last 20 years, water consumption and wastewater
disposal remain environmental and economic hurdles
that directly affect breweries and the brewing process. It
is no surprise that many breweries have found innovative
solutions for water and wastewater management. These
solutions go beyond facility water conservation programs to
find collaborative, sustainable solutions for the community
and for the environment.
The abundance of clean, affordable
water in the United States has created
complacency among users and the
public. Businesses, municipalities and
academia all agree that the current
usage rate with future population
growth may create an unsustainable
pattern.

best practices in this manual will help provide tools needed


to work towards optimal efficiency, as well as to ease
potential future risks and enhance community value.

This manual is a consolidated resource for effective water


and wastewater management solutions in the craft brewer
segment. Solutions outlined can apply to all breweries,
regardless of location and operational size. It will provide
guidance for small brewers that are just beginning to
explore water and wastewater reduction programs, as well
as provide new ideas for brewers that are looking to improve
a well-established program or build
improved efficiency into expansions
I am convinced that, under
or new facilities. Brewers will also find
present conditions and with the
tools they can easily incorporate to
integrate water use reduction and
way water is being managed,
conservation measures into everyday
we will run out of water long
operations and to identify on-site
before we run out of fuel.
wastewater treatment opportunities.
- Peter Brabeck-Letmathe,
Chairman Nestl Corporation

Given these pressing concerns,


brewers need to be mindful of the future risks of cost and
supply, which are key staples of a growing business. While
the average water use ratio for a brewery is around seven
barrels of water to one barrel of beer, many craft brewers
are world leaders with ratios below three to one. Although
the payback for reducing water usage is typically longer
than recommended using standard financial calculators,
the long-term sustainability and growth of a business may
depend on the ability to efficiently use water resources. The

In addition, there are checklists,


resource lists, and other visual tools
throughout the manual and in
Appendix A to help breweries make informed decisions
about water usage and wastewater reduction opportunities.
Disclaimer: the following information provided constitute
suggestions that may or may not fit the need of each
brewery specifically. Brewers should proceed with caution
when implementing any new programs. It is not guaranteed
that operating under the guidance of this manual will lead to
any particular outcome or result.

The information presented is a pathway to effective and sustainable water and wastewater management
from start to finish. This information is organized into five sections:
1. Segment Profile: A discussion of water usage
and wastewater effluent trends, where to find
information on regulatory drivers, examples
of non-regulatory drivers, and risks and
opportunities for cost savings.

3. Best Practices: Guidance on best practices to


reduce water usage and wastewater generation
focusing on opportunities in the brewing process,
including packaging, warehousing, utilities, and
food service/events.

2. Data Management: A guide to identifying


the components of water and wastewater
information, establishing key performance
indicators and goals, managing water and
wastewater data, and benchmarking progress
toward goals.

4. Onsite Wastewater Treatment: An overview of


drivers for onsite wastewater treatment and
example technologies.
5. Case Studies: Selected brewery examples which
provide more detail of water and wastewater
reduction programs.

Water and Wastewater: Treatment/Volume Reduction Manual

section one
Segment Profile Water Usage &
Wastewater Generated by Craft Brewers

Beer is about 95% water in composition; however, the amount


of water used to produce a container of beer is far greater
than the amount of water contained in the beer that is
actually packaged and shipped out. Although water usage
varies widely among breweries and is dependent upon
specific processes and locations, the U.S. average is about
seven barrels of water for every barrel of beer produced. Most
craft brewers receive their water from municipal suppliers,
while a few use well water as an alternative source.
In addition to the water used in production, wastewater generation
and disposal presents another improvement opportunity for
brewers. Most breweries discharge 70% of their incoming water as
effluent. Effluent is defined as wastewater that is generated and
flows to the sewer system. In most cases, brewery effluent disposal
costs are much higher than water supply costs.
In many communities, breweries may be the largest
consumer of water and the largest source of organic effluent
that must be treated by the municipal treatment plant. This
presents unique supply and cost concerns. In the U.S., the
cost of incoming water from a municipal supplier (tap fee)
is relatively inexpensive compared to other brewery utilities.
When combining that cost with treatment (physical and
chemical) and effluent disposal costs, brewers are presented
with a reflection of the true or full cost of water. Establishing
this concept of full cost of water is an important factor in cost/
benefit analyses and will be discussed later in this document.

BrewersAssociation.org

Water awareness and conservation practices provide


an effective mechanism for brewers to reach out into
communities. Outreach efforts have a number of benefits,
including building brand image and being recognized as
an important part of the community.

Community Benefits
Economic:
Helps sustain community growth and business
investment.
Results in better bond ratings that help
communities in need of financing.
Helps cities and communities showcase their
waterfront areas and commitment to clean
water, thereby supporting new development
and encouraging related commerce.
Environmental:
Helps decrease the pollution in waterways that
harms wildlife and the ecosystem.
Reduces water and energy usage, leading to a
decrease in greenhouse gas emissions and less
strain on natural resources.
Ensures that community natural resources and
wildlife will be protected.

Segment Profile: Water Usage & Wastewater Generated by Craft Brewers

Within a brewery, there are four main areas where water


is used: brewhouse, cellars, packaging and utilities. In
addition, ancillary operations such as food service and
restrooms contribute to water usage.

BIER Brewery Water Use Ratios1


N=211
Range (2010) - 3 .26 - 7 .44 L/L
Improvement = 10%

4.74

Water Use Per Department


h1 Water/Total Beer

Packaging
38%

Utilities
20%

Water Use Ration (L/L)

Typical Brewery Water Use Per Area

2008

Brewhouse
25%

Cellars
17%

This section will identify the primary uses of water at craft


breweries. It will show trends in water usage and discuss
regulatory implications associated with water use. It will also
cover non-regulatory drivers as well as risks and opportunities
for cost savings.

1.1 Overview of Current Water Usage &



Wastewater Performance Trends
In 2011, the Beverage Industry Environmental Roundtable
(BIER) performed a study to benchmark water use in the
beverage industry and identify trends. In the graph below,
brewery data shows a consistent improvement in the
industry-wide water use ratio. Although BIER members are
usually larger brewers, this trend and the conclusions can be
replicated as an example for craft brewers.

4.52

2009

4.28

2010

This reduction over time seen in the brewing sector can


be attributed to a number of factors, including: efficiency
improvement, cost reduction, risk minimization, brand marketing
and image enhancement. Several factors influence this ratio,
such as packaging mix, pasteurization and volume brewed.

Conclusions Drawn From The Bier Study


The type of packaging used has a significant


influence on water use ratios. Smaller packages
(like 12 oz. bottles) tend to require more water use
than larger packages (like kegs).
The size of the facility has a major influence
on a brewerys water efficiency. Facilities with
larger production volumes tend to have lower
water use ratios.
Reducing water use reduces effluent load.
Focusing on water conservation will positively
affect both water and wastewater reduction in
the brewery.

Water and Wastewater: Treatment/Volume Reduction Manual

While specific risks vary among facilities, common examples of


water-related risks include water shortages and reliability, water
quality issues that require additional water treatment, increasing
water costs, and supply chain interruptions. In regions where
water is scarce, it can be challenging to meet basic human
needs for clean water and sanitation. Intense competition for
scarce water resources can occur among public water supplies,
agriculture, industry, and fisheries. In the United States, the aging
infrastructures for water supply will likely drive costs higher in the
future. Municipal water suppliers will soon be forced to find new
sources of capital to fund these initiatives.
Climate change is predicted to magnify many of these
water risks. Increasing global temperatures will likely
lead to increases in water demand, water scarcity, more
vulnerable ecosystems, and more frequent extreme
weather events.
Map Of Water Short States2

A recent survey of craft brewers was conducted to identify


the current status of wastewater treatment or effluent
discharges. The main questions focused on current costs
and regulations around effluent and wastewater treatment.

Distribution Of 76 Breweries Included In Survey


Present in bar chart?
19 Breweries 0-1000 Bbls
18 Breweries 1001-5000 Bbls
9 Breweries 5001-15,000 Bbls
10 Breweries 15,001-50,000 Bbls
9 Breweries 50,001- 100,000 Bbls
11 Breweries 100,001 + Bbls

Relevant key results of this survey included:


Not many breweries have a dedicated onsite
wastewater treatment system. Most discharge their
effluent to a municipal treatment center.
Some operations have some special collection of
high strength waste.
About half did not have any pre-treatment installed
at their facility to treat the effluent prior to the
municipal discharge. Those who had some pretreatment mainly adjusted the pH and settled and
removed the solids.
Wastewater costs are mainly determined based
on the incoming water purchased - only a few
brewers costs were based on the real flow of
effluent discharged (based on metering); the rest
were based on a formula or sampling.
Approximately one third paid an extra surcharge
based on the effluent strength (BOD and TSS).

Survey Insight
Today, a small craft brewer may not be the focus of regulatory
restrictions in drought-prone regions. With increasing
population and demand for water, brewers can expect to
experience increased scrutiny and water-related business risk
in the near future.


When looking at wastewater and effluent discharges
in craft breweries, there is also a trend towards a more
regulated (from local authorities) and more controlled
system. Craft brewers in different states and cities are
increasingly questioned about wastewater or need to
provide flow and chemical sampling data.

BrewersAssociation.org

From a cost perspective, it is important to reduce


water usage, not only to purchase less water,
but to reduce wastewater costs based on the
amount of incoming water purchased.
Onsite pre-treatment will reduce the strength
of the effluent being discharged and may be
required by local authorities through ordinance or
permit. Discharge limits are being applied more
often to brewers because of the high organic
load untreated brewery effluent may contain.

Segment Profile: Water Usage & Wastewater Generated by Craft Brewers

This manual focuses on reducing water and effluent first,


and then reducing the strength of the effluent.

1.2 Regulatory Drivers




Demand for water in the U. S. more than tripled between
1950 and 2000. This increase in demand has put further stress
on water supplies.
Experts believe that in 2013, more than 70% of the United
States is experiencing or will experience some type of local,
regional or statewide water shortage. By 2025, four billion
people - about half of the worlds population - will live in
severe water stress conditions.

Environmental Drivers


Stress on water supplies


Risk of (local) water shortage
Risk of (local) water pollution

various stakeholders involved. These are often extended


legal proceedings around state and local water rights. In
most cases, the craft brewer will not be directly involved
or aware of these activities; however, these actions
will drive decisions that will impact the availability and
cost of water and wastewater services provided to the
brewer. Due to increasing populations and technology,
more resources are constantly needed to match lifestyle
expectations. With so many different needs for this scarce
resource, priorities must be established. How much water
should be used to extract natural gas, produce electricity,
irrigate agricultural crops, or used for human consumption
in the form of packaged beverages?
Congress has passed legislation and the U.S. EPA has
introduced rulemaking to protect surface water bodies from
pollution. The Clean Water Act regulates the discharge of
pollutants into U.S. waters and establishes quality standards for
surface waters. Under the Clean Water Act, the following rules
may directly or indirectly impact craft brewers operations.
Common legal drivers under the Clean Water Act

In addition to human needs, protection of endangered


species and ecosystems will compete with available water
supply. It is likely that the U. S. Environmental Protection
Agency (U. S. EPA) will introduce new laws and regulations
that keep water in-stream for species protection.
The ongoing debate of water for human consumption,
economic development, species protection, recreation,
tourism and flood control will continue into the future.


Excessive water pollution can impact ecosystems. The high
organic nature of brewery wastewater causes oxygen in
a surface water to be depleted at a rapid rate, which
negatively impacts living species and biodiversity. A
number of water bodies in the United States remain above
pollution levels considered safe for ecosystems. Additional
regulatory restrictions are expected in the near future to
address this problem.
An impaired waterway is a river, lake, stream, pond, bay, or
estuary that does not meet the water quality standards of the
Clean Water Act and the state. The graphic below illustrates
the extent of impaired waterways in the United States.
As a result of shortages, water allocation issues are
escalating between political subdivisions because of the

Effluent Limitations Guidelines: national standards


for industrial wastewater discharges to surface
waters and publicly owned treatment works.
Pre-treatment Streamlining Rule: pre-treatment
programs for the control of industrial discharges into
sewage collection systems.
NPDES Permit Program: regulating point sources
(single, identifiable sources of pollution such as pipes
or man-made ditches) that discharge pollutants
into U.S. waters.
Sewage Sludge (Biosolids) Rule: requirements for
the final use or disposal of sewage sludge.
Total Maximum Daily Load (TMDL) and Impaired
Waters Rules: states, territories, and authorized tribes
are required to develop lists of impaired waters that
are too polluted or degraded to meet set water
quality standards.

In addition, the Safe Drinking Water Act (SDWA) sets legal


limits on levels of certain contaminants in drinking water.
In addition to these regulatory guidelines, there are
also regional compacts that can govern water use and
wastewater effluent. There are groups (i.e., The Great Lakes
Compact) working together to protect local watersheds. It
requires all water-intensive businesses within the watershed
to implement water conservation practices.

Water and Wastewater: Treatment/Volume Reduction Manual

Photo Of Community Clean Up3


Great Lakes Compact
The Great LakesSt. Lawrence River Basin Water
Resources Compact is a legally binding interstate
compact among the U.S. states of Illinois, Indiana,
Michigan, Minnesota, New York, Ohio, Pennsylvania
and Wisconsin. The compact details how the states
manage the use of the Great Lakes Basins water
supply and builds on the 1985 Great Lakes Charter
and its 2001 Annex. The compact is the means
by which the states implement the governors
commitments under the Great Lakes-St. Lawrence
River Basin Sustainable Water Resources Agreement
that also includes the premiers of Ontario and
Quebec. The interstate compact seeks to ban the
diversion of Great Lakes water, with some limited
exceptions, and set responsible standards for water
use and conservation within the basin.

There are also general prohibitions for discharge to


publicly owned treatment works (POTW). For example,
in most local ordinances, there is a prohibition on pass
through or interference (A User may not introduce into
a POTW any pollutant(s) which cause Pass Through or
Interference).
From a practical standpoint, this suggests that brewery
wastewater must be screened for large particles (like bottle
caps, broken glass, grains, etc.) and chemically pretreated
for pH, temperature, and organic concentration.

Some breweries partner with community members and


local organizations to conduct projects that improve water
use, water quality, and/or water management resources.
Consider using Lean methodssuch as a wastewater walk
(to identify leaks and unnecessary drainage), kaizen event,
or even a Lean design eventto rapidly brainstorm and test
improvement ideas for projects, and include community
stakeholders in those efforts.

Key Efforts

1.3 Non-Regulatory Drivers: Image/Brand,



Community Ties
In addition to regulatory drivers, brand image and
positioning will drive many water and wastewater
improvement programs at craft breweries. These efforts start
with employees and can extend into the community.
Many breweries educate and engage employees in
water-efficiency efforts at the facility and encourage
them to adopt similar practices at home (e.g., check for
leaks, use efficient appliances and faucets, turn off water
when not in use, etc.). Changing the water use culture in a
brewery can often be a challenge. Incentives, in the form
of monetary or visual recognition, can play an important
role in this effort.

10

BrewersAssociation.org

World Water Day - Every year on March 22, the UNWater Partnership, comprised of 28 different UN
organizations, celebrates World Water Day. World
Water Day focuses public attention on waterrelated issues and on sustainable management
of freshwater resources. There are events held all
around the world, providing great opportunities for
brewers to communicate efforts to help conserve
this precious resource.
The Clean Water Act 40th Anniversary - The Clean
Water Act is one of the landmark environmental
laws in the U. S. The year 2012 marked its 40th
anniversary.

Segment Profile: Water Usage & Wastewater Generated by Craft Brewers

Along with the value of community engagement, these


strategies can improve the impact the facility has on local
water resources. Some leading global beverage companies
have set goals to replenish the local water supply with at
least the amount of water consumed.

TCCC Water Stewardship Campaign


The Coca-Cola Company set three water stewardship
goals for its global operations. These goals are:
1. Reduce: By 2012, improve water efficiency by
20% compared with a 2004 baseline. In essence,
this is an efficiency target not unlike many other
beverage companies have set. It is measured as
water use ratio, the amount of all water needed
to make one liter of beverage.
2. Recycle: By 2010, return to the environment at a
level that supports aquatic life the water used in
the system operations through comprehensive
wastewater treatment. This is a water treatment
standard, whereby the company strives to clean
all wastewater from its operations to a very high
standard of cleanliness, often exceeding local
requirements. The goal is called recycle because the
resultant discharge is clean enough to be recycled
in natures water cycles without harming aquatic life.
3. Replenish: By 2020, safely return to nature and
to communities an amount of water equal to
what is used in the finished beverages and their
production. This goal depends on successful
community water partnership programs and
eco-systems projects to be reached. For each
can of Coca-Cola beverage an equivalent
can of water has to be given back, either to
communities in the form of potable water
(where this was not available before) or as clean
water back to an eco-system. The latter can be
achieved in a myriad of ways. For example,
replanting with native vegetation can increase
the retention of water in the basin. Increasing
groundwater recharge through reforestation
or artificial aquifer recharge could also be
considered as a replenishment activity. CocaCola depends on external and independent
validation of the amount of replenishment
water they can claim for replenishment.

Reducing water use and improving management processes


can provide a competitive marketing advantage. Customers

and employees alike see proactive efforts to improve the


environment as an important and desirable attribute. This
increases customer loyalty and improves a brewerys ability
to attract and retain employees.
People around the world view water issues as a key sustainability
challenge. For example, more than 90% of the 32,000 people
polled for a GlobeScan and Circle of Blue survey in 2009
perceived water pollution and freshwater shortage to be
serious problems (70% considered them very serious problems).
Some companies can tap into significant market niches by
offering customers water-efficient choices and solutions.

Summary of Circle of Blue Survey


General concerns
96% agree that it is important for all people to
have adequate, affordable drinking water.
88% worry that fresh water shortages will become
an increasingly severe problem worldwide.
Particular concerns
57% is primarily concerned around water pollution
56% is concerned about the lack of safe
drinking water
47% is concerned about the lack of water for
agriculture
35% is concerned about the cost of water
Who should be held responsible ensuring clean water
in communities?
44% water companies
41% the government
39% large companies (Note: 79% think that
companies need to be a part of the solution)
30% individual citizens
Little responsibility is placed on farmers and NGOs
Last, a majority (60%) of Americans believes that
individuals have the ability to contribute to the
solution when addressing water shortages, and 75%
indicate they need more information before they
would feel able to help protect water.

Community ties give breweries the opportunity to promote


water conservation outside the four walls of the facility,
further supporting the brand and image. Saving water
and educating employees can be demonstrated through
projects like rainwater harvesting.

Water and Wastewater: Treatment/Volume Reduction Manual

11

5 Seasons Brewery Rainwater Harvesting

Water Cost Considerations

Not only were the folks behind this microbrew


looking to save water, they want to educate
people. According to Randy Kauk, President of
RainHarvest Systems:

Common Costs Associated with Water Use (Box 7)

We are extremely excited with our new


partnership with 5 Seasons Brewery. We believe
it uniquely demonstrates the broad array of
applications where rainwater can be used
instead of chemically treated drinking water; plus
it is a great way to create public awareness of
rainwater harvesting.

Addressing water and wastewater issues should be critical


elements on any brewerys agenda. Linking local efforts
to larger national and global events is one effective
approach to raising awareness among employees and in
the community.

1.4 Risks and Opportunities: Water Use Reduction



and Wastewater Management
Water supply and wastewater discharges present a number
of risks and opportunities for craft brewers. As with any
business investment, a cost benefit analysis should support
any decision to expend resources in these areas.
Historically, capital to support water usage reductions has
been difficult to justify due to the low tap fees associated
with municipal water supplies in the United States. Even using
the full cost of water accounting methods, water reduction
and re-use projects often do not meet brewery hurdle rates
for expenditures. Many craft brewers have justified these
projects based on image and community drivers alone.

12

BrewersAssociation.org

Raw Material Costs:


Water purchased from utilities; marginal costs
of purchasing additional water versus costs
of conservation
Cost of water treatment, filtering, and
softening before use
Costs for chemicals needed to treat and
manage water
Energy Costs:
Cost of energy to heat water
Cost of energy to pump water from its source,
or within the facility itself
Energy and labor costs for operating and
maintaining water-using equipment
Pollution Control Costs:
Wastewater and stormwater service rates,
including surcharges
Total cost of treating wastewater for
disposal, including labor, energy, chemicals,
equipment, and residual disposal
Marginal costs of increasing effluent
treatment capacity when water demand
increases
Regulatory Compliance Costs:
Labor costs for regulatory compliance
activities such as completing permit
applications,
monitoring
compliance,
and reporting wastewater discharges to
regulatory agencies

It requires a lot of energy to move and use water, so water


savings result in cost savings. Approximately 20% of all the
energy used in the state of California is used to move,

Segment Profile: Water Usage & Wastewater Generated by Craft Brewers

use, and treat water. Although water savings projects are


often not cost effective due to the low price of water in the
US, when the electricity savings are also included, it adds
another layer of savings.

The price of water continues to increase. This increase has


affected the cost of utilities in many municipalities.
Increase In Municipal Utility Costs

The largest driver to date has been wastewater


compliance. In order to meet wastewater effluent
regulatory requirements, many craft brewers have initiated
reduction projects. Most breweries are charged for their
wastewater based on the incoming water purchases as
well on the strength of the effluent.

$150

$150

$150

$150

$150

$150

$100

$100

$100

$100

$100

$100

$50

$50

$50

$50

$50

$0

$0

$0

$0

$0

2010

2011

2012

San Diego

2010

2011

2012

2010

2011

2012

San Antonio

Santa Fe

2010

There are many incentives that focus on water use and


wastewater reduction. Reducing the effluent load and
decreasing water use will reduce bottom line costs. Brewers
should recognize that reduced water usage will result in
lower wastewater discharges; however, the concentrations
of pollutants in this case may be higher. It is important to
check this potential increase in concentration against
regulatory limitations.

2010

2011

2012

$50

2010

Milwaukee

2011

$0

2012

New York

2011

2010

2011

2012

Philadelphia

2012

50 Gallons/Person/Day

50 Gallons/Person/Day

50 Gallons/Person/Day

100 Gallons/Person/Day

100 Gallons/Person/Day

100 Gallons/Person/Day

150 Gallons/Person/Day

150 Gallons/Person/Day

150 Gallons/Person/Day

Trends in consumer prices (CPI) for utilities


400

360

320

280

240

The following graphic illustrates typical annual wastewater


surcharges for different sized breweries.

200

160

Example Of Typical Annual Wastewater Surcharges


2bbl ww/bbl
beer

4bbl ww/bbl
beer

10bbl ww/bbl
beer

80

1,000 - 15,000

$550 - $8,200

$1,100 - $16,400

$2,800 - $41,000

15,000 - 100,000

$8,200 - $54,700

$16,400 - $110,000

$41,000 - $274,000

1000,000 - 600,000

$54,700 - $328,000

$110,000 - $656,000

$274,000 - $1,700,00

6,000,000 - 2,000,000

$328,000 - $1,100,000

$656,000 - $2,200,000

$1,700,000 - $5,500,000

>2,000,000

>$1,1,00,000

>$2,200,000

>$5,500,000

Water & sewer

2010

2008

2006

2004

2000

2002

1998

1996

1994

1990

1992

1988

1986

1982

1984

1978

40
1980

Annual Beer
Production
(bbl)

120

CPI

When considering the above items, it becomes clear that


water management and wastewater minimization efforts
make good business sense from both a cost savings and
from a business continuity perspective.

Water and Wastewater: Treatment/Volume Reduction Manual

13

section two
Data Management
Data management is more than just a component of a
successful program it is a necessity for a successful business
strategy. As discussed previously, there are both risks and
opportunities in water and wastewater management.
Making informed business decisions to minimize risk and
maximize opportunity requires effective data management.
Effective Data Management System

Where to start?
1.
2.
3.
4.

Where is the water going?


How much water is used? What are typical values?
How much water is discharged?
Whats in the water discharge? What are typical
values?
5. How can water use and discharge be managed?

GATHERING
EVIDENCE

TARGET
SETTING

well as installing water meters on processes that use large


amounts of water and have a history of inconsistency.
Understanding water use is critical to starting an effective
conservation program.

WORKING
WITH DATA

Brewery Size Versus Wastewater Generation


Annual Beer Production

READING AND
ANALYSING DATA

This section covers best practices in data management,


from establishing a data collection routine and ensuring the
data is accurate, to creating key performance indicators
and setting goals.

2.1 Data Collection




Successful data management enables cost-effective
decisions to be made. Data management often goes
beyond collecting usage and cost data from a monthly
utility invoice. It includes identifying process areas, support
functions, and facility operations that have the greatest
opportunities for improvement. Strategies include tracking
water metrics as part of process improvement activi-ties, as
14

BrewersAssociation.org

ww @ 2bbl ww/bbl beer

ww @ 4bbl ww/bbl beer


bbl/year

gallons/
day

ww @ 10bbl ww/bbl beer


bbl/year

gallons/
day

bbl

gallons

bbl/year

gallons/
day

5,000

155,000

10,000

850

20,000

1,700

50,000

4,200

1,500

465,000

30,000

2,550

60,000

5,100

150,000

12,700

300,000

9,300,000

800,000

51,000

1,200,000

102,000

3,000,000

255,000

1,000,000

31,000,000

2,000,000

170,000

4,000,000

340,000

10,000,000

850,000

The ability to collect or estimate water consumption


data by process step can lead to more effective water
conservation practices.
The previous section identified five main uses of water in a
brewery or brewpub:
1. Brewhouse
2. Cellars
3. Packaging
4. Utilities
5. Ancillary
A third party utility bill will often provide usage and cost
data for the main water meter only. Creating a formal mass
balance of water and wastewater in the brewery is often

Data Management

costly and resource intensive; however, there are some data


management steps that can be completed early in a water
conservation program using a survey checklist.

Installing sub-meters at key locations is the best way


to quantify and segregate water usage. Pulse output
mechanical meters allow for automatic data collection,
reducing measuring errors, and eliminating manual reading
of the meters.

Survey Checklist Example


1. Map the brewerys water distribution network
and mark the routes of major pipes and drains on
the site plan. Are the drawings up to date?
2. Identify the major points at which water is used.
3. Identify the major of wastewater discharge.
4. Identify the content of the effluent (yeast, trub,
etc.), if possible.
5. Estimate the amount of water used and
discharged at each major point.
6. Identify the water quality and availability at each
[major] point.
7. Include designations for hot, cold and
drainage systems.
8. Check water use in different areas of the brewery
when production has ceased. If liquid is flowing
through pipes or drains, either there is a leak or
equipment has been left switched on (potential
energy savings).
9. Label pipework, valves and manholes for easy
identification.

This task and checklist is often helpful for a new employee to


fully and quickly understand the brewery and its processes.
These checklists are also a good opportunity to partner with
interns from a local university or trade program.
Keep in mind that a detailed water balance can be difficult to
do because of evaporation losses. Evaporation, particularly
from refrigeration plants, can account for as much as 25%
of incoming water usage. Wastewater treatment also has a
high rate of evaporation.

Common Survey Findings








Unidentified and cross connections


Broken and incorrectly set valves
Leaks
Excessive, unnecessary and unknown use
Clean water discharges directly to effluent (e.g.,
cooling water)
Unauthorized discharges to effluent
Surface water drainage from potentially
contaminated areas

Using Water Meters To Identify Opportunities


Revised procedures help brewery to reduce hot
liquor waste
The Brewery operated by Hardys & Hansons had a
single, cold liquor tank, situated outside the Brewery
on the South side. A second tank, twice the size of
the first, was subsequently installed to meet authority
storage requirements. Flow into and out of the tanks is
controlled from the brew-house using actuated valves.
During hot weather, the temperature of the cold
liquor rose from 12C to 20C. This, combined with
an outdated heat exchanger, produced an excess
of low quality hot liquor which had to be diverted to
drain. The wort also required further cooling in the
fermenters before a brew could begin.
Installing water meters helped to identify these
problems. Procedures have been revised to
allow the brewer to bypass one of the cold liquor
tanks, depending on demand and the ambient
temperature. Cold liquor storage time is now
minimized and temperature gain reduced. A further
reduction in hot liquor waste has been achieved by
automating flow through the heat exchanger and
adding a chilled water section. In addition, the hot
liquor retained is of a higher quality and processing
has been speeded up.

A single meter isnt capable of providing enough details on


water usage in different process steps, so installing additional
meters is highly recommended. If installing sub-meters is not
possible, there are several other ways of estimating water
volume. In places where water is transported in a constant
flow, read the pump capacity and multiply this flow by the
operating hours. Be careful when using this method and
dont assume that the equipment is actually doing what
it says on the nameplate. Be sure to check the numbers
against expected outputs.

Water and Wastewater: Treatment/Volume Reduction Manual

15

Flow Measurement Considerations

Wastewater Flume

A flume is an open artificial water channel, in the form


of a gravity chute that leads water from a diversion
dam or weir completely aside a natural flow. A flume
can be used to measure the rate of flow. Specific
designs include the Venturi, Parshall, Palmer-Bowlus,
trapezoidal, and H-Flume.

How accurate does the data have to be?


Does the data need to be trended or will a oneoff measurement suffice?
What is the size and material of the pipe?
What is the operating pressure and temperature?
What is the expected flow range (min to max)?
Are there any existing meters that can be
connected to a data logger or transmitter?
When a tank is filled on demand, which is based
on low-level/high-level switches, count the
number of filling cycles. Determine the time it
takes to fill one gallon in a bucket. This can help
estimate the water flow.

As described in the previous section, many utility


companies estimate wastewater effluent volume based
on a percentage of incoming water billings. There
are allowances for domestic use and calculating the
amount of water leaving the site in the product and
through evaporation. This method requires assumptions
on the amounts of water used in flush toilets, wash basins,
canteens, etc. When using this method, inform the utility
of any changes in staff numbers or modifications to staff
facilities. These changes may affect water consumption
and the allowance for domestic use.
Determine if rainwater is discharged to the same sewer
system as process effluent. It may be beneficial to separate
these flows, especially when there is an onsite pre-treatment
facility.

DUMPI

KE

NG

DR

A simple way to separate


sewage water (effluent)
and surface water (rain water)
is to label or color-code all
drains. This will allow easy
identification of the
different pipes. 

NO

Labeling Process And Storm Drains

AI
N S T O LA

Unlike incoming water, it is important to sample other parameters


besides volume on a regular basis, since most utilities have a
surcharge cost for brewers based on organic and solids sent
to the municipal treatment system. A surcharge is established
to recover the cost of transporting and processing wastewater
that exceeds levels normally associated with typical household
(domestic) wastewater levels.

Typical Domestic Wastewater Levels


Biochemical Oxygen Demand less than 400 ppm
Total Suspended Solids less than 400 ppm
Oil & Grease less than 100 ppm

A surcharge by a municipality is typically determined by using


laboratory test results from wastewater samples taken from the
discharge of the brewery where it enters the municipal system.
The current water consumption and established municipal
surcharge rates are used to calculate additional fees beyond
those required of domestic wastewater discharges.
Before contacting your municipal water agency, an effective
first step for a responsible brewer involves contacting a private
laboratory to analyze a composite wastewater sample. This
knowledge can help to establish the most effective strategy
for approaching the water agency.
Samples can be taken either by the brewery or by the
utility and can be either spot samples or 24-hour composite
samples. The choice will depend on the utility requirements.

Composite Wastewater Sampling


Installing a wastewater meter or demonstrating a different
ratio may be beneficial for a craft brewer; however, flow
measurement becomes quite inaccurate when solids are
present in the effluent, as is the case with brewing effluent.
The most accurate flow measurements can be obtained
using a flume, although it is usually not easy to find the right
conditions for installation.
16

BrewersAssociation.org

A 24-hour sample will generally give a more reliable


measurement, since any peaks due to the variations
in the brewery process are leveled. A flow-weighted
composite sample can be taken, which is the most
accurate measurement, as it compensates for the
flow variations of the effluent during the day.

Data Management

Be aware that brewery effluent is highly degradable and


thus samples need to be stored properly. Samples must be
kept at the proper temperature and measurements should
be performed as soon as possible. Any pH measurements
should be performed immediately, since the result will vary
after a few hours.
Each brewery will have different wastewater concentrations;
however, there are typical values and ranges of key
components that have been associated with untreated
brewery effluent.
Typical Ranges Of Brewery Untreated End-Of-Pipe
Wastewater Effluent
PARAMETER

TYPICAL RANGE

Water to beer ratio

4 - 10 liter/liter

Wastewater to beer ratio

1. 3 - 2 liter/liter lower than


water to beer ratio

Biochemical Oxygen Demand (BOD)

600 - 5,000 ppm

Chemical Oxygen Demand (COD)

1,800 5,500 ppm

Nitrogen

30 - 100 ppm

Phosphorus

30 - 100 ppm

pH

3 - 12

Total Suspended Solids (TSS)

200 1,500 ppm

Typical Ranges Of Brewery Pre-Treated End-Of-Pipe


Wastewater Effluent
PARAMETER

TYPICAL RANGES

BOD

100 - 400 ppm

pH

6-9

TSS

50-500 ppm

Although each brewery is different, breweries can generally


achieve an effluent discharge of 3 to 5 liter/liter (considered
an industry best practice goal) of sold beer (exclusive of
cooling waters).
Effluent from individual process steps is variable. For example,
washing bottles produces a large volume of effluent that
contains only a minor amount of the discharged organics
from the brewery. Effluent from fermentation and filtering are
high in BOD and low in volume, accounting for about 3% of
total wastewater volume but 97% of BOD. The average pH
of combined effluent is around 7. But this can fluctuate from
3 to 12 depending on the use of acid and alkaline cleaning
agents. The pH of waste beer usually ranges between 4 and
5. CIP effluent temperatures average about 86F.
Most brewers discharge over 70% of their incoming water
as effluent.

Main Areas Of Wastewater Generation


SOURCE

OPERATION

CHARACTERISTICS

Mash Tun

Rinsing

Cellulose, sugars, amino acids. ~3,000 ppm BOD

Lauter Tun

Rinsing

Cellulose, sugars, spent grain. SS ~3,000 ppm, BOD ~10,000 ppm

Spent Grain

Last running and washing

Cellulose, nitrogenous material. Very high in SS (~30,000 ppm).


Up to 100,000 ppm BOD

Boil Kettle

Dewatering

Nitrogenous residue. BOD ~2,000 ppm

Whirlpool

Rinsing spent hops and hot trub

Proteins, sludge and wort. High in SS (~35,000 ppm). BOD ~85,000


ppm

Fermenters

Rinsing

Yeast SS ~6,000 ppm, BOD up to 100,000 ppm

Storage tanks

Rinsing

Beer, yeast, protein. High SS (~4,000 ppm). BOD ~80,000 ppm

Filtration

Cleaning, start up, end of filtration, leaks during


filtration

Excessive SS (up to 60,000 ppm). Beer, yeast, proteins. BOD up


to 135,000 ppm

Beer spills

Waste, flushing etc

1,000 ppm BOD

Bottle washer

Discharges from bottle washer operation

High pH due to chemical used. Also high SS and BOD, especially


thru load of paper pulp.

Keg washer

Discharges from keg washing operations

Low in SS (~400 ppm). Higher BOD.

Miscellaneous

Discharged cleaning and sanitation materials. Floor


washing, flushing water, boiler blow-down etc.

Relatively low on SS and BOD. Problem is pH due to chemicals


being used.

Water and Wastewater: Treatment/Volume Reduction Manual

17

2.2 Ensuring Accuracy




After data measures for water usage and wastewater
are identified and quantified, the information should be
reviewed for accuracy. Without reliable data, especially as
the starting point, it will be difficult to track progress. Having
accurate initial data is also important to monitor for new
water usage and wastewater generation, identify mid-point
goal milestones, and cost savings. To verify the data, three
key questions are:

Does the volume of water used and wastewater


generated appear reasonable based on the
amount of beer produced?
Is the volume of water used and wastewater
discharged consistent with historical volumes (e.g.,
last month and the same time last year)?
Is there any missing data that should be included
(e.g., new wastewater stream, or one-time beer
dump due to quality issues)?

After the data is verified and approved, the information


should be shared with team members, such as brewery
employees and management. Breweries that have
collected information for several years can report progress
toward water reduction goals and overall cost savings. It is
always important to openly communicate both the starting
point and the ultimate goals and targets that the brewery is
aiming to achieve.

2.3 Benchmarking: Key Performance



Indicators (KPIs)
Key Performance Indicators (KPIs) are defined by breweries
to measure the effectiveness of a reduction program over
time. Defined KPIs are standard points of reference that
provide valuable insight into a programs performance.
KPIs are usually defined as a rate or ratio (e.g., total water
use ratio) instead of a quantitative total, such as total
water used.

18

BrewersAssociation.org

Typical KPIs for Water


Facility-Wide Metrics
Volume of water used each month or other
appropriate time period (e.g., gallons/month or
gallons/shift)
Volume of wastewater (e.g., gallons/month or
gallons/shift)
Water used for specific end uses (e.g., gallons/
per month for outdoor irrigation, cooling water
evaporation, heated process water, bathrooms
and kitchens, etc.)*
Metrics Normalized to Production
Volume of water used per product (e.g., gallons/
pound of product, gallons/product)
Volume of wastewater discharged per product
(e.g., gallons/pound of product or gallons/product)

KPIs are often used internally to manage a water reduction


program by encouraging comparison over time. Initially, there
may only be one or two KPIs that focus on basic water streams.
As the water management program matures, KPIs may
change or new KPIs may be created to encourage continuous
improvement, especially in areas that may be lagging behind.
Once KPIs have been defined, breweries should establish an
annual internal benchmarking plan. Assign data management
roles to brewery personnel so that the data set can be built
up throughout the year. Repeat the benchmarking exercise
each year and report progress on goals.
When there is confidence in the accuracy and performance
of the brewery water data set, consider sharing benchmarking
results with external stakeholders, customers, and peers.
Sharing this information could be as simple as including statistics
on a brewery tour, including performance information on the
brewery website or social media outlets, such as blogs or Twitter
feeds, or producing a basic sustainability report document. As
facility benchmarking continues to mature, the brewery may
also consider reporting performance to external stakeholders.

Data Management

Data Flow Progression


Considerations For Goal Setting

Data verification

Set internal goals

Assign data management


responsibilities to
employees

Gather monthly data report

Prioritize opportunities: What is most important for


the brewery in the short term? What opportunities
are good for the brewery, but could wait a few
years for implementation?
Set meaningful targets and align goals with a
philosophy: Make sure goals are meaningful
and realistic building the brewerys philosophy
into water reduction goals will boost interest
and enthusiasm for the program. Set attainable
performance targets to ensure the brewery is
effectively working toward goals.
Establish a benchmarking plan: A benchmarking
plan will ensure continuous improvement over
time. Plans will vary based on brewery size and
program maturity.
Look at the big picture: Think beyond primary
goals to larger objectives (e.g., employee
engagement in water reduction, expanding the
understanding of water across the entire brewery
lifecycle, from supplier to consumer).

Verify accuracy of data

Analyze data and track


progress with respect to goals

Targets are designed to be more stringent and specific than


goals. Often, targets are set in response to goals. For example,
the brewery may set a goal of 6 liters of water per liter of
beer produced by 2020, and set targets for a continuous
improvement of 20% water reduction every two years. While
goals should align with the brewerys philosophies and may
be more aspirational, targets should be more realistic and
attainable.


Review KPIs and set new goals


Once the water management program is established
and KPIs have been calculated for several periods,
benchmarking the brewery to peer companies and sector
averages will help gauge the effectiveness of the program.

2.4 Guidelines for Setting Measureable Goals



and Objectives
Establishing goals and objectives to reach a desired future
state will drive continuous improvement in the water
reduction program. Several important things to consider
when defining objectives and setting goals:

What are good targets?


Have a set deadline
Are ambitious, yet attainable
Are quantifiable
Are relevant to program improvement
Can be reassessed and enhanced after original
target is met

New Belgium Brewing Company Water Target


New Belgium Brewing Company has defined water
stewardship as responsible consumption through
minimizing waste and protecting watersheds. They
have set a water use target of 3.5:1.0 ratio by 2015.

Water and Wastewater: Treatment/Volume Reduction Manual

19

section three
Usage & Reduction Best Practices
Increasing yield and reducing beer loss should always be
the first priority in any resource efficiency program. Reducing
the amount of beer being spilled and wasted saves water,
energy and ultimately, provides an immediate cost return.

more attractive, especially if future price increases are


taken into account and value is put on business continuity
and water reliability.
Full Cost of Water

Water reduction programs usually follow beer loss programs.


There are usually some quick fixes for brewers just starting
water reduction programs. The costs of even minor leakage
is often overlooked or underestimated.

Costs
Associated
with water
use

Price of
incoming
water

Sewer
Service
Charge

Cost of energy and


chemicals needed to
process water

Labor and other


costs associated
with water
processing and
treatment

The price on the water bill

As previously discussed, water reduction projects have been


difficult to justify based on the cost of water; however, if the
full cost of water is calculated, some projects may become

The cost of water use at a facility can be much


greater than the amount on the water bill.

Cost of Water Leaks


Leak detection is cost-effective. The Eagle Brewery operated by Charles Well Ltd has a comprehensive utility monitoring
system that covers the water supply to the main process areas. Since it was installed, the system has paid for itself
many times through rapid identification of leaks. Continuous metering allows the brewery to identify changes in
normal water use due to leakage from a single component, like a valve, as well as identifying major leaks. Example
faults and the estimated potential hourly costs are listed below
FAULT

20

BrewersAssociation.org

ESTIMATED POTENTIAL COSTS (U.S.$/HOUR)

Hose left on

14.00

Bottle pasteurizer rinse jets left switched on

14.00

Bottle rinser left switched on

6.10

Leaking float valve on the cooling tower

4.10

Leaking ball valve on the bottle pasteurizer

2.00

Leaking ball valve in the keg plant

1.90

Pasteurizer header tank top-up valve jammed

1.65

Usage & Reduction Best Practices

When calculating the potential savings from a particular


measure, there may be savings in the cost of:






Water use
Onsite water pumping and associated maintenance
Water treatment (chemicals, filter backwash, etc.)
Water heating or cooling
Effluent pumping
Effluent treatment
Effluent discharge

Example Of Total Unit Costs


Table 3: Costs Associated with Water Used in an Industrial Process
Activity

Unit Cost ($/1000 Gallons)

City Water Purchase

$3.55

Sewer Rate

$3.99

It is important to challenge the status quo (this is the way


it has always been done) when looking for water and
wastewater reductions. The following questions can be
useful when starting a water reduction initiative or when
reviewing a mature program on a regular basis:
Is the process or activity necessary?
Is it necessary to use water?
Why does the process use so much water?
Can the amount of water be reduced?
Can lower quality water be used?
Can water be recovered elsewhere?
Is the process authorized and legal?
Is it necessary to produce wastewater or effluent?
Is clean water going down the drain?
Is the discharge authorized and legal?
Would it be cost effective to treat wastewater or
effluent onsite for re-use?

Deionized using reverse osmosis


Equipment

$0.57

Energy

$1.20

Labor

$1.43

Total Deionized water


Deionized water (flexible cost)*

$2.31
40% x $2.31 = $0.92

Ways to reduce water use range from simple strategies, such


as adjusting flow or installing water-conserving equipment,
to more involved options, such as reusing water or switching
to a low-water or waterless process.
Impact Difficulty Matrix

Wastewater treatment
Sludge disposal

$3.46

Treatment chemicals

$2.44

Energy

$0.32

Labor

$6.25

Total wastewater treatment


Wastewater treatment (flexible cost)*
Total cost of water

High

$12.47
40% x $12.47/gallon = $4.98

In

cr
ea
sin
g

$13.44

* Flexible cost savings of conserved water is estimated to be 40 percent of total investment cost

Besides these total costs, some additional cost savings may


be calculated from:
Increased beer production
Greater recovery of materials suitable for sale as
animal feedstock
A delayed requirement of additional water storage
capacity
Increased production without having to upgrade
the water supply system
Lower capital expenditures on a planned or future
effluent treatment system

Low

Low

De

sir
a

bi

lit
y

High

Difficulty
There are five general types of water-saving strategies,
ranging from easy to more difficult implementation, but also
moving to a bigger impact. Consider these strategies when
brainstorming ideas in cross-functional team meetings and
other improvement efforts.

Water and Wastewater: Treatment/Volume Reduction Manual

21

Moving From Simple To More Complex Actions


Adjust water flow
Modify existing equipment or install
water-saving devices
Change to more water-efficient equipment
Reuse or recycle water (treat if needed)
Shift to a low-water or waterless process

Key things to consider when starting water minimization efforts


Prioritize opportunities: What is most important for


the brewery in the short term? What opportunities
are good for the brewery?
Consider water efficiency improvements in the
context of other process improvements and lean
performance goals to get the best results.
Evaluate how process changes might affect
wastewater volume or quality, or have other
environmental impacts. (For example, switching
from a water-based lubricant to an oil-based
lubricant or solvent could have implications for
worker health and the environment.)
Consider which water-efficiency best management
practices and technologies make sense for the
facility.
Adopt visual controls or mistake proof devices
on equipment (e.g., automatic shutoffs), and/or
procedures to help ensure that process changes
are effective and can be easily maintained.
After testing potential solutions, make changes and
evaluate actual performance and/or procedures
to help ensure that process changes are effective
and can be easily maintained.
After testing potential solutions, making changes,
and evaluating actual performance, be sure
to develop or update the standard work for the
activity so that employees can easily identify the
current, best way to perform an activity.

When evaluating water reuse opportunities, it is important


to consider both quality and quantity. Not all processes
need the cleanest, highest quality water. Many processes

22

BrewersAssociation.org

can reuse the waste water from one process as an input


to another process or use (e.g., air-handling condensate,
reverse osmosis reject water, etc.), provided the quality
of water needed for its intended use is matched. Testing
and additional treatment may be necessary to ensure it is
acceptable for future uses. When evaluating the feasibility
of using process water for irrigation or other outdoor uses,
check with the local utility or water pollution control agency
about restrictions on water reuse applications. The water
may require testing to ensure it meets pollutant limits.

Bells Brewery Focus On Water Reduction


The brewery consistently monitors water use


with the goal of decreasing water intensity. Submeters track water use in the brewhouse, cellar
and on both the bottling and kegging lines.
Engineering and procedural changes have also
helped reduce water usage.
The cellar CIP
(Clean-in-Place) system has
reduced the amount of water to clean the
brewerys tanks by about 65% over the previous
procedure.
A new filler vacuum pump design reduced water
that goes to drain from 57 liters per minute to 8
liters per minute, saving about 20 million pints of
water annually on their filling operation

Best practices can be found throughout the craft brewing


sector. These practices are presented according to the
different water-using areas in a brewery or brewpub. Within
each area, best practices are organized according to
the five strategies: adjust flow, adjust current equipment,
change to new equipment, reuse or recycle water and, last,
shift to a low-water or waterless process.

3.1 Brewing


In Section 2.0, a water survey helped to identify the main
users of water in the brewery. This survey can work as a
starting point for further identification of possible water
minimization measures.

Usage & Reduction Best Practices

Brewing Water And Wastewater Sources

Water to mills (process)

B1

Moisture in malt (process)

B2

Underfed water (process)

B3

Splurge water (process)

B4

Blending water (process)

B5

Water in syrup (process)

B6

Transfer water

B7

Running water

B8

Cleaning water

B9

Brewhouse

the generation of ideas and it will make people proud when


they can contribute to a more efficient brewery.

B10

Water in spent grain (waste)

B11

Evaporation

B12

Water in wort to cellars (process)

B13

Water in trub (waste)

B14

Wastewater

By using recent water and sewer billings together with any


sub-metering data, a water balance can be developed.
A water balance helps to:
Understand and manage water and effluent
efficiently
Identify areas with greatest cost saving potential
Detect leaks
Based on the water balance, a leak-detection checklist
can be used on a regular basis to determine possible hot
spots or areas where leaks can occur. A water balance
should be reviewed on at least a 12-month basis to ensure
all changes and adjustments to the process and equipment
are covered and the balance is up-to-date.

Some items that can be used for an employee awareness


program include:
A water ambassador or champion. He or she is the
main contact for all water-saving projects, measures
and metering. All employees know this person and
know where to go to in case of questions or ideas.
This water ambassador will also be responsible for
the regular leak surveys.
An incentive program. Employees are challenged
to bring in ideas for water- or effluent-saving
measures. For example, every three months the
employee with the best idea (e.g., highest water
saving potential, or most simple idea) is rewarded.
Employee education. Set up a toolbox meeting
on a regular basis to explain, discuss and educate
with the employees new findings, data and ideas
on water savings. This will enhance the involvement
and acceptance of any process adjustments, work
procedures or equipment changes.
Alignment with home usage. This will help the
employee understand the importance of water
minimization, as well as helping to put things in
perspective.
It is difficult to estimate the water savings possible with the
introduction of best practices, since each brewery may be
different from the next; however, there are some generally
accepted ranges of reductions as shown in the table below:
Typical Reductions In Water Use

Leak Detection Checklist


A systematic program of leak detection and repair
can prevent future water waste. On a regular basis,
thoroughly check the following areas:
restrooms and shower facilities (in-tank-type
toilets, conduct dye tests to locate hidden leaks)
kitchens, dishwashing facilities and foodpreparation areas
wash-down areas and janitor closets
water fountains
water lines and water delivery devices
process plumbing, including tank overflow valves
landscape irrigation systems

Increasing employee awareness will ensure that measures


taken to minimize the water use are understood and
accepted by the operators and other staff. It will enhance

Water saving measure

Possible application

Closed loop recycle

Fermentor cooling

Typical reduction in process use (%)

Cleaning-in-place (CIP)

New CIP set

60

Re-use of wash water

Cask washer

50

Countercurrent rinsing

CIP set

40

Good housekeeping

Hose pipes

30

Cleaning-in-place

Optimisation of CIP set

30

Spray/jet upgrades

Cask Washer

20

Brushes/squeegees

Fermentor cleaining

20

Automatic shut-off

Pump cooling water

15

>90

Best Practices - Mash Cooker, Lauter Tun, Boiling Kettle And


Whirlpool
The following best practices can minimize water use, effluent
flow and effluent strength.
Do not fill the mash or lauter tun too full. Train staff
to add the correct amount of liquor and investigate
the costs and possibilities of installing a meter to
measure the volume of liquor being added.
Water and Wastewater: Treatment/Volume Reduction Manual

23

If new batches are frequently brewed, store surplus


of wort and add it to the next brew.
Store residual wort with trub for possible sale to
farmers as animal feed supplement.
Do not mix residual wort with surplus yeast the
mixture will start fermenting and the value of both
waste streams will be reduced. Fermentable matter
needs to be kept separate to maintain its value as an
animal feed and yeast needs to be kept separate
to maintain its value for food manufacturers.
Separated grains and discharges to sewer will
have a high BOD concentration. Excess settleable
solids to sewer can cause blockage of pipes and
accumulate at manholes. Where possible, use dry
methods (brush or rake) to remove grains from the
mash tun. There is no need to use water jets and
subsequently discharge large amounts of effluent
to the drain. Fit fine mesh baskets in the floor drains
to collect and prevent grains from entering the
drainage system.

Heat Exchanger4

Make sure the heat exchangers are well maintained and


regularly check the meter readings of the water flow.
Pollution of the heat exchanger will negatively affect the
heat transfer and cause an excess of water flow.

Float Operated Valves


New valve pays back in less than five months
Fitting a float-operated valve at a low level in the hot
liquor tank at J W Lees & Cos Manchester brewery
minimised both the overflow of hot liquor to drain and
the quality of cold top-up liquor required. The one-off
cost of the alterations was 2000 for the valve, plus
minor modifications to the tank and pipework. The
savings in water, evergy and trade effluent charges
are worth 5000/year.

Best Practices - Heat Exchangers


Compact heat exchangers are used in almost all breweries
to recover heat from hot wort. The recovered energy can
be used to pre-heat subsequent mash water or for washing
purposes.
Since fermentation temperatures and cold liquor
temperatures may vary among the different brews,
automatic temperature control will allow for flow optimization
of wort and cold liquor and will minimize water use.

24

BrewersAssociation.org

Check to ensure cold liquor is not excessively warmed by


ambient conditions.
It is important to check the heat exchanger capacities and
the settings of the top-up valves, to prevent hot liquor tank
overflows.
Best Practices Fermentation Vessels
Single pass cooling of fermenters uses vast amounts of water.
It is generally found at sites with inexpensive and readily
available water (borehole or river extraction) and permission
to discharge the cooling water to another location other
than the sewer.
Closed loop systems will have pumps and control systems
in place to regulate the cooling water flow through the
fermenters cooling system. Make sure the pump size is
adequate to cope with the maximum flow of cooling water
when all fermenters are in use. Also, prevent overflow by
setting the top-up level in the chilled water tank so that it is
not topped-up until the reception tank is full. Install frequency
controllers on the pump to fine-tune the water flow based
on cooling needs. This will help to minimize the water flow as

Usage & Reduction Best Practices

well as reduce energy use. Ensure procedures are in place


to stop the cooling water supply when the fermentation
process comes to an end.
Fermentation Water and Wastewater

Water from brewhouse (process)

B12

Water in yeast (process)

C1

Cooling water

C2

Backwash water

C3

Precool water

C4

Brewing water (process)

C5

Transfer water

C6

Cleaning water

C7

Best Practices - Yeast Disposal


When the beer is drawn off, a yeast slurry remains for
removal. Avoid disposing this slurry to the drain, as it has a
high BOD value and high suspended solids content. Also,
large quantities of yeast lead to organic acids formation,
affecting the pH (making the effluent more acidic).

Removing Sources of High BOD Demand

Cellars

C8

Water in beer to packaging (process)

C9

Evaporation

C10

Wastewater

Since open fermenters typically require manual cleaning,


some measures can be taken to optimize the cleaning of
the vessels and minimize the water use, as well as lower the
effluent strength (fermenters can be the source of almost
half of the BOD content and almost 70% of the suspended
soils content of a typical brewery).
Yeast and tannins tend to stick on the wall of the fermenters,
resulting in high water use for removal. Products are
available to make the manual cleaning of the fermenters
easier, thereby reducing cleaning times and water use.
Detergent sprays are available for more effective removal
of deposits. The foam is used to soften the deposits (after an
initial rinse) with a minimum of water. Only a small amount
of water is needed afterwards to remove the foam. Foam
canisters can be obtained through many detergent suppliers.
Use of scrapers and brushes will reduce the time needed
to clean the vessel with a hose. Avoid disposing of large
amounts of peracetic acid (for tool sterilization) to the
drain and try to eliminate the need for rinsing by storing the
sterilized tools in dilute propionic acid. This will reduce the
effluent strength.

Farmers save brewery money by taking away surplus


yeast and other wastes
Ringwood Brewery stores surplus yeast in a former
fermenter vessel. Weak wort, trub, ullage and spoilt
beer are stored together in another vessel. The
4900-litre (30 barrel) tanks cost 400 each and another
500 to install them both on steel supports. The tanks
are emptied free of charge by local farmers. The
savings in trade effluent charges to the Brewery are
worth approximately 3000/year, giving a payback
period of just over five months.

An alternative may be to pass the slurry through a filter press


or centrifuge to recover residual beer that may be reuse in
the process. The remains may be disposed separately or sold
as animal feed additives. Yeast contains over 40% protein
and can be suitable as an animal feed supplement. If no
filtration is possible or the residual beer cannot be reuse, the
complete slurry may be sold as well as animal feed and the
liquid waste can be disposed to the drain.
Best Practices - Filtration
Diatomaceous earth, plate and frame, or rotary filters
have traditionally been used to filter the beer prior to
packaging; however, water consumption is high with these
technologies. Alternatives include cross-flow or membrane
filtration. Cross-flow filtration involves circulating the beer
though a microfiltration cartridge containing a ceramic
membrane. Yeast, bacteria, and other solids are retained
on the membrane. This produces a thick yeast slurry that
can be disposed as described above. Since all bacteria are
removed, no further pasteurization is needed.

Water and Wastewater: Treatment/Volume Reduction Manual

25

Best Practices - CIP system


Using a CIP system is generally more efficient than manual
cleaning. The advantages include:


Increased vessel cleanliness due to chemicals and


high temperatures employed
High level of automation possible
Reduced water and chemical consumption

CIP is not a novel technology, yet it is often considered as


such. There is significant opportunity to improve CIP, which
offers water, cost and environmental savings.

Steps to Reducing CIP Water




Eliminate a CIP Program Step


Reduce intermediate and final rinse times
Reuse cleaning and rinsing water

If CIP is not possible, a high-pressure hose will use much less


water than a standard hose.

Definition of CIP
The Society of Dairy Technology defines CIP as: The
cleaning of complete items of plant or pipeline circuits
without dismantling or opening of the equipment and
with little or no manual involvement on the part of the
operator. The process involves the jetting or spraying of
the surfaces or circulation of cleaning solutions under
conditions of increased turbulence and flow velocity.

The table shows a comparison of water and detergent use


by various cleaning methods for a 3,000-liter vessel with
identical cleaning parameters for each method. The figures
demonstrate the increased resource efficiency from full reuse automated CIP.

26

BrewersAssociation.org

Advantage of a CIP system


SYSTEM

WATER (LITERS)

DETERGENT (LITERS)

Boil out system

6,500

45

Total loss

3,000

30

Single use

1,200

Partial reuse

1,100

Full reuse

600

Simple CIP systems can be retrofitted into an existing


plant, though this can be more costly and difficult than
consideration at the plant design stage.
Simple systems use the vessel to be cleaned as a detergent
reservoir. The most complex systems are multi-channel with
tanks for detergent, pre and post rinses and sometimes
disinfectant.
With complexity comes ease of operation, repeatability and
reduced running costs at the expense of higher installation
charges and reduced flexibility in terms of the ability to
adapt to plant or product changes.
It may be possible to reuse the water and detergents from
different washing operations to clean the mash tun. For
example, detergents used to clean the fermenter could
be stored and subsequently transferred to the mash tun.
After cleaning the mash tun, the same detergent could be
reused to clean the copper.
A water tank can be installed so that the final rinse water
can be recycled to the pre-rinse stage. To prevent overflows
from the recovered water tank, make sure the volume of
the water used in the final rinse and the pre-rinse roughly
balances.
Recover and reuse detergents or caustic several times.
pH measurements can be used to determine the strength
of the chemical solution. In automated controlled CIP
sets, the amount and types of usage can be determined
automatically. When recovering water, consider the volume
in the pipework when determining the switch-over time

Usage & Reduction Best Practices

between CIP tanks. Incorrect settings can allow first rinse


water to enter the final rinse water tank.

them more difficult to clean. The graphics shows examples


of good and poor designs.

Since an automated controlled CIP set often only has a


limited number of programs, take into account the vessel size
and shape when adjusting the CIP programs. The potential
content of the vessels and the distance of the vessels from
the CIP set (volume in pipework) are also relevant.

Best Practices - Chase Water

CIP Tanks5

When beer is transferred in pipes, the pipes have to be


cleaned and rinsed often. The operator needs to decide,
in the case where pipes are rinsed with water, when the
cleaning is ready and when the pipes can be filled with
beer again. This process relies heavily on the judgment
of the operator, which can lead to more water use than
necessary. Automated interface detection systems
may help, but tend to be unreliable. Purging with CO2 is
an option, but not often done because of the pressure
involved and leaking of CO2.
Another method is using a pigging system. This is an
engineered plug or ball which fits inside the pipe and is pushed
through the pipe either mechanically or hydraulically to clear
material ahead of the pig. This can only be used where bends
have a long radius and valves have bore openings.

3.2 Packaging

Best Practices - Vacuum Pumps


Many vacuum pumps use water for cooling and for forming
the seal (a liquid ring). Instead of using water on a oncethrough basis, it can be recovered for reuse, by recirculating
the seal water via chillers or cooling tower.

Traditionally, canning and bottling lines have used water as


a lubricant to reduce friction on conveyer belts and reduce
static between cans or bottles, with water sprayed directly
onto the lines through jets. Opportunities to save water
include:


If a closed-loop system is not possible, consider using the
water as rinse water in the cask or bottle washer.

Best Practices - Good Process Design


It is good practice to design equipment with fewer parts
and no points where fluid accumulates and that detergent
cannot reach. This will reduce cleaning time as well as save
water, chemicals and energy. Also, the design of pipes and
drains can influence the accumulation of solids, making

Good maintenance of the conveyer belt system


can reduce water consumption of a water-based
lubrication system by up to 45%.
Change from water spray lubrication to a dry-lube
system.
Deploy plastic belts instead of standard steel belts.
Large amounts of water are also lost if the water
continues to spray when the conveyor belts stop.
Fitting a solenoid valve to isolate the flow when the
conveyor is switched off is a low-cost measure that
can produce large savings in water use and effluent
costs.
Optimize conveyor rinse jet pressures. Replace
nozzles to increase the pressure and nozzle diameter.

Water and Wastewater: Treatment/Volume Reduction Manual

27

Poor and Good Design Examples


Solenoid Valve Case Study
Examples of poor design

Examples of good design

A soft drink producer installed solenoid valves on a


conveyor system and adjusted the spraying nozzles
(from 2 mm to 0. 2-0. 3 mm). Implementation of these
measures allowed water savings of:

Drainage of pipelines

26,697 kl per year for the installation of solenoid


valves
29,160 kl per year for the optimization of nozzles
and jet pressures

Packaging Water And Wastewater


Drainage of vessels

Water from cellars (process)

C8

Transfer water

P1

Rinsing water

P2

Cullet flush water

P3

Vacuum pump water

P4

Pasteurizer make-up water

P5

Cooling tower make-up water

P6

Water in chain lube

P7

Cleaning water

P8

Washdown water

P9

Welded joints

Bolt Caps

Packaging

P10

Water in packed product (process)

P11

Wastewater

P12

Beer loss

Solenoid valves
A solenoid valve is an electromechanically operated valve.
The valve is controlled by an electric current through a
solenoid: in the case of a two-port valve the flow is switched
on or off; in the case of a three-port valve, the outflow is
switched between the two outlet ports. Multiple solenoid
valves can be placed together on a manifold.
Solenoid valves are the most frequently used control
elements in fluidics. Their tasks are to shut off, release, dose,
distribute or mix fluids. They are found in many application
areas. Solenoids offer fast and safe switching, high reliability,
long service life, good medium compatibility of the materials
used, low control power and compact design.

28

BrewersAssociation.org

Best Practices - Cask and Keg Washing


Disposal of spent beer remaining in returned packages
should be conducted before cask and keg washing. This
spent beer represents a high BOD source to sewer. The
removal and storage of spent beer with other high strength
liquids should be considered.
A second, more general measure for cask and keg washers is
the effective design of the spray nozzles. High-efficiency spray
nozzles use water at a lower pressure and the improved spraying
action ensures better water contact with the cask. To reduce
the risk of nozzle damage for moving beam washers, make the
cask position as reliable as possible. For manually handled cask
movers, simplify the procedures and make employees aware of
the risk. Check the nozzles regularly and repair or replace them
immediately to avoid inadequate cleaning.

Usage & Reduction Best Practices

Improved Cask Washing Process

Best Practices - Cask and Keg Filling

Major savings with improved cask washing process

Beer lost at the filling stage is expensive in terms of lost product,


wasted labor, energy, water and raw ingredient inputs and
effluent charges. Meter the volume of beer used to fill the
casks, rather than trust capacity fills. This reduces the need to
rely on the internal return system. This backflow system avoids
the loss of beer due to foaming or over-filling of the casks.

Bass Brewers knew that the cask washing plant at its


Burton C Brewery used water inefficiently. A quality
improvement team formed to evaluate the washing
process identified three areas where major savings
could be achieved, i.e.:

Bottle Rinser6


redesign the spray nozzles to give more effective


water contact with the cask;
ullage collection and sieving;
recovery of final rinsewater and re-use for
the external rinse, oil cooking and conveyor
washing stages.

These and other modifications produced cost savings


of 86 900/year and reduced water consumption by
about 43 000 m3/year. Total project costs were 95
350, giving a payback period of only 13 months.
Full details of this project are given in Good Practice
Case Study (GC21) Improved Cask Washing Plant
Makes Large Savings, available free of charge
through the Environmental Helpline on freephone
0800 585794.

A third consideration is the recovery of final rinse water.


This water can be re-used for the external rinse or for
the pre-rinse of the cask. If that is not possible, the final
rinse water may be used for cooling applications or for
conveyor belt washing.
The use of detergents can cause an extended final rinse.
It can be evaluated (water versus energy use) to minimize
the detergent concentration and perhaps increase the
temperatures or make the hot rinse longer.
Another effective method for water reduction is to adjust
working procedures to optimize cask cleaning relative to
the cask size. For automated cask washers, the automation
needs to be adjusted.
For small, manual cask washers, the timing between the
rinse stages in valve settings can be adjusted to take into
account the volume of water remaining in the pipes.

Best Practices - Glass Bottle Washing and Pasteurizing


Much of the waste from bottle washers and pasteurizers
is due to the overfilling of the feed tanks at the base of the
units. This can be caused by leaks or by faulty valves or simply
by an excessive top-up rate. In many washers or pasteurizers,
the overflow points cannot be seen by the operators and
overfilling of the feed tanks goes without notice. Ensure
overflow points are visible for operators by extending the
pipe to a position where operators can see it. Water metering
will also allow identification of water use during periods the
machines are not operating.
Consider the re-use of the final rinse water of the washers for
the pre-rinse stage (or any other stage or application). For
single-use bottles, the rinse water used before the filling can
be reused for many applications; however, as it may contain
glass fragments, it should not be reused if there is a risk of
contaminating the product.
Optimize the caustic dosing to the minimum quality
standards to allow minimum water use during rinsing. Finally,
it is a good idea to inspect the valves and the pipes of the
washers and the pasteurizers regularly to detect leaks.

Water and Wastewater: Treatment/Volume Reduction Manual

29

Bottle Washer Case Study


Water recycling was implemented on a bottle washer
for a system with a pre-rinse followed by three caustic
and three water sections. The solution in the first
caustic section of this system is filtered and recycled
to this first section. In the third caustic (spray) section,
an air fan was installed, to minimize the carryover of
caustic to the warm water sections.
In the last rinsing section, rinsing was previously
performed with three nozzles for the inside and one
for the outside of the bottle. The rinsing at this line was
modified to two inside spray nozzles operating with
7 kl/h fresh water. This rinse water is then collected,
treated and used for one inside rinse and one outside
rinse nozzle (overall, 7 kl/h). This rinse water is again
collected and reused:



first for a cold water bath


second for a cold water rinse
third for a warm water rinse
finally for the pre-rinsing of the bottles

The treatment of the rinse water consists of a buffer


tank, two parallel membrane filters of 5 m and
disinfection by UV lamps.
The fresh rinse water flow is adjusted according to
the running of the bottle washer, presence of bottles,
bottle speed, water level and temperature.
These measures resulted in a decrease of the specific
water consumption (bottles of 1 and 1. 5 l) from 0. 6
to 0. 4- 0. 5 l/bottle. The total fresh water consumption
decreased from 39,590 to 23,960 kl/year and is equal
to a water reduction of 39%.

3.3 Warehousing


Not much water is used in the warehouse, with most being
used only for cleaning purposes. Consider using water from
final rinses or other clean streams from the brewery process
for this application.
Make people aware of water wasting, as described earlier,
and optimize the hoses used. In many cases, high pressure
hoses, which use less water, can be used effectively in
warehouse areas.

30

BrewersAssociation.org

3.4 Support Systems (Utilities)




Support systems include all utility and powerhouse
operations. Often, water used for sanitary needs and
outdoor landscaping is included in this category.
Best Practices - Cooling Towers
Evaporative cooling is a common and efficient way of
dissipating thermal loads. Cooling towers and evaporative
condensers require significant quantities of make-up water
to compensate for losses associated with evaporation, drift
(or mist) and blowdown (or purge).
A key parameter used to evaluate cooling tower operation
is cycles of concentration (sometimes referred to as cycles
or concentration ratio). This is calculated as the ratio of the
concentration of dissolved solids (or conductivity) in the
blowdown water compared to the make-up water.
Cooling Towers7

Usage & Reduction Best Practices

Water use can be minimized by:


Maximizing
the
cycles
of
concentration.
Many systems operate at two to four cycles of
concentration, while six cycles or more may be
possible. Increasing the cycles from three to six will
reduce cooling tower make-up water by 20%, and
cooling tower blowdown by 50%
Undertaking routine surveys of cooling towers and
evaporative condensers for leaks and losses, and
taking remedial action as soon as possible
Repairing or replacing poorly operating blowdown
valves promptly
Checking overflows (e.g., make-up water tank) and
ensuring they are not overflowing

condensate for re-use will reduce water use,


chemical use and energy consumption.
Best Practices - Compressors
Refrigeration compressors often need cooling water. Since
they produce excessive noise, these compressors tend to be
isolated and only inspected when needed.
Compressor8

Best Practices Steam Generation


Boilers and steam generators consume varying amounts of
water depending on the size of the system, the amount of
steam used, and the amount of condensate returned.
Boilers9

If possible, consider changing to a closed-loop system with


a cooling tower, or otherwise, integrate the compressor
cooling with another chilled water loop, like fermenting
cooling. This chilled water loop is particularly effective when
the brewery has several water cooled units. A small bleed
will be needed for hygiene reasons.

The key to operating an efficient steam boiler is to maximize


steam generation and minimize losses to sewer by:
Inspecting the boiler, condensate system and steam
traps to find and promptly repair leaks.
Properly insulating steam and condensate pipes and
hot well to decrease steam requirements and heat
loss.
Minimizing blowdown volumes by ensuring water
treatment is optimized and blowdown automated.
Ensuring condensate return is maximized and
the system is working effectively. Recovering

If a closed-loop system is not possible, there may be a


potential to reuse the water for various washing operations
described earlier, like a cask washer or the CIP system.
In this case, connect a solenoid valve to the cooling
water supply to automatically cut off the supply when
the compressor stops. Also install a frequency control to
the pump of the cooling water supply to prevent manual
tampering of the flow.

Air-Cooled Compressors
When replacing a water-cooled compressor, consider
the use of an air-cooled unit to save water and during

Water and Wastewater: Treatment/Volume Reduction Manual

31

cool ambient conditions, it may save energy as well.

Some (tank) radiators tend to accumulate ice due to


humidity in the area. Do not use water to remove this ice. It
will need an excessive amount of water and will increase the
humidity even more. It is more efficient to use excessive heat
or hot water or, in low peak hours, use electrical heating.

of measures.

Sierra Nevada Brewing Company Taproom Water


Saving Projects

3.5 Food Service



Many craft breweries include a brewpub within their


operational footprint. In these instances, water and
wastewater issues associated with food and drink services
must be addressed. There have been a number of best
practices identified for saving water in food service
establishments. The National Restaurant Association has
developed the Conserve Sustainability Education Program.
It is an excellent online resource to help restaurants reduce
operating expenses and leave a lighter footprint on the
environment. Many of the ideas presented in this section are
from the Conserve program.
Also check with your local water supplier for free water audits
or rebates and incentives for restaurant water savings.

Top Water-Saving Opportunities For Restaurants/


Brewpub




Metering (control and predict your water use)


Retrofit
Use low-flow pre-rinse spray valves, faucets, toilets
and urinals
Add aerators
Add insulation

Water is a significant part of restaurant operations. It is


used for cooking, cleaning, food production, customer
consumption, and sometimes for landscaping. Conserving
hot water is always a smart idea, because it trims two bills:
water and the electricity or natural gas used to heat it.
A brewpub can be split into the kitchen area, the dining
and restroom area and the outside of the brewpub
(landscaping). Similar as with the brewing process, it all starts
with some generic measures, like employee awareness and
understanding water use.
Training employees on water usage and how they can
contribute will help the understanding and acceptance
32

BrewersAssociation.org

Replace Bathroom Faucet Aerators - 789,983


liters/year (immediate payback)
Retrofit flush valve toilets w/ dual flush handles
288,811 liters/year (0. 7-year payback)
Install Air-Cooled Ice Machine 3,159,930 liters/
year (1. 5-year payback)
Replace Pre-Rinse Spray Valves 988,186 liters/
year (immediate payback)

Best Practices - Dishwashing


When cleaning dishes and plates, avoid using running
water to thaw or rinse food. Instead, gradually thaw frozen
food in a refrigerator. Wash vegetables in ponded water;
do not let water run in preparation sink. Train employees to
immediately scrape & wipe plates.
Use squeegee scrapers and avoid rags which soak water.
Soak dirty pots and pans instead of rinsing them in running
water. Pre-soak with sustainable cleansers, using baking
soda to pre-soak pots and vinegar to cut grease.

Dishwasher Tips








Run fully loaded dish racks


Pay attention to the pressure gauge only 20 psi
needed
If conveyor-style dishwasher, make sure its in
auto mode
Turn off at night and when idle for long periods
of time
Add or maintain wash curtains
Repair leaks
Replace worn spray heads
Soak heavily soiled dishes
Use heat exchangers (usually called an indirect
exchanger its a plate heat exchanger so that
the wastewater doesnt come in contact with
incoming water)
Check that water temperatures are between 120
to 130 degrees and the booster heater is used
to reach 180 degrees if the dishwasher is hightemperature.

Usage & Reduction Best Practices

Check with the manufacturer to see if dishwasher spray


heads can be replaced with more efficient heads or if flow
regulators can be installed without voiding manufacturer
sanitation warranty. Replace existing spray valves with
efficient, high-velocity models.
Reduce the water volume in the dishwasher by use of a
pressure regulator. A good practice includes installing
manual triggers on all sink spray hoses so that water is used
on demand only.
When manually washing dishes, use the three compartment
sink for dipping dishes and equipment, instead of using
running water.
In conveyer type washers, ensure that water flow stops when
there are no dishes in the washer. Install a sensing arm or
ware gate that will detect the presence of dishes and shut
off water when there are no dishes on the conveyor. Some
machines are designed to dispense water if the conveyor
moves, whether it is carrying dishes or not. If this is a problem,
install an electronic eye sensor system, which will turn on
water only when dishes are moving on the conveyor belt.
Install spray valves that uses less than 6. 1 liters per minute.
Efficient pre-rinse spray valves do as good of a job as
older, less efficient models, but use a fraction of the water.
Savings depend on the flow rating of the existing unit, the
water pressure at your facility, and the flow rating of a new
efficient model. This may be the most cost effective energy
and water saving initiative for the brewpub.
Best Practices Refrigeration
Refrigeration in the kitchen includes coolers, chillers and ice

machines. Water-cooled ice machines and refrigeration


equipment should be replaced with air-cooled units or units
that are cooled with a closed loop of water.
Icemakers use water in two ways: for cooling the machine
and for freezing water into ice. Water-cooled ice machines
producing 363 kilograms of ice per day and running at 75%
capacity will consume about 3,400 liters of water a day just for
cooling. That amounts to over one million liters a year. As for
the ice-making process itself, there is a wide range of water
consumption depending on the manufacturer and type of
machine.
Ice cube makers use the most water, typically 76-95 liters
to produce 45 kilograms of ice cubes. Some machines use
considerably more, up to 341 liters of water per 45 kilograms
of ice. Machines that make ice flakes, on the other hand,
consume far less, about 57-76 liters of water to produce 45
kilograms of ice.
Best Practices - Grease Traps
The installation of grease traps will help to minimize grease
and other contamination going to the sewer. In addition to
often being required by city ordinance, it will also help to
reduce effluent strength. If a surcharge is being paid to the
sewer authority for BOD, the removal of grease can help to
lower these fees.
Best Practices Dining Area
Implement a water conservation policy for food servers.
Serve water in bars and restaurants only upon request to
reduce wash and ice loads. Provide information at each
table regarding the reasons for such measures. Automatic

Grease Trap Operation

Coagulated grease and oil are lighter


than water and will rise to the surface .

Inlet

Outlet

Heavier food scraps settle


to the bottom of the trap .

Degreased water in the middle of


the tank passes through the sewer .

Water and Wastewater: Treatment/Volume Reduction Manual

33

water service is a practice of the past. Not every guest wants


or will drink the glass of water. Changing this practice is as
simple as asking, Would you like a glass of water? When
you reduce the number of glasses of water served, youll
not only reduce the amount of water that would have filled
the glass, but youll also conserve ice, water used to wash
the water glasses, straws, lemons (if you garnish water in your
establishment), beverage napkins, and/or coasters.
Let sales volume determine batch sizes needed for
beverages. If you brew coffee or tea or make specialty
beverages, such as flavored teas or lemonade, determining
whether a full or half batch is required will help you save
water and product.
Determine whether a glass tender or the triple sink method
for washing bar glasses best suits your establishment. If using
a glass tender:
Make sure it is not running continuously
Wash glasses only when you have enough for a
complete cycle (except at closing when all glasses
need to be cleaned)

High-Efficiency Toilets (HET)



Use ice properly. Reduce the amount of standing ice in
your bin throughout the day so that very little remains at
close. This way, you will use very little hot water to melt what
remains. One technique used in the industry is to scoop the
ice out of the bin into a bus tub. The ice from the bus tub is
then emptied onto the landscaping. Very little water is then
needed to clean and sanitize ice bins.
Best Practices - Restrooms
Many restroom faucets use 9.5 to 19 liters per minute. Lowflow faucets are affordable and can reduce the flow to less
than 5.7 liters per minute.
Post signs in restrooms/lavatories to remind customers and
staff to not dispose any non-flushable items in toilet. Any
material other than toilet paper will force the septic tank to
use more water to flush the material down the drain.
Replace existing toilets and urinals with plumbing-codeconforming high-efficiency toilet (HET) or ultra-low flush (ULF)
models. Provide additional urinals in mens restrooms and
reduce the number of toilets.

34

BrewersAssociation.org

High-efficiency toilets flush at 20% below the 6.1


liters-per-flush (lpf) U. S. maximum or less, equating
to a maximum of 4.85-lpf. (The HET category
includes dual-flush toilets.) The average water
savings for HETs is estimated to be 144 liters per
day (lpd) when replacing a non-ULFT and 26 lpd
when replacing a ULFT.
High-efficiency urinals (HEU) operate at 1.9 lpf
or less. (The HEU category includes non-water
urinals) Based on data from actual usage, these
urinals save 75,708 liters of water per year with
an estimated 20-year life. In addition to saving
water and sewer costs, non-water urinals are
an improvement over traditional urinals in both
maintenance and hygiene.
Ultra-low-flush toilets (ULF) use no more than 6.1
lpf, rather than 13.2 to 26.5 liters of water used by
older designs. The required minimum was set to
6.1 lpf in 1997 for commercial use.
Waterless/No-Flush Urinals work completely
without water or flush valves. They save up to
170,343 liters of water per year per urinal.

Use low-flow aerators. Aerators should use 1.9 - 3.8 liters


per minute. Hand-washing sinks that are used infrequently
will have a longer wait time for hot water as a result. Lowflow models should never be used where containers are
filled. The time it takes to fill containers is increased, thus
increasing labor costs, and there is no significant energy
or water savings. Nationally, there is no specific pressure
for hand-washing sinks, but the flow of hot water for the
sanitizing rinse in a dishwasher must not be less than 7
kilograms per square inch. However, there may be city/
county/building plumbing codes that have different
minimum water pressure requirements.
Best Practices Parking Lot/Landscape
Use of water for outdoor activities, such as cleanup or
landscaping can have a significant impact on costs. Most

Usage & Reduction Best Practices

breweries pay sewer charges based on a percentage of


incoming water usage. Excessive use of water for outdoor
activities will result in higher water and sewer charges. This
can be alleviated by negotiating the percentage with the
authority or by installing a separate meter on water used for
outdoor purposes.
Landscaping should be planned with drought-resistant
and native plants where possible. Native plants require less
water, and are better adapted to existing soil, climate, and
wildlife. Cluster plants by similar irrigation needs.

Turf Grass
Minimize the use of lawn or turf grasses. These
choices require significant watering to maintain
their appearance, regular mowing and topical
amendments, such as fertilizer and herbicides,
which can cause harmful runoff. Use ground cover
or mulch around landscape plants to prevent
evaporation. Mulch helps keep soil moist and
retards the growth of weeds.

Develop a rain water catchment system (i.e., rain barrel)


and reuse this water for landscaping or for instance for truck
washing as well. Watering should be conducted early in the
morning or in the evening when wind and evaporation are
lowest. Apply water, fertilizer, or pesticides to landscape only
when needed rather than on an automatic schedule. Be
sure all hoses have shutoff nozzles.
Often sidewalks and decks are overcleaned. Therefore,
scrub and/or power wash these surfaces only when
needed. Also, use a broom to sweep away debris before
washing. Hoses use large amounts of water, so reducing the
use greatly reduces the amount of water.

3.6 Concerts/Events


The concert venue and the selected caterer/concessionaire
may be able to offer and highlight its commitment to using
water responsibly. Reducing or eliminating the need for
bottled water is a key to not just reducing waste from plastic
bottles, but to also reduce the water footprint needed
for the manufacturing process of the bottles. Check with
the local water utility if they support concerts and events
through a potable water truck. For example, in the Denver
area, the local utility has a water truck for use for community
events and concerts.
Select venues and concert promoters that are responsible
with their water footprint and wastewater discharge. Planet
Bluegrass, a festival and concert producer in Colorado,
performed several eco-audits and examined their energy
and water usage. As a result, they now use low-flow faucets
and are investigating dual-flush toilets in many of their
venues.

Case StudyGillette Stadium, Foxborough, MA.


The stadium that serves as the home of the New
England Patriots, as well as numerous soccer matches,
concerts and other public events has the distinction
of having one of the largest recreational water reuse
systems. When the Town of Foxborough advised the
private developers that constructed the stadium
that they could not furnish enough water or treat the
wastewater from the planned 68,000-seat stadium, it
became apparent that the reuse of reclaimed water
was the only answer.

Xeriscaping
Xeriscape can be defined as water-efficient
landscaping appropriate to the natural environment.
The goal of a xeriscape is to create a visually attractive
landscape that uses plants selected for their water
efficiency. Properly designed and maintained, a
xeriscape can use less than one half the water of a
traditional turf-dominated landscape.

Water and Wastewater: Treatment/Volume Reduction Manual

35

section four
Onsite Wastewater Treatment
In the previous section, best practices that lower water use
and thus incoming water costs are outlined. A reduction in
water usage will help lower wastewater costs when charges
are based on the amount of incoming water.

Onsite pre-treatment can reduce the amount of solids and


organics sent offsite for treatment. It usually does not treat
any sanitary waste, since that may be discharged through
a separate sewer system.

Best practice reduction measures were discussed as well


as ways to lower the strength of effluent. Since surcharges
are applied based on this effluent strength, these measures
make sense to implement.

Effluent pre-treatment systems reduce effluent loads


using either aerobic or anaerobic methods. Both require
large holding tanks, de-sludge operations, and sensitive
controls and/or operating conditions. In the dynamic field
of wastewater pre-treatment, increasing numbers of new
systems are being trialed at food and beverage facilities.

The remaining effluent volume and strength is typically


discharged by most craft brewers through a public sewer
system to a municipal or private treatment system. Some
brewers have installed onsite pre-treatment systems before
discharge to a municipal treatment system. This decision is
typically based on regulatory compliance or economics.
It is also highly dependent upon land space available at
the brewery site. Most pre-treatment units require a large
footprint that may not be available to space limited sites.

When Should You Consider Advanced Treatment?


Some smaller brewers have been forced to install
advanced pre-treatment units to meet local
regulatory requirements. In general, advanced
systems do not have an economic payback until
there are some economies of scale associated with
larger volumes of wastewater. As a rule of thumb,
consider advanced wastewater pre-treatment when
annual sewer discharge costs approach, or are
greater than, $250,000. This cost equates to a brewery
size of 150,000 300,000 bbl/year based on flows of
2-4 bbl wastewater/bbl beer. This assumes sewer
surcharge rates of $0.30/lb BOD, TSS.

36

BrewersAssociation.org

There are three primary pre-treatment processes utilized at


breweries:
pH neutralization
Solids removal
biological treatment
Regulatory limits usually dictate the need to install pH
neutralization. Solids removal is typically driven by regulatory
or cost savings requirements. Biological treatment normally
is driven by cost savings; however there are situations where
a municipality requires some form of organic pre-treatment.

4.1 pH Neutralization


Adjusting the pH in a waste stream can be one of the
most difficult processes in wastewater treatment. Good pH
neutralization and adjustment includes proper mixing, tank
configuration, and instrument control.
Brewery wastewater can contain slugs of materials that can
be very low in pH or very high, depending upon the timing of
acid or caustic usage. Over a longer period of time, brewery
pH may be closer to neutral. However, municipal treatment

Onsite Wastewater Treatment

ordinances typically regulate pH to protect workers that


may be doing maintenance on sewer lines, the integrity
of the sewer lines, and to protect aerobic bacteria in their
biological treatment systems.
Typical pH Neutralization
Sodium
Hydroxide

Sodium
Hydroxide

Sulfuric
Acid

EFFLUENT

INFLUENT

Mix Tank

Trim Tank

Two key components of these systems include the following:


Flow equalization is a technique used to consolidate
wastewater effluent in holding tanks for equalizing
temperature or pH before introducing wastewater
into downstream treatment processes.
Chemical adjustment of brewery pH and
flocculation of solids are the most common pretreatment techniques used at breweries. The
acidity or alkalinity of wastewater affects both
wastewater treatment and the environment.
Brewery wastewater tends to gravitate towards a
higher pH due to the amount of caustic used for
cleaning. Low pH indicates increasing acidity while
a high pH indicates increasing alkalinity (a pH of 7
is neutral).

Small Brewer pH Neutralization Example


The Lone Tree Brewing Company in Colorado installed
a simple 500-gallon plastic tank for pH equalization.
This allows the discharge to the municipal plant to be
more consistent by leveling high and low pH swings
from cleaning operations.

4.2 Solids Removal




Brewers that install pH pre-treatment facilities or those
that cannot meet regulatory restrictions for solids may
install onsite solids removal systems. These systems can be
categorized as follows:
Physical treatment is for removing coarse solids
and other large materials, rather than dissolved
pollutants. This may be a passive process, such as
sedimentation to allow suspended pollutants to
settle out or float to the top naturally.
Screening is typically a first step to remove glass,
labels, and bottle caps, floating plastic items and
spent grains.
After the wastewater has been screened, it may
flow into a grit chamber where sand, grit, and small
stones settle to the bottom.
With the screening completed and the grit removed,
wastewater still contains dissolved organic and
inorganic constituents along with suspended solids.
The suspended solids consist of minute particles of
matter that can be removed from the wastewater
with further treatment, such as sedimentation or
chemical flocculation. Flocculation is the stirring or
agitation of chemically-treated water to induce
coagulation. Flocculation enhances sedimentation
performance by increasing particle size, resulting in
increased settling rates.

4.3 Biological Treatment




After the brewery wastewater has undergone physical
and chemical treatment, it can be biologically treated.
Biological treatment of wastewater can be either aerobic
(with air/oxygen supply) or anaerobic (without oxygen).
Generally, municipalities have relied upon aerobic systems
for the treatment of brewery wastewater. Recently,
anaerobic systems have become a more attractive option
since biogas can be generated for energy use.

Water and Wastewater: Treatment/Volume Reduction Manual

37

Anaerobic wastewater treatment is the biological treatment


of wastewater without the use of air or elemental oxygen.
Anaerobic treatment is characterized by biological conversion
of organic compounds by anaerobic microorganisms into
biogas. Biogas is mainly methane (55-75 vol%) and carbon
dioxide (25-40 vol%) with traces of hydrogen sulfide.
Anaerobic Treatment in the Brewing Industry
Suited for brewery wastewater
Generally soluble organics and medium to high strength
Produces low amounts of sludge
Requires small amounts of chemicals
Produces valuable biogas and sludge
It is a tried & true technology
Smallest entry-level anaerobic system
The smallest is a 50 kl UASB system
Equivalent to a brewery size of between 118,000
236,000 bbl per year production
Installed cost: $700,000 - $1,200,000 U.S.
Aerobic biological treatment is performed in the presence of
oxygen by aerobic microorganisms (principally bacteria) that
metabolize the organic matter in the wastewater, thereby
producing more microorganisms and inorganic end products.
Aerobic treatment utilizes biological treatment processes,
in which microorganisms convert non-settleable solids to
settleable solids. Sedimentation typically follows, allowing
the settleable solids to settle out.
Aerobic Treatment System10

Practically speaking, the smallest aerobic system


will be sized to treat 37,854 lpd
Equivalent to a brewery size of between 17,000 33,000 bbl per year production
Installed cost: $400,000 - $900,000 U.S.

Pre-treatment of brewery wastewater will reduce the


effluent strength as an end-of-pipe solution. Both aerobic
and anaerobic treatment options are available. There are
differences, advantages and disadvantages of these two
systems.
Comparison Of Two Pre-Treatment Options
CONS

AEROBIC TREATMENT

ANAEROBIC TREATMENT

Higher energy use

80+% COD reduction

Generates biomass
(sludge) requiring disposal
High operating costs
Larger Footprint
PROS

99+% BOD reduction

Provides renewable energy


(biogas) and low biomass
Low operating costs
Smaller Footprint
Capital equal or slightly
lower than aerobic

A common problem with effluent pre-treatment systems is


the long retention time required. Brewery effluent is highly
biodegradable and contains active micro-organisms. If the
effluent remains for an extended period in the balancing
tank, microbial action consumes all the available dissolved
oxygen and the effluent becomes anaerobic leading
to increasing acidity. Acidic conditions cause damage
to concrete structures and inhibit subsequent biological
treatment processes. This can result in discharge limit
violations and odor problems.

Small Brewer Organic Treatment Example

Smallest entry- level aerobic system


There are packaged systems available that can
treat as little as 3,785 lpd or less

38

BrewersAssociation.org

CBs Brewing Company installed an organic pretreatment system at their brewery in Honeoye
Falls, New York. The system reduced BOD levels by
90%. The project was built in partnership with the
village of Honeoye, a small community that has the
capability to treat mainly residential wastewater.
CBs brews about 7,500 BBLs annually. Installation
of an organic pre-treatment system was driven
as a condition of village approvals, not from an
economic return perspective.

Onsite Wastewater Treatment

Other Biological Treatment Options


Optimizing Wastewater Pre-Treatment Operations
Reducing the retention time in the balancing tank
reduces trade effluent charges
The effluent treatment plant at George Bateman &
Sons Brewery consists of a large effluent pumping
station, an unmixed balancing tank, a biotower and
a settlement tank. The Brewery had experienced
problems with a low pH in the final effluent and poor
COD removal.
Measurements of pH at the inlet and outlet of the
balancing tank revealed that the pH was falling
from 7.0 to less than 5.0 during balancing. Although
degradation of organic acids in the biofilter allowed
the pH to rise slightly, the brewery was not reliably
achieving compliance with the consent minimum of
pH 6.0.

The number and variety of biological treatment solutions


scaled for craft brewers is increasing rapidly. Advantages
to such smaller systems can include relative affordability,
smaller footprint, engineering support and lower operating
(power, water, reagent and maintenance) costs.
Notable features of treatment solutions provided by two
vendors during the compilation of this manual include:
Integrated aerobic and anaerobic media
technologies (Baswood AIMS system)
Multiple integrated treatment processes for various
effluent types (Contech Magellan system).
A directory of waste and effluent treatment system suppliers can
be found in the Supplier Directory on BrewersAssociation.org.

The Brewery plans to overcome these problems by


using low-cost methods to reduce the retention time in
the balancing tank. As well as improved compliance
with consent limits, savings in trade effluent charges of
around 3 000/year are anticipated.

Water and Wastewater: Treatment/Volume Reduction Manual

39

section five
Brewery Case Studies

5.1 Water Reduction




Bells Brewery Kalamazoo, Michigan
At Bells Brewery, employees are consistently monitoring
their water use with the goal in mind to decrease the
brewerys water intensity. They use sub-meters to track
water use in their brewhouse, cellar and on both the bottling
and kegging lines. Their CIP system has reduced the amount
of water to clean brewery tanks by about 65% over their
previous procedure. In addition, they have installed a new
filler vacuum pump design, which reduced water that goes
through the drain from 56. 8 liters per minute to 7. 6 liters
per minute. Annually this will save Bells over 9 million liters of
water associated with their filling operation.

Sierra Nevada Chico, California


Sierra Nevada is doing many great things when it comes to
water conservation. In order to know where to go, they first
determined where they were at. Sierra Nevada currently has
five different audits to manage their water use: plantwide
CIP, plant sanitation, fuel cell energy solar, east and west
house brewhouse, and cooling tower audits.

Long Trail has an in-house Heat Recovery System that


condenses the steam back into water and, in doing so,
doing recovers 3. 7 million BTUs per day in the form of heat
energy that is promptly used for the preparation of the next
brew, thereby significantly reducing propane use.

To conserve their water use, the brewery has installed


several new technologies. They replaced bathroom faucet
aerators, which saved close to 800,000 liters of water a
year - providing an immediate payback. They retrofitted
flush valve toilers with dual flush handles, which saved them
almost 300,000 liters a year for a 0.7-year payback. They
installed Air-Cooled Ice Machine, which saves them over 3
million liters a year for a 1.5-year payback. In addition, they
replaced their pre-rinse spray valves, which saved almost 1
million liters a year for an immediate payback.

New Belgium Brewing Company Fort Collins, Colorado

Standing Stone Brewery Ashland, Oregon

New Belgiums packaging hall has some great water-saving


features: The water used to first rinse the inside of the bottles
is recovered and reused on the final exterior rinse. Also, the
CIP system is designed with a hot water recovery tank to
recover heat and water from their hot water sanitizations to
use on the subsequent cleaning cycle. At the brewery, there
is a xeriscaped approach to landscaping that is crucial in
arid climates like Colorado. Xeriscape practices include

At the Standing Stone Brewery restaurant in Ashland,


Oregon, resource conservation is a key message that
they want to convey to the customer. Their kitchen has a
high-temperature dishwasher that reduces the amount of
water and chemicals needed for rinsing and sanitation. This
technology minimizes the use of water as well as reduces the
amount of energy needed for wastewater management by
using fewer chemicals.

Long Trail Brewing Company Bridgewater Corners, Vermont

40

native plants that require little, if any, additional watering as


well as proper soil amendments to help retain moisture. The
approach also calls for watering practices that reduce runoff and evaporation.

BrewersAssociation.org

Brewery Case Studies

5.2 Wastewater Pre-treatment



and power project that is expected to generate 8 to 10% of


the electricity used on Gundersen Lutherans campuses in
La Crosse and Onalaska, WI.

Bluetongue Brewery Warnervale, Australia


Bluetongue Brewery is a new plant in Warnervale on the
Central Coast of New South Wales, Australia. The brewery
is owned by Pacific Beverages, a joint venture between
Coca-Cola Amatil (CCA) and SABMiller.
Onsite at the brewery, a wastewater pre-treatment facility
filters out waste from the brewing process, which eases the
strain that would otherwise be put on the water treatment
center in town.
CST Wastewater Solutions is partnering with Global Water
Engineering (GWE) to deliver and install a treatment system
with best-practice water reuse standards, while at the
same time providing renewable energy for the brewery,
reducing its dependence on fossil fuels. The $120 million
state-of-the-art brewery now being built on NSWs Central
Coast will eventually have an annual capacity of 150 million
liters, making it the Australian states second largest. The
new brewerys wastewater will pass several pre-treatment
steps before entering a GWE ANUBIX-B anaerobic methane
reactor, in which the wastewaters organic content (COD)
is digested by bacteria in a closed reactor, degrading the
compounds and converting them into valuable biogas and
cleaned effluent. This anaerobic treatment will significantly
reduce the brewerys carbon footprint by avoiding the
release of carbon dioxide into the atmosphere.
Biogas from the process will be collected and reused as
renewable energy to power the brewerys boiler.
Treated effluent will then continue to an aerobic posttreatment stage in which organic content is further reduced
by GWEs proprietary MEMBROX Membrane Biological
Reactor (MBR) system.
In the water polishing step, the water from the MBR unit is
sent through a reverse osmosis (RO) installation.
Finally, the effluent is led to a disinfection and storage unit,
where the recycled water will be kept for reuse applications.
City Brewing Company, La Crosse, Wisconsin
Gundersen Lutheran Health System, based in La Crosse,
Wisconsin, has entered into a unique renewable energy
partnership with a local brewing company, City Brewery. In
2009, the two organizations powered up a combined heat

The renewable energy project uses waste biogas discharged


from City Brewerys waste treatment process and turns it into
electricity. Currently, it is generating three million kilowatt
(kW) hours per year; this is equivalent to planting 490 acres
of forest or removing 395 cars from the road and is enough
electricity to power 299 homes.
Heres how it works. The brewing process creates waste that
must be pretreated by City Brewery before it is sent to La
Crosses municipal wastewater treatment facility. Biogas,
including methane, is created during that pre-treatment
process. (Previously, City Brewery flared the gas to dispose of
it.) The combined heat and power project allows the waste
biogas to be captured, cleaned and sent through an engine
Gundersen Lutheran installed at the City Brewery site. The
engine generates electricity that is then transferred to the
power grid. In addition, heat generated from the engine is
captured and recycled back to City Brewerys wastewater
treatment process to make it more efficient.
This renewable energy partnership between Gundersen
Lutheran and City Brewery, and this type of gas-cleaning
system, are both the first of their kind. The project is supported,
in part, by Focus on Energy.
Long Trail Brewing Company - Bridgewater Corners, Vermont
The Long Trail Brewery sits directly on top of a water source
that has been named Vermonts Best Tasting Drinking Water.
The artesian well supplies the brewery with up to 76,000 liters
a day of crystal clear quality water. In order to maintain the
pristine natural environment, however, Long Trail developed
a proprietary process for removing nearly all the impurities
from the brewerys wastewater. They are licensed by the
state of Vermont to return this high quality effluent to the
ground via underground injection into onsite leach fields.
Sierra Nevada Chico, California
Sierra Nevada focuses on minimizing the brewerys usage
of its water resources and continually audits the process
to minimize wasteful practices. They have been able to
reduce their water usage to almost half of the historical
value typically used by breweries in the United States.
Sierra Nevada made the commitment several years ago to
treat all of the brewerys production wastewater to remove
this burden from the local municipality. They installed a

Water and Wastewater: Treatment/Volume Reduction Manual

41

European-designed, two-step anaerobic and aerobic


treatment plant that reprocesses and purifies all of the water
produced from their brewing operations.
The methane generated from the anaerobic digestion of
the wastewater is captured and used to fuel their boilers.
This uses 100% of an energy byproduct as fuel for another
process, instead of releasing it into the atmosphere.
Additionally, water used for truck washing is collected and
purified through their own facility.
Stone Brewing Company Escondido, California
Stone Brew Co. in Escondido, California, built a brand
new brewing facility with a simple wastewater treatment
system adjacent to a restaurant and 1-acre beer garden
in 2005. After some significant production growth, the city
threatened to significantly increase the brewerys water rate
to be able to accommodate the higher organic strength
and solids content in the water. This resulted in Stone Brews
installation of an aeration tank to meet biochemical oxygen
demand (BOD) limits and a dissolved air flotation (DAF) unit
to meet total suspended solids (TSS) limits in 2008. By doing
this, the brewery was able to negotiate with the City to leave
the water rate at the existing value. Typical influent water
quality to the WWTP was 12,000 mg COD/L, 7300 mg TSS/L at
a pH of 5.4. The issues with running an industrial WWTP with
a rudimentary design, however, quickly became apparent.
Due to the degree of difficulty in treating the brewery
wastewater, which consists mostly of sugars, proteins,
carbohydrates and yeast, the DAF was not able to achieve
sufficient solids removal or facilitate consistent BOD removal
required to meet the local limitations. Issues included
excessive process control problems, such as the need
to haul away sludge that could not be separated by the
DAF unit, foaming events and overflows, high chemical
consumption, multiple mechanical failures and trouble with
sludge dewatering. These factors caused breaches in water
quality restrictions, costly repairs and time consuming labor.
Since the WWTP was onsite next to a restaurant and outdoor
beer garden, there were also concerns with the unpleasant
odors created from poor biological performance and sludge
handling becoming visible to customers. After a little over a
year of operation with the problem-riddled system, the plant
decided it would be advantageous to change the treatment
scheme to something better suited for their particular
wastewater.
The decision to replace the DAF with a membrane
bioreactor (MBR) system was mainly motivated by the
guarantee in TSS removal via membrane filtration. Other
42

BrewersAssociation.org

reasons included enhanced BOD removal and the


possibility to reuse the effluent water within the plant. The
MBR system was commissioned in January 2010 and was
designed to process 227,124 liters per day. It utilized two
HYDRAsub-MBR HSM500 modules, each containing 500
m2 of surface area. Upon stabilization of the system, various
benefits of the MBR were soon realized. First of all, TSS in the
effluent was drastically reduced and COD removal was
greatly improved. Process control was enhanced so that
all activated sludge could be treated and recycled back
to the aeration tank, not hauled away. The simplistic and
almost fully automatic operation of the system resulted in
low maintenance and labor time compared to the DAF. The
chemical usage and cost for separating solids and sludge
dewatering decreased significantly. Finally, as soon as the
MBR system was stabilized, an RO system was commissioned
to further treat the effluent for reuse purposes.

5.3 Community Outreach




Founders Brewing Company Grand Rapids, Michigan
Founders Brewing Company and Grand Rapids Whitewater
have partnered together in an initiative to restore the Grand
River to its original splendor by putting the Rapids back in the
Grand. Their collective vision is to create a safe, beautiful,
more natural and healthy resource for the community.
The improved river landscape will encourage canoeing and
kayaking while providing an enhanced environment for
fishermen and other recreationalists. Rapids will promote a
cleaner, healthier aquatic ecosystem, strengthening marine
life habitats.
To help bring this vision to life, they ask customers to donate
$1 to Grand Rapids Whitewater each time they refill a
Whitewater growler in the brewery taproom; they are also
raising awareness for the cause with a specialty water
bottle. Their motto is to: share a beer or two, and share in
the vision for changing the face of Grand Rapids.
New Belgium Brewing Company Fort Collins, Colorado
In 2010, New Belgium Launched SaveTheColorado.org,
a campaign to fund water stewardship efforts on the
Colorado River (which supplies almost half the water
coming to Fort Collins). New Belgium committed $300,000
over three years to nonprofit organizations working to study
and repair the Colorado River. They are also joined by
several other companies and individuals in this effort (www.
savethecolorado.org).

appendix a
Tool Box

Guidance and Checklists





Guidance Sanitary Water Usage


Guidance Water losses from Leaks
Checklist Water Efficiency Opportunity (USEPA)
Checklist Water Audit Data Collection Sheet

On-Line Excel-Based Tools



Calculating the full cost of water


Calculating the costs and returns of pre-treatment

Water and Wastewater: Treatment/Volume Reduction Manual

43

references

44

Atlanta Brewery Produces Rainwater Beer,


ecolocalizer. com, Becky Striepe (September 2009)
New Belgium Brewing Company, Inc. Sustainability
Management System Version 2011, New Belgium
Brewing Company (2011)
Environmental Guidelines for Breweries, Multilateral
Investment Guarantee Agency
Minimization of freshwater consumption in brewery,
University of Maribor, Chemical Engineering
Department, H. Tokos, P. Glavi, (September 2011)
A Good Practice Guide Reducing Water and
Effluent Costs in Breweries, accepta, (August, 1998)
Water management at a malted barley brewery,
AI van der Merwe and JFC Friend, Environmental
Engineering Group, Department of Chemical
Engineering, University of Pretoria, Pretoria, South
Africa (Jul, 2002)
Pollution Prevention and Abatement Handbook,
World Bank Group (July 1998)
Lean & Water Toolkit, Environmental Protection
Agency (October 2011)
Water Use Benchmarking in the Beverage Industry,
Beverage Industry Environmental Roundtable
(2011)
Water, wastewater and waste management in
brewing industries, Journal of Cleaner Production
14, Luc Fillaudeau a, Pascal Blanpain-Avet,
Georges Daufin (March 2005)
Practical Wastewater Pre-treatment Strategies for
Small Breweries, BridgePort Brewing Company, Karl
Ockert (2002)
Engineering Better Waste Removal, MBAA Midwest
Technical Conference (September 2008)
Brewery Wastewater: Solutions for the Problem,
2010 Water and Wastewater Conference, Fred M.
Scheer (2010)
Advanced pre-treatment option for processing
high-strength food & beverage wastewaters,
Baswood BioViper (2004)

BrewersAssociation.org

Evolution of Wastewater Treatment System, Stone


Brewing Company (2010)
Future Waster and Effluent Management,
Environment Agency, Tom Bruce (March 2009)
Why does love have to be so sad? New Holland
Brewing Company, John Haggerty
Great Lakes Water Conservation Conference for
craft brewers and cheese makers (October 2010)
An Independent Brewerys Methodology & Reality
in Balancing Environmental Stewardship, Spoetzl
Brewery, Jim Revel, Steve James, Peter Koestler
(2010)
Wastewater Pre-treatment for Small Breweries,
Custom BrewCrafters, Inc. Jason Fox (2011)
Research Allows Identification of Winery
Wastewater Source Reduction Opportunities, Wine
Institute, Kennedy/Jenks Consultants
Land Application Study and Development of
Guidelines for Best Management, Wine Institute,
Kennedy/Jenks Consultants
Brewery Optimization Water Reduction in
Cleaning Operations, Alfalaval, Linda Rastani and
John Berardino
Preparing for a Water Audit, Alliance for Water
Efficiency, Thomas Pape
Bluetongue Brewery water re-use project, Food
Magazine (July 2009)
Water and its use in the Brewery, BridgePort
Brewing Company, Karl Ockert (2009)
Sierra Nevada Brewing Co. Water Conservation
Efforts, Sierra Nevada, Fred Strachan
Brewery Optimization Water Reduction in
Cleaning Operations, Alfa Laval Inc., Linda A.
Rastani (October 2010)
Great Lakes Water Conservation Conference,
Peter J. Fernholz (October 2010)
Principles and Practice of Cleaning in Place,
BRIGGS of Burton INC, Graham Broadhurst
The Guide to Water Conservation and Sustainable

Energy Usage, GHG Reduction, Efficiency and Load Management Manual

Practices in Industrial Kitchens


The Price of Water: Should it be higher? Great
Lakes Water Conservation Workshop, Sammis B.
White, G. William Page, Michael Wolkoff (March
2010)
Post Consumption Water Use The Hidden Waste,
Great Lakes Craft Brewers & Water Conservation
Conference, Thomas E. Pape (October 2009)
Water Intensity Base lining for Breweries, Bells
Brewery, Evan Meffert
Green Restaurant Guide: Water Conservation, San
Francisco Department of Public Health (March
2009)
A Water Conservation Guide for Commercial,
Institutional and Industrial Users, New Mexico Office
of the State Engineer (2009)

Water and Wastewater: Treatment/Volume Reduction Manual

45

selected web links

46

Conserve Great Lakes, www.conserve-greatlakes.com/

Brewers For Clean Water, www.nrdc.org/water/brewers-for-clean-water/

The Brewers Handbook, www.beer-brewing.com/default.htm

Founders Brewing Company, www.foundersbrewing.com

Long Trail Brewer, www.longtrail.com

Eel River Brewing company, www.eelriverbrewing.com

National Restaurant Association (ConsSERVE), www.conserve.restaurant.org/

Washington Restaurant Association, www.warestaurant.org/

University of Washington, www.washington.edu/

United States Environmental Protection Agency, www.epa gov

EPA Water Sense, www.epa.gov/watersense

Gillette Stadium, www.waterefficiency.net/WE/Articles/The_Use_of_Onsite_Wastewater_Treatment_


Systems_in_12108.aspx

Denver Sustainable Event Planning Guide,


www.greenprintdenver.org/2009/04/27/sustainable-event-planning-guide/

BIER (Beer Industry Environmental Roundtable), www.bieroundtable.com/index.htm

Brewers Association of Canada, www.brewers.ca/en/environmental-leadership

BrewersAssociation.org

Energy Usage, GHG Reduction, Efficiency and Load Management Manual

image credits
1. Data used courtesy of the Beverage Industry Environmental Roundtable, 2011 Water Use Benchmarking in the
Beverage Industry
2. Diagram courtesy of the National Drought Mitigation Center at the University of Nebraska
3. Image courtesy of the Sierra Nevada Brewing Company
4. Image courtesy of Caseys Brewery, Sydney, Australia
5. Image courtesy of Goose Island Beer Company
6. Image courtesy of the Sierra Nevada Brewing Company
7. Image courtesy of the Sierra Nevada Brewing Company
8. Image courtesy of the Sierra Nevada Brewing Company
9. Image courtesy of the Sierra Nevada Brewing Company
10. Shutterstock, LLC **

Water and Wastewater: Treatment/Volume Reduction Manual

47

You might also like