A B C D E F G H

100x60x2.5mm RHS column


3cm thick Cement Screed
8cm High screed with 20% Slop 8cm thick RC Slab
supporting Agrostone wall
0.25micro thick Polythene plastic sheet
40cm Thick Back fill
welded Diagonaly on RHS column Well compacted soil
1 1
10cm thick Agrostone wall 60x100x2.5mm RHS Column
Ground Floor
Level Three coat antirust painted
60x100x2.5mm RHS Column
10cm thick Agrostone wall Three coat antirust painted

40x60cm Stone Masonry Foundation


Welding Connection

40x60x2.5mm RHS Column


Three coat antirust painted
NGL

2 2

Wall to Column Connection -Linear Wall to Column Connection -Corner


Scale 1:5 Scale 1:5
50mm thick Lean concrete

3
3

External Agrostone wall 3cm thick Cement Screed


8cm thick RC Slab
0.25micro thick Polythene plastic sheet
3cm thick Cement Screed 8cm High screed with 20% Slop 40cm Thick Back fill
100*60*2.5mm 8cm thick RC Slab supporting Agrostone wall Well compacted soil
RHS column 0.25micro thick Polythene plastic sheet 1cm thick wooden Plank
40cm Thick selected and
Compacted material to fill
Well compacted soil
Ground Floor
Level 4
40cm Wide & 60cm Deep
4 Stone Masonery Foundation
welded on RHS column

These drawings are not valid without the seals of the Client and the Architect/Consultant

No DATE INITIAL REVISION

Architect / Consultant:

BET

Project Name: Cost Efficient Typologies for Sugar


Development Projects
5
Building Type:
5 DT=Details
Client: Ministry of Works and Urban Development
Location:

Architects Design Team:


Daniel Alemayeh ARCHITECT, PPAR-249 AEA. UIA
Girmachew Tariku ARCHITECT, GAR-324
Yalew Seid ARCHITECT, GAR-361
Amaha Tigabu ARCHITECT, GAR-664
Fiseha Agonafir ARCHITECT, GAR-969
50mm thick Lean concrete Drafts Person Team Date of Issue:
Mahlet M. GJADT-070
May,2011
Serkalem N. GEA-157
Drawing Title: Scale: Index

Wall to Slab connection Detail

Drawing Stage:
1:5
Drawing No:
A

Scale1:5 Final DT-02/07