You are on page 1of 10

Training Units and Addressing

SIMATIC S7 Date: 18.09.2009 SITRAIN Training for


Automation and Industrial Solutions
Siemens AG 2008. All rights reserved. File: PRO1_02E.1

Contents Page
Training Area Setup with S7 - 300 .................................................................................................... 2
Configuration of the S7 - 300 Training Unit ....................................................................................... 3
The Simulator ................................................................................................................................... 4
The Conveyor Model ........................................................................................................................ 5
Complete Symbol List ................................................................................................................. 6
If You Want to Know More ................................................................................................................ 8
Training Area Setup with S7- 400 ..................................................................................................... 9
Configuration of the S7-400 Training Unit ......................................................................................... 10

SITRAIN Training for ST-PRO1


Automation and Industrial Solutions Page 1 Training Units and Addressing
Training Area Setup with S7 - 300

SIMATIC S7 Date: 18.09.2009 SITRAIN Training for


Automation and Industrial Solutions
Siemens AG 2008. All rights reserved. File: PRO1_02E.2

S7 - 300 Training Area The training area consists of the following components:
An S7-300 programmable logic controller with the CPU 315-2 DP
Digital input and output modules, analog module
Simulator with digital and analog sections
Conveyor model
ET 200S distributed peripheral
MM420 Micromaster with PROFIBUS module
TP170B Touchpanel
Programming device or PC

SITRAIN Training for ST-PRO1


Automation and Industrial Solutions Page 2 Training Units and Addressing
Configuration of the S7 - 300 Training Unit

Module --> PS CPU DI 32 DO 32 DI8/DO8 AI 2

Slot No. --> 1 2 4 5 6 7

I/O Address --> 0 4 8 304

SIMATIC S7 Date: 18.09.2009 SITRAIN Training for


Automation and Industrial Solutions
Siemens AG 2008. All rights reserved. File: PRO1_02E.3

Configuration The programmable controller is configured with the following modules:

Slot 1: Power Supply 24V/5A


Slot 2: CPU 315-2 DP
Slot 4: Digital input 32x24V Inputs from the simulator
and thumbwheel buttons
Slot 5: Digital output 32x24V/0.5A Outputs from the simulator
and digital display
Slot 6: Digital input and output Conveyor model
module 8X24V/ 8x24V 0.5A
Slot 7: Analog input 2 AI Analog section from the simulator

Addresses You can set the starting addresses of the modules by parameter assignment
(freely).

SITRAIN Training for ST-PRO1


Automation and Industrial Solutions Page 3 Training Units and Addressing
The Simulator
Potentiometers for
setting the
BCD Digital Display analog values
"QW_DigDisp" (QW 6) "PIW_AI1" (PIW 304)

DI DO

.0 .......... .......... .0
.1 .......... .......... .1
.2 .......... .......... .2
.3 .......... .......... .3 V
.4 .......... .......... .4
.5 .......... .......... .5
.6 .......... .......... .6 -15V...+15V AI2 AO1 -15V...+15V
AI1 AO2
.7 .......... .......... .7
.0 .......... ..........
.0
.1 .......... ..........
.1 AI1 AI2
.2 .......... .......... V
.2
.3 .......... ..........
.3
.4 .......... ..........
.5 .......... ..........
.4
.5
0 8 1 5 AI1 AI2 AO1 AO2
.6 .......... ..........
.6
.7 .......... ..........
.7

Switches LEDs Thumbwheel Buttons


/ Momentary Contact Switches (QW 4) "IW_Thumbw" (IW 2)
(IW 0)

SIMATIC S7 Date: 18.09.2009 SITRAIN Training for


Automation and Industrial Solutions
Siemens AG 2008. All rights reserved. File: PRO1_02E.4

Design Two cables connect the simulator to the S7-300 or S7-400 training unit. The
simulator is divided into the following three sections:

Binary section with 16 switches / momentary contact switches and 16 LEDs

Digital section with 4 thumbwheel buttons and a digital display. The


thumbwheel and digital (BCD) display use BCD values,

Analog section with two potentiometers for specifying or simulating analog


input signals and a voltmeter that selectable per switch displays the
voltage output set on the potentiometers or from the two output channels of
the analog output module (as far as it exists).

Addressing You use the following addresses to address the inputs and outputs in your user
program:

Sensor / Actuator (DI32, DO32)

Switch / Mom.Cont. IW 0

LEDs QW 4

Thumb. buttons IW 2

Digital display QW 6

Analog channels PIW 304/306

SITRAIN Training for ST-PRO1


Automation and Industrial Solutions Page 4 Training Units and Addressing
The Conveyor Model

"K_Conv_RIGHT" (Q 8.5) "BAY1" "BAY2" "BAY3" "LB" "Horn"


"K_Conv_LEFT" (Q 8.6) (I 8.5) (I 8.6) (I 8.7) (I 8.0) (Q 8.7)

"T_Bay1" "T_Bay2" "T_Bay3" "T_Bay-LB"


(I 8.1) (I 8.2) (I 8.3) (I 8.4)
"L_Bay1" "L_Bay2" "L_Bay3" "L_Bay-LB"
(Q 8.1) (Q 8.2) (Q 8.3) (Q 8.4)

SIMATIC S7 Date: 18.09.2009 SITRAIN Training for


Automation and Industrial Solutions
Siemens AG 2008. All rights reserved. File: PRO1_02E.5

Design The slide above shows the conveyor model with its sensors and actuators as
well as the assigned I/O addresses.

SITRAIN Training for ST-PRO1


Automation and Industrial Solutions Page 5 Training Units and Addressing
Complete Symbol List

SITRAIN Training for ST-PRO1


Automation and Industrial Solutions Page 6 Training Units and Addressing
Complete Symbol List (Continuation)

SITRAIN Training for ST-PRO1


Automation and Industrial Solutions Page 7 Training Units and Addressing
If You Want to Know More

SIMATIC S7 Date: 18.09.2009 SITRAIN Training for


Automation and Industrial Solutions
Siemens AG 2008. All rights reserved. File: PRO1_02E.8

Note The following pages contain either further information or are for reference to
complete a topic.

SITRAIN Training for ST-PRO1


Automation and Industrial Solutions Page 8 Training Units and Addressing
Training Area Setup with S7- 400

SIMATIC S7 Date: 18.09.2009 SITRAIN Training for


Automation and Industrial Solutions
Siemens AG 2008. All rights reserved. File: PRO1_02E.9

Contents of the The training area consists of the following components:


Training Area An S7-400 programmable logic controller with a CPU 412 or CPU 413-2 DP
Digital input and output modules, analog module
Simulator with digital and analog section
Conveyor model
ET 200S distributed peripheral
MM420 Micromaster with PROFIBUS module
TP170B Touchpanel
Programming device or PC

SITRAIN Training for ST-PRO1


Automation and Industrial Solutions Page 9 Training Units and Addressing
Configuration of the S7-400 Training Unit

Slot No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18

PS CPU DI DI DO DO AI
32 32 32 32 8

SIMATIC S7 Date: 18.09.2009 SITRAIN Training for


Automation and Industrial Solutions
Siemens AG 2008. All rights reserved. File: PRO1_02E.10

Design You can see the design of the S7-400 training unit in the slide above.

Configuration The UR 1 rack is configured with the following modules:


Slot 1: Power Supply 24V and 5V/20A
Slot 2: -"-
Slot 3: -"-
Slot 4: CPU 412 or other
Slot 5: vacant (when the CPU only has a single width)
Slot 6: vacant
Slot 7: vacant
Slot 8: Digital input 32x24V (from simulator)
Slot 9: Digital input 32x24V (from conveyor model)
Slot 10: Digital output 32x24V 0.5A (to simulator)
Slot 11: Digital output 32x24V 0.5A (to conveyor model)
Slot 12: Analog input 8x13 Bit (from potentiometer on simulator)
Slot 13: vacant
Slot 14: vacant
Slot 15: vacant
Slot 16: vacant
Slot 17: vacant
Slot 18: vacant

Addressing As long as no configuration or parameter settings have been made, the system
works with default addresses.

SITRAIN Training for ST-PRO1


Automation and Industrial Solutions Page 10 Training Units and Addressing