You are on page 1of 48

Error Code

Refrigerator

1
Product Type

FDR-3Room FDR2Room 4 Door FDR SBS

Error Display Type

2
FDR - 3 Room - Type

A-Error Code
If "Freezer" Key + "Fridge" Key are
pressed simultaneously
for 8 seconds, the error mode by
self-diagnosis will be canceled.

E-Error Code
If Energy Saver Key + Lighting Key
are pressed simultaneously
for 8 seconds, the error mode by
self-diagnosis will be canceled.

3
Code Item Check Parts Trouble contents Image-1 Image-2

Display error : separation of sensor housing


part, contact error, disconnection, short
Freezer Room Sensor circuit.
Freezer Room Sensor
Error Display error of detecting temperature of
sensor : more than 149F(+65C) or less than
-58F(-50C)

Display error : separation of sensor housing


part, contact error, disconnection, short
Fridge Room Sensor circuit.
Fridge Room Sensor
Error Display error of detecting temperature of
sensor : more than 149F(+65C) or less than
-58F(-50C)

Display error : separation of sensor housing


part, contact error, disconnection, short
Freezer-Defrost-Sensor circuit.
Freezer-Defrost-Sensor
Error Display error of detecting temperature of
sensor : more than 149F(+65C) or less than
-58F(-50C)

Display error : separation of sensor housing


part, contact error, disconnection, short
Fridge-Defrost-Sensor circuit.
Fridge-Defrost-Sensor
Error Display error of detecting temperature of
sensor : more than 149(+65) or less
than -58(-50)

Display error : separation of sensor housing


part, contact error, disconnection, short
circuit.
Ambient-Sensor Error Ambient-Sensor
Display error of detecting temperature of
sensor : more than 149F(+65C) or less than
-58F(-50C)

4
Display error : separation of sensor housing
part, contact error, disconnection, short
Ice Maker(FZ) Sensor
ASSY Ice Maker(FZ) circuit Display error
Error
of detecting temperature of sensor: more
than 149 (+65C) or less than -58(-50C)

Sensor housing removal, poor contact, power


cord disconnection, short circuit or voltage
defects
Humidity-Sensor Error Humidity-Sensor
are detected by the sensors. Defect is
displayed if voltage is 0.8V or lower of 4.1V
or higher.

Display error : separation of sensor housing


part, contact error, disconnection, short
Ice Maker (Fridge) circuit.
ASSY Ice Maker (Fridge)
Sensor Error Display error of detecting temperature of
sensor : more than 149(+65C) or less than
-58(-50C)

Display error : separation of sensor housing


part, contact error, disconnection, short
circuit.
Ice Room Sensor Error Ice Room Sensor
Display error of detecting temperature of
sensor : more than 149(+65C) or less than
-58(-50C)

Connector Slipped-Out or Open-Contact,


Sparkling-Tank Temp
Wire Cut or Short-Circuited, Abnormal
Sensor ASSY CASE BASKET-UP
Sensing Temp : higher than 149(+65) or
Error
lower than -58(-50)

5
Display error during operation of applicable
Freezer Room FAN Error Freezer Room FAN BLDC fan motor : Feed back signal line contact
error, motor wire separation, motor error

Poor contact of feedback signal line, motor


line disconnection or motor defect during
Fridge Room FAN Error Fridge Room FAN BLDC
operation
of fan motor indicated as error

Display error during operation of applicable


Condenser-FAN Error Condenser-FAN BLDC fan motor : Feed back signal line contact
error, motor wire separation, motor error

Housing removal, poor contact, power cable


disconnection, short circuit, or temperature
fuse defect
1. Freezer-Defrost-Heater
relevant to defrosting heater. Refrigerating
Freezer Defrosting Error 2. Freezer-Defrost Sensor
in wrong conditions, Freezing compartment
3. Main PBA
defrosting not
completed even upon heating continuous
for 80 min and 120min.
Housing removal, poor contact, power cable
disconnection, short circuit, or temperature
fuse defect
1. Fridge-Defrost-Heater
relevant to defrosting heater. Refrigerating
Fridge Defrosting Error 2. Fridge-Defrost Sensor
in wrong conditions, Freezing compartment
3. Main PBA
defrosting not
completed even upon heating continuous
for 80 min and 120min.

6
Damper heater housing removal, poor
Flex Room Damper contact and cable disconnection detected by
MOTOR DC-DAMPER
Heater Error the damper heater as open error, and defects
are displayed.

Earlier restoration of 1. Cooling Cycle Check Defect is displayed if heating for F-


Freeze Room Defrosting 2. Freeze Defroster compartment defrosting is terminated within
Error Sensor 5 minutes.

Earlier restoration of 1. Cooling Cycle Check Defect is displayed if heating for R-


Fridge Room 2. Fridge Defroster compartment defrosting is terminated within
Defrosting Error Sensor 5 minutes.

1. Ice Maker(Fridge Display error when open error is detected by


Ice Maker(Fridge) Room) Heater : separation of Ice Pipe Heater
Function Error - Heater housing part,
- Ice Water supply Line contact error, disconnection, short circuit.

Display error when the Ice Maker(FZ) kit


Ice Room-FAN Error Ice Room Fan-BLDC operate moving ice over 3 times or it is
not leveled.

7
Display pc - Er in the panel with alarm :
Panel PBA Main PBA 1. Panel PBA
MICOM MAIN PANEL communication
Communication Error 2. Main PBA
error.

Display 44Er in the panel :


Main PBA - Inverter PBA 1. Inverter PBA
Inverter MICOM Main MICOM
Communication Error 2. Main PBA
communication error.

Connector Slipped-Out or Open-Contact,


Ice Room Drain Heater ASSY CASE-FAN AUGER
Wire Cut or Short-Circuited, Defective
Open Error MOTOR
Thermistor

Connector Slipped-Out or Open-Contact,


Ice Room Wall Heater
Wire Cut or Short-Circuited, Defective
Open Error
Thermistor

If temperature in the freezing compartment


Abnormal high
rises to abnormal level or the door is kept
temperature in freezing 1. Cooling Cycle Check
for an extended period of time, the display of
compartment Blinking
the freezing compartment blinks.

8
If temperature in the cold compartment rises
Abnormal high
to abnormal level or the door is kept for an
temperature in cold 1. Cooling Cycle Check
extended period of time, the display of the
compartment Blinking
cold compartment blinks.

Comp starting Failure Defect is displayed if the compressor startup


1. Inverter PBA
Error fails.

Comp Inveter PBA IPM Defect is displayed upon the compressor IPM
1. Inverter PBA
Fault Error fault error.

Compressor Abnormal Defect is displayed if the compressor


1. Inverter PBA
current Detection Error abnormal current is detected.

Compressor motor
Defect is displayed upon the compressor
Locked or Over RPM 1. Inverter PBA
motor constraint.
Error

9
Compressor under Defect is displayed upon the compressor low
1. Inverter PBA
voltage Error voltage error.

Comp over voltage Defect is displayed upon the compressor


1. Inverter PBA
Eroor overvoltage error.

Display error when open error is detected by


sparkling tank overflow : separation of
Sparkling Tank Overflow Flower Sensor
Sparkling Tank Overflow Sensor housing part,
contact error, disconnection, short circuit.

Display error when open error is detected by


water supply to sparkling tank error :
Water Supply to
seperation of Sparkling Tank Water Level
Sparkling Tank Error
Sensor housing part, contact error,
disconnection, short circuit.

10
FDR 2 Room - Type

A-Error Code
If "Freezer" Key + "Fridge" Key are
pressed simultaneously
for 8 seconds, the error mode by
self-diagnosis will be canceled.

B-Error Code
Energy Saver Key + ALAM Key are
pressed simultaneously
for 8 seconds, the error mode by
self-diagnosis will be canceled.

E-Error Code
If Energy Saver Key + Lighting Key
are pressed simultaneously
for 8 seconds, the error mode by
self-diagnosis will be canceled.

11
Code Item Check Parts Trouble contents Image-1 Image-2

Display error : separation of sensor housing


part, contact error, disconnection, short
Freezer Room Sensor circuit.
Freezer Room Sensor
Error Display error of detecting temperature of
sensor : more than 149F(+65C) or less than
-58F(-50C)

Display error : separation of sensor housing


part, contact error, disconnection, short
Fridge Room Sensor circuit.
Fridge Room Sensor
Error Display error of detecting temperature of
sensor : more than 149F(+65C) or less than
-58F(-50C)

Display error : separation of sensor housing


part, contact error, disconnection, short
Freezer-Defrost-Sensor circuit.
Freezer-Defrost-Sensor
Error Display error of detecting temperature of
sensor : more than 149F(+65C) or less than
-58F(-50C)

Display error : separation of sensor housing


part, contact error, disconnection, short
Fridge-Defrost-Sensor circuit.
Fridge-Defrost-Sensor
Error Display error of detecting temperature of
sensor : more than 149(+65) or less
than -58(-50)

Display error : separation of sensor housing


part, contact error, disconnection, short
circuit.
Ambient-Sensor Error Ambient-Sensor
Display error of detecting temperature of
sensor : more than 149F(+65C) or less than
-58F(-50C)

12
Display error : separation of sensor housing
part, contact error, disconnection, short
circuit.
Pantry Room Sensor Pantry Room Sensor
Display error of detecting temperature of
sensor : more than 149(+65) or less
than -58(-50)

Display error : separation of sensor housing


part, contact error, disconnection, short
Ice Maker(FZ) Sensor
ASSY Ice Maker(FZ) circuit Display error
Error
of detecting temperature of sensor: more
than 149 (+65C) or less than -58(-50C)

Sensor housing removal, poor contact, power


cord disconnection, short circuit or voltage
defects
Humidity-Sensor Error Humidity-Sensor
are detected by the sensors. Defect is
displayed if voltage is 0.8V or lower of 4.1V
or higher.

Display error : separation of sensor housing


part, contact error, disconnection, short
Ice Maker (Fridge) circuit.
ASSY Ice Maker (Fridge)
Sensor Error Display error of detecting temperature of
sensor : more than 149(+65C) or less than
-58(-50C)

Display error : separation of sensor housing


part, contact error, disconnection, short
circuit.
Ice Room Sensor Error Ice Room Sensor
Display error of detecting temperature of
sensor : more than 149(+65C) or less than
-58(-50C)

13
Display error during operation of applicable
Freezer Room FAN Error Freezer Room FAN BLDC fan motor : Feed back signal line contact
error, motor wire separation, motor error

Poor contact of feedback signal line, motor


line disconnection or motor defect during
Fridge Room FAN Error Fridge Room FAN BLDC
operation
of fan motor indicated as error

Display error during operation of applicable


Condenser-FAN Error Condenser-FAN BLDC fan motor : Feed back signal line contact
error, motor wire separation, motor error

Housing removal, poor contact, power cable


disconnection, short circuit, or temperature
fuse defect
1. Freezer-Defrost-Heater
relevant to defrosting heater. Refrigerating
Freezer Defrosting Error 2. Freezer-Defrost Sensor
in wrong conditions, Freezing compartment
3. Main PBA
defrosting not
completed even upon heating continuous
for 80 min and 120min.
Housing removal, poor contact, power cable
disconnection, short circuit, or temperature
fuse defect
1. Fridge-Defrost-Heater
relevant to defrosting heater. Refrigerating
Fridge Defrosting Error 2. Fridge-Defrost Sensor
in wrong conditions, Freezing compartment
3. Main PBA
defrosting not
completed even upon heating continuous
for 80 min and 120min.
14
When the Freezer Ice Maker error occurs
Ice Maker(FZ) Function
Assy Ice Maker(FZ) more than 3 times, the error will be
Error
displayed.

Damper heater housing removal, poor


Fridge Room Damper contact and cable disconnection detected by
MOTOR DC-DAMPER
Heater Error the damper heater as open error, and defects
are displayed.

The error occurs when there is a wire


Freezer-Ice Pipe Heater connector slip-out of the Water Supply Pipe
ASSY-PIPE WATER FRE
Error Heater, a contact error or a breakage in the
wiring.

Earlier restoration of 1. Cooling Cycle Check Defect is displayed if heating for F-


Freeze Room Defrosting 2. Freeze Defroster compartment defrosting is terminated within
Error Sensor 5 minutes.

Earlier restoration of 1. Cooling Cycle Check Defect is displayed if heating for R-


Fridge Room 2. Fridge Defroster compartment defrosting is terminated within
Defrosting Error Sensor 5 minutes.

15
Display error when open error is detected by
Ice Maker(FF) Function Ice Maker(Fridge Room) Heater : separation of Ice Pipe Heater
Error Function Error housing part,
contact error, disconnection, short circuit.

Display error when the Ice Maker(Fridge) kit


Ice Room-FAN Error Ice Room Fan-BLDC operate moving ice over 3 times or it is
not leveled.

Display pc - Er in the panel with alarm :


Panel PBA Main PBA 1. Panel PBA
MICOM MAIN PANEL communication
Communication Error 2. Main PBA
error.

Display 44Er in the panel :


Main PBA - Inverter PBA 1. Inverter PBA
Inverter MICOM Main MICOM
Communication Error 2. Main PBA
communication error.

Display error when open error is detected by


Ice Room Drain Heater ice Maker drain duct heater : separation of
Auger motor
Open Error Ice Duct Heater housing part, contact error,
disconnection, short circuit.

16
Connector Slipped-Out or Open-Contact,
Ice Room Wall Heater
Ice Room Wall Heater Wire Cut or Short-Circuited, Defective
Open Error
Thermistor

If temperature in the freezing compartment


Abnormal high
rises to abnormal level or the door is kept
temperature in freezing 1. Cooling Cycle Check
for an extended period of time, the display of
compartment Blinking
the freezing compartment blinks.

If temperature in the cold compartment rises


Abnormal high
to abnormal level or the door is kept for an
temperature in cold 1. Cooling Cycle Check
extended period of time, the display of the
compartment Blinking
cold compartment blinks.

Comp starting Failure Defect is displayed if the compressor startup


1. Inverter PBA
Error fails.

Comp Inveter PBA IPM Defect is displayed upon the compressor IPM
1. Inverter PBA
Fault Error fault error.

17
Compressor Abnormal Defect is displayed if the compressor
1. Inverter PBA
current Detection Error abnormal current is detected.

Compressor motor
Defect is displayed upon the compressor
Locked or Over RPM 1. Inverter PBA
motor constraint.
Error

Compressor under Defect is displayed upon the compressor low


1. Inverter PBA
voltage Error voltage error.

Comp over voltage Defect is displayed upon the compressor


1. Inverter PBA
Eroor overvoltage error.

18
4 Door - Type

C-Error Code
If Freezer + Control Lock are pressed
simultaneously
for 8 seconds, the error mode by
self-diagnosis will be canceled.

F-Error Code
If CoolSelect+ Key + Energy Saver
are pressed simultaneously
for 8 seconds, the error mode by
self-diagnosis will be canceled.

19
LED Item Check Parts Trouble contents Image-1 Image-2

The sensor housing separating, incomplete


contact, open-circuited wire, short-circuit and
Freezer Room Sensor
Freezer Room Sensor abnormal temperature errors are displayed
Error
when the temperature measured by the
sensor is +50 or higher or -50 or lower.

The sensor housing separating, incomplete


contact, open-circuited wire, short-circuit and
Fridge Room Sensor
Fridge Room Sensor abnormal temperature errors are displayed
Error
when the temperature measured by the
sensor is +50 or higher or -50 or lower.

The sensor housing separating, incomplete


contact, open-circuited wire, short-circuit and
Freezer-DEF-Sensor
Freezer-DEF-Sensor abnormal temperature errors are displayed
Error
when the temperature measured by the
sensor is +50 or higher or -50 or lower.

The sensor housing separating, incomplete


contact, open-circuited wire, short-circuit and
Fridge-DEF-Sensor Error Fridge-DEF-Sensor abnormal temperature errors are displayed
when the temperature measured by the
sensor is +50 or higher or -50 or lower.

The sensor housing separating, incomplete


contact, open-circuited wire, short-circuit and
Ambient-Sensor Error Ambient-Sensor abnormal temperature errors are displayed
when the temperature measured by the
sensor is +50 or higher or -50 or lower.

20
The sensor housing separating, incomplete
contact, open-circuited wire, short-circuit and
Pantry Room Sensor
Pantry Room Sensor abnormal temperature errors are displayed
Error
when the temperature measured by the
sensor is +50 or higher or -50 or lower.

The sensor housing separating, incomplete


contact, open-circuited wire, short-circuit and
Cool Select Room
Cool Select Room Sensor abnormal temperature errors are displayed
sensor Error
when the temperature measured by the
sensor is +50 or higher or -50 or lower.

The sensor housing separating, incomplete


contact, open-circuited wire, short-circuit and
Cool Select Room-DEF Cool Select Room DEF-
abnormal temperature errors are displayed
sensor Error Sensor
when the temperature measured by the
sensor is +50 or higher or -50 or lower.

This error is displayed while the


corresponding fan motor is operating and a
Humidity-Sensor Error Humidity-Sensor
feedback signal line contact error, motor
wire separation or motor error occurs.

Connector Slipped-Out or Open-Contact,


Ice Maker (Fridge) Wire Cut or Short-Circuited, Abnormal
ASSY Ice Maker (Fridge)
Sensor Error Sensing Temp : higher than 149(+65) or
lower than -58(-50)

21
Connector Slipped-Out or Open-Contact,
Wire Cut or Short-Circuited, Abnormal
Ice Room Sensor Error Ice Room Sensor
Sensing Temp : higher than 149(+65) or
lower than -58(-50)

This error is displayed while the


Fridge Room humidity Fridge Room humidity corresponding fan motor is operating and a
sensor Error sensor feedback signal line contact error, motor
wire separation or motor error occurs.

Connector Slipped-Out or Open-Contact,


Sparkling-Tank Temp
Wire Cut or Short-Circuited, Abnormal
Sensor ASSY CASE BASKET-UP
Sensing Temp : higher than 149(+65) or
Error
lower than -58(-50)

The error is displayed while the


corresponding fan motor is operating and a
Freezer Room FAN Error Freezer Room FAN BLDC
feedback signal line contact error, motor
wire separation or motor error occurs.

The error is displayed while the


corresponding fan motor is operating and a
Fridge Room FAN Error Fridge Room FAN BLDC
feedback signal line contact error, motor
wire separation or motor error occurs.

22
The error is displayed while the
corresponding fan motor is operating and a
Condenser-FAN Error Condenser-FAN BLDC
feedback signal line contact error, motor
wire separation or motor error occurs.

The separation of the freezer compartment


defrosting heater housing part, contact error,
disconnection, short circuit or temperature
1. Freezer-DEF-Heater
fuse error. One of these error codes is
Freezer Defrosting Error 2. Freezer-Defrost Sensor
displayed if the defrosting operation of the
3. Main PBA
freezer or Cool Select Room does not finish
even after the continuous heating operation
has been performed for 120 minutes.
The separation of the freezer compartment
defrosting heater housing part, contact error,
disconnection, short circuit or temperature
1. CF-DEF-Heater
Cool Select Room fuse error. One of these error codes is
2. Freezer-Defrost Sensor
defrosting Error displayed if the defrosting operation of the
3. Main PBA
freezer or Cool Select Room does not finish
even after the continuous heating operation
has been performed for 120 minutes.

One of these error codes is displayed in case


Cool Select Room Fan of the feedback signal line contact error, the
Error motor wire separation or the motor error
when the fan motor starts to run.

Earlier restoration of Defect is displayed if heating for Freezer


Freezer Room Cooling System check Room defrosting is terminated within 5
Defrosting Error minutes.

23
Earlier restoration of Defect is displayed if heating for Cool Select
Cool Select Room Cooling System check Room defrosting is terminated within 5
Defrosting Error minutes.

It occurs when there is a defect in removing


Ice Maker (Fridge) ice cubes or in making it paralleled [ When
ASSY Ice Maker (Fridge)
Function Error there is an error while doing self-diagnosis of
the Initial Motor Rotation.]

When the related Fan Motor operates, it


ASSY CASE-FAN AUGER occurs if the contact of the Feed Back Signal
Ice Room-FAN Error
MOTOR Wire is defective, the Motor Wire is slipped
out or the Motor is defective.

Panel PBA Main PBA 1. Panel PBA A communications error between the Main
Communication Error 2. Main PBA and the Panel PCBs

Main PBA - Inverter Display 44E in the panel :


1. Inverter PBA
PBA F Comp. Inverter MICOM Main MICOM
2. Main PBA
Communication Error communication error.

24
Main R Comp. Display 45E in the panel :
Inverter Inverter PBA R Comp. Inverter MICOM Main MICOM
Communication Error communication error.

MainDispenser Panel A communications error between the Main


Panel PBA
Error and the Dispenser Panel PCBs

Connector Slipped-Out or Open-Contact,


Ice Room Drain Heater ASSY CASE-FAN AUGER
Wire Cut or Short-Circuited, Defective
Open Error MOTOR
Thermistor

The error is displayed while the


corresponding fan motor is operating and a
Chef Pantry Fan Error Fan BLDC
feedback signal line contact error, motor
wire separation or motor error occurs

Connector Slipped-Out or Open-Contact,


Ice Room Wall Heater
Wire Cut or Short-Circuited, Defective
Open Error
Thermistor

25
Door Handle Heater
Door Heater Door Handle Heater Open Error
Error

When the freezer temperature is abnormally


Abnormal high
high or the freezer door is open for a certain
temperature in freezing 1. Cooling Cycle Check
period of time and the freezer temperature
compartment Blinking
increases, the freezer display blinks.

When the freezer temperature is abnormally


Abnormal high
high or the fridge door is open for a certain
temperature in fridge 1. Cooling Cycle Check
period of time and the fridge temperature
compartment Blinking
increases, the fridge display blinks.

Abnormal high When the freezer temperature is abnormally


temperature in cool high or the freezer door is open for a certain
1. Cooling Cycle Check
select room period of time and the fridge temperature
compartment Blinking increases, the cool select display blinks.

F Comp start failure The error code is displayed when the


Inverter PBA
error compressor has failed to start.

26
F Comp Inveter PBA The error code is displayed when the
Inverter PBA
IPM Fault Error compressor IPM fault error has occurred.

F Compressor Abnormal The error code is displayed when the


Inverter PBA
current Detection Error compressor location detection failed.

F Compressor motor
The error code is displayed when the
Locked or Over RPM Inverter PBA
compressor motor is constrained.
Error

F Compressor under The error code is displayed when the AC


Inverter PBA
voltage Error Input Voltage is too low.

F Comp over voltage The error code is displayed when the AC


Inverter PBA
Eroor Input Voltage is too high.

27
R Comp starting Failure The error code is displayed when the
Inverter PBA
Error compressor has failed to start.

R Comp Inveter PBA The error code is displayed when the


Inverter PBA
IPM Fault Error compressor IPM fault error has occurred.

R Compressor This error code is displayed when an


Abnormal current Inverter PBA abnormal current is detected in the
Detection Error compressor.

R Compressor motor
The error code is displayed when the
Locked or Over RPM Inverter PBA
compressor motor is constrained.
Error

R Compressor under The error code is displayed when the AC


Inverter PBA
voltage Error Input Voltage is too low.

28
R Comp over voltage The error code is displayed when the AC
Inverter PBA
Eroor Input Voltage is too high.

Display error when open error is detected by


Sparkling Tank sparkling tank overflow : separation of
Flower Sensor
Overflow Sparkling Tank Overflow Sensor housing part,
contact error, disconnection, short circuit.

Display error when open error is detected by


water supply to sparkling tank error :
Water Supply to
seperation of Sparkling Tank Water Level
Sparkling Tank Error
Sensor housing part, contact error,
disconnection, short circuit.

29
FDR - Type

A-Error Code (Page 30~35)


If Power Freeze Key + Power Cool Key
are pressed simultaneously for 8
seconds,
the error mode by self-diagnosis will be
canceled.

B-Error Code (Page 36~37)

If Ice Off+Aram or Energy Key are


pressed simultaneously for 8 seconds,
the error mode by self-diagnosis will be
canceled.

30
Code Item Check Parts Trouble contents Image-1 Image-2

Display error : separation of sensor housing


part, contact error, disconnection, short
Freezer Room Sensor circuit.
Freezer Room Sensor
Error Display error of detecting temperature of
sensor : more than 149F(+65C) or less than
-58F(-50C)

Display error : separation of sensor housing


part, contact error, disconnection, short
Fridge Room Sensor circuit.
Fridge Room Sensor
Error Display error of detecting temperature of
sensor : more than 149F(+65C) or less than
-58F(-50C)

Display error : separation of sensor housing


part, contact error, disconnection, short
Freezer-Defrost-Sensor circuit.
Freezer-Defrost-Sensor
Error Display error of detecting temperature of
sensor : more than 149F(+65C) or less than
-58F(-50C)

Display error : separation of sensor housing


part, contact error, disconnection, short
Fridge-Defrost-Sensor circuit.
Fridge-Defrost-Sensor
Error Display error of detecting temperature of
sensor : more than 149(+65) or less
than -58(-50)

Display error : separation of sensor housing


part, contact error, disconnection, short
circuit.
Ambient-Sensor Error Ambient-Sensor
Display error of detecting temperature of
sensor : more than 149F(+65C) or less than
-58F(-50C)

31
Display error : separation of sensor housing
part, contact error, disconnection, short
circuit.
Pantry Room Sensor Pantry Room Sensor
Display error of detecting temperature of
sensor : more than 149(+65) or less
than -58(-50)

Display error : separation of sensor housing


part, contact error, disconnection, short
Ice Maker(FZ) Sensor
ASSY Ice Maker(FZ) circuit Display error
Error
of detecting temperature of sensor: more
than 149 (+65C) or less than -58(-50C)

Sensor housing removal, poor contact, power


cord disconnection, short circuit or voltage
defects
Humidity-Sensor Error Humidity-Sensor
are detected by the sensors. Defect is
displayed if voltage is 0.8V or lower of 4.1V
or higher.

Display error during operation of applicable


Freezer Room FAN Error Freezer Room FAN BLDC fan motor : Feed back signal line contact
error, motor wire separation, motor error

Poor contact of feedback signal line, motor


line disconnection or motor defect during
Fridge Room FAN Error Fridge Room FAN BLDC
operation
of fan motor indicated as error

32
Display error during operation of applicable
Condenser-FAN Error Condenser-FAN BLDC fan motor : Feed back signal line contact
error, motor wire separation, motor error

Housing removal, poor contact, power cable


disconnection, short circuit, or temperature
fuse defect
1. Freezer-Defrost-Heater
relevant to defrosting heater. Refrigerating
Freezer Defrosting Error 2. Freezer-Defrost Sensor
in wrong conditions, Freezing compartment
3. Main PBA
defrosting not
completed even upon heating continuous
for 80 min and 120min.
Housing removal, poor contact, power cable
disconnection, short circuit, or temperature
fuse defect
1. Fridge-Defrost-Heater
relevant to defrosting heater. Refrigerating
Fridge Defrosting Error 2. Fridge-Defrost Sensor
in wrong conditions, Freezing compartment
3. Main PBA
defrosting not
completed even upon heating continuous
for 80 min and 120min.

When the Freezer Ice Maker error occurs


Ice Maker(FZ) Function
Assy Ice Maker(FZ) more than 3 times, the error will be
Error
displayed.

Damper heater housing removal, poor


Fridge Room Damper contact and cable disconnection detected by
MOTOR DC-DAMPER
Heater Error the damper heater as open error, and defects
are displayed.

33
The error occurs when there is a wire
Freezer-Ice Pipe Heater connector slip-out of the Water Supply Pipe
ASSY-PIPE WATER FRE
Error Heater, a contact error or a breakage in the
wiring.

Earlier restoration of 1. Cooling Cycle Check Defect is displayed if heating for F-


Freeze Room Defrosting 2. Freeze Defroster compartment defrosting is terminated within
Error Sensor 5 minutes.

Earlier restoration of 1. Cooling Cycle Check Defect is displayed if heating for R-


Fridge Room 2. Fridge Defroster compartment defrosting is terminated within
Defrosting Error Sensor 5 minutes.

Display pc - Er in the panel with alarm :


Panel PBA Main PBA 1. Panel PBA
MICOM MAIN PANEL communication
Communication Error 2. Main PBA
error.

Main PBA - Inverter Display 44Er in the panel :


1. Inverter PBA
PBA Inverter MICOM Main MICOM
2. Main PBA
Communication Error communication error.

34
If temperature in the freezing compartment
Abnormal high
rises to abnormal level or the door is kept
temperature in freezing 1. Cooling Cycle Check
for an extended period of time, the display
compartment Blinking
of the freezing compartment blinks.

If temperature in the cold compartment rises


Abnormal high
to abnormal level or the door is kept for an
temperature in cold 1. Cooling Cycle Check
extended period of time, the display of the
compartment Blinking
cold compartment blinks.

Comp starting Failure Defect is displayed if the compressor startup


1. Inverter PBA
Error fails.

Comp Inveter PBA IPM Defect is displayed upon the compressor IPM
1. Inverter PBA
Fault Error fault error.

Compressor Abnormal Defect is displayed if the compressor


1. Inverter PBA
current Detection Error abnormal current is detected.

35
Compressor motor
Defect is displayed upon the compressor
Locked or Over RPM 1. Inverter PBA
motor constraint.
Error

Compressor under Defect is displayed upon the compressor low


1. Inverter PBA
voltage Error voltage error.

Comp over voltage Defect is displayed upon the compressor


1. Inverter PBA
Eroor overvoltage error.

36
Code Item Check Parts Trouble contents Image-1 Image-2
Left-Display-
Display error : In case of separation of sensor
housing parts, contact error, disconnection,
short circuit.
Ambient-Sensor Error Ambient-Sensor
Display error by temperature : When the
sensing temperature is more than 65
(149) or less than -50(-58).

Left-Display-
Display error : In case of separation of sensor
housing parts, contact error, disconnection,
Freezer Room Sensor short circuit.
Freezer Room Sensor
Error Display error by temperature : When the
sensing temperature is more than 65
(149) or less than -50(-58).

Left-Display-
Display error : In case of separation of sensor
housing parts, contact error, disconnection,
Freezer-DEF-Sensor short circuit.
Freezer-DEF-Sensor
Error Display error by temperature : When the
sensing temperature is more than 65
(149) or less than -50(-58).

Left-Display-

Display error : In case of Feed Back signal


Line contact error, separation of motor wire,
Freezer Room FAN Error Freezer Room FAN BLDC
Motor itself error during operation of
applicable fan motor.

Left-Display-

Display error : In case of Feed Back signal


Line contact error, separation of motor wire,
Condenser-FAN Error Condenser-FAN BLDC
motor itself error during operation of
applicable fan motor.

37
Left-Display-

Separation of sensor
Humidity-Sensor Error Humidity-Sensor housing part, contact error,
disconnection, short circuit

Left-Display- Display error : In case of separation of


defrost heater housing, contact error,
disconnection, short circuit or temperature
1. Freezer-DEF-Heater
fuse error.
Freezer Defrosting Error 2. Freezer-Defrost Sensor
Display error : If defrost does not finish
3. Main PBA
though the defrost of freeze compartment is
heating continuously for more than 70
minutes.
Right-Display-
Display error : In case of Separation of sensor
housing part, contact error, disconnection,
Ice Maker(FZ) Sensor short circuit.
Assy Ice Maker
Error Display error by temperature : when the
sensing temperature is more than 65
(149) or less than -50(-58).

Right-Display-
Check if there is a short between compressor
terminals.
Compressor Error Inverter PBA Check if there is a short between IPM Pins.
Check the Compressor and the Cycle Turn
Off the Ref. , after 5minutes, Turn on the Ref.

Right-Display-
Display error : In case of separation of sensor
housing parts, contact error, disconnection,
Fridge Room Sensor short circuit.
Fridge Room Sensor
Error Display error by temperature : When the
sensing temperature is more than 65
(149) or less than -50(-58).

38
SBS - Type

A-Error Code (Page 39~44)

If "Freezer" Key + "Fridge" Key are


pressed simultaneously
for 8 seconds, the error mode by self-
diagnosis will be canceled.

B-Error Code (Page 45~47)

If Energy Saver Key + Lighting Key are


pressed simultaneously
for 8 seconds, the error mode by self-
diagnosis will be canceled.

39
Code Item Check Parts Trouble contents Image-1 Image-2

Display error : separation of sensor housing


part, contact error, disconnection, short
Freezer Room Sensor circuit.
Freezer Room Sensor
Error Display error of detecting temperature of
sensor : more than 149F(+65C) or less than
-58F(-50C)

Display error : separation of sensor housing


part, contact error, disconnection, short
Fridge Room Sensor circuit.
Fridge Room Sensor
Error Display error of detecting temperature of
sensor : more than 149F(+65C) or less than
-58F(-50C)

Display error : separation of sensor housing


part, contact error, disconnection, short
Freezer-DEF-Sensor circuit.
Freezer-DEF-Sensor
Error Display error of detecting temperature of
sensor : more than 149F(+65C) or less than
-58F(-50C)

Display error : separation of sensor housing


part, contact error, disconnection, short
circuit.
Fridge-DEF-Sensor Error Fridge-DEF-Sensor
Display error of detecting temperature of
sensor : more than 149(+65) or less
than -58(-50)

Display error : separation of sensor housing


part, contact error, disconnection, short
circuit.
Ambient-Sensor Error Ambient-Sensor
Display error of detecting temperature of
sensor : more than 149F(+65C) or less than
-58F(-50C)

40
Display error : separation of sensor housing
part, contact error, disconnection, short
Cool Select Room circuit.
Flex Room Sensor
Sensor Error Display error of detecting temperature of
sensor : more than 149(+65) or less
than -58(-50)

Display error : separation of sensor housing


part, contact error, disconnection, short
Ice Maker(FZ) Sensor
ASSY Ice Maker(FZ) circuit Display error
Error
of detecting temperature of sensor: more
than 149 (+65C) or less than -58(-50C)

Sensor housing removal, poor contact, power


cord disconnection, short circuit or voltage
defects
Humidity-Sensor Error Humidity-Sensor
are detected by the sensors. Defect is
displayed if voltage is 0.8V or lower of 4.1V
or higher.

Display error during operation of applicable


Freezer Room FAN Error Freezer Room FAN BLDC fan motor : Feed back signal line contact
error, motor wire separation, motor error

Poor contact of feedback signal line, motor


line disconnection or motor defect during
Fridge Room FAN Error Fridge Room FAN BLDC
operation
of fan motor indicated as error

41
Display error during operation of applicable
Condenser-FAN Error Condenser-FAN BLDC fan motor : Feed back signal line contact
error, motor wire separation, motor error

Housing removal, poor contact, power cable


disconnection, short circuit, or temperature
fuse defect
1. Freezer-DEF-Heater
relevant to defrosting heater. Refrigerating
Freezer Defrosting Error 2. Freezer-Defrost Sensor
in wrong conditions, Freezing compartment
3. Main PBA
defrosting not
completed even upon heating continuous
for 80 min and 120min.
Housing removal, poor contact, power cable
disconnection, short circuit, or temperature
fuse defect
1. Fridge-DEF-Heater
relevant to defrosting heater. Refrigerating
Fridge Defrosting Error 2. Fridge-Defrost Sensor
in wrong conditions, Freezing compartment
3. Main PBA
defrosting not
completed even upon heating continuous
for 80 min and 120min.

When the Freezer Ice Maker error occurs


Ice Maker(FZ) Function
Assy Ice Maker(FZ) more than 3 times, the error will be
Error
displayed.

Damper heater housing removal, poor


Fridge Roome Damper contact and cable disconnection detected by
MOTOR DC-DAMPER
Heater Error the damper heater as open error, and defects
are displayed.

42
Water Tank heater housing removal, poor
Fridge Room Water contact and cable disconnection detected by
Water Tank Heater Open
Tank Heater Error the damper heater as open error, and defects
are displayed.

Display pc - Er in the panel with alarm :


Panel PBA Main PBA 1. Panel PBA
MICOM MAIN PANEL communication
Communication Error 2. Main PBA
error.

Main PBA - Inverter Display 44Er in the panel :


1. Inverter PBA
PBA Inverter MICOM Main MICOM
2. Main PBA
Communication Error communication error.

If temperature in the freezing compartment


Abnormal high
rises to abnormal level or the door is kept
temperature in freezing 1. Cooling Cycle Check
for an extended period of time, the display
compartment Blinking
of the freezing compartment blinks.

If temperature in the cold compartment rises


Abnormal high
to abnormal level or the door is kept for an
temperature in cold 1. Cooling Cycle Check
extended period of time, the display of the
compartment Blinking
cold compartment blinks.

43
Comp starting Failure Defect is displayed if the compressor startup
1. Inverter PBA
Error fails.

Comp Inveter PBA IPM Defect is displayed upon the compressor IPM
1. Inverter PBA
Fault Error fault error.

Compressor Abnormal Defect is displayed if the compressor


1. Inverter PBA
current Detection Error abnormal current is detected.

Compressor motor
Defect is displayed upon the compressor
Locked or Over RPM 1. Inverter PBA
motor constraint.
Error

Compressor under Defect is displayed upon the compressor low


1. Inverter PBA
voltage Error voltage error.

44
Comp over voltage Defect is displayed upon the compressor
1. Inverter PBA
Eroor overvoltage error.

45
Code Item Check Parts Trouble contents Image-1 Image-2
Left-Display-

Air sensor connector missing ; contact


Ambient-Sensor Error Ambient-Sensor failure, electric wire cut, short-circuit; open
air sensor itself failure; and so on

Left-Display-

Freezer sensor connector missing ; contact


Freezer Room Sensor
Freezer Room Sensor failed, electric wire cut, shortcircuit ; Freezer
Error
Room sensor itself failure

Left-Display-

Freezer evaporator defrosting sensor


Freezer-Defrost-Sensor connector missing; contact failed, electric
Freezer-DEF-Sensor
Error wire cut, shortcircuit ; sensor itself failure ;
and so on

Left-Display-

Freezer Fan motor operation failure; feedback


Freezer Room FAN Error Freezer Room FAN BLDC signal line contact failure, motors electric
wire missing; and so on.

Left-Display-

Condenser Fan motor operation failure;


Condenser-FAN Error Condenser-FAN BLDC feedback signal line contact failure, motors
electric wire missing; and so on.

46
Left-Display-

1. Freezer-DEF-Heater In the freezer room, if frost removal mode is


Freezer Defrosting Error 2. Freezer-Defrost Sensor finished due to limited time of 70 minutes.
3. Main PBA Error is displayed

Right-Display-
Display error : separation of sensor housing
part, contact error, disconnection, short
Ice Maker (Fridge) circuit.
ASSY Ice Maker (Fridge)
Sensor Error Display error of detecting temperature of
sensor : more than 149(+65C) or less than
-58(-50C)

Right-Display-

Compressor Error Inverter PBA When there is a Compressor restriction error

Right-Display-

Refrigerator sensor connector missing ;


Fridge Room Sensor
Fridge Room Sensor contact failure, electric wire cut, short-circuit
Error
; Refrigeratorsensor itself failure; and so on

Right-Display-

Damper Heater is sensed as open error due


Fridge Room Damper
MOTOR DC-DAMPER to Connector Slipped-Out or Open-Contact,
Heater Error
Wire Cut.

47
Right-Display-

Ice Maker(FZ) Function Ice-ejector and level failed three times or


Assy Ice Maker
Error more

48