You are on page 1of 33

Air Conditioners

Technical Data
Outdoor units optimized for seasonal efficiency

EEDEN12-100

RZQSG-LY1
Downloaded from www.Manualslib.com manuals search engine

Outdoor Unit Outdoor units optimized for seasonal efficiency RZQSG-LY1

TABLE OF CONTENTS
RZQSG-LY1

Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Nominal Capacity And Nominal Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

............................................................... 9

Combination table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Combination Table

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

Capacity tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

11

Cooling Capacity Tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .


Heating Capacity Tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Capacity Correction Factor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

11

Dimensional drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

18

Dimensional Drawings

10

12

20

Piping Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Piping Diagram Twin Application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Piping Diagram Triple Application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Piping Diagram Double Twin Application . . . . . . . . . . . . . . . . . . . . . . . . . . .

20

Wiring diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

24

21
22
23

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

Sound data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Sound Power Spectrum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Sound Pressure Spectrum - Cooling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Sound Pressure Spectrum - Heating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Sound Pressure Spectrum Quiet Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

28

Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

29

Split - Sky Air Outdoor Unit

25
26
27

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29

Operation range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operation Range

Downloaded from www.Manualslib.com manuals search engine

19

Piping diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Installation Method

13

17

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

Wiring Diagrams - Three Phase

11

14

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

Centre of gravity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Centre of Gravity

Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Options

Electrical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Electrical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

3
5

31

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
1

Outdoor Unit Outdoor units optimized for seasonal efficiency RZQSG-LY1

1
ki Sn uU 1 - Yr L o t - o Gi d S l t Q puZ OSR

Features
Seasonal efficiency, optimized for all seasons.

Seasonal efficiency gives an indication on how efficient an air


conditioner operates over an entire heating or cooling season.

The use of inverter type outdoor units results in an air conditioning


system with a high energy efficiency

Re-use of existing R-22 or R-407C technology

Maximum piping length up to 50m, minimum piping length has no


limitation

Daikin outdoor units are neat, sturdy and can easily be mounted on a
roof or terrace or simply placed against an outside wall

Split - Sky Air Outdoor Unit

Downloaded from www.Manualslib.com manuals search engine

Outdoor Unit Outdoor units optimized for seasonal efficiency RZQSG-LY1

Specifications

2-1 Nominal Capacity And Nominal Input


Cooling capacity

Nom.

FCQHG100F/ RZQSG100LY1

FCQHG125F/ RZQSG125LY1

FCQHG140F/ RZQSG140LY1

kW

9.5 (3)

12.0 (3)

13.4 (3)

Heating capacity

Nom.

kW

10.8 (4)

13.5 (4)

15.5 (4)

Power input

Cooling

Nom.

kW

2.57

3.71

4.17

Heating

Nom.

kW

2.51

3.60

4.29

EER

3.70

3.23

3.21

COP

4.30

3.75

3.61

SEER

5.70 (6)

5.21 (6)

SCOP

3.91 (6)

3.81 (6)

1,285

1,855

2,085

Annual energy consumption


Energy label

kWh

Cooling

Heating

2-1 Nominal Capacity And Nominal Input

FCQG100F / RZQSG100LY1

FCQG125F / RZQSG125LY1

FCQG140F / RZQSG140LY1

Cooling capacity

Nom.

kW

9.5 (3)

12.0 (3)

13.4 (3)

Heating capacity

Nom.

kW

10.8 (4)

13.5 (4)

15.5 (4)

Power input

Cooling

Nom.

kW

2.88

3.74

4.45

Heating

Nom.

kW

3.05

3.96

4.54

EER

3.30

3.21

COP

3.54

SEER

5.11 (6)

SCOP
Annual energy consumption
Energy label

kWh

3.80 (6)

3.81 (6)

1,440

1,870

2,225

Cooling

Heating

2-1 Nominal Capacity And Nominal Input

FAQ100C / RZQSG100LY1

Cooling capacity

Nom.

kW

9.5 (3)

Heating capacity

Nom.

kW

10.8 (4)

Power input

Cooling

Nom.

kW

3.16

Heating

Nom.

kW

3.17

EER

3.01

COP

3.41

SEER

4.61 (6)

SCOP

3.81 (6)

Annual energy consumption


Energy label

3.01
3.41

kWh

1,580

Cooling

Heating

2-1 Nominal Capacity And Nominal Input

FVQ100C / RZQSG100LY1

FVQ125C / RZQSG125LY1

FVQ140C / RZQSG140LY1

Cooling capacity

Nom.

kW

9.5 (3)

12.0 (3)

13.4 (3)

Heating capacity

Nom.

kW

10.8 (4)

13.5 (4)

15.5 (4)

Power input

Cooling

Nom.

kW

2.96

4.27

4.45

Heating

Nom.

kW

2.99

3.96

4.54

EER

3.21

2.81

COP

3.61

SEER

5.11 (6)

4.31 (6)

SCOP

3.80 (6)

3.81 (6)

2,135

2,225

Annual energy consumption


Energy label

kWh

1,480

Cooling

3.01
3.41

Heating

Split - Sky Air Outdoor Unit


Downloaded from www.Manualslib.com manuals search engine

B
B

Outdoor Unit Outdoor units optimized for seasonal efficiency RZQSG-LY1

Specifications

2-1 Nominal Capacity And Nominal Input

1
2

FBQ100C8 / RZQSG100LY1

FBQ125C8 / RZQSG125LY1

Cooling capacity

Nom.

kW

9.5 (3)

12.0 (3)

13.4 (3)

Heating capacity

Nom.

kW

10.8 (4)

13.5 (4)

15.5 (4)

Power input

Cooling

Nom.

kW

2.87

3.74

4.44

Heating

Nom.

kW

2.96

3.85

4.54

EER

3.31

3.21

3.02

COP

3.65

3.51

3.41

SEER

5.11 (6)

SCOP
Energy label

4.35 (6)

3.81 (6)

Annual energy consumption

kWh

1,435

Cooling

1,870

2,220

Heating

2-1 Nominal Capacity And Nominal Input

FHQG100C / RZQSG100LY1

FHQG125C / RZQSG125LY1

Cooling capacity

Nom.

kW

9.5 (3)

12.0 (3)

13.4 (3)

Heating capacity

Nom.

kW

10.8 (4)

13.5 (4)

15.5 (4)

Power input

FHQG140C / RZQSG140LY1

Cooling

Nom.

kW

2.96

4.15

4.45

Heating

Nom.

kW

2.99

3.73

4.54

EER

3.21

2.89

3.01

COP

3.61

3.62

3.41

SEER

5.11 (6)

4.61 (6)

SCOP

3.80 (6)

3.81 (6)

1,480

2,075

2,225

Annual energy consumption


Energy label

kWh

Cooling
Heating

2-1 Nominal Capacity And Nominal Input

FDQ125C / RZQSG125LY1

Nom.

kW

12.0 (3)

Heating capacity

Nom.

kW

13.5 (4)
3.74

Cooling

Nom.

kW

Heating

Nom.

kW

EER

3.85
3.21

COP

3.51

SEER

4.35 (6)

SCOP

3.81 (6)

Annual energy consumption


Energy label

kWh

1,870

Cooling

Heating

Notes
(1) Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions)
(2) Energy label: scale from A (most efficient) to G (less efficient)
(3) Cooling: indoor temp. 27CDB, 19CWB; outdoor temp. 35CDB; equivalent piping length: 5m; level difference: 0m
(4) Heating: indoor temp. 20CDB; outdoor temp. 7CDB, 6CWB; equivalent refrigerant piping: 5m; level difference: 0m
(5) Annual energy consumption is according to Energy labeling directive 2002/31/EC
(6) SEER and SCOP are according to EN 14825

Split - Sky Air Outdoor Unit

Downloaded from www.Manualslib.com manuals search engine

B
B

Cooling capacity
Power input

FBQ140C8 / RZQSG140LY1

Outdoor Unit Outdoor units optimized for seasonal efficiency RZQSG-LY1

Specifications

2-2 Technical Specifications


Capacity control
Casing
Dimensions

RZQSG100LY1

Heat exchanger

Colour

Ivory white

Material

Painted galvanized steel plate

Unit

Height

mm

Width

mm

940

Depth

mm

320

Height

mm

Width

mm

Depth

mm

990

1,430

1,170
422

101

Packed unit

kg

94

114

mm

904

mm

1.4

Quantity

Fin pitch
Quantity

Face area

Stages

Quantity

Empty tubeplate
hole

Quantity

12

16

0.87

1.273

44

64
0

Tube type

7 Hi-XSL

Fin

Type

WF fin

Treatment

Anti-corrosion treatment (PE)

Type

Propeller fan

Discharge direction

Horizontal

Quantity
Air flow rate

Fan motor

1,610

82

Passes

Cooling Nom.

m/min

76

Super
low

m/min

cfm

Heating Nom.

m/min

Super
low

m/min

77

83

83

62
-

cfm

Quantity

Model

Brushless DC motor

Output

200

Drive
Speed

94
Direct drive

Steps

Cooling Nom.

rpm

Super
low

rpm

Heating Nom.

rpm

Super
low

rpm

850

855

700

920

540
-

Sound power level

Cooling

Nom.

dBA

69

70

69

Sound pressure level

Cooling

Nom.

dBA

53

54

53

Heating

Nom.

dBA

57

58

54

Night quiet mode

Level 1

dBA

Compressor

49

Quantity

Model

2YC63PXD

Type
W

2,080

2,620

Starting method
Cooling
Heating
Refrigerant

3,620

Inverter driven
Ambient Min.

CDB

-5.0

Max.

CDB

46.0

Ambient Min.

CWB

-15.0

Max.

CWB

15.5

Type

R-410A

Charge

kg

Control
Circuits

2YC90CXD

Hermetically sealed swing compressor

Output
Operation range

1,015

kg

Length

3
2

Unit

Rows

Fan

RZQSG140LY1

Inverter controlled

Packed unit

Weight

RZQSG125LY1

Method

2.9

4.0

Expansion valve (electronic type)


Quantity

Split - Sky Air Outdoor Unit


Downloaded from www.Manualslib.com manuals search engine

Outdoor Unit Outdoor units optimized for seasonal efficiency RZQSG-LY1

Specifications

2-2 Technical Specifications


Refrigerant oil

Type

Piping connections

Liquid

RZQSG100LY1

0.9

Quantity

Flare connection

OD
Gas

mm

9.52

Quantity

Type

Flare connection

OD
Drain

mm

15.9

Quantity

Type

Piping length

1.35
1

Type

Hole

ID

mm

OD

mm

26

OU - IU Min.

Max.

50

System Equiva- m
lent

70

Charge- m
less

30

Additional refrigerant charge

kg/m

Level difference

IU - OU Max.

IU - IU

Max.

See installation manual 4P302555-1


30.0
0.5

Heat insulation

Both liquid and gas pipes

Defrost method

Pressure equalising

Defrost control

Sensor for outdoor heat exchanger temperature

Safety devices

Item

01

High pressure switch

02

Fan motor thermal protection

03

Fuse

2-3 Electrical Specifications


Power supply

RZQSG100LY1

RZQSG125LY1

Name

3N~

Frequency

Hz

50

Voltage

380-415

Voltage range
Zmax

Min.

10

Max.

10

List

Recommended fuses
Wiring connections

RZQSG140LY1

Y1

Phase

Current

RZQSG140LY1

FVC50K

Charged volume

RZQSG125LY1

Complies to EN61000-3-11
A

20

25

For power supply

Remark

See installation manual 4P302555-1

For connection with


indoor

Remark

See installation manual 4P302555-1

Power supply intake


Notes

Outdoor unit only

(1) PED: assembly = category l : excluded from scope of PED due to article 1, item 3.6 of 97/23/EC
(2) See separate drawing for electrical data
(3) Equipment complying with EN/IEC 61000-3-12: European/international technical standard setting the limits for harmonic currents produced by equipment connected to public lowvoltage system with input current \> 16A and 75A per phase
(4) Short-circuit power
(5) See separate drawings for electrical data
(6) European/international technical standard setting the limits for harmonic currents produced by equipment connected to public low-voltage system with input current larger than 16A
and 75A per phase.
(7) Related to 3D076918

Split - Sky Air Outdoor Unit

Downloaded from www.Manualslib.com manuals search engine

Outdoor Unit Outdoor units optimized for seasonal efficiency RZQSG-LY1

Electrical data

3-1

Electrical Data

1
3

Split - Sky Air Outdoor Unit


Downloaded from www.Manualslib.com manuals search engine

Outdoor Unit Outdoor units optimized for seasonal efficiency RZQSG-LY1

Electrical data

3-1

Electrical Data

1
3

Split - Sky Air Outdoor Unit

Downloaded from www.Manualslib.com manuals search engine

Outdoor Unit Outdoor units optimized for seasonal efficiency RZQSG-LY1

Options

4-1

Options

3
1
4

Split - Sky Air Outdoor Unit


Downloaded from www.Manualslib.com manuals search engine

Outdoor Unit Outdoor units optimized for seasonal efficiency RZQSG-LY1

Combination table

5-1

Combination Table

1
5

10

Split - Sky Air Outdoor Unit

Downloaded from www.Manualslib.com manuals search engine

Outdoor Unit Outdoor units optimized for seasonal efficiency RZQSG-LY1

Capacity tables

6-1

Cooling Capacity Tables

3
1
6

Split - Sky Air Outdoor Unit


Downloaded from www.Manualslib.com manuals search engine

11

Outdoor Unit Outdoor units optimized for seasonal efficiency RZQSG-LY1

Capacity tables

6-1

Cooling Capacity Tables

1
6

12

Split - Sky Air Outdoor Unit

Downloaded from www.Manualslib.com manuals search engine

Outdoor Unit Outdoor units optimized for seasonal efficiency RZQSG-LY1

Capacity tables

6-1

Cooling Capacity Tables

3
1
6

Split - Sky Air Outdoor Unit


Downloaded from www.Manualslib.com manuals search engine

13

Outdoor Unit Outdoor units optimized for seasonal efficiency RZQSG-LY1

Capacity tables

6-2

Heating Capacity Tables

1
6

14

Split - Sky Air Outdoor Unit

Downloaded from www.Manualslib.com manuals search engine

Outdoor Unit Outdoor units optimized for seasonal efficiency RZQSG-LY1

Capacity tables

6-2

Heating Capacity Tables

3
1
6

Split - Sky Air Outdoor Unit


Downloaded from www.Manualslib.com manuals search engine

15

Outdoor Unit Outdoor units optimized for seasonal efficiency RZQSG-LY1

Capacity tables

6-2

Heating Capacity Tables

1
6

16

Split - Sky Air Outdoor Unit

Downloaded from www.Manualslib.com manuals search engine

Outdoor Unit Outdoor units optimized for seasonal efficiency RZQSG-LY1

Capacity tables

6-3

Capacity Correction Factor

3
1
6

Split - Sky Air Outdoor Unit


Downloaded from www.Manualslib.com manuals search engine

17

Outdoor Unit Outdoor units optimized for seasonal efficiency RZQSG-LY1

Dimensional drawings

7-1

Dimensional Drawings

1
7

18

Split - Sky Air Outdoor Unit

Downloaded from www.Manualslib.com manuals search engine

Outdoor Unit Outdoor units optimized for seasonal efficiency RZQSG-LY1

Centre of gravity

8-1

Centre of Gravity

3
1
8

Split - Sky Air Outdoor Unit


Downloaded from www.Manualslib.com manuals search engine

19

Outdoor Unit Outdoor units optimized for seasonal efficiency RZQSG-LY1

Piping diagrams

9-1

Piping Diagrams

1
9

20

Split - Sky Air Outdoor Unit

Downloaded from www.Manualslib.com manuals search engine

Outdoor Unit Outdoor units optimized for seasonal efficiency RZQSG-LY1

Piping diagrams

9-2

Piping Diagram Twin Application

3
1
9

Split - Sky Air Outdoor Unit


Downloaded from www.Manualslib.com manuals search engine

21

Outdoor Unit Outdoor units optimized for seasonal efficiency RZQSG-LY1

Piping diagrams

9-3

Piping Diagram Triple Application

1
9

22

Split - Sky Air Outdoor Unit

Downloaded from www.Manualslib.com manuals search engine

Outdoor Unit Outdoor units optimized for seasonal efficiency RZQSG-LY1

Piping diagrams

9-4

Piping Diagram Double Twin Application

3
1
9

Split - Sky Air Outdoor Unit


Downloaded from www.Manualslib.com manuals search engine

23

Outdoor Unit Outdoor units optimized for seasonal efficiency RZQSG-LY1

10

Wiring diagrams

10 - 1 Wiring Diagrams - Three Phase

1
10

24

Split - Sky Air Outdoor Unit

Downloaded from www.Manualslib.com manuals search engine

Outdoor Unit Outdoor units optimized for seasonal efficiency RZQSG-LY1

11

Sound data

11 - 1 Sound Power Spectrum

3
1
11

Split - Sky Air Outdoor Unit


Downloaded from www.Manualslib.com manuals search engine

25

Outdoor Unit Outdoor units optimized for seasonal efficiency RZQSG-LY1

11

Sound data

11 - 2 Sound Pressure Spectrum - Cooling

1
11

26

Split - Sky Air Outdoor Unit

Downloaded from www.Manualslib.com manuals search engine

Outdoor Unit Outdoor units optimized for seasonal efficiency RZQSG-LY1

11

Sound data

11 - 3 Sound Pressure Spectrum - Heating

3
1
11

Split - Sky Air Outdoor Unit


Downloaded from www.Manualslib.com manuals search engine

27

Outdoor Unit Outdoor units optimized for seasonal efficiency RZQSG-LY1

11

Sound data

11 - 4 Sound Pressure Spectrum Quiet Mode

1
11

28

Split - Sky Air Outdoor Unit

Downloaded from www.Manualslib.com manuals search engine

Outdoor Unit Outdoor units optimized for seasonal efficiency RZQSG-LY1

12

Installation

12 - 1 Installation Method

3
1
12

Split - Sky Air Outdoor Unit


Downloaded from www.Manualslib.com manuals search engine

29

Outdoor Unit Outdoor units optimized for seasonal efficiency RZQSG-LY1

12

Installation

12 - 1 Installation Method

1
12

30

Split - Sky Air Outdoor Unit

Downloaded from www.Manualslib.com manuals search engine

Outdoor Unit Outdoor units optimized for seasonal efficiency RZQSG-LY1

13

Operation range

13 - 1 Operation Range

3
1
13

Split - Sky Air Outdoor Unit


Downloaded from www.Manualslib.com manuals search engine

31

Please fill out the requested information


Please fill out the requested information

Daikin Europe N.V. participates in the Eurovent


Certification programme for Air conditioners (AC),
Liquid Chilling Packages (LCP), Air handling units
(AHU) and Fan coil units (FCU), Check ongoing validity
of certificate online: www.eurovent-certification.com
or using: www.certiflash.com

Daikin products are distributed by:

The present leaflet is drawn up by way of information only and does not
constitute an offer binding upon Daikin Europe N.V.. Daikin Europe N.V. has
compiled the content of this leaflet to the best of its knowledge. No express
or implied warranty is given for the completeness, accuracy, reliability or fitness
for particular purpose of its content and the products and services presented
therein. Specifications are subject to change without prior notice. Daikin Europe
N.V. explicitly rejects any liability for any direct or indirect damage, in the
broadest sense, arising from or related to the use and/or interpretation of this
leaflet. All content is copyrighted by Daikin Europe N.V.

EEDEN1 2 - 1 0 0

Naamloze Vennootschap - Zandvoordestraat 300, B-8400 Oostende - Belgium - www.daikin.eu - BE 0412 120 336 - RPR Oostende

Downloaded from www.Manualslib.com manuals search engine

EEDEN12-100 04/12 Copyright Daikin


The present publication supersedes EEDEN11-100
Printed on non-chlorinated paper. Prepared by Goekint Graphics NV, Belgium
Responsible Editor: Daikin Europe N.V., Zandvoordestraat 300, B-8400 Oostende

Daikins unique position as a manufacturer of air


conditioning equipment, compressors and refrigerants
has led to its close involvement in environmental issues.
For several years Daikin has had the intention to become
a leader in the provision of products that have limited
impact on the environment. This challenge demands the
eco design and development of a wide range of products
and an energy management system, resulting in energy
conservation and a reduction of waste.

You might also like