DESIGN OF PILECAP FOR PC-2

Load on one pile: 100 tonnes


No. of piles: 5
Length of pile cap: 3.3 m
Width of pile cap: 2.25 m
Depth of pilecap: 1400 mm
(effective)

Area of steel from Bending moment criteria

Bending moment considered along X-X:

Total number of piles contributing to Bending moment: 2

Piles along
Length L1,L2,L3
Row 1 L1: 0.725 m 2
Row 2 L2: 0 m 0
Row 3 L3: 0 m 0
L1,L2 and L3 is te distance column face to centre of pile row

Bending moment at the face of column (X-X) = 145 t-m

Bending moment per m width = 64.44444 t-m/m

Mu / bd2 =
0.493197

Percentage of steel from SP16 for M25 concrete = 0.2 %

Area of steel = 28 cm2/m

Bending moment considered along Y-Y:

Total number of piles contributing to Bending moment: 0

Piles along
Length L4,L5,L6
L4: 0 m 0
L5: 0 m 0
L6: 0 m 0
Bending moment at the face of column (Y-Y) = 0 t-m

Bending moment per m width = 0 t-m/m

Mu / bd2 =
0

Percentage of steel from SP16 for M30 concrete = 0.185 %

Area of steel = 25.9 cm2/m

Area of steel from shear consideration:

The critical section for shear is at d/2 from the face of column:

Shear considered at d/2 from face X-X:

Total number of piles contributing to shear = 2

Shear force = 70 tonnes

Shear force per m width = 31.11111 tonnes / m

Tv = Vu / bd = 0.333333 N/mm2

Pt 0 %

Ast 0 cm2/m

SHEAR NOT GUIDING


Shear considered at d/2 from face Y-Y:

Total number of piles contributing to shear = 0

Shear force = 0 tonnes

Shear force per m width = 0 tonnes / m

Tv = Vu / bd = 0 N/mm2

IF SHEAR REINFORCEMENT IS REQUIRED:

Percentage of steel Longitudinal provided: 0.2 %

Inherent Shear capacity for percentage of steel provided from SP16 or IS 456 (Tc): 0.34 N/mm2

If Tv >Tc, Force to be resisted by stirrups Vus : -476 KN/m

Vus/d : -3.4 kN/cm/m


NX NY DEPTH OF SELF
(m) (m) PILECAP(mWEIGHT (T)
0 0 0 0

NX NY DEPTH OF SELF
(m) (m) PILECAP(mWEIGHT (T)
0 0 0 0
kN/cm/m