Hello all,

Can anyone tell me what is the step-by-step do achieve the following:

This relate to the Characteristics value table - AUSP

1. Configure and trigger the changes made in AUSP in the change document tables -
CDHDR/CDPOS
2. Configure and trigger the changes made in AUSP as a change pointer in tables - BDCP2

Please tell me the steps, including t-codes.

Good answers will be highly appreciated.

Thanks & regards.

Hi, check note 943559. It has steps to activate the change logs for classification data. Also check the
below wiki:
http://wiki.sdn.sap.com/wiki/display/PLM/Activate+change+documents

0 likes

For the AUSP characteristics here is what you need to do:

1. BD50 - activate IDOC CLFMAS (not BATMAS)

2. BD52 - add the OBJECT: CLASSIFY and Table: ABAUSP for the fields desired shown below and
add additional fields if needed.

CLASSIFY ABAUSP ATINN

CLASSIFY ABAUSP ATWRT

CLASSIFY ABAUSP ATFLV


3. BD64

4. To test make a change to one of the characteristic values and then run BD21 using CLFMAS. It
will generate the IDOC with the data you need.

How to Activate Change Documents in


Classification System
Skip to end of metadata

Created by Sandra Hauptmann, last modified by Akos Szelenyi on Nov 25, 2016
Go to start of metadata

The indicator 'Change Docs' can be set in transaction O1CL. Due to technical reasons, this indicator cannot be set until the
class type allows 'Multiple objs allowed'.

It is not possible to set the 'Multiple objs allowed' indicator directly in the transcation O1CL. The program RCCLUKA2 has to
be started. This report sets the 'Multiple objs allowed' indicator for a class type. The system does a key conversion for
tables KSSK and AUSP and creates a new table INOB. The conversion only affects the class type, which is entered. Internal
keys for the objects are saved to table INOB. For more information about RCCLUKA2, please read the documentation of the
program and Note 942691.

Now, the 'Change Docs' indicator can be set, as well. However, it only says that change documents are generally possible
for this class type. In addition, the objects for which the change documents should be written, have to be selected .

Note: If you have to activate the 'Multiple objs allowed' flag on several systems, please don't transport the field from
one system to another You have to activate the flag on every single system via the report RCCLUKA2