Professional Documents
Culture Documents
Features
This product adopts an automatic operation method using sample water pressure which is matched to the
operation of an oil separator or pump.
The automatic washing function of the detection unit can reduce troublesome manual washing work.
An error code indication provided at occurrence of a device fault and a stain indication of the detection unit
facilitate maintenance and inspection. The product has a high-maintainability structure.
Operation records such as trouble alarms can be saved in a memory card and conrmed as required.
For alarms, a double safety method is used. When the oil concentration is 15 ppm or more,
and When sample water is defective or the instrument is defective, a alarm is output.
Replacement of detecting part (sensor) separately sold can be accepted. as the completion of every ve
Advanced device recognized
throughout the world.
This product conforms to
MEPC.10749
Product Specifications
-1-
Specifications
Maximum
measurement angle Within 22.5in each direction
of inclination
Water-proof grade IP = 54
Coating color 7.5BG 7/2 (Since this color is manufacturer standard, it cannot be changed.)
W=251 mm H=283.5 mm D=122 mm Total weightapprox. 4.8 kg
Outside dimension
excluding accessories
weight
body=approx. 3.0 kg. Sensor unit=approx. 0.6 kg. Solenoid valve unit = 1.2 kg
-2-
Outline dimensions Material etc
251
116 1.0 4-10 122
1
15ppm Bilge Alarm CAUTION
Sensor unit
8
If these attention are neglected,there is a fear
to cause damage,electric leakage,etc,of apparatus
FOCAS-2000
besides an obstacle in terms of functions may be
MODEL
260 1.2
found,so pay full attention.
283.5
If these attention are neglected,there is a fear
to cause damage,electric leakage,etc,of apparatus
besides an obstacle in terms of functions may be
found,so pay full attention.
9
Solenoid Body unit MODEL OF TYPE APPROVAL
2
DATE 20
TOKYO JAPAN
3
4 7
5 165 4.0
6
150 or more 116
85 or more
Maximum 265
4-10
4-M8
260
300 or more
100 or more
10
-3-
Internal Arrangement Drawing and the Terminal Base Arrangement
2 VALVE
Supply voltage output three-way valve
Alarm operating point of Valve and Alarm 1
is synchronized. Delay setting is available
C contact 250VAC, 2A max. Alarm signal 1 (external
4 Alarm 2
Dry contact
Alarm signal 2 (external signal)
5 REC 4-20mA 0-24mA current output When 20mA is loaded, the line resistance is 750or less
No Supply
between relay
VALVE COM-NC No output voltage No output
terminal output output
-4-
Spare parts model:FOCAS-2000 item
oil concentration detector FOCAS-2000 Hull No.
Spare Parts Table 2 Case No.
No Part name Part No. Sketch Material Work-ing backup mass remarks
Normal
Meltdown
1 Fuse for three-way Valve 2000-020 Glass tube 2 2 0.00075
type
2A
Fast-blow
Ceramic
2 Fuse for the equipment 2000-010 1 1 0.00075 type
tube
3.15A
0.01
5 Washing brush 2000-030 1
RC1/41
7 10 joint 2000-050 C3604 3 0.05 RC1/82
DATE TITLE
CHECK DESIGN DRAWIN MAR. 09. 2012 FOCAS-2000
APPOINT
kikuchi Okumura Okumura
Spare Parts Table
SCALE DRAWING NO
8960-01
-5-
Pipe connections
(recommend)
Drain outlet
Bilge Separator.
Bilge Alarm
Hopper
Height of Drainage
Sample water inlet
Restrictions on piping
5. The length from the sample water outlet to the end of piping should be within 2m and the fall should be within
1.5m. Be sure to provide hoppers.
6. Piping length between Bilge Separator and Bilge Alarm should be within 3m. Bilge Alarm should be set above the
Outlet height of Bilge Separator. Do not install Bilge Alarm lower than 2m below the top of Bilge Separator.
Operation pressure of Bilge Alarm is 0.03MPa 0.3MPa. In consideration of recommended pressure for Bilge
Separator, adjust the operation pressure.
Caution:
Be sure to follow the above instructions to run the oil concentration detector normally.
-6-