You are on page 1of 8

VENTILATED FAADE SYSTEM

VARIO
JAN /2010

FOR MOUNTING CERAMIC


TILES AGROB BUCHTAL
MAIN ADVANTAGES OF VARIO SYSTEM

Vario ventilated
faade system is
Easier and safer mounting of the adapters in tiles grooves by
means of a specially designed polymer (PA6 30GF) accessory
(developed by ETEM Building Systems), which basic use is to align
and position the aluminium hanger (designed by Agrob Buchtal).

designed for
invisible mounting
of ceramic tiles Easier fixing of the vertical gap between tiles by means of a main

Agrob Buchtal
supporting vertical profile with customized shape which prevents
tiles movement in horizontal direction.

Kera Twin K15/K18


by means of
adapters.
Possibility of painting the visible part of Improved protection against rainstorm.
the joint profile in colour to match the
colour of the faade material.

250 mm
250

300 mm
300

200 mm

200

Possibility for production of pro- Possibility for production of The both-side punched profile is the
files, suitable for mounting of tiles the main supporting profiles only solution for finishing to windows
in different heights on one profile. in custom lengths from that are too close to the construction
186 mm up to over 4000 mm. base (up to 50 mm) and for coating
of pillars.
Stress reduction in angle
areas, i.e. increased
stability of the fins.

Vario ventilated
Increase overall stability
and compensate for reduced
strength around holes.

faade system is Stress reduction


in angle areas.

designed for Gap formation (shaping)


and increase of profiles

invisible mounting
moment of inertia. Variety of wall brackets heights.

of ceramic tiles Circle and oval shaped

Agrob Buchtal
holes meeting the
requirements of statics
Benchmark helping of aluminium constructions.
the tiles mounting.

Kera Twin K15/K18


by means of Holes allowing for precise positioning of
the wall brackets on the construction base.

adapters.
Stress reduction in angle
areas of the hole.

Secure supporting metal part and spring Clamps for fast and secure fixing
effect part of composite material. and clearance compensation.

+ 60oC - 40oC
Four specially designed adapters
are stuck in the grooves on the
backside (invisible) of the ceramic
tiles. Those adapters (together
with the plate) are subsequently
placed in preliminary punched
holes on two adjacent vertical
supporting profiles.

Vario ventilated system is developed in 2007 as a


result of the cooperative work of leading installing
companies and ETEM Building Systems in coordina-
tion with Agrob Buchtal.

Vario system is based on Agrob Buchtal system


Kera Twin K15/K18 with invisible adapter fastening
for mounting ceramic tiles with 15 and 18 mm
thickness.
EIS
(ETEM INTEGRATED SOLUTION)

EIS (ETEM INTEGRATED SOLUTION) is a product of ETEM Building Systems Each architectural system independent on its application is designed with re-
that provides the client with a complete system and engineering solution of spect to strictly defined requirements. EIS provides the client with a complete
the project. EIS includes: solution in accordance with the following requirements and norms:

1. Static analysis: EIS SAFETY REQUIREMENTS FOR: EIS DURABILITY


Load analysis REQUIREMENTS FOR:
Selection of the optimal static scheme Stability
Selection of the required system profiles, wallbrackets, Wind resistance Unchanged characteristics under
accessories and fastening elements Impact resistance influence of impacts
2. Selection of the substructure elements: Corrosion resistance Unchanged characteristics under
Selection of profiles and accessories Fire resistance influence of heat, solar radiations,
Selection of optimal fixed supports, withstanding the Security against penetration rain water, freezing and melting
combined loading of the material weight and the wind load Safety against electromagnetic effects Unchanged characteristics under influence of fogs,
Selection of optimal flexible supports with respect industrial environment, wind and dust
to the dynamic loads of wind pressure and suction Unchanged characteristics under influence of water
3. Complete or modular project calculation; penetration
EIS COMFORT
4. Design of customized parts; Unchanged characteristics under corrosive influ-
5. Manufacturing of non-standard REQUIREMENTS FOR:
ence of the microclimate environment
profiles and accessories;
6. Manufacturing of profiles of non-standard lengths Air-tightness
Water tightness EIS OUTLOOK
and customized finishing processes;
7. Working out a principal mounting plan of the Thermal insulation REQUIREMENTS FOR:
specific project modules; Condense control between layers
8. Trainings, tutorial classes and issuing certificates Odour emission from materials Flatness
upon successful course completion; Emission of gas, dust and noxious radiations No surface defects
9. Support at installation start; Outer noise insulation Colour consistency and gloss
10. Inspection of ongoing project; Side and vertical insulation of inner noise Easy cleaning
Acoustical behaviour with respect to rain
and hailstorm EIS LOGISTICS
Acoustical behaviour with respect to wind, tem- REQUIREMENTS FOR:
perature differences and moisture.
EIS guarantees the client for highest safety degree of architectural system, Easy transportation of components
Convenient storage of components
designed as per BNS ENV 1999-1-1, Eurocode 9 and in accordance with the Eu- Simple assembly of components
ropean and national norms. Fast replacement of worn out elements
Main supporting profile adapter

Name Minimum Maximum Reaction Force Reaction Moment


Constraint Name
Equivalent Stress 7,903e-004 MPa 21,81 MPa
Magnitude Component (X,Y,Z) Magnitude Component (X,Y,Z)

Maximum Principal Stress - 4,38 MPa 27,26 MPa


34,3113 N 0,0000283839 N m
Fixed Constraint: 1 45,5764 N 29,9991 N 0,0872676 N m 0,00238313 N m
Minimum Principal Stress - 22,27 MPa 4,395 MPa 0,00233145 N -0,0872351 N m

Deformation 0 mm 0,1643 mm
150,849 N 0,00000183696 N m
Frictionless Constraint: 1 150,849 N 0,00761863 N 0,197133 N m -0,00345596 N m
Safety Factor 7,337 N/A -0,00930697 N -0,197103 N m

-83,526 N 0,0000280643 N m
Frictionless Constraint:2 83,526 N -0,0249112 N 0,163991 N m 0,00121082 N m
-0,00318689 N -0,163987 N m
STATIC ANALYSIS INSTALATION PLAN

Offer No.36
03 December 2009

Project name: Office building STFA, Qatar

Static analysis

AGROB BUCHTAL KeraTwin K18 with adapter fastening

tSystem: Vario

Input data:
Building height: 29 m
Storey height: 4.2 m
Faade material: KeraTwin K18, 300x1200

Loads:
Faade weight: 32 kg/m
Wind speed: 45 m/s
Dynamic pressure: 0.76 kN
Wind load: 1.02 kN
Wind suction: 0.76 kN
LEGEND
Fixed support:
07vario08275/160
Load of weight: 1.61 kN Main profile 07B300F
Wind suction: 0.27 kN
L55x55x2, one
Flexible support:
side punched
07vario08275/160
Wind suction: 0.92 kN
Fixed support
Profile 07B300F:
Length 4186 m
Distance between profiles: 0.6 m Flexible support
Distance between brackets: 0.84 m
Max. Stress: 27.59 N/mm2
Joint profile
Max. Deflection: 0.45 mm
Safety Factor: 5.8

Thermal expansion:
l = L/2*t*0.0023
l = 0.14 mm
Temp. difference (+12.8 to +41.5)
OFFICES
ETEM BUILDING SYSTEMS BULGARIA
T: +359 894 754 158, ventilated@madeinetem.com, www.madeinetem.com

ETEM BUILDING SYSTEMS GREECE


T: +30 210 489 8605, marketing@etem.vionet.gr, www.etem.gr

ETEM BUILDING SYSTEMS ROMANIA


T: +40 21 209 09 70, contact@etem.ro, www.etem.ro

ETEM BUILDING SYSTEMS SERBIA


T: +381 22 32 80 19, +381 22 32 80 20, office@etemscg.rs, www.etem.gr

ETEM BUILDING SYSTEMS UKRAINE

VENTILATED FAADE SYSTEM T: +38 (044) 499 07 87, info@etem.com.ua , www.etem.com.ua,


www.etalbond.com.ua, www.ventfacade.com.ua

This brochure only reflects the state of our products at the time of printing.
You can find updated information on our website:

MADEINETEM.COM
Technical or any other questions can be directed to us by e-mail at: pdimitrov@steelmetbg.vionet.gr
or use our telephone number: T: +359 894 754 158

INTERNATIONAL PARTNERS
UKTOP ARCHITECTURAL LTD
T: + 442086017172, + 447990865543, peter.hristov@uktop.eu, web:www.uktop.eu

CERAM OBJEKT s.r.o.


T: 00420 2717417414, brabec@ceramobjekt.cz, www.ceramobjekt.cz

ANTALIS POLAND SP. Z.O.O


T: +48 (0) 693 921 048, cezary.grzebski@antalis.pl, www.antalis.pl

INTERNA TRADING FZCO, UAE


T: +971 4 422 6727, jerry@internagroup.ae, www.internagroup.com

ILTEGRO SPOL. S R.O., CZECH REPUBLIC


T: 00420 605822338, iltegro@iltegro.cz

MKN DOO, MACEDONIA


T/F: 0038925110118, mkn_doo@yahoo.com, www.mkn-etem.com.mk

MM SYSTEM, SLOVAKIA
T: +421 2 455 25 694, mmsystem@nextra.sk

You might also like