Design Calculation

Of

TERMINAL A

CODE

CALCULATIONS

RESUL

TERMINAL A
SURFACE AREA OF STRUCTURE
Total Length of the terminal A = 475m
Width of a sheet piling = 1.4m
Actual width of a unfolded sheet piling = 1.6m
Correction factor for metre length of a sheet piling:
= 1.6
1.4
= 1.14

DNVRP-

a. Surface area of newly installed sheet piling, A1, 2.5m depth


= 475 * 2.5* 1.14
= 1,353.75 m2
1,353.75 m2
b. Surface area of existing sheet piling, A2, 5.5m depth
= 475 * 5.5 * 1.14
= 2,978.25 m2
2,978.25 m2

CODE

CALCULATIONS

RESUL

DESIGN PARAMETERS
The following parameters have been considered in the design of
Cathodic Protection System for Tin can Port Terminal A and
adequate values or categories have also been selected for these
parameters to ensure that a protective CP potentials would be
maintained for the sheet piling spanning the terminal.
DNVRP-

BS
7361DNVRP-

DNVRP-

a.

Current density for area below high tide level (initial) = 150 mA/m 2

b.

Current density for area below high tide level (mean) = 70 mA/m 2

c.

Current density for area below high tide level (final) = 100 mA/m2

d.

Driving potential (initial life) = 250 mV

e.

Driving potential (mid life) = 150 mV

f.

Design life = 15years

g.

Cathodic protection method: Sacrificial anodes

h.

Coating conditions: Category I

i.

Anode Material: GALVALUM-III

j.

Anode Utilization factor = 0.9

k.

Electrochemical capacity of Anode material (seawater) = 2000 AH/Kg (min.)

l.

CODES

Seawater resistivity = 0.25 ohm-m

CALCULATIONS

COATING BREAKDOWN FACTOR, FC


DNVRP-

Fci = Coating Breakdown factor at initial life of anode

RESUL

Fci = Coating Breakdown factor at mean life of anode


Fci = Coating Breakdown factor at final life of anode
Components
1 A1, newly
installed sheet
piling
2 A2, existing sheet
piling

CODES

DNVRP-

Status

Fci

Fcf

Remarks

0.1

Fc
m
0.6

Mild

1.0

Category;
a= 0.1,
b= 0.1

Severe

1.0

1.0

1.0

CALCULATIONS

RESUL

CURRENT DEMAND (INITIAL)


The following calculations would consider appropriate current
density stated above with other parameters for the initial current
demand of the structure for initial polarisation to a protective volt.

Current Demand, Ic = Ac ic fc
Where Ac = Surface Area of indicated components.
ici = Initial Current Density
fci = Coating Breakdown factor (initial)
1. Newly installed sheet piling, A1, 2.5m depth
Current Demand = 1,353.75 * 150 * 0.1
1000
= 20.31A
20.31A
2. Existing sheet piling, A2, 5.5m depth
Current Demand =

2,978.25 * 150 * 1.0


1000
= 446.74A

446.74A

CODES

DNVRP-

CALCULATIONS

RESUL

MASS OF ANODE REQUIRED (INITIAL)


The mass of anode required to maintain cathodic protection
through out the design life of 15 years for individual component at
initial current demand:
Ma = Ici tf 8760

u
where Ma = Mass of anode required.
Ici = Current demand (initial)
tf = Design life
u = Electrochemical capacity of the anode
= Anode utilization factor
Assumptions
1. 15 years of design life with adequate cathodic protection
is considered
2. Anode utilization factor of 0.9 is applied.
1. Newly installed sheet piling, A1, 2.5m depth
Mass of anode required, Ma = 20.31 * 15 * 8760
0.9 * 2000
= 1,482.63kg
1,482.63kg
2. Existing sheet piling, A2, 5.5m depth
Mass of anode required, Ma = 446.74 * 15 * 8760
0.9 * 2000
= 32,612.02kg
32,612.02kg
s/
n

Components

Newly Installed sheet


piling
Existing sheet piling

Total
CODES

Initial
Current
Demand,
A
20.31

Mass of
Anode,
kg

446.74

32,612.0
2
34,094.
65

467.05

CALCULATIONS

1,482.63

RESUL

CURRENT DEMAND (MEAN)


The following calculations would consider appropriate current
density stated above with other parameters for the mean current
demand of the structure.
Current Demand, Ic = Ac ic fc
Where Ac = Surface Area of indicated members.
icm = Mean Current Density

fcm = Coating Breakdown factor (mean)


1. Newly installed sheet piling, A1, 2.5m depth
Current Demand = 1,353.75 * 70 * 0.6
1000
= 56.86A
56.86A
2. Existing sheet piling, A2, 5.5m depth
Current Demand =

2,978.25 * 70 * 1.0
1000
= 208.47A

208.48A

CODES

CALCULATIONS

RESUL

MASS OF ANODE REQUIRED (MEAN)


The mass of anode required to maintain cathodic protection
through out the design life of 15 years for individual component at
mean current demand:
Ma = Icm tf 8760
u
where Ma = Mass of anode required.
Icm = Current demand (mean)

tf = Design life
u = Electrochemical capacity of the anode
= Anode utilization factor
Assumptions
3. 15 years of design life with adequate cathodic protection
is considered
4. Anode utilization factor of 0.9 is applied.
1. Newly installed sheet piling, A1, 2.5m depth
Mass of anode required, Ma = 56.86 * 15 * 8760
0.9 * 2000
= 4,150.78kg
4,150.78kg
2. Existing sheet piling, A2, 5.5m depth
Mass of anode required, Ma =

208.48 * 15 * 8760
0.9 * 2000
= 15,219.04kg

15,219.04kg
s/
n

Components

Newly Installed sheet


piling
Existing sheet piling

Total
CODES

Mean
Current
Demand,
A
56.86

Mass of
Anode,
kg

208.48

15,219.0
4
19,369.
82

265.34

4,150.78

CALCULATIONS

RESUL

CURRENT DEMAND (FINAL)


The following calculations would consider appropriate current
density stated above with other parameters for the final current
demand of the structure.
Current Demand, Ic = Ac ic fc
Where Ac = Surface Area of indicated components.
icf = final Current Density
fcf = Coating Breakdown factor (final)

1. Newly installed sheet piling, A1, 2.5m depth


Current Demand = 1,353.75 * 100 * 1.0
1000
= 135.38A
135.38A
2. Existing sheet piling, A2, 5.5m depth
Current Demand =

2,978.25 * 100 * 1.0


1000
= 297.83A

297.83A

CODES

DNVRP-

CALCULATIONS

RESUL

MASS OF ANODE REQUIRED (FINAL)


The mass of anode required to maintain cathodic protection
through out the design life of 15 years for individual component at
final current demand:
Ma = Icm tf 8760
u
where Ma = Mass of anode required.
Icf = Current demand (final)
tf = Design life
u = Electrochemical capacity of the anode
= Anode utilization factor

Assumptions
5. 15 years of design life with adequate cathodic protection
is considered
6. Anode utilization factor of 0.9 is applied.
1. Newly installed sheet piling, A1, 2.5m depth
Mass of anode required, Ma =

135.38 * 15 * 8760
0.9 * 2000
= 9,882.74kg

9,882.74kg
2. Existing sheet piling, A2, 5.5m depth
Mass of anode required, Ma =

297.83 * 15 * 8760
0.9 * 2000
= 21,741.59kg

21,741.59kg
s/
n

Components

Newly Installed sheet


piling
Existing sheet piling

Total
CODES

Final
Current
Demand,
A
135.38

Mass of
Anode,
kg

297.83

21,741.5
9
31,624.
33

433.21

9,882.74

CALCULATIONS

RESUL

ELECTION OF ANODE TYPE


DNVRP-

The selection of anode type for Terminal A Sheet piling was


determined by the size, spatial uniformity in the geometrical
configuration of the sheet piling and forces that would exert on the
fabricated anodes during installation and operation
Based on above criteria and several, The Stand-off Anode was
selected with following specifications:
Type

750NP

Net Wt, Kg

75

Width, mm

184

Height,
mm

184

Length,
mm

827

Overall
Length,
mm

1,469

Core
Specificati
on Flat
bar

50 * 12mm

Maximum
Current
available

1.917

Complete anode schematic is shown in the attached drawings.


DNVRP-

CALCULATION OF ANODE RESISTANCE IN SEAWATER


To find the resistance of 750NP
Manufacturer specification:
Seawater resistivity = 0.25 ohm.m
Driving potential = 250mV
Current = 1.917A
Ra =
2**L

CODES

4L
In
r

-1

CALCULATIONS

RESUL

where = seawater resistivity


L = Length of Anode material
r = radius of Anode cross-section
The cross-section of the selected anode is a rectangular,
Thus, radius =

radius =

2(w + h)
2*
736
6.284

radius = 117.12mm

Rai

0.25
4 0.827
2 3.142 0.827

In

-1
0.117

= 0.048 2.34
= 0.112 ohm

Rai = 0.112 ohm


CALCULATION OF ANODE CURRENT OUTPUT
DNVRP-

I a = E c - Ea
Ra
But Manufacturers specification states the following conditions
Seawater resistivity = 0.25 ohm.m
Driving voltage = 250mV
Max available Current = 1.917 (Initial Life Current)

Iai = 1.917 A

Therefore Ra = 0.250 / 1.917


= 0.130 ohm
The difference in resistance = 0.130 0.112 = 0.018 ohm can be
attributed to resistive component of the anode insert.
CODES

DNVRP-

CALCULATIONS

FINAL ANODE CURRENT OUTPUT


Mass of remaining Aluminium anodic material at the
Final life is 10% of the total mass i.e. 90% anode efficiency.
Mass (end-life) = Mass (initial life) (1 U)
Mass (end life) = 75 kg * (1 0.9)
Mass (end life) = 75 * 0.1
Mass (end life) = 7.5 kg
Volume of remaining net mass of anode, V (end life)

RESUL

= Mass of Aluminium
Density of Aluminium
Volume (end life) = 7.5 kg
2678 kg / m3
= 0.0028 m3
Widt
h
mm
184

Initi
al
Life
Final 0.00
Life
2

DNV-RPB401

Heigh
t
mm
184

Length Net
mm
Wgt
kg
827
75

Volume
m3

0.002

744.3

0.0028

7.5

0.0280

Assume the cross-section of the selected anode still remains rectangular


Thus, radius =

2(w + h)
2*

radius =

0.008
6.284

radius = 0.0012mm

CODES

CALCULATIONS

RESUL

Therefore, resistance of anode at end-life:


Rf

0.25
4 0.7443
2 3.142 0.7443

In

-1
0.0012

= 0.053 6.816
= 0.36 ohm
Raf = 0.360 ohm
I a = E c - Ea
Ra

Anode Output (end life),Iif = Ec - Ea


Rif
= 0.25
0.36
= 0.69A
Iaf = 0.694
A

CODES

CALCULATIONS

A. NUMBER OF ANODE (INITIAL LIFE)


1. New Installed sheet piling
= 20.31 / 1.917 = 10.59 approx. 11no.
2. Existing sheet piling
= 446.74 / 1.917 = 233.04 approx. 233

RESUL

s/
n

Components

Initial
Current
Deman
d, A

Newly Installed
sheet piling

20.31

12

Anode
Current
Output
(Initial
life), A
23.00

Existing sheet
piling

446.74

234

448.58

467.05

246

471.58

TOTAL

No of
Anode,
kg

B. NUMBER OF ANODE (FINAL LIFE)


1. New Installed sheet piling
= 135.38 / 0.694 = 195.07 approx. 196no.
2. Existing sheet piling
= 297.83 / 0.694 = 429.15 approx. 430no.
s/
n

Components

Final
Current
Deman
d, A

Newly Installed
sheet piling

135.38

200

Anode
Current
Output
(Final
life), A
138.00

Existing sheet
piling

297.83

435

300.15

433.21

635

438.15

TOTAL

CODES

No of
Anode,
kg

CALCULATIONS

RESUL

ACCEPTANCE CRITERIA
DNVRP-

The current outputs as per the anode mass provided for respective
members are being considered if it satisfies the acceptance
criteria as stated below:
Thus:
i. Ca tot = N * Ca Icm * tf * 8760
ii. Iatot i = N * Iai Ici

iii. Iatot f = N * Iaf Icf


i. Ca tot = N * Ca Icm * tf * 8760
Ca = individual anode current capacity
Ca = m a X X u
ma = net mass per anode, kg
= anode electrochemical capacity, AH / kg
u = anode utilisation factor
Ca = 75 kg X 2000 AH/kg X 0.9
Ca = 135,000 AH per anode
Therefore; Ca tot = 135,000 AH per anode x 635 Icm * tf * 8760
= 85,725,000 AH 265.34 * 15 * 8760
= 85,725,000 AH 34,865,676 AH
Accepted
ii. Iatot i = N * Iai Ici
Iatot i = 635 * 1.917 467.05
= 1,217.29 A 467.05 A
Accepted

CODES

CALCULATIONS

RESUL

iii. Iatot f = N * Iaf Icf


Iatot f = N * Iaf Icf
= 635 * 0.690 433.21 A
= 438.15 A 433.21 A
Accepted

The number of anodes on the members of Terminal A is

s/
n
1
2

Components

No of Anode, kg

Newly Installed sheet


piling

200

Existing sheet piling

435

TOTAL

635

Design Calculation
Of

TERMINAL B

CODE

CALCULATIONS

RESUL

TERMINAL B
SURFACE AREA OF STRUCTURE
Total Length of the terminal B = 750m
Width of a sheet piling = 1.4m
Actual width of a unfolded sheet piling = 1.6m
Correction factor for metre length of a sheet piling:
= 1.6
1.4
= 1.14

DNV-

a. Surface area of newly installed sheet piling, B1, 2.5m depth


= 750 * 2.5* 1.14

= 2,137.50 m2
2,137.50 m2
b. Surface area of existing sheet piling, B2, 5.5m depth
= 750 * 5.5 * 1.14
= 4,702.50 m2
4,702.50 m2

CODE

CALCULATIONS

RESUL

DESIGN PARAMETERS
The following parameters have been considered in the design of
Cathodic Protection System for Tin can Port Terminal B and
adequate values or categories have also been selected for these
parameters to ensure that a protective CP potentials would be
maintained for the sheet piling spanning the terminal.
DNVRP-

DNVRP-

a.

Current density for area below high tide level (initial) = 150 mA/m 2

b.

Current density for area below high tide level (mean) = 70 mA/m 2

c.

Current density for area below high tide level (final) = 100 mA/m2

d.

Driving potential (initial life & final life) = 250 mV

e.

Driving potential (mid life) = 150 mV

f.

Design life = 15years

DNVRP-

g.

Cathodic protection method: Sacrificial anodes

h.

Coating conditions: Category I

i.

Anode Material: GALVALUM-III

j.

Anode Utilization factor = 0.9

k.

Electrochemical capacity of Anode material (seawater) = 2000 AH/Kg (min.)

l.

CODES

Seawater resistivity = 0.25 ohm-m

CALCULATIONS

RESUL

COATING BREAKDOWN FACTOR, FC


DNVRP-

Fci = Coating Breakdown factor at initial life of anode


Fci = Coating Breakdown factor at mean life of anode
Fci = Coating Breakdown factor at final life of anode
Components
1 A1, newly
installed sheet
piling
2 A2, existing sheet
piling

Status

Fci

Fcf

Remarks

0.1

Fc
m
0.6

Mild

1.0

Category;
a= 0.1,
b= 0.1

Severe

1.0

1.0

1.0

CODES

DNVRP-

CALCULATIONS

RESUL

CURRENT DEMAND (INITIAL)


The following calculations would consider appropriate current
density stated above with other parameters for the initial current
demand of the structure for initial polarisation to a protective volt.
Current Demand, Ic = Ac ic fc
Where Ac = Surface Area of indicated components.
ici = Initial Current Density
fci = Coating Breakdown factor (initial)
1. Newly installed sheet piling, B1, 2.5m depth
Current Demand = 2,137.50 * 150 * 0.1
1000
= 32.06A
32.06A
2. Existing sheet piling, B2, 5.5m depth
Current Demand =

4,702.50 * 150 * 1.0

1000
= 705.38A
705.38A

CODES

DNVRP-

CALCULATIONS

RESUL

MASS OF ANODE REQUIRED (INITIAL)


The mass of anode required to maintain cathodic protection
through out the design life of 15 years for individual component at
initial current demand:
Ma = Ici tf 8760
u
where Ma = Mass of anode required.
Ici = Current demand (initial)
tf = Design life
u = Electrochemical capacity of the anode
= Anode utilization factor
Assumptions
7. 15 years of design life with adequate cathodic protection
is considered
8. Anode utilization factor of 0.9 is applied.
1. Newly installed sheet piling, B1, 2.5m depth
Mass of anode required, Ma = 32.06 * 15 * 8760
0.9 * 2000

= 2,340.38kg
2,340.28kg
2. Existing sheet piling, B2, 5.5m depth
Mass of anode required, Ma = 705.38 * 15 * 8760
0.9 * 2000
= 51,492.74kg
51,492.74kg
s/
n

Components

Newly Installed sheet


piling
Existing sheet piling

Initial
Current
Demand,
A
32.06

Mass of
Anode,
kg

705.38

51,492.7
4
53,833.
02

Total
CODES

737.44

CALCULATIONS

2,340.28

RESUL

CURRENT DEMAND (MEAN)


The following calculations would consider appropriate current
density stated above with other parameters for the mean current
demand of the structure.
Current Demand, Ic = Ac ic fc
Where Ac = Surface Area of indicated components.
icm = Mean Current Density
fcm = Coating Breakdown factor (mean)
1. Newly installed sheet piling, B1, 2.5m depth
Current Demand = 2,137.50 * 70 * 0.6
1000
= 89.78A
89.78A
2. Existing sheet piling, B2, 5.5m depth
Current Demand =

4,702.50 * 70 * 1.0
1000
= 329.18A

329.18A

CODES

CALCULATIONS

RESUL

MASS OF ANODE REQUIRED (MEAN)


The mass of anode required to maintain cathodic protection
through out the design life of 15 years for individual component at
mean current demand:
Ma = Icm tf 8760
u
where Ma = Mass of anode required.
Icm = Current demand (mean)
tf = Design life
u = Electrochemical capacity of the anode
= Anode utilization factor
Assumptions
9. 15 years of design life with adequate cathodic protection
is considered
10.
Anode utilization factor of 0.9 is applied.
1. Newly installed sheet piling, B1, 2.5m depth
Mass of anode required, Ma = 89.78 * 15 * 8760
0.9 * 2000
= 6,553.94 kg
6,553.94kg

2. Existing sheet piling, B2, 5.5m depth


Mass of anode required, Ma =

329.18 * 15 * 8760
0.9 * 2000
= 24,030.14kg

24,030.14kg
s/
n

Components

Newly Installed sheet


piling
Existing sheet piling

Mean
Current
Demand,
A
89.78

Mass of
Anode,
kg

329.18

24,030.1
4
30,564.
08

Total
CODES

418.96

6,553.94

CALCULATIONS

RESUL

CURRENT DEMAND (FINAL)


The following calculations would consider appropriate current
density stated above with other parameters for the final current
demand of the structure.
Current Demand, Ic = Ac ic fc
Where Ac = Surface Area of indicated components.
icf = final Current Density
fcf = Coating Breakdown factor (final)
1. Newly installed sheet piling, B1, 2.5m depth
Current Demand = 2,137.50 * 100 * 1.0
1000
= 213.75A
213.75A
2. Existing sheet piling, B2, 5.5m depth
Current Demand =

4,702.50 * 100 * 1.0


1000
= 470.25A

470.25A

CODES

DNVRP-

CALCULATIONS

RESUL

MASS OF ANODE REQUIRED (FINAL)


The mass of anode required to maintain cathodic protection
through out the design life of 15 years for individual component at
final current demand:
Ma = Icm tf 8760
u
where Ma = Mass of anode required.
Icf = Current demand (final)
tf = Design life
u = Electrochemical capacity of the anode
= Anode utilization factor
Assumptions
11.

15 years of design life with adequate cathodic protection


is considered
12.
Anode utilization factor of 0.9 is applied.
1. Newly installed sheet piling, B1, 2.5m depth
Mass of anode required, Ma =

213.75 * 15 * 8760
0.9 * 2000
= 15,603.75kg

15,603.75kg
2. Existing sheet piling, B2, 5.5m depth
Mass of anode required, Ma =

470.25 * 15 * 8760

0.9 * 2000
= 34,328.25kg
34,328.25kg
s/
n

Components

Newly Installed sheet


piling
Existing sheet piling

Total
CODES

Final
Current
Demand,
A
213.75
470.25
684.00

Mass of
Anode,
kg
15,603.7
5
34,328.2
5
49,932.
00

CALCULATIONS

RESUL

ELECTION OF ANODE TYPE


DNVRP-

The selection of anode type for Terminal B Sheet piling was


determined by the size, spatial uniformity in the geometrical
configuration of the sheet piling and forces that would exert on the
fabricated anodes during installation and operation
Based on above criteria and several, The Stand-off Anode was
selected with following specifications:
Type

750NP

Net Wt, Kg

75

Width, mm

184

Height,
mm

184

Length,
mm

827

Overall
Length,
mm

1,469

Core
Specificati
on Flat
bar
Maximum
Current
available

50 * 12mm

1.917

Complete anode schematic is shown in the attached drawings.


DNV-

CALCULATION OF ANODE RESISTANCE IN SEAWATER


To find the resistance of 750NP
Manufacturer specification:
Seawater resistivity = 0.25 ohm.m
Driving potential = 250mV
Current = 1.917A
Ra =
2**L

CODES

4L
In
r

-1

CALCULATIONS

RESUL

where = seawater resistivity


L = Length of Anode material
r = radius of Anode cross-section
The cross-section of the selected anode is a rectangular,
Thus, radius =

2(w + h)
2*

radius =

736
6.284

radius = 117.12mm

Rai

0.25
4 0.827
2 3.142 0.827

In

-1
0.117

= 0.048 2.34
= 0.112 ohm

Rai = 0.112 ohm


CALCULATION OF ANODE CURRENT OUTPUT
DNVRP-

I a = E c - Ea

Ra
But Manufacturers specification states the following conditions
Seawater resistivity = 0.25 ohm.m
Driving voltage = 250mV
Max available Current = 1.917 (Initial Life Current)

Iai = 1.917

A
Therefore Ra = 0.250 / 1.917
= 0.130 ohm
The difference in resistance = 0.130 0.112 = 0.018 ohm can be
attributed to resistive component of the anode insert.
CODES

DNVRP-

CALCULATIONS

RESUL

FINAL ANODE CURRENT OUTPUT


Mass of remaining Aluminium anodic material at the
Final life is 10% of the total mass i.e. 90% anode efficiency.
Mass (end-life) = Mass (initial life) (1 U)
Mass (end life) = 75 kg * (1 0.9)
Mass (end life) = 75 * 0.1
Mass (end life) = 7.5 kg
Volume of remaining net mass of anode, V (end life)
= Mass of Aluminium
Density of Aluminium
Volume (end life) = 7.5 kg
2678 kg / m3
= 0.0028 m3

DNV-RPB401

Widt
h
mm
184

Initi
al
Life
Final 0.00
Life
2

Heigh
t
mm
184

Length Net
mm
Wgt
kg
827
75

Volume
m3

0.002

744.3

0.0028

7.5

0.0280

Assume the cross-section of the selected anode still remains rectangular


Thus, radius =

2(w + h)
2*

radius =

0.008
6.284

radius = 0.0012mm

CODES

CALCULATIONS

RESUL

Therefore, resistance of anode at end-life:


Rf

0.25
4 0.7443
2 3.142 0.7443

In

-1
0.0012

= 0.053 6.816
= 0.36 ohm
Raf = 0.360 ohm
I a = E c - Ea
Ra

Anode Output (end life),Iif = Ec - Ea


Rif
= 0.25
0.36
= 0.69A
Iaf =
0.694 A

CODES

CALCULATIONS

RESUL

A. NUMBER OF ANODE (INITIAL LIFE)


1. New Installed sheet piling
= 32.06 / 1.917 = 16.72 approx. 17 no.
2. Existing sheet piling
= 705.38 / 1.917 = 367.96 approx. 368
s/
n

Components

Initial
Current
Deman
d, A

Newly Installed
sheet piling

32.06

18

Anode
Current
Output
(Initial
life), A
34.51

Existing sheet
piling

705.38

370

709.29

737.44

388

746.80

TOTAL

No of
Anode,
kg

B. NUMBER OF ANODE (FINAL LIFE)


1. New Installed sheet piling
= 213.75 / 0.694 = 307.99 approx. 308 no.
2. Existing sheet piling
= 470.25 / 0.694 = 677.59 approx. 678 no.

s/
n

Components

Final
Current
Deman
d, A

Newly Installed
sheet piling

213.75

310

Anode
Current
Output
(Final
life), A
215.14

Existing sheet
piling

470.25

700

485.80

684.00

1010

700.94

TOTAL

CODES

No of
Anode,
kg

CALCULATIONS

RESUL

ACCEPTANCE CRITERIA
DNVRP-

The current outputs as per the anode mass provided for respective
members are being considered if it satisfies the acceptance
criteria as stated below:
Thus:
i. Ca tot = N * Ca Icm * tf * 8760
ii. Iatot i = N * Iai Ici
iii. Iatot f = N * Iaf Icf
i. Ca tot = N * Ca Icm * tf * 8760
Ca = individual anode current capacity
Ca = m a X X u
ma = net mass per anode, kg
= anode electrochemical capacity, AH / kg
u = anode utilisation factor
Ca = 75 kg X 2000 AH/kg X 0.9
Ca = 135,000 AH per anode
Therefore; Ca tot = 135,000 AH per anode x 1010 Icm * tf * 8760
= 136,350,000 AH 418.96 * 15 * 8760

= 136,350,000 AH 55,051,344 AH
Accepted
ii. Iatot i = N * Iai Ici
Iatot i = 1010 * 1.917 737.44
= 1,936.17 A 737.44 A
Accepted

CODES

CALCULATIONS

RESUL

iii. Iatot f = N * Iaf Icf


Iatot f = N * Iaf Icf
= 1010 * 0.690 684.00 A
= 696.90 A 684.00 A
Accepted

The number of anodes on the members of Terminal B is


s/
n
1
2

Components

No of Anode, kg

Newly Installed sheet


piling

310

Existing sheet piling

700

TOTAL

1010