Professional Documents
Culture Documents
www.lcautomation.com
Safety switches www.lcautomation.com
20 years
Protection . . . . . . . . . . . . . . . . . . . . IP67
Mission Time
25 million
Dimensions . . . . . . h26 x w36 x d13mm
B10d value
BNS260 coded magnetic safety
switches are designed for use in
machinery which needs a constant Cable Connection Plug Connection
stop cycle for human intervention Order List Order List
of the machine cycle. Contacts Guards Code Price Code Price
1 NC/1 NO Left hand BNS260-11/01ZG-L 52.03 BNS260-11/01ZG-ST-L 59.22
1 NC/1 NO Right hand BNS260-11/01ZG-R 52.03 BNS260-11/01ZG-ST-R 59.22
2 NC Left hand BNS260-02/01ZG-L 52.03 BNS260-02/01ZG-ST-L 49.93
2 NC Right hand BNS260-02/01ZG-R 52.03 BNS260-02/01ZG-ST-R 49.93
. . . for
recommended
Accessories
SRB series
List
safety relays
Description Order Code Price
Actuator BPS260-1 5.84
See page Actuator 90 fixing BPS260-2 5.84
492 5m connection cable with M8 6-pin plug 101206011 21.31
List
Description Order Code Price
Standard coding RSS260-D-ST 77.35
RST16-1 Sliding door actuator
Individual coding with teach RSS260-I2-D-ST 111.23
Actuators
List
Description Order Code Price
RST-U-2 Plexiglass door actuator Sliding door actuator RST16-1 12.60
Plexiglass door actuator RST-U-2 12.60
Swivel door frame actuator RST260-1 12.60
Accessories
List
Description Order Code Price
Cable with M8, 8-pin connector, 2m A-K8P-M8-S-G-2M-BK-2-X-A-4 21.58
Cable with M8, 8-pin connector, 5m A-K8P-M8-S-G-5M-BK-2-X-A-4 30.47
RST260-1 Swivel door frame actuator
Technical
technical support engineers
for free expert technical advice
Support? Blackburn
01254 685900
www.lcautomation.com
Check latest prices and stock availability @ www.lcautomation.com 515
Safety switches www.lcautomation.com
PLe
Housing material . . . . . . . . Thermoplastic
EN ISO 13849-1 Performance Level
SIL CL 3
Protection . . . . . . . . . . . . . . . . IP65/IP67
EN 62061 SIL Claim
Dimensions . . . . . . h91 x w52 x d30mm
Cat 4
tampering is essential.
EN 954-1 Category
misalignment and boundary area
PLe
indication
EN ISO 13849-1 Performance Level
= High level of reliability due to shock
The safety switch determines which
actuator code to use and will not
and vibration resistance EN 62061 SIL Claim SIL CL 3
engage unless the proper code is read.
They offer a cost-effective series Multicoded Unique coded
connection of up to 30 switches and Safe Safe Order List Order List
Connection Switch On Switch Off Code Price Code Price
0.2m cable with plug 15mm 25mm TR4-SAM01C 79.58 TR4-SAU01C 109.18
ensure reliable monitoring of multiple
3m cable 15mm 25mm TR4-SAM03P 79.58 TR4-SAU03P 109.18
access installations with full diagnostic
coverage of individual faults.
BNS40S-12Z-C List
Description Order Code Price
Magnetic safety switch BNS40S-12Z 87.20
Magnetic safety switch with LED BNS40S-12ZG 91.87
Actuator (stainless steel) mounting level BPS40S-1 21.79
Actuator (stainless steel) 90 attached to sensor BPS40S-2 21.79
EX-BNS40S
. . . for
certified
recommended
List
SRB series
Description Order Code Price
Magnetic safety switch with concealed holes EX-BNS40S-12Z-C 140.47
safety relays
Magnetic safety switch with concealed holes, 5m cable EX-BNS40S-12Z-C-5M 154.50
See page Actuator (stainless steel) mounting level BPS40S-1-C 21.79
492 Actuator (stainless steel) 90 attached to sensor BPS40S-2-C 21.79
RE1
RE1/RE2 magnetic safety switches
are equipped with either normally Safe Safe List
Contacts Connection Switch on Switch off Order Code Price
1 NO/1 NC 5m cable 3mm 12mm RE11-SA05 31.22
closed (NC) or normally open
1 NO/1 NC M8 plug, 4 pin 3mm 12mm RE11-SAC 34.84
(NO) contacts respectively and use
2 NO 5m cable 7mm 20mm RE13-SA05 30.88
coded magnetic actuators.
They are easy to clean, making them 2 NO M8 plug, 4 pin 7mm 20mm RE13-SAC 34.82
suitable for contaminated areas or
environments with strict hygiene RE2
standards. Safe Safe Status List
Their operating principle enables Contacts Connection Switch on Switch off Display Order Code Price
greater tolerances, making them ideal 1 NO/1 NC 5m cable 6mm 31mm RE21-SA05 29.52
for applications where precise 1 NO/1 NC M8 plug, 4 pin 6mm 31mm RE21-SAC 30.23
guidance is difficult. 3 NO 5m cable 9mm 20mm l RE27-SA05L 36.96
3 NO 10m cable 9mm 20mm l RE27-SA10L 42.75
Technical
technical support engineers
for free expert technical advice
Support? Blackburn
01254 685900
www.lcautomation.com
Check latest prices and stock availability @ www.lcautomation.com 519
Safety switches www.lcautomation.com
IN3000 Direct
Cylindrical non-contact inductive safety switch
Features Technical specification
= Direct connection to safe control PFHd . . . . . . . 1.0 x 10-7 (EN ISO 13849)
solution possible
= Response range of up to 15mm
Type of output . . . . . . . . Semiconductor
. . . for
Flexible Dimensions . . . . . . . . h70 x w52 x d30mm
. . . for
Dimensions . . . . . . . . h90 x w52 x d30mm
Flexible
Features
= Compact plastic housing
= Rigid or mobile actuators
= 3 x M20 x 1.5 cable entry glands List
= Slow-action switching elements with
Description Contacts Order Code Price
3 contacts Safety switch with separate actuator 2 NC/1 NO i17-SA213 23.38
= IP67 enclosure rating
Actuators and accessories
Design Actuation Option Minimum Door Radius Order Code List Price
Straight Rigid 175mm iE17-S1 4.79
REMINDER Radial Fully flexible 60mm iE16-F1 13.28
Radial Semi flexible 60mm iE16-F2 8.41
Please remember that you will
Catch and retainer kit iE16-SCR 7.54
need to purchase the actuator
M20 cable gland, black 5309164 1.15
3 x 106
No. of positive action N/C
B10d value
Type 2
solenoid monitoring contacts . . . . . 2/1
EN ISO 14119
(depending on type)
No. of N/O solenoid monitoring
REMINDER
contacts . . . . . . 1/0 (depending on type)
No. of positive actions N/C door
monitoring contacts . . . . . . . . . . . 0/1/2
Please remember that you will
Features (depending on type)
= Narrow plastic housing No. of door monitoring contacts need to purchase the actuator
= Rigid or mobile actuators N/O . . . . . . . . .0/1 (depending on type)
= Available with M20 x 1.5 cable entry N/C . . . . . . . . .1/0 (depending on type)
glands or Flexi Loop compatible
M12 plug connector (depending
on variant)
= Locked by spring force and
magnetic force
= Lock and door monitoring
Actuators
Minimum List
Design Actuator Option Method of Actuation Door Radius Order Code Price
Straight Rubber mounted 1000mm iE10-S2 5.23
Angled Rigid With overtravel 1000mm iE10-A4 3.84
Radial Semi flexible Door hinged at top/bottom 90mm iE10-R1 11.64
Radial Semi flexible Door hinged at left/right 100mm iE10-R2 9.52
Actuator
Minimum List
Design Actuator Option Method of Actuation Door Radius Order Code Price
Straight Rigid Catch & retainer set for increased retaining force 160mm iE14-S1 5.94
If you can't find what you need, just call sales & ask!
Blackburn Chippenham
01254 685900 01249 460099
www.lcautomation.com
526 Call Blackburn 01254 685900 or Chippenham 01249 460099
www.lcautomation.com Safety switches
Accessories
List
Description Actuator Option Minimum Door Radius Order Code Price
Straight actuator Rigid 160mm iE200-S1 5.71
Radial actuator Fully flexible 80mm iE200-F1 14.94
Bolt actuator straight Rigid 175mm iE200-B1 101.37
M20 cable gland, black 5309164 1.15
. . . for
Auxiliary contacts . . . . . . . . . . . . . . . . . 2
recommended See
Safety contacts . . . . . . . . . . . . . . . . . . . 4
492
Power consumption . . . . . . . . max 10W
safety relays Actuator contacts . . . . . . . 1 NO + 2 NC
Straight Flexible Solenoid contacts . . . . . . . 1 NO + 2 NC
power to unlock
Contact ratings
AC-15 . . . . . . . . . . . . . . . . . 4A 230V a.c.
The AZM161 is designed for Power to lock versions are also DC-13 . . . . . . . . . . . . . . . . 2.5A 24V d.c.
installations such as machines or available, please call our head office Protection rating . . . . . . . . . . . . . . . . IP67
robot cells where access to the sales department on 01254 685900 Dimensions . . . . . h130 x w90 x d30mm
20 years
hazard is to be controlled until a safe for further details.
Mission Time
2 million
condition exists on the machine.
B10d value
The device can be unlocked when
power is applied to the solenoid.
This signal can be initiated by a timer List
Description Order Code Price
or a standstill monitoring device.
2 NC/1 NO actuator, 2 NC/1 NO solenoid AZM161SK-12/12RK-024 152.67
The power to unlock version is a
common mode of operation for this Straight actuator AZM161-B1 7.51
application. Flexible actuator AZM161-B6 21.02
www.lcautomation.com
Addresses My Account My Orders My Quotes My Buying Lists User Password Newsletter Sign up
. . . for
Contact ratings
recommended See
AC-15 . . . . . . . . . . . . . . . . . 4A 230V a.c.
= M12 connection
Inputs . . . . 2 safety inputs for series wiring
Diagnostic display . . . . . . . . . . . . 3 LEDs
for condition status
Ambient temperature . . . -25 to +60C
Dimensions . . . . . h220 x w40 x d50mm
Cat 4
operation.
EN 954-1 Category
EN ISO 13849-1 Performance Level PLe
SIL CL 3
Features
= Hygiene compliant design, resistant EN 62061 SIL Claim
Accessories
List
Description Order Code Price
Straight actuator AZM400-B1 55.16
Mounting bracket MS-AZM400 28.19
Cable with M12, 8-pin connector, 2.5m A-K8P-M12-S-G-2.5M-BK-1-X-A-2 30.84
Straight actuator Cable with M12, 8-pin connector, 5m A-K8P-M12-S-G-5M-BK-1-X-A2 32.78
7.3 million
The mechanical safety switch for use in a variety of applications B10d value
= Housing is dust-tight, insensitive to
PSENmech is suitable for safe
Safety switch for monitoring the position of
monitoring and locking of movable dirt and waterproof movable guards in accordance with EN 60947-5-3
guards which must not be opened
until a safe state has been achieved
(such as the hazardous moving
parts coming to a standstill).
Power to release with auxiliary release
(complete unit including actuator) Standard Actuator Radius Actuator
Ident List Ident List
Supply Voltage No Order Code Price No Order Code Price
24V a.c./d.c. 570000 PSENme 1S/1AS 99.88 570001 PSENme 1S/1AR 127.62
110-230V a.c. 570006 PSENme 1.2S/1AS 142.59 570007 PSENme 1.2S/1AR 163.68
Power to lock
(complete unit including actuator) Standard Actuator Radius Actuator
Ident List Ident List
Supply Voltage No Order Code Price No Order Code Price
24V a.c./d.c. 570004 PSENme 1M/1AS 105.43 570005 PSENme 1M/1AR 134.10
Technical
technical support engineers
for free expert technical advice
Support? Blackburn
01254 685900
www.lcautomation.com
Check latest prices and stock availability @ www.lcautomation.com 533
Safety switches www.lcautomation.com
List
Fixing kits Contacts Order Code Price
1 NO/1 NC ZQ700-11 71.38
2 NC ZQ700-02 71.38
www.lcautomation.com
534 Call Blackburn 01254 685900 or Chippenham 01249 460099
www.lcautomation.com Safety switches
ZQ900-11N
. . . for recommended See page
SRB series safety relays 492
Contacts Order Code List Price Order Code List Price Order Code List Price
1 NO/1 NC ZQ900-11 124.46 ZQ900-11N 164.81
1 NO/3 NC ZQ900-13 151.86 ZQ900-13N 184.10
2 NO/2 NC ZQ900-22 143.77 ZQ900-22N 184.10 EX-ZQ900-22-3D 220.19
2 NC ZQ900-02 124.46 ZQ900-02N 173.86
4 NC ZQ900-04 148.05 ZQ900-04N 194.55 EX-ZQ900-04-3D 239.20
Fixing kits
Fixing kits
= 1 x wire rope List
Fixing kits contain:
= Metal enclosure
Contact rating
AC-15 . . . . . . . . . . . . . . 4A, 230V a.c.
= Protective shield with wide opening DC-13 . . . . . . . . . . . . . . . 1A, 24V d.c.
= Low pedal height Cable entry . . . . . . . . . . . . . . . . . . M20
= High level of stability Connection type . . . . . . Screw terminals
Ambient temperature . . . -25 to +60C
Protection . . . . . . . . . . . . . . . . . . . . IP65
List
Switching Contacts Order Code Price
1 NO/1 NC TFH 232-11UEDR 155.74
2 NO/2 NC TFH 232-22UEDR 170.23
Over 10,000
products
available to buy
online with all
the information
and support
you need
Log-on today!
www.lcautomation.com
Safety switches www.lcautomation.com
EXTRACTED
proBody Unit
Key Adapter
Key Adapter
Key Adapter
Release Unit
proOptions
Lok Body
Actuator
ACCESS
proBody
SAFETY
Internal
Options
Head
M A 4 M 6 0 0 0 0 0 0 0 0 0 0 0 A K L 1 1 L L C 0 1 L 0 1 3 6 2 N
MA M 6
Option 2 proAT Tongue, proSlidebars and proHandles for use with proAT Heads
proAT TONGUE proSLIDEBARS proHANDLES proAT HEADS
Order Code
TN
125.00 Order Code Order Code
EN T6
without spring
29.00
Order Code Order Code Order Code
TI EH T7
125.00 with internal handle 167.00 with lock out 94.00
with internal handle
ENTRY POSITION
Choose from the options listed below (leave the order code blank if the option is not required)
Internal release units for use with proAM handle (MI), proSlidebar (TI) and proHandle (EH)
INTERNAL RELEASE UNIT
A K L 1 1
Example Example Example
Order Code Order Code Order Code
EKR7 SKL81 AKL11
163.00 164.00 91.00
For increased safety the extract key This unit ensures that the machine/ This unit is ideally suited for authorised
adapter performs the same function as process cannot be restarted without access only or linked to other
a safety key, but must be removed returning the key(s). machinery.
S K L 0 0 A K L 0 0
from the lock to gain access. Only one
extract key can be used on any lock.
E K R 0
L Standard lock L Standard lock
R Releasing lock R Releasing lock
(must be used if a PushIR or EI handle and head are used) (must be used if a PushIR or EI handle and head are used)
S K L 1 0 A K L 1 0
L Standard lock
R Releasing lock
(must be used if a PushIR or EI handle and head are used)
S K L 1 1 A K L 1 1
2 Standard lock + dustcover
3 Standard lock + padlockable dustcover
Example order code: Extracted key adapter with
1-9 No. of safety lock adapters required 1-9 No. of safety lock adapters required
releasing lock and dustcover
standard lock and padlockable dustcover. 1 safety standard lock. 1 safety lock adaptor is required.
Example order code: Safety key adapter with Example order code: Access key adapter with
lock adaptor is required.
C L K - S U S
Order Code
CLK-SUS PLEASE REMEMBER
22.00
ACCESSORIES
Standard Key
TO ORDER YOUR KEYS
L L
Order Code Order Code Order Code Order Code Order Code
SL LL ST EX FT
260.00 349.00 105.00 433.00 6.00
S L L 8 1 L L L 8 1 S T L 8 1 E X L 8 1 F T L 8 1
proLok Body proLok+ Body proStop Body proStopEX Body proStop Foot
SL Short body LL Long body ST Stop body EX Explosion stop body FT To terminate
SR Releasing short body LR Releasing long body non-switch
(must be used if a PushIR or (must be used if a PushIR or EI configurations
EI handle and head are used) handle and head are used)
STEP 6 STEP 7
The above pricing is based on the 24V proBody option
VOLTAGE UNIT
L L C 8 1 C L 0 1 8 1 1 N L 0
L0 proLok+Body switch information
1
0 No voltage (e.g. Foot)
110V
PUSHBUTTON/LAMPS
L 0 1 3 6 2 1 1 3 6 2
2 230V
4 24V
5 100V
1
6 115V 0 Blank
7 48V Red Lamp
2 Yellow Lamp
S 110V Solenoid/24V Control (Lok only)
3 Green Lamp
C 110V Control/24V Solenoid (Lok only) 6 Blue Lamp
7 White Lamp
OVERRIDE E E-stop (twist reset)
L L C 1 1 1
H E-stop (twist reset + additional monitoring contacts)
P E-stop (pull reset)
1 3
U E-stop (illuminated twist reset)
1
0 Stop/EXP/UXP L Latching selector switch (illuminated)
Key reset M Momentary selector switch (illuminated)
6 2
2 Knob reset V Latching selector switch (illuminated)
A Latching key switch (90)
3 Screwdriver reset
R Red illuminated pushbutton (non-latching)
Y Yellow illuminated pushbutton (non-latching)
PCB G Green illuminated pushbutton (non-latching)
L L C 1 1 1
B Blue illuminated pushbutton (non-latching)
W White illuminated pushbutton (non-latching)
K Black non-illuminated pushbutton (non-latching)
1 Standard & sourcing
SWITCHES
PLEASE REMEMBER L 0 1 3 6 2 N N
N No addtional switches are required
TO ORDER YOUR KEYS
Please remember
ENGRAVING DETAILS: Each key combination has an engraved code on the to supply your
lock and key (maximum 3 lines of 10 characters), the code is used to identify the engraving details
locks and keys and is recorded in a database for continuous cross reference. with each order
List
Control Voltage Order Code Price
24V a.c./d.c. TA2T6ST401 190.00
110V a.c. TA2T6ST101 190.00
Tongue operated
Accessories
safety gate switch Description Order Code List Price
with safety key or access key Standard key (each) CLK-SUS 22.00
Please remember
ENGRAVING DETAILS: Each key combination has an engraved code on the to supply your
lock and key (maximum 3 lines of 10 characters), the code is used to identify the engraving details
locks and keys and is recorded in a database for continuous cross reference. with each order
Please remember
ENGRAVING DETAILS: Each key combination has an engraved code on the to supply your
lock and key (maximum 3 lines of 10 characters), the code is used to identify the engraving details
locks and keys and is recorded in a database for continuous cross reference. with each order
PLe
specific requirements with no or short run-down cycles
= To be used with safety relay or EN ISO 13849-1 Performance Level
safety PLC control system B10d value 5 million
List
Control Voltage Order Code Price
24V a.c./d.c. MA2M6ST401 199.00
110V a.c. MA2M6ST101 199.00
Please remember
ENGRAVING DETAILS: Each key combination has an engraved code on the to supply your
lock and key (maximum 3 lines of 10 characters), the code is used to identify the engraving details
locks and keys and is recorded in a database for continuous cross reference. with each order
along with LED status indicators. Tongue operated guard interlock S40-SA2-S6-ST401 207.00
What is mGard?
mGard is the premier range of modular robust trapped key interlocks for
heavy duty applications.
Trapped key interlocking is a tried It is called Trapped Key as it works The principles of trapped key
and tested method of mechanically by releasing and trapping keys in a technology apply to all industries
safeguarding dangerous machines predetermined sequence. After the where it is essential that all energy
and hazardous processes, and is control or power has been isolated, sources are isolated before gaining
suitable for use up to SIL3 (EN/IEC a key is released that can be used access to machinery. Almost all safety
62061) Category 4 and PLe to grant access to individual or issues can simply be solved by
(EN/ISO 13849-1). multiple doors. selecting the required products in
order of the steps shown below:
1 Power/control isolation Identify the energy sources to Identify the type and number
Power/control isolation
Key exchange
be isolated and/or any hazard of access points.
that cannot immediately be = Key exchange units
isolated such as; heat, = Key exchange units with switch
pressure, radiation or machine Because of the modular
rundown time arrangement of mGard both
Power isolation key exchange and door lock
= Mechanical bolt interlock units can easily be extended
= Bolt interlock with limit switch with an extension module
= Bolt interlock with switch
SE-CLIN-A02022 (XMA), for instance when
= Circuit breaker locks doors are added to the
safeguarded area or machine.
2 Key exchange
Control isolation
= Key switches The Fortress Trapped Key
= Solenoid controlled key switch
System allows the safeguarding
= ATEX key switch
of potentially hazardous areas
= ATEX solenoid controlled
without the need for wiring.
key switch All Fortress Interlocks rotary
= Solenoid controlled key switches have European,
switch unit Canadian, Chinese and North
= Electronic time delay unit American approvals.
= Voltage sensing unit
= Knob and key operated switch
control unit
XM4-MLIN
ENGRAVING DETAILS
Identify the type of access Each key combination has an
Door locks and actuators
point; part body or full body engraved code on the lock and
access doors with or without key (maximum 3 lines of 10
Application Examples
1 SS1-CLIN-A02022D024B
After remote request for access and/or
rundown time, the solenoid of the SS1
solenoid controlled key switch is
energised, releasing the key. After
releasing the isolation key, the machine
is isolated.
2 XM3-CLIN 2
3 3 1
The isolation key can be inserted into
the XM3 key exchange box to release
two access keys.
3 DM1-CLIN-H & DM2-CLIN-H
The access keys can be used to open
the doors to the safeguarded area.
Full body access doors are equipped
with a safety key that can be taken into
the safeguarded area, to prevent
Power isolation
Accessories
List
Please remember to supply your
Description Order Code Price
engraving details with each order Standard key (each) CLK-SUS 22.00
Control isolation
S Panel mounted
Without dustcover With dustcover
SR Enclosure
Without dustcover With dustcover
SR Enclosure
Switching List List
Contacts Order Code Price Order Code Price
These units are suitable for 2 NO/2 NC SR-CLIN-A02022 227.00 SR-CLIS-A02022 254.00
isolation or switching current and 4 NO SR-CLIN-A02040 227.00 SR-CLIS-A02040 254.00
may be used to isolate power to
machinery. Accessories
List
Description Order Code Price
Standard key (each) CLK-SUS 22.00
Control isolation
Accessories
List
Description Order Code Price
Standard key (each) CLK-SUS 22.00
Control isolation
5 million
Locks Order Code Price Order Code Price
B10d value
1 ODL1-CLIN-H1CMFA02022 406.00 ODL1-CLIS-H1CMFA02022 462.00
2 ODL2-CLIN-H1CMFA02022 498.00 ODL2-CLIS-H1CMFA02022 582.00
ENGRAVING DETAILS: Each key 3 ODL3-CLIN-H1CMFA02022 590.00 ODL3-CLIS-H1CMFA02022 702.00
combination has an engraved code 4 ODL4-CLIN-H1CMFA02022 682.00 ODL4-CLIS-H1CMFA02022 822.00
on the lock and key (maximum 3 5 ODL5-CLIN-H1CMFA02022 774.00 ODL5-CLIS-H1CMFA02022 942.00
lines of 10 characters), the code is 6 ODL6-CLIN-H1CMFA02022 866.00 ODL6-CLIS-H1CMFA02022 1,062.00
used to identify the locks and keys Accessories
and is recorded in a database for
List
continuous cross reference. Description Order Code Price
Standard key (each) CLK-SUS 22.00
Order Code
PLEASE REMEMBER CLK-SUS
22.00
Please remember to supply your
engraving details with each order
TO ORDER YOUR KEYS
Key exchange
Door locks
DM 2 - C L I N
No.of
Locks Order Code Price Order Code Price
1 DM1-CLIN 146.00 DM1-CLIS 174.00
260.00 2 DM2-CLIN 260.00 DM2-CLIS 315.00
3 DM3-CLIN 374.00 DM3-CLIS 457.00
STEP 2 4 DM4-CLIN 489.00 DM4-CLIS 599.00
Select: The actuator required 5 DM5- CLIN 603.00 DM5-CLIS 741.00
- A
6 DM6-CLIN 717.00 DM6-CLIS 882.00
7 DM7-CLIN 831.00 DM7-CLIS 1,024.00
42.00 8 DM8-CLIN 946.00 DM8-CLIS 1,166.00
9 DM9-CLIN 1,060.00 DM9-CLIS 1,308.00
STEP 3 10 DM10-CLIN 1,174.00 DM10-CLIS 1,450.00
Select: No. of keys required
C L K - S U S X1
DMS Stainless Steel
Without dustcover With dustcover
22.00
No.of List List
TOTAL PRICE: 324.00 Locks Order Code Price Order Code Price
1 DMS1-CLSN 220.00 DMS1-CLSS 248.00
2 DMS2-CLSN 398.00 DMS2-CLSS 454.00
DM2-CLIN-A = Standard door interlock with
Key
Description Order Code List Price
Standard key (each) CLK-SUS 22.00
Please remember to supply your
engraving details with each order
Door locks
ORDER CODE EXAMPLE Forced safety key extraction door interlocks stainless steel
STEP 1 List
Select: The door lock required
No. of Locks Order Code Price
2 DMS2E-CLIS 452.00
DM S 3 E - C L I S 3 DMS3E-CLIS 594.00
594.00 4 DMS4E-CLIS 736.00
5 DMS5E-CLIS 877.00
STEP 2
Select: The actuator required Actuators
- A Description Order Code
List
Price
42.00 Fixed actuator DM-F 42.00
Self aligning actuator DM-S 42.00
STEP 3 Compressible actuator DM-C 42.00
Select: No. of keys required Handle operated actuator DM-H 42.00
22.00
Key
TOTAL PRICE: 658.00
List
DMS3E-CLIS-A = Stainless steel forced safety Description Order Code Price
key extraction door interlock with 3 locks, Standard key (each) CLK-SUS 22.00
supplied with a dustcover and with a spring
loaded handle operated actuator + CLK-SUS
1 x standard key.
Door locks
List
Lock Type Order Code Price
The DMSK is a robust interlock
Hygienic single door interlock with dustcover DMSK-CLSS 248.00
intended for hygienic areas and
suitable for all types of doors. Key
List
Description Order Code Price
PLEASE REMEMBER
Standard key (each) CLK-SUS 22.00
TO ORDER YOUR KEYS
Door actuators
Self aligning
= Ideal for small radius hinged doors
= Horizontal adjustment: 7.50mm
= Vertical adjustment: 3.75mm Compressible Handle operated Spring loaded
= Rotational adjustment any angle List
in 360 Description Order Code Price
Fixed actuator DM-F 42.00
Self aligning actuator DM-S 42.00
Compressible
= Absorbs vibration on hatches/doors
Compressible actuator DM-C 42.00
= Can be used on small radius
Handle operated actuator DM-H 42.00
Spring loaded handle operated actuator DM-A 42.00
hinged doors
= Suitable for situations where the
door is likely to be slammed
Accessories
Handle operated List
= Overcomes misalignment
Description Order Code Price
= Detent hold actuator in place when Lock-out scissor hasp LOS3 19.00
the door is open Key CLK-SUS 22.00
Quick Disconnects
Features
= Robust metal construction
or Trailing Cables
Pushbuttons
= Modular design with 1 to 10
as standard Illuminating and non-illuminating elements
elements
= Safety gate switches
LED Lamps
= Trapped key interlocks Selector Switches
= Operator control options Illuminating and non-illuminating
= Easy to configure and install 2 position & 3 position
= Safety compliant
Selector Key Switch
2 position
Pushbutton
pushbutton
pushbutton
Illuminated
Illuminated
Controlled
Connector
2 Position
Actuator
Self-wire
Solenoid
Selector
Element
Re-start
Internal
(Green)
(White)
Release
Lock &
Switch
Switch
Switch
Safety
(Red)
Head
Start
T A F T HM T R X T A B T S MD L T S R T P 1 T P 3 T P W T 2 A T W 3
T H E
T H E R X A B A B S M D L S R P 1 P 3 P W 2 A W 3
T H E
T H M T H M T H M T H M T H M
+ + + + +
Order Code Order Code Order Code Order Code Order Code
THF T A F THH THS THE THN
T A H T A S T E H
14.00 28.00 28.00 67.00 54.00 T E N
R X
Order Code Order Code
RX RZ
68.00 90.00
Standard 60mm internal release Variable length internal release
Note: You must select safety contacts to go with this unit from the safety switches and solenoid section
SAFETY ACCESS
A B
Order Code
Order Code Order Code Order Code QB
SN GN AB 62.00
49.00 62.00 49.00
Standard Safety Lock Master Safety Lock Standard Access Lock Master Access Lock
Note: Safety lock must be directly under head/cap or under Note: Access keys must be directly under safety locks (or under
internal release element (if one is fitted) head or internal release if no safety locks)
T K S T K M
Order Code Order Code
TKS TKM
12.00 14.00
ACCESSORIES
Standard Key Master Key
S M
Order Code Order Code
SM SS
No. of Safety Circuits 2 No. of Safety Circuits 2
22.00 No. of Control I/O 1
17.00
No. of Control I/O 0
S MD L S M E S M F S S E
(no monitoring contact on head)
U L U L U L U L
Power to Power to Power to Power to Power to Power to Power to Power to
Unlock Lock Unlock Lock Unlock Lock Unlock Lock
Order Code Order Code Order Code Order Code Order Code Order Code Order Code Order Code
SMDU SMDL SMEU SMEL SMFU SMFL SSEU SSEL
85.00 85.00 68.00 68.00 85.00 85.00 68.00 68.00
Order Code Order Code Order Code Order Code Order Code Order Code Order Code Order Code
EC EW ED EV ET EP EM EI
38.00 38.00 48.00 48.00 38.00 38.00 48.00 48.00
Reset Type Twist Pull Twist Twist Twist Pull Twist Twist
Extra Features Additional Illuminated Additional Illuminated
N/O contact N/O contact
No. of Control I/O 0 0 1 1 0 0 1 1
No. of Safety Circuits 0 Wired in series with TSS or TSM unit 2 Independently wired
S R
Max 10 characters on 2 lines
2 positon selector switches: 2 lines of
Max 10 characters at each switch position 10 characters
3 positon selector switches:
Order Code Max 10 characters at each switch position
SR
No. of Safety Circuits 2
P 1 Red G 1 Red
P 2 G 3
P 1
Yellow Green
P 3 Green G 5 Yellow
P 6 G 6
P 3
Blue Blue
P 7 White G 7 White Latching Momentary
P B Black G B Black 2 A
P R Red G R Red
P G Green G G Green
P W White G W White
P Y Yellow G Y Yellow
P Z Blue G Z Blue Latching Momentary Latching Momentary
W 3
Order Code Order Code
W1 W2 W3
Order Code
63.00 105.00
BF
4.00 W1 W2 W3
No. of terminals 12 12 24
Foot for terminating mechanical No. of control I/O 6 10 14
configurations (no wiring)
No. of safety circuits 2 2 4