You are on page 1of 36

Phone:886-2-2767-3510 Http://www.sjcom.com.

tw

LABORATORY
FURNACES
BOX
FURNACES
TUBE
FURNACES
CRUCIBLE
FURNACES
CONTROLLERS
HOT PLATES


Phone:886-2-2767-3510 Http://www.sjcom.com.tw

Lindberg/Blue M Furnaces
Box Furnaces Tube Furnaces Crucible Furnaces

The Lindberg/Blue M product line offers a Applications for Lindberg/Blue M Tube Lindberg/Blue M Crucible Furnaces
versatile selection of small, medium and Furnaces include high temperature air create safe, energy efficient, high
large chamber box furnaces suitable for a and atmosphere processes in horizontal temperature performance for melting,
variety of industrial and laboratory appli- or vertical configurations. Single and sintering, annealing and atmosphere
cations.Advanced engineering and spe- three-zone designs create precise processing. Microprocessor-based
cialized construction techniques include temperature uniformity.Temperature independent control systems assure accu-
variable density insulation, double shell controllers offer a range of sophistication, racy and repeatability.
cabinets, long-life heating elements and including microprocessor-based
1200C Crucible Furnace,
vertical, horizontal side swing or swing single and multi-setpoint programmable
Top Loading . . . . . . . . . . . . . . .30-31
down doors. controls.
1700C Crucible Furnace, Top
1100C Moldatherm Mini-Mite 1100C Tube or Bottom Loading . . . . . . . . . .32-33
Box Furnaces . . . . . . . . . . . . . . . .4-5 Furnace, Single Zone . . . . . . . .16-17
1200C LGO 1100C Tube Furnaces, Hot Plates
Box Furnaces . . . . . . . . . . . . . . . .6-7 Three Zone . . . . . . . . . . . . . . . .18-19
Lindberg/Blue M Hot Plates provide large
1200C Box Furnaces, 1200C Split-Hinge Tube surface heating up to 400C for general
Heavy-Duty . . . . . . . . . . . . . . . . . .8-9 Furnaces . . . . . . . . . . . . . . . . . .20-23 purpose applications.
1500C Box Furnaces, Multi- 1500C Tube Furnace,
Purpose, Integral Control . . . . . .10 Heavy-Duty, Independent 400C Hot Plate,
1500C Box Furnace, Heavy- Control . . . . . . . . . . . . . . . . . . . .24-26 Solid-State Control . . . . . . . . . . . . .34
Duty, Independent Control . . . . . .11 1500C Tube Furnace, General 400C Hot Plate,
1700C Box Furnace, Purpose, Integral Control . . . . . .27 3-Switch On/Off Control . . . . . . . .34
Independent Control . . . . . . . .12-13 1700C Tube Furnaces, High
1700C Box Furnace, Large Controllers and Accessories
Temperature, Independent
Chamber, Integral Control . . .14-15 Control . . . . . . . . . . . . . . . . . . . .28-29 Controllers and Accessories . . . .35

2 Some questions to consider when selecting a Lindberg/Blue M furnace for your application
1. What temperature is needed for the application? What size process tube will be used in the furnace?
Lindburg/Blue M furnaces are listed by increasing maximum Most of our tube furnaces will accommodate a range of process
temperature; 1100C, 1200C, 1500C and 1700C. tubes due to our interchangeable tube adapters. Please see
2. What type of furnace is needed: box, tube or crucible? the specifications for each furnace model for this infromation.
Each type of furnace may be used for many different types of 4. What type of controller is needed? A single setpoint, a
applications. Here are some examples: A box furnace may be single program with multiple segments, or multiple
appropriate for processing large samples or for ease of place- programs and multiple segments?
ment and access of samples. A tube furnace may be appropri- A single setpoint provides one ramp up to one temperature
ate for processing small samples in inert atmospheres. A cru- setpoint. A single program, multiple segment controller pro-
cible furnace may be appropriate for processing samples in vides one program with multiple ramp (change in tempera-
crucibles. ture) and dwell (temperature hold) settings. A multiple pro-
3. If a tube furnace seems appropriate for the applica- gram, multiple segment controller allows multiple programs to
tion, please consider the following features: be stored in the controller memory, with each program offer-
ing multiple segments for temperature control. Please see page
Will a single zone or three zone furnace be more 35 for additional information on each type of controller.
appropriate for the application?
5. Are you concerned about saftey? Will the furnace be
A single zone furnace has one set of heating elements con-
trolled by one controller. A three zone furnace has three
left running while unattended or overnight?
groups of heating elements controlled by three controllers, We offer an Over Temperature Control (OTC) feature that pro-
one for each zone. A three zone furnace can be configured to vides a redundant, back-up thermocouple and controller to
help reduce the heat loss at the tube ends or to provide a gra- shut down the furnace if the high temperature limit is
dient temperature along the length of a sample. reached.This requires a manual reset for optimum safety.This
feature is designated by a B in the model number suffix or is
Is a split-hinge or solid tube furnace needed? available as an option on other select furnaces. Please see indi-
A hinge tube furnace allows a process tube to be easily vidual furnace specifications for additional information.
changed and removed and may be appropriate if tubes must
be changed on a frequent basis. A solid tube furnace may be Caution:
appropriate if the tube will not be changed or removed from Furnaces are not recommended for use with these substances as they may damage insulation:
the furnace on a frequent basis. Strong fluxing agents, such as alkali (sodium, potassium, boria, vanadium, and iron oxide)
Reducing conditions (oxygen depletion) environments. Example: high concentrations of
What heated length is needed? hydrogen at low dew point above 1040C would attack insulation
Fluorine and chlorine (above 650C for chlorine)
The heated length of a tube furnace refers to the area covered Phosphates above 500C
by the heating elements.The heated length is noted for each Hydrofluoric and phosphoric acids
tube furnace in the specifications. Strong bases (sodium hydroxide)



800-252-7100 www.lindbergbluem.com
Phone:886-2-2767-3510 Http://www.sjcom.com.tw

Unique right angle bend heating elements The Lindberg/Blue M product line has The LGO heating element is formed of sin-
with sidewall mounting tolerate rapid earned a reputation for safety, depend- uous shaped resistance wires partially
cycling over extended periods. Elements are ability and extended useful life with robust embedded in Moldatherm insulation to
easily replaced without the need to match sub-component assemblies scientifically create a single insulated module. Recessed
resistance values, and sidewall mounting engineered for long life in a wide range of into an open groove to amplify energy
protects integrity of chamber roof by demanding research and production release, the LGO element transfers more
eliminating roof penetrations. applications. radiant energy to the process area.

Offering the industrys largest Unique Moldatherm Insulation cost savings through quicker throughput
The patented Moldatherm ceramic fiber and energy efficiency. LGO heating
selection of box, tube and crucible elements on single and three-zone tube
insulation composite has rapid heat-up and
models used for rigorous industrial, furnaces offer superior radial and linear
cool-down properties which allow quick
scientific and laboratory research turn-around for more productive furnace temperature uniformity with exceptional
reliability.
and production. use. Moldatherm high temperature fiber is
vacuum formed around operating Power Controllers and Programmers 3
Lindberg/Blue M furnaces are useful chambers to provide efficient radiant
for materials testing and investigation, Lindberg/Blue M
energy release, excellent uniformity,
analysis, quality control and production of furnaces are
reduced operating costs and increased
ceramics, electronics, polymers and available with
resiliency to thermal shock.
chemicals.With maximum temperature built-in (integral) or
ranges from 1100C to 1700C, independent temper-
applications include ashing, sintering, ature controllers,
crystallizing, annealing, fusion, tempering depending on model
and hardening, atmosphere processing selected. Control
Microprocessor sophistication ranges
and more. Controller from solid-state sin-
gle setpoint to more versatile microproces-
Performance And Convenience sor-based systems with programming and
Design techniques such as double shell communications options.
construction and variable density insulation Integral controllers, self-contained and
combine to enhance performance over Moldatherm Graduated
Density Insulation mounted in the main control panel of the
conventional furnaces. Durable, high furnace, save space and allow easy access
strength hardware and a variety of control with quick plug-in maintenance.
systems offer both convenience and versa- Many Lindberg/Blue M furnaces feature
Independent controllers can be
tililty over a range of sophistication. compact, lightweight Moldatherm graduat-
ed density insulation which adds to safety positioned adjacent to or remote from
and performance with enhanced protec- the furnace, permitting furnaces to be
Safer To Operate, Up To 70% Cooler tion between the high temperature cham- used in fume hoods or containment areas,
Exterior temperatures of many ber and exterior cabinet surface. or installed in banks of multiple furnaces
Lindberg/Blue M furnaces are proven 70% with control cabinets centrally located or
cooler than competitive brands.* Reduced grouped for easy monitoring and control.
heat loss improves energy efficiency, and LGO Heating Element Some furnaces can be positioned or ori-
cooler exterior temperatures enhance The patented LGO heating element, ented as required (i.e. horizontal or verti-
operator safety. (light gauge overbend) a standard cal), leaving available all installation and
component on many Lindberg/Blue M box applications alternatives.
*Independent Study; test results available and tube furnaces, delivers exceptional
upon request energy release, fast heat-up and recovery,
reduced thermal process cycle time, and



800-252-7100 www.lindbergbluem.com

Box Furnaces
Phone:886-2-2767-3510 Http://www.sjcom.com.tw

The Moldatherm
1100C Box Furnace
is available with
single setpoint or
multiple segment
programmable power
controller. Each
version is available in
four sizes with a
variety of options; see
chart for ordering
information. Applications
Ashing, organic and
inorganic
Heat treating
Annealing
Tempering
Hardening
Model BF51866C Moldatherm Box Melting
Furnace designed for 100C to 1100C Fusing
operation includes high efficiency
Bonding
insulation for rapid heat-up and
energy efficient performance. Drying
Digestion of samples
Asphalt testing

4
1100C Moldatherm Box Furnaces
Lindberg/Blue M Moldatherm 1100C Removable and replaceable Digital Single Program, Multiple
box furnaces feature a choice of Moldatherm hearth plate supports load Segment Programmable Controller
microprocessor-based single setpoint or and prevents damage due to spillage Microprocessor-based control with
programmable control instrumentation. Main power on/off switch on control selectable self-tuning feature sets best
Available in four popular chamber sizes panel control parameters for the thermal
to meet the most demanding laboratory process. PID control (proportional,
applications, these furnaces include unique Safety door switch to interrupt power to
heating element when door is opened; integral, derivative) prevents overshoot
insulation and heating element composites
to minimize outer surface temperatures protects heating element and minimizes Single program with multiple segments
while maintaining uniform heat distribution exposure to end-user for ramp (up and down) and dwell
within the chamber. Available in 120V and 208/240V (timed hold) temperature control. See
configurations page 35 for more information
Features and Benefits Adjustable high limit overtemperature
Two control options Digital, Single Setpoint Controller protection
Controlled heat-up rate eliminates Microprocessor-based control with Simultaneous LED display of actual
thermal shock to materials selectable self-tuning feature sets best temperature vs. setpoint
control parameters for the thermal May be configured to display temperature
Quick heat-up and cool-down rates process. PID control (proportional, in either C or F
Energy efficient Moldatherm insulation integral, derivative) prevents overshoot
with embedded heating elements UL approval
Single segment, single setpoint, 1 ramp to
Unique double-wall construction setpoint Optional RS485 Digital
minimizes exterior surface temperatures Adjustable high limit overtemperature Communications Port
for operator safety and energy efficiency protection
RS485 Digital communications port avail-
Side-hinge door for convenient operation Simultaneous LED display of actual able as an option. Allows controller to be
and full chamber access temperature vs. setpoint connected to a PC for remote monitoring
Long-life Type K thermocouple May be configured to display temperature and control of the furnace. Up to 30 units
Air vent (1" dia., top) and air inlet (.375" in either C or F can be connected to one PC. Please see
dia., rear) for inert atmosphere exchange. UL approval page 35 for ordering information and
Will experience some leakage at door additional options



800-252-7100 www.lindbergbluem.com
Phone:886-2-2767-3510 Http://www.sjcom.com.tw

1100C Moldatherm Box Furnaces,Temperature Range 100C to 1100C

Furnace Integrated Electrical Watts Interior Dimensions Exterior Dimensions Ship Weight
Model No. Control Volts, Hz, 1 H x F-B x W in" (mm) H x F-B x W in" (mm) lbs (kg)

0.07 Cu.Ft. (1.99 liters)


BF51748A Digital/OTP 120V, 50/60 Hz 1800 4" (101.6) x 8" (203.2) x 4" (101.6) 17.5" (444.5) x 20" (508) x 15" (381) 55 (25)
BF51748C Digital/OTP 208/240V, 50/60 Hz 1800 4" (101.6) x 8" (203.2) x 4" (101.6) 17.5" (444.5) x 20" (508) x 15" (381) 55 (25)
BF51848A Multiple Seg/1 Prog/OTP 120V, 50/60 Hz 1800 4" (101.6) x 8" (203.2) x 4" (101.6) 17.5" (444.5) x 20" (508) x 15" (381) 55 (25)
BF51848C Multiple Seg/1 Prog/OTP 208/240V, 50/60 Hz 1800 4" (101.6) x 8" (203.2) x 4" (101.6) 17.5" (444.5) x 20" (508) x 15" (381) 55 (25)

0.1875 Cu.Ft. (5.3 liters)


BF51766A Digital/OTP 120V, 50/60 Hz 1800 6" (152.4) x 9" (228.6) x 6" (152.4) 21.5" (546.1) x 21" (533.4) x 17" (431.8) 110 (50)
BF51766C Digital/OTP 208/240V, 50/60 Hz 1800 6" (152.4) x 9" (228.6) x 6" (152.4) 21.5" (546.1) x 21" (533.4) x 17" (431.8) 110 (50)
BF51866A Multiple Seg/1 Prog/OTP 120V, 50/60 Hz 1800 6" (152.4) x 9" (228.6) x 6" (152.4) 21.5" (546.1) x 21" (533.4) x 17" (431.8) 110 (50)
BF51866C Multiple Seg/1 Prog/OTP 208/240V, 50/60 Hz 1800 6" (152.4) x 9" (228.6) x 6" (152.4) 21.5" (546.1) x 21" (533.4) x 17" (431.8) 110 (50)

0.65 Cu.Ft. (18.4 liters)


BF51794C Digital/OTP 208/240V, 50/60 Hz 3500 9" (228.6) x 14" (355.6) x 9" (228.6) 26" (660.4) x 25.75" (654.04) x 21" (533.4) 130 (59)
BF51894C Multiple Seg/1 Prog/OTP 208/240V, 50/60 Hz 3500 9" (228.6) x 14" (355.6) x 9" (228.6) 26" (660.4) x 25.75" (654.04) x 21" (533.4) 130 (59)

1.5 Cu.Ft. (42.5 liters)


BF51728C Digital/OTP 208/240V, 50/60 Hz 5600 12" (304.8) x 18" (457.2) x 12" (304.8) 28" (711.2) x 30" (762) x 24" (609.6) 185 (84)
BF51828C Multiple Seg/1 Prog/OTP 208/240V, 50/60 Hz 5600 12" (304.8) x 18" (457.2) x 12" (304.8) 28" (711.2) x 30" (762) x 24" (609.6) 185 (84)
Note: All models include 10' power cord except 1.5 cu. ft. models which require customer supplied power cord or hard
wiring. Contact your sales representative for CE Models.
Note: Use with inert atmosphere will exhibit some leakage.

HEAT-UP/COOL-DOWN HEAT-UP/COOL-DOWN
Model BF51848ANo load Model BF51894CNo load
1100 1100
1000 1000
900 900
800 800
Degrees Centigrade
Degrees Centigrade

700 700
600 600
500 500
400 400
300 300
200 200
100 100
0 0
0 5 10 15 20 25
30 35 40 45 50 55 60 0 5 10 15 20 25
30 35 40 45 50 55 60
Minutes Minutes
Heat-Up Cool-Down Heat-Up Cool-Down
39% holding power @1100C 39% holding power @ 1100C
Chamber uniformity @1100C 2C over back two-thirds of heated chamber length. Chamber uniformity @1100C 2C over back two-thirds of heated chamber length.

Model BF51848A Model BF51894C


Heat-Up/Cool-Down, No Load Heat-Up/Cool-Down, No Load

Actual performance may vary depending on load, chamber size, sample placement, ambient temperature and environmental conditions.


800-252-7100 www.lindbergbluem.com

Box Furnaces
Phone:886-2-2767-3510 Http://www.sjcom.com.tw

Model BF51842C
1200C LGO Box
Furnace with
multiple segment, sin-
gle program controller
integrated into the
main control panel.
(below)

Applications
Drying
Ashing
Annealing
Enameling
Tempering
Heat treating
Model BF51732BC, 1200C LGO Box Furnace
features digital control and OTC system. Melting

1200C LGO Box Furnaces


Versatile LGO Series Box Furnaces feature Platinel II thermocouple for long-term Digital Single Program, Multiple
6 the latest technical advances in heating stability Segment, Programmable Controller
elements, insulation and temperature Main power on/off switch on control Microprocessor-based self-tuning PID
control, all integrated into a self-contained panel; control panel designed for easy control (proportional, integral, deriva-
cabinet.The patented LGO heating maintenance access tive) provides optimum thermal process,
element (light gauge overbend) delivers prevents overshoot
maximum radiant heat energy to the Safety door switch to interrupt power to
process load. The LGO element is partially heating element when door is opened; Single program with multiple segments
imbedded within the exclusive protects heating elements and minimizes for ramp (up and down) and dwell
Moldatherm insulation, combined with exposure to end-user (timed hold) temperature control. See
unique double shell construction to pro- Removable shelves for versatility; 0.58 page 35 for more information
vide optimum temperature uniformity, cu.ft. models include 1 two-part shelf, Adjustable high limit overtemperature
energy efficiency, fast response, quick heat- center position; 1.95 cu.ft. models have protection
up and rapid cool-down. 3 shelf positions; 1 two-part shelf Simultaneous LED display of actual
included standard temperature vs. setpoint
Features and Benefits Moldatherm hearthplate supports load May be configured to display
Patented LGO (light gauge overbend) and prevents damage due to spillage temperature in either C or F
heating elements with Moldatherm
insulation for efficient and economical Digital, Single Setpoint Controller Digital Multiple Program, Multiple
transfer of heat to chamber, with low Microprocessor-based self-tuning PID Segment Programmable Controller
exterior temperatures control (proportional, integral, Available on models with P designation
Variable heat-up rate eliminates thermal derivative) provides optimum thermal Microprocessor-based self-tuning PID
shock to materials with quick heat-up process, prevents overshoot control (proportional, integral, deriva-
and cool-down rates Single segment, single setpoint, 1 ramp tive) provides optimum thermal process,
Choice of side hinge or vertical lift to setpoint prevents overshoot
door; see specifications for model Adjustable high limit overtemperature Multiple programs and segments for
selection protection ramp (up and down) and dwell (timed
Air vent (1" dia., top) and air inlet Simultaneous LED display of actual hold) temperature control. See page 35
(.375" dia., rear) for inert atmosphere temperature vs. setpoint for more information
exchange. May experience some leakage Adjustable high limit overtemperature
May be configured to display
at door protection
temperature in either C or F
Self-tuning, digital instrumentation for Simultaneous LED display of actual
precise temperature setpoint and temperature vs. setpoint
display
May be configured to display
temperature in either C or F


800-252-7100 www.lindbergbluem.com
Phone:886-2-2767-3510 Http://www.sjcom.com.tw

1200C LGO Box Furnaces

Vertical Lift Door, 0.6 cu ft (16.4 liters),Temperature Range 100C to 1200C


Furnace Integrated Electrical Watts Interior Dimensions Exterior Dimensions Ship Weight
Model No. Digital Control Volts, Hz, 1 H x F-B x W in" (mm) H* x F-B x W in" (mm) lbs (kg)
Single Setpoint
BF51731C Digital 208/240V, 50/60 Hz 4500 7" (177.8) x 11" (279.4) x 13" (330.2) 27" (685.8) x 23" (584.2) x 24" (609.6) 165 (75)
BF51731BC Digital/OTC 208/240V, 50/60 Hz 4500 7" (177.8) x 11" (279.4) x 13" (330.2) 27" (685.8) x 23" (584.2) x 24" (609.6) 165 (75)
Programmable, Single Program
BF51732C Multi Seg/1 Prog 208/240V, 50/60 Hz 4500 7" (177.8) x 11" (279.4) x 13" (330.2) 27" (685.8) x 23" (584.2) x 24" (609.6) 165 (75)
BF51732BC Multi Seg/1 Prog/OTC 208/240V, 50/60 Hz 4500 7" (177.8) x 11" (279.4) x 13" (330.2) 27" (685.8) x 23" (584.2) x 24" (609.6) 165 (75)
Programmable, Multiple Program
BF51732PC Multi Seg/Multi Prog 208/240V, 50/60 Hz 4500 7" (177.8) x 11" (279.4) x 13" (330.2) 27" (685.8) x 23" (584.2) x 24" (609.6) 165 (75)
BF51732PBC Multi Seg/Multi Prog/OTC 208/240V, 50/60 Hz 4500 7" (177.8) x 11" (279.4) x 13" (330.2) 27" (685.8) x 23" (584.2) x 24" (609.6) 165 (75)
BF51732PFMC Multi Seg/Multi Prog/FM 208/240V, 50/60 Hz 4500 7" (177.8) x 11" (279.4) x 13" (330.2) 27" (685.8) x 23" (584.2) x 24" (609.6) 165 (75)
BF51732PBFMC Multi Seg/Multi Prog/OTC/FM 208/240V, 50/60 Hz 4500 7" (177.8) x 11" (279.4) x 13" (330.2) 27" (685.8) x 23" (584.2) x 24" (609.6) 165 (75)
Note: Required power cord and hardwiring are not included.
* Overall height with door open is 39" on vertical lift door models only.

Horizontal Side Swing Door, 2.0 cu.ft. (55.3 liters),Temperature Range 100C to 1200C
Single Setpoint
BF51841C Digital 208/240V, 50/60 Hz 5800 15" (381) x 15" (381) x 15" (381) 33" (838.2) x 28" (711.2) x 29" (736.6) 280 (127)
BF51841BC Digital/OTC 208/240V, 50/60 Hz 5800 15" (381) x 15" (381) x 15" (381) 33" (838.2) x 28" (711.2) x 29" (736.6) 280 (127)
Programmable, Single Program
BF51842C Multi Seg/1 Prog 208/240V, 50/60 Hz 5800 15" (381) x 15" (381) x 15" (381) 33" (838.2) x 28" (711.2) x 29" (736.6) 280 (127)
BF51842BC Multi Seg/1 Prog/OTC 208/240V, 50/60 Hz 5800 15" (381) x 15" (381) x 15" (381) 33" (838.2) x 28" (711.2) x 29" (736.6) 280 (127)
Programmable, Multiple Program 7
BF51842PC Multi Seg/Multi Prog 208/240V, 50/60 Hz 5800 15" (381) x 15" (381) x 15" (381) 33" (838.2) x 28" (711.2) x 29" (736.6) 280 (127)
BF51842PBC Multi Seg/Multi Prog/OTC 208/240V, 50/60 Hz 5800 15" (381) x 15" (381) x 15" (381) 33" (838.2) x 28" (711.2) x 29" (736.6) 280 (127)
BF51842PFMC Multi Seg/Multi Prog/FM 208/240V, 50/60 Hz 5800 15" (381) x 15" (381) x 15" (381) 33" (838.2) x 28" (711.2) x 29" (736.6) 280 (127)
BF51842PBFMC Multi Seg/Multi Prog/OTC/FM 208/240V, 50/60 Hz 5800 15" (381) x 15" (381) x 15" (381) 33" (838.2) x 28" (711.2) x 29" (736.6) 280 (127)
Note: Required power cord and hardwiring are not included.

Overtemperature Control (OTC) Optional RS485 Digital Gas flowmeter, adjustable, located on
Adjustable digital overtemperature Communications Port front control panel
control, available on selected RS485 Digital Communications port avail- Adjustable flow rate, range 1.0 to 10.0
models with B suffix designation; able as an option. Allows controller to cu.ft./hr standard
see chart be connected to a PC for remote moni-
Suitable for inert gas or air flow to
toring and control of the furnace. Up to
Protects furnace and load in the event of chamber
30 units can be connected to one PC.
primary control circuit failure Please see page 35 for ordering Allows fresh air exchange for ashing
Overrides main controller and shuts off information and additional options applications
power to furnace if high limit is reached Not suitable for combustible or volatile
Manual re-set required for safety Flowmeter Option (FM) gases
(Inert Atmosphere Only)
Operates via magnetic contacts through Note: Use with inert atmosphere will
signal from independent thermocouple Available on selected models with FM
designation; see chart exhibit some leakage.

HEAT-UP/COOL-DOWN
Model BF51732CNo load
1200
Degrees Centigrade

1000
800
600
400 Model BF51732C,
200 Heat-Up/Cool-
0
Heat-up (Min) 0 5 10 15 20 25
Down, No Load
Cool-down (Hrs) 0 0.5 1 1.5 2 2.5 3 3.5 4
Heat-up time Cool-down time
37% holding power @ 1200C
Chamber uniformity @1200C 2%C over back two-thirds of heated chamber length.

Actual performance may vary depending on load, chamber size, sample placement, ambient temperature and environmental conditions.


800-252-7100 www.lindbergbluem.com

Box Furnaces
Phone:886-2-2767-3510 Http://www.sjcom.com.tw

Applications
Ashing
Fusion
Ignitions
Alloying
Sintering
Model BF51442C requires the 1200C, CC58114C
controller (below) ordered separately. Heat-treating

1200C Box Furnaces, Heavy-Duty


Heavy-Duty 1200C Box Furnaces feature Helically coiled, high temperature alloy Refractory plate heating unit (Model
8 a unique internal construction and outer wire elements for extended service life BF51442C)
shell design which reduces external surface Unique Moldatherm ceramic fiber Heating element imbedded in
temperatures without compromising insulation to allow rapid heat-up, Moldatherm insulation (Model
interior temperature uniformity. Requires recovery and cool-down rates BF51542C)
independent control console, Model No.
CC58114C (ordered separately). High temperature insulation in vestibule Rugged, heavy-duty Inconel hearthplate
and floating plug door to minimize heat supports load and protects the furnace
loss and improve temperature control from damage due to spillage (Model
Features BF51542C)
Spring-loaded door holds door securely
Individual heating elements at chamber shut; door rests in horizontal position Long-life Platinel II thermocouple with
top, bottom and sides for uniform heat when open 10' compensated lead wire and
distribution polarized plug
Sight glass for convenient observation of
Swing down door provides convenient heated load during operation
loading platform.

The Model CC58114C Controller can be positioned adja-


cent to or remote from the furnace, permitting applica-
tions in fume hoods or containment areas.



800-252-7100 www.lindbergbluem.com
Phone:886-2-2767-3510 Http://www.sjcom.com.tw

1200C Box Furnace, Heavy Duty


With Refractory Plate Heating Element, Temperature Range 100 to 1200C
Furnace Independent Electrical Watts Interior Dimensions, Furnace Exterior Dimensions, Furnace Ship Weight
Model No. Controller Volts, Hz, 1 H x F-B x W in" (mm) H x F-B x W in" (mm) lbs (kg)
BF51442C CC58114C 208/240V, 50/60 Hz 4800 5.25" (133.35) x 14" (355.6) x 7.5" (190.5) 24.5" (622.3) x 20" (508) x 20" (508) 145 (66)

With Moldatherm Heating Element (Four Sides), Temperature Range 100 to 1200C
BF51542C CC58114C 208/240V, 50/60 Hz 6200 9.5" (241.3) x 14.5" (368.3) x 10.5" (266.7) 28.5" (723.9) x 31" (787.4) x 28" (711.2) 335 (152)
Note: Required power cord, hardwiring and interconnecting wiring are not included.

1200C Digital, Single Setpoint advanced microprocessor-based digital con- Protects furnace and load in the event of
Controller trol, a solid-state power module, on/off cir- primary control circuit failure. Overrides
Control console is fully wired and includes cuit breaker and thermocouple input jack. main controller and shuts off power to fur-
advanced microprocessor-based digital con- Includes microprocessor-based PID control nace if high limit is reached. Manual re-set
trol, a solid-state power module, on/off cir- (proportional, integral, derivative), with sin- required for safety. Operates via magnetic
cuit breaker and thermocouple input jack. gle program with multiple segments for contacts through signal from independent
Includes microprocessor-based PID control ramp (up and down) and dwell (timed thermocouple.
(proportional, integral, derivative), single hold) temperature control. See page 35 for
more information. Built-in adjustable high
Optional RS485 Digital
segment, single setpoint, 1 ramp to setpoint. Communications Port
Built-in adjustable high limit overtempera- limit overtemperature protection.
Simultaneous LED display of actual tempera- RS485 Digital communications port avail-
ture protection. Simultaneous LED display of able as an option. Allows controller to be
actual temperature vs. setpoint. May be ture vs. setpoint. May be configured to dis-
play temperature in either C or F. connected to a PC for remote monitoring
configured to display temperature in either and control of the furnace. Up to 30 units
C or F. can be connected to one PC. Please see
Option B Overtemperature
Option P 1200C Digital Single Control (OTC) page 35 for ordering information and addi-
Program, Multiple Segment Adjustable digital overtemperature control, tional options.
Programmable Controller factory installed on selected control con-
Control console is fully wired and includes soles with B suffix designation; see chart.

Controller Digital With With Electrical Maximum Exterior Dimensions Ship Weight
Model No. Programmer Overtemp Volts, Hz Amps H x F-B x W in" (mm) lbs (kg) 9
Control
CC58114C 208/240V, 50/60Hz 30 10" (254) x 19" (482.6) x 14" (355.6) 40 (18)
CC58114PC 208/240V, 50/60Hz 30 10" (254) x 19" (482.6) x 14" (355.6) 40 (18)
With Overtemp Control
CC58114BC 208/240V, 50/60Hz 30 10" (254) x 19" (482.6) x 14" (355.6) 40 (18)
CC58114PBC 208/240V, 50/60Hz 30 10" (254) x 19" (482.6) x 14" (355.6) 40 (18)
Note: Required power cord, hardwiring and interconnecting wiring are not included.

HEAT-UP/COOL-DOWN
Model BF51442CNo load
Degrees Centigrade

1200
1000
800
600
400
200
0
0 1 2 3 4 5 6 7
Heat-up time (Hours) Cool-down (Hours)
38% holding power @ 1200C

Chamber uniformity @1200C 5C nominal.

Model BF51442C, Heat-Up/Cool-Down, No Load

Actual performance may vary depending on load, chamber size, sample placement, ambient temperature and environmental conditions.


800-252-7100 www.lindbergbluem.com

Box Furnaces
Phone:886-2-2767-3510 Http://www.sjcom.com.tw

Below, Model
BF51643C Box
Furnace,
1500C, with
side swing
door

Applications
Ashing
Fusion
Ignitions
Alloying
Above, Model BF51433PBC Box Furnace,
1500C, with vertical lift door, shown with Sintering
multiple segment integrated digital pro-
grammable controller.

1500C Box Furnaces, Multi-Purpose,


Integral Control
Features for ramp (up and down) and dwell Option B Overtemperature
Double-wall construction with (timed hold) temperature control. See Control (OTC)
Moldatherm insulation for rapid heat- page 35 for more information Adjustable digital overtemperature
up and cool-down, energy efficiency and Adjustable high limit overtemperature control, protects furnace and load in the
cooler exterior surface temperatures protection. Simultaneous LED display of event of primary control circuit failure
10 actual temperature vs. setpoint in either available on selected models with B
Silicon carbide heating elements for
long-life, safety and reliable service with C or F suffix designation; see chart
maximum energy savings Digital Multiple Program, Multiple Overrides main controller and shuts off
Safety door switch interrupts power to Segment Programmable Controller power to furnace if high limit is reached
heating elements when door is opened; Microprocessor-based PID control, Manual re-set required for safety
protects elements and minimizes multiple programs and segments for Operates via magnetic contacts through
exposure to operator ramp (up and down) and dwell (timed signal from independent thermocouple
Moldatherm hearthplate supports hold) temperature control. See page 35
load and protects interior from spillage for more information Optional RS485 Digital
and mishandling Adjustable high limit overtemperature
Communications Port
protection RS485 Digital communications port
Type R Thermocouple is integrated
into chamber backwall available as an option. Allows controller
Simultaneous digital LED display of
to be connected to a PC for remote
actual temperature vs. setpoint in either
Digital Single Program, Multiple monitoring and control of the furnace.
C or F
Segment Programmable Controller Up to 30 units can be connected to one
Microprocessor-based PID control, PC. Please see page 35 for ordering
single program with multiple segments information and additional options

1500C Box Furnaces


Vertical Lift Door, Temperature Range 500C to 1500C
Furnace Integrated Electrical Watts Door Interior Dimensions Exterior Dimensions Ship Weight
Model No. Digital Control Volts, Hz, 1 H x F-B x W in" (mm) H x F-B x W in" (mm) lbs (kg)
BF51433C Multi Seg/1 Prog 208/240V, 50/60 Hz 6400 Vertical Lift 5" (127) x 12" (304.8) x 6" (152.4) 26" (660.4) x 29" (736.6) x 25" (635) 320 (145)
BF51433BC Multi Seg/1 Prog/OTC 208/240V, 50/60 Hz 6400 Vertical Lift 5" (127) x 12" (304.8) x 6" (152.4) 26" (660.4) x 29" (736.6) x 25" (635) 320 (145)
BF51433PC Multi Seg/Multi Prog 208/240V, 50/60 Hz 6400 Vertical Lift 5" (127) x 12" (304.8) x 6" (152.4) 26" (660.4) x 29" (736.6) x 25" (635) 320 (145)
BF51433PBC Multi Seg/Multi Prog/OTC 208/240V, 50/60 Hz 6400 Vertical Lift 5" (127) x 12" (304.8) x 6" (152.4) 26" (660.4) x 29" (736.6) x 25" (635) 320 (145)
Side Swing Door, Temperature Range 500C to 1500C
BF51643C Multi Seg/Multi Prog 208/240V, 50/60 Hz 14800 Side Swing 9" (228.6) x 15.5" (393.7) x 11" (279.4) 31" (787.4) x 30" (762) x 28" (711.2) 320 (145)
BF51643BC Multi Seg/Multi Prog/OTC 208/240V, 50/60 Hz 14800 Side Swing 9" (228.6) x 15.5" (393.7) x 11" (279.4) 31" (787.4) x 30" (762) x 28" (711.2) 320 (145)
Note: Required power cord and hardwiring are not included.


800-252-7100 www.lindbergbluem.com

Box Furnaces
Phone:886-2-2767-3510 Http://www.sjcom.com.tw

Model BF51333C
Box Furnace is
constructed with
rugged firebrick
insulation for
stability, silicon
carbide heating
elements to
maximize heat
transfer, insulat-
ing door plug
and swing-down
door for conve-
nience and safety

Applications
Annealing
Melting
Heat Treating
Brazing
Left, Model CC58125C Controller, Alloying
ordered separately.

1500C Box Furnace, Independent Control


1500C Box Furnace, Brick Sidewall Composition, Temperature Range 500C to 1500C
Furnace Independent Electrical Watts Interior Dimensions Exterior Dimensions Ship Weight
Model No. Controller Volts, Hz, 1 H x F-B x W in" (mm) H x F-B x W in" (mm) lbs (kg) 11
BF51333C CC58125C 208/240V, 50/60 Hz 5900 5" (127) x 12" (304.8) x 6" (152.4) 26" (660.4) x 29" (736.6) x 25" (635) 440 (200)
Note: Required power cord, hardwiring and interconnecting wiring are not included. Silicon-carbide heating elements. Fitted hearthplate protects inte-
rior from spills.Type R thermocouple integrated into chamber backwall, top. Includes 10' compensated thermocouple lead wire and polarized plug.

1500C Digital, Single Setpoint processor-based digital control, a solid-state Protects furnace and load in the event of
Controller power module, on/off circuit breaker and primary control circuit failure. Overrides
Control console is fully wired and includes thermocouple input jack. Includes micro- main controller, assumes temperature con-
advanced microprocessor-based digital processor-based PID control (proportional, trol and shuts off power to furnace if high
control, a solid-state power module, on/off integral, derivative), single program with limit is reached. Manual re-set required for
circuit breaker and thermocouple input multiple segments for ramp (up and down) safety. Operates via magnetic contacts
jack. Includes microprocessor-based PID and dwell (timed hold) temperature con- through signal from independent thermo-
control (proportional, integral, derivative), trol. See Page 35 for more information. couple.
single segment, single setpoint, 1 ramp to Built-in adjustable high limit overtempera-
ture protection. Simultaneous LED display Optional RS485 Digital
setpoint. Built-in adjustable high limit
of actual temperature vs. setpoint. May be Communications Port
overtemperature protection. Simultaneous
LED display of actual temperature vs. set- configured to display temperature in either RS485 Digital communications port avail-
point. May be configured to display tem- C or F. able as an option. Allows controller to be
perature in either C or F. connected to a PC for remote monitoring
Option B Overtemperature and control of the furnace. Up to 30 units
Option P 1500C Digital Single Control (OTC) can be connected to one PC. Please see
Program, Multiple Segment Adjustable digital overtemperature control, page 35 for ordering information and addi-
Programmable Controller factory installed on selected control con- tional options.
Control console includes advanced micro- soles with B suffix designation; see chart.

Controller Digital With With Electrical Maximum Exterior Dimensions Ship Weight
Model No. Programmer Overtemp Volts, Hz Amps H x F-B x W in" (mm) lbs (kg)
Control
CC58125C 208/240V, 50/60Hz 60 10" (254) x 19" (482.6) x 14" (355.6) 35 (16)
CC58125BC 208/240V, 50/60Hz 60 10" (254) x 19" (482.6) x 14" (355.6) 35 (16)
CC58125PC 208/240V, 50/60Hz 60 10" (254) x 19" (482.6) x 14" (355.6) 35 (16)
CC58125PBC 208/240V, 50/60Hz 60 10" (254) x 19" (482.6) x 14" (355.6) 35 (16)


800-252-7100 www.lindbergbluem.com

Box Furnaces
Phone:886-2-2767-3510 Http://www.sjcom.com.tw

Applications
Sintering,
Ashing
Bonding
Melting
Metals and
The BF51314C, 1700C Box Furnace requires an ceramic
independent controller, Model CC59246PCOMC, for composites
programmable operation.

1700C Box Furnaces, Independent Control


Research and Pilot Plant Production Moldatherm high temperature Long-life type B thermocouples
12 The General Purpose 1700C Box Furnace ceramic fiber insulation with advanced with 10' compensated lead wire and
with independent control are designed graded design for fast heat-up and polarized plug for accurate high
for applications which require extremely resistance to thermal shock temperature measurement
rapid heat-up rates, with 3500 watt Vertically hinged door lifts up and out of
models reaching 1700C in as little as 15 the way to save space and minimize Smart Heating Elements
minutes. Choose from two popular exposure to the operator Molybdenum disilicide elements with
chamber sizes, each with a fully program- Removable panels for easy access to unique right angle bend and sidewall
mable independent controller (ordered replaceable heating elements and mounting reduce maintenance usually
separately, see chart). thermocouples associated with element termination and
mounting
Moldatherm hearthplate supports
Features Designed for easy replacement without
load and protects chamber from spills
Available in two popular chamber sizes or mishandling matching resistance values
(see chart) Fast heat-up and recovery with excellent
High volume cooling fans move air
Double shell design for lower external between inner and outer chamber to uniformity and energy efficiency
cabinet temperature with energy savings reduce exterior shell temperatures and Increased resistance to thermal shock,
improve energy efficiency and operator ideal for rapid cycling over extended
safety periods

Moldatherm high
temperature ceramic
Programmable fiber insulation with
Controller, advanced graduated
1700C Model density composition
CC59256PCOMC. for fast heat-up and
resistance to thermal
shock.
Moldatherm Graduated
Density Insulation



800-252-7100 www.lindbergbluem.com
Phone:886-2-2767-3510 Http://www.sjcom.com.tw

1700C Box Furnaces, Temperature Range 500C to 1700C

Furnace Independent Electrical Watts Interior Dimensions Exterior Dimensions Ship Weight
Model No. Controller Volts, Hz, 1 H x F-B x W in" (mm) H x F-B x W in" (mm) lbs (kg)
BF51314C CC59246PCOMC 208/240V, 50/60 Hz 3500 5" (127) x 6" (152.4) x 5" (127) 14" (355.6) x 16" (406.4) x 16" (406.4) 85 (39)
BF51524C CC59256PCOMC 208/240V, 50/60 Hz 5000 6.5" (165.1) x 10" (254) x 8.5" (215.9) 15.75" (400.05) x 19.5" (495.3) x 19.5" (495.3) 115 (53)

1700C Controller, Programmable, settings for the thermal process. LED dis- Option B Overtemperature
With Communications play indicates actual temperature. High Control (OTC)
Lindberg/Blue M 1700C Programmable limit overtemperature protection is stan- Adjustable digital overtemperature
Controllers provide multiple programs and dard.The control console includes a circuit control, factory installed on selected
multiple segments for ramp (up and down) breaker, power module, transformer and control consoles with B suffix designa-
and dwell (timed hold) temperature con- cooling fans. tion; see chart. Protects furnace and load in
trol.The controller visually displays ramp Controllers include RS485 data port (com- the event of primary control circuit failure.
rate, dwell time, program segment and per- munications card and port) for connection Overrides main controller and shuts off
cent power output. A holdback feature to remote computer, allowing modification, power to furnace if high limit is reached.
allows the operator to set a process vs set- interrogation and data transfer of all instru- Manual re-set required for safety. Operates
point temperature value which, when ment control and configuration parameter. via signal from independent thermocouple.
exceeded, holds the program to allow the Up to 30 units can be connected to one
process to catch up. Please see page 35 for PC. Software is not included, but is avail-
additional information. able as an option. Please see page 35 for
The controller includes a selectable additional options and information.
self-tuning feature which sets the best PID

Controller Digital With With Electrical Exterior Dimensions Ship Weight


Model No. Programmer Overtemp Volts, Hz H x F-B x W in" (mm) lbs (kg)
Controller
CC59246PCOMC 208/240V, 50/60Hz 10" (254) x 15" (381) x 21" (533.4) 115 (53)
CC59246PBCOMC 208/240V, 50/60Hz 10" (254) x 15" (381) x 21" (533.4) 115 (53)
CC59256PCOMC 208/240V, 50/60Hz 10" (254) x 15" (381) x 21" (533.4) 130 (59)
CC59256PBCOMC 208/240V, 50/60Hz 10" (254) x 15" (381) x 21" (533.4) 130 (59)
13
Note: Required power cord, hardwiring and interconnecting wiring are not included.

Heat-Up/Cool-Down
Model BF51314CNo load
1800
1600
1400
Degrees Centigrade

1200
1000
800
600
400
200
0
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Minutes
Heat-Up Cool-Down
42% holding power @ 1700C.
Chamber uniformity @1700C 3%C nominal.

Model BF51314C Heat-Up/Cool-Down, No Load.

Actual performance may vary depending on load, chamber size, sample placement, ambient temperature and environmental conditions.



800-252-7100 www.lindbergbluem.com

Box Furnaces
Phone:886-2-2767-3510 Http://www.sjcom.com.tw

Applications
Sintering,
Ashing
Bonding
Melting
Metals and
Integrated controls are standard on the large chamber, ceramic
1700C Box Furnaces. Models available in 0.6 and 0.9 composites
cu.ft. capacities. Model BF51634C shown.

1700C Box Furnaces,Large Chamber,


Integral Control
Large Chamber 1700C Box Furnaces are Removable panels for easy access to Energy efficient, fast heat-up and response
14 designed for efficient, high temperature use replaceable heating elements and Increased resistance to thermal shock,
with minimal maintenance. thermocouples ideal for rapid cycling over extended
Atmosphere port, .375" diameter, for periods
Moldatherm graduated density insulation fresh air or inert gas inlet (located at Designed for easy replacement without
adds to safety and performance by forming back wall, bottom)
enhanced insulation protection between matching resistance values
Moldatherm hearthplate supports load
the high temperature chamber and exterior
cabinet surface. Unique right angle heating and protects chamber from damage due
elements and an integrated control system to spillage
(a choice of single setpoint or programma- High volume cooling fans move air
ble control) combine to deliver safe, between inner and outer chamber to
dependable operation. lower exterior shell temperatures and
improve energy efficiency
Solid-state power module with ammeter,
Construction
circuit breaker, transformer and front
Available in two popular chamber sizes panel indicator lights for Ready
(see chart) Element and Main Power
Energy efficient double shell design for Applied
better uniformity, lower external cabinet Long-life type B thermocouples for
temperature accurate high temperature measurement Moldatherm Graduated
Moldatherm high temperature ceramic Density Insulation
Safety power disconnect switch cuts
fiber insulation with advanced graded power to heating elements when door is
design for fast heat-up and resistance to opened
thermal shock Moldatherm high temperature ceramic
fiber insulation with advanced graduat-
Side swing door provides full and easy ed density composition for fast heat-up
access to chamber, protects user from Smart Heating Elements
and resistance to thermal shock
heat surge Molybdenum disilicide elements with
unique right angle bend and sidewall
mounting to reduce maintenance
associated with element termination and
mounting



800-252-7100 www.lindbergbluem.com
Phone:886-2-2767-3510 Http://www.sjcom.com.tw

Digital, Single Setpoint Controller LED display of actual temperature Option B Overtemperature
Microprocessor-based PID control May be configured to display tempera- Control (OTC)
(proportional, integral, derivative) ture in either C or F Adjustable digital overtemperature
prevents overshoot control, available on selected models
Programmable Control With with B suffix designation; see chart
Single segment, single setpoint, 1 ramp Communications
to setpoint Protects furnace and load in the event of
Available on COM Models
Adjustable high limit overtemperature primary control circuit failure
protection Controllers include RS485 data port Overrides main controller and shuts off
(communications card and port) for power to furnace if high limit is reached
Simultaneous LED display of actual connection to remote computer,
temperature vs. setpoint allowing modification, interrogation and Manual re-set required for safety
May be configured to display tempera- data transfer of all instrument control Operates via magnetic contacts through
ture in either C or F and configuration parameter. Up to 30 signal from independent thermocouple
units can be connected to one PC. Factory installed, specify when ordering
Option P Digital Multiple Program, Software is not included, but is available
Multiple Segment Programmable as an option. Please see page 35 for
Controller additional options and information.
Microprocessor-based PID control Includes installed communications card
(proportional, integral, derivative) and port for user connection
prevents overshoot
Multiple programs and segments for
ramp (up and down) and dwell (timed
hold) temperature control. See page 35
for more information

1700C Box Furnaces, Large Chamber, Temperature Range 500C to 1700C


For Overtemperature Control Specify Option B When Ordering.
Furnace Integrated Electrical Watts Interior Dimensions Exterior Dimensions Ship Weight
Model No. Digital Control Volts, Hz, 1 H x F-B x W in" (mm) H x F-B x W in" (mm) lbs (kg)
Capacity 0.6 cu.ft. (17 liters)
BF51634C Digital/1 setpoint 208/240V, 50/60 Hz 5900 9" (228.6) x 10.5" (266.7) x 11" (279.4) 31" (787.4) x 24" (609.6) x 28" (711.2) 350 (159)
BF51634PC Multi Seg/Multi Prog 208/240V, 50/60 Hz 5900 9" (228.6) x 10.5" (266.7) x 11" (279.4) 31" (787.4) x 24" (609.6) x 28" (711.2) 350 (159)
BF51634PCOMC Multi Seg/Multi Prog/Com 208/240V, 50/60 Hz 5900 9" (228.6) x 10.5" (266.7) x 11" (279.4) 31" (787.4) x 24" (609.6) x 28" (711.2) 350 (159) 15
Capacity 0.9 cu.ft. (25.5 liters)
BF51664C Digital/1 setpoint 208/240V, 50/60 Hz 7100 9" (228.6) x 15.5" (393.7) x 11" (279.4) 31" (787.4) x 30" (762) x 28" (711.2) 370 (168)
BF51664PC Multi Seg/Multi Prog 208/240V, 50/60 Hz 7100 9" (228.6) x 15.5" (393.7) x 11" (279.4) 31" (787.4) x 30" (762) x 28" (711.2) 370 (168)
BF51664PCOMC Multi Seg/Multi Prog/Com 208/240V, 50/60 Hz 7100 9" (228.6) x 15.5" (393.7) x 11" (279.4) 31" (787.4) x 30" (762) x 28" (711.2) 370 (168)
Note: Required power cord and hardwiring are not included.

Heat-Up/Cool-Down
Model BF51634C
1800
1600
1400
Degrees Centigrade

1200
1000
800
600
400
200
0
0 10 20 30 40 50 60 70 80 90 100 110 120
Minutes
Heat-Up Cool-Down
Chamber uniformity @1700C 2%C nominal.

Model BF51634C Heat-Up/Cool-Down, No load

Actual performance may vary depending on load, chamber size, sample placement, ambient temperature and environmental conditions.


800-252-7100 www.lindbergbluem.com

Tube Furnaces
Phone:886-2-2767-3510 Http://www.sjcom.com.tw

Applications
Pyrolysis
Thermal Expansion
Calibration
Sintering
The 1100C Mini-Mite Tube Furnace includes
integrated digital control, single setpoint or Viscosity Testing
multiple segment programmable.

16 Mini-Mite 1100C Tube Furnaces


(Single Zone)
Mini-Mite 1100C Tube Furnaces offer a Digital, Single Setpoint Single program with multiple segments
selection of control instrumentation Controller for ramp (up and down) and dwell
including multiple segment programmable Microprocessor-based self-tuning PID (timed hold) temperature control. See
or single setpoint control. All models control (proportional, integral, page 35 for more information
feature energy efficient Moldatherm derivative) provides optimum thermal Adjustable high limit overtemperature
insulation for quick heat-up and cool- process without overshoot protection
down.
Single segment, single setpoint, 1 ramp Simultaneous LED display of actual
to setpoint temperature vs. setpoint
Features Adjustable high limit overtemperature May be configured to display
Compact, portable and lightweight protection temperature in either C or F
design Simultaneous LED display of actual
Split-hinge design simplifies loading and temperature vs. setpoint Optional RS485 Digital
unloading May be configured to display Communications Port
Main power on/off switch on temperature in either C or F RS485 Digital communications port
control panel available as an option. Allows controller
Safety switch disconnects power to Digital Single Program, Multiple to be connected to a PC for remote
heating element when furnace is Segment Programmable Controller monitoring and control of the furnace.
opened Up to 30 units can be connected to one
Microprocessor-based self-tuning PID PC. Please see page 35 for ordering
Long life type K thermocouple control (proportional, integral, information and additional options
derivative) provides optimum thermal
process without overshoot



800-252-7100 www.lindbergbluem.com
Phone:886-2-2767-3510 Http://www.sjcom.com.tw

1100C Mini-Mite Split-Hinge, Single Zone, Integrated Controller, Temperature Range 100 to 1100C

Furnace Electrical Watts Integral Exterior Dimensions *Process Tube Heated Length Ship Weight
Model No. Volts, Hz, 1 Controller H x F-B x W in" (mm) Diameter, in" (mm) in" (mm) lbs (kg)

Digital, Single Segment Control, 1100C


TF55030A 120V, 50/60 Hz 800 1 Segment 15" (381) x 11" (279.4) x 16" (406.4) 1" (25.4) 12" (304.8) 35 (16)
TF55030C 208/240V, 50/60 Hz 800 1 Segment 15" (381) x 11" (279.4) x 16" (406.4) 1" (25.4) 12" (304.8) 35 (16)

Digital, Multi Segment Programmable, 1100C


TF55035A 120V, 50/60 Hz 800 16 Segment 15" (381) x 11" (279.4) x 16" (406.4) 1" (25.4) 12" (304.8) 35 (16)
TF55035C 208/240V, 50/60 Hz 800 16 Segment 15" (381) x 11" (279.4) x 16" (406.4) 1" (25.4) 12" (304.8) 35 (16)

*Process Tubes These furnaces are designed for use with a variety of process tubes including alumina, mullite, quartz and metallic.
For information on process tubes contact your process tube supplier or call your Lindberg/Blue M sales representative.
Note: All models include 10' power cord.

TF 55035A UNIFORMITYNo load


1100
Centigrade

1090
1080 1C over 2.2"
1070 3C over 3.3"
1060
6 5 4 3 2 1 0 1 2 3 4 5 6
Heated Chamber (inches)
1" Dia. mullite process tube. Ends plugged 17

Model TF55035A Uniformity Profile, No Load Model TF55035A Mini-Mite Tube


Furnace, 1100C, shown with digital
multiple segment programmable control.

HEAT-UP/COOL-DOWN
Model TF55035A No Load
1200
1100
1000
Degrees Centigrade

800

600

400

200

0
Cool-down (Hrs) 0 1 2 3
Heat-up (Min) 5 10 15 20 25 30
Heat-up time Cool-down time
Heat and cool rates measured in center 1"OD process tube.
Ends of tube plugged with ceramic fiber.

Model TF55035A Heat-Up/Cool-Down

Actual performance may vary depending on load, chamber size, sample placement, ambient temperature and environmental conditions.


800-252-7100 www.lindbergbluem.com

Tube Furnaces
Phone:886-2-2767-3510 Http://www.sjcom.com.tw

Applications
Annealing
Model STF55346C, Solid Tube, Three-Zone Furnace includes three Crystal Growing
multiple segment programmable controllers, one for each zone.
Calibration
(Process tube shown, not included).
Heat Treating

18 1100C Tube Furnaces


(Three Zone)
Three Zone 1100C Tube Furnaces Microprocessor-based self-tuning
have new, energy efficient designs PID control (proportional, integral,
incorporating Lindberg/Blue M exclusive derivative) provides optimum thermal
Moldatherm ceramic fiber insulation. process without overshoot
Performance attributes include excellent Single program with multiple segments
temperature uniformity, fast heat-up and for ramp (up and down) and dwell
cool-down, and quick recovery with opti- (timed hold) temperature control. See
mum power consumption.The furnace page 35 for more information
includes three independent, programmable
Adjustable high limit overtemperature
controllers, one for each zone.
protection
Simultaneous LED display of actual
Features
temperature vs. setpoint
Innovative use of venting and
May be configured to display
Programmable control. Each insulating air spaces to create lower
exterior surface temperatures temperature in either C or F
zone programmable for variable
process requirements. Accepts an array of tube adapters
(see chart) Optional RS485 Digital
Communications Port
One set of (2) tube adapters included;
RS485 Digital communications port
standard, largest size supplied
available as an option. Allows controller
Flexible design, may be used for a to be connected to a PC for remote
variety of applications monitoring and control of the furnace.
Long-life Type K" thermocouples Up to 30 units can be connected to one
PC. Please see page 35 for ordering
Digital Single Program, Multiple information and additional options
Segment Programmable Controller
Three programmable controllers, one
for each zone



800-252-7100 www.lindbergbluem.com
Phone:886-2-2767-3510 Http://www.sjcom.com.tw

1100C Solid, Three Zone, Multi Segment Integrated Controller, Temperature Range 100C to 1100C
Furnace Electrical Watts Exterior Dimensions *Process Tube Heated Length Heated Zone Ship Weight
Model No. Volts, Hz, 1 H x F-B x W in" (mm) Diameter, in" (mm) in" (mm) in" (mm) lbs (kg)
STF55346C 208/240V, 50/60 Hz 3800 21" (533.4) x 17" (431.8) x 35" (889) 1" (25.4) to 3" (76.2) 24" (609.6) 6"/12"/6" (152.4/304.8/152.4) 225 (102)
STF55666C 208/240V, 50/60 Hz 11000 26" (660.4) x 22" (558.8) x 54" (1371.6) 3" (76.2) to 6" (152.4) 36" (914.4) 9"/18"/9" (228.6/457.2/228.6) 255 (115)
*Process Tubes These furnaces are designed for use with a variety of process tubes including alumina, mullite, quartz and metallic.
For information on process tubes contact your process tube supplier or call your Lindberg/Blue M sales representative.
One set of (2) Tube Adapters included with furnace; largest specified size supplied. See table for additional options.
Note: Required power cord and hardwiring are not included.

STF55346C Profile
1100 Tube FurnaceNo load
6" end zone 12" center zone 6" end zone
Degrees Centigrade

TC TC TC
+1

1 2 C span

Holding Power 50%


Tests peformed with 3" diameter process tube plugged with ceramic fiber.

Model STF55346C Uniformity Profile, 1100C Tube Furnace, No Load

19

Tube adapters prevent heat loss and Moldatherm Tube Adapters


improve temperature uniformity (each sold separately)
within the furnace chamber by
insulating the end vestibules. One set Model Model
(2) of tube adapters provided with Size STF55346C STF55666C
each Lindberg/Blue M furnace fits
the largest diameter process tube 1" 59541
specified for use with that furnace. 2" 59543
Interchangeable tube adapters which
3" 59545* 59555
allow alternative size process tubes
are available; see chart. 4" 59556
5" 59557
6" 59558*
Blank (Solid) 59549 59559
*One set of (2) included with furnace.

Actual performance may vary depending on load, chamber size, sample placement, ambient temperature and environmental conditions.


800-252-7100 www.lindbergbluem.com

Tube Furnaces
Phone:886-2-2767-3510 Http://www.sjcom.com.tw

Applications
Annealing
Crystal Growing
Calibration Model HTF55322C, 1200C Tube Furnace,
Heat Treating Split Hinge, Single Zone, adaptable for
vertical use. Shown right, Three-Zone tube
furnace Model HTF55347C (see page 22).

20
1200C Split-Hinge Tube Furnaces
The split-hinge design permits easy obser- Accepts interchangeable Moldatherm
vation, fast cooling, convenient placement tube adapters. See chart on page 23
of the process tube and overall ease of Long-life Platinel II thermocouple(s)
operation. All models can be used with a with 10' compensated lead wire and
variety of ceramic, quartz or alloy process polarized plug
tubes (customer supplied), diameters to 6"
depending on model. One set of tube
adapters is included with each model. Three Zone Models
Three independent power circuits
Features (zones) with independent
thermocouples for control references
Designed for horizontal or vertical
Full adjustment of each zone over entire
operation
operating range to 1200C
Patented Moldatherm LGO heating
Center zone uniformity achieved and
element modules for superior radial and
CC58434C Three Zone Controller linear temperature uniformity, fast heat- operating length maximized through
up and cool-down adjustable profiling of end zones by
independent controller
Single Zone and Three Zone Long-life, energy efficient elements
Temperature uniformity achieved with
Lindberg/Blue M 1200C split hinge tube require little or no maintenance
independent setpoint of end zones
furnaces are configurable for horizontal or Unique cabinet design achieves lower higher or lower than center
vertical use. Choose from single zone mod- exterior surface temperature
els of 12" and 24" heated lengths, and three Heat reflecting element support
zone models of 24" to 36" heated lengths. assembly creates two highly effective
Furnaces use independent digital temper- insulating air spaces
ature control modules (ordered separately)
Compact cabinet with high temperature
which are available in standard or program-
mable options. resistant painted finish



800-252-7100 www.lindbergbluem.com
Phone:886-2-2767-3510 Http://www.sjcom.com.tw

CC58114C Single Zone Controller Model HTF55322C 1200C Tube Furnace, Single Zone
(Process tube not included)

Single Zone
1200C Split Hinge, Horizontal or Vertical Use, Temperature Range 100C to 1200C

Furnace Electrical Watts Independent Exterior Dimensions *Process Tube Heated Length Ship Weight
Model No. Volts, Hz, 1 Controller H x F-B x W in" (mm) Diameter, in" (mm) in" (mm) lbs (kg)
HTF55122A 120V, 50/60 Hz 1330 CC58114A 12" (304.8) x 13" (330.2) x 21" (533.4) .75" (19.05) to 1" (25.4) 12" (304.8) 60 (28)
HTF55322A 120V, 50/60 Hz 2675 CC58114A 16" (406.4) x 17" (431.8) x 23" (584.2) 1" (25.4) to 3" (76.2) 12" (304.8) 120 (55)
HTF55322C 208/240V, 50/60 Hz 2675 CC58114C 16" (406.4) x 17" (431.8) x 23" (584.2) 1" (25.4) to 3" (76.2) 12" (304.8) 120 (55)
HTF55342C 208/240V, 50/60 Hz 5440 CC58114C 16" (406.4) x 17" (431.8) x 35" (889) 1" (25.4) to 3" (76.2) 24" (609.6) 175 (80)
*Process Tubes These furnaces are designed for use with a variety of process tubes including alumina, mullite, quartz and metallic.
For information on process tubes contact your process tube supplier or call your Lindberg/Blue M sales representative.
Tube Adapters One set of (2) included with furnace: Model HTF55122A, (2) 1" dia. adapters; Models HTF55322A/C, (2) 2" dia.
adapters; Model HTF55342C, (2) 3" dia. adapters.
Note: Required power cord, hardwiring and interconnecting wiring are not included.
21
1200C Digital, Single Setpoint processor-based digital control, a solid-state chart. Protects furnace and load in the
Controller power module, on/off circuit breaker and event of primary control circuit failure.
Control console includes advanced micro- thermocouple input jack. Includes micro- Overrides main controller and shuts off
processor-based digital control, a solid-state processor-based PID control (proportional, power to furnace if high limit is reached.
power module, on/off circuit breaker and integral, derivative), single program with Manual re-set required for safety. Operates
thermocouple input jack. Includes micro- multiple segments for ramp (up and down) via magnetic contacts through signal from
processor-based PID control (proportional, and dwell (timed hold) temperature con- independent thermocouple.
integral, derivative), single segment, single trol. See page 35 for more information.
Built-in adjustable high limit overtempera-
Optional RS485 Digital
setpoint, 1 ramp to setpoint. Built-in Communications Port
adjustable high limit overtemperature pro- ture protection. Simultaneous LED display
tection. Simultaneous LED display of actual of actual temperature vs. setpoint. May be RS485 Digital communications port avail-
temperature vs. setpoint. May be config- configured to display temperature in either able as an option. Allows controller to be
ured to display temperature in either C C or F. connected to a PC for remote monitoring
or F. and control of the furnace. Up to 30 units
Option B Overtemperature can be connected to one PC. Please see
1200C Digital Single Program, Control (OTC) page 35 for ordering information and addi-
Multiple Segment Programmable Adjustable digital overtemperature control, tional options.
Controller factory installed on selected control
Control console includes advanced micro- consoles with B suffix designation; see

Controller Digital With With Electrical Maximum Exterior Dimensions Ship Weight
Model No. Programmer Overtemp Volts, Hz Amps H x F-B x W in" (mm) lbs (kg)
Control
CC58114A 120V, 50/60Hz 30 10" (254) x 19" (482.6) x 14" (355.6) 40 (19)
CC58114C 208/240V, 50/60Hz 30 10" (254) x 19" (482.6) x 14" (355.6) 40 (19)
CC58114BA 120V, 50/60Hz 30 10" (254) x 19" (482.6) x 14" (355.6) 45 (21)
CC58114BC 208/240V, 50/60Hz 30 10" (254) x 19" (482.6) x 14" (355.6) 45 (21)
CC58114PA 120V, 50/60Hz 30 10" (254) x 19" (482.6) x 14" (355.6) 40 (19)
CC58114PC 208/240V, 50/60Hz 30 10" (254) x 19" (482.6) x 14" (355.6) 40 (19)
CC58114PBA 120V, 50/60Hz 30 10" (254) x 19" (482.6) x 14" (355.6) 45 (21)
CC58114PBC 208/240V, 50/60Hz 30 10" (254) x 19" (482.6) x 14" (355.6) 45 (21)


800-252-7100 www.lindbergbluem.com

Tube Furnaces
Phone:886-2-2767-3510 Http://www.sjcom.com.tw

Three Zone
1200C Split-Hinge, Horizontal or Vertical Use, Temperature Range 100C to 1200C

Furnace Electrical Watts Independent Exterior Dimensions *Process Tube Heated Length Heated Zone Ship Weight
Model No. Volts, Hz, 1 Controller H x F-B x W in" (mm) Diameter, in" (mm) in" (mm) in" (mm) lbs (kg)
HTF55347C 208/240V, 50/60 Hz 5355 CC58434C 16" (406.4) x 17" (431.8) x 35" (889) 1" (25.4) to 3" (76.2) 24" (609.6) 8/8/8" (203.2/203.2/203.2) 195 (89)
HTF55667C 208/240V, 50/60 Hz 11760 CC58434C 20" (508) x 21" (533.4) x 49" (1244.6) 3" (76.2) to 6" (152.4) 36" (914.4) 12/12/12" (304.8/304.8/304.8) 310 (141)
*Process Tubes These furnaces are designed for use with a variety of process tubes including alumina, mullite, quartz and metallic. For information on
process tubes contact your process tube supplier or call your Lindberg/Blue M sales representative.
Tube Adapters One set of (2) included with furnace: Model HTF55347C, (2) 3" dia. adapters; Models HTF55667C, (2) 3" dia. adapters.
Note: Required power cord, hardwiring and interconnecting wiring are not included.

1200C Three Zone Controller Option B Overtemperature Optional RS485 Digital


Control console includes advanced micro- Control (OTC) Communications Port
processor-based digital control, a solid- Adjustable digital overtemperature control, RS485 Digital communications port avail-
state power module, on/off circuit break- factory installed on selected control able as an option. Allows controller to be
er and thermocouple input jacks for each consoles with B suffix designation; see connected to a PC for remote monitoring
zone. Includes three microprocessor- chart. Protects furnace and load in the and control of the furnace. Up to 30 units
based PID controls (proportional, inte- event of primary control circuit failure. can be connected to one PC. Please see
gral, derivative), single segment, single set- Overrides main controller and shuts off page 35 for ordering information and addi-
point, 1 ramp to setpoint. Built-in power to furnace if high limit is reached. tional options.
adjustable high limit overtemperature Manual re-set required for safety. Operates
protection. Simultaneous LED display of via magnetic contacts through signal from
actual temperature vs. setpoint. May be independent thermocouple. Available sys-
configured to display temperature in tem on all three zone controller varieties.
either C or F.

Controller Digital With With Electrical Maximum Exterior Dimensions Ship Weight
Model No. Programmer Overtemp Volts, Hz, 1 Amps H x F-B x W in" (mm) lbs (kg)
Control
CC58434C 208/240V, 50/60Hz 20/30/20 17" (431.8) x 19" (482.6) x 14" (355.6) 60 (28)
CC58434BC 208/240V, 50/60Hz 20/30/20 17" (431.8) x 19" (482.6) x 14" (355.6) 60 (28)
22
1200C Three Zone Single Program, Center Zone Simultaneous LED display of actual temper-
Multiple Segment Programmable One microprocessor-based PID program- ature vs. setpoint.
Controller for Center Zone mable control (proportional, integral, deriv- End Zones
Control console includes advanced micro- ative), single program with multiple seg- Two microprocessor-based PID control
processor-based digital control, a solid-state ments for ramp (up and down) and dwell (proportional, integral, derivative), single
power module, on/off circuit breaker and (timed hold) temperature control. See page segment, single setpoint which mimic the
thermocouple input jacks for each zone. 35 for more information. Built-in adjustable programmed profile of the center zone
high limit overtemperature protection. controller, but allow an offset up to 100C
(+/- 50C). Offset is digitally displayed.
Controller Digital With With Electrical Maximum Exterior Dimensions Ship Weight
Model No. Programmer Overtemp Volts, Hz, 1 Amps H x F-B x W in" (mm) lbs (kg)
Control
CC58434PC 208/240V, 50/60Hz 20/30/20 17" (431.8) x 19" (482.6) x 14" (355.6) 60 (28)
CC58434PBC 208/240V, 50/60Hz 20/30/20 17" (431.8) x 19" (482.6) x 14" (355.6) 65 (30)

1200C Three Zone Single Program, thermocouple input jacks for each zone. trol. See page 35 for more information.
Multiple Segment Programmable Includes three microprocessor-based PID Built-in adjustable high limit overtempera-
Controllers programmable controllers (proportional, ture protection. Simultaneous LED display
Control console includes advanced micro- integral, derivative), single program with of actual temperature vs. setpoint. May be
processor-based digital control, a solid-state multiple segments for ramp (up and down) configured to display temperature in either
power module, on/off circuit breaker and and dwell (timed hold) temperature con- C or F.

Controller Digital With With Electrical Maximum Exterior Dimensions Ship Weight
Model No. Programmer Overtemp Volts, Hz, 1 Amps H x F-B x W in" (mm) lbs (kg)
Control
CC584343PC 208/240V, 50/60Hz 20/30/20 17" (431.8) x 19" (482.6) x 14" (355.6) 60 (28)
CC584343PBC 208/240V, 50/60Hz 20/30/20 17" (431.8) x 19" (482.6) x 14" (355.6) 65 (30)



800-252-7100 www.lindbergbluem.com
Phone:886-2-2767-3510 Http://www.sjcom.com.tw

Moldatherm Tube Adapters (each sold separately)


HEAT-UP One set (2) of tube adapters provided with each Lindberg/Blue M
Model HTF 55000 SeriesNo load
furnace. See below * for standard tube adapter supplied with each
1200
furnace. Interchangeable individual tube adapters which allow alter-
1100
native size process tubes are available; see chart.
1000
900
Model Model Model Model
Degrees Centigrade

800
700
Single Zone HTF55122 HTF55322 HTF55342
600
Adapter Size Three Zone HTF55347 HTF55667
500 0.75" 59510
400 1" 59511* 59521 59521
300
200
1.5" 59522 59522
100 2" 59523* 59523
0 2.5" 59524 59524
0 4 8 16 12
20 24 28 32
Minutes 3: 59525 59525* 59535*
Models 55122 & 55322 Models 55342 & 55347 4" 59536
5" 59537
Heat-Up, Model HTF55000 Series, No Load 6" 59538
Blank (Solid) 59519 59529 59529 59539
* One set of (2) included with furnace

COOL-DOWN Tube adapters prevent


Model HTF 55000 SeriesNo load
heat loss and improve
1200
temperature uniformity
1100
1000
within the furnace
900
chamber by insulating the
end vestibules.
Degrees Centigrade

800
700
600
500
400
300 23
200 Floor Stand, For Vertical
100 Installation
0
The optional Floor Stand is
0 1 2 3 5 46 7 8 9
Hours required to support HTF
Models 55342 & 55347 Model 55322 Series Tube Furnaces in a
vertical configuration. Floor
stands include all mounting
Cool-Down, Model HTF55000 Series, No Load hardware.

1200C LGO
Split-Hinge
UNIFORMITY PROFILES Tube Furnaces
Model HTF 55000 Series can be used in
1200
a horizontal or
1190 1200
Degrees Centigrade

Set-point
Temperature
vertical
1180
configuration.
1170
1160 Single Three
Zone Zone
1150 Models Model
55122 55347
1140 55322 (zoned
55342 8-8-8)
1130
Furnace Furnace Furnace Furnace
12 10 8 60 2 4 4 6 28 10 12 Model Model Model Model
Inches
Model 55122 1C over 2 1/8" Process Tube: 7/8" OD, 5/8" ID Single Zone HTF55122A HTF55322A HTF55342C
Model 55322 1C over 2 3/4" Process Tube: 2 3/8" OD, 2 1/8" ID HTF55322C
Model 55342 1C over 7" Process Tube: 3" OD, 2 3/4" ID
Three Zone HTF55347C HTF55667C
Model 55347 1C over 1/4" Process Tube: 3" OD, 2 3/4" ID
Tests performed with tube adapters and ends of process tube Floor Stand Model VFS551 VFS553
plugged with ceramic fiber.
Floor Stand Model VFS553 VFS553
Floor Stand Model VFS556

Uniformity Profiles, Model HTF55000 Series

Actual performance may vary depending on load, chamber size, sample placement, ambient temperature and environmental conditions.


800-252-7100 www.lindbergbluem.com

Tube Furnaces
Phone:886-2-2767-3510 Http://www.sjcom.com.tw

Applications
Annealing
Model STF54233, 1500C Solid Tube Crystal Growing
Furnace requires the Model CC58125C, Calibration
1500C Controller (left) ordered separately. Heat Treating

1500C Heavy Duty Tube Furnaces


(Independent Control)
Heavy duty 1500C tube furnaces are Removable side panels for easy Full adjustment of each zone over entire
24 available in single and three zone models, installation and electrical connection, operating range of 500C to 1500C
designed for high temperature metallurgi- simplified heating element replacement Center zone uniformity achieved and
cal, ceramic, chemical and electronic and adjustment operating length maximized through
research. High temperature insulation with adjustable profiling of end zones by
insulated end vestibules for better independent controller
Features uniformity and energy efficiency Controlled temperature uniformity
Double-end silicon carbide heating Long life, fast response type R thermo- achieved with independent setpoint of
elements mounted above and below the couples with 10' compensated lead end zones higher or lower than center
chamber wire and polarized plug zone
Heating elements with unique right
angle bend, sidewall mounting and com- Three Zone Models
pressed spacing at ends deliver fast heat- Three independent power circuits
up and recovery and offset heat loss (zones) with independent thermocou-
from end of process tube ples for control references

HEAT-UP/COOL-DOWN
Model STF54233C No load
1600

1400

1200
Degrees Centigrade

1000

800

600

400

200

0
Cool-down (Hrs) 0 1 2 3 4 5 6 7

Heat-up (min) 0 :15 :30 :45 1:00 1:15 1:30 1:45


Heat-up time Cool-down time
Holding Power 35%
Tests peformed with 2" diameter process tube.

Model STF54233C Heat-Up/Cool-Down, No load.


Actual performance may vary depending on load, chamber size, sample placement, ambient temperature and environmental conditions.


800-252-7100 www.lindbergbluem.com
Phone:886-2-2767-3510 Http://www.sjcom.com.tw

Single Zone
1500C Heavy-Duty Solid Tube Furnace, Temperature Range 500C to 1500C

Furnace Electrical Watts Independent Exterior Dimensions *Process Tube Heated Length Ship Weight
Model No. Volts, Hz, 1 Controller H x F-B x W in" (mm) Diameter, in" (mm) in" (mm) lbs (kg)
STF54233C 208/240V, 50/60 Hz 7200 CC58125C 19" (482.6) x 20" (508) x 25" (635) 2" (50.8) 12" (304.8) 250 (114)
STF54453C 208/240V, 50/60 Hz 6857 CC58125C 19" (482.6) x 30" (762) x 37" (939.8) 3" (76.2) 24" (609.6) 390 (177)

*Process Tubes These furnaces are designed for use with a variety of process tubes including alumina, mullite, quartz and metallic.
For information on process tubes contact your process tube supplier or call your Lindberg/Blue M sales representative.
Note: Required power cord, hardwiring and interconnecting wiring are not included.

1500C Digital, Single Setpoint processor-based digital control, a solid-state Protects furnace and load in the event of
Controller power module, on/off circuit breaker and primary control circuit failure. Overrides
Control console includes advanced micro- thermocouple input jack. Includes micro- main controller and shuts off power to fur-
processor-based digital control, a solid-state processor-based PID control (proportional, nace if high limit is reached. Manual re-set
power module, on/off circuit breaker and integral, derivative), single program with required for safety. Operates via magnetic
thermocouple input jack. Includes micro- multiple segments for ramp (up and down) contacts through signal from independent
processor-based PID control (proportional, and dwell (timed hold) temperature con- thermocouple.
integral, derivative), single segment, single trol. See page 35 for more information.
Built-in adjustable high limit overtempera-
Optional RS485 Digital
setpoint, 1 ramp to setpoint. Built-in Communications Port
adjustable high limit overtemperature pro- ture protection. Simultaneous LED display
of actual temperature vs. setpoint. May be RS485 Digital communications port avail-
tection. Simultaneous LED display of actual able as an option. Allows controller to be
temperature vs. setpoint. May be config- configured to display temperature in either
C or F. connected to a PC for remote monitoring
ured to display temperature in either and control of the furnace. Up to 30 units
C or F. Option B Overtemperature can be connected to one PC. Please see
1500C Digital Single Program, Control (OTC) page 35 for ordering information and addi-
Multiple Segment Programmable Adjustable digital overtemperature control, tional options.
Controller factory installed on selected control con- 25
Control console includes advanced micro- soles with B suffix designation; see chart.

Controller Digital With With Electrical Maximum Exterior Dimensions Ship Weight
Model No. Programmer Overtemp Volts, Hz, 1 Amps H x F-B x W in" (mm) lbs (kg)
Control
CC58125C 208/240V, 50/60Hz 60 10" (254) x 19" (482.6) x 14" (355.6) 40 (19)
CC58125BC 208/240V, 50/60Hz 60 10" (254) x 19" (482.6) x 14" (355.6) 40 (19)
CC58125PC 208/240V, 50/60Hz 60 10" (254) x 19" (482.6) x 14" (355.6) 40 (19)
CC58125PBC 208/240V, 50/60Hz 60 10" (254) x 19" (482.6) x 14" (355.6) 45 (21)

Three Zone
1500C Heavy-Duty Solid Tube Furnace, Temperature Range 500C to 1500C

Furnace Electrical Watts Independent Exterior Dimensions Process Tube Heated Length Heated Zone Ship Weight
Model No. Volts, Hz, 1 Controller H x F-B x W in" (mm) Diameter, in" (mm) in" (mm) in" (nominal mm) lbs (kg)
STF54459C 208/240V, 50/60 Hz 12600 CC58475C 20" (508) x 22.5" (571.5) x 37" (939.8) 3" (76.2) 24" (609.6) 6/12/6" (152.4/304.8/152.4) 390 (177)
STF54759C 208/240V, 50/60 Hz 20000 CC58485C 31" (787.4) x 33.5" (850.9) x 37" (939.8) 6" (152.4) 24" (609.6) 6/12/6" (152.4/304.8/152.4) 720 (327)
STF54779C 208/240V, 50/60 Hz 25000 CC58485C 31" (787.4) x 33.5" (850.9) x 49" (1244.6) 6" (152.4) 36" (914.4) 6/24/6 (152.4/609.6/152.4) 1000 (453)

Process Tubes These furnaces are designed for use with a variety of process tubes including alumina, mullite, quartz and metallic. For
information on process tubes contact your process tube supplier or call your Lindberg/Blue M sales representative.
Note: Required power cord, hardwiring and interconnecting wiring are not included. See page 26 for controller specifications.



800-252-7100 www.lindbergbluem.com

Tube Furnaces
Phone:886-2-2767-3510 Http://www.sjcom.com.tw

1200C Three Zone Controller 1 ramp to setpoint. Built-in adjustable


Control console is fully wired and high limit overtemperature protection.
includes advanced microprocessor-based Simultaneous LED display of actual
digital control, a solid-state power temperature vs. setpoint. May be
module, on/off circuit breaker and configured to display temperature in
thermocouple input jacks for each zone. either C or F
Includes three microprocessor-based PID
controls (proportional, integral, deriva- Three Zone 1500C Controller
tive), single segment, single setpoint, Model CC58475C

Controller Digital With With Electrical Maximum Exterior Dimensions Ship Weight
Model No. Programmer Overtemp Volts, Hz, 1 Amps H x F-B x W in" (mm) lbs (kg)
Control
CC58475C 208/240V, 50/60Hz 30/60/30 17" (431.8) x 21" (533.4) x 17" (431.8) 70 (32)
CC58485C 208/240V, 50/60Hz 60/120/60 17" (431.8) x 21" (533.4) x 24" (609.6) 80 (37)
Note: Required power cord, hardwiring and interconnecting wiring are not included.

1500C Three Zone Single Program, Simultaneous LED display of actual temper- primary control circuit failure. Overrides
Multiple Segment Programmable ature vs. setpoint. main controller, and shuts off power to fur-
Controller for Center Zone nace if high limit is reached. Manual re-set
End Zones required for safety. Operates via magnetic
Control console includes advanced micro-
processor-based digital control, a solid-state Two microprocessor-based PID control contacts through signal from independent
power module, on/off circuit breaker and (proportional, integral, derivative), single thermocouple.
thermocouple input jacks for each zone. segment, single setpoint which mimic the Optional RS485 Digital
programmed profile of the center zone Communications Port
Center Zone controller, but allow an offset up to 100C
(+/- 50C). Offset is LED displayed. RS485 Digital communications port avail-
One microprocessor-based PID program- able as an option. Allows controller to be
mable control (proportional, integral, deriv- Option B Overtemperature connected to a PC for remote monitoring
ative), single program with multiple seg- Control (OTC) and control of the furnace. Up to 30 units
ments for ramp (up and down) and dwell Adjustable digital overtemperature control, can be connected to one PC. Please see
(timed hold) temperature control. See page factory installed on selected control con- page 35 for ordering information and addi-
35 for more information. Built-in adjustable soles with B suffix designation; see chart. tional options.
26 high limit overtemperature protection. Protects furnace and load in the event of

Controller Digital With With Electrical Maximum Exterior Dimensions Ship Weight
Model No. Programmer Overtemp Volts, Hz, 1 Amps H x F-B x W in" (mm) lbs (kg)
Control
CC58475PC 208/240V, 50/60Hz 30/60/30 17" (431.8) x 21" (533.4) x 17" (431.8) 70 (32)
CC58485PC 208/240V, 50/60Hz 60/120/60 17" (431.8) x 21" (533.4) x 24" (609.6) 80 (37)

With Overtemp Control


CC58475PBC 208/240V, 50/60Hz 30/60/30 17" (431.8) x 21" (533.4) x 17" (431.8) 80 (37)
CC58485PBC 208/240V, 50/60Hz 60/120/60 17" (431.8) x 21" (533.4) x 24" (609.6) 90 (41)

1500C Three Zone Single Program, and dwell (timed hold) temperature con- factory installed on selected control
Multiple Segment Programmable trol. See page 35 for more information. consoles with B suffix designation; see
Controllers Built-in adjustable high limit overtempera- chart. Protects furnace and load in the
Control console includes advanced micro- ture protection. Simultaneous LED display event of primary control circuit failure.
processor-based digital control, a solid-state of actual temperature vs. setpoint. May be Overrides main controller and shuts off
power module, on/off circuit breaker and configured to display temperature in either power to furnace if high limit is reached.
thermocouple input jacks for each zone. C or F. Manual re-set required for safety. Operates
Includes three microprocessor-based PID via magnetic contacts through signal from
programmable controllers (proportional, Option B Overtemperature independent thermocouple.
integral, derivative), single program with Control (OTC)
multiple segments for ramp (up and down) Adjustable digital overtemperature control,

Controller Digital With With Electrical Maximum Exterior Dimensions Ship Weight
Model No. Programmer Overtemp Volts, Hz, 1 Amps H x F-B x W in" (mm) lbs (kg)
Control
CC584753PBC 208/240V, 50/60Hz 30/60/30 17" (431.8) x 21" (533.4) x 17" (431.8) 80 (37)
CC584853PBC 208/240V, 50/60Hz 60/120/60 17" (431.8) x 21" (533.4) x 24" (609.6) 90 (41)



800-252-7100 www.lindbergbluem.com

Tube Furnaces
Phone:886-2-2767-3510 Http://www.sjcom.com.tw

Tube adapters
prevent heat loss and
improve temperature
uniformity within
the furnace chamber
by insulating the end
vestibules. One set
(2) of 2" tube
adapters provided Applications
with each model.
Heat Treating
Sintering
Annealing
Atmosphere
Model STF55433C, 1500C Solid Tube Processing
Furnace with integrated multiple segment Melting
controller; for multiple segment program- Fusing
mable control order Model STF55433PC.
(Process tube shown not included).

1500C General Purpose Tube Furnaces


(Integral Control)
1500C General Purpose Tube Furnaces hold) temperature control. See page 35 Option B Overtemperature
with integral control are designed for a for more information Control (OTC)
range of applications which require process- Adjustable high limit overtemperature Adjustable digital overtemperature
ing flexibility with fast heat-up and recovery. protection control, protects furnace and load in the
Energy efficient Moldatherm insulation event of primary control circuit failure.
increases temperature uniformity, improves Simultaneous LED display of actual 27
temperature vs. setpoint Available on selected models with B
energy efficiency and helps to maintain low suffix designation; see chart
exterior cabinet temperatures May be configured to display
during operation. temperature in either C or F Optional RS485 Digital
Digital Multiple Program, Multiple Communications Port
Features
Segment Programmable Controller RS485 Digital communications port
Accommodates 1", 2" and 3" O.D. available as an option. Allows controller
process tubes (customer supplied) Multiple programs and segments for ramp
to be connected to a PC for remote moni-
Silicon carbide heating elements (up and down) and dwell (timed hold)
toring and control of the furnace. Up to
positioned above and below tube and temperature control. See page 35 for
30 units can be connected to one PC.
Type R thermocouple combine to more information
Please see page 35 for ordering informa-
maintain temperature stability at 1500C Adjustable high limit overtemperature tion and additional options
Microprocessor-based PID programma- protection
Ordering Information,
ble control (proportional, integral, LED display of actual temperature Moldatherm Tube Adapters
derivative) prevents overshoot May be configured to display
Furnace Model Furnace Model Furnace Model
Digital Single Program, Multiple temperature in either C or F Size STF55433C STF55433PC STF55433PBC
Segment Programmable Controller Catalog No. Catalog No. Catalog No.
Single program with multiple segments 1" 7100-2444-070 7100-2444-070 7100-2444-070
for ramp (up and down) and dwell (timed 2"* 7100-2444-068 7100-2444-068 7100-2444-068
3" 7100-2444-069 7100-2444-069 7100-2444-069
* One set of (2) included with furnace
1500C Solid, Integral Controller, Temperature Range 500C to 1500C Each sold separately

Furnace Electrical Watts Integral Exterior Dimensions Process Tube Heated Length Ship Weight
Model No. Volts, Hz, 1 Controller H x F-B x W in" (mm) Diameter, in" (mm) in" (mm) lbs (kg)
STF55433C 208/240V, 50/60 Hz 6000 Multi Seg/1 Prog 17" (431.8) x 19" (482.6) x 23" (584.2) 1", 2", 3" (25.4 - 76.2) 12" (304.8) 270 (123)
STF55433PC 208/240V, 50/60 Hz 6000 Multi Seg/Multi Prog 17" (431.8) x 19" (482.6) x 23" (584.2) 1", 2", 3" (25.4 - 76.2) 12" (304.8) 270 (123)
STF55433PBC 208/240V, 50/60 Hz 6000 Multi Seg/Multi Prog/OTC 17" (431.8) x 19" (482.6) x 23" (584.2) 1", 2", 3" (25.4 - 76.2) 12" (304.8) 270 (123)

Process Tubes These furnaces are designed for use with a variety of process tubes including alumina, mullite, quartz and metallic. For
information on process tubes contact your process tube supplier or call your Lindberg/Blue M sales representative.
Tube Adapters One set of (2) 2" dia. adapters included with furnace. Note: Required power cord and hardwiring are not included.



800-252-7100 www.lindbergbluem.com

Tube Furnaces
Phone:886-2-2767-3510 Http://www.sjcom.com.tw

Applications
Atmosphere
Processing
Sintering
Annealing
(Top) Model STF54434C 1700C Tube Furnace Crystal Growing
shown with controller CC59256PCOMC. Heat Treating
(Process tube shown, not included).

1700C High Temperature Tube Furnaces


(Independent Control)
High temperature tube furnaces achieve heat-up and recovery, reduced thermal Double shell construction and
28 excellent temperature uniformity at 1700C process cycle time, and cost savings convection cooling design reduces
with rapid heat-up, recovery and cool-down. through quicker throughput and energy exterior surface temperature
Moldatherm graduated density insulation efficiency Removable louvered panels provide
adds to safety and performance by forming Heating elements tolerate rapid cycling easier access to heating elements and
enhanced insulation protection between over extended periods; elements are thermocouple
the high temperature chamber and exterior easily replaceable without the need to
cabinet surface. Moldatherm graduated den- match resistance values
sity insulation, combined with molyb-
Heating elements are sidewall mounted
denum disilicide heating elements, provide
superior radial and linear temperature to protect integrity of chamber roof;
uniformity with resistance to thermal shock. roof penetrations are avoided
The independent digital temperature Type B thermocouples assure accurate
control (ordered separately) has multiple temperature measurement and long
programmable segments useful for a wide thermocouple life; 10' compensated lead Moldatherm Graduated
range of applications. wire with polarized plug included Density Insulation

Moldatherm end vestibules accept 3" Moldatherm graduated density


Features O.D. process tube (customer supplied) insulation adds to safety and perfor-
Heating elements with unique right Optional Moldatherm vestibules per- mance by forming enhanced insulation
angle bend and sidewall mounting mit operation with 1", 2" and 3" O.D. protection between the high temperature
deliver exceptional energy release, fast process tubes for increased versatility chamber and exterior cabinet surface.

1700C High Temperature Tube Furnace, Temperature Range 500C to 1700C

Furnace Electrical Watts Independent Exterior Dimensions Process Tube Heated Length Ship Weight
Model No. Volts, Hz, 1 Controller H x F-B x W in" (mm) Diameter, in" (mm) in" (mm) lbs (kg)
STF54434C 208/240V, 50/60 Hz 5000 CC59256PCOMC 19" (482.6) x 16" (406.4) x 22" (558.8) 3" (76.2) 12" (304.8) 95 (43)
STF54454C 208/240V, 50/60 Hz 10000 CC59256PCOM2CKT 19" (482.6) x 16" (406.4) x 34" (863.6) 3" (76.2) 24" (609.6) 165 (75)

Process Tubes These furnaces are designed for use with a variety of process tubes including alumina, mullite, quartz and metallic. For information
on process tubes contact your process tube supplier or call your Lindberg/Blue M sales representative.
Vestibule Set One 3" vestibule set and sleeves included; other size vestibule sets and sleeves may be ordered separately.



800-252-7100 www.lindbergbluem.com
Phone:886-2-2767-3510 Http://www.sjcom.com.tw

1700C Controller, Programmable, displays simultaneously indicate actual tem- Option B Overtemperature
With Communications perature and setpoint temperature. High Control (OTC)
Lindberg/Blue M 1700C Programmable limit overtemperature protection is stan- Adjustable digital overtemperature
Controllers provide multiple programs and dard.The control console includes a circuit control, factory installed on selected
multiple segments for ramp (up and down) breaker, power module, transformer and control consoles with B suffix designa-
and dwell (timed hold) temperature con- cooling fans. tion; see chart. Protects furnace and load
trol.The controller visually displays ramp Controllers include RS485 data port (com- in the event of primary control circuit
rate, dwell time, program segment and per- munications card and port) for connection failure. Overrides main controller and
cent power output. A holdback feature to remote computer, allowing modification, shuts off power to furnace if high limit is
allows the operator to set a process vs set- interrogation and data transfer of all instru- reached. Manual re-set required for safety.
point temperature value which, when ment control and configuration parameter. Operates via magnetic contacts through
exceeded, holds the program to allow the Up to 30 units can be connected to one signal from independent thermocouple.
process to catch up. Please see page 35 for PC. Software is not included, but is avail-
additional information. able as an option. Please see page 35 for
The controller includes a selectable self- additional options and information.
tuning feature which sets the best PID set-
tings for the thermal process.Two digital

Temperature Profile
5 1/4"
1C

12" Chamber
Model STF 54434C
1700C Set-pointNo Load
3"x24" 998 Alumina process tube
Ends of tube packed with 3"4" of Bulk Ceramic fiber.

Uniformity Profile, Model STF54434C, Programmable Controller, 1700C


1700C, No Load. Model CC59256PCOMC.
29
1700 Controller, Programmable, with Communications

Controller Digital With With Electrical Exterior Dimensions Ship Weight


Model No. Programmer Overtemp Volts, Hz H x F-B x W in" (mm) lbs (kg)
Control
CC59256PCOMC 208/240V, 50/60Hz 10" (254) x 15" (381) x 21" (533.4) 130 (59)
CC59256PBCOMC 208/240V, 50/60Hz 10" (254) x 15" (381) x 21" (533.4) 130 (59)
CC59256PCOM2CKTC 208/240V, 50/60Hz 30" (762) x 15" (381) x 22" (558.8) 230 (105)
CC59256PBCOM2CKTC 208/240V, 50/60Hz 30" (762) x 15" (381) x 22" (558.8) 230 (105)
Note: Required power cord, hardwiring and interconnecting wiring are not included.

Vestibules
Furnace Vestibule Catalog No. (Ordered Separately)
Optional Moldatherm vestibules permit
operation with 1", 2" and 3" O.D. process Model Number 1" dia. 2" dia. 3" dia.
tubes for increased versatility.Two STF54434C 7219-2147-001 7219-2147-002 7219-2147-003*
vestibules are required for each furnace. STF54454C 7219-2147-013 7219-2147-012 7219-2147-011*
One 3" vestibule set is included and
installed with each furnace. * One set of (2) included with furnace

Moldatherm Sleeves Furnace Sleeve Catalog No. (Ordered Separately)


Tube sleeves may be placed over Model Number 1" dia. 2" dia. 3" dia.
customer supplied process tubes to STF54434C 7219-2134-001 7219-2134-002 7219-2134-003*
reduce thermal shock to the process tube.
Sleeves must be ordered separately. All STF54454C 7219-2134-013 7219-2134-012 7219-2134-011*
tube sleeves are 3" long. * One set of (2) included with furnace

Actual performance may vary depending on load, chamber size, sample placement, ambient temperature and environmental conditions.



800-252-7100 www.lindbergbluem.com

Crucible Furnaces
Phone:886-2-2767-3510 Http://www.sjcom.com.tw

Applications
Melting
Annealing
Heat
Model CF56622C Crucible Furnace. Treating

30 1200C Crucible Furnace,


Top Loading
1200C Crucible furnaces are ideal for use Features Moldatherm insulation protects
in ceramics, electronics, glass, metallurgy Requires independent controller vestibule, improves energy efficiency
and superconductor materials research. (ordered separately, see chart) PlatinelII thermocouple with 10'
These models require independent con- compensated lead wire and polarized
trollers (ordered separately). Unitized heating and insulation element
with helical wire coil embedded in plug for long life and accurate tempera-
Moldatherm insulation for maximum ture measurement
heat transfer to the work load Moldatherm ceramic fiber hearthplate
Cover plug with Moldatherm supports load and protects furnace
insulation and handle for safe removal from spillage

Model CC58114C Controller



800-252-7100 www.lindbergbluem.com
Phone:886-2-2767-3510 Http://www.sjcom.com.tw

HEAT-UP/COOL-DOWN
Model CF56622C No load
1600

1400

1200

Degrees Centigrade
1000

800

600

400

200

0
Heat-up (Min) 0 15 30 45 1.00 1.15 1.30 1.45

Cool-down (Hrs) 0 1 2 3 4 5 6 7

Heat-up (Set-point 1200C) Cool-Down


38% holding power @ 1200C
Chamber uniformity 5%C over bottom two-thirds of heated length.
Model CF56622C, Heat-Up/Cool-Down, No Load

Crucible Furnaces, 1200C, Independent Control, Temperature Range 100C to 1200C

Furnace Electrical Top Opening Chamber Depth Exterior Dimensions Ship Weight
Model No. Volts, Hz Watts Temp Controller ID inches (mm) inches (mm) H x F-B x W in" (mm) lbs (kg)
CF56622C 208/240V, 50/60 Hz 1700 1200C CC58114C 5" (127) 8" (203.2) 16" (406.4) x 15" (381) x 15" (381) 52 (24)
CF56822C 208/240V, 50/60 Hz 2600 1200C CC58114C 7.5" (190.5) 8" (203.2) 19" (482.6) x 20" (508) x 20" (508) 105(48)
Crucibles: These furnaces are designed for use with a variety of crucibles including alumina, mullite, quartz and metallic. For information on cru-
cibles contact your crucible supplier or call your Lindberg/Blue M sales representative.
Note: Required power cord, hardwiring and interconnecting wiring are not included.
1200C Digital, Single Setpoint advanced microprocessor-based digital tion; see chart. Protects furnace and load in
Controller control, a solid-state power module, on/off the event of primary control circuit failure. 31
circuit breaker and thermocouple input Overrides main controller and shuts off
Control console includes advanced micro- jack. Includes microprocessor-based PID power to furnace if high limit is reached.
processor-based digital control, a solid-state control (proportional, integral, derivative), Manual re-set required for safety. Operates
power module, on/off circuit breaker and single program with multiple segments for via magnetic contacts through signal from
thermocouple input jack. Includes micro- ramp (up and down) and dwell (timed independent thermocouple.
processor-based PID control (proportional, hold) temperature control. See page 35 for
integral, derivative), single segment, single more information. Built-in adjustable high Optional RS485 Digital
setpoint, 1 ramp to setpoint. Built-in limit overtemperature protection. Communications Port
adjustable high limit overtemperature pro- Simultaneous LED display of actual temper- RS485 Digital communications port avail-
tection. Simultaneous LED display of actual ature vs. setpoint. May be configured to dis- able as an option. Allows controller to be
temperature vs. setpoint. May be config- play temperature in either C or F. connected to a PC for remote monitoring
ured to display temperature in either and control of the furnace. Up to 30 units
C or F. Option B Overtemperature can be connected to one PC. Please see
Control (OTC) page 35 for ordering information and addi-
1200C Digital Single Program, tional options.
Multiple Segment Programmable Adjustable digital overtemperature
Controller control, factory installed on selected
Control console is fully wired and includes control consoles with B suffix designa-

Controller Digital With With Electrical Maximum Exterior Dimensions Ship Weight
Model No. Programmer Overtemp Volts, Hz Amps H x F-B x W in" (mm) lbs (kg)
Control
CC58114C 208/240V, 50/60Hz 30 10" (254) x 19" (482.6) x 14" (355.6) 35 (16)
With Programmer
CC58114PC 208/240V, 50/60Hz 30 10" (254) x 19" (482.6) x 14" (355.6) 35 (16)

With Overtemp Control


CC58114BC 208/240V, 50/60Hz 30 10" (254) x 19" (482.6) x 14" (355.6) 35 (16)
CC58114PBC 208/240V, 50/60Hz 30 10" (254) x 19" (482.6) x 14" (355.6) 40 (19)

Actual performance may vary depending on load, chamber size, sample placement, ambient temperature and environmental conditions.


800-252-7100 www.lindbergbluem.com

Crucible Furnaces
Phone:886-2-2767-3510 Http://www.sjcom.com.tw

Programmable
Controller,
1700C Model
CC59256PCOMC.

Applications
Sintering
Melting
Model CF56724C 1700C Crucible Annealing
Furnace is used with Controller Model Atmosphere
CC59256PCOMC (left), ordered Processing
separately.

32 1700C Crucible Furnace, Top or


Bottom Loading
Heat-Up/Cool-Down
1700C Features
CF56724C No load
Requires independent controller BOTTOM LOADING TOP LOADING
1700
1600 (ordered separately, see chart)
1400
Chamber is accessed by top or
Degrees Centigrade

1200
1000
bottom with manually operated lifting
HEATED
800 mechanism; work load may be raised CHAMBER
600 and lowered with convenience
400
200
and safety WORK LOAD
CRUCIBLE
0 Long-life molybdenum disilicide
0 5 10 15 20 25 30 35 40 45 50 55
Minutes heating elements resist thermal shock,
Heat-Up Atmosphere Cool-Down
Bottom or top loading furnace configuration
withstand rapid cycling over
extended periods
Heat-Up/Cool-Down, Model CF56724C Individual elements easily replaceable
without matching resistance values Dual access chamber permits top or
The Model CF56724C Crucible Furnace is bottom loading. Processing can be done in
used for high temperature research Elements mounted on four sides of
air or in a protective inert atmosphere
under three methods of processing: air, chamber for fast response and
when bottom loaded.
controlled atmosphere, or vertical tube recovery
orientation using an interchangeable Forced-air blowers circulate ambient
vestibule as an insulating sleeve (which air throughout the double-wall Note: This crucible furnace chamber is
requires a vertical tube adaptation kit). crucible cabinet to minimize exterior not atmosphere tight.
Graduated density Moldatherm insulation surface temperature
combined with a unique right-angle bend
Long-life Type B thermocouple for
heating element, sidewall mounted,
accurate high temperature measure-
delivers excellent chamber uniformity, fast
ment. Includes 10' compensated
heat-up and recovery, and energy
lead wire with polarized plug
conserving performance.

Actual performance may vary depending on load, chamber size, sample placement, ambient temperature and environmental conditions.


800-252-7100 www.lindbergbluem.com
Phone:886-2-2767-3510 Http://www.sjcom.com.tw

Crucible Furnaces, 1700C, Independent Control, Temperature Range 500C to 1700C, 5,000 Watts

Vestibule Vestibule Working Ship


Top Opening Bottom Opening Depth Exterior Dimensions Weight
Model No. Voltage, Hz Controller ID in" (mm) ID in" (mm) ID in" (mm) H x F-B x W in" (mm) lbs (kg)
CF56724C 208/240V, 50/60 Hz CC59256PCOMC 6.5" (165.1 mm)2 5" (127 mm) 6.5" (165.1 mm) 35.5" (901.7) x 20" (508) x 19.5" (495.3) 250 (114)
Note: Required power cord, hardwiring and interconnecting wiring are not included.

1700C Controller, Programmable, The controller includes a selectable self- Option B Overtemperature
With Communications tuning feature which sets the best PID set- Control (OTC)
Lindberg/Blue M 1700C Programmable tings for the thermal process.Two digital Adjustable digital overtemperature control,
Controllers provide multiple programs and displays simultaneously indicate actual tem- factory installed on selected control
multiple segments for ramp (up and down) perature and setpoint temperature. High consoles with B suffix designation; see
and dwell (timed hold) temperature con- limit overtemperature protection is stan- chart. Protects furnace and load in the
trol.The controller visually displays ramp dard.The control console includes a circuit event of primary control circuit failure.
rate, dwell time, program segment and per- breaker, power module, transformer and Overrides main controller, and shuts off
cent power output. A holdback feature cooling fans. power to furnace if high limit is reached.
allows the operator to set a process vs set- Controllers include RS485 data port (com- Manual re-set required for safety. Operates
point temperature value which, when munications card and port) for connection via signal from independent thermocouple.
exceeded, holds the program to allow the to remote computer, allowing modification,
process to catch up. Please see page 35 for interrogation and data transfer of all instru-
additional information. ment control and configuration parameter.
Up to 30 units can be connected to one
PC. Software is not included, but is avail-
able as an option. Please see page 35 for
additional options and information.

Controller Digital With With Electrical Exterior Dimensions Ship Weight


Model No. Programmer Overtemp Volts, Hz H x F-B x W in" (mm) lbs (kg)
Controller
CC59256PCOMC 208/240V, 50/60Hz 10" (254) x 15" (381) x 21" (533.4) 130 (59)
CC59256PBCOMC 208/240V, 50/60Hz 10" (254) x 15" (381) x 21" (533.4) 130 (59) 33
Chamber uniformity over center 5.5" heated chamber length is 1C at 1700C (no atmosphere).

Processing Options VERTICAL TUBE


ATMOSPHERE PROCESSING
In addition to air processing, the 1700C AIR PROCESSING PROCESSING
OUT
crucible furnace can be used for A
CUSTOMER
atmosphere processing using an inverted SUPPLIED
ceramic crucible (included) over the load B
PROCESS TUBE

forming a muffle. Inert gas is supplied CERAMIC


MUFFLE C
through inlet and outlet tubes (customer D

supplied). Gas flow is controlled via an ATMOSPHERIC HEATED


adjustable N2 flowmeter, included. EMVIRONMENT CHAMBER
FLOW
METER
For use in a vertical tube configuration, D
either air or controlled atmosphere 1700 C MAX. TEMP. 1650 C MAX. TEMP.
B
processing, the furnace requires an
A
optional Adaptation Kit (see chart) ordered
to match the size of the desired process May be configured for air or atmosphere processing, 1600 C max. temp.
tube (customer supplied). vertical tube/atmosphere processing.

Vertical Tube Adaption Kit vestibules (D), two tube insulating sleeves
Adaption Kit Diameter (B) with cover plate (C) and outlet plugs
Model No. inches (mm) The Vertical Tube Adaption Kit creates a
1700C tube furnace with air or inert (A). Process tube and atmosphere piping
atmosphere control using the Model are not included. Contact your
VTINS156724 1" (25.4)
CF56724C crucible furnace as the heating Lindberg/Blue M sales representative for
VTINS256724 2" (50.8) source. Each field installed kit (see ordering more information.

VTINS356724 3" (76.2) chart) is selected based on intended


process tube size, and includes two tube



800-252-7100 www.lindbergbluem.com

Hot Plates
Phone:886-2-2767-3510 Http://www.sjcom.com.tw

Applications
Heating
Boiling
Drying
Evaporating
Model HP53014C Hot Plate
Digesting

Model HP53025C Hot Plate

Hot Plates, Heavy Duty


Solid-State Control Models Independent On/Off switch Unique placement of heating elements
34 Solid-state electronic controls deliver Adjustable temperature control dial provides uniform temperatures over top
rapid heat-up, precise control and with red power ON and amber power plate surface at each of three settings
exceptional reliability APPLIED indicator lights Low thermal conductivity insulation
Moldatherm insulation/heating Heavy-gauge top plate is mounted optimizes energy use, accelerates
element modules with extremely low securely to a reinforced steel base; a heat-up and cool-down
thermal mass optimizes energy use, high temperature painted finish Moldatherm insulation holds coiled
reduces maintenance and accelerates resists wear heating elements in place; elements
heat-up and cool-down 10' power cord included provide direct radiant heat to top plate
Unique helically coiled heating Heat-resistant alloy top plate is attached
element and heat-resistant top plate On/Off Control Models, to reinforced steel base; a high
configuration combine to create HP53025 Series temperature painted finish resists wear
uniform top plate temperature
Three On/Off toggle switches mounted
on the main control panel control each
of three independent heating elements
Hot Plates, 400C, Solid-State Control

Hot Plate Top Plate Electrical Plate Working Surface Overall Height Ship Weight
Model No. Aluminum Steel Volts, Hz, 1 Watts Temp F-B x W, inches (mm) inches (mm) lbs (kg)
HP53013A 1/4" N/A 120V, 50/60 Hz 1800 to 400C 10" (254) x 12" (304.8) 8.5" (215.9) 20 (9)
HP53014C N/A 5/16" 208/240, 50/60 Hz 2400 to 400C 12" (304.8) x 20" (508) 8.5" (215.9) 46 (21)
HP53015C N/A 1/4" 208/240, 50/60 Hz 3600 to 400C 12" (304.8) x 30" (762) 8.5" (215.9) 74 (34)
HP53016A 1/4" N/A 120V, 50/60 Hz 1800 to 400C 5" (127) x 22" (558.8) 8.5" (215.9) 23 (11)

Hot Plate, 400C, 3-Switch On/Off Control

Hot Plate Top Plate Electrical Low Medium High Plate Working Surface Overall Height Ship Weight
Model No. Aluminum Steel Volts, Hz, 1 Temp/Watts Temp/Watts Temp/Watts F-B x W, inches (mm) inches (mm) lbs (kg)
HP53025A* N/A 3/8" 120V, 50/60 Hz 204C/1200 316C/2400 400C/3600 18" (457.2) x 24" (609.6) 5.75" (146.05) 110 (50)
HP53025C N/A 3/8" 208/240V, 50/60 Hz 204C/1200 316C/2400 400C/3600 18" (457.2) x 24" (609.6) 5.75" (146.05) 110 (50)

*Required power cord and hardwiring are not included.




800-252-7100 www.lindbergbluem.com
Controllers & Accessories
Phone:886-2-2767-3510 Http://www.sjcom.com.tw

Personal
Computer

Furnace Furnace

Furnace

Digital Single Program, Multiple Digital Multiple Program, Multiple RS485 Digital Communications Port
Segment Programmable Controller Segment Programmable Controller Digital Communications Features
Single program with 16 segments 30 programs and 300 segments for Provides two-way communications
for ramp (up and down) and dwell ramp (up and down) and dwell (timed between furnace and remote computer
(timed hold) temperature control hold) temperature control (maximum of (accessory #7043 required). Computer
PID based control 99 segments per program) not included.
Simultaneous LED display of actual Program patterns can be based on Allows remote monitoring and control
temperature vs. setpoint either time or rate of furnace equipment
Super Control (Fuzzy Logic) suppresses PID based control Ability to connect up to 30 furnaces to
overshooting of temperature Large 5-digit LED display of actual one personal computer
Customer initiated Auto-Tune function temperature 9-pin connection ports
will adjust and update the PID LCD display provides trend recording Compatible with SPECVIEW PLUSTM
parameters to the optimum settings for function, graphic prompts, configurable and most communications software
new temperature setpoints display data and custom messages (set packages
1/16 DIN controller by customer) 35
SPECVIEW PLUSTM Software Features
Accuracy of controller: +/-0.3% Eight PID settings per segment
Automatic Configuration
RS485 digital communications port 1/4 DIN controller
Data logging of any variable with
available as an option Accuracy of controller: +/-0.1% historic screen display
RS485 digital communications port Trend Charts
available as an option
Parameter Access so setpoints and high
limits can be changed from PC
Monitors and controls up to 30 furnaces
with one software package

RS-485 Ordering Information


To add RS-485 Digital Communications Port to Furnace or Control Twenty-five foot cable and RS-232 converter for connection of fur-
Console model, add COM to model number before last letter in nace/control console RS-485 port to personal computer serial port.
model number (see examples below). Please contact your Required for first unit connection.
Lindberg/Blue M sales representative for pricing and lead times. Accessory No. 7043

Old Part# New Part# Cable to connect multiple (2+) furnaces, ovens or other equipment
BF51842C BF51842COMC with Yokogawa communications capabilities to first furnace wih
Yokogawa RS-485 communications port.
BF51433PBC BF51433PBCOMC Accessory No. 7044
CC58114C CC58114COMC
CC58125BC CC58125BCOMC SPECVIEW PLUS software package includes disc and instructional
book.
Accessory No. 7046



800-252-7100 www.lindbergbluem.com
Phone:886-2-2767-3510 Http://www.sjcom.com.tw

Box Furnaces
Tube Furnaces
Crucible Furnaces
Furnace Controllers
Hot Plates
Gravity Convection Ovens
Mechanical Convection Ovens
Vacuum Ovens

Kendro Laboratory Products


manufacturer of laboratory
ovens, furnaces, water baths
and allied equipment. Factory
Ovens
installed options and product
modifications are available
and must be specified
when ordering. Contact
your Lindberg/Blue M
Sales Representative for
Furnaces more information on these
and other high perfor-
mance laboratory products.

Baths
All published dimensions performance data are nominal.
Specifications are subject to change without notice.

For Ordering or Technical Information


USA Kendro Laboratory Products Asheville, NC USA Tel. +1 (800) 252-7100 Fax. +1 (828) 645-3368 info@kendro.com
Canada Kendro Laboratory Products Asheville, NC USA Tel. +1 (800) 447-3826 Fax. +1 (828) 645-3368 info@kendro.com
Outside North America
Kendro Laboratory Products, International Sales Asheville, NC USA Tel. +1 (828) 658-2711 Fax. +1 (828) 645-9466 info@kendro.com
Internet www.kendro.com

Quality Products Lifetime Care

Registered to ISO 9001. Kendro Laboratory Products meet or exceed stringent quality and product safety standards: CE for the European Union,
and UL, cUL or
CSA standards for North America. 2002 Kendro Laboratory Products. All Rights Reserved

Printed in USA
(06/02) LB104