You are on page 1of 55

ALCATEL

1660 SM

ALCATEL 1660SM
Sub--assemblies Description
Sub

T2-1
ALCATEL
1660 Subassemblies Description -Index 1660 SM

 1. Section I : ALCATEL 1660SM - Boards description

 2. Section II: Acronyms

T2-2
ALCATEL
1660 SM

Section I
ALCATEL 1660SM
Boards Description

T2-3
ALCATEL
1660 SM

Basic Area
Boards

T2-4
ALCATEL
1.1. P63E1 Port Card: Front View 1660 SM

T2-5
ALCATEL
1.1. P63E1 Port Card: 63x2Mb/s 1660 SM

 P63E1 interfaces 63 x 2Mbit/s signals to STM4-BPF signal (BPF=back panel format) with
AU4#1 of the STM-4* frame

T2-6
ALCATEL
1.1. P63E1N Port Card: Front View 1660 SM

T2-7
ALCATEL
1.1. Notes: 21 x 2 Mbit/s G.703/ISDN-PRA 1660 SM

 The 63 x 2 Mbit/s /G.703/ISDN-PRA port is similar to the basic 63 x 2 Mbit/s port, described in the
previous pages, with the difference that the present board implements also the NT functionality on ISDN
Primary Rate Access (PRA) and the "Retiming function" on the 2 Mbit/s interfaces.

 Retiming
 The Retiming function applies the Equipment Clock to the outgoing 2Mb/s signal that therefore
becomes synchronized with the SDH network synchronization reference .
 This feature is programmable via SW, in order to include or exclude the Retiming for each single port.
The same P63E1N unit can mix ports that apply or not the retiming.

 The ISDN-PRA (Integrated Services Digital Network - Primary Rate Access) is a facility to carry a
number of synchronous digital communication channels to the user over a 2048 kbit/s structured signal; the
ISDN- PRA structure is defined in recommendation ETS 300 233. The sample frames are reported in the next
pages.

 The 2048 kbit/s signals can be structured or non-structured: in this latter case, the PRA functionality
must be disabled from Craft-Terminal. The selection between structured/non-structured and basic-
frame/multiframe options is achieved by means of Craft-Terminal, for individual signals.
 It performs standard PRA functionality as well as some custom Leased Line functions (settable from C.T.).

T2-8
ALCATEL
1.2. P3E3/T3 Port Card: Front View 1660 SM

T2-9
ALCATEL
1.2. P3E3/T3 : 3x34Mb/s or 3x45Mb/s 1660 SM

Notes
 SDH functions are preformed by four Gate Array, one for each port and one that is common to
the three ports.

 34/45 Mbit/s interface: PPI functions are according to G.703 Rec; they are implemented in
the relevant Access Card.

 INPUT side and OUTPUT side


LPA: asynchronous mapping/demapping of 3x34 /45 Mbit/s into/from C-3
LPT : POH processing
STM-4 & timing G.A. provides to connect the three 34/45 Mbit/s interface to the
backpanel.

T2-10
ALCATEL
1.3. P4S1N / P4E4N Port Card: Front View 1660 SM

T2-11
ALCATEL
1.3. P4S1 Port Card: 4xSTM1 E/O 1660 SM

Notes
 P4S1 Port card processes up to four STM-1 streams. A max. of two electrical or optical
modules can be housed on the card to give physical access to the STM-1 signal. The remaining
two physical accesses are on the relevant Access Card .

 The main parts of the cards are:


Mother board, supporting the overall structure;
Cristallo ASIC
STM1 Modules
Timing, Control and Power Supply circuits
Details of internal structure of each block are shown in the next slide.

 SDH functions needed to process STM-1 signals are implemented by the Cristallo ASIC
mounted on the mother board. It interfaces the two MATRIX card via backpanel.

 Main connection toward the MATRIX is performed by three links at 622Mb/s:


 Link L toward LPC Matrix
 Link H and Link X toward HPC Matrix.

T2-12
ALCATEL
1.3. Notes: P4E4N Port Card 1660 SM

 The 4x140/STM1 switchable O/E port card is a bi- directional unit which interfaces up to four
plesiochronous 140 Mbit/s (E4) or Synchronous 155 Mbit/s (STM-1) with STM4-BPF
(BPF=backpanel format ).

 The choice between the two possible different interfaces is flexible and mixed configuration
are allowed.

 For each P4E4N port card there are four electrical (75 Ohm) or optical module(Short and Long
Haul) ; two of the four module are hosted directly on the port card , the other two are hosted
in the relevant access card (A2S1).

T2-13
ALCATEL
1.4. P4ES1 Port Card: Front View 1660 SM

T2-14
ALCATEL
1.4. P4ES1 Port Card: 4xSTM1 Interfaces 1660 SM

Notes
 P4ES1 Port Card supports 4xSTM1 streams and has the same structure as already described
for P4S1 Port Card in the previous slide 1.3.

 The only difference compared with P4S1 is in the access interfaces, that are all 4 in a dedicated
Access Card (A4ES1).

 This card, together with the relevant A4ES1 Access Card, allows to implement Electrical
STM1 ports with EPS, while P4S1 allows to implement only APS protection.

 Future releases will extend the use of this board to 140 E4 interfaces, with Sw switchable pre-
setting.

T2-15
ALCATEL
1.5. STM4 Interface: Front View 1660 SM

T2-16
ALCATEL
1.5. STM4 : S/L-4.x Port Card 1660 SM

Notes
 Main parts of STM4 Port Card are: Motherboard, Cristallo ASIC, STM4 Optical Module
(SPI) and Circuits for: Control, Timing and Power Supply.

 Functions performed by the CRISTALLO ASIC at Rx and Tx side are:


 TTF ( SPI, RST, MST, MSA)
 HOA (HPT, HPA): this block includes F2-F3 byte extraction/insertion for a DCC_P
channel frame .

 Connection with MATRIX is performed by 3 links at 622Mb/s: X, L and H Links. T1 clock


at 2 MHz is extracted and sent to the Matrix card.

 Different units are available with different connectors (FC/PC or SC/PC) and
different wave length (S-4.1, L-4.1, L-4.2 and L-4.2JE). JE type STM4 is available
in two options, with different max chromatic dispersion.

T2-17
ALCATEL
1.6. STM16 Interface: Front View 1660 SM

T2-18
ALCATEL
1.6. STM16 Interface 1660 SM

Notes
 Port identifier
 STM16 Port Card is identified by the name S / L-16.x where x=1 or 2.
 Different part number corresponds to different connector type, FC/PC or SC/PC or
SC/SPC.
 The units identified by JE (Joint engineering, 3 types available) have improved optical
characteristics, mainly for the dispersion values.
 The STM-16 with 192.3 to 195.7 label (also defined coloured), are used when
interfaced with WDM equipment. That number indicates the central frequency (in THz)
of the carrier optical signal, related to the wavelength : sixteen units are independently
associated with different wavelength.
 The WDM equipment can receive up to sixteen different wavelength signals from sixteen
different STM-16 optical ports.

T2-19
ALCATEL
1.6. STM16 Interface 1660 SM

Notes
 General Architecture
 SDH functions are implemented by four CRISTALLO ASICs ( ASIC#1 to ASIC#4)
mounted on the board. They interface the two MATRIX boards via backpanel.

 A dedicated ASIC performs Mux/Demux of 4xSTM4 streams and loopback functions.


This ASIC also interfaces the line side with one stream at 2488 Mbit/s.

 The following functions are performed by the 4 CRISTALLLO ASICs :


TTF (only the ASIC #1 )

HOA (all ASICs from 1 to 4)

LPOM /LSUT (all ASICs from 1 to 4).

HPOM /HSUT ( only ASIC.#1).

T2-20
ALCATEL
1.7. EQUICO: Front View 1660 SM

T2-21
ALCATEL
1.7. EQUICO Card 1660 SM

Notes
 The following main functions of EQUICO card are performed by Equipment
Controller (EC)
 local communication with Craft Terminal (F interface);

 communication with the OS through Q3 and DCC interface.

 communication with an external non-SDH equipment for Network Management


operations through Q2 Interface (Mediation Device Function);

 alarm processing and indications: remote alarms (RE) , alarms towards the rack lamps
(RA), housekeeping alarms (HK) and front cover LED;

 ISSB bus management: supporting communication between EC and SC function on the


MATRIX Card

T2-22
ALCATEL
1.8. MATRIXN Card: Front View 1660 SM

T2-23
ALCATEL
1.8. MATRIX Card 1660 SM

Notes

 MATRIX card performs different functions, with 1+1 EPS : Connections between ports;
Equipment Synchronization; Shelf Controller ; Performance Monitoring ; Power Supply;
Remote Inventory.
 Connections: Connections between MATRIX and ports

 Shelf controller functions: SW functions related to the control and management operation of the
boards (Management Bus; ISSB Intra Shelf Serial Bus; RIBUS) .

 Performance monitoring: Performance monitoring can be made at: Regeneration section; Multiplex
section; Multiplex section Adaptation; HSUT and LSUT; HPOM and LPOM; HPT and LPT.

T2-24
ALCATEL
1.8. MATRIX Card 1660 SM

Notes

 Within the MATRIX the following SDH functions are implemented to activate the
connections:
 MSP (Multiplex Section Protection)+ MS-SPRING

 AU4 squelching ( for MS-SPRING)

 SNCP: SNCP/I and SNCP/N

 HPC (High order Path Connection) (96x96


96x96 ports)
ports

 LPC (Low order Path Connection) (64x64


64x64 STM1 equivalent signals at VC-12 level).

 Equipment Synchronization: SETS function , with local oscillator at 10MHz, generating: T0


(at 622.08 MHz), CK38Mhz (derived from T0 and distributed to all the ports; MFSY (
Multiframe synchronism at 500 Hz distributed to all the ports);2 MHz clock T4 , accessible
from the SERVICE board.

T2-25
ALCATEL
1.9. CONGI Card: Front View 1660 SM

T2-26
ALCATEL
1.9. External Accesses: CONGI Card 1660 SM

FUNCTION FUNCTION
PIN IF INSERTED IN SLOT 10 IF INSERTED IN SLOT 12
1 GND GND
2 NURG:Not urgent alarm LOSQ2
PS 3 URG :Urgent alarm TANC: Loss of 3.3 V on one CONGI
4 TOR:OR battery TORC: Loss of 3.3 V on both CONGI
5 TAND:AND batteries IND: indeterminate alarm (not used)
15 8 6 INT:Internal alarm TUP: microprocessor fault
7 HK-OUT1:Output parallel contact 1 HK-OUT3:Output parallel contact 3
9 1 8 HK-OUT2:Output parallel contact 2 HK-OUT4:Output parallel contact 4
9 Not Used Not Used
Rack lamps 10 HK-IN12:Input parallel contact 12
HK-IN6:Input parallel contact 6
11 HK-IN5:Input parallel contact 5 HK-IN11:Input parallel contact 11
12 HK-IN4:Input parallel contact 4 HK-IN10:Input parallel contact 10
Q2 13 HK-IN3:Input parallel contact 3 HK-IN9:Input parallel contact 9
14 HK-IN2:Input parallel contact 2 HK-IN8:Input parallel contact 8
15 HK-IN1:Input parallel contact 1 HK-IN7:Input parallel contact 7

QB3 Housekeeping and remote alarm

T2-27
ALCATEL
1.9. CONGI Card 1660 SM

Notes
 The 1660SM equipment can house two CONGI cards, referred as CONGI A (slot 10) and
CONGI B (slot 12).
 They are not intended as main and spare : each card provides a set of functions . Both units are
necessary to provide the complete set.
 CONGI A can be used as stand alone but in this case only a subset of interfaces are available.

CONGI A and CONGI B interfaces :

CONGI A CONGI B
POWER POWER
Housekeeping & Remote Housekeeping & Remote
Alarms (a subset) Alarms ( a subset)
Rack lamps (R/M) Not used
QMD (Q2) Not used
Q3 10 base 2 Not used
Q3 10 base T Not used
INT led INT led

T2-28
ALCATEL
1.10. SERVICE Card: Front View 1660 SM

T2-29
ALCATEL
1.10. SERVICE Card 1660 SM

Notes
 The SERVICE card provides the following functions :
 AUX (auxiliary) channels management;
 Input/output clock management;
 EOW channels management;
 POWER SUPPLY for internal board use.

 AUX channels management:


four G.703 64 Kbit/s channels, ITU-T G.703 compliant
four V11 channels , every one composed by data input, data output and clock
four RS-232 channels
two 2 Mbit/s G.703 signals that can be used as auxiliary channels

 Input/Output clock management:


the unit can receive two 2 MHz or 2Mbit/s clock signals that could be used to synchronise the N.E.
(T3/T6)
the unit provides two 2 MHz or 2Mbit/s output clock signals (T4/T5) that can be used by another
N.E. for synchronization purpose.

T2-30
ALCATEL
1.10. SERVICE Card 1660 SM

Notes
 EOW management allows to implement three different types of connections:

between two stations (selective call)(number of the equipment)

among three stations (multi-selective call)

omnibus call (one station is connected with all the other )(00)

 To this purpose a telephone jack is present on the unit front panel.

 Two extension channels with different connectors (RJ45 and RJ11) are available to
establish a connection with an external telephone set.

 Moreover the channel on RJ11 can be used to establish a connection with an external
telephone network

T2-31
ALCATEL
1660 SM

Access Area:
Boards

T2-32
ALCATEL
1.11. A21E1(2 Mb/s coax): Front View 1660 SM

21 x 2 Mbit/s 75 ohm port.

T2-33
ALCATEL
1.11. A21E1 Access Card: 2 Mb/s coax 1660 SM

Notes
 The front panel of A21E1 gives the access for 21x2Mb/s with coax 1.0/2.3.

 The card includes the protection switches for N+1 EPS protection

T2-34
ALCATEL
1.11. A21E1(2 Mb/s balanced): Front View 1660 SM

21 x 2 Mbit/s 120 ohm prot. or 21 x 2 Mbit/s 120 ohm K20

T2-35
ALCATEL
1.11. A21E1 Access Card :2 Mb/s balanced 1660 SM

PIN SIGNAL PIN SIGNAL


1 GND 20 GND
2 GND 21 GND
19 3 GND 22 GND
4 Not Used 23 Not Used
5 Not Used 24 Output Ch. 7, side b
6 Output Ch. 7, side a 25 Input Ch. 7, side b
7 Input Ch. 7, side a 26 Output Ch. 6, side b
8 Output Ch. 6, side a 27 Input Ch. 6, side b
20 1 9 Input Ch. 6, side a 28 Output Ch. 5, side b
10 Output Ch. 5, side a 29 Input Ch. 5, side b
11 Input Ch. 5, side a 30 Output Ch. 4, side b
12 Output Ch. 4, side a 31 Input Ch. 4, side b
13 Input Ch. 4, side a 32 Output Ch. 3, side b
14 Output Ch. 3, side a 33 Input Ch. 3, side b
15 Input Ch. 3, side a 34 Output Ch. 2, side b
16 Output Ch. 2, side a 35 Input Ch. 2, side b
17 Input Ch. 2, side a 36
Output Ch. 1, side b
18 Output Ch. 1, side a 37 Input Ch. 1, side b
19 Input Ch. 1, side a - -

T2-36
ALCATEL
1.11. A21E1Access Card: 2 Mb/s balanced 1660 SM

Notes
 A21E1 has two options:
coax 75 ohm
symmetrical 120 ohm: in this cases two further options are possible:
Access card with protection switches for EPS
Access card with protection against overvoltage (ITU-K 20)

T2-37
ALCATEL
1.12. A3E3 Access Card: Front view 1660 SM

T2-38
ALCATEL
1.12. A3E3 Access Card: 3x34Mb/s Interfaces 1660 SM

Notes
 3 X 34 Mbit/s access card provides connections from back-panel to the external signals for
three PDH 75 ohmG.703 signals.

 INPUT side
 From the HDB3 signal, clock is recovered and data are retimed and sent to an HDB3
decoder. LOS alarm is generated if no signal is detected. In normal condition the
backplane provides to send the signal to the main card. .
 The access card manages the EPS protection of the 3x34/45 port card; two mux by means
of dedicated command (SEL) coming from the RIBUS I/F block, sends to spare card
Signal and LOS of actual or previous access card.

 OUTPUT side
 NRZ data and clock from the main and spare port card are received. In normal condition,
signal coming from the main port card is HDB3 encoded and sent to the line. When EPS is
active, the RIBUS I/F block send a command (SEL) to the mux; in this case the signal
coming from the spare card is selected and sent toward the encoder.

T2-39
ALCATEL
1.12. A3E3 Access Card: 3x34Mb/s Interfaces 1660 SM

Notes
 Loopback functions
 The access card provides line loopback (RLOP) and local loopback (LLOP).When RLOP
is active the input signal coming from the line is sent back to the output signal.When
LLOP is active, the signal coming from the encoder is sent to the decoder

 Control section
 The commands to drive the MUXs involved in EPS protection (SEL) and the loopback
functions (CLOP) are generated by the RIBUS I/F block that performs also remote
inventory and card status operations (FAIL).

T2-40
ALCATEL
1.13. A3T3 Access Card: Front View 1660 SM

3 x 45 Mbit/s 75 ohm

T2-41
ALCATEL
1.13. A3T3 Access Card : 34 Mb/s 1660 SM

Notes
 A3E3 and A3T3 have the same front panel.

 They are both connected to a P3E3/T3 Port Card.

T2-42
ALCATEL
1.14. A2S1 Access Card: Front View 1660 SM

T2-43
ALCATEL
1.14. A2S1 Access Card: 2xSTM1 E/O 1660 SM

Notes
 A2S1 Access Card can house two independent modules that can be both electrical , both
optical or a mix of the two.

 The Access Card houses also the RIBUS I/F block and the Remote Inventory.

T2-44
ALCATEL
1.15. A4ES1 Access Card : Front View 1660 SM

T2-45
ALCATEL
1.15. A4ES1 Access Card: 4xSTM1/El. 1660 SM

Notes
 The A4ES1 access card is placed in the access area and allows the connection to the line
coaxial cable for the High Speed port cards 4x STM1 or 4x140 Mb/s.
 A4ES1 gives access to 4 STM1/El coming from P4ES1 Port Card.

 INPUT side
 CMI coming from the coaxial cable, is equalised, decoded into NRZ code and forwarded to main
electrical port card.
 SWITCH criteria coming from the RIBUS I/F block can select the MUX in order to send toward the
Spare card the local stream.
 LOS alarm, if present, is sent to the main board. The same alarm can also be sent ,through a MUX,
toward the spare card if the SWITCH command is active.

 OUTPUT side
 At output side, the signal coming from the Main card, is coded into CMI code and then sent toward the
coaxial cable.
 When EPS is active, the RIBUS I/F block send a command (SWITCH) to the MUX; in this case the
signal coming from the Spare card is selected and sent toward the encoder NRZ/CMI.

T2-46
ALCATEL
1.15. A4ES1 Access Card: 4xSTM1/El. 1660 SM

Notes
 Control section
 INT LOOP1 ... INT LOOP4: Internal Loop commands for channels from 1 to 4
 LINE LOOP1 ... LINE LOOP4: Line Loop commands for channels from 1 to 4
 FSEL for frequency selection 155/140 Mbit/s
 SWITCH allows EPS facility
 On the front cover plate a red/green led is available for card fail alarm indication.

T2-47
ALCATEL
1.16. HPROT Front View 1660 SM

T2-48
ALCATEL
1.16. HPROT Protection Access Card 1660 SM

Notes
 The HPROT access card is used to implement EPS protection for High Speed ports.
ports It
implements the connection between the Access Cards and Spare HS Port if protection is
request. It receives the signals coming from the access card via back panel .

 Control section
 The RIBUS I/F block is present to read/write inventory data as code, series number,
construction data implemented on the RI.
 On the front cover plate a red/green led is available for card fail alarm indication.

T2-49
ALCATEL
1.17. STM1 Modules 1660 SM

STM1 Optical

INPUT INPUT
OUTPUT OUTPUT SPI
sink
155Mb/s
+
Clock
SPI
source

ALS restart key ALS restart key

SC/PC FC/PC

STM1 Electrical

SPI
INPUT sink
155Mb/s
STM1 +
G.703 Clock

SPI
source
OUTPUT

T2-50
ALCATEL
1.17. Notes:STM1 Modules 1660 SM

 Each STM1 module performs the following functions, corresponding to SPI block:

 The SPI sink function is implemented on Optical (or Electrical) Line-Modules. It


interfaces the line signal and recovers the STM1 data and clock. In the case of the Optical
Module it performs the optical to electrical conversion and detects also the LOS alarm.
(Rx side)

 The SPI source function is implemented on Optical (or Electrical) Line-Modules. It


receives (from GA) the STM1 data and clock and build-up the STM1 line signal. In the
case of the Optical Module it detects also the Laser-Degrade, Laser-fail alarms and can
receive the Laser-Shut-Down command (for ALS). (Tx side)

T2-51
ALCATEL
1660 SM

Section II
ALCATEL 1660SM
- Acronyms -

T2-52
ALCATEL
3. Acronyms/1 1660 SM

ABIL Enabling CPI Incoming parallel contacts


ABN Abnormal CPO Outgoing parallel contacts
ADM Add/Drop Multiplexer CPU Central Processing Unit (referred to Controller equipment unit
AIS Alarm indication Signal or Microprocessor)
ALS Automatic Laser Shutdown C12/C3/C4 1st, 3rd and 4th level container
APD Avalanche Photodiode DC Direct Current
APS Automatic Protection Switching DCC Data Communication Channel
AND Alarm on both station batteries DCE Data Circuit Terminating Equipment
ANSI American National Standards International DPLL Digital Phase Locked Loop
ASIC Application Specific Integrated Circuit DTE Data Terminal Equipment
ATM Asynchronous Transfer Module EBU European Broadcasting Union
ATTD Attended (alarm storing) EC Equipment Controller
AU Administrative Unit ECC Embedded Control Channel
AUG Administrative Unit Group ECT Equipment Craft Terminal
AUOH AU Pointer EMC Electromagnetic compatibility
AUX Auxiliary EMI Electromagnetic interference
AU4 Administrative unit level 4 EOW Engineering Order Wire
BATT Battery EPS Equipment Protection Switching
BER Bit Error Rate ESD Electrostatic discharges
BIP Bit Interleaved Parity ETSI European Telecommunication Standards Institute
BNC Bayonet Not Coupling E2PROM Electrically erasable programmable read only memory
C Storing command F Interface F (for Craft Terminal) or Fuse
CE European Conformity FEBE Far End Block Error
CO Central Office FEPROM Flesh Electrically erasable programmable read only memory
CPE Customer premises equipment FERF Far End Receive Failure
CT Craft Terminal FPGA Field Programmable Gate Array
CMI Code Mark Inversion GA Gate Array
COAX Coaxial GND Ground

T2-53
ALCATEL
3. Acronyms/2 1660 SM

HDB3 High Density Bipolar Code LPC Lower order path connection
HIGHREFL High Optical reflections LPOM Lower Order Path Monitoring
HOA High Order Adaptation LPT Lower order path termination or Loopback equipment side
HOI High Order Interface (local)
HPC High order Path Connection LSUT Lower order Supervisory Unequipped Termination
HPT Higher Order Path Termination M Tagblock or Alarm storing
HPOM High order Path Overhead Monitoring MCF Message Communication Function
HSUT High order Supervisory Unequipped Termination MLM Multi Longitudinal mode
HW Hardware MSA Multiplex section adaptation
ICS Item Change Status MSOH Multiplex Section Overhead
ID Identification signals MSP Multiplex section protection
IEC International Electrotechnical Committee MST Multiplex section termination
IEEE Institute of Electrical and Electronic Engineering NRZ No return to zero
IN Input NURG Not urgent alarm
IND Indicative alarm OHBUS Dedicated housekeeping stream
INT Internal Local Alarms OOF Out Of Frame
IP Internet Protocol OR Logic sum/Loss of only one station battery
ISO International Organism for standardization OS Operating system
ITUT (*) International Telecomm. UnionTelecomm.Sector OUT Output
JE1 Joint Engineering P/S Parallel/Serial converter
LAN Local Area Network PC Personal Computer
LDSSHUT Command for ALS PDH Plesiochronous Digital Hierarchy
LED Light emitting diode PFAIL Power supply failure
LOF Loss of alignment PI Physical interface
LOI Low Order Interface PJE Pointer Justification Event
LOM Loss Of Multiframe PPI Plesiochronous Physical interface
LOP Loss Of Pointer POH Path Overhead
LOS Loss of signal PMMF Physical Machine Management Function
LPA Lower order path adaptation PPS Path Protection Switching

T2-54
ALCATEL
3. Acronyms/3 1660 SM

PRBS Pseudo Random Binary Signal SNCP/N Subnetwork Connection Protection/ Not Intrusive
PWALM supply alarm SOH Section Overhead
PWANDOR ANDOR/3 failure S/P Serial/Parallel Converter
Q2/QB2 TMN Interface with B2 protocol. SPI Synchronous Physical Interface
Q3/QB3 TMN Interface with B3 protocol. SSF Server Signal Fail
R Reset command /General alarm SQ Squelch
RAI Remote Alarm Indication STM0/STM1 Synchronous Transport Module, levels 0 etc.
RECC Recommendation SW Software
RAM Random Access Memory TANC Remote alarm due to failure of all power supply units
RDI Remote Defect Indication TD Layout drawing
REI Remote Error Indication TIM Trace Identifier Mismatch
RCK Received clock TMN Telecommunication Management Network
REF Reference TOR Remote alarm indicating loss of one of the station batteries
REL Release TORC Remote alarm due to a faulty/missing power supply unit
RIBUS Remote Inventory BUS TSD Trail Signal Degrade
RMS Root Mean Square TSF Trail Signal Fail
RNURG Not urgent Alarm. Lights up the relative rack LED TTF Transport Terminal Function
RSOH Regenerator Section Overhead TUG2/3 Tributary unit group, level 2,3
RST Regenerator Section Termination TUOH Tributary Unit Overhead
RURG Urgent Alarm. Lights up the relative rack red LED TUP/UP Equipment Controller remote alarm
Rx Reception TU12/TU3 Tributary unit level 12, 3
SC Shelf Controller TX Transmission
SDH Synchronous Digital Hierarchy URG Urgent
SETG Synchronous Equipment Timing Generation function VCXO/VCO Voltage controlled oscillator
SLM Single Longitudinal Mode VC12/VC3/VC4 Virtual Container, levels 12,3,4
SM Single Mode/Synchronous Mux VMMF Virtual Machine Management Function
SNCP/I Subnetwork Connection Protection Inherent WAN Wide Access Network

T2-55