You are on page 1of 2

FLOW CONTROL

Introducing Camerons HIGH FLOW CIMV


(Chemical Injection Metering Valve)
THE CIMV ADVANTAGE

Innovatively simple

Engineered for wide flow


turndown with fine
flow control

Non-intrusive ultrasonic
flow measurement

Onboard closed loop control

The ultimate in accuracy and


reliability

Insert-retrievable, self-regulating metering valve


for MEG and methanol
Camerons HIGH FLOW CIMV (Chemical Injection Metering Valve)
has been developed through the Design for Six Sigma (DFSS) stage
gate process, with Voice of Customer (VOC) used to focus product
development.

The HIGH FLOW CIMV is the latest development in this successful


product family. The HIGH FLOW CIMV is an insert-retrievable, self
regulating chemical injection metering valve with a flow range of 160
26,500 l/h (42 7000 gal/h). Flow metering accuracy is better than 5%
of reading. An innovative, non-intrusive CALDON Ultrasonic Flow Meter,
developed in conjunction with Camerons Valves & Measurement group,
is at the core of the technology. This advanced transit time, non-intrusive
ultrasonic flow meter is ideally suited for applications using regenerated or
slipstream MEG.

RAISING PERFORMANCE. TOGETHER


FLOW CONTROL

TECHNICAL SPECIFICATION
Insert-retrievable self-regulating
metering valve
Flow range 160 - 26,500l/h
(42 - 7,000 gal/h)
Turn down exceeds 166:1
Metering accuracy better than 5%
of reading
Application MEG, methanol, other
Flow meter non-intrusive ultrasonic
Throttling valve MOV (Multiple Orifice
Valve)
Actuation low power electric motor
Control onboard, closed loop with
diagnostics
Independent secondary flow measurement
Power <12 watts operating, <3 watts
quiescent
Communication SIIS Level 2 CANbus
10,000 psi MWP
-5 C to 70 C (23 F to 158 F) operating
temperature
Primary metal-to-metal sealing throughout,
duplex wetted bores, hydrocarbon tolerant
Insert weight in water 250 kg (550 lbs) approx. PROACTIVE QUALIFICATION
No subsea filtration necessary, large 1.5 flow Cameron has completed rigorous and comprehensive
path throughout qualification and field simulation testing in our labs to
ensure our new High Flow CIMV provides outstanding
The HIGH FLOW CIMV is mounted long-term performance in the field.
horizontally in a tree or manifold
API 6A Appendix F PR2 (Modified)
and intervention is performed via a
Hyperbaric
wireline or buoyancy with ROV-assist.
Endurance Flow Test
Lockdown is provided by a field-
Particulate Testing
proven dog-in-window connector
Chemical Testing
operated by ROV torque tool.

Please contact a Cameron representative


for more information

Cameron Ireland Ltd.


Aghafad, Longford
Republic of Ireland.
Tel: +353.43.335.0600

Visit our website at www.c-a-m.com

2010 Cameron | HIGH FLOW CIMV is a trademark of Cameron, CALDON is a registered trademark of Cameron | Printed in USA | 04/10 TC9831

You might also like