T3S/ T3H/ T4M/ T4L

Digital switch setting type

Features
Various size by DIN specification
(W48H48, W48H96, W72H72, W96H96mm)
Accuracy: F.S. 0.5%(Except T3S)
Free power: T3S Series

Ordering information
T 3 S B 4 R P 4 C

Unit C
F

0 -99 to 199, -99.9 to 199.9


1 0 to 99.9
2 0 to 199
Temperature range
4 0 to 399
8 0 to 799
A 0 to 999
C 0 to 1200
F 600 to 1600

P DPt100
Sensor input type J J(IC)
K K(CA)
R R(PR)

R Relay output
Control output
S SSR drive voltage output
C Current outut(DC4-20mA)
Power supply 3 110/220VAC 50/60Hz
4 100-240VAC 50/60Hz
Control method
B ON/OFF, P control

S DIN W48H48mm
Size H DIN W48H96mm
M DIN W72H72mm
L DIN W96H96mm
Digit 3 999(3digit)
4 9999(4digit)
Item
T Temperature Controller

Refer to the H-89 about sensor temperature range for selection.

H-88
Standard type

Temperature range for each sensor (A)


Photo
electric
sensor
Series T3S T3H T4M / T4L
(B)
Sensor Thermocouples RTD Thermocouples RTD Thermocouples RTD Fiber
optic
input typ J(IC) K(CA) DPt100 J(IC) K(CA) DPt100 J(IC) K(CA) R(PR) DPt100 sensor
1600
() 1600 1200 (C)
1200 Door/Area
Standard scale range

999 sensor
1000
799 799 799
800
600 (D)
399 399 399 399 800 399 399 399 399 600 399 Proximity
400 sensor
199 199 199 199.9
200
99.9 99.9
100 (E)
0 Pressure
sensor
-100
-99 -99.9

In case input sensor is R(PR) type, it is not available to perform correct control under 600. (F)
Rotary
encoder

Specifications (G)
Connector/
Socket
Series T3S T3H T4M T4L
Power supply 100-240VAC 50/60Hz 110/220VAC 50/60Hz (H)
Temp.
controller
Allowable voltage range 90 to 110% of power supply
Power consumption Max. 5VA Max. 3VA (I)
SSR/
Power
Display method 7 Segment(red) LED method controller

Character size(WH) 4.08.0mm 6.010.0mm 7.29.8mm 9.514.2mm


(J)
Counter
Display accuracy F.S. 1% rdg 1digit F.S. 0.5% rdg 1digit
Setting type Digital setting
(K)
Setting accuracy F.S. 1% F.S. 0.5% Timer

Thermocouples: K(CA), J(IC), R(PR) / RTD: DPt100


Sensor input There is no R(PR) in T3S, T3H Series. (L)
Panel
meter
Input line resistance Thermocouples: Max. 100 / RTD: Allowable line resistance max. 5 per a wire
(M)
ON/OFF control Hysteresis: F.S. 0.5% 0.2% fixed Hysteresis: F.S. 0.2 to 3% variable Tacho/
Control Speed/ Pulse
method Proportional band: F.S. 3% fixed meter
P control Proportional band: F.S. 1 to 10% variable, Period: 20sec. fixed
Period: 20sec. fixed
(N)
Display
RESET adjuster range F.S. 3% variable(revision of control deviation) unit

Relay output :
250VAC 2A 1c (O)
Relay output: 250VAC 3A 1c Sensor
SSR drive voltage output : controller
Control output SSR output: 24VDC 3V 20mA Max.
12VDC 3V 20mA Max.
Current output: DC4-20mA (load 600 Max.)
Current output : (P)
Switching
DC4-20mA (load 600 Max.) mode power
supply
Self-diagnosis Built-in burn out function (cut off output when sensor is disconnected)
(Q)
Stepper
Insulation resistance Min. 100M (at 500VDC megger) motor&
Driver&Controller
Dielectric strength 2,000VAC 50/60Hz for 1 min.
(R)
Noise resistance 1kV the square wave noise(pulse width: 1) by the noise simulator Graphic/
Logic
panel
Mechanical 0.75mm amplitude at frequency of 10 to 55Hz(for 1 min.) in each of X, Y, Z directions for 1 hour
Vibration (S)
Malfunction 0.5mm amplitude at frequency of 10 to 55Hz(for 1 min.) in each of X, Y, Z directions for 10 min. Field
network
Mechanical 300m/s(approx. 30G) in each of X, Y, Z directions for 3 times device
Shock
Malfunction 100m/s(approx. 10G) in each of X, Y, Z directions for 3 times (T)
Software
Relay Mechanical Min. 10,000,000 operations
life cycle Electrical Min. 100,000 operations(250VAC 3A at resistive load) (U)
Other
Environ- Ambient temperature -10 to 50, storage:-25 to 65
ment Ambient humidity 35 to 85%RH, storage: 35 to 85%RH
Unit weight Approx. 196g Approx. 496g Approx. 399g Approx. 468g
F.S. is same with sensor measuring temperature range.
Ex) In case of measurement temperature range is from -99.9 to 199.9, Full scale is 299.8.
Environment resistance is rated at no freezing or condensation.

H-89
T3S/ T3H/ T4M/ T4L

Connections
RTD: DPt100 (3-wire type) Thermocouple: K, J, R

T3S T4M Although T4M has an alarm terminal,


it does not work since it uses the same
case with T4MA.
CONTACT OUT : SENSOR
250VAC 2A 1c RESISTIVE LOAD
T.C
SSR OUT :
12VDC 3V 20mA Max. RTD A B B'
CURRENT OUT :
DC4-20mA LOAD 600 Max. 8 9 10 11 12 13 14

C
ALARM OUT
4 5
L H
B'
3 6

B
2 7
1 8
SENSOR
L H
A 220VAC 110VAC
~ C 50/60Hz 50/60Hz 0V
T.C RTD
SOURCE 1 2 3 4 5 6 7
100-240VAC
50/60Hz 5VA CONTACT OUT: ~
250VAC 3A 1c
RESISTIVE LOAD ~
SSR OUT:
SOURCE
24VDC 3V
20mA Max.
CURRENT OUT:
DC4-20mA
LOAD 600 Max.

T3H T4L

SENSOR
0V CURRENT OUT: T.C RTD
1 DC4-20mA 1 CONTACT OUT: 18
~ LOAD 600 Max. L A
110VAC 50/60Hz C 250VAC 3A 1c
~ 2 10 2 RESISTIVE LOAD 17
SSR OUT:
220VAC 50/60Hz H 24VDC 3V
3 11 3 16
SOURCE 20mA Max. B
CURRENT OUT:
4 12 4 DC4-20mA 15
LOAD 600 Max. B'
5 13 5 14
SSR OUT: 6 14
24VDC 3V 6 13
20mA Max. 220VAC 50/60Hz
7 15 7 12
H B'
C 110VAC 50/60Hz
8 16 B 8 ~ SOURCE 11
~
L 0V
9 17 A 9 10
CONTACT OUT: RTD T.C
250VAC 3A 1c
RESISTIVE LOAD SENSOR

H-90
Standard type

Dimensions (unit: mm) (A)


Photo
electric
sensor

T3S
Panel cut-out (B)
Fiber
optic
sensor
48 12 73 15 Min. 55
<Bracket>
(C)
Door/Area
sensor

45 +0.6
0
(D)
Proximity

Min. 62
sensor

44.8
61
45 +0.6
0

(E)
Pressure
sensor

(F)
Socket: PG-08, PS-08(sold separately) Rotary
encoder

T3H Panel cut-out (G)


Connector/
Socket
48 12 134 Min. 50
(H)
Temp.
controller

(I)

92 +0.8
0
SSR/
Power
controller

Min. 102
(J)
100

Counter
96

91 45 +0.6
0

(K)
Timer

(L)
Panel
meter

(M)
Tacho/
T4M Speed/ Pulse
Panel cut-out meter

86 Min. 91 (N)
Display
72 13 112 unit

(O)

68 +0.7
Sensor

0
controller

(P)
Min. 91

Switching
mode power
68 +0.7 supply
67

(Q)
Stepper
motor&
Driver&Controller

(R)
Graphic/
Logic
panel

T4L Panel cut-out (S)


Field
96 18 100 Min. 116 network
device

(T)
Software
+0.8
920

(U)
Other
Min. 116
109

92 +0.8
90

H-91
T3S/ T3H/ T4M/ T4L

Proper usage
Using front adjuster T4M T3S

Lock

Open the front guide, turn it Pressing pin plug , raise


P.B adjuster Reset adjuster toward and pull toward , it up with a driver as and
it is detached. it is detached.
P.B adjuster
In case of ON/OFF control, set variable F.S. 0.2 to 3% of Application of temperature controller and
hysteresis and in case of P control, set variable F.S. 1 to load connection
10% of hysteresis. However, hysteresis(F.S. 0.5% 0.2%)
and proportional band(F.S. 3%) are fixed in T3S. SSR drive voltage output connection
Reset adjuster Temperature
controller SSR
It corrects offset can be occurred by P control and has F.S.
3% of adjustable range. Do not operate the adjuster when
SSR I
it is used as ON/OFF control. L Load
drive N
12VDC or 24VDC O
0 voltage 20mA Max. P A
Turn left when offset value is higher output U Load
D
than setting value. (Direction ) terminal T power
- +
-3% +3%
Turn right when offset value is lower
than setting value. (Direction )
RESET VR When using voltage(for driving SSR) in the other
purposes, do not over the range of the rated current.
Normal/Reverse operation Please aware that each Series has different voltage(for
driving SSR).
Reverse operation executes to output ON when process
value is lower than setting value and it is used for heating. Relay output connection
Normal operation runs conversely and is executed for
cooling. (This item runs as a reverse operation) Temperature
controller
Load

How to select control mode L Load


C power
Factory specification is P control. When using ON/OFF COM
control, transfer the switch of control method from P to F
after detaching the case from its body. When control output H
N.C Relay contact output terminal
is current output, P control is fixed, there is no switch Pin of
control method.
Be aware that each model has different contact capacity
of relay. When load capacity is high, please use sub
P F P F relay, which has high contact capacity.
P control ON/OFF control
Current output connection
Temperature
Case detachment controller Power controller

T4/T3H U
Load
Pressing the front Current
output DC4-20mA W
guide of Lock toward LOAD 600 Max.
terminal R
and squeeze and Load
pull toward , it is power
T
detached.

The current value of DC4-20mA is available at lower


than 600 of resistive load.

Refer to the H-141 page for caution for using and simple
error diagnosis.

H-92

You might also like