M SERIES PERKINS DIESEL GENERATING SETS

TECHNICAL SPECIFICATION
PERKINS POWERED GENERATOR SETS: M-P400
Quality Standards
Our diesel generating sets meets the following standards:
GB/T2820, GB1105, YD/T502, ISO3046, ISO8525, ISO8525-3-5-6.
Factory Test
Each our generating sets must be got through 1 hour load test for running 0%, 25%, 50%,75%,
100% and 110% load before dispatch, All protective devices, control functions are simulated
and its system checked, proved and then passed for dispatch. A test certificate can be
provided upon request.

MAIN SPECIFICATIONS OF GENERATOR SETS


Diesel Generator Set
GENSET MODEL NOS. M-P400

Rated speed / frequency 1500 rpm / 50 Hz


Continuous outputKW/KVA 280/350
Standby outputKW/KVA 320/400
Voltage, Phase and wire 400V/230V, 3 Phase and 4 Wires
Rated power factor 0.8lagging
Maximum output current(A) 505.1
Dimension(L*W*H) (mm) 3300X1140X1956
Weight(kg) 3300
Rating Definitions (Operation at Altitude 1000m, Ambient temperature 40)
Continuous Power
These ratings are applicable for supplying continuous electrical power (at variable load) in
lieu of commercially purchased power. There is no limitation to the annual hours of
operation and this model can supply 10% overload power for 1 hour in 12 hours.
Diesel Engine
DIESEL ENGINE MODEL 2306C-E14TAG2 (UK Perkins)

Engine Characters Water-cooled, 6 cylinders in line, 4-cycle, direct injection

The maximum outputkW 353


Aspiration Turbocharged
Bore(mm)Stroke (mm) 137X165
Fuel consumption(g/kw.h) 201in full load
Cubic Capacity (Liters) 14.6
Exhaust air flow(m3/min) 438
Compress air flow(m3/min) 32.2
Exhaust gas flow(m3/min) 79.1
Exhaust highest temperature 461

1
M SERIES PERKINS DIESEL GENERATING SETS

Lub-oil pan capacity(L) 68


Cooling water capacity(L) 47
Voltage for start(V) 24
Instrument for adjusting speed Electronically
Noise level(@7M) 92dBA(open)
ALTERNATOR
ALTERNATOR MODEL LSA 47.2VS2(Leroy Somer)
Excitation Brushless
Insulation class H
Protection class IP22
Efficiency 91.5%
Steady state voltage regulation 0.5%
Voltage Control AVR
Generating Set Control System
AC/DC control panel consisting of:
Emergency Stop button
Voltmeter and selector switch
Ammeter and selector switch
Frequency meter
Controller DSE702(Key start) or EMS39(Auto-start) with following (and not restricted to)
features:
Start/Stop button
Hour run meter
Monitor engine temperature and provides shutdown protection
Monitor engine speed and provides optional shutdown protection
Monitor oil pressure or level and provides shutdown protection
Alarm output for abnormal operation

Available Options:
----Weatherproof Canopy, Soundproof Canopy, Trailers, Automatic mains failure panel,
Manual transfer panel, Automatic transfer Panel, Fully Automatic Synchronizing and load
Sharing Panel, Manual Synchronizing Panel.

In line with our policy of continuous product development, we reserve our right to
change the above specifications without notice.

2
M SERIES PERKINS DIESEL GENERATING SETS

TECHNICAL SPECIFICATION
PERKINS POWERED GENERATOR SETS: M-P450
Quality Standards
Our diesel generating sets meets the following standards:
GB/T2820, GB1105, YD/T502, ISO3046, ISO8525, ISO8525-3-5-6.
Factory Test
Each our generating sets must be got through 1 hour load test for running 0%, 25%, 50%,75%,
100% and 110% load before dispatch, All protective devices, control functions are simulated
and its system checked, proved and then passed for dispatch. A test certificate can be
provided upon request.

MAIN SPECIFICATIONS OF GENERATOR SETS


Diesel Generator Set
GENSET MODEL NOS. M-P450

Rated speed / frequency 1500 rpm / 50 Hz


Continuous outputKW/KVA 320/400
Standby outputKW/KVA 360/450
Voltage, Phase and wire 400V/230V, 3 Phase and 4 Wires
Rated power factor 0.8lagging
Maximum output current(A) 577.4
Dimension(L*W*H) (mm) 3300X1140X1956
Weight(kg) 3300
Rating Definitions (Operation at Altitude 1000m, Ambient temperature 40)
Continuous Power
These ratings are applicable for supplying continuous electrical power (at variable load) in
lieu of commercially purchased power. There is no limitation to the annual hours of
operation and this model can supply 10% overload power for 1 hour in 12 hours.
Diesel Engine
DIESEL ENGINE MODEL 2306C-E14TAG3 (UK Perkins)

Engine Characters Water-cooled, 6 cylinders in line, 4-cycle, direct injection

The maximum outputkW 396


Aspiration Turbocharged
Bore(mm)Stroke (mm) 137X165
Fuel consumption(g/kw.h) 199in full load
Cubic Capacity (Liters) 14.6
Exhaust air flow(m3/min) 438
Compress air flow(m3/min) 34.6
Exhaust gas flow(m3/min) 86.6
Exhaust highest temperature 474

1
M SERIES PERKINS DIESEL GENERATING SETS

Lub-oil pan capacity(L) 68


Cooling water capacity(L) 47
Voltage for start(V) 24
Instrument for adjusting speed Electronically
Noise level(@7M) 92dBA(open)
ALTERNATOR
ALTERNATOR MODEL LSA 47.2S4(Leroy Somer)
Excitation Brushless
Insulation class H
Protection class IP22
Efficiency 91.5%
Steady state voltage regulation 0.5%
Voltage Control AVR
Generating Set Control System
AC/DC control panel consisting of:
Emergency Stop button
Voltmeter and selector switch
Ammeter and selector switch
Frequency meter
Controller DSE702(Key start) or EMS39(Auto-start) with following (and not restricted to)
features:
Start/Stop button
Hour run meter
Monitor engine temperature and provides shutdown protection
Monitor engine speed and provides optional shutdown protection
Monitor oil pressure or level and provides shutdown protection
Alarm output for abnormal operation

Available Options:
----Weatherproof Canopy, Soundproof Canopy, Trailers, Automatic mains failure panel,
Manual transfer panel, Automatic transfer Panel, Fully Automatic Synchronizing and load
Sharing Panel, Manual Synchronizing Panel.

In line with our policy of continuous product development, we reserve our right to
change the above specifications without notice.

2
M SERIES PERKINS DIESEL GENERATING SETS

TECHNICAL SPECIFICATION
PERKINS POWERED GENERATOR SETS: M-P500
Quality Standards
Our diesel generating sets meets the following standards:
GB/T2820, GB1105, YD/T502, ISO3046, ISO8525, ISO8525-3-5-6.
Factory Test
Each our generating sets must be got through 1 hour load test for running 0%, 25%, 50%,75%,
100% and 110% load before dispatch, All protective devices, control functions are simulated
and its system checked, proved and then passed for dispatch. A test certificate can be
provided upon request.

MAIN SPECIFICATIONS OF GENERATOR SETS


Diesel Generator Set
GENSET MODEL NOS. M-P500

Rated speed / frequency 1500 rpm / 50 Hz


Continuous outputKW/KVA 360/450
Standby outputKW/KVA 400/500
Voltage, Phase and wire 400V/230V, 3 Phase and 4 Wires
Rated power factor 0.8lagging
Maximum output current(A) 649.5
Dimension(L*W*H) (mm) 3430X1167X1956
Weight(kg) 3800
Rating Definitions (Operation at Altitude 1000m, Ambient temperature 40)
Continuous Power
These ratings are applicable for supplying continuous electrical power (at variable load) in
lieu of commercially purchased power. There is no limitation to the annual hours of
operation and this model can supply 10% overload power for 1 hour in 12 hours.
Diesel Engine
DIESEL ENGINE MODEL 2806C-E16TAG1 ( UK Perkins)

Engine Characters Water-cooled, 6 cylinders in line, 4-cycle, direct injection

The maximum outputkW 445


Aspiration Turbocharged
Bore(mm)Stroke (mm) 140X171
Fuel consumption(g/kw.h) 205 (in full Load)
Cubic Capacity (Liters) 15.8
Exhaust air flow(m3/min) 540
Compress air flow(m3/min) 38
Exhaust gas flow(m3/min) 83
Exhaust highest temperature 457

1
M SERIES PERKINS DIESEL GENERATING SETS

Lub-oil pan capacity(L) 68


Cooling water capacity(L) 50
Voltage for start(V) 24
Instrument for adjusting speed Electronically
Noise level(@7M) 95dBA
ALTERNATOR
ALTERNATOR MODEL LSA 47.2S5(Leroy Somer)
Excitation Brushless
Insulation class H
Protection class IP22
Efficiency 91.5%
Steady state voltage regulation 0.5%
Voltage Control AVR
Generating Set Control System
AC/DC control panel consisting of:
Emergency Stop button
Voltmeter and selector switch
Ammeter and selector switch
Frequency meter
Controller DSE702(Key start) or EMS39(Auto-start) with following (and not restricted to)
features:
Start/Stop button
Hour run meter
Monitor engine temperature and provides shutdown protection
Monitor engine speed and provides optional shutdown protection
Monitor oil pressure or level and provides shutdown protection
Alarm output for abnormal operation

Available Options:
----Weatherproof Canopy, Soundproof Canopy, Trailers, Automatic mains failure panel,
Manual transfer panel, Automatic transfer Panel, Fully Automatic Synchronizing and load
Sharing Panel, Manual Synchronizing Panel.

In line with our policy of continuous product development, we reserve our right to
change the above specifications without notice.

2
M SERIES PERKINS DIESEL GENERATING SETS

TECHNICAL SPECIFICATION
PERKINS POWERED GENERATOR SETS: M-P550
Quality Standards
Our diesel generating sets meets the following standards:
GB/T2820, GB1105, YD/T502, ISO3046, ISO8525, ISO8525-3-5-6.
Factory Test
Each our generating sets must be got through 1 hour load test for running 0%, 25%, 50%,75%,
100% and 110% load before dispatch, All protective devices, control functions are simulated
and its system checked, proved and then passed for dispatch. A test certificate can be
provided upon request.

MAIN SPECIFICATIONS OF GENERATOR SETS


Diesel Generator Set
GENSET MODEL NOS. M-P550

Rated speed / frequency 1500 rpm / 50 Hz


Continuous outputKW/KVA 400/500
Standby outputKW/KVA 440/550
Voltage, Phase and wire 400V/230V, 3 Phase and 4 Wires
Rated power factor 0.8lagging
Maximum output current(A) 721.7
Dimension(L*W*H) (mm) 3500X1167X1956
Weight(kg) 3940
Rating Definitions (Operation at Altitude 1000m, Ambient temperature 40)
Continuous Power
These ratings are applicable for supplying continuous electrical power (at variable load) in
lieu of commercially purchased power. There is no limitation to the annual hours of
operation and this model can supply 10% overload power for 1 hour in 12 hours.
Diesel Engine
DIESEL ENGINE MODEL 2806C-E16TAG2 ( UK Perkins)

Engine Characters Water-cooled, 6 cylinders in line, 4-cycle, direct injection

The maximum outputkW 483


Aspiration Turbocharged
Bore(mm)Stroke (mm) 140X171
Fuel consumption(g/kw.h) 203 (in full Load)
Cubic Capacity (Liters) 15.8
Exhaust air flow(m3/min) 540
Compress air flow(m3/min) 41.3
Exhaust gas flow(m3/min) 90
Exhaust highest temperature 459

1
M SERIES PERKINS DIESEL GENERATING SETS

Lub-oil pan capacity(L) 68


Cooling water capacity(L) 50
Voltage for start(V) 24
Instrument for adjusting speed Electronically
Noise level(@7M) 95dBA
ALTERNATOR
ALTERNATOR MODEL LSA 47.2M7(Leroy Somer)
Excitation Brushless
Insulation class H
Protection class IP22
Efficiency 91.5%
Steady state voltage regulation 0.5%
Voltage Control AVR
Generating Set Control System
AC/DC control panel consisting of:
Emergency Stop button
Voltmeter and selector switch
Ammeter and selector switch
Frequency meter
Controller DSE702(Key start) or EMS39(Auto-start) with following (and not restricted to)
features:
Start/Stop button
Hour run meter
Monitor engine temperature and provides shutdown protection
Monitor engine speed and provides optional shutdown protection
Monitor oil pressure or level and provides shutdown protection
Alarm output for abnormal operation

Available Options:
----Weatherproof Canopy, Soundproof Canopy, Trailers, Automatic mains failure panel,
Manual transfer panel, Automatic transfer Panel, Fully Automatic Synchronizing and load
Sharing Panel, Manual Synchronizing Panel.

In line with our policy of continuous product development, we reserve our right to
change the above specifications without notice.

2
M SERIES PERKINS DIESEL GENERATING SETS

TECHNICAL SPECIFICATION
PERKINS POWERED GENERATOR SETS: M-P625
Quality Standards
Our diesel generating sets meets the following standards:
GB/T2820, GB1105, YD/T502, ISO3046, ISO8525, ISO8525-3-5-6.
Factory Test
Each our generating sets must be got through 1 hour load test for running 0%, 25%, 50%,75%,
100% and 110% load before dispatch, All protective devices, control functions are simulated
and its system checked, proved and then passed for dispatch. A test certificate can be
provided upon request.

MAIN SPECIFICATIONS OF GENERATOR SETS


Diesel Generator Set
GENSET MODEL NOS. M-P625

Rated speed / frequency 1500 rpm / 50 Hz


Continuous outputKW/KVA 440/550
Standby outputKW/KVA 500/625
Voltage, Phase and wire 400V/230V, 3 Phase and 4 Wires
Rated power factor 0.8lagging
Maximum output current(A) 793.9
Dimension(L*W*H) (mm) 3245X1460X2197
Weight(kg) 3940
Rating Definitions (Operation at Altitude 1000m, Ambient temperature 40)
Continuous Power
These ratings are applicable for supplying continuous electrical power (at variable load) in
lieu of commercially purchased power. There is no limitation to the annual hours of
operation and this model can supply 10% overload power for 1 hour in 12 hours.
Diesel Engine
DIESEL ENGINE MODEL 2806C-E18TAG1 ( UK Perkins)

Engine Characters Water-cooled, 6 cylinders in line, 4-cycle, direct injection

The maximum outputkW 561


Aspiration Turbocharged
Bore(mm)Stroke (mm) 145X183
Fuel consumption(g/kw.h) 217.7 (in full Load)
Cubic Capacity (Liters) 18.1
Exhaust air flow(m3/min) 702
Compress air flow(m3/min) 45
Exhaust gas flow(m3/min) 129
Exhaust highest temperature 570

1
M SERIES PERKINS DIESEL GENERATING SETS

Lub-oil pan capacity(L) 55.5


Cooling water capacity(L) 61
Voltage for start(V) 24
Instrument for adjusting speed Electronically
Noise level(@7M) 95dBA
ALTERNATOR
ALTERNATOR MODEL LSA 47.2M8(Leroy Somer)
Excitation Brushless
Insulation class H
Protection class IP22
Efficiency 91.5%
Steady state voltage regulation 0.5%
Voltage Control AVR
Generating Set Control System
AC/DC control panel consisting of:
Emergency Stop button
Voltmeter and selector switch
Ammeter and selector switch
Frequency meter
Controller DSE702(Key start) or EMS39(Auto-start) with following (and not restricted to)
features:
Start/Stop button
Hour run meter
Monitor engine temperature and provides shutdown protection
Monitor engine speed and provides optional shutdown protection
Monitor oil pressure or level and provides shutdown protection
Alarm output for abnormal operation

Available Options:
----Weatherproof Canopy, Soundproof Canopy, Trailers, Automatic mains failure panel,
Manual transfer panel, Automatic transfer Panel, Fully Automatic Synchronizing and load
Sharing Panel, Manual Synchronizing Panel.

In line with our policy of continuous product development, we reserve our right to
change the above specifications without notice.

2
M SERIES PERKINS DIESEL GENERATING SETS

TECHNICAL SPECIFICATION
PERKINS POWERED GENERATOR SETS: M-P690
Quality Standards
Our diesel generating sets meets the following standards:
GB/T2820, GB1105, YD/T502, ISO3046, ISO8525, ISO8525-3-5-6.
Factory Test
Each our generating sets must be got through 1 hour load test for running 0%, 25%, 50%,75%,
100% and 110% load before dispatch, All protective devices, control functions are simulated
and its system checked, proved and then passed for dispatch. A test certificate can be
provided upon request.

MAIN SPECIFICATIONS OF GENERATOR SETS


Diesel Generator Set
GENSET MODEL NOS. M-P690

Rated speed / frequency 1500 rpm / 50 Hz


Continuous outputKW/KVA 500/625
Standby outputKW/KVA 550/690
Voltage, Phase and wire 400V/230V, 3 Phase and 4 Wires
Rated power factor 0.8lagging
Maximum output current(A) 902.1
Dimension(L*W*H) (mm) 3245X1460X2197
Weight(kg) 4706
Rating Definitions (Operation at Altitude 1000m, Ambient temperature 40)
Continuous Power
These ratings are applicable for supplying continuous electrical power (at variable load) in
lieu of commercially purchased power. There is no limitation to the annual hours of
operation and this model can supply 10% overload power for 1 hour in 12 hours.
Diesel Engine
DIESEL ENGINE MODEL 2806C-E18TAG2( UK Perkins)

Engine Characters Water-cooled, 6 cylinders in line, 4-cycle, direct injection

The maximum outputkW 607


Aspiration Turbocharged
Bore(mm)Stroke (mm) 145X183
Fuel consumption(g/kw.h) 202.4 (in full Load)
Cubic Capacity (Liters) 18.1
Exhaust air flow(m3/min) 702
Compress air flow(m3/min) 43
Exhaust gas flow(m3/min) 123
Exhaust highest temperature 563

1
M SERIES PERKINS DIESEL GENERATING SETS

Lub-oil pan capacity(L) 55.5


Cooling water capacity(L) 61
Voltage for start(V) 24
Instrument for adjusting speed Electronically
Noise level(@7M) 95dBA
ALTERNATOR
ALTERNATOR MODEL LSA 47.2L9(Leroy Somer)
Excitation Brushless
Insulation class H
Protection class IP22
Efficiency 91.5%
Steady state voltage regulation 0.5%
Voltage Control AVR
Generating Set Control System
AC/DC control panel consisting of:
Emergency Stop button
Voltmeter and selector switch
Ammeter and selector switch
Frequency meter
Controller DSE702(Key start) or EMS39(Auto-start) with following (and not restricted to)
features:
Start/Stop button
Hour run meter
Monitor engine temperature and provides shutdown protection
Monitor engine speed and provides optional shutdown protection
Monitor oil pressure or level and provides shutdown protection
Alarm output for abnormal operation

Available Options:
----Weatherproof Canopy, Soundproof Canopy, Trailers, Automatic mains failure panel,
Manual transfer panel, Automatic transfer Panel, Fully Automatic Synchronizing and load
Sharing Panel, Manual Synchronizing Panel.

In line with our policy of continuous product development, we reserve our right to
change the above specifications without notice.

2
M SERIES PERKINS DIESEL GENERATING SETS

TECHNICAL SPECIFICATION
PERKINS POWERED GENERATOR SETS: M-P725
Quality Standards
Our diesel generating sets meets the following standards:
GB/T2820, GB1105, YD/T502, ISO3046, ISO8525, ISO8525-3-5-6.
Factory Test
Each our generating sets must be got through 1 hour load test for running 0%, 25%, 50%,75%,
100% and 110% load before dispatch, All protective devices, control functions are simulated
and its system checked, proved and then passed for dispatch. A test certificate can be
provided upon request.

MAIN SPECIFICATIONS OF GENERATOR SETS


Diesel Generator Set
GENSET MODEL NOS. M-P725

Rated speed / frequency 1500 rpm / 50 Hz


Continuous outputKW/KVA 520/650
Standby outputKW/KVA 580/725
Voltage, Phase and wire 400V/230V, 3 Phase and 4 Wires
Rated power factor 0.8lagging
Maximum output current(A) 938.2
Dimension(L*W*H) (mm) 4140*1700*2150
Weight(kg) 4706
Rating Definitions (Operation at Altitude 1000m, Ambient temperature 40)
Continuous Power
These ratings are applicable for supplying continuous electrical power (at variable load) in
lieu of commercially purchased power. There is no limitation to the annual hours of
operation and this model can supply 10% overload power for 1 hour in 12 hours.
Diesel Engine
DIESEL ENGINE MODEL 4006-23TAG1A ( UK Perkins)

Engine Characters Water-cooled, 6 cylinders in line, 4-cycle, direct injection

The maximum outputkW 646


Aspiration Turbocharged
Bore(mm)Stroke (mm) 160X190
Fuel consumption(g/kw.h) 203 (in full load)
Cubic Capacity (Liters) 22.92
Exhaust air flow(m3/min) 1200
Compress air flow(m3/min) 64
Exhaust gas flow(m3/min) 171
Exhaust highest temperature 410

1
M SERIES PERKINS DIESEL GENERATING SETS

Lub-oil pan capacity(L) 113.4


Cooling water capacity(L) 105
Voltage for start(V) 24
Instrument for adjusting speed Electronically
Noise level(@7M) 95dBA(open)
ALTERNATOR
ALTERNATOR MODEL LSA 49.1S4 (Leroy Somer)
Excitation Brushless
Insulation class H
Protection class IP23
Efficiency 91.5%
Steady state voltage regulation 0.5%
Voltage Control AVR
Generating Set Control System
AC/DC control panel consisting of:
Emergency Stop button
Voltmeter and selector switch
Ammeter and selector switch
Frequency meter
Controller DSE702(Key start) or EMS39(Auto-start) with following (and not restricted to)
features:
Start/Stop button
Hour run meter
Monitor engine temperature and provides shutdown protection
Monitor engine speed and provides optional shutdown protection
Monitor oil pressure or level and provides shutdown protection
Alarm output for abnormal operation

Available Options:
----Weatherproof Canopy, Soundproof Canopy, Trailers, Automatic mains failure panel,
Manual transfer panel, Automatic transfer Panel, Fully Automatic Synchronizing and load
Sharing Panel, Manual Synchronizing Panel.

In line with our policy of continuous product development, we reserve our right to
change the above specifications without notice.

2
M SERIES PERKINS DIESEL GENERATING SETS

TECHNICAL SPECIFICATION
PERKINS POWERED GENERATOR SETS: M-P800
Quality Standards
Our diesel generating sets meets the following standards:
GB/T2820, GB1105, YD/T502, ISO3046, ISO8525, ISO8525-3-5-6.
Factory Test
Each our generating sets must be got through 1 hour load test for running 0%, 25%, 50%,75%,
100% and 110% load before dispatch, All protective devices, control functions are simulated
and its system checked, proved and then passed for dispatch. A test certificate can be
provided upon request.

MAIN SPECIFICATIONS OF GENERATOR SETS


Diesel Generator Set
GENSET MODEL NOS. M-P800

Rated speed / frequency 1500 rpm / 50 Hz


Continuous outputKW/KVA 580/725
Standby outputKW/KVA 640/800
Voltage, Phase and wire 400V/230V, 3 Phase and 4 Wires
Rated power factor 0.8lagging
Maximum output current(A) 1046.5
Dimension(L*W*H) (mm) 4200*1700*2150
Weight(kg) 4706
Rating Definitions (Operation at Altitude 1000m, Ambient temperature 40)
Continuous Power
These ratings are applicable for supplying continuous electrical power (at variable load) in
lieu of commercially purchased power. There is no limitation to the annual hours of
operation and this model can supply 10% overload power for 1 hour in 12 hours.
Diesel Engine
DIESEL ENGINE MODEL 4006-23TAG2A ( UK Perkins)

Engine Characters Water-cooled, 6 cylinders in line, 4-cycle, direct injection

The maximum outputkW 711


Aspiration Turbocharged
Bore(mm)Stroke (mm) 160X190
Fuel consumption(g/kw.h) 203 (in full load)
Cubic Capacity (Liters) 22.92
Exhaust air flow(m3/min) 1200
Compress air flow(m3/min) 71
Exhaust gas flow(m3/min) 180
Exhaust highest temperature 430

1
M SERIES PERKINS DIESEL GENERATING SETS

Lub-oil pan capacity(L) 113.4


Cooling water capacity(L) 105
Voltage for start(V) 24
Instrument for adjusting speed Electronically
Noise level(@7M) 95dBA(open)
ALTERNATOR
ALTERNATOR MODEL LSA 49.1M6 (Leroy Somer)
Excitation Brushless
Insulation class H
Protection class IP23
Efficiency 91.5%
Steady state voltage regulation 0.5%
Voltage Control AVR
Generating Set Control System
AC/DC control panel consisting of:
Emergency Stop button
Voltmeter and selector switch
Ammeter and selector switch
Frequency meter
Controller DSE702(Key start) or EMS39(Auto-start) with following (and not restricted to)
features:
Start/Stop button
Hour run meter
Monitor engine temperature and provides shutdown protection
Monitor engine speed and provides optional shutdown protection
Monitor oil pressure or level and provides shutdown protection
Alarm output for abnormal operation

Available Options:
----Weatherproof Canopy, Soundproof Canopy, Trailers, Automatic mains failure panel,
Manual transfer panel, Automatic transfer Panel, Fully Automatic Synchronizing and load
Sharing Panel, Manual Synchronizing Panel.

In line with our policy of continuous product development, we reserve our right to
change the above specifications without notice.

2
M SERIES PERKINS DIESEL GENERATING SETS

TECHNICAL SPECIFICATION
PERKINS POWERED GENERATOR SETS: M-P900
Quality Standards
Our diesel generating sets meets the following standards:
GB/T2820, GB1105, YD/T502, ISO3046, ISO8525, ISO8525-3-5-6.
Factory Test
Each our generating sets must be got through 1 hour load test for running 0%, 25%, 50%,75%,
100% and 110% load before dispatch, All protective devices, control functions are simulated
and its system checked, proved and then passed for dispatch. A test certificate can be
provided upon request.

MAIN SPECIFICATIONS OF GENERATOR SETS


Diesel Generator Set
GENSET MODEL NOS. M-P900

Rated speed / frequency 1500 rpm / 50 Hz


Continuous outputKW/KVA 640/800
Standby outputKW/KVA 720/900
Voltage, Phase and wire 400V/230V, 3 Phase and 4 Wires
Rated power factor 0.8lagging
Maximum output current(A) 1154.7
Dimension(L*W*H) (mm) 4200*1700*2150
Weight(kg) 4706
Rating Definitions (Operation at Altitude 1000m, Ambient temperature 40)
Continuous Power
These ratings are applicable for supplying continuous electrical power (at variable load) in
lieu of commercially purchased power. There is no limitation to the annual hours of
operation and this model can supply 10% overload power for 1 hour in 12 hours.
Diesel Engine
DIESEL ENGINE MODEL 4006-23TAG3A ( UK Perkins)

Engine Characters Water-cooled, 6 cylinders in line, 4-cycle, direct injection

The maximum outputkW 786


Aspiration Turbocharged
Bore(mm)Stroke (mm) 160X190
Fuel consumption(g/kw.h) 203 (in full load)
Cubic Capacity (Liters) 22.92
Exhaust air flow(m3/min) 1200
Compress air flow(m3/min) 73
Exhaust gas flow(m3/min) 193
Exhaust highest temperature 500

1
M SERIES PERKINS DIESEL GENERATING SETS

Lub-oil pan capacity(L) 113.4


Cooling water capacity(L) 105
Voltage for start(V) 24
Instrument for adjusting speed Electronically
Noise level(@7M) 95dBA(open)
ALTERNATOR
ALTERNATOR MODEL LSA 49.1M75 (Leroy Somer)
Excitation Brushless
Insulation class H
Protection class IP23
Efficiency 91.5%
Steady state voltage regulation 0.5%
Voltage Control AVR
Generating Set Control System
AC/DC control panel consisting of:
Emergency Stop button
Voltmeter and selector switch
Ammeter and selector switch
Frequency meter
Controller DSE702(Key start) or EMS39(Auto-start) with following (and not restricted to)
features:
Start/Stop button
Hour run meter
Monitor engine temperature and provides shutdown protection
Monitor engine speed and provides optional shutdown protection
Monitor oil pressure or level and provides shutdown protection
Alarm output for abnormal operation

Available Options:
----Weatherproof Canopy, Soundproof Canopy, Trailers, Automatic mains failure panel,
Manual transfer panel, Automatic transfer Panel, Fully Automatic Synchronizing and load
Sharing Panel, Manual Synchronizing Panel.

In line with our policy of continuous product development, we reserve our right to
change the above specifications without notice.

2
M SERIES PERKINS DIESEL GENERATING SETS

TECHNICAL SPECIFICATION
PERKINS POWERED GENERATOR SETS: M-P1100
Quality Standards
Our diesel generating sets meets the following standards:
GB/T2820, GB1105, YD/T502, ISO3046, ISO8525, ISO8525-3-5-6.
Factory Test
Each our generating sets must be got through 1 hour load test for running 0%, 25%, 50%,75%,
100% and 110% load before dispatch, All protective devices, control functions are simulated
and its system checked, proved and then passed for dispatch. A test certificate can be
provided upon request.

MAIN SPECIFICATIONS OF GENERATOR SETS


Diesel Generator Set
GENSET MODEL NOS. M-P1100

Rated speed / frequency 1500 rpm / 50 Hz


Continuous outputKW/KVA 800/1023
Standby outputKW/KVA 880/1100
Voltage, Phase and wire 400V/230V, 3 Phase and 4 Wires
Rated power factor 0.8lagging
Maximum output current(A) 1476.6
Dimension(L*W*H) (mm) 4750*1870*2360
Weight(kg) 7611
Rating Definitions (Operation at Altitude 1000m, Ambient temperature 40)
Continuous Power
These ratings are applicable for supplying continuous electrical power (at variable load) in
lieu of commercially purchased power. There is no limitation to the annual hours of
operation and this model can supply 10% overload power for 1 hour in 12 hours.
Diesel Engine
DIESEL ENGINE MODEL 4008-TAG2A ( UK Perkins)

Engine Characters Water-cooled, 8 cylinders in line, 4-cycle, direct injection

The maximum outputkW 985


Aspiration Turbocharged
Bore(mm)Stroke (mm) 160X190
Fuel consumption(g/kw.h) 214 (in full load)
Cubic Capacity (Liters) 30.56
Exhaust air flow(m3/min) 1110
Compress air flow(m3/min) 80.5
Exhaust gas flow(m3/min) 200
Exhaust highest temperature 465

1
M SERIES PERKINS DIESEL GENERATING SETS

Lub-oil pan capacity(L) 149


Cooling water capacity(L) 153
Voltage for start(V) 24
Instrument for adjusting speed Electronically
Noise level(@7M) 102dBA(open)
ALTERNATOR
ALTERNATOR MODEL LSG55(Leroy Somer)
Excitation Brushless
Insulation class H
Protection class IP23
Efficiency 91.5%
Steady state voltage regulation 0.5%
Voltage Control AVR
Generating Set Control System
AC/DC control panel consisting of:
Emergency Stop button
Voltmeter and selector switch
Ammeter and selector switch
Frequency meter
Controller DSE702(Key start) or EMS39(Auto-start) with following (and not restricted to)
features:
Start/Stop button
Hour run meter
Monitor engine temperature and provides shutdown protection
Monitor engine speed and provides optional shutdown protection
Monitor oil pressure or level and provides shutdown protection
Alarm output for abnormal operation

Available Options:
----Weatherproof Canopy, Soundproof Canopy, Trailers, Automatic mains failure panel,
Manual transfer panel, Automatic transfer Panel, Fully Automatic Synchronizing and load
Sharing Panel, Manual Synchronizing Panel.

In line with our policy of continuous product development, we reserve our right to
change the above specifications without notice.

2
M SERIES PERKINS DIESEL GENERATING SETS

TECHNICAL SPECIFICATION
PERKINS POWERED GENERATOR SETS: M-P1375
Quality Standards
Our diesel generating sets meets the following standards:
GB/T2820, GB1105, YD/T502, ISO3046, ISO8525, ISO8525-3-5-6.
Factory Test
Each our generating sets must be got through 1 hour load test for running 0%, 25%, 50%,75%,
100% and 110% load before dispatch, All protective devices, control functions are simulated
and its system checked, proved and then passed for dispatch. A test certificate can be
provided upon request.

MAIN SPECIFICATIONS OF GENERATOR SETS


Diesel Generator Set
GENSET MODEL NOS. M-P1375

Rated speed / frequency 1500 rpm / 50 Hz


Continuous outputKW/KVA 1000/1250
Standby outputKW/KVA 1100/1375
Voltage, Phase and wire 400V/230V, 3 Phase and 4 Wires
Rated power factor 0.8lagging
Maximum output current(A) 1804.3
Dimension(L*W*H) (mm) 4800*1870*2570
Weight(kg) 9154
Rating Definitions (Operation at Altitude 1000m, Ambient temperature 40)
Continuous Power
These ratings are applicable for supplying continuous electrical power (at variable load) in
lieu of commercially purchased power. There is no limitation to the annual hours of
operation and this model can supply 10% overload power for 1 hour in 12 hours.
Diesel Engine
DIESEL ENGINE MODEL 4012TWG2( UK Perkins)
Water-cooled, 12 cylinders V-line, 4-cycle, direct
Engine Characters
injection
The maximum outputkW 1207
Aspiration Turbocharged
Bore(mm)Stroke (mm) 160X190
Fuel consumption(g/kw.h) 207 (in full load)
Cubic Capacity (Liters) 45.84
Engine coolant flow l/s 15.7
Compress air flow(m3/min) 97
Exhaust gas flow(m3/min) 245
Exhaust highest temperature 460

1
M SERIES PERKINS DIESEL GENERATING SETS

Lub-oil pan capacity(L) 205


Cooling water capacity(L) 159
Voltage for start(V) 24
Instrument for adjusting speed Electronically
Noise level(@7M) 102dBA(open)
ALTERNATOR
ALTERNATOR MODEL LVI634G(Stamford)
Excitation Brushless
Insulation class H
Protection class IP22
Efficiency 91.5%
Steady state voltage regulation 0.5%
Voltage Control AVR
Generating Set Control System
AC/DC control panel consisting of:
Emergency Stop button
Voltmeter and selector switch
Ammeter and selector switch
Frequency meter
Controller DSE702(Key start) or EMS39(Auto-start) with following (and not restricted to)
features:
Start/Stop button
Hour run meter
Monitor engine temperature and provides shutdown protection
Monitor engine speed and provides optional shutdown protection
Monitor oil pressure or level and provides shutdown protection
Alarm output for abnormal operation

Available Options:
----Weatherproof Canopy, Soundproof Canopy, Trailers, Automatic mains failure panel,
Manual transfer panel, Automatic transfer Panel, Fully Automatic Synchronizing and load
Sharing Panel, Manual Synchronizing Panel.

In line with our policy of continuous product development, we reserve our right to
change the above specifications without notice.

2
M SERIES PERKINS DIESEL GENERATING SETS

TECHNICAL SPECIFICATION
PERKINS POWERED GENERATOR SETS: M-P1550
Quality Standards
Our diesel generating sets meets the following standards:
GB/T2820, GB1105, YD/T502, ISO3046, ISO8525, ISO8525-3-5-6.
Factory Test
Each our generating sets must be got through 1 hour load test for running 0%, 25%, 50%,75%,
100% and 110% load before dispatch, All protective devices, control functions are simulated
and its system checked, proved and then passed for dispatch. A test certificate can be
provided upon request.

MAIN SPECIFICATIONS OF GENERATOR SETS


Diesel Generator Set
GENSET MODEL NOS. M-P1550

Rated speed / frequency 1500 rpm / 50 Hz


Continuous outputKW/KVA 1100/1375
Standby outputKW/KVA 1240/1550
Voltage, Phase and wire 400V/230V, 3 Phase and 4 Wires
Rated power factor 0.8lagging
Maximum output current(A) 1984.7
Dimension(L*W*H) (mm) 5600*2250*2570
Weight(kg) 11580
Rating Definitions (Operation at Altitude 1000m, Ambient temperature 40)
Continuous Power
These ratings are applicable for supplying continuous electrical power (at variable load) in
lieu of commercially purchased power. There is no limitation to the annual hours of
operation and this model can supply 10% overload power for 1 hour in 12 hours.
Diesel Engine
DIESEL ENGINE MODEL 4012TAG1A( UK Perkins)
Water-cooled, 12 cylinders V-line, 4-cycle, direct
Engine Characters
injection
The maximum outputkW 1292
Aspiration Turbocharged
Bore(mm)Stroke (mm) 160X190
Fuel consumption(g/kw.h) 203 (in full load)
Cubic Capacity (Liters) 45.84
Engine coolant flow(l/s) 17
Compress air flow(m3/min) 108
Exhaust gas flow(m3/min) 270
Exhaust highest temperature 490

1
M SERIES PERKINS DIESEL GENERATING SETS

Lub-oil pan capacity(L) 159


Cooling water capacity(L) 235
Voltage for start(V) 24
Instrument for adjusting speed Electronically
Noise level(@7M) 102dBA(open)
ALTERNATOR
ALTERNATOR MODEL PI734B(Stamford)
Excitation Brushless
Insulation class H
Protection class IP22
Efficiency 91.5%
Steady state voltage regulation 0.5%
Voltage Control AVR
Generating Set Control System
AC/DC control panel consisting of:
Emergency Stop button
Voltmeter and selector switch
Ammeter and selector switch
Frequency meter
Controller DSE702(Key start) or EMS39(Auto-start) with following (and not restricted to)
features:
Start/Stop button
Hour run meter
Monitor engine temperature and provides shutdown protection
Monitor engine speed and provides optional shutdown protection
Monitor oil pressure or level and provides shutdown protection
Alarm output for abnormal operation

Available Options:
----Weatherproof Canopy, Soundproof Canopy, Trailers, Automatic mains failure panel,
Manual transfer panel, Automatic transfer Panel, Fully Automatic Synchronizing and load
Sharing Panel, Manual Synchronizing Panel.

In line with our policy of continuous product development, we reserve our right to
change the above specifications without notice.

2
M SERIES PERKINS DIESEL GENERATING SETS

TECHNICAL SPECIFICATION
PERKINS POWERED GENERATOR SETS: M-P1650
Quality Standards
Our diesel generating sets meets the following standards:
GB/T2820, GB1105, YD/T502, ISO3046, ISO8525, ISO8525-3-5-6.
Factory Test
Each our generating sets must be got through 1 hour load test for running 0%, 25%, 50%,75%,
100% and 110% load before dispatch, All protective devices, control functions are simulated
and its system checked, proved and then passed for dispatch. A test certificate can be
provided upon request.

MAIN SPECIFICATIONS OF GENERATOR SETS


Diesel Generator Set
GENSET MODEL NOS. M-P1650

Rated speed / frequency 1500 rpm / 50 Hz


Continuous outputKW/KVA 1200/1500
Standby outputKW/KVA 1320/1650
Voltage, Phase and wire 400V/230V, 3 Phase and 4 Wires
Rated power factor 0.8lagging
Maximum output current(A) 2165.1
Dimension(L*W*H) (mm) 5927*2300*3010
Weight(kg) 15430
Rating Definitions (Operation at Altitude 1000m, Ambient temperature 40)
Continuous Power
These ratings are applicable for supplying continuous electrical power (at variable load) in
lieu of commercially purchased power. There is no limitation to the annual hours of
operation and this model can supply 10% overload power for 1 hour in 12 hours.
Diesel Engine
DIESEL ENGINE MODEL 4012TAG2A( UK Perkins)
Water-cooled, 12 cylinders V-line, 4-cycle, direct
Engine Characters
injection
The maximum outputkW 1386
Aspiration Turbocharged
Bore(mm)Stroke (mm) 160X190
Fuel consumption(g/kw.h) 206 (in full load)
Cubic Capacity (Liters) 45.84
Engine coolant flow(l/s) 17
Compress air flow(m3/min) 110
Exhaust gas flow(m3/min) 290
Exhaust highest temperature 510

1
M SERIES PERKINS DIESEL GENERATING SETS

Lub-oil pan capacity(L) 159


Cooling water capacity(L) 235
Voltage for start(V) 24
Instrument for adjusting speed Electronically
Noise level(@7M) 102dBA(open)
ALTERNATOR
ALTERNATOR MODEL PI734C(Stamford)
Excitation Brushless
Insulation class H
Protection class IP22
Efficiency 91.5%
Steady state voltage regulation 0.5%
Voltage Control AVR
Generating Set Control System
AC/DC control panel consisting of:
Emergency Stop button
Voltmeter and selector switch
Ammeter and selector switch
Frequency meter
Controller DSE702(Key start) or EMS39(Auto-start) with following (and not restricted to)
features:
Start/Stop button
Hour run meter
Monitor engine temperature and provides shutdown protection
Monitor engine speed and provides optional shutdown protection
Monitor oil pressure or level and provides shutdown protection
Alarm output for abnormal operation

Available Options:
----Weatherproof Canopy, Soundproof Canopy, Trailers, Automatic mains failure panel,
Manual transfer panel, Automatic transfer Panel, Fully Automatic Synchronizing and load
Sharing Panel, Manual Synchronizing Panel.

In line with our policy of continuous product development, we reserve our right to
change the above specifications without notice.

2
M SERIES PERKINS DIESEL GENERATING SETS

TECHNICAL SPECIFICATION
PERKINS POWERED GENERATOR SETS: M-P1850
Quality Standards
Our diesel generating sets meets the following standards:
GB/T2820, GB1105, YD/T502, ISO3046, ISO8525, ISO8525-3-5-6.
Factory Test
Each our generating sets must be got through 1 hour load test for running 0%, 25%, 50%,75%,
100% and 110% load before dispatch, All protective devices, control functions are simulated
and its system checked, proved and then passed for dispatch. A test certificate can be
provided upon request.

MAIN SPECIFICATIONS OF GENERATOR SETS


Diesel Generator Set
GENSET MODEL NOS. M-P1850

Rated speed / frequency 1500 rpm / 50 Hz


Continuous outputKW/KVA 1320/1650
Standby outputKW/KVA 1452/1815
Voltage, Phase and wire 400V/230V, 3 Phase and 4 Wires
Rated power factor 0.8lagging
Maximum output current(A) 2381.6
Dimension(L*W*H) (mm) 5927*2300*3010
Weight(kg) 15430
Rating Definitions (Operation at Altitude 1000m, Ambient temperature 40)
Continuous Power
These ratings are applicable for supplying continuous electrical power (at variable load) in
lieu of commercially purchased power. There is no limitation to the annual hours of
operation and this model can supply 10% overload power for 1 hour in 12 hours.
Diesel Engine
DIESEL ENGINE MODEL 4016TAG ( UK Perkins)
Water-cooled, 16 cylinders V-line, 4-cycle, direct
Engine Characters
injection
The maximum outputkW 1649
Aspiration Turbocharged
Bore(mm)Stroke (mm) 160X190
Fuel consumption(g/kw.h) 206 (in full load)
Cubic Capacity (Liters) 61.12
Exhaust air flow(m3/min) 1916
Compress air flow(m3/min) 146
Exhaust gas flow(m3/min) 379
Exhaust highest temperature 480

1
M SERIES PERKINS DIESEL GENERATING SETS

Lub-oil pan capacity(L) 215


Cooling water capacity(L) 300
Voltage for start(V) 24
Instrument for adjusting speed Electronically
Noise level(@7M) 102dBA(open)
ALTERNATOR
ALTERNATOR MODEL PI734D(Stamford)
Excitation Brushless
Insulation class H
Protection class IP22
Efficiency 91.5%
Steady state voltage regulation 0.5%
Voltage Control AVR
Generating Set Control System
AC/DC control panel consisting of:
Emergency Stop button
Voltmeter and selector switch
Ammeter and selector switch
Frequency meter
Controller DSE702(Key start) or EMS39(Auto-start) with following (and not restricted to)
features:
Start/Stop button
Hour run meter
Monitor engine temperature and provides shutdown protection
Monitor engine speed and provides optional shutdown protection
Monitor oil pressure or level and provides shutdown protection
Alarm output for abnormal operation

Available Options:
----Weatherproof Canopy, Soundproof Canopy, Trailers, Automatic mains failure panel,
Manual transfer panel, Automatic transfer Panel, Fully Automatic Synchronizing and load
Sharing Panel, Manual Synchronizing Panel.

In line with our policy of continuous product development, we reserve our right to
change the above specifications without notice.

2
M SERIES PERKINS DIESEL GENERATING SETS

TECHNICAL SPECIFICATION
PERKINS POWERED GENERATOR SETS: M-P2250
Quality Standards
Our diesel generating sets meets the following standards:
GB/T2820, GB1105, YD/T502, ISO3046, ISO8525, ISO8525-3-5-6.
Factory Test
Each our generating sets must be got through 1 hour load test for running 0%, 25%, 50%,75%,
100% and 110% load before dispatch, All protective devices, control functions are simulated
and its system checked, proved and then passed for dispatch. A test certificate can be
provided upon request.

MAIN SPECIFICATIONS OF GENERATOR SETS


Diesel Generator Set
GENSET MODEL NOS. M-P2250

Rated speed / frequency 1500 rpm / 50 Hz


Continuous outputKW/KVA 1640/2050
Standby outputKW/KVA 1800/2250
Voltage, Phase and wire 400V/230V, 3 Phase and 4 Wires
Rated power factor 0.8lagging
Maximum output current(A) 2959
Dimension(L*W*H) (mm) 6011*2280*3010
Weight(kg) 15500
Rating Definitions (Operation at Altitude 1000m, Ambient temperature 40)
Continuous Power
These ratings are applicable for supplying continuous electrical power (at variable load) in
lieu of commercially purchased power. There is no limitation to the annual hours of
operation and this model can supply 10% overload power for 1 hour in 12 hours.
Diesel Engine
DIESEL ENGINE MODEL 4016TAG2A( UK Perkins)
Water-cooled, 16 cylinders V-line, 4-cycle, direct
Engine Characters
injection
The maximum outputkW 1890
Aspiration Turbocharged
Bore(mm)Stroke (mm) 160X190
Fuel consumption(g/kw.h) 212(in full load)
Cubic Capacity (Liters) 61.1
Engine coolant flow(l/s) 19
Compress air flow(m3/min) 145
Exhaust gas flow(m3/min) 393
Exhaust highest temperature 493

1
M SERIES PERKINS DIESEL GENERATING SETS

Lub-oil pan capacity(L) 214


Cooling water capacity(L) 316
Voltage for start(V) 24
Instrument for adjusting speed Electronically
Noise level(@7M) 102dBA(open)
ALTERNATOR
ALTERNATOR MODEL PI734F(Stamford)
Excitation Brushless
Insulation class H
Protection class IP22
Efficiency 91.5%
Steady state voltage regulation 0.5%
Voltage Control AVR
Generating Set Control System
AC/DC control panel consisting of:
Emergency Stop button
Voltmeter and selector switch
Ammeter and selector switch
Frequency meter
Controller DSE702(Key start) or EMS39(Auto-start) with following (and not restricted to)
features:
Start/Stop button
Hour run meter
Monitor engine temperature and provides shutdown protection
Monitor engine speed and provides optional shutdown protection
Monitor oil pressure or level and provides shutdown protection
Alarm output for abnormal operation

Available Options:
----Weatherproof Canopy, Soundproof Canopy, Trailers, Automatic mains failure panel,
Manual transfer panel, Automatic transfer Panel, Fully Automatic Synchronizing and load
Sharing Panel, Manual Synchronizing Panel.

In line with our policy of continuous product development, we reserve our right to
change the above specifications without notice.