Professional Documents
Culture Documents
v.2.0
fpmccann.co.uk
Alnwick
Magherafelt
Weston Underwood
Ellistown
Lisnaskea
Byley Grantham
Drakelow
Telford
Lydney
Cadeby Littleport
FP McCann is the UKs market leader in the manufacture, supply and delivery of precast concrete
solutions. Our comprehensive precast concrete business extends to include:
Drainage and Water Management Solutions Tunnel and Shaft Solutions Rail Solutions
Power and Infrastructure Solutions Walling Solutions Fencing Solutions Flooring Solutions
Architectural and Structural Solutions Agricultural Solutions Specialist Precast Solutions
By applying the DFMA principles, FP McCanns design engineers are able to evaluate individual
precast concrete products part by part, in addition to documenting the assembly process step by
step. This allows them to generate the cost, part count and assembly time to provide a benchmark
to measure its success and identify the parts and process improvement opportunities. In turn, this
has allowed FP McCann to design and manufacture more cost-effective and efficient high-quality
precast concrete products with less wastage and greater on-site recycling. As a result, increased
productivity, combined with a reduction in production time and costs, allows FP McCann to be more
competitive within the marketplace.
Drainage With one of the largest drainage and
and Water
water management product ranges in
the UK and Ireland, FP McCann has
Management
become the first choice for all of our
customers.
1 Sustainability
Concrete pipes outperform other types of pipeline solutions in a number
of the environmental impact categories such as human toxicity levels
and chemical / hazardous waste generated. The CO2 emissions from
concrete and cement production are relatively small compared to other
building materials. Some 95 to 99% of ingredients used in the production
of concrete pipes are sourced locally, so a considerable positive impact
on the carbon footprint and fuel consumption associated with transporting
these materials can be achieved.
2 Strength
Concrete is much more durable than any other kind of pipe.
Hence, it can carry more load at any given time and gains
strength over time. It cannot be weakened by heat, moisture,
mould or pests, nor will it rust. Underground concrete pipes
have the ability to resist chemical attacks and massive
impacts such as jetting, so blockages will be cleared easily.
3 Quality
FP McCanns concrete pipes are manufactured in accordance
with BS EN 1916 and BS 5911 and certified by Quality
Assessment under the Kitemark Scheme and ISO 9001.
7 Chemical Resistance
Concrete pipes and manholes are resistant to
sulphate and chemical attack. Concrete pipeline
products with higher design chemical classes of
DC3 and DC4 are capable of withstanding attack
from the vast majority of aggressive ground
environments in the UK.
8 operational
Thermal mass and
energy
efficiency
Heavyweight materials such as concrete provide a
high level of thermal mass, a useful property which
helps regulate the temperature within structures. It
also has good acoustic properties, which avoids the
need for acoustic insulation for pipes.
Spigot and All of our spigot and socket pipes are manufactured
and CE marked in accordance with European Standard
Socket Pipes
BS EN 1916, the specification for unreinforced and
reinforced concrete pipes (including jacking pipes) and
fittings with flexible joints. They are also designed to
meet BS 5911 for concrete pipes and ancillary products.
C A B
Standard Pipes
Nominal Size DN 300 375 450 525 600 675 750 825 900 1050 1200 1350* 1500* 1800* 2100* 2400*
Internal Diameter A 300 375 450 525 600 675 750 805 900 1050 1200 1350 1500 1800 2100 2380
Barrel Diameter B 416 505 590 685 790 901 996 975 1080 1266 1460 1620 1800 2130 2460 2750
Socket Diameter C 497 575 665 760 852 960 1060 1130 1235 1420 1590 1800 2010 2380 2650 2750
Effective Length mm 2500 2500 2500 2500 2500 2500 2500 2500 2500 2500 2500 2500 2500 2500 2500 2500
Approx. Weight Kg. 450 590 730 975 1245 1820 2160 1690 2060 2760 3630 4290 5330 7300 9160 10070
Reinforced N N N N N N N Y Y Y Y Y Y Y Y Y
Approx. Pipes per load 62 50 40 30 22 15 13 17 13 10 8 6 5 4 3 2
Chamber Ring to suit 1200 1350 1500 1800 2400 2700 3000 3600
MOL Availability Y Y Y Y Y N N N N N N N N N N N
Crushing Strengths Kn/M 36 45 54 63 72 81 90 99 108 126 144 162 180 216 252 288
Nominal Joint Gap mm 4 4 4 4 4 4 4 4 4 5 5 5 7 7 7
Maximum Joint Gap mm 34 34 34 34 34 34 34 34 34 34 36 36 36 41 41
Maximum Deflection Degrees 2 2 2 2 2 2 1 1 1 1 1 0.5 0.5 0.5 0.5 -
* Easi-Lift Anchors Available
Pipe Lubricant
Pipes should only be joined using an FP McCann lubricant
Nominal size DN 300 375 450 525 600 675 750 825 900 1050 1200 1350 1500 1800 2100
No. of joints per Kg. 27 22 18 15 13 12 10 9 9 8 7 6 5 4 4
Sold in 2.5kg Tubs
Rocker Pipes
Nominal Size DN 300 375 450 525 600 675 750 825 900 1050 1200 *1350
*1500 *1800 2100
Effective Length mm 600 600 600 600 600 1000 1000 1250 1250 1250 1250 1250 1250 1250 1250
Approx. Weight Kg. 145 180 220 300 365 800 950 1020 1020 1200 1605 2020 2755 4440 4620
Nominal Size DN 300 375 450 525 600 675 750 825 900 1050 1200 1350 1500 1800 2100
Effective Length mm 600 600 600 600 600 1250 1250 1250 1250 1250 1250 1250 1250 1250 1250
Approx. Weight Kg. 100 135 155 205 270 870 980 750 910 1170 1585 1850 2230 3005 3800
Nominal Size DN 300 375 450 525 600 675 750 900 1050 1200 1350 1500 1800
Internal Diameter mm 300 375 450 525 600 675 750 900 1050 1200 1350 1500 1800
Approximate Weight KG. 140 175 220 290 360 775 925 1140 1515 1955 2425 2965 4105
All junctions are to be fitted on their side. Junctions are not designed for vertical
surface compaction and need to be surrounded in concrete.
Nominal Size DN 300 375 450 525 600 675 750 825 900 1050 1200 1350 1500 1800
Branch Size E 150 150 150 150 150 150 150 150 150 150 150 150 150 150
Effective Length mm 600 600 600 600 600 1000 1000 1250 1250 1250 1250 2500 2500 2500
Approx. Weight Kg. 132 169 211 277 350 750 905 800 1140 1513 2427 4416 5120 7360
160mm
Rigidrain
Naylor Ultra Polypipe
Coupling Bend
Clay Bend Rib Bend
SA10
Adaptor
Ultra Rib Pipe
Hepworth
Half U/R Connector Supersleeve
system
purpose-designed anchor system. Special lifting anchors are cast
into pipes at manufacture. A universal head link (available from FP
McCann) can then be hooked onto the exposed anchor heads to
lift the pipe.
Use the equal lengths (A & B) for lifting the pipe. Join the longer
chain (C) onto the pipe already laid and place the shorter length
(B) onto the hook. The pipe can then be jointed without moving
the jib of the crane. www.fpmccann.co.uk/anchor-system
WARNING
When Lifting 45
Inclined pull only
Engaging and disengaging the eye The chain set
A.
B.
C.
A.
B. A. B.
C.
Nominal size DN 300 375 450 525 600 675 750 825 900 1050 1200 1350 1500 1800 2100 2400*
Anchor Availability X X X X X X X X X X X Y Y Y Y Y
Anchor system available from 1350mm diameter upwards (Available in DN1200 in NI only) / * Lift only not jointing
Notes:
1. All dimensions are in mm. 5. Right hand or left hand junctions (viewed socket to spigot)
2. Weights in kg are based on a concrete density of 2500kg/m. should be specified when ordering reduced junctions in pipe
3. Where relevant, pipes are manufactured in accordance with diameters DN1350 and above.
BS EN 1916. 6. Lifting chains are not suitable for joining purposes in pipes of
4. Normal practice is to determine left or right branch laterals to the diameter DN2400. Joint in the traditional method.
main line by looking up the flow i.e. from the socket end. 7. Do not install vertical junctions.
1. 2.
Prior to assembly, inspect the pipes and ensure they are in good condition. Prior to assembly, clean the socket and spigot. Water and mud does not
The white protective strip in the socket helps to keep the sealing area free seriously affect the joint, but should be avoided. It is recommended that only
from dirt, mud and gravel etc. a FP McCann lubricant is used. Apply lubricant to the spigot end. Take
care that lubricant is evenly applied all around the spigot. It is important to
lubricate the radius area, as shown by the arrow in the picture. Lubrication is
easier with the pipe suspended. Dry jointing can result in severe damage to
the seal and pipe.
3. 4.
The protective strip is removed prior to jointing. Grip the tab of blue tape Centre the pipes and joint together. The socket design and wedge shaped
and pull towards the pipe centre, not towards the inside or outside. Small seal provide a funnel action and help centre the pipes. As the integrated
parts of the strip can remain in the pipe without affecting the joint seal is fixed in position, it is not dislodged during assembly. Critical guiding
performance. of the spigot and monitoring the seal position is no longer necessary. It is
advised that pipe joints are inspected directly after installation to ensure
complete assembly, and that air tests are carried out at regular intervals
using inflatable stoppers.
Note:
All junctions are to be fitted on their side. Junctions
are not designed for vertical surface compaction.
Angle 22.5 3 3 3
Angle 45 3 3 3
Note:
All junctions are to be fitted on their side. Junctions
are not designed for vertical surface compaction.
Lifting Chains
A
Heavy Duty Chain Set X X 3*
B C
*Only suitable for Lifting not Jointing
Handling/Lifting Instructions
Lift joint
DN1800 to DN2400 pipes are designed and manufactured to
incorporate FP McCanns jointing and lifting systems. To joint the pipe using the chain system, attach the long leg A and
the short leg B to the already laid pipe C. Take up the slack in the
Lift System chains with the lifting pulley over the anchor of the laid pipe, and
increase the upward force to joint the pipes. When jointed, ensure
that there is no excessive slew or misalignment, this can easily be
checked by reference to the joint gap.
A C B
WARNING
When Lifting 45
Inclined pull only
It provides tabular data for the drainage layout and specifies the
relevant FP McCann Easi-Bases automatically.
The FPM Tools toolbar is used to work through the drainage plan in
sequence, specifying each manhole in turn. Manhole references,
invert levels, cover levels, pipe types and pipe lengths are all
recorded. When complete, a table is generated within the actual
plan. This table can then be exported as a .csv file and opened in
MS Excel or other similar supporting program.
The screen shot above shows the drainage table generated within
AutoCAD and, to the right, the exported Excel table ready for the
quantity surveyor / buyer /estimator to send out for pricing.
www.microdrainage.co.uk
B C
A
Product Information
FP McCanns manhole chamber rings are manufacturered with tongue and groove joints and comply with
BS EN 1917 / BS 5911-3
Manhole chambers ex-Ellistown from DN2100 - DN3000 have 4 lifting points. Manholes less than
DN2100 have 3 lifting points
WARNING
Manhole chambers ex-Magherafelt from DN900 -DN2700 have 3 lifting points. DN3000 have 4 lifting points When Lifting 45
Inclined pull only
DN3600 and DN4000 are outside of the scope of the British Standard (Non-Kitemark), but comply with all
relevant provisions of the European Standard. DN4000 is supplied in two halves
* DN3600/4000 - see page 31 Manhole Chambers / DN3600/4000 Manhole Soakaways made to order
Sealing Strip
Nominal Size Sealant Size No. of rolls p/joint Rolls Required
(DN) (metres) (metres) Quantity
900 20x20x4m 0.88 1
1050 20x20x4m 1.00 1
1200 20x40x4m 1.13 2
1350 20x40x4m 1.25 2
1500 20x40x4m 1.38 2
1800 20x40x4m 1.63 2
2100 20x40x4m 1.88 2
2400 20x40x4m 2.13 3
2700 20x40x4m 2.38 3
3000 12x120x6m 1.75 2
3600 12x120x6m 2.08 3
4000 12x120x6m 2.33 3
Please note this is a guideline based on sealant supplied by FP McCann only.
Handling & Installing Manholes under some specifications, a concrete surround is required where
1. Time and place of off-loading should be agreed before the units the depth from ground level to the base of the concrete chamber
arrive at site. The contractor should provide suitable equipment ring exceeds 4.5m. In this case, the surround should be of
for off-loading. For safety reasons, all chamber sections are 150mm thickness. Backfilling should take place as each precast
loaded and delivered chimney fashion. manhole section is placed. It must be brought up evenly and
2. Off-loading should take place at the nearest hard road to the compacted around the manhole to prevent displacement.
point of installation. When off-loaded, units should never be
stored on their side (on the roll) but always be laid in the as Testing
installed upright position. It is generally unnecessary to apply water tests to manholes. In
3. Carefully inspect units during off-loading to verify that products normal working conditions, manholes are not normally full of water.
are undamaged and comply with order placed. Note any Prevention of infiltration is of more relevance than exfiltration. If
discrepancies on the delivery docket and advise accordingly. infiltration does occur, it can be seen and remedied by sealing using
an appropriate method.
Construction
To ensure that the manhole structure is vertical, accurate levelling Note: When handling precast products on site, it is recommended
of the formation or the in-situ concrete foundation is essential. that the contractor has the correct lifting equipment in place and
Please note: the depths of each manhole can vary and are adheres to the relevant lifting guidelines and standards.
subject to tolerances; it is recommended that each unit installed Refer to www.concretepipes.co.uk/technicalguides/index.php
has its depth measured prior to installation, to ascertain if the
levelling requirements are satisfactorily met. Tongue and groove Recommended Lifting Equipment
joints should be installed with the groove facing upward. Manhole
36mm 42mm 3 leg 4 leg
sections fitted with double steps can be used at any depth. Nominal
Lifting Hole Lifting Pin Lifting Pin Lifting Lifting
However, it is recommended that the deepest section of manhole
Qty/dia 3.5 t SWL 3.5 t SWL Chain 3.1t Chain SWL
Size
(p/Unit) 6.7 t
units should be used whenever possible, in order to minimise the
number of joints and costs. Precast cover slabs can be laid 900 3x45mm dia
directly onto the shaft or chamber rings. To allow for any
differential settlement between manhole and pipeline, a flexible 1050 3x45mm dia
joint incorporating short length rocker pipes should be constructed
1200 3x45mm dia
as close as possible to the outside of the manhole or the concrete
surround, if used. Extra care must be taken to ensure that joints 1350 3x45mm dia
are properly made.
1500 3x45mm dia
Jointing
1800 3x45mm dia
Precast manhole components are provided with joints formed
within the wall section. These are sealed with cement and sand 2100 4x50mm dia
mortar or with proprietary FP McCann mastic sealants. Precast
concrete manhole units, well jointed, provide an adequate seal
2400 4x50mm dia
under normal conditions. 2700 4x50mm dia
The DN4000 manhole chamber sections can be used in a variety The DN4000 chamber ring is supplied with a standard tongue and
of applications such as: groove joint, connecting bolts and butyl rubber sealant for jointing
purposes. The units are designed for use with the FP McCann
Water treatment plants ladder system. Single units (half ring) are lifted using 3 no. threaded
Stormwater attenuation systems lifting loops connected into threaded lifting sockets that are cast
Storage tanks into the units, all of which must be used. Assembled units (full
Catchpits ring) are then lifted using 4 threaded lifting loops.
DN4000 Cover slab 2 piece unit (Detail for standard 600 & 675 openings)
Heavy duty cover to suit Effective thickness Overall thickness Overall diameter Approx. weight of Approx. weight of
chamber section DN half section combined sections
mm mm mm mm kg kg
4000 300 300 4500 6450 11700
Cover slabs are manufactured in two sections, supplied with standard openings. Standard cover slabs are designed to withstand 30
units of Type HB loading, applied in accordance with BS 5911. If required, cover slabs can be designed to withstand 45 units of Type
HB loading. For special opening cover slabs, an engineering drawing and steel specification may be required in order to achieve the
desired loading requirement.
Note: FP McCann will provide a technical installation sheet which must be adhered to when installing DN4000 manhole chambers.
This is available online or from our sales team.
DN4000without tilt the chain lengths will differ. Refer to diagram below
Single units (half ring) are lifted using 3 number threaded lifting l
TECHNICAL
the units, DATASHEET TDS not
all of which must be used. The chain angle should 01
lifting/handling
& installation
Alternatively a spreader beam may be used.
Identification
guide notChamber
Complete units (full ring) are lifted using 4 number threaded lifting
ndling of 4000 Diameterthe Ring
Date:
units. Refer to diagram 27/02/2013
below Rev:
for explanation of the location
be less than 60 degrees to the horizontal. Alternatively a sp
unforeseen stresses on the concrete and may cause the concrete
uct Information
1. Lifting
Single units (half ring) are lifted using 3 no. threaded lifting loops
connected into threaded lifting sockets that are cast into the
units, (all of which must be used). The chain angle should not
be less than 60 degrees to the horizontal. In order to lift without
ing) are lifted using
tilt, the chain lengths3 willnumber
differ. Refer to threaded
the diagram opposite lifting
for loops which locate into threaded lifting socke
explanation of minimum chain angle and lengths. Alternatively, a
ich must spreader
be used. beam may The be used.chain angle
Complete units (fullshould not be less than 60 degrees to the horizontal. In
ring) are lifted
ain lengths
usingwill differ.
4 threaded Refer
lifting loops attachedtoto threaded
diagram below for explanation of minimum chain angle a
lifting sockets
cast into the units. Refer to the diagram opposite for explanation
eader beamof the may
location be
of theused.
lifting sockets to be used. The chain angle
should not be less than 60 degrees to the horizontal. Alternatively,
ll ring) areaNote:
lifted using 4 number threaded lifting loops which locate into threaded lifting sock
spreader beam may be used.
Using 3 chains to lift a full ring will put unnecessary
diagram stress
below on thefor explanation
concrete and may cause the of concrete
the location
around the of the lifting sockets to be used. The chain a
join to crack.
0 degrees to the horizontal. Alternatively a spreader beam may be used Note: Using 3 ch
es on the Unitconcrete and may
weight and identification cause
of lifting points willthe concrete
be marked on around the join to crack)
each casting for information.
2. Handling & Installation Unit weight and identification of lifting points will be marked on ea
It is recommended that the two piece chamber ring is jointed
before lifting into place:
2. Handling & Installation
Place the two units on a level surface, ideally on 2 skids to reduce
resistance when jointing and also to maintain a clean joint
It is recommended that two piece chamber ring is jointed before li
Place both halves side by side ensuring both are at the correct
orientation i.e. with bolt holes in line with threaded sockets
Insert the M24x200 threaded pins with the 60mm threaded
side placed into the cast-in sockets Place the two units on a level surface, ideally on 2 no
maintain a clean joint.
Place a strip of bituminous sealant along the small recess of the
vertical joint on both halves of the ring
Once bolts and sealant are in position, the 2halvesPlace
of the unitboth halves side by side ensuring both are at th
must be pulled together using a ratchet system e.g. a chain
threaded sockets.
block fixed to the cast-in M24x80 sockets on opposite ends of
toInsert
the units. (Do not use the wall end bolting system the M24x200 threaded pins with the 60mm thre
pull the units
together as this may crack the concrete and damage the joint)
The completed ring can then be manoeuvred Place
into place, as a strip of bituminous sealant along the small re
detailed above Once bolts and sealant are in position, the 2 halves o
entification of lifting points will be marked e.g.on abeeach
chaincasting for information.
block fixed to the cast in M24x80 sockets
Half-rings can be lifted into final position and the chamber can
built up, a half unit at a time.
end bolting system to pull the units together as th
tallation
Please note it is the end-users responsibility to The
ensure completed
safe ring can then be manoeuvred into pla
access and lifting procedures are followed at all times.
that two piece chamber ring is jointed before lifting into place:
Half-rings can be lifted into final position and the chamber can be
fpmccann.co.uk/drainage 01530 240000 | 23
the two units on a level surface, ideally on 2 no skids to reduce resistance when jointing and
Manhole
construction
Manhole Cover
2x Adjusting units
Cover slab
Shaft Section
Reducing Slab
2x Chamber Sections
Base Chamber
Quality
Easi-Base is a Kitemark product, manufactured and tested to Sealant
BS EN 1917
DN1200 12mm x 120mm x 4.2m
WRc tested and approved
DN1500 12mm x 120mm x 5.2m
Easi-Base is accepted for use by all major UK water companies DN1800 12mm x 120mm x 6.0m
Merchant Contact:............................................................
Contractor:.......................................................................
Contact Name:.................................................................
Contact Tel:......................................................................
Job Details / Address:......................................................
.........................................................................................
Order your Easi-Base unit using the PREDL Clock diagram.
The outlet is P with inlets available in any combination from 1-9.
Any angles from 90-270 are available.
Angles outside the parameters 90-270 are available upon
request, however, are subject to disclaimer.
Use the table below to place your order. Please consider the
example at the bottom of the table when placing your order.
One form is required per manhole base.
Notes
1. One form required per manhole base.
2. It is essential the pipe type is given correctly to ensure the
correct pipe adaptor to base is used.
3. Please confirm Cover Slab opening size required.
-
-
-
-
Advantages
Watertight structure
1520 KG
Slabs and
A
B
B
accessories
C
C
Landing Slabs
A Multiple access/other
access sized cover
B slabs can be made to
order
Chamber Section (DN) Outside Diameter (A) Opening Diameter (B) Slab Thickness (C) Approx. Weight (Kg.) Note:
Cover Slab sizes 900-3000 are manufactured
1200 1440 900 200 514 in accordance with BS 5911-3. DN3600 and
1500 1730 900 200 826 4000 cover slabs are generally designed in
1800 2050 900 200 1292 accordance with BS EN 1992-1-1, (for 30 units
of Type HB loading, can also be designed to
2100 2375 900 200 2030 withstand 45 units of Type HB loading).
2400 2705 900 200 2600 * Weights for DN3600 and DN4000 are
estimated weights based on solid slabs.
2700 3025 900 200 3880
3000 3330 900 200 4500
Note: A 600 x 600 eccentric corbel slab is also available when using a ladder BS EN 1917 and BS 5911
FP McCann manufactures a full range of adjusting units and corbel slabs that have the following advantages:
Designed as seating for manhole cover Sits on top of the manhole cover slab
Eliminates laying engineering bricks on-site Eliminates brickwork vertical joint weakspots
Quicker to lay, ensuring reduced labour costs Quality product produced by vibration process
65mm thick similar to brickwork Comprehensive strength similar to Class B.Eng bricks
Lothian Slab
A Size (A) (mm) Slab Thickness (C) (mm) Openings (B) (mm) Approx. Weight (Kg.)
B
*1125x1125 75 600x600/ 675x675 /750x600 140
*1125x1125 150 600x600/ 675x675 /750x600 290
*Scotland & Northern Ireland Only
C
ED
Working with partners Severn Trent Water, engineer Grontmij and
E CT
contractor to the water sector, Morgan Sindall plc, FP McCann has T
designed an award-winning safety solution. Easi-Safe is a PRO
temporary or permanent fall arrest system that allows for safe U N
working around the manhole opening prior to the fitting of the
ironwork.
With most standard cover slabs, the access point for man entry is
open and it is left to the contractor to cover on-site. In many site
situations, these openings remain for a number of days while
phases of work are completed. Easi-Safe immediately addresses
this problem. The future production of all standard access cover
slabs will incorporate the optional protective grid, which will remain
in the slab even when the final D400 steel cover and frame are set
in place at surface level.
Inspection
in four common sizes: 600 x 450, 750 x 600, 1000 x 675 and
1200 x 750. Manufactured in accordance with BS EN 1917 /
BS5911, each section has a tongue and groove joint and can be
chambers
sealed with a sand and cement mortar or bitumen sealant in the
same fashion as a circular manhole and chamber ring.
* Effective thickness
FP McCann
** Approximate weights
Chamber
Sections
Standard Horseshoe
Approx. Capacity
Dimensions (mm)
Nominal Weight
An integral seal and rodding eye for universal sealing characteristics Use on top of 450mm diameter gully
The rodding eye closure has been recessed into the concrete Eliminates laying engineering bricks on-site
to help eliminate dislodgment
Sits flush to kerb for enhanced stability
Reduced thickness, giving reduced weight and a smaller
footprint for better vehicle utilisation 100mm thick single piece unit
Improved system that helps prevent any discharge of oil Eliminates brickwork vertical joint weakspots
The gully is fully universal suiting all plastic and clay drainage Greater stability than brickwork
products from 160mm to 186mm diameter
Quality product produced by vibration process
Does not lose shape
Compressive strength similar to Class B.Eng. bricks
Does not float (self weight inhibits flotation)
Note: Gullies and Gully cover slabs manufactured in accordance with BS 5911-6
Catchpit
The catchpit effectively provides a sealed sump manhole, a monolithic precast concrete unit fitted
with connector seals, which can be used to connect to the following types of pipe: uPVC, twinwall,
clay, ductile iron and concrete. The catchpit is designed to accommodate pipe sizes DN150 to
DN450. The catchpit is designed in line with highway specification.
4-way units with orientations at 90 degrees can be produced up to DN300 only; beyond DN300
4-way orientations are not available. DN450 inlets must be cored on-site.
Catchpit weight 1.38 tonnes.
Accommodates connection to all types of pipe used in road and manhole construction
Safety benefits gained in the construction of manholes as the pre-formed sump and connect
seals eliminate on-site construction, thus greatly reducing labour activity within the manhole
Quality is greatly increased as construction is within the factory environment and complies with
BS EN1917 and BS 5911
Yields environmental benefits such as lower carbon footprint, less concrete used on-site and less
excavated material removed from site
The innovative EPDM 40 flexible rubber seal at the connection points can accommodate pipe sizes
DN150 to DN300, including DN225. This negates the need to saw cut openings in the concrete wall
and the use of wet mortar trades to seal the pipe surround.
Catchpits are supplied with factory fitted pre-marked EPDM 40 rubber blanks. The unique rubber
blank/seal has preformed cutting grooves around the three DN entry sizes indicated. This allows
for accurate cutting out to pipe diameter requirement. There is no similar system available on the
market. Once pipes are fitted into the seal, up to 45 degrees of pipe deflection is permitted without
breaking the seal.
Can be used in straight through, 90
connection or straight through with a
Significant savings in time eliminates the need for follow-up finishing gangs. Reduced safety risks
cross drain.
because the operative time in excavation is minimal and no power tools are required to cut concrete.
Indirect cost benefits arise from saving up to 26 hours of labour time, related to the curing of wet trades
on a traditional build.
FP McCanns catchpit products are manufactured under BSI Kitemark approval to comply with
BS EN 1917 and BS 5911, and are therefore fully compliant to HAs MCHW specification.
FP McCann designs and manufactures a wide range of headwalls designed to connect pipe work
discharging into open water courses.
Back wall Front wall Width at back Width at front Headwall Standard Wall Floor Approx.
Headwall Max Pipe O.D.
height Thickness Weight (Kg)
Accomodates Pipe Sizes height wall (internal) wall (internal) Length (mm) Invert level Thickness
Range mm (mm)
up to (external) mm (external) mm mm mm (Variable) (mm)
Part A 8500
*HW XXL 2100 2450 3090 1600 2659 3507 2560 100 250 250 Part B 8500
Part A 4750
*HW XL 1500 1800 2415 900 2027 2857 2060 100 250 250 Part B 4750
HW Large 200 900 1080 1420 660 1250 1945 2152 100 200 150 4100
HW Large 100 900 1080 1420 660 1250 1945 2052 100 100 150 2700
HW Medium 150 450 590 1150 670 702 1562 1380 100 150 150 1600
HW Medium 100 450 590 1150 670 702 1562 1330 100 100 150 1200
HW Small 150 300 410 810 530 525 1305 1360 100 150 150 1200
HW Small 100 300 410 810 530 525 1305 1310 100 100 150 1100
Advantages
WARNING
Prefabricated off-site (minimising on-site labour, costs and time) When Lifting 45
Inclined pull only
Quick and efficient to install (overcoming installation time limitations due to tides etc.)
The FP McCann Easi-Flow chamber combines an integral base allowable discharge. The hydro-valve therefore operates
and side walls with provision for inlet and outlet connections. automatically with no moving parts and no external power source.
It can be used in a number of applications, including: A typical application of this valve is to control the flow from
stormwater attenuation tanks by preventing downstream flooding
As a silt-trap during periods of heavy rainfall.
As a valve chamber
As a flow rate controller (requires installation of a vortex valve The hydro-valves are custom-designed to achieve a specified
unit, sold separately) design flow rate at a given head height. They are manufactured
under an ISO 9001 quality assurance system and are available in
Sizes available sizes compatible with the FP McCann Easi-Flow chamber range.
Easi-Flow chambers are available between DN1200 - DN3000.
Bespoke larger units can be manufactured to client specification. Hydro-valve customised specification
No moving parts
Flow rate control Self-activating
FP McCann can supply a hydro-valve vortex flow control device. Self-cleansing
The hydro-valve is designed to limit stormwater outflow to a Manual by-pass
specific discharge rate. Sizes are available between 1 80 l/s, Easy installation
depending on head height. The unit is self-activating with no need 3-6 times greater orifice CSA
for an external power source and comes with a certified flow rate. Hydraulic data available
The hydro-valve is a device for controlling stormwater flow caused For more information on hydro-valves, contact a member of
by a hydraulic effect without requiring moving parts. At low flow the technical sales team.
rates, water entering through the inlet passes through the vortex
chamber to the outlet with no restriction. As flow rate increases, *FP McCann advise you not to complete the manhole
water enters through the inlet with enough energy to create a construction until the JFC flow control device has been positioned
vortex in the chamber, which results in a considerable pressure correctly inside.
drop between the inlet and the outlet, restricting the flow to the
FP McCann designs and manufactures a bespoke range of reinforced valve chambers capable of
housing any size and type of valve/pump. Valve chambers consist of a precast concrete sealed
sump manhole with factory-fitted saddles to house the pump, and are used in the management of
water, oils and chemicals.
Benefits
Immediate watertight structure
Reduced installation time/costs
Accommodates connection to all types of pipe, including concrete, metallic, HDPE and clay
Pump is raised off the ground and sits on a pre-formed concrete stool
Easy and clean access for operation and inspection
Assembled in minutes
Stainless Steel Pull-ups available to suit ex stock
Product Specifications
BS EN 13101 Plastic Encapsulated Steps
WIS 4-33-01: 1990 Polypropylene Encapsulated Steps
Applications
Concrete manholes and inspection chambers.
Renovation of existing structures.
Materials
The plastic encapsulated ladder is made from high impact virgin
polypropylene copolymer plastic with a bright yellow coating. If
the ladder is to be subject to prolonged exposure to daylight then
black or UV stabilised material should be specified. It is reinforced
with structural steel.
Performance
Pull out load: 7.5kN minimum when fitted in
accordance with manufacturers instructions
Deflection under load: 5mm maximum at 2.5kN
Permanent Set: 0 mm at 2.5kN
Impact: 20kg weight from 1 metre, no cracking
Chemical Resistance: At least pH2 to 12
Integrity of plastic: 2M ohm at 500 volts DC
Thickness of plastic: 3mm minimum
Minimum cross section: 25mm diameter
Advantages
Excellent corrosion resistance
Visibility
No sharp edges
Eliminates need to specify exact length or fit on-site
Steel reinforcement gives predictable deflection under load
without causing brittle failure
Specification Advantages
The handhold has a pole length of 1200mm and can be assembled Helps the user find the first step safely
to give three different distances from the pole to the wall. This is Creates visual aid to indicate location of manhole to other
designed to accommodate different cover positions. people in the area
Easy to fit
Easy to raise and lower
High strength for ultimate safety
Low cost
Can be fitted to any Caswick step
Two projections for round or flat walled manholes
50 min. Tail
Length
Face of Wall
25 min.
125 mm
25 min.
10 max.
20 min.
25 min.
290 mm
25 min.
stormwater
Available straight from stock
management
Structural
The inherent structural strength of concrete is well documented
system
and can be designed to meet the severest of loading criteria.
Easi-Storm systems can be tailored to suit low load situations,
for example, when the tank is to be situated below verges or
gardens.
Benefits
System can be designed specifically to suit the application
Quick construction using a standard joint
The production of water impermeable surfaces in construction is
No need for fabrication on-site or external specialist
inevitable. This includes roof areas on buildings, car parks, loading
contractors
bays and road pavements. The provision of these surfaces interrupts
Straightforward installation using known techniques, no
the natural drainage process, creating increased stormwater
need to retrain
run-off in respect of both volume and flow rate.
Can be installed under roads and car parks
Can cope with construction plant loading
In many cases, this increase in stormwater flow and volume is a
Flotation is not a concern no need for geotechnical
problem as the local sewer or watercourse does not have the
anchors when located below the water table
sufficient capacity to cope. This problem could be alleviated by an
Long term solution
increase in the size of the stormwater sewer or watercourse, thus
providing the capacity within the drainage system to cope with the
Design
increased surface water. This, however, may be expensive, cause
The design of the system can be tailored to suit most structural
major infrastructure disruption, and can often be completely
and hydraulic criteria.
unfeasible.
Note
Concrete haunching should be used to provide local stiffening to
the concrete pipes with manhole entries. Use a minimum 150mm
thickness surround to the pipe, extending to a height of 300mm
above the pipe, in order to support the shaft joint.
FP McCann has designed and developed a new range of stormwater run-off. Water and pollutants enter the system via the
hydrodynamic separators for the treatment of urban catchment inlet pipe and launder channel arrangement. Low energy vortex
stormwater run-off. The hydrodynamic separator provides a flow patterns allow the floatables to gather and solids to settle to
cost-effective solution for designers, engineers and contractors the bottom of the treatment chamber for subsequent removal.
involved in the provision of Sustainable urban Drainage Systems Re-suspension of the solids is minimised by the provision of a GRP
(SuDS). The unit has no moving parts, requires no power and is baffle plate, positioned above the solids storage sump. Floatable
constructed within standard precast reinforced concrete chamber debris is retained within the hydrodynamic separator, allowing
rings. All internal flow components are manufactured in GRP, easy access for suction cleansing. Stormwater surges in excess
ensuring long life performance. of the maximum flow rate, overflow the weir, bypass the treatment
zone and is directly discharged through the outlet pipe. This helps
Independent Testing to minimize the effects of scour within the treatment compartment
FP McCanns hydrodynamic separator (1200mm diameter model) and optimises the performance of the hydrodynamic separator.
has been independently tested by WRc at their research and
development centre and achieved excellent total solids and Benefits
hydrocarbon removal at design flow rates. WRc tested and easy to install and maintain
Effectively removes and treats wide flow range
Total solid removal rates ranging from 85% to 92% have been Complies with SuDS legislation
recorded. The system is also effective in the removal of Cost-effective downstream defense mechanism
hydrocarbons, litter and other stormwater debris.
Applications
The hydrodynamic separator has demonstrated high level removal Housing developments
rates when design flows were exceeded. A summary of the WRc Highway drainage projects
test results are available from FP McCann, on request. Commercial/Industrial sites
Leisure facilities
Operation Existing surface water sewer discharges
The hydrodynamic separator is specifically designed to remove Pre-treatment for pond and wetland areas
suspended solids, hydrocarbons and floatable debris from the Sustainable Urban Drainage Schemes (SuDS)
Selection Chart
Part Number PRE EHS/1050 PRE EHS/1200 PRE EHS/1500 PRE EHS/1800 PRE EHS/2100
Chamber Diameter (mm) 1050 1200 1500 1800 2100
Treatment Flow Rate (l/sec) 15 25 35 50 75
Maximum Flow Rate (l/sec) 25 35 50 100 150
Inlet Pipe Diameter (mm) 225 300 375 450 525
Outlet Pipe Diameter (mm) 225 300 375 450 525
Sediment Storage Sump (m3) 0.75 0.85 2.50 3.00 3.2
Designed and manufactured in accordance with all current design Ease of installation
specifications and relevant standards, FP McCanns box culverts FP McCanns box culverts can be easily positioned in shallow or
are available in span sizes from 1000mm to 5400mm and internal deep fill installations.
heights from 500mm to 3600mm, dependent on the final mould
configuration adopted. A bespoke CAD design service is also Flexible sizes and internal features
available where non-standard unit sizes can be accommodated, Our box culverts can be manufactured in a range of sizes and
along with any other internal features requested by the client. accommodate features such as dry weather flow channels,
mammal ledges and dual cell configuration units, plus tapered
Using a modern production facility at Telford, Shropshire, and skewed units, if required.
FP McCanns experienced engineers and detailing team have the
flexibility to quickly respond to meet any design criteria and deliver Additional Features
nationally to just-in-time requirements. End walls, access points, vent holes, inlets, outlets, rungs, angles
and splayed ends can all be added to any culvert, as per
Supplied in either single or multiple runs, the use of precast requirement. Starter bars and sockets can be added to facilitate
concrete box sections in civil engineering projects is wide-ranging, any additional casting on-site, which may be required as part of
from their use for directing watercourses to the provision of the finished work.
attenuation tanks and underpasses. FP McCann is a member of
the Box Culvert Association (BCA) and their products comply with Box Culvert Applications
all relevant standards, as set out in accordance with ISO 9001 Attenuation and storage tanks
and ISO 14001. Water course diversion
Open channels
Structural strength and long life performance Road crossings
Our durable box culvert system meets the design life requirements Pedestrian and vehicle subways
for buried structures. Minimum maintenance is required. Shafts
Service tunnels and ducts
Conveyor protection
Access opening
Channels Specials
Half round (or equivalent) channels can be cast into the floor of Bespoke units accommodating a variety of features can be
the units at any position, with a choice of equivalent half round manufactured to the customers design requirements.
diameters.
Benching
Combined with either a channel or cast as a vee, benching
improves self-cleansing flow rates.
Internal Dimensions
(Based on flat invert culvert units)
Key: Flow area m2 / Discharge rate m3/sec
1000 1200 1500 1800 2100 2400 2700 3000 3300 3600 3900 4200 4500 4800 5100 5400
1.37 1.73 2.09 2.45 2.81 3.17 3.53 3.89 4.25 4.61 4.97 5.33 5.69 6.05 6.41
1200 -
1.76 2.37 3.00 3.64 4.29 4.95 5.61 6.28 6.95 7.62 8.29 8.97 9.64 10.32 11.00
2.18 2.63 3.08 3.53 3.98 4.43 4.88 5.33 5.78 6.23 6.68 7.13 7.58 8.03
1500 - -
3.21 4.09 4.98 5.89 6.81 7.74 8.68 9.62 10.57 11.52 12.48 13.44 14.40 15.37
3.17 3.71 4.25 4.79 5.33 5.87 6.41 6.95 7.49 8.03 8.57 9.11 9.65
1800 - - -
5.21 6.38 7.57 8.78 10.00 11.24 12.48 13.74 15.00 16.27 17.54 18.82 20.10
4.34 4.97 5.60 6.23 6.86 7.49 8.12 8.75 9.38 10.01 10.64 11.27
2100 - - - -
7.83 9.31 10.83 12.36 13.92 15.49 17.07 18.67 20.27 21.89 23.50 25.13
5.69 6.41 7.13 7.85 8.57 9.29 10.01 10.73 11.45 12.17 12.89
2400 - - - - -
11.11 12.94 14.81 16.70 18.62 20.55 22.50 24.46 26.44 28.42 30.41
7.22 8.03 8.84 9.65 10.46 11.27 12.08 12.89 13.70 14.51
2700 - - - - - -
15.11 17.32 19.57 21.84 24.14 26.46 28.80 31.16 33.53 35.91
8.93 9.83 10.73 11.63 12.53 13.43 14.33 15.23 16.13
3000 - - - - - - -
19.89 22.50 25.15 27.83 30.54 33.27 36.03 38.80 41.59
10.82 11.81 12.80 13.79 14.78 15.77 16.76 17.75
3300 - - - - - - - -
25.49 28.52 31.60 34.71 37.86 41.03 44.22 47.43
12.89 13.97 15.05 16.13 17.21 18.29 19.37
3600 - - - - - - - - -
31.96 35.44 38.97 42.53 46.13 49.76 53.42
Please note: These figures are a guide only and will be dependent on the mould configuration used in manufacture. Discharge rates are
calculated using Colebrooke-White equation for a fully wetted perimeter under uniform flow conditions and assuming a flat invert culvert
unit. The assumed laying gradient (s) is 1:1000 with a roughness co-efficient (k) of 0.3. Where different values maybe required, please
contact the office number below to discuss your specific requirements.
Design Criteria
Design loading criteria is generally specified by the scheme
engineer and ideally should include, as a minimum, the information
below:
Internal span
Internal height
Metres required
Number of runs
Minimum depth of fill over the culvert unit
Maximum depth of fill over the culvert unit
Culvert usage
Surface loading conditions : green field, highway etc
Invert type
Fit a Pipe Lifter to your excavator and you can The Manhole Lifter is a companion device that makes lifting
manhole rings a safe and easy, one-man operation. It eliminates
lay concrete pipes in around half the time with
the risk of vehicle falls during off-loading. There are two versions
less cost and less hassle but with greater available for precast concrete manhole rings from DN900 to DN1800
safety. and from DN2100 to DN3000. Its capable of lifting rings from
250 mm to 1000 mm deep.
Safer. No operative needed on vehicle during off-loading or in
trench during pipe laying. Find out more visit
Easier. Simple to use. No special equipment & minimal training www.concretepipes.co.uk/page/pipe-laying-lifting
required.
Faster. Around 50% saving on installation time. To buy or rent the Pipe Lifter, contact CPSAs supply partners
Cheaper. Fewer operatives plus greater productivity. MGF: 01942 402700 / www.mgf.ltd.uk
Mabey Hire: 0845 7413040 / www.mabeyhire.co.uk
The Concrete Pipe Lifter makes light work of the installation of AgriMac: 028 7778 1522 / www.agrimachinery.co.uk
waste water pipelines. Within seconds, it can be attached to your
excavator using a quick-hitch coupling. There are no hydraulic
links or additional energy requirements.
your lifters
and installation in an efficient manner. Each system is suited
to each type of product. The information below will allow you
to determine what lifting attachments are required. This list is
not exhaustive and may be subject to change. Please contact
FP McCanns technical department if you are unsure about
any aspect of lifting. Please be aware that it is the contractors
responsibility to ensure all lifts are safe and compliant with
legal requirements.
4No RD36 Lifting Loops Please be aware that the loops are not intended
4000 Standard Chamber Rings (2 part) screwed into the top face for prolonged use. Instructions for handling
of the ring are shown on the product itself.
1200 to 1800 Wide-Wall Chamber Rings 3No 5t Spherical Head Clutch Attach to the OUTSIDE of the ring.
10t Spherical Head Clutch Clutches and chains allow safe lift and easy
1350 to 2100 Standard Pipes and Fittings
and Chain Sling Set installation of units.
20t Spherical Head Clutch 12-20 tonne shackle 2 leg lifting chain only
2400 Standard Pipes and Fittings
and Chain Sling Set
MECHANICAL GRABS - The Quicker, Easier and Safer Option for handling Rings and Pipes.
These attachments connect to site plant and allow off-loading and installation without any need for access to the trailer bed. Mechanical
grabs are available for pipe diameters DN300 to 1200 and for ring diameters of DN900 to 3000. For further information, contact your
sales representative.
Easi-bases, Head Walls and flow control chambers come supplied with the correct lifters ready for use. Catchpits should be handled
with a mechanical grab. All lifters supplied by FP McCann come with appropriate certification and are ready for use. Lifters should be
incorporated into the contractors lifting equipment inspection regime under LOLER regulations or disposed of after use.
INCORRECT CORRECT
Eyes passed through from the outside with hooks connected to Eyes passed through from the inside with the plate and nut
the outer face of the ring. Pins can come loose if nuts not ap- applied to the thread on the outside, or self-locking mechanism
plied or the self-locking mechanism has not engaged and the engaged. Hooks are connected to the inside of the ring to allow
concrete can be crushed by the chains. for a safe lift with straight chains.
For safe lifting in situations when access to the product is restricted (i.e. when stacked high or on a trailer bed, a mechanical
grab should be employed). Wide wall chamber rings are lifted via a different method (see page opposite).
Bespoke chamber components such as Easi-Bases and Flow Control Chambers will feature a separate handling method.
Reference should be made to appropriate drawings or handling information.
Pipe openings
to suit customer
requirements
Contractor:
Clugston Construction Ltd.
Client:
Leeds County Council
Products Supplied:
Bespoke Precast Modular
Storage Tank
Rail Solutions
Cadeby 01455 290780
Walling Solutions
Lydney 01594 847500
Fencing Solutions
Cadeby 01455 290780
Agricultural Solutions
Lydney 01594 847500 Magherafelt 028 7954 9026
Flooring Solutions
Weston Underwood 01335 361269