You are on page 1of 2

S afety devices S pecifications

The Series Z escalator is equipped with


various safety devices that provide for
safety and reliability. For EN115 Code For EN115 Code
Max rise (mm): 7000 (30), 6000 (35)

Standard Optional StandardOptionalN/ANot applicable

Step Motion Safety Device (CRS) Emergency Stop Button (E-STOP) Division Specification
ZS ZL ZP
A safety device to stop the escalator when a Step has been A button to immediately stop the escalator in emergency Indoor
dislocated on its riser side due to an object caught between situations. Environment Semi-outdoor *1
the Steps, or between the Skirt Guard and the Step, or if an
Outdoor *1 *1 N/A
abnormality has been observed in the Step motion. * Door Open Switch (DOS) AC1
A safety switch that stops the escalator when the manhole Inverter (VVVF) *2
Control
cover is opened. Automatic Operation with Posts (Stationary in stand-by, AC1)
system
* - EN115-1: 2008 + A1: 2010 Standard
Automatic Operation with Posts (Slow operation in stand-by, Inverter)
- EN115-1/A2: 2004 Not applicable Post-Free Automatic Operation (Slow operation in stand-by, Inverter)
Stop-Buzzer Key Switch
Overload Detection Device Anti-Slip Floor Plate
Step with Anti-Slip Grooves
A safety device that stops the escalator if overload has
Demarcation Line
been detected by abnormal current or temperature of the
drive motor. Tiered Demarcation Line
Safety Step Demarcation Lighting
Drive Chain Safety Device (DCS) features Comb Light
Three Horizontal Steps / *3
A safety device that stops the escalator if the Drive Chain
Warning System on Moving Handrail Inlet (Inlet Sensor) *4
breaks or stretches beyond an allowable limit.
Warning System on Outer Deck (Outer Deck Sensor) *4 N/A
Directional Indicator on Handrail Inlet Cap (Handrail Inlet Cap LED Indicator) *4 *5
Speed Governor (GOV)
Balustrade Transparent tempered glass panel N/A
A safety device that stops the escalator if the speed See page 12 for Under-Handrail Lighting N/A N/A
significantly decreases or increases to 120% of the rated sections. Stainless steel hairline panel N/A
speed.
Skirt Guard Fluoropolymer Coating
* Auxiliary brake Electromagnetic Brake Skirt Guard Lighting *6 N/A *6
Deck Board Stainless steel hairline
A safety device that stops the escalator if the speed A safety device that stops the escalator in the case of Aluminum alloy Step Tread
Step
exceeds the rated speed, or before the Steps power failure, or if any safety device or the Emergency
Finish and Aluminum alloy Cleat Riser
traveling direction changes due to an abnormality Stop Button has been activated.
such as breakage of the Drive Chain. decorative Yellow Demarcation Line
components Floor Plate Decorative Panel (Embossed stainless steel)
* A standard device for public-use escalators or those
exceeding 6m in rise. Floor Name
Comb
Extension of Floor Plate
Connection of adjacent Floor Plates
Step Level Device (SRS) * Handrail Speed Safety Device (HSS) Moving Handrail Rubber No. 0001 (Black)
A safety device that stops the escalator if the horizontal A safety device that stops the escalator if the Moving
(See page 5 for colors.)
No. 0502 to 0508
level of a Step has dropped. Handrails fail to synchronize with the Steps due to Handrail Inlet Cap Resin
slippage, loosening or breakage of the Moving Handrails. MelEye
Others
Skirt Guard Safety Device (SSS) * - EN115-1: 2008 + A1: 2010 Standard
Automatic oiler
- EN115-1/A2: 2004 Optional *1: Please contact your local Mitsubishi Electric sales agent for semi-outdoor and outdoor use.
A safety device to stop the escalator if a shoe or other
item becomes trapped in the gap between the Step and *2: Please contact your local Mitsubishi Electric sales agent for VVVF control.
*3: A standard feature for rises exceeding 6000mm or rated speeds exceeding 0.5m/sec.
Skirt Guard.
*4: Not applicable to outdoor use.
*5: Installed only on the right-side Handrail Inlet Cap (when viewed from the boarding and landing areas).
Comb-Step Safety Switch (CSS) *6: Not applicable to semi-outdoor and outdoor use.

A safety device that stops the escalator if a foreign object Deck Board
becomes trapped in the gap between the Step and Comb. Moving Handrail

Handrail Guard Safety Device (HGS) Balustrade


1) Inlet Guard
A guard made of soft rubber, which fits over the
outside of the Moving Handrail where it enters the Skirt Guard Step
Balustrade to keep fingers, hands or foreign objects
away from the Moving Handrail opening.
2) Inlet Guard Switch
A safety device that stops escalator when physical
contact is made with the inlet.

Step Chain Safety Device (SCS)


Floor Plate
A safety device that stops the escalator if the Step Chain * Missing Step Device (SMS)
breaks or stretches beyond an allowable limit. A safety device that stops the escalator if it detects a Operating Panel
missing step(s) before it is visible to passengers.
* - EN115-1: 2008 + A1: 2010 Standard
- EN115-1/A2: 2004 Not applicable Escalators in the graphics are based on the Japan Code, with optional
Fluoropolymer Coating on Skirt Guard.

e4 L - 1 7 0 - 6 - C 7 9 4 0 0 -E e1
L ayout For EN115 Code

EN 30 EN 35
Manhole cover
(Unit: mm) Manhole cover Manhole cover (Unit: mm) Manhole cover

Floor opening
Floor opening
Comb Comb Comb Comb

W1+100
W1+100
NK-865 NJ-865 765 1035

RC, SRC structure Min. 270 RC, SRC structure Min. 270
12010

12010
Steel structure Min. 250 Steel structure Min. 250
Finished floor level Finished floor level
Lower floor opening Wiring inlet (R.H.) Max. LF Lower floor opening Wiring inlet (R.H.)
Max. LF Upper floor opening Max. UF Max.UF
Upper floor opening
LL=TG+250
+40
75 LL=TG+250
75 Distance between support beams MM 0
Anchor Anchor +40
+30 +30 75
50 0 Truss length TG 50 0 75 Distance between support beams MM 0
Support beam end Support beam end
+30 +30
Truss end Truss end 50 0 Truss length TG 50 0
TK HE/tan30 TJ
TK=2260 HE/tan35 TJ=2530 (S1000, S800)
Support beam section detail (by owner) Support beam section detail (by owner) TJ=3080 (S600)
LA Max. 11000 for S1000, S800 LB Max.11000 for S1000, S800
Max. 11700 for S600 Max.11700 for S600 Clearance LA Max. 11000 for S1000, S800 LB Max. 11000 for S1000, S800
W1 NJ Min.2000 W1
Safety fence Max. 11700 for S600 Max. 11700 for S600 Clearance
(by owner) Safety fence
W2 NJ Min.2000
W2 (by owner)

W3

950
W3

950
R2100 RB R2100

250
RB

250
F.L. F.L.
F.L. F.L.
Wedge guard W.P.
Wedge guard W.P.

1030
(by owner) NJ-385 (by owner) 1515

1030
79
440 440
20 440

0
440

79
Ceiling 215
Recommended Recommended

0
Ceiling
Min. 2320
Overhead

Clearance Recommended
Wiring inlet (R.H.) Recommended Clearance
Min. 2000 NK
HERise

91
Max. 7000

125 Min. 2000

Min. 2340
Overhead
NK 2390 (S1000,S800)

Max. 6000

5
HERise
91 Wiring inlet (R.H.)
5 Truss TJ-140 R1500 2940 (S600)
R1500
50

Outer sheathing Truss


panel (by owner) Outer sheathing
950

RC panel (by owner)


RA
30

950
RC
RA

35
F.L.
SA

F.L.

SA
Intermediate support beam is W.P. Intermediate support beam is
W.P.
required when TG exceeds required when TG exceeds
Floor opening
1030
1100

15000mm for Type S1000 Floor opening 15000mm for Type S1000

1030

1100
NK-385 Min. 2000 Height of intermediate
15500mm for Type S800 or 1245 Min. 1800 15500mm for Type S800 or
support beams,1801000. Height of intermediate
16000mm for Type S600 16000mm for Type S600
support beams,1801000.

For VVVF control, TJ may increase from that shown. Please contact For VVVF control, TJ may increase from that shown. Please contact
your local Mitsubishi Electric sales agent for details. your local Mitsubishi Electric sales agent for details.

Standard dimensions Reaction force on beam (N) Standard dimensions Reaction force on beam (N)
Type S600 S800 S1000 Without intermediate support beam With intermediate support beam Type S600 S800 S1000 Without intermediate support beam With intermediate support beam
W1 (Escalator Width) 1150 1350 1550 W1 (Escalator Width) 1150 1350 1550
4220(TK-X1)
W2 (Between Moving Handrails) 840 1040 1240
RA LL+ 4220(LL-TK+X1)+12000(TJ-X2) LA+4220-
W2 (Between Moving Handrails) 840 1040 1240
RA LL+ 4220(LL-TK+1111)+12000(TJ-1370) LA+4220- 4220(TK-1111)
LL LA LL LA
W3 (Between Skirt Panels) 610 810 1010 W3 (Between Skirt Panels) 610 810 1010
RB LL+ 4220(TK-X1)+12000(LL-TJ+X2) LB+12000- 12000(TJ-X2) RB LL+ 4220(TK-1111)+12000(LL-TJ+1370) LB+12000- 12000(TJ-1370)
Horizontal Steps LF UF NK NJ LL LB Horizontal Steps LF UF NK NJ LL LB
2 Steps 850 1100 1550 1835 2 Steps 1095 1365 1630 1900
RC LL+ 4220(TK-X1) +
12000(TJ-X2)
RC LL+ 4220(TK-1111) + 12000(TJ-1370)
3 Steps 1440 1725 1975 2260 LA LB LA LB

Reaction force factors Reaction force factors


2 Steps
(N/mm) (N/mm)
TJ
Environment Type TK X1 X2 Environment
Type TG HE 6000 Type TG
Indoor S1000 Indoor
Outdoor Outdoor
Semi-outdoor 2465 Semi-outdoor
S800 2180 1031 1305
TG 13500 5.25 TG 13500 5.25
S1000 13500TG 15000 5.32 5.25 S600 3015 S1000 13500TG 15000 5.32 5.25
15000TG 5.25 3 Steps 15000TG 5.25
TG 13850 4.56 TJ TG 13600 4.56
Type
S800 13850TG 15500 4.62 HE 6000 6000HE TK X1 X2 S800 13600TG 15250 4.62
15500TG 4.56 S1000 3440 15250TG 4.56
TG 14200 3.87 2890 TG 14200 3.87
S800 3440 2605 1456 1730
S600 14200TG 16000 3.93 3.87 S600 14200TG 16000 3.93 3.87
16000TG 3.87 S600 3440 16000TG 3.87

e2 e3