You are on page 1of 14

12/22/2016 PotentialUserControlFeatureParameterDescription

WCDMARAN
PotentialUserControlFeatureParameterDescription
Issue 01

Date 20150325

HUAWEITECHNOLOGIESCO.,LTD.

CopyrightHuaweiTechnologiesCo.,Ltd.2015.Allrightsreserved.
NopartofthisdocumentmaybereproducedortransmittedinanyformorbyanymeanswithoutpriorwrittenconsentofHuaweiTechnologiesCo.,Ltd.
TrademarksandPermissions
andotherHuaweitrademarksaretrademarksofHuaweiTechnologiesCo.,Ltd.
Allothertrademarksandtradenamesmentionedinthisdocumentarethepropertyoftheirrespectiveholders.
Notice
Thepurchasedproducts,servicesandfeaturesarestipulatedbythecontractmadebetweenHuaweiandthecustomer.Allorpartoftheproducts,servicesandfeaturesdescribedinthisdocumentmaynotbewithinthepurchasescopeortheusagescope.Unlessotherwise
specifiedinthecontract,allstatements,information,andrecommendationsinthisdocumentareprovided"ASIS"withoutwarranties,guaranteesorrepresentationsofanykind,eitherexpressorimplied.

http://127.0.0.1:52199/hedex/hdx.do?lib=GEE0116P&v=11&id=ENUS_BOOKMAP_0001792561&tocURL=resources%252fen%252dus%255fbookmap%255f0001792561%252ehtml&p=t&fe=1&ui=3&keyword=puc 1/14
12/22/2016 PotentialUserControlFeatureParameterDescription
Theinformationinthisdocumentissubjecttochangewithoutnotice.Everyefforthasbeenmadeinthepreparationofthisdocumenttoensureaccuracyofthecontents,butallstatements,information,andrecommendationsinthisdocumentdonotconstituteawarrantyofany
kind,expressorimplied.

HuaweiTechnologiesCo.,Ltd.
Address: HuaweiIndustrialBaseBantian,LonggangShenzhen518129People'sRepublicofChina

Website: http://www.huawei.com

Email: support@huawei.com

Contents
1 About This Document
1.1Scope
1.2IntendedAudience
1.3ChangeHistory
1.4DifferencesBetweenBaseStationTypes
2 Overview
2.1Definition
2.2Benefits
3 Technical Description
4 Engineering Guidelines
4.1Requirements
4.2DataPreparation
4.3Activation
4.3.1UsingMMLCommands
4.3.2MMLCommandExamples
4.3.3UsingtheCME
4.4ActivationObservation
4.5Deactivation
4.5.1UsingMMLCommands
4.5.2MMLCommandExamples
4.5.3UsingtheCME
5 Parameters
6 Counters
7 Glossary
8 Reference Documents

1AboutThisDocument

1.1Scope
ThisdocumentdescribesWRFD020105PotentialUserControl,includingitstechnicalprinciples,relatedfeatures,networkimpact,andengineeringguidelines.

http://127.0.0.1:52199/hedex/hdx.do?lib=GEE0116P&v=11&id=ENUS_BOOKMAP_0001792561&tocURL=resources%252fen%252dus%255fbookmap%255f0001792561%252ehtml&p=t&fe=1&ui=3&keyword=puc 2/14
12/22/2016 PotentialUserControlFeatureParameterDescription
ThisdocumentappliestothefollowingNEtypes.

NEType NEModel

RNC BSC6900andBSC6910

NodeB Macro 3900seriesmacrobasestations:BTS3900,BTS3900A,BTS3900L,BTS3900AL,DBS3900,BTS3900C

Micro BTS3902E

LampSite DBS3900LampSite

1.2IntendedAudience
Thisdocumentisintendedforpersonnelwho:

Needtounderstandthefeaturesdescribedherein
WorkwithHuaweiproducts

1.3ChangeHistory
Thissectionprovidesinformationaboutthechangesindifferentdocumentversions.Therearetwotypesofchanges,whicharedefinedasfollows:

Featurechange
Changesinfeaturesandparametersofaspecifiedversionaswellastheaffectedentities
Editorialchange
Changesinwordingoradditionofinformationandanyrelatedparametersaffectedbyeditorialchanges.Editorialchangedoesnotspecifytheaffectedentities.

RAN17.101(20150325)

Thisissuedoesnotincludeanychanges.

RAN17.1DraftA(20150115)

ComparedwithIssue01(20130428)ofRAN15.0,DraftA(20150115)ofRAN17.1includesthefollowingchanges.

ChangeType ChangeDescription ParameterChange

Featurechange AddedimpactsofWRFD171214InterBandLoadBalancingonthisfeature.Fordetails,see3TechnicalDescription. None

Editorialchange None None

1.4DifferencesBetweenBaseStationTypes
FeatureSupportbyMacro,Micro,andLampSiteBaseStations

FeatureID Description SupportedbyBaseStationController SupportedbyMacroBaseStation SupportedbyMicroBaseStation SupportedbyLampSiteBase


Station
BSC6900 BSC6910

WRFD020105 PotentialUserControl Yes Yes Yes Yes Yes

NOTE:
N/AindicatesthatanNEisnotinvolved,thatis,afeaturedoesnotrequirethesupportoftheNE.

TheBTS3902EdoesnotsupportanynewandenhancedfeaturesorfunctionsinRAN17.1.Fordetails,see1.3ChangeHistory.

2Overview
2.1Definition
Thefunctionofpotentialusercontrol(PUC)istobalancetrafficloadamongcellsondifferentfrequenciesbycontrollingparametersofthesysteminformationbroadcast.TheRNCusesPUCtomodifycellselectionandreselectionparameters.Itthenbroadcasts
themodificationsthroughsysteminformation,allowingUEstoberedirectedtocellswithlightload.UEscanbeinidlemode,CELL_FACHstate,CELL_PCHstate,orURA_PCHstate.

2.2Benefits
ThisfeatureallowstheUEtochooseacelltocamponbasedonthecellload.

http://127.0.0.1:52199/hedex/hdx.do?lib=GEE0116P&v=11&id=ENUS_BOOKMAP_0001792561&tocURL=resources%252fen%252dus%255fbookmap%255f0001792561%252ehtml&p=t&fe=1&ui=3&keyword=puc 3/14
12/22/2016 PotentialUserControlFeatureParameterDescription
3TechnicalDescription
ThePUCfunctioncontrolscellselectionandreselectionbyaUEthatisinidlemode,intheCELL_FACHstate,CELL_PCHstate,orURA_PCHstate,andpreventstheUEfromcampingonaheavilyloadedcell.
ThePUCisonlyvalidforinterfrequencycells,andtakeseffectinthedownlinkonly.
Figure31showsthePUCprocedure.
Figure31PUCprocedure

ThePUCfunctionisenabledonlywhenPUCoftheNBMLdcAlgoSwitch(BSC6900,BSC6910)parameterissetto1.
IfacelldoesnotsupportDCHSDPA,theRNCperiodicallymonitorsthedownlinkloadofthecell.

Ifthecellloadisgreaterthantheupperthreshold(SpucHeavy(BSC6900,BSC6910)plustheloadleveldivisionhysteresisSpucHyst(BSC6900,BSC6910)),thecellloadisheavy.
IfthecellloadislowerthanthelowerthresholdSpucLight(BSC6900,BSC6910)minusSpucHyst(BSC6900,BSC6910),thecellloadislight.

IfthecellsinagroupsupportDCHSDPA,theRNCconcurrentlymonitorstheloadstateofeachcellandtheloadstateofthecellgroup.

ThecheckingofloadstateofasinglecellisthesameasthatofacellnotsupportingDCHSDPA.
Thecheckingofloadstateofacellgroupisasfollows:
IftheloadofthetwocellsisgreaterthantheirupperthresholdsSpucHeavy(BSC6900,BSC6910)plustheirloadleveldivisionhysteresisSpucHyst(BSC6900,BSC6910),theloadofthecellgroupisheavy.
IftheloadofthetwocellsislowerthantheirlowerthresholdsSpucHeavy(BSC6900,BSC6910)minustheirloadleveldivisionhysteresisSpucHyst(BSC6900,BSC6910),theloadofthecellgroupislight.

TheloadstateofacellsupportingDCHSDPAisdeterminedbasedonthefollowingtable.

LoadofaSingleCell LoadofaCellGroup LoadofaCellSupportingDCHSDPA

Heavy Heavy,normal,orlight Heavy

Heavy,normal,orlight Heavy Heavy

Normal Normalorlight Normal

Normalorlight Normal Normal

Light Light Light

Theloadstateofacellcanbeheavy,normal,orlight,asshowninFigure32.

http://127.0.0.1:52199/hedex/hdx.do?lib=GEE0116P&v=11&id=ENUS_BOOKMAP_0001792561&tocURL=resources%252fen%252dus%255fbookmap%255f0001792561%252ehtml&p=t&fe=1&ui=3&keyword=puc 4/14
12/22/2016 PotentialUserControlFeatureParameterDescription
Figure32Cellloadstates

Dependingonthecellload,thePUCworksasfollows:

Ifthecellloadisheavy,thePUCmodifiescellselectionandreselectionparametersandbroadcaststhemthroughsysteminformation.Inthisway,thePUCdirectsUEstolightlyloadedneighboringcells.
Ifthecellloadisnormal,thePUCusesthecellselectionandreselectionparametersconfiguredontheRNCLMT.
Ifthecellloadislight,thePUCmodifiescellselectionandreselectionparametersandbroadcaststhemthroughsysteminformation.Inthisway,thePUCdirectsUEstothiscell.
ThevariablesrelatedtocellselectionandreselectionareQoffset1(s,n)(loadleveloffset1),Qoffset2(s,n)(loadleveloffset2),andSintersearch(startthresholdforinterfrequencycellreselection).ThefollowingtabledescribesPUCrelatedvariables
andtheirimpactsonUEs.
Table31PUCrelatedvariablesandtheirimpactsonUEs

Item Description

Implementation TheNodeBperiodicallyreportsthetransmitpowerofthecell,andthePUCperiodicallytriggersthefollowingactivities:
AssessingthecellloadlevelbasedonthenonHSPApowerandHSDSCHGBP
SettingSintersearch,Qoffset1(s,n),andQoffset2(s,n)basedonthecellloadlevel
UpdatingtheparametersinsysteminformationSIB3andSIB11

Adjustment Basedonthecharacteristicsofinterfrequencycellselectionandreselection,theUEmakescorrespondingadjustments:
Sintersearch:
Whenthisvalueisincreasedbytheservingcell,theUEstartsinterfrequencycellreselectionaheadofschedule.
Whenthisvalueisdecreasedbytheservingcell,theUEdelaysinterfrequencycellreselection.
Qoffset1(s,n):appliestoR(reselection)rulewithCPICHRSCP.
Whenthisvalueisincreasedbytheservingcell,theUEhasalowerprobabilityofselectinganeighboringcell.
Whenthisvalueisdecreasedbytheservingcell,theUEhasahigherprobabilityofselectinganeighboringcell.
Qoffset2(s,n):appliestoR(reselection)rulewithCPICHEc/Io.
Whenthisvalueisincreasedbytheservingcell,theUEhasalowerprobabilityofselectinganeighboringcell.
Whenthisvalueisdecreasedbytheservingcell,theUEhasahigherprobabilityofselectinganeighboringcell.

ThecellreselectionparameterSintersearchisadjustedbasedontheloadstatusoftheservingcell.ChangestotheparameterSintersearcharemadeaslistedinTable32.
Table32ChangesmadetoSintersearchaccordingtotheloadstate

LoadStateoftheServingCell Sintersearch ChangetoSintersearch

Light S'intersearch=Sintersearch+OffSinterLight(BSC6900,BSC6910) Decrease

Normal S'intersearch=Sintersearch Remain

Heavy S'intersearch=Sintersearch+OffSinterHeavy(BSC6900,BSC6910) Increase

Remain:indicatesthattheparametervalueremainsunchanged.
Increase:indicatesthattheparametervalueincreases.
Decrease:indicatesthattheparametervaluedecreases.

TheconfigurationsofQoffset1andQoffset2arerelatedtotheloadoftheservingcellandtheloadoftheneighboringcells.ChangestoQoffset1andQoffset2aremadeaslistedinTable33.

http://127.0.0.1:52199/hedex/hdx.do?lib=GEE0116P&v=11&id=ENUS_BOOKMAP_0001792561&tocURL=resources%252fen%252dus%255fbookmap%255f0001792561%252ehtml&p=t&fe=1&ui=3&keyword=puc 5/14
12/22/2016 PotentialUserControlFeatureParameterDescription
Table33ChangesmadetoQoffset1andQoffset2accordingtotheloadstate

LoadStateoftheNeighboringCells LoadStateoftheServingCell Q'offset1 ChangetoQ'offset1 Q'offset2 ChangetoQ'offset2

Light Light Q'offset1=Qoffset1 Remain Q'offset2=Qoffset2 Remain

Light Normal Q'offset1=Qoffset1 Remain Q'offset2=Qoffset2 Remain

Light Heavy Q'offset1=Qoffset1+ Decrease Q'offset2=Qoffset2+ Decrease


OffQoffset1Light(BSC6900,BSC6910) OffQoffset2Light(BSC6900,BSC6910)

Normal Light Q'offset1=Qoffset1 Remain Q'offset2=Qoffset2 Remain

Normal Normal Q'offset1=Qoffset1 Remain Q'offset2=Qoffset2 Remain

Normal Heavy Q'offset1=Qoffset1+ Decrease Q'offset2=Qoffset2+ Decrease


OffQoffset1Light(BSC6900,BSC6910) OffQoffset2Light(BSC6900,BSC6910)

Heavy Light Q'offset1=Qoffset1+ Increase Q'offset2=Qoffset2+ Increase


OffQoffset1Heavy(BSC6900,BSC6910) OffQoffset2Heavy(BSC6900,BSC6910)

Heavy Normal Q'offset1=Qoffset1+ Increase Q'offset2=Qoffset2+ Increase


OffQoffset1Heavy(BSC6900,BSC6910) OffQoffset2Heavy(BSC6900,BSC6910)

Heavy Heavy Q'offset1=Qoffset1 Remain Q'offset2=Qoffset2 Remain

NOTE:
Changestotheprecedingparametersarethosecomparedwiththeirdefaultvalues.
WhenWRFD020105PotentialUserControlandWRFD171214InterBandLoadBalancingarebothenabled,parameteradjustmentsrelatedtoWRFD020105PotentialUserControlbecomeinvalidforcellselectionandreselectionamonghighandlowbands,
andcellselectionparametersareadjustedbasedonWRFD171214InterBandLoadBalancing.
Highbandsrefertothosehigherthan1200MHz,andlowbandsrefertothoselowerthan1200MHz.

4EngineeringGuidelines

4.1Requirements
License

Thisfeatureisnotunderlicensecontrol.

4.2DataPreparation
None

4.3Activation

4.3.1UsingMMLCommands
1.RuntheRNCMMLcommandMODUCELLALGOSWITCHtoselectPUC(PotentialUserControlAlgorithm)fromtheSwitchforCellLoadControldropdownlisttoenablethecellorientedPUCalgorithm.
2.RuntheRNCMMLcommandSETULDCPERIODtospecifytheperiodofpotentialusercontrol.Inthisstep,setPUCperiodtimerlengthtoanappropriatevalue.
3.RuntheRNCMMLcommandADDUCELLPUCtosetthecellorientedPUCalgorithmparameters.

4.3.2MMLCommandExamples
//ActivatingPotentialUserControl
MODUCELLALGOSWITCH:CellId=111,NBMLdcAlgoSwitch=PUC1;
SETULDCPERIOD:PucPeriodTimerLen=1800;
ADDUCELLPUC:CELLID=1,SPUCLIGHT=45,SPUCHEAVY=70,SPUCHYST=5,OFFSINTERLIGHT=2,OFFSINTERHEAVY=2,OFFQOFFSET1LIGHT=4,OFFQOFFSET2LIGHT=4,OFFQOFFSET1HEAVY=4,OFFQOFFSET2HEAVY=4;

4.3.3UsingtheCME

NOTE:

WhenconfiguringthefeatureontheCME,performasingleconfigurationfirst,andthenperformabatchmodificationifrequired.
Configuretheparametersofasingleobjectbeforeabatchmodification.Performabatchmodificationbeforeloggingoutoftheparametersettinginterface.

http://127.0.0.1:52199/hedex/hdx.do?lib=GEE0116P&v=11&id=ENUS_BOOKMAP_0001792561&tocURL=resources%252fen%252dus%255fbookmap%255f0001792561%252ehtml&p=t&fe=1&ui=3&keyword=puc 6/14
12/22/2016 PotentialUserControlFeatureParameterDescription
1.Configureasingleobject(suchasacell)ontheCME.
SetparametersontheCMEaccordingtotheoperationsequencedescribedinTable41.ForinstructionsonhowtoperformtheCMEsingleconfiguration,seeCMESingleConfigurationOperationGuide.
2.(Optional)ModifyobjectsinbatchesontheCME.(CMEbatchmodificationcenter)

Tomodifyobjectsinbatches,click ontheCMEtostartthebatchmodificationwizard.ForinstructionsonhowtoperformabatchmodificationthroughtheCMEbatchmodificationcenter,pressF1onthewizardinterfacetoobtainonlinehelp.

Table41ConfiguringparametersontheCME

SN MO NE ParameterName ParameterID ConfigurableinCMEBatch


ModificationCenter

1 UCELLALGOSWITCH RNC SwitchforCellLoadControl NBMLdcAlgoSwitch(BSC6900,BSC6910) Yes


SelectthePUCintheparameter.

2 ULDCPERIOD RNC PUCperiodtimerlength PucPeriodTimerLen(BSC6900,BSC6910) Yes

3 UCELLPUC RNC Qoffset1offset2 OffQoffset1Heavy(BSC6900,BSC6910) Yes

Qoffset1offset1 OffQoffset1Light(BSC6900,BSC6910) Yes

Qoffset2offset2 OffQoffset2Heavy(BSC6900,BSC6910) Yes

Qoffset2offset1 OffQoffset2Light(BSC6900,BSC6910) Yes

Sintersearchoffset2 OffSinterHeavy(BSC6900,BSC6910) Yes

Sintersearchoffset1 OffSinterLight(BSC6900,BSC6910) Yes

Loadleveldivisionthreshold1 SpucHeavy(BSC6900,BSC6910) Yes

Loadleveldivisionhysteresis SpucHyst(BSC6900,BSC6910) Yes

Loadleveldivisionthreshold2 SpucLight(BSC6900,BSC6910) Yes

4.4ActivationObservation
1.Configuretwocells,CELL_A11andCELL_A12asinterfrequencyneighboringcellsontheNodeB.
2.RuntheRNCMMLcommandMODUCELLPUCtochangethepotentialusercontrolthresholdforCELL_A11.
3.RuntheNodeBMMLcommandSTRDLSIMtosimulateasituationinwhichthecellhasahighload.
ThefollowingmessagescanbetracedontheIubinterface:theNBAP_SYS_INFO_UPDATE_REQmessagefromtheRNCtotheNodeB,andtheNBAP_SYS_INFO_UPDATE_RSPmessagefromtheNodeBtotheRNC.
TheupdatedsysteminformationcanbetracedontheUuinterface.ThevalueoftheSintersearchsignalingelement(IE)oftheSIB3ofCELL_A11increases,andthevaluesoftheQoffset1s,nandQoffset2s,nIEsoftheSIB11ofCELL_A11decrease.
4.RuntheRNCMMLcommandMODUCELLPUCtochangethepotentialusercontrolthresholdforCELL_A12.
5.RuntheNodeBMMLcommandSTRDLSIMtosimulateasituationinwhichCELL_A12hasahighdownlinkload.

ThefollowingmessagescanbetracedontheIubinterface:theNBAP_SYS_INFO_UPDATE_REQmessagefromtheRNCtotheNodeB,andtheNBAP_SYS_INFO_UPDATE_RSPresponsemessagefromtheNodeBtotheRNC.
TheupdatedsysteminformationcanbetracedontheUuinterface.ThevalueoftheSintersearchIEoftheSIB3ofCELL_A11decreases,andthevaluesoftheQoffset1s,nandQoffset2s,nIEsoftheSIB11ofCELL_A11increase.

4.5Deactivation

4.5.1UsingMMLCommands
RuntheRNCMMLcommandMODUCELLALGOSWITCH.Inthisstep,clearPUC(PotentialUserControlAlgorithm)undertheCellLDCalgorithmswitchparameter.

4.5.2MMLCommandExamples
//DeactivatingPotentialUserControl
MODUCELLALGOSWITCH:CellId=111,NBMLdcAlgoSwitch=PUC0;

4.5.3UsingtheCME

NOTE:

WhenconfiguringthefeatureontheCME,performasingleconfigurationfirst,andthenperformabatchmodificationifrequired.
Configuretheparametersofasingleobjectbeforeabatchmodification.Performabatchmodificationbeforeloggingoutoftheparametersettinginterface.

http://127.0.0.1:52199/hedex/hdx.do?lib=GEE0116P&v=11&id=ENUS_BOOKMAP_0001792561&tocURL=resources%252fen%252dus%255fbookmap%255f0001792561%252ehtml&p=t&fe=1&ui=3&keyword=puc 7/14
12/22/2016 PotentialUserControlFeatureParameterDescription
1.Configureasingleobject(suchasacell)ontheCME.
SetparametersontheCMEaccordingtotheoperationsequencedescribedinTable42.ForinstructionsonhowtoperformtheCMEsingleconfiguration,seeCMESingleConfigurationOperationGuide.
2.(Optional)ModifyobjectsinbatchesontheCME.(CMEbatchmodificationcenter)

Tomodifyobjectsinbatches,click ontheCMEtostartthebatchmodificationwizard.ForinstructionsonhowtoperformabatchmodificationthroughtheCMEbatchmodificationcenter,pressF1onthewizardinterfacetoobtainonlinehelp.

Table42ConfiguringparametersontheCME

SN MO NE ParameterName ParameterID ConfigurableinCMEBatch


ModificationCenter

1 UCELLALGOSWITCH RNC SwitchforCellLoadControl NBMLdcAlgoSwitch(BSC6900,BSC6910) Yes


DeselectthePUCintheparameter.

5Parameters
Table51Parameters

ParameterID NE MMLCommand Feature FeatureName Description


ID

NBMLdcAlgoSwitch BSC6900 ADD WRFD CampingStrategySwitchfor Meaning:


UCELLALGOSWITCH 151203 MassEvent Whethertoenablethealgorithmsrelatedtocellloadcontrol.Selectingaswitchenablesthecorrespondingalgorithmandclearingaswitchdisablesthecorrespondingalgorit
MOD WRFD LoadReshuffling 1.INTRA_FREQUENCY_LDB:Whethertoenablethecellbreathingalgorithm.ThisalgorithmadjustsPCPICHtransmitpowerofacellbasedonthedownlinkTCPloadto
UCELLALGOSWITCH 020106 SelfOptimizationUnder 2.PUC:WhethertoenablethePotentialUserControl(PUC)algorithm.ThisalgorithmadjustscellselectionandreselectionparametersbasedonthecellloadtoenableUE
WRFD UplinkInterference 3.UL_UU_LDR:Whethertoenabletheuplinkloadreshuffling(LDR)algorithm.Whentheuplinkloadisheavyinacell,thisalgorithmalleviatestheuplinkloadbyusingload
171213 RIMBasedUMTSTargetCell 4.DL_UU_LDR:WhethertoenablethedownlinkLDRalgorithm.Whenthedownlinkloadisheavyinacell,thisalgorithmalleviatesthedownlinkloadbyusingloadbasedi
WRFD SelectionforLTE
5.UL_UU_OLC:Whethertoenabletheuplinkoverloadcontrol(OLC)algorithm.Whentheuplinkpowerisoverloadedinacell,thisalgorithmalleviatestheuplinkloadbyus
150231 CoverageBasedPS
6.DL_UU_OLC:WhethertoenablethedownlinkOLCalgorithm.Whenthedownlinkpowerisoverloadedinacell,thisalgorithmalleviatesthedownlinkloadbyusingquick
WRFD RedirectionfromUMTSto
150219 LTE 7.OLC_EVENTMEAS:WhethertoenableOLCeventmeasurement.
WRFD LoadBasedPSRedirection 8.CELL_CODE_LDR:Whethertoenablecellcodereshufflingalgorithm.Intheeventofcoderesourceoveruse,thisalgorithmalleviatesthecoderesourceoverusebyusing
150216 fromUMTStoLTE 9.CELL_CREDIT_LDR:Whethertoenablethecellcreditreshufflingalgorithm.Intheeventofcellcreditoveruse,thisalgorithmalleviatesthecreditoverusebyusingloadb
WRFD LoadBasedPSHandover 10.UL_INTRA_FREQUENCY_ULB:WhethertoenableRTWPbasedintrafrequencyloadbalancingalgorithm.ThisalgorithmadjustsPCPICHtransmitpowerofacellbas
150217 fromUMTStoLTE 11.UL_UU_CLB:WhethertoenabletheuplinkloadbasedCLBalgorithm.ThisalgorithmdetermineswhetheracellenterstheCLBstatebytheuplinkloadontheairinterfa
WRFD SRVCCfromLTEtoUMTS 12.DL_UU_CLB:WhethertoenablethedownlinkloadbasedCLBalgorithm.ThisalgorithmdetermineswhetheracellenterstheCLBstatebythedownlinkloadontheairi
150215 withPSHandover 13.CELL_CODE_CLB:WhethertoenablecoderesourcebasedCLBalgorithm.ThisalgorithmdetermineswhetheracellenterstheCLBstatebythecoderesourceusage.
WRFD HSDPAAdmissionControl 14.CELL_CREDIT_CLB:WhethertoenablecreditbasedCLBalgorithm.ThisalgorithmdetermineswhetheracellenterstheCLBstatebythecreditresourceusage.Iface
01061003 LoadMeasurement 15.DLLOAD_BASED_PCPICH_PWR_ADJ_SWITCH:Whethertoenabledownlinkloadbaseddynamicprimarycommonpilotchannel(PCPICH)poweradjustmentalgorit
WRFD MOCNCellResource 16.ADAPTIVE_RACH:FunctionswitchfortheadaptiveRACHfeature.Whenthisswitchisturnedon,thisfeatureisactivated.Inthiscase,theRNCadjuststherandoma
020102 Demarcation 17.ACK_PRACH_PREAM_MEAS:WhethertomeasurethenumberofacknowledgedPRACHpreambles.Whenthisswitchisturnedon,theRNCmeasuresthenumbero
WRFD LoadBasedDynamic
140223 18.CAMPING_STRATEGY_SWITCH:Whethertoenablethecampingpolicyswitchingfunctionwhentrafficisheavy.Thisisafunctionswitchforthefunction.Whenthes
AdjustmentofPCPICH
WRFD 19.INTERFREQ_HHO_IN_RTWP_SWITCH:WhethertheRNCconsiderstheRTWPofthecellduringincomingcoveragebasedinterfrequencyhandoverstothiscell.Wh
AdmissionControl "InterFreqInUlCovLimitThld"parameterinthe"ADDUCELLINTERFREQHOCOV"command.Whenthisswitchisturnedoff,whethertheRNCconsiderstheuplinkcoverag
150236 FastReturnfromUMTSto
WRFD GUIValueRange:INTRA_FREQUENCY_LDB,PUC,UL_UU_LDR,DL_UU_LDR,UL_UU_OLC,DL_UU_OLC,OLC_EVENTMEAS,CELL_CODE_LDR,CELL_CREDIT
LTE
020101 Unit:None
OverloadControl
WRFD ActualValueRange:INTRA_FREQUENCY_LDB,PUC,UL_UU_LDR,DL_UU_LDR,UL_UU_OLC,DL_UU_OLC,OLC_EVENTMEAS,CELL_CODE_LDR,CELL_CRED
IntraFrequencyLoadBalance
140226 DefaultValue:
PotentialUserControl INTRA_FREQUENCY_LDB:0,PUC:0,UL_UU_LDR:0,DL_UU_LDR:0,UL_UU_OLC:0,DL_UU_OLC:0,OLC_EVENTMEAS:0,CELL_CODE_LDR:0,CELL_CREDIT_LDR:0,U
WRFD
MobilityBetweenUMTSand
020107
LTEPhase1
WRFD
HSUPAAdmissionControl
020104
PSServiceRedirectionfrom
WRFD
UMTStoLTE
020105
MBMSFLC(FrequencyLayer
WRFD
Convergence)/FLD(Frequency
020126
LayerDispersion)
WRFD
FACHTransmissionSharing
01061202
forMBMS
WRFD
InterFrequencyLoadBalance
020129
MBMSPhase2
WRFD
010626 MBMSoverIur
DynamicPowerEstimation
forMTCH

http://127.0.0.1:52199/hedex/hdx.do?lib=GEE0116P&v=11&id=ENUS_BOOKMAP_0001792561&tocURL=resources%252fen%252dus%255fbookmap%255f0001792561%252ehtml&p=t&fe=1&ui=3&keyword=puc 8/14
12/22/2016 PotentialUserControlFeatureParameterDescription
WRFD MSCHScheduling
ParameterID NE MMLCommand Feature FeatureName Description
010627 MBMSChannelAudience
ID
WRFD RatingStatistics
020103 CSFallbackGuaranteefor
WRFD LTEEmergencyCalls
010660 InterFrequencyNeighboring
WRFD CellSelectionforMBMSPTP
010661 Users
WRFD StreamingServiceonMBMS
010662 MBMSP2PoverHSDPA
WRFD MBMSAdmission
010663 Enhancement
WRFD MBMSEnhancedBroadcast
010665 Mode
WRFD MBMSTransportResource
140102 Management
WRFD OpenLoopPowerControl
01066004 CoverageBasedPS
WRFD HandoverfromUMTStoLTE
01061606 MBMSBroadcastMode
WRFD MBMSLoadControl
01066002
MBMSAdmissionControl
WRFD
InterFrequencyLoad
01066003
BalancingBasedon
WRFD ConfigurableLoadThreshold
01066001
MBMSSoft/Selective
WRFD Combining
01061605
MBMSIntroductionPackage
WRFD
16/32/64/128KbpsChannel
020501
RateonMBMS
WRFD
ServiceBasedPSHandover
150220
fromUMTStoLTE
WRFD
01061601
WRFD
01061603
WRFD
01061602
WRFD
140217
WRFD
01061604
WRFD
010616
WRFD
01061608
WRFD
140218

NBMLdcAlgoSwitch BSC6910 ADD WRFD CampingStrategySwitchfor Meaning:


UCELLALGOSWITCH 151203 MassEvent Whethertoenablethealgorithmsrelatedtocellloadcontrol.Selectingaswitchenablesthecorrespondingalgorithmandclearingaswitchdisablesthecorrespondingalgorit
MOD WRFD LoadReshuffling 1.INTRA_FREQUENCY_LDB:Whethertoenablethecellbreathingalgorithm.ThisalgorithmadjustsPCPICHtransmitpowerofacellbasedonthedownlinkTCPloadto
UCELLALGOSWITCH 020106 SelfOptimizationUnder 2.PUC:WhethertoenablethePotentialUserControl(PUC)algorithm.ThisalgorithmadjustscellselectionandreselectionparametersbasedonthecellloadtoenableUE
WRFD UplinkInterference 3.UL_UU_LDR:Whethertoenabletheuplinkloadreshuffling(LDR)algorithm.Whentheuplinkloadisheavyinacell,thisalgorithmalleviatestheuplinkloadbyusingload
171213 RIMBasedUMTSTargetCell 4.DL_UU_LDR:WhethertoenablethedownlinkLDRalgorithm.Whenthedownlinkloadisheavyinacell,thisalgorithmalleviatesthedownlinkloadbyusingloadbasedi
WRFD SelectionforLTE
5.UL_UU_OLC:Whethertoenabletheuplinkoverloadcontrol(OLC)algorithm.Whentheuplinkpowerisoverloadedinacell,thisalgorithmalleviatestheuplinkloadbyus
150231 CoverageBasedPS
6.DL_UU_OLC:WhethertoenablethedownlinkOLCalgorithm.Whenthedownlinkpowerisoverloadedinacell,thisalgorithmalleviatesthedownlinkloadbyusingquick
WRFD RedirectionfromUMTSto
150219 LTE 7.OLC_EVENTMEAS:WhethertoenableOLCeventmeasurement.
WRFD LoadBasedPSRedirection 8.CELL_CODE_LDR:Whethertoenablecellcodereshufflingalgorithm.Intheeventofcoderesourceoveruse,thisalgorithmalleviatesthecoderesourceoverusebyusing
150216 fromUMTStoLTE 9.CELL_CREDIT_LDR:Whethertoenablethecellcreditreshufflingalgorithm.Intheeventofcellcreditoveruse,thisalgorithmalleviatesthecreditoverusebyusingloadb
WRFD LoadBasedPSHandover 10.UL_INTRA_FREQUENCY_ULB:WhethertoenableRTWPbasedintrafrequencyloadbalancingalgorithm.ThisalgorithmadjustsPCPICHtransmitpowerofacellbas
150217 fromUMTStoLTE 11.UL_UU_CLB:WhethertoenabletheuplinkloadbasedCLBalgorithm.ThisalgorithmdetermineswhetheracellenterstheCLBstatebytheuplinkloadontheairinterfa
WRFD SRVCCfromLTEtoUMTS 12.DL_UU_CLB:WhethertoenablethedownlinkloadbasedCLBalgorithm.ThisalgorithmdetermineswhetheracellenterstheCLBstatebythedownlinkloadontheairi
150215 withPSHandover 13.CELL_CODE_CLB:WhethertoenablecoderesourcebasedCLBalgorithm.ThisalgorithmdetermineswhetheracellenterstheCLBstatebythecoderesourceusage.
HSDPAAdmissionControl

http://127.0.0.1:52199/hedex/hdx.do?lib=GEE0116P&v=11&id=ENUS_BOOKMAP_0001792561&tocURL=resources%252fen%252dus%255fbookmap%255f0001792561%252ehtml&p=t&fe=1&ui=3&keyword=puc 9/14
12/22/2016 PotentialUserControlFeatureParameterDescription
WRFD LoadMeasurement 14.CELL_CREDIT_CLB:WhethertoenablecreditbasedCLBalgorithm.ThisalgorithmdetermineswhetheracellenterstheCLBstatebythecreditresourceusage.Iface
ParameterID NE MMLCommand Feature FeatureName Description
01061003 MOCNCellResource 15.DLLOAD_BASED_PCPICH_PWR_ADJ_SWITCH:Whethertoenabledownlinkloadbaseddynamicprimarycommonpilotchannel(PCPICH)poweradjustmentalgorit
ID
WRFD Demarcation 16.ADAPTIVE_RACH:FunctionswitchfortheadaptiveRACHfeature.Whenthisswitchisturnedon,thisfeatureisactivated.Inthiscase,theRNCadjuststherandoma
020102 LoadBasedDynamic 17.ACK_PRACH_PREAM_MEAS:WhethertomeasurethenumberofacknowledgedPRACHpreambles.Whenthisswitchisturnedon,theRNCmeasuresthenumbero
WRFD AdjustmentofPCPICH 18.CAMPING_STRATEGY_SWITCH:Whethertoenablethecampingpolicyswitchingfunctionwhentrafficisheavy.Thisisafunctionswitchforthefunction.Whenthes
140223 AdmissionControl 19.INTERFREQ_HHO_IN_RTWP_SWITCH:WhethertheRNCconsiderstheRTWPofthecellduringincomingcoveragebasedinterfrequencyhandoverstothiscell.Wh
WRFD FastReturnfromUMTSto "InterFreqInUlCovLimitThld"parameterinthe"ADDUCELLINTERFREQHOCOV"command.Whenthisswitchisturnedoff,whethertheRNCconsiderstheuplinkcoverag
150236 LTE GUIValueRange:INTRA_FREQUENCY_LDB,PUC,UL_UU_LDR,DL_UU_LDR,UL_UU_OLC,DL_UU_OLC,OLC_EVENTMEAS,CELL_CODE_LDR,CELL_CREDIT
WRFD OverloadControl Unit:None
020101 IntraFrequencyLoadBalance ActualValueRange:INTRA_FREQUENCY_LDB,PUC,UL_UU_LDR,DL_UU_LDR,UL_UU_OLC,DL_UU_OLC,OLC_EVENTMEAS,CELL_CODE_LDR,CELL_CRED
WRFD PotentialUserControl
140226 DefaultValue:
MobilityBetweenUMTSand INTRA_FREQUENCY_LDB:0,PUC:0,UL_UU_LDR:0,DL_UU_LDR:0,UL_UU_OLC:0,DL_UU_OLC:0,OLC_EVENTMEAS:0,CELL_CODE_LDR:0,CELL_CREDIT_LDR:0,U
WRFD LTEPhase1
020107
HSUPAAdmissionControl
WRFD
PSServiceRedirectionfrom
020104
UMTStoLTE
WRFD
MBMSFLC(FrequencyLayer
020105
Convergence)/FLD(Frequency
WRFD LayerDispersion)
020126
FACHTransmissionSharing
WRFD forMBMS
01061202
InterFrequencyLoadBalance
WRFD
MBMSPhase2
020129
MBMSoverIur
WRFD
010626 DynamicPowerEstimation
forMTCH
WRFD
010627 MSCHScheduling
WRFD MBMSChannelAudience
020103 RatingStatistics
WRFD CSFallbackGuaranteefor
010660 LTEEmergencyCalls
WRFD InterFrequencyNeighboring
010661 CellSelectionforMBMSPTP
Users
WRFD
010662 StreamingServiceonMBMS
WRFD MBMSP2PoverHSDPA
010663 MBMSAdmission
WRFD Enhancement
010665 MBMSEnhancedBroadcast
WRFD Mode
140102 MBMSTransportResource
WRFD Management
01066004 OpenLoopPowerControl
WRFD CoverageBasedPS
01061606 HandoverfromUMTStoLTE
WRFD MBMSBroadcastMode
01066002 MBMSLoadControl
WRFD MBMSAdmissionControl
01066003 InterFrequencyLoad
WRFD BalancingBasedon
01066001 ConfigurableLoadThreshold
WRFD MBMSSoft/Selective
01061605 Combining
WRFD MBMSIntroductionPackage
020501 16/32/64/128KbpsChannel
WRFD RateonMBMS
150220 ServiceBasedPSHandover
WRFD fromUMTStoLTE
01061601
WRFD
01061603
WRFD
01061602
WRFD
140217
http://127.0.0.1:52199/hedex/hdx.do?lib=GEE0116P&v=11&id=ENUS_BOOKMAP_0001792561&tocURL=resources%252fen%252dus%255fbookmap%255f0001792561%252ehtml&p=t&fe=1&ui=3&keyword=puc 10/14
12/22/2016 PotentialUserControlFeatureParameterDescription

ParameterID NE MMLCommand WRFD


Feature FeatureName Description
01061604
ID
WRFD
010616
WRFD
01061608
WRFD
140218

SpucHeavy BSC6900 ADDUCELLPUC WRFD PotentialUserControl Meaning:


MODUCELLPUC 020105 Whethertheloadlevelofacellisheavy.ThisparameterisdenotedbytheratioofNodeBTXpowertothemaximumTXpower.
Iftheloadofacellishigherthanorequaltothisthresholdplusthevalueofthe"SpucHyst"parameter,theloadlevelofthiscellisheavy.
Iftheloadlevelofacellisheavy,thePUCalgorithmwillconfigureselection/reselectionparametersforthiscelltoinstructtheUEcampingonthiscelltoreselectanotherin
GUIValueRange:0~100
Unit:%
ActualValueRange:0~100
DefaultValue:70

SpucHeavy BSC6910 ADDUCELLPUC WRFD PotentialUserControl Meaning:


MODUCELLPUC 020105 Whethertheloadlevelofacellisheavy.ThisparameterisdenotedbytheratioofNodeBTXpowertothemaximumTXpower.
Iftheloadofacellishigherthanorequaltothisthresholdplusthevalueofthe"SpucHyst"parameter,theloadlevelofthiscellisheavy.
Iftheloadlevelofacellisheavy,thePUCalgorithmwillconfigureselection/reselectionparametersforthiscelltoinstructtheUEcampingonthiscelltoreselectanotherin
GUIValueRange:0~100
Unit:%
ActualValueRange:0~100
DefaultValue:70

SpucHyst BSC6900 ADDUCELLPUC WRFD PotentialUserControl Meaning:Hysteresisfordeterminingthecellloadlevel.ThisparameterisdenotedbytheratioofNodeBTXpowertothemaximumTXpower.Thisparameterisusedtoprev


MODUCELLPUC 020105 GUIValueRange:0~100
Unit:%
ActualValueRange:0~100
DefaultValue:5

SpucHyst BSC6910 ADDUCELLPUC WRFD PotentialUserControl Meaning:Hysteresisfordeterminingthecellloadlevel.ThisparameterisdenotedbytheratioofNodeBTXpowertothemaximumTXpower.Thisparameterisusedtoprev


MODUCELLPUC 020105 GUIValueRange:0~100
Unit:%
ActualValueRange:0~100
DefaultValue:5

SpucLight BSC6900 ADDUCELLPUC WRFD PotentialUserControl Meaning:


MODUCELLPUC 020105 Whethertheloadlevelofacellislight.ThisparameterisdenotedbytheratioofNodeBTXpowertothemaximumTXpower.
Iftheloadofacellislowerthanorequaltothisthresholdplusthevalueofthe"SpucHyst"parameter,theloadlevelofthiscellislight.
Iftheloadlevelofacellislight,thePUCalgorithmwillconfigureselection/reselectionparametersforthiscelltoinstructtheUEcampingonaninterfrequencyneighboringc
GUIValueRange:0~100
Unit:%
ActualValueRange:0~100
DefaultValue:45

SpucLight BSC6910 ADDUCELLPUC WRFD PotentialUserControl Meaning:


MODUCELLPUC 020105 Whethertheloadlevelofacellislight.ThisparameterisdenotedbytheratioofNodeBTXpowertothemaximumTXpower.
Iftheloadofacellislowerthanorequaltothisthresholdplusthevalueofthe"SpucHyst"parameter,theloadlevelofthiscellislight.
Iftheloadlevelofacellislight,thePUCalgorithmwillconfigureselection/reselectionparametersforthiscelltoinstructtheUEcampingonaninterfrequencyneighboringc
GUIValueRange:0~100
Unit:%
ActualValueRange:0~100
DefaultValue:45

OffSinterLight BSC6900 ADDUCELLPUC WRFD PotentialUserControl Meaning:Cellreselectionstartoffsetwhentheloadlevelofthecentercellislight.Whentheloadlevelofthecentercellislight,thevalueofthe"Sintersearch"parameterpl


MODUCELLPUC 020105 GUIValueRange:10~10
Unit:2dB
ActualValueRange:20~20
DefaultValue:2

http://127.0.0.1:52199/hedex/hdx.do?lib=GEE0116P&v=11&id=ENUS_BOOKMAP_0001792561&tocURL=resources%252fen%252dus%255fbookmap%255f0001792561%252ehtml&p=t&fe=1&ui=3&keyword=puc 11/14
12/22/2016 PotentialUserControlFeatureParameterDescription

ParameterID NE MMLCommand Feature FeatureName Description


ID

OffSinterLight BSC6910 ADDUCELLPUC WRFD PotentialUserControl Meaning:Cellreselectionstartoffsetwhentheloadlevelofthecentercellislight.Whentheloadlevelofthecentercellislight,thevalueofthe"Sintersearch"parameterpl


MODUCELLPUC 020105 GUIValueRange:10~10
Unit:2dB
ActualValueRange:20~20
DefaultValue:2

OffSinterHeavy BSC6900 ADDUCELLPUC WRFD PotentialUserControl Meaning:Cellreselectionstartoffsetwhentheloadlevelofthecentercellisheavy.Whentheloadlevelofthecentercellisheavy,thevalueofthe"Sintersearch"paramete


MODUCELLPUC 020105 25.304.
GUIValueRange:10~10
Unit:2dB
ActualValueRange:20~20
DefaultValue:2

OffSinterHeavy BSC6910 ADDUCELLPUC WRFD PotentialUserControl Meaning:Cellreselectionstartoffsetwhentheloadlevelofthecentercellisheavy.Whentheloadlevelofthecentercellisheavy,thevalueofthe"Sintersearch"paramete


MODUCELLPUC 020105 25.304.
GUIValueRange:10~10
Unit:2dB
ActualValueRange:20~20
DefaultValue:2

OffQoffset1Light BSC6900 ADDUCELLPUC WRFD PotentialUserControl Meaning:Celloffset1whentheloadofaneighboringcellislighterthanthatofthecentercell.Whentheloadofaneighboringcellislighterthanthatofthecentercell,thev


MODUCELLPUC 020105 GUIValueRange:20~20
Unit:dB
ActualValueRange:20~20
DefaultValue:4

OffQoffset1Light BSC6910 ADDUCELLPUC WRFD PotentialUserControl Meaning:Celloffset1whentheloadofaneighboringcellislighterthanthatofthecentercell.Whentheloadofaneighboringcellislighterthanthatofthecentercell,thev


MODUCELLPUC 020105 GUIValueRange:20~20
Unit:dB
ActualValueRange:20~20
DefaultValue:4

OffQoffset2Light BSC6900 ADDUCELLPUC WRFD PotentialUserControl Meaning:Celloffset2whentheloadofaneighboringcellislighterthanthatofthecentercell.Whentheloadofaneighboringcellislighterthanthatofthecentercell,thev


MODUCELLPUC 020105 GUIValueRange:20~20
Unit:dB
ActualValueRange:20~20
DefaultValue:4

OffQoffset2Light BSC6910 ADDUCELLPUC WRFD PotentialUserControl Meaning:Celloffset2whentheloadofaneighboringcellislighterthanthatofthecentercell.Whentheloadofaneighboringcellislighterthanthatofthecentercell,thev


MODUCELLPUC 020105 GUIValueRange:20~20
Unit:dB
ActualValueRange:20~20
DefaultValue:4

OffQoffset1Heavy BSC6900 ADDUCELLPUC WRFD PotentialUserControl Meaning:Celloffset1whentheloadofaneighboringcellisheavierthanthatofthecentercell.Whentheloadofaneighboringcellisheavierthanthatofthecentercell,the


MODUCELLPUC 020105 GUIValueRange:20~20
Unit:dB
ActualValueRange:20~20
DefaultValue:4

OffQoffset1Heavy BSC6910 ADDUCELLPUC WRFD PotentialUserControl Meaning:Celloffset1whentheloadofaneighboringcellisheavierthanthatofthecentercell.Whentheloadofaneighboringcellisheavierthanthatofthecentercell,the


MODUCELLPUC 020105 GUIValueRange:20~20
Unit:dB
ActualValueRange:20~20
DefaultValue:4

http://127.0.0.1:52199/hedex/hdx.do?lib=GEE0116P&v=11&id=ENUS_BOOKMAP_0001792561&tocURL=resources%252fen%252dus%255fbookmap%255f0001792561%252ehtml&p=t&fe=1&ui=3&keyword=puc 12/14
12/22/2016 PotentialUserControlFeatureParameterDescription

ParameterID NE MMLCommand Feature FeatureName Description


ID

OffQoffset2Heavy BSC6900 ADDUCELLPUC WRFD PotentialUserControl Meaning:Celloffset2whentheloadofaneighboringcellisheavierthanthatofthecentercell.Whentheloadofaneighboringcellisheavierthanthatofthecentercell,the


MODUCELLPUC 020105 GUIValueRange:20~20
Unit:dB
ActualValueRange:20~20
DefaultValue:4

OffQoffset2Heavy BSC6910 ADDUCELLPUC WRFD PotentialUserControl Meaning:Celloffset2whentheloadofaneighboringcellisheavierthanthatofthecentercell.Whentheloadofaneighboringcellisheavierthanthatofthecentercell,the


MODUCELLPUC 020105 GUIValueRange:20~20
Unit:dB
ActualValueRange:20~20
DefaultValue:4

PucPeriodTimerLen BSC6900 SETULDCPERIOD WRFD PotentialUserControl Meaning:PeriodofstartingPUC.Ifacellisheavilyloaded,cellselectionandreselectionparametersareadjustedperiodicallysothatUEsinnonconnectedmodecanbem


020105 GUIValueRange:6~115300
Unit:s
ActualValueRange:6~115300
DefaultValue:1800

PucPeriodTimerLen BSC6910 SETULDCPERIOD WRFD PotentialUserControl Meaning:PeriodofstartingPUC.Ifacellisheavilyloaded,cellselectionandreselectionparametersareadjustedperiodicallysothatUEsinnonconnectedmodecanbem


020105 GUIValueRange:6~115300
Unit:s
ActualValueRange:6~115300
DefaultValue:1800

6Counters
Table61Counters

CounterID CounterName CounterDescription NE FeatureID FeatureName

67189856 VS.PUC.High.Offset.Updt NumberofQoffsetUpdatesDueto BSC6900 WRFD020105 PotentialUserControl


HeavyLoadforCell

67189856 VS.PUC.High.Offset.Updt NumberofQoffsetUpdatesDueto BSC6910 WRFD020105 PotentialUserControl


HeavyLoadforCell

67189857 VS.PUC.Light.Offset.Updt NumberofQoffsetUpdatesDuetoLight BSC6900 WRFD020105 PotentialUserControl


LoadforCell

67189857 VS.PUC.Light.Offset.Updt NumberofQoffsetUpdatesDuetoLight BSC6910 WRFD020105 PotentialUserControl


LoadforCell

67189858 VS.PUC.Norm.Offset.Updt NumberofQoffsetUpdatesDueto BSC6900 WRFD020105 PotentialUserControl


NormalLoadforCell

67189858 VS.PUC.Norm.Offset.Updt NumberofQoffsetUpdatesDueto BSC6910 WRFD020105 PotentialUserControl


NormalLoadforCell

67190442 VS.PUC.Light.IntSrch.Updt NumberofSintersearchUpdatesDueto BSC6900 WRFD020105 PotentialUserControl


LightLoadforCell

67190442 VS.PUC.Light.IntSrch.Updt NumberofSintersearchUpdatesDueto BSC6910 WRFD020105 PotentialUserControl


LightLoadforCell

67190443 VS.PUC.Norm.IntSrch.Updt NumberofSintersearchUpdatesDueto BSC6900 WRFD020105 PotentialUserControl


NormalLoadforCell

67190443 VS.PUC.Norm.IntSrch.Updt NumberofSintersearchUpdatesDueto BSC6910 WRFD020105 PotentialUserControl


NormalLoadforCell

67190444 VS.PUC.High.IntSrch.Updt NumberofSintersearchUpdatesDueto BSC6900 WRFD020105 PotentialUserControl


HeavyLoadforCell

http://127.0.0.1:52199/hedex/hdx.do?lib=GEE0116P&v=11&id=ENUS_BOOKMAP_0001792561&tocURL=resources%252fen%252dus%255fbookmap%255f0001792561%252ehtml&p=t&fe=1&ui=3&keyword=puc 13/14
12/22/2016 PotentialUserControlFeatureParameterDescription

CounterID CounterName CounterDescription NE FeatureID FeatureName

67190444 VS.PUC.High.IntSrch.Updt NumberofSintersearchUpdatesDueto BSC6910 WRFD020105 PotentialUserControl


HeavyLoadforCell

7Glossary
Fortheacronyms,abbreviations,terms,anddefinitions,seeGlossary.

8ReferenceDocuments
None

http://127.0.0.1:52199/hedex/hdx.do?lib=GEE0116P&v=11&id=ENUS_BOOKMAP_0001792561&tocURL=resources%252fen%252dus%255fbookmap%255f0001792561%252ehtml&p=t&fe=1&ui=3&keyword=puc 14/14

You might also like