SIEVE ANALYSIS
SIEVE SIZE (mm) WT. RETAINED (g.) % RETAINED % PASSING % PASSING SPEC
37.5 0.0 0.0 100.0 100
25.0 0.0 0.0 100.0 100 .-
20.0 0.0 0.0 100.0 100 100
14.0 10.0 0.5 99.5 100
12.5 9.0 0.4 99.1 99 90 - 100
10.0 690.0 32.6 66.5 66 40 - 70
5.00 1299.0 61.4 5.1 5 0 - 15
2.00 75.0 3.5 1.5 2 0-5
1.180 1.0 0.0 1.5 1
0.600 5.0 0.2 1.2 1
0.150 0.0 0.0 1.2 1
0.075 0.0 0.0 1.2 1 .-
-0.075 26.0 1.2
100
TOTAL 2115.0
GRADING
80 ( % Passing Sieves )
60
40
20
0
2 20
SIEVES ( mm )
CONTRACTOR CONSULTANT
PROJECT : FISH TOWN - HARPER ROAD - MONROVIA
CONSULTANT : COMPTRAN ENGINEERING AND PLANNING ASSOCIATES.
CONTRACTOR : CHINA RAILWAY
SIEVE ANALYSIS
SIEVE SIZE (mm) WT. RETAINED (g.) % RETAINED % PASSING % PASSING SPEC
37.5 0.0 0.0 100.0 100
25.0 0.0 0.0 100.0 100 .-
20.0 0.0 0.0 100.0 100 100
14.0 0.0 0.0 100.0 100
12.5 5.0 0.2 99.8 100 90 - 100
10.0 611.0 30.0 69.7 70 40 - 70
5.00 1331.0 65.4 4.4 4 0 - 15
2.00 68.0 3.3 1.0 1 0-5
1.180 1.0 0.0 1.0 1
0.600 1.0 0.0 0.9 1
100
0.150 0.0 0.0 0.9 1
0.075 0.0 0.0 0.9 1 .-
80
-0.075 19.0 0.9
GRADING ( % Passing )
TOTAL 2036.0
60
40
20
0
2 20
SIEVES ( mm )
DESIGN GRAD. LOWER SPEC UPPER SPEC
CONTRACTOR CONSULTANT
PROJECT : FISH TOWN - HARPER ROAD - MONROVIA
CONSULTANT : COMPTRAN ENGINEERING AND PLANNING ASSOCIATES.
CONTRACTOR : CHINA RAILWAY
SIEVE ANALYSIS
SIEVE SIZE (mm) WT. RETAINED (g.) % RETAINED % PASSING % PASSING SPEC
37.5 0.0 0.0 100.0 100
25.0 0.0 0.0 100.0 100 .-
20.0 0.0 0.0 100.0 100 100
14.0 5.0 0.2 99.8 100
12.5 7.0 0.3 99.4 99 90 - 100
10.0 650.5 31.3 68.1 68 40 - 70
5.00 1315.0 63.4 4.7 5 0 - 15
100
2.00 71.5 3.4 1.3 1 0-5
1.180 1.0 0.0 1.2 1
0.600
80 3.0 0.1 1.1 1
0.150 0.0 0.0 1.1 1
GRADING
0.075 ( mm ) 0.0 0.0 1.1 1 .-
60
-0.075 22.5 1.1
TOTAL 2075.5
40
20
0
2 20
SIEVES ( mm )
DESIGN GRAD. LOWER SPEC UPPER SPEC
CONTRACTOR CONSULTANT
TRIAL TEST NO 1
100
80
60
40
20
0
0.01 0.1 1 10 100
80
GRADING ( % Passing )
60
40
20
0
0.01 0.1 1 10 100
SIEVES ( mm )
DESIGN GRADING LOWER LIMIT UPPER LIMIT
AGGT SIZE 0.075 0.150 0.300 0.600 1.18 2.36 5.0 10.0 14.0 20.0 37.5
10mm 0.2 1.9 2.3 2.7 3.2 5.0 32.9 96.6 100.0 100.0 100.0
42
22
36
15
45
40
TRIAL TEST NO. 2
50.0
100.0
PROJECT : FISH TOWN HARPER ROAD
CONSULTANT : COMPTRAN ENGINEERING AND PLANNING ASSOCIATES.
CONTRACTOR : CHINA RAILWAY
SIEVE SIZE (mm) WT. RETAINED (g.) % RETAINED % PASSING % PASSING SPEC
37.5 0.0 0.0 100.0 100 100
25.0 32.0 1.0 99.0 99 90 - 100
20.0 853.0 27.3 71.7 72
14.0 1483.0 47.4 24.3 24
12.5 344.0 11.0 13.3 13 25 - 60
10.0 381.0 12.2 1.1 1
5.00 20.0 0.6 0.5 0 0 - 10
2.00 2.0 0.1 0.4 0 0-5
1.180 0.0 0.0 0.4 0
0.600 0.0 0.0 0.4 0
0.150 0.0 0.0 0.4 0
0.075 0.0 0.0 0.4 0
-0.075 13.0 0.4
TOTAL 3128.0
100
GRADING
80 ( % Passing Sieves )
60
DESIGN
GRAD.
40
LOWER
SPEC
20
0
2.00 20.00
SIEVES ( mm )
CONTRACTOR CONSULTANT
PROJECT : FISH TOWN HARPER ROAD
CONSULTANT : COMPTRAN ENGINEERING AND PLANNING ASSOCIATES.
CONTRACTOR : CHINA RAILWAY
SIEVE ANALYSIS
SIEVE SIZE (mm) WT. RETAINED (g.) % RETAINED % PASSING % PASSING SPEC
37.5 0.0 0.0 100.0 100 100
25.0 25.0 0.8 99.2 99 90 - 100
20.0 1016.0 32.1 67.1 67
14.0 1383.0 43.7 23.3 23
12.5 380.0 12.0 11.3 11 25 - 60
10.0 338.0 10.7 0.6 1
5.00 9.0 0.3 0.3 0 0 - 10
2.00 1.0 0.0 0.3 0 0-5
1.180 0.0 0.0 0.3 0
0.600 0.0 0.0 0.3 0
0.150 0.0 0.0 0.3 0
0.075 0.0 0.0 0.3 1
-0.075 10.0 0.3
TOTAL 3162.0
100
80 ( % Passing Sieves )
GRADING
60
DESIGN
GRAD.
40 LOWER
SPEC
20
0
2.00 20.00
SIEVES ( mm )
CONTRACTOR CONSULTANT
SIEVE ANALYSIS
SIEVE SIZE (mm) WT. RETAINED (g.) % RETAINED % PASSING % PASSING SPEC
37.5 0.0 0.0 100.0 100 100
25.0 28.5 0.9 99.1 99 90 - 100
20.0 934.5 29.7 69.4 69
14.0 1433.0 45.6 23.8 24
12.5 362.0 11.5 12.3 12 25 - 60
10.0 359.5 11.4 0.9 1
5.00 14.5 0.5 0.4 0 0 - 10
2.00 1.5 0.0 0.4 0 0-5
1.180 0.0 0.0 0.4 0
0.600 0.0 0.0 0.4 0
0.150 0.0 0.0 0.4 0
0.075 0.0 0.0 0.4 1
-0.075 11.5 0.4
TOTAL 3145.0
100
80 ( % Passing Sieves )
GRADING
60
DESIGN
GRAD.
40 LOWER
SPEC
20
0
2.00 20.00
SIEVES ( mm )
CONTRACTOR CONSULTANT.
WASHED
812
2316.0
KEYO ( CHICO )
SIEVE ANALYSIS
MOISTURE CONTENT
TECHNICIAN DATE : 18/11/2016
SAMPLE No TEST NO 1 BEFORE WASHING 1028.3
SAMPLE SIZE QUARRY SAND AFTER WASHING 916.5
SAMPLE SOURCE CHINA RAILWAY QUARRY INITIAL DRY WT. ( g) 1028
BS 882 (OVER ALL LIMITS )
SIEVE SIZE (mm) WT. RETAINED (g.) % RETAINED % PASSING % PASSING SPEC
50.0 0.0 0.0 100.0 100
37.5 0.0 0.0 100.0 100
20.0 0.0 0.0 100.0 100
14.0 0.0 0.0 100.0 100
10.0 0.0 0.0 100.0 100 100
5.0 17.4 1.7 98.3 98 89 - 100
2.36 201.5 19.6 78.7 79 60 - 100
1.18 136.7 13.3 65.4 65 30 - 100
0.600 201.3 19.6 45.8 46 15 - 100
0.300 175.1 17.0 28.8 29 5 - 70
0.150 100.5 9.8 19.0 19 0 - 15
0.075 84.1 8.2 10.9 11
-0.075 111.8 10.9
TOTAL 1028
100
80
GRADING ( % Passing Sieves )
60
DESIDN GRAD.
40 LOWER SPEC
UPPER SPEC
20
0
0.010 0.100 1.000 10.000 100.000
SIEVES ( mm )
CONTRACTOR CONSULTANT
PROJECT : FISH TOWN HARPER ROAD
CONSULTANT : COMPTRAN ENGINEERING AND PLANNING ASSOCIATES.
CONTRACTOR : CHINA RAILWAY
SIEVE ANALYSIS
SIEVE SIZE (mm) WT. RETAINED (g.) % RETAINED % PASSING % PASSING SPEC
50.0 0.0 0.0 100.0 100
37.5 0.0 0.0 100.0 100
20.0 0.0 0.0 100.0 100
14.0 0.0 0.0 100.0 100
10.0 1.5 0.1 99.9 100 100
5.0 26.6 2.0 97.9 98 89 - 100
2.36 322.9 23.9 74.0 74 60 - 100
1.18 170.2 12.6 61.4 61 30 - 100
0.600 244.0 18.1 43.3 43 15 - 100
0.300 215.1 15.9 27.4 27 5 - 70
0.150 126.4 9.4 18.0 18 0 - 15
0.075 107.0 7.9 10.1 10
-0.075 136.3 10.1
TOTAL 1350.1
100
80
GRADING ( % Passing Sieves )
60
DESIDN GRAD.
40 LOWER SPEC
UPPER SPEC
20
0
0.010 0.100 1.000 10.000 100.000
SIEVES ( mm )
CONTRACTOR CONSULTANT
PROJECT : FISH TOWN HARPER ROAD
CONSULTANT : COMPTRAN ENGINEERING AND PLANNING ASSOCIATES.
CONTRACTOR : CHINA RAILWAY
SIEVE ANALYSIS
SIEVE SIZE (mm) WT. RETAINED (g.) % RETAINED % PASSING % PASSING SPEC
50.0 0.0 0.0 100.0 100
37.5 0.0 0.0 100.0 100
20.0 0.0 0.0 100.0 100
14.0 0.0 0.0 100.0 100
10.0 1.5 0.1 99.9 100 100
5.0 35.3 1.9 98.0 98 89 - 100
2.36 423.7 22.7 75.3 75 60 - 100
1.18 238.6 12.8 62.5 63 30 - 100
0.600 344.6 18.5 44.0 44 15 - 100
0.300 302.6 16.2 27.8 28 5 - 70
0.150 176.7 9.5 18.3 18 0 - 15
0.075 149.1 8.0 10.3 10
-0.075 192.2 10.3
TOTAL 1864.2
100
80
GRADING ( % Passing Sieves )
60
DESIDN GRAD.
40 LOWER SPEC
UPPER SPEC
20
0
0.010 0.100 1.000 10.000 100.000
SIEVES ( mm )
CONTRACTOR CONSULTANT
SIEVES 0.150 0.300 0.600 1.18 2.36 5.0 10.0
DESIDN GRAD. 19 29 46 65 79 98 100
LOWER SPEC 0 5 15 30 60 89 100
UPPER SPEC 15 70 100 100 100 100 100
NMC
C 26
359.7
359.0
84.9
0.7
274.1
0.3
SIEVES 0.150 0.300 0.600 1.18 2.36 5.0 10.0
DESIDN GRAD. 18 27 43 61 74 98 100
LOWER SPEC 0 5 15 30 60 89 100
UPPER SPEC 15 70 100 100 100 100 100
SIEVES 0.150 0.300 0.600 1.18 2.36 5.0 10.0
DESIDN GRAD. 18 28 44 63 75 98 100
LOWER SPEC 0 5 15 30 60 89 100
UPPER SPEC 15 70 100 100 100 100 100
PROJECT : FISH TOWN - HARPER ROAD - MONROVIA
CONSULTANT : COMPTRAN ENGINEERING AND PLANNING ASSOCIATES.
CONTRACTOR : CHINA RAILWAY
SIEVE ANALYSIS
NMC DATE : 18/11/2016
TECHNICIAN BEFORE WASHING 1659.9
SAMPLE No TEST NO 1 AFTER WASHING 1628.3
SAMPLE SIZE PIT SAND INITIAL DRY WEIGHT 1660
SAMPLE SOURCE HAPER AIR FIELD
BS 882 (OVER ALL LIMITS )
SIEVE SIZE (mm) WT. RETAINED (g.) % RETAINED % PASSING % PASSING SPEC
50.0 0.0 0.0 100.0 100
37.5 0.0 0.0 100.0 100
20.0 0.0 0.0 100.0 100
14.0 0.0 0.0 100.0 100
10.0 0.0 0.0 100.0 100 100
5.0 0.9 0.1 99.9 100 89 - 100
2.36 15.4 0.9 99.0 99 60 - 100
1.18 81.7 4.9 94.1 94 30 - 100
0.600 511.8 30.8 63.3 63 15 - 100
0.300 755.6 45.5 17.7 18 5 - 70
0.150 229.2 13.8 3.9 4 0 - 15
0.075 33.8 2.0 1.9 2
-0.075 31.6 1.9
TOTAL 1659.9
100
80 ( % Passing Sieves )
GRADING
60
40
20
0
0.010 0.100 1.000 10.000 100.000
SIEVES ( mm )
CONTRACTOR CONSULTANT
PROJECT : FISH TOWN HARPER ROAD
CONSULTANT : COMPTRAN ENGINEERING AND PLANNING ASSOCIATES.
CONTRACTOR : CHINA RAILWAY
SIEVE ANALYSIS
NMC DATE : 18/11/2016
TECHNICIAN NMC BEFORE WASHING 1128.1
SAMPLE No TEST NO 2 AFTER WASHING 1118.5
SAMPLE SIZE PIT SAND INITIAL DRY WEIGHT 1128
SAMPLE SOURCE HAPER AIR FIELD
BS 882 (OVER ALL LIMITS )
SIEVE SIZE (mm) WT. RETAINED (g.) % RETAINED % PASSING % PASSING SPEC
50.0 0.0 0.0 100.0 100
37.5 0.0 0.0 100.0 100
20.0 0.0 0.0 100.0 100
14.0 0.0 0.0 100.0 100
10.0 0.0 0.0 100.0 100 100
5.0 0.0 0.0 100.0 100 89 - 100
2.36 12.1 1.1 98.9 99 60 - 100
1.18 60.7 5.4 93.5 94 30 - 100
0.600 347.7 30.8 62.7 63 15 - 100
0.300 518.4 46.0 16.8 17 5 - 70
0.150 155.3 13.8 3.0 3 0 - 15
0.075 24.3 2.2 0.9 1
-0.075 9.6 0.9
TOTAL 1128.1
100
80
60
40
20
0
0.010 0.100 1.000 10.000 100.000
CONTRACTOR CONSULTANT
SIEVE ANALYSIS
NMC
TECHNICIAN DATE : 18/11/2016
SAMPLE No AVERAGE TEST NO 1 & 2 BEFORE WASHING 1394.0
SAMPLE SIZE PIT SAND AFTER WASHING 1373.4
SAMPLE SOURCE HAPER AIR FIELD INITIAL DRY WEIGHT 1394
BS 882 (OVER ALL LIMITS )
SIEVE SIZE (mm) WT. RETAINED (g.) % RETAINED % PASSING % PASSING SPEC
50.0 0.0 0.0 100.0 100
37.5 0.0 0.0 100.0 100
20.0 0.0 0.0 100.0 100
14.0 0.0 0.0 100.0 100
10.0 0.0 0.0 100.0 100 100
5.0 0.4 0.0 100.0 100 89 - 100
2.36 13.8 1.0 99.0 99 60 - 100
1.18 71.2 5.1 93.9 94 30 - 100
0.600 429.7 30.8 63.0 63 15 - 100
0.300 637.0 45.7 17.3 17 5 - 70
0.150 192.2 13.8 3.6 4 0 - 15
0.075 29.0 2.1 1.5 1
-0.075 20.6 1.5
TOTAL 1394.0
100
80
GRADING ( % Passing Sieves )
60
40
20
0
0.010 0.100 1.000 10.000 100.000
SIEVES ( mm )
SIEVES ( mm )
CONTRACTOR CONSULTANT
NMC
C 26
359.7
359
84.9
0.7
274.1
0.3