Main Wind Resisting System AVERAGE WALL PRESSURE : For overturning calculations. WALL LINE PRESSURE AND HEIGHT ABOVE GROUND ACROSS WALLS 1 AND 2 LOAD = 2317.20 lb/ft HEIGHT ABOVE GROUND = 40.4 ft ACROSS WALLS 3 LOAD = 2309.10 LB/FT HEIGHT ABOVE GROUND = 40.4 ft MAXIMUM ROOF LOAD MAX POS = 10.00 psf MAX NEG = -34.93 psf
WALL PRESSURE OUTPUT (psf)
-------------------------- WALLS 1 AND 2 HEIGHT WINDWARD LEEWARD SIDE ABS WIND+LEE(NO Internal) -------------------------------------------------------------------------------- ------------------- 1 16.7 -16.9 -22.3 26.6 6 16.7 -16.9 -22.3 26.6 11 16.7 -16.9 -22.3 26.6 16 17.1 -16.9 -22.3 27.1 21 18.1 -16.9 -22.3 28.0 26 19.0 -16.9 -22.3 28.9 31 19.9 -16.9 -22.3 29.9 36 20.6 -16.9 -22.3 30.5 41 21.3 -16.9 -22.3 31.2 46 21.8 -16.9 -22.3 31.7 51 22.4 -16.9 -22.3 32.4 56 22.9 -16.9 -22.3 32.9 61 23.4 -16.9 -22.3 33.3 66 23.8 -16.9 -22.3 33.8 71 24.3 -16.9 -22.3 34.2 76 24.5 -16.9 -22.3 34.5 WALLS 3 HEIGHT WINDWARD LEEWARD SIDE ABS WIND+LEE(NO Internal) -------------------------------------------------------------------------------- ------------------- 1 16.7 -16.8 -22.3 26.5 6 16.7 -16.8 -22.3 26.5 11 16.7 -16.8 -22.3 26.5 16 17.1 -16.8 -22.3 27.0 21 18.1 -16.8 -22.3 27.9 26 19.0 -16.8 -22.3 28.8 31 19.9 -16.8 -22.3 29.7 36 20.6 -16.8 -22.3 30.4 41 21.3 -16.8 -22.3 31.1 46 21.8 -16.8 -22.3 31.6 51 22.4 -16.8 -22.3 32.3 56 22.9 -16.8 -22.3 32.8 61 23.4 -16.8 -22.3 33.2 66 23.8 -16.8 -22.3 33.7 71 24.3 -16.8 -22.3 34.1 76 24.5 -16.8 -22.3 34.4 ROOF OUTPUT PRESSURES (psf) DIST FROM WINDWARD EDGE. POS NEG -------------------------------- 0.0 TO 41.0 10.0 -34.9 41.0 TO 82.0 10.0 -22.3 82.0 TO 164.0 10.0 -22.3 164.0 TO END 10.0 -22.3 CONSTANTS USED Dim Perp. to Ridge = 25.20 ft Dim Parallel to Ridge = 25.70 ft Roof Angle = 3.65 deg. Mean Roof Height = 82.00 ft Wall Height = 76.20 ft Max Height of Openings = 6.20 ft Gust Factor Walls 1, 2 = 0.85 Gust Factor Walls 3 = 0.85 Gust Factor Roofs = 0.85 Wind Speed, V = 125.0 mph Exposure Cat. = B Importance Cat. = 2 Internal Pressure Exposure coef., Kzi = 0.57 Internal Velocity Pressure, qi = 19.38 psf Internal Pressure Coef., GCPi = 0.18 Topographic Factor, Kzt = 1.00 Wind Direction Factor, Kd = 0.85 MAIN PRESSURE EQUATIONS ARE AS FOLLOWS: P = qGCp-qi(GCpi) or P = qGCp+qI(GCpi) The worst case of the above are used. If any component across the walls is less than 10 psf, 10 psf is used as a minimum pressure. Constants are described as follows: qi, Internal Velocity Pressure q, Velocity Pressure Kz, Velocity Pressure Exposure Coef. Cp, External Pressure Coef. Main wind force resisting systems are based on ASCE 7-98 Section 6.5.12.2 CONSTANTS FOR WALLS 1 AND 2: TREATED AS WINDWARD SIDE Kz at Bottom of Wall = 0.57 Kz at Top of Wall = 0.91 q at Bottom of Wall = 19.38 psf q at Top of Wall = 30.94 psf Cp at Bottom of Wall = 0.8 Cp at Top of Wall = 0.8 TREATED AS LEEWARD SIDE Kz = 0.93 q = 31.62 Cp = -0.50 TREATED AS SIDE WALLS Kz = 0.93 q = 31.62 Cp = -0.70 CONSTANTS FOR WALLS 3: TREATED AS WINDWARD SIDE Kz at Bottom of Wall = 0.57 Kz at Top of Wall = 0.91 q at Bottom of Wall = 19.38 psf q at Top of Wall = 30.94 psf Cp at Bottom of Wall = 0.8 Cp at Top of Wall = 0.8 TREATED AS LEEWARD SIDE Kz = 0.93 q = 31.62 Cp = -0.50 TREATED AS SIDE WALLS Kz = 0.93 q = 31.62 Cp = -0.70 CONSTANTS FOR ROOF: Kz = 0.93 q = 31.62 psf Cp values vary and are based on ASCE 7, fig. 6-3