Features
Variable sensitivity
Electronically Addressed
Description
Model ACA-E is a Multi-Sensor, which is fully compatible with Hochikis ESP Analogue
Addressable Protocol, and incorporates a thermal element and High Performance photoelectric
smoke chamber.
The ACA-E has three modes, which are controlled from the Control Panel, allowing either the
optical element or thermal element or both elements to be active in making the fire decision.
The sensor polling LEDs can be controlled via the Control Panel (pulsing/non-pulsing). The
ACA-E smoke chamber can easily be removed or replaced for easy maintenance.
Specification
Sensor ACA-E
Ordering Codes
Replacement Chamber SLR-ALG REPLACEMENT CHAMBER
Operating Voltage 17 - 41Vd.c.
Low Power Mode (typ) 120A
Quiescent Current (typ) 450 A
Alarm Current (controlled by CIE) 19mA
Transmission Method Digital Communications Using ESP
Operating Temperature Range -10C to + 50C
Storage Temperature Range -30C to + 60C
Maximum Humidity 95%RH - Non Condensing (at 40C)
Ingress Protection Rating IP42
Colour / Case Material Ivory White / ABS
Weight (g) 100
Diameter (mm) / Height with base (mm) 100 / 46
Compatible Bases YBN-R/3, CHQ-BS, YBO-R/SCI
Base Fixing Centres (mm) 48 ~ 74
LPCB EN54: Parts 5 & 7, CEA 4021: 1999
Approvals
VdS EN54: Parts 5 & 7, CEA 4021: 1999 (G200120)
Hochiki Europe (UK) Ltd. reserves the right to alter the specification of its products from time to time without notice. Although every
effort has been made to ensure the accuracy of the information contained in this document it is not warranted or represented by
Hochiki Europe (UK) Ltd. to be a complete and up-to-date description.
Analogue Multi-Heat Sensor
ACB-E
Features
User selectable modes
Electronically Addressed
Description
Model ACB-E is a Multi-Heat Sensor, which is fully compatible with Hochikis ESP Analogue
Addressable Protocol.
The ACB-E incorporates a Variable Temperature heat element and a Rate Of Rise heat
element, both of which are controlled from the Control Panel, allowing either thermal element
or both elements simultaneously to be active in making the fire decision. The sensor polling
LEDs can also be controlled via the Control Panel (pulsing/non-pulsing).
Specification
Ordering Code ACB-E
Operating Voltage 17 - 41Vd.c.
Low Power Mode (typ) 110A
Quiescent Current (typ) 350A
Alarm Current (controlled by CIE) 19mA
Transmission Method Digital Communications Using ESP
Operating Temperature Range -10C to +50C
Storage Temperature Range -30C to +70C
Maximum Humidity 95%RH - Non Condensing (at 40C)
Ingress Protection Rating IP42
Colour / Case Material Ivory White / Polycarbonate
Weight (g) 100
Diameter (mm) / Height with base (mm) 100 / 46
Compatible Bases YBN-R/3, CHQ-BS, YBO-R/SCI
Base Fixing Centres (mm) 48 ~ 74
Hochiki Europe (UK) Ltd. reserves the right to alter the specification of its products from time to time without notice. Although every
effort has been made to ensure the accuracy of the information contained in this document it is not warranted or represented by
Hochiki Europe (UK) Ltd. to be a complete and up-to-date description.
Analogue Waterproof Multi-Heat Sensor
ACB-EW
Features
Electronically Addressed
IP Rated to IP67
Description
Model ACB-EW is a Waterproof Multi-Heat Sensor, which is fully compatible with Hochikis ESP
Analogue Addressable Protocol.
The ACB-EW incorporates a variable Fixed Temperature heat element and a Rate Of Rise heat
element, both of which are controlled from the Control Panel, allowing either thermal element
or both elements simultaneously to be active in making the fire decision. The sensor polling
LEDs can also be controlled via the Control Panel (pulsing/non-pulsing).
Rated to IP67, the ACB-EW can be used externally and is supplied with its own fixing base
which is used to fix the sensor. Flying leads from the sensor connect directly to the loop via
waterproof connectors.
Specification
Ordering Code ACB-EW
Operating Voltage 17 - 41Vd.c.
Low Power Mode (typ) 110A
Quiescent Current (typ) 350A
Alarm Current (controlled by CIE) 19mA
Transmission Method Digital Communications Using ESP
Operating Temperature Range -10C to +50C
Storage Temperature Range -30C to +70C
Maximum Humidity 95%RH - Non Condensing (at 40C)
Ingress Protection Rating IP67
Colour / Case Material Ivory White / Polycarbonate
Weight (g) 100
Diameter (mm) / Height with base (mm) 100 / 46
Compatible Bases Supplied base only
Base Fixing Centres (mm) 48 ~ 74
Hochiki Europe (UK) Ltd. reserves the right to alter the specification of its products from time to time without notice. Although every
effort has been made to ensure the accuracy of the information contained in this document it is not warranted or represented by
Hochiki Europe (UK) Ltd. to be a complete and up-to-date description.
Analogue Ionisation Sensor
AIE-E
Features
Variable sensitivity
Electronically Addressed
Description
Model AIE-E is an Ionisation Smoke Sensor, which is fully compatible with Hochikis ESP
Analogue Addressable Protocol.
A single radioactive source within the AIE-E ionises two chambers, which allows a small DC
current to flow between the electrodes in each chamber. Smoke can freely enter the outer
chamber whilst the inner chamber is virtually sealed. Smoke entering the outer chamber
causes a reduction in the DC current, the imbalance between the two currents is proportional
to smoke density, which is filtered and transmitted as the analogue value.
The threshold on the AIE-E can be adjusted to compensate for contamination by utilising the
built in test facility.
Specification
Ordering Code AIE-E / AIE-E(NP)
Operating Voltage 17 - 41Vd.c.
Low Power Mode (typ) 120A
Quiescent Current (typ) 310A
Alarm Current (controlled by CIE) 19mA
Transmission Method Digital Communications Using ESP
Radioactive Source Am241 1Ci
Operating Temperature Range -10C to + 50C
Storage Temperature Range -30C to + 60C
Maximum Humidity 95%RH - Non Condensing (at 40C)
Ingress Protection IP42
Colour / Case Material Ivory White / ABS
Weight (g) 115
Diameter (mm) / Height with base (mm) 100 / 46
Compatible Bases YBN-R/3, CHQ-BS, YBO-R/SCI
Base Fixing Centres (mm) 48 ~ 74
Approvals AIE-E LPCB EN54: Part 7
AIE-E(NP) VdS EN54: Part 7 (G299075)
Hochiki Europe (UK) Ltd. reserves the right to alter the specification of its products from time to time without notice. Although every
effort has been made to ensure the accuracy of the information contained in this document it is not warranted or represented by
Hochiki Europe (UK) Ltd. to be a complete and up-to-date description.
Analogue Photoelectric Smoke Sensor
ALG-E
Features
Removable, High Performance chamber
Variable sensitivity
Electronically addressed
Description
Model ALG-E is a Photoelectric Smoke Sensor, which is fully compatible with Hochikis ESP
Analogue Addressable Protocol. The ALG-E is also available in black, which makes it ideal for
nightclubs and cinemas where attention to aesthetics is required.
The ALG-E incorporates Hochikis unique High Performance Chamber Technology removing the
need to use Ionisation Sensors in the majority of applications. This also allows the sensor
threshold level to be increased, thereby improving the signal to noise ratio and reducing
susceptibility to false alarms.
The ALG-E smoke chamber is easily removed or replaced for cleaning and utilises a unique
baffle design which allows smoke to enter the chamber while keeping out ambient light.
Specification
Sensor ALG-E / ALG-E(NP) / ALG-E(BLACK)
Ordering Codes
Replacement Chamber SLR/ALG REPLACEMENT CHAMBER
Operating Voltage 17 - 41Vd.c.
Low Power Mode (typ) 122A
Quiescent Current (typ) 390A
Alarm Current (controlled by CIE) 19mA
Transmission Method Digital Communications Using ESP
Operating Temperature Range -10C to + 50C
Storage Temperature Range -30C to + 60C
Maximum Humidity 95%RH - Non Condensing (at 40C)
Ingress Protection Rating IP42
Colour / Case Material Ivory White / ABS
Weight (g) 98
Diameter (mm) / Height with base (mm) 100 / 46
Compatible Bases YBN-R/3, CHQ-BS, YBO-R/SCI
Base Fixing Centres (mm) 48 ~ 74
ALG-E LPCB EN54: Part 7
Approvals
ALG-E(NP) VdS EN54: Part 7 (G200118)
Hochiki Europe (UK) Ltd. reserves the right to alter the specification of its products from time to time without notice. Although every
effort has been made to ensure the accuracy of the information contained in this document it is not warranted or represented by
Hochiki Europe (UK) Ltd. to be a complete and up-to-date description.
Conventional Sounder
BANSHEE
Features
Robust design
Easy to install
32 user-selectable tones
Description
The BANSHEE is an electronic conventional sounder for both internal and external use. It is
easily installed with robust terminations that can accept 2.5mm cables and a push and twist
bayonet-fitting base. With the choice of two types of back box the BANSHEE can be used
externally as well as internally, with the weatherproof back box providing three 20mm cable
entries.
The BANSHEES various industry-standard tones and volume levels are all user-selected using
simple DIL switches on the underside of the unit.
Specification
Ordering Code BANSHEE
Operating Voltage 9 - 30Vdc
Operating Current 12 mA (20%)
Operating Temperature Range -40C to + 70C
Maximum Sound Output (at 24Vdc) 112dB(A) at 1 metre (dependant on tone
selected)
Maximum Humidity 75%RH - Non Condensing (at 40C)
IP Rating IP45 (with internal back box)
IP66 (with external back box)
Hochiki Europe (UK) Ltd. reserves the right to alter the specification of its products from time to time without notice. Although every
effort has been made to ensure the accuracy of the information contained in this document it is not warranted or represented by
Hochiki Europe (UK) Ltd. to be a complete and up-to-date description.
Conventional Alarm Bells
MBF-6EV and MBA-6
Specifications
Ordering Codes MBF-6EV MBA-6
Operating Voltage 20.4 27.6 Vdc
Rated Current (20%) 11mA 12mA
Operating Temperature Range -10C to + 50C
Maximum Humidity 45-85% Non Condensing (at 40C)
Gong Colour Red
Gong Material Aluminium
Maximum Sound Output dB(A) at 1 metre 96.5 100.5
Ingress Protection Rating IP23C IP33C
Weight (g) / Diameter (mm) / Depth (mm) 410 / 150 / 53 780 / 150 / 104
(inc back box) (inc back box)
Hochiki Europe (UK) Ltd. reserves the right to alter the specification of its products from time to time without notice. Although every effort has been
made to ensure the accuracy of the information contained in this document it is not warranted or represented by Hochiki Europe (UK) Ltd. to be a
complete and up-to-date description.
Manual Call Point with Short-Circuit Isolator
BGU-E(PS)
Features
Fast response
ESP compatible
IP54 Rated
Description
The BGU-E(PS) is an addressable splash-proof call-point with an integral short circuit isolator
which is fully ESP compatible. The BGU-E(PS) is addressed using the TCH-B100 Hand Held
Programmer with a programming lead and features two LED's, one RED and one YELLOW that,
between them, indicate the current state of the unit. For example, whether a fire has been
detected, or whether a short-circuit is present on the loop.
Specification
Ordering code BGU-E(PS)*1
Operating Voltage 17-31 Vdc
Sleep mode current 100 A (typ.)
Quiescent mode current 250 A (typ.)
Current - BGU-E(PS) operated (fire condition) 620 A (typ. without Fire LED on)
Current drawn by isolator during fault condition 8mA
Maximum continuous current 1A
Maximum quantity per loop 127*2
STATUS RED AMBER
Normal Off Off
SCI active Off On
Fire Condition On Off
Fire Condition and Short-Circuit Condition On Off
Protocol ESP
Operating temperature range -10 C to +50 C
Storage temperature range -30C to + 60C
Relative humidity 95% RH (at 40C)
Colour and case material Red ABS
Case dimensions (mm) 120H x 125W x 35D
Fixing centres 100 mm by 100mm
Maximum wire thickness 1.5 mm/terminal
Weight 240g
Ingress Protection Rating IP54 (splash-proof)
1
* Fire alarm control panel compatibility is required for this product.
2
* Check with Fire alarm control panel manufacturer for maximum loop quantities
Hochiki Europe (UK) Ltd. reserves the right to alter the specification of its products from time to time without notice. Although every
effort has been made to ensure the accuracy of the information contained in this document it is not warranted or represented by
Hochiki Europe (UK) Ltd. to be a complete and up-to-date description.
Conventional Manual Call Point
CCP-E
Features
Complies with BS5839 Part 2
Description
The CCP-E is a Conventional call-point based upon the industry standard KAC world series
housing and features easy to install, push-fit wiring terminals.
The unit can support either a Frangible Glass element or a Non Frangible Plastic element.
Specification
Ordering Code CCP-E
Nominal operating resistance 470
Maximum contact resistance (R) 200
Ingress Protection Rating IP24
Operating Temperature Range -10C to + 50C
Storage Temperature Range -30C to + 70C
Maximum Humidity 95%RH - Non condensing (at 40C)
Colour / Case Material Red / ABS
(Flush Mount) 110 / W89 x H93 x D27.5
Weight (g) / Dimensions (mm)
(Surface Mount with Back Box) 161 / W89 x H93 x D59.5
Frangible Element KAC/G/HE
Accessories
Non-Frangible Element KAC/EWS/HE
Hochiki Europe (UK) Ltd. reserves the right to alter the specification of its products from time to time without notice. Although every
effort has been made to ensure the accuracy of the information contained in this document it is not warranted or represented by
Hochiki Europe (UK) Ltd. to be a complete and up-to-date description.
Intrinsically Safe Conventional Call Point
CCP-E-IS
Features
Supports either a Frangible Glass
element or a Non Frangible Plastic
element
Rugged design
ATEX Classification to
II 1G Eex ia IIC T4
Description
The CCP-E-IS is a conventional call point based upon the industry standard KAC world series
housing, which can be used in hazardous areas.
Specification
Ordering Code CCP-E-IS
Operating Voltage 15 - 30V
Operating Temperature Range -10C to + 55C
Storage Temperature Range -30C to + 70C
ATEX Classification II 1 G Eex ia II T4
Maximum Humidity 95%RH - Non Condensing (at 40C)
Ingress Protection Rating IP24
Colour / Case Material Red / Polyphenylene Oxide
(Flush Unit) 93 / W88 x H88 x D20
Weight (g) / Dimensions (mm)
(With Surface Mount Back Box) 173 / W88 x H88 x D52
Hochiki Europe (UK) Ltd. reserves the right to alter the specification of its products from time to time without notice. Although every
effort has been made to ensure the accuracy of the information contained in this document it is not warranted or represented by
Hochiki Europe (UK) Ltd. to be a complete and up-to-date description.
Conventional Weatherproof
Manual Call Point
CCP-W
Features
Complies with BS5839 Part 2
IP rated to IP67
Description
The CCP-W is a Conventional call-point based upon the industry standard KAC world series
housing and features easy to install, push-fit wiring terminals.
The unit can support either a Frangible Glass element or a Non Frangible Plastic element and
features a weatherproof Housing to IP67, which means it can be mounted in the most severe
environmental conditions without water ingress.
Specification
Ordering Code CCP-W
Nominal operating resistance 470
Maximum contact resistance 200
Ingress Protection Rating IP67
Operating Temperature Range -10C to + 50C
Storage Temperature Range -30C to + 70C
Maximum Humidity 95%RH - Non condensing (at 40C)
Colour / Case Material Red / ABS
Weight (g) / Dimensions (mm) 234 / W98 x H94 x W78
Frangible Element KAC/G/HE
Accessories
Non-Frangible Element KAC/EWS/HE
Hochiki Europe (UK) Ltd. reserves the right to alter the specification of its products from time to time without notice. Although every
effort has been made to ensure the accuracy of the information contained in this document it is not warranted or represented by
Hochiki Europe (UK) Ltd. to be a complete and up-to-date description.
Analogue Addressable Loop-Powered
Beacons
CHQ-AB Range
Features
High Intensity LED technology
Approved by VdS
Description
The CHQ-AB range consists of addressable loop-powered Beacons, with high-intensity LEDs
and a Fresnel lens design which produces a highly visible flash.
The casings exactly match the Hochiki ESP Sensor range in shape and colour providing
seamless integration.
The units can be used on the Standard ESP Base (YBN-R/3), the Base Sounder (CHQ-BS) or
the Short-Circuit Isolator Base (YBO-R/SCI).
Specification
Ordering Code CHQ-AB(RED) / CHQ-AB(AMB) / CHQ-AB(BLU)
Operating Voltage 17 - 41Vd.c.
Quiescent Current (typ) 240A (300A max)
Loop current (when polled) 22mA 20%
Alarm Current (typ) 4.3mA (5.0mA max)
Operating Temperature Range -10C to + 50C
Storage Temperature Range -30C to + 60C
Maximum Humidity 95%RH - Non Condensing (at 40C)
Colour / Case Material Ivory White / ABS
Lens Colour CHQ-AB(RED) Transparent Red
CHQ-AB(AMB) Transparent Amber
CHQ-AB(BLU) Transparent Blue
Weight (g) / Diameter (mm) / Height (mm) 88 / 100 / 38 (46 with base)
Base Fixing Centres (mm) 48 ~ 74
Approvals VdS (G206052)
* Check control panel compatibility for this feature.
Hochiki Europe (UK) Ltd. reserves the right to alter the specification of its products from time to time without notice. Although every
effort has been made to ensure the accuracy of the information contained in this document it is not warranted or represented by
Hochiki Europe (UK) Ltd. to be a complete and up-to-date description.
Analogue Addressable Remote Indicator
CHQ-ARI (CLR)
Features
High Intensity LED technology
Approved by VdS
Description
The CHQ-ARI(CLR) is a loop-powered Addressable Remote Indicator, with high-intensity LEDs
and a Fresnel lens design which produces a highly visible signal.
The casing exactly matches the Hochiki ESP Sensor range in shape and colour providing
seamless integration.
The unit can be used on the Standard ESP Base (YBN-R/3), the Base Sounder (CHQ-BS) or the
Short-Circuit Isolator Base (YBO-R/SCI).
Specification
Ordering Code CHQ-ARI(CLR)
Operating Voltage 17 - 41Vd.c.
Quiescent Current (typ) 280A (300A max)
Loop current (when polled) 22mA 20%
Alarm Current (typ) 4.5mA (5.4mA max)
Operating Temperature Range -10C to + 50C
Storage Temperature Range -30C to + 60C
Maximum Humidity 95%RH - Non Condensing (at 40C)
Colour / Case Material Ivory White / ABS
Lens Colour Transparent (Clear)
Weight (g) / Diameter (mm) / Height (mm) 88 / 100 / 38 (46 with base)
Base Fixing Centres (mm) 48 ~ 74
Approvals VdS (G206053)
Hochiki Europe (UK) Ltd. reserves the right to alter the specification of its products from time to time without notice. Although every
effort has been made to ensure the accuracy of the information contained in this document it is not warranted or represented by
Hochiki Europe (UK) Ltd. to be a complete and up-to-date description.
Analogue Dual Circuit Sounder Controller
CHQ-B
Features
Single Loop Address
Description
Model CHQ-B is a Dual Sounder Controller, which has been designed to provide two sounder
outputs (that can be driven separately) with full fault monitoring. The monitored input can be
used for local power supply fault monitoring or as a general-purpose input.
The CHQ-B utilises simple DIL switches for reliable addressing and it is available in either an
OEM version (as illustrated above) or complete with an IP67 rated enclosure.
Specification
Ordering Code CHQ-B/OEM (without box as shown)
Operating Voltage 17 - 41Vd.c.
Low Power Mode (typ) 106A
Quiescent Current (typ) 290A (add: 200a per Active Sounder Line)
Current Consumption Sounder On: 8mA (per line)
(External Supply) Sounder Fault: 6mA (per line)
External Supply Voltage 19.2 - 30 Vd.c.
Sounder Output Current 1A/Line Max
Sounder Line Capacitance 0.30F Max/Line
Sounder EOL Device 1k, + 5%, 2W
Input Threshold Levels ON =470, short cct = <50, open cct>100K,
EOL = 10K
Operating Temperature Range -10C to +50C
Storage Temperature Range -30C to +60C
Maximum Humidity 95%RH Non Condensing (at 40C)
(OEM) 88 / L187 x W98 x H31
(OEM with box) 120 / L235 x W160 x H92
Weight (g) / Dimensions (mm)
(DIN Rail Version) 145 / L119 x H108 x D24
(DIN Rail Version with SCI) 147 / L119 x H108 x D24
Hochiki Europe (UK) Ltd. reserves the right to alter the specification of its products from time to time without notice. Although every
effort has been made to ensure the accuracy of the information contained in this document it is not warranted or represented by
Hochiki Europe (UK) Ltd. to be a complete and up-to-date description.
Analogue Mini Zone Controller
CHQ-MZ
Features
Loop Powered
Up to 6 Conventional Detectors
Description
Model CHQ-MZ is a Mini Zone Controller designed to allow up to 6 conventional detectors to be
interfaced to Hochikis ESP analogue addressable system. Also available as a DIN Rail
mountable version, with or without an integral short-circuit isolator (CHQ-MZ/DIN(SCI) or CHQ-
MZ/DIN). The CHQ-MZ utilises simple DIL switches for reliable addressing. It is available as an
OEM version (as illustrated above) which can be fitted within an IP67 rated enclosure.
The conventional zone on the CHQ-MZ does not support any line continuity
options, therefore if Call Points are being interfaced they should be wired at
the beginning of the zone.
Specification
Ordering Codes CHQ-MZ/OEM (without box as shown)
CHQ-MZ/DIN (DIN Rail version)
CHQ-MZ/DIN(SCI) (DIN Rain with short-circuit isolator)
Operating Voltage 17 - 41Vd.c.
Low Power Mode (typ) 120A*
Quiescent Current (typ) 260A*
Alarm (typ) 63mA (remote LED on)
Capacitance on Zone 0.3F Max
Resistance on Zone 50 Max
Operating Temperature Range -10C to +50C
Storage Temperature Range -30C to +60C
E.O.L. Device TE-RH-E
DFE - no limit
Quantity per Zone SLR, DCD, SLR-E3 - 6 max, HF24 one only - no other detector
Conventional Call Points - no limit
Colour / Case Material Ivory White / ABS
(OEM) 77 / L148 x W92 x H23
(OEM with optional enclosure) 386 / L160 x W110 x H92
Weight (g) / Dimensions (mm)
(DIN Rail version) 109 / L119 x D24 x H108
(DIN Rail version with SCI) 112 / L119 x D24 x H108
Approval (CHQ-MZ/OEM) LPCB
*Note: SCI version will take additional current (50A).
Hochiki Europe (UK) Ltd. reserves the right to alter the specification of its products from time to time without notice. Although every
effort has been made to ensure the accuracy of the information contained in this document it is not warranted or represented by
Hochiki Europe (UK) Ltd. to be a complete and up-to-date description.
Analogue Dual Relay Controller
CHQ-R
Features
Loop Powered
Single Address
Description
Model CHQ-R/OEM is a Dual Relay Controller designed to provide two general-purpose relay
out puts, each output can be driven separately for control of such devices as dampers or for
control of plant and equipment shutdown. The monitored input can be used for local power
supply fault monitoring or as a general-purpose input. Also available as a DIN Rail mountable
version with or without an integral short-circuit isolator (CHQ-R/DIN(SCI) or CHQ-R/DIN).
Specification
CHQ-R/OEM (without box as shown)
Ordering Codes CHQ-R/DIN (DIN Rail version)
CHQ-R/DIN(SCI) (DIN Rail version with short-circuit isolator)
Operating Voltage 17 - 41Vd.c.
Low Power Mode (typ) 120A*
Quiescent Current (typ) 300A*
Relay Contact Rating 30Vd.c. max, 1A (resistive load)
Input EOL Resistor 10k, + 5% 0.25W
Input threshold Levels ON =470, short cct<50, open cct>100k, EOL=10K
Operating Temperature Range -10C to +50C
Storage Temperature Range -30C to +60C
Maximum Humidity 95% RH Non Condensing (at 40C)
Colour / Case Material Ivory White / ABS
(OEM) 85 / L148 x H89 x D23
(OEM with box) 120 / L160 x W110 x H92
Weight (g) / Dimensions (mm)
(DIN) 120 / L119 x W24 x H108
(DIN(SCI)) 121 / L119 x W24 x H108
Hochiki Europe (UK) Ltd. reserves the right to alter the specification of its products from time to time without notice. Although every
effort has been made to ensure the accuracy of the information contained in this document it is not warranted or represented by
Hochiki Europe (UK) Ltd. to be a complete and up-to-date description.
Analogue Dual Switch Monitor
CHQ-S
Features
Single Loop Address
Loop Powered
Description
Model CHQ-S/OEM is a Dual Switch Monitor designed to interface to a variety of inputs such as
door contacts, sprinkler flow/door switches and plant equipment. Also available as a DIN Rail
mountable version, with or without an integral short-circuit isolator (CHQ-S/DIN(SCI) or
CHQ-S/DIN).
Specification
CHQ-S/OEM (without box as shown)
Ordering Codes CHQ-S/DIN (DIN Rail Version)
CHQ-S/DIN(SCI) (DIN Rail version with short-circuit isolator)
Operating Voltage 17 - 41Vd.c.
Low Power Mode (typ) 97A*
Quiescent Current (typ) 280A*
Active Current (typ) 4.3mA (both inputs active) - add 85A per input for normally
closed contact monitoring
Input Line Resistance ON threshold <50, OFF threshold >100k
Operating Temperature Range -10C to + 50C
Storage Temperature Range -30C to + 60C
Maximum Humidity 95%RH - Non Condensing (at 40C)
Colour / Case Material Ivory White / ABS
Weight (g) / Dimensions (mm) (OEM) 75 / L148 x W89 x H23
(OEM with box) 384 / L160 x W110 x H92
(DIN Rail Version) 107 / L119 x H108 x D24
(DIN Rail Version with SCI) 112 / L119 x H108 x D24
Approval (CHQ-S/OEM) LPCB
Hochiki Europe (UK) Ltd. reserves the right to alter the specification of its products from time to time without notice. Although every
effort has been made to ensure the accuracy of the information contained in this document it is not warranted or represented by
Hochiki Europe (UK) Ltd. to be a complete and up-to-date description.
Single Input/Output Module
CHQ-SIO
Features
Loop Powered
Single Address
Approved by LPCB
Description
Model CHQ-SIO is a Single Input / Output Module, which provides a single mains rated relay
output (via the flying leads) for the control of such devices as dampers, extractors or plant and
equipment shutdown.
The monitored can be used for local power supply fault monitoring or as a general-purpose
input. The CHQ-SIO utilises simple DIL switches for reliable addressing and it is supplied as an
OEM version (as illustrated above).
Specification
Ordering Code CHQ-SIO/OEM (without box as shown)
Operating Voltage 17 - 41Vd.c.
Low Power Mode (typ) 120A (typ)
Quiescent Current (typ) 300A (typ)
48 Vd.c. max, 2A (resistive load)
Relay Contact Rating
250Va.c. max, 5A (resistive load)
Input EOL Resistor 10k, + 5% 0.25 W
Input threshold Levels ON = 470, short cct <50, open cct>100k, EOL=10K
Operating Temperature Range -10C to +50C
Storage Temperature Range -30C to +60C
Maximum Humidity 95% RH Non Condensing (at 40C)
(OEM) 85 / L148 x W89 x H23
Weight (g) / Dimensions (mm)
(OEM with box) 120 / L160 x W110 x H92
Approval LPCB
Hochiki Europe (UK) Ltd. reserves the right to alter the specification of its products from time to time without notice. Although every
effort has been made to ensure the accuracy of the information contained in this document it is not warranted or represented by
Hochiki Europe (UK) Ltd. to be a complete and up-to-date description.
Analogue Wall Sounder
CHQ-WS2
Features
Loop Powered
51 User-Selectable Tones
Description
Model CHQ-WS2 is an addressable loop powered Wall Sounder innovatively designed to provide
a range of tones and volumes with a maximum output of up to 102dB(A)
(2dB(A)) with low current consumption. The unit is designed to fit to the Standard Base
(YBO-R/3(RED)) or the Isolator Base (YBO-R/SCI(RED)). The sounder is IP rated to IP21 for
internal use but it can be made weatherproof by utilising the WS2-WPK Weatherproof Kit, which
consists of a specialised back box and gasket set.
Also incorporates an auto shutdown mode* which allows the user to set a fixed time within
which the sounder will operate, before automatically silencing itself, ideal for minimising noise
pollution.
Specification
Ordering Codes CHQ-WS2 / CHQ-WS2(WHITE) / WS2-WPK (Weatherproof Kit)
Operating Voltage 17 ~ 41Vd.c.
150A (with YBO-R/3(RED))
Quiescent Current (typ)
200A (with YBO-R/SCI(RED))
Sounding Current (typ) 2mA (90dB(A) (2dB(A)) @ 1m) ~
8mA (102dB(A) (2dB(A)) @ 1m)
Sound Output (at 1 metre) 90 ~ 102dB(A) (2dB(A)) @ 24Vd.c. or above
Number of Tones 51
Tone Frequency Range 300Hz ~ 2850Hz
Operating Temperature Range -10C to +50C
Storage Temperature Range -30C to +70C
Maximum Humidity 95%RH - Non Condensing (at 40C)
Colour/Case Material Red or White/ PC ABS
Ingress Protection Rating IP21 (IP65 with WS2-WPK)
Weight (g)/Dimensions (mm) 152 / H112 x W112 x D67
Base Fixing Centres (mm) 48 ~ 74
*Dependent on control panel compatibility.
Description
Model CHQ-Z is a Dual Circuit Zone Controller designed to allow up to 60 conventional
detectors (30 on each zone) to be interfaced to Hochikis ESP analogue addressable system.
Full monitoring against malfunction or disconnection, together with a self-test feature through
the ESP protocol, ensure the integrity of the CHQ-Z at all times. The CHQ-Z utilises simple DIL
switches for reliable addressing. It is available as an OEM version (as illustrated above) with
an optional IP67 rated enclosure also available.
The conventional zone on the CHQ-Z does not support any line continuity
options, therefore if Call Points are being interfaced they should be wired at
the beginning of the zone.
Specification
Ordering Code CHQ-Z/OEM (without box as shown)
Operating Voltage 17 - 41Vd.c.
Low Power Mode (typ) 110A
Quiescent Current (typ) 300A
(Quiescent) 800A
Current Consumption (External )
(Alarm) 70mA (both zones in fire)
Capacitance on Zone 0.3F Max
Resistance on Zone 50 Max
Operating Temperature Range -10C to +50C
Storage Temperature Range -30C to +60C
E.O.L Device TE-RH-E
Open Collector Output Rating 30Vdc 30mA
DFE - no limit
Quantity per Zone
SLR, SIJ, DCD 30 max
(OEM) 118 / L187 x H92 x D30
Weight (g) / Dimensions (mm)
(OEM with box) 673 / L235 x W160 x H92
Approval LPCB
Hochiki Europe (UK) Ltd. reserves the right to alter the specification of its products from time to time without notice. Although every
effort has been made to ensure the accuracy of the information contained in this document it is not warranted or represented by
Hochiki Europe (UK) Ltd. to be a complete and up-to-date description.
I.S. Compatible Dual Zone Monitor
CHQ-Z(I.S.)
Features
Single loop address
Description
Model CHQ-Z(I.S.) is a Dual Circuit Controller which is fully compatible with Hochikis ESP
analogue addressable protocol and I.S. equipment. The unit will allow connection of up to forty
Hochiki I.S. conventional detectors through a Galvanic isolator, which are fully monitored for
open and short circuit. An open collector output is provided but will only operate if supported
by the Control Panel. (Please note that this module should only be installed in the safe
area.)
The conventional zones on the CHQ-Z(I.S.) do not support any line continuity options;
therefore if Call Points are being interfaced they should be wired at the beginning of the zone.
Specification
Ordering Code CHQ-Z(I.S.)/OEM (without box as shown)
Operating Voltage 17 - 41Vd.c.
Low Power Mode (typ) 110A
Quiescent Current (typ) 300A
Current Consumption (Quiescent) 11mA min (plus detector load)
(External 24V ) (Alarm) 100mA (both zones in fire)
Capacitance Per Conventional Zone 0.3F Max
Resistance Per Conventional Zone 50 Max
Operating Temperature Range -10C to +50C
Storage Temperature Range -30C to +60C
E.O.L Devices 10K resistors (supplied with module)
MTL 3043, 4061, 5061, KFDO-CS-Ex1.51, KFDO-CS-
Supported Barriers
Ex2.51, KFDO-CS-Ex1.51P, KFDO-CS-Ex2.51P
Open Collector Output Rating 30Vdc, 30mA
Detectors per Zone SLR-E-I.S (or DCD-1E-IS) & Call Points : 20MAX
Colour / Case Material Ivory White / ABS
(OEM) 127 / L185 x H97 x D30
Weight (g) / Dimensions (mm)
(OEM with optional box) 682 / L235 x W160 x H92
Hochiki Europe (UK) Ltd. reserves the right to alter the specification of its products from time to time without notice. Although every
effort has been made to ensure the accuracy of the information contained in this document it is not warranted or represented by
Hochiki Europe (UK) Ltd. to be a complete and up-to-date description.
Conventional Beacon
CLB-E
Features
High Intensity LED technology
Description
Model CLB-E(RED) is a conventional Beacon for use on 24V Sounder Circuits.
The unit is fitted with a Fresnel lens and high-intensity LEDs, a design which produces a highly
visible flash. The casing exactly matches the CDX Detector range in shape and colour
providing seamless integration.
Specification
Operating Voltage 17 - 41Vd.c.
Operating Current (typ) 4.3mA (5.0mA max)
Operating Temperature Range -10C to +50C
Storage Temperature Range -30C to +60C
Maximum Humidity 95% RH - Non Condensing (at 40C)
Colour / Case Material Ivory White / ABS
Lens Colour Transparent Red
Weight (g) 88
Base Fixing Centres (mm) 48 ~ 74
Hochiki Europe (UK) Ltd. reserves the right to alter the specification of its products from time to time without notice. Although every
effort has been made to ensure the accuracy of the information contained in this document it is not warranted or represented by
Hochiki Europe (UK) Ltd. to be a complete and up-to-date description.
Intrinsically Safe Conventional Rate of Rise
Heat Detector
DCD-1E-IS
Features
Twin fire LED's allow 360 viewing
ATEX Classification to
II 1G EEx ia IIC T5 Tamb=55C
Description
The DCD-1E-IS is an Intrinsically Safe Conventional Rate of Rise Heat Detector with a 60 fixed
temperature element.
Specification
Ordering Code DCD-1E-IS
Operating Voltage 15 - 30Vd.c.
Quiescent Current (typ) 50A
Maximum Current in Alarm 50mA
Operating Temperature Range -10C to + 55C
Storage Temperature Range -30C to + 70C
Maximum Humidity 95%RH - Non Condensing (at 40C)
Ingress Protection Rating IP63
Colour / Case Material Ivory White / ABS
Weight (g) / Diameter (mm) / Height (mm) 97 / 100 / 40
Compatible Base / Height (mm) YBN-R/4(IS) / 8
Fixing Centres (mm) 48 ~ 74
Approvals ATEX BAS01ATEX1021
LPCB
Germanischer Lloyd
Hochiki Europe (UK) Ltd. reserves the right to alter the specification of its products from time to time without notice. Although every
effort has been made to ensure the accuracy of the information contained in this document it is not warranted or represented by
Hochiki Europe (UK) Ltd. to be a complete and up-to-date description.
Conventional Combined Rate of Rise & Fixed
Temperature Heat Detector (60C)
DCD-AE3
Features
Electronic linear heat detection
Description
Model DCD-AE3 is a Rate of Rise Heat Detector with a 60C fixed temperature element using a
thermistor and linearising circuit to provide an accurate linear response Heat Detector.
The DCD-AE3 is ideal for use where medium ambient temperatures exist, such as drying
rooms or where Smoke Detectors are unsuitable because of the presence of steam or cooking
fumes such as in a kitchen.
The DCD-AE3 is supported by a range of bases for different applications and these are
supported on the majority of conventional systems. A third terminal provides remote indicator
output.
Specification
Ordering Code DCD-AE3
Operating Voltage 9.5 - 30Vd.c.
Quiescent Current (typ) 35A
Maximum Current in Alarm (typ) 40mA
Remote Indicator Drive 20mA (max) / 9.5-14mA (typ)
Operating Temperature Range -10C to +50C
Storage Temperature Range -30C to +70C
Maximum Humidity 95%RH - Non Condensing (at 40C)
Ingress Protection Rating IP63
Colour / Case Material Ivory White / Polycarbonate
Weight (g) / Diameter (mm) / Height (mm) 76 / 100 / 38
YBN-R6, YBN-R/6SK, YBO-R/6R,
Compatible Bases
YBO-R/6RS, YBO-R/6RN, YBO-R/6PA
Base Fixing Centres (mm) 48 ~ 74
LPCB
Approvals to (EN54:2000) Class A1 & A1R
VdS (G204044)
Hochiki Europe (UK) Ltd. reserves the right to alter the specification of its products from time to time without notice. Although every
effort has been made to ensure the accuracy of the information contained in this document it is not warranted or represented by
Hochiki Europe (UK) Ltd. to be a complete and up-to-date description.
Marine Approved Conventional Combined
Rate of Rise & Fixed Temperature Heat
Detector (60C)
DCD-AE3M
Features
Electronic linear heat detection
Description
Model DCD-AE3M is a Marine Approved Rate of Rise Heat Detector with a 60C fixed
temperature element using a thermistor and linearising circuit to provide an accurate linear
response Heat Detector.
The DCD-AE3M is ideal for use where medium ambient temperatures exist, such as drying
rooms or where Smoke Detectors are unsuitable because of the presence of steam or cooking
fumes such as in a kitchen/galley.
Specification
Ordering Code DCD-AE3M
Operating Voltage 9.5 - 30Vd.c.
Quiescent Current (typ) 35A
Maximum Current in Alarm (typ) 40mA
Remote Indicator Drive 20mA (max) / 9.5-14mA (typ)
Operating Temperature Range -10C to +50C
Storage Temperature Range -30C to +70C
Maximum Humidity 95%RH - Non Condensing (at 40C)
Ingress Protection Rating IP63
Colour / Case Material Ivory White / Polycarbonate
Weight (g) / Diameter (mm) / Height (mm) 76 / 100 / 38
Compatible Base YBN-R/6M
Base Fixing Centres (mm) 48 ~ 74
LPCB, Lloyds Register, Germanischer
Approvals to (EN54:2000) Class A1 & A1R
Lloyd, MCA
Hochiki Europe (UK) Ltd. reserves the right to alter the specification of its products from time to time without notice. Although every
effort has been made to ensure the accuracy of the information contained in this document it is not warranted or represented by
Hochiki Europe (UK) Ltd. to be a complete and up-to-date description.
Conventional Combined Rate of Rise & Fixed
Temperature Heat Detector (90C)
DCD-CE3
Features
Electronic linear heat detection
Description
Model DCD-CE3 is a Rate of Rise Heat Detector with a 90C fixed temperature element using a
thermistor and linearising circuit to provide an accurate linear response Heat Detector.
The DCD-CE3 is ideal for use where medium ambient temperatures exist, such as drying
rooms or where Smoke Detectors are unsuitable because of the presence of steam or cooking
fumes such as in a kitchen.
The DCD-CE3 is supported by a wide range of bases for different applications and these are
supported on the majority of conventional systems. A third terminal provides remote indicator
output.
Specification
Ordering Code DCD-CE3
Operating Voltage 9.5 - 30Vd.c.
Quiescent Current (typ) 35A
Maximum Current in Alarm 40mA
Remote Indicator Drive 20mA (max) / 9.5-14mA (typ)
Operating Temperature Range -10C to +50C
Storage Temperature Range -30C to +70C
Maximum Humidity 95%RH - Non Condensing (at 40C)
Ingress Protection Rating IP63
Colour / Case Material Ivory White / Polycarbonate
Weight (g) / Diameter (mm) / Height (mm) 76 / 100 / 38
YBN-R6, YBN-R/6SK, YBO-R/6R,
Compatible Bases
YBO-R/6RS, YBO-R/6RN, YBO-R/6PA
Base Fixing Centres (mm) 48 ~ 74
LPCB
Approvals to (EN54:2000) Class C & CR
VdS (G204045)
Hochiki Europe (UK) Ltd. reserves the right to alter the specification of its products from time to time without notice. Although every
effort has been made to ensure the accuracy of the information contained in this document it is not warranted or represented by
Hochiki Europe (UK) Ltd. to be a complete and up-to-date description.
Conventional Combined Rate of Rise & Fixed
Temperature Heat Detector (90C)
DCD-CE3M
Features
Electronic linear heat detection
Description
Model DCD-CE3M is a Marine Approved Rate of Rise Heat Detector with a 90C fixed
temperature element using a thermistor and linearising circuit to provide an accurate linear
response Heat Detector.
The DCD-CE3M is ideal for use where medium ambient temperatures exist, such as drying
rooms or where Smoke Detectors are unsuitable because of the presence of steam or cooking
fumes such as in a kitchen/galley.
Specification
Ordering Code DCD-CE3M
Operating Voltage 9.5 - 30Vd.c.
Quiescent Current (typ) 35A
Maximum Current in Alarm 40mA
Remote Indicator Drive 20mA (max) / 9.5-14mA (typ)
Operating Temperature Range -10C to +50C
Storage Temperature Range -30C to +70C
Maximum Humidity 95%RH - Non Condensing (at 40C)
Ingress Protection Rating IP63
Colour / Case Material Ivory White / Polycarbonate
Weight (g) / Diameter (mm) / Height (mm) 76 / 100 / 38
Compatible Base YBN-R/6M
Base Fixing Centres (mm) 48 ~ 74
LPCB, Lloyds Register, Germanischer
Approvals to (EN54:2000) Class C & CR
Lloyd, MCA
Hochiki Europe (UK) Ltd. reserves the right to alter the specification of its products from time to time without notice. Although every
effort has been made to ensure the accuracy of the information contained in this document it is not warranted or represented by
Hochiki Europe (UK) Ltd. to be a complete and up-to-date description.
Conventional Waterproof Heat Detector
DFG-60E (60C)
Features
Waterproof design rated to IP67
Description
Model DFG-60E is a 60C Fixed Temperature Waterproof Heat Detector, the detector uses a
bi-metallic strip to sense temperature change, therefore consuming minimal standby current
and providing high reliability.
The DFG-60E is particularly suited to environments, which are exposed to high levels of
condensation or are hosed down. The detector has a wide operating margin allowing it to
respond to both slow and fast increases in temperature; it can also sense temperature
reliably in a horizontal or vertical position.
The DFG-60E requires no mounting base as short flying leads are provided for connection to
the conventional zone and remote LED. If a back box is required, then the DFG-60E can be
mounted using the Hochiki MBB-1 Marine Approved back Box.
Specification
Ordering Code DFG-60E (DFG-BLKJ)
Operating Voltage 15 - 30Vd.c. (Nominal rating 24Vd.c.)
Quiescent Current (typ) Minimal
Maximum Current in Alarm 50mA at 24Vd.c.
Operating Temperature Range -10C to +60C
Storage Temperature Range -30C to +70C
Ingress Protection Rating IP67
Colour / Case Material Ivory / Modified Polycarbonate
Weight (g) / Diameter (mm) / Height (mm) 80 / 98 / 45
Fixing Centres (mm) 70
LPCB
Approvals to EN54: 2000 Part 5
VdS (G204048)
Hochiki Europe (UK) Ltd. reserves the right to alter the specification of its products from time to time without notice. Although every
effort has been made to ensure the accuracy of the information contained in this document it is not warranted or represented by
Hochiki Europe (UK) Ltd. to be a complete and up-to-date description.
Conventional Fixed Temperature Heat
Detector (60C)
DFJ-AE3
Features
Electronic linear heat detection
Description
Model DFJ-AE3 is a 60C Fixed Temperature Heat Detector using a thermistor and linearising
circuit to provide an accurate linear response Heat Detector. A third terminal provides integral
remote indicator output.
The DFJ-AE3 is ideal for use where medium ambient temperatures exist, such as drying rooms
or where Smoke Detectors are unsuitable because of the presence of steam or cooking fumes
such as in a kitchen.
Specification
Ordering Code DFJ-AE3
Operating Voltage 9.5 - 30Vd.c.
Quiescent Current (typ) 35A
Maximum Current in Alarm 40mA
Remote Indicator Drive 20mA (max) / 9.5-14mA (typ)
Operating Temperature Range -10C to +50C
Storage Temperature Range -30C to +70C
Maximum Humidity 95%RH - Non Condensing (at 40C)
Ingress Protection Rating IP63
Colour / Case Material Ivory White / Polycarbonate
Weight (g) / Diameter (mm) / Height (mm) 76 / 100 / 38
YBN-R6, YBN-R/6SK, YBO-R/6R,
Compatible Bases
YBO-R/6RS, YBO-R/6RN, YBO-R/6PA
Base Fixing Centres 48 ~ 74
LPCB
Approvals to (EN54:2000) Class A1 & A1S
VdS (G204046)
Hochiki Europe (UK) Ltd. reserves the right to alter the specification of its products from time to time without notice. Although every
effort has been made to ensure the accuracy of the information contained in this document it is not warranted or represented by
Hochiki Europe (UK) Ltd. to be a complete and up-to-date description.
Conventional Fixed Temperature Heat
Detector (90C)
DFJ-CE3
Features
Electronic linear heat detection
Description
Model DFJ-CE3 is a 90C Fixed Temperature Heat Detector using a thermistor and linearising
circuit to provide an accurate linear response Heat Detector. A third terminal provides integral
remote indicator output.
The DFJ-CE3 is ideal for use where medium ambient temperatures exist, such as drying rooms
or where Smoke Detectors are unsuitable because of the presence of steam or cooking fumes
such as in a kitchen.
The DFJ-CE3 is supported by a wide range of bases for different applications and these are
supported on the majority of conventional systems.
Specification
Ordering Code DFJ-CE3
Operating Voltage 9.5 - 30Vdc
Quiescent Current (typ) 35A
Maximum Current in Alarm 40mA
Operating Temperature Range -10C to +50C
Storage Temperature Range -30C to +70C
Maximum Humidity 95%RH - Non Condensing (at 40C)
Ingress Protection Rating IP63
Colour / Case Material Ivory White / Polycarbonate
Weight (g) / Diameter (mm) / Height with base (mm) 76 / 100 / 47
YBN-R6, YBN-R/6SK, YBO-R/6R,
Compatible Bases
YBO-R/6RS, YBO-R/6RN, YBO-R/6PA
Base Fixing Centres (mm) 48 ~ 74
LPCB
Approvals to (EN54:2000) Class C & CS
VdS (G204047)
Hochiki Europe (UK) Ltd. reserves the right to alter the specification of its products from time to time without notice. Although every
effort has been made to ensure the accuracy of the information contained in this document it is not warranted or represented by
Hochiki Europe (UK) Ltd. to be a complete and up-to-date description.
Electromagnetic Door Retainer
DR-24
Features
24Vd.c.
Surface mounted
Description
Model DR-24 is an electromagnetic door retainer which ensures retention of the door by means
of a smart metallic keeper plate.
It is designed to hold open fire doors and is ideally suited for hospitals, schools and other
public buildings.
In a fire situation the doors can be released automatically via a connection to the fire alarm
system or manually by activating the release button.
Specification
Ordering Code DR-24
Operating Voltage Range 20.4 -27.6Vd.c.
Nominal Current 30mA
Nominal Power (at 20C) 0.6W
Holding Force 200N
Operating Temperature Range 0C to +40C
(Back Box) 42 / H83 x W83 x D52
Weight (g) / Dimensions (mm)
(Swivel Keeper Plate) 12 / H55 x W55 x D52
IP Rating IP54
Hochiki Europe (UK) Ltd. reserves the right to alter the specification of its products from time to time without notice. Although every
effort has been made to ensure the accuracy of the information contained in this document it is not warranted or represented by
Hochiki Europe (UK) Ltd. to be a complete and up-to-date description.
Analogue Addressable Manual Call Point
HCP-E
Features
Fast response
Status LED
Description
Model HCP-E is a Manual Call Point, which is fully compatible with Hochikis ESP analogue
addressable protocol.
The HCP-E incorporates a red LED mounted on the front cover, which can be selected as
pulsing/non-pulsing*1 for communications polling and is continuously lit when the HCP-E is
operated. The unit is operated by pressing the EN54 compliant non-frangible (plastic) element
and, once operated, produces a high level ESP interrupt, allowing the control panel to respond
very quickly. A built in test function initiated by the control panel ensures the integrity of the
device at all times and the device can be tested by insertion of a test key in the underside of
the unit. Two terminal blocks are provided for easy connection to the loop wiring.
The unit is addressed using the TCH-B100 Hand Held Programmer for quick and reliable
addressing and the unit can also be flush mounted if required. An optional glass element is
also available.
Specification
Ordering Code HCP-E
Back Box Ordering Code SR
Operating Voltage 17 - 41Vd.c.
Low Power Mode (typ) 90A
Quiescent Current (typ) 220A
Alarm Current (typ) 5.0mA
Transmission Method Digital Communication Using ESP
Operating Temperature Range -10C to + 50C
Storage Temperature Range -30C to + 60C
Maximum Humidity 95%RH - Non Condensing (at 40C)
Ingress Protection Rating IP24
Colour / Case Material Red / Modified Polyphenylene Oxide
(Flush Unit) 110 / W89 x H93 x D27.5
Weight (g) / Dimensions (mm)
(With Surface Mount Back Box) 161 / W89 x H93 x D59.5
Approval LPCB EN 54-11:2001
*1
Fire alarm control panel compatibility is required for this feature.
Hochiki Europe (UK) Ltd. reserves the right to alter the specification of its products from time to time without notice. Although every
effort has been made to ensure the accuracy of the information contained in this document it is not warranted or represented by
Hochiki Europe (UK) Ltd. to be a complete and up-to-date description.
Analogue Addressable Manual Call Point
HCP-E(DPS)
Features
Fast response
Status LED
Description
Model HCP-E(DPS) is a Manual Call Point, which is fully compatible with Hochikis ESP analogue
addressable protocol.
The HCP-E(DPS) incorporates a red LED mounted on the front cover, which can be selected as
pulsing/non-pulsing*1 for communications polling and is continuously lit when the HCP-E(DPS)
is operated. The unit is operated by pressing the EN54 compliant non-frangible (plastic)
element and, once operated, produces a high level ESP interrupt, allowing the control panel to
respond very quickly. A built in test function initiated by the control panel ensures the integrity
of the device at all times and the device can be tested by insertion of a test key in the
underside of the unit. Two terminal blocks are provided for easy connection to the loop wiring.
The unit is addressed using the TCH-B100 Hand Held Programmer for quick and reliable
addressing and the unit can also be flush mounted if required. An optional glass element is
also available. The HCP-E(DPS) also incorporates a change over C Form contact that allows
the installer to connect additional equipment to the Call Point. The C Form contact is non-
latching, and will change state when the test key is inserted, and will return to the original
position when the test key is removed.
Specification
Ordering Code HCP-E(DPS)
Back Box Ordering Code SR1T
Operating Voltage 17 - 41Vd.c.
Low Power Mode (typ) 90A (typ)
Quiescent Current (typ) 220A (typ)
Alarm Current (typ) 5.0mA
Contact Rating 24Vd.c. @ 1A (non-inductive)
Transmission Method Digital Communication Using ESP
Operating Temperature Range -10C to + 50C
Storage Temperature Range -30C to + 60C
Maximum Humidity 95%RH - Non Condensing (at 40C)
Ingress Protection Rating IP24
Colour / Case Material Red / Modified Polyphenylene Oxide
(Flush Unit) 100 / L88 x H88 x W20
Weight (g) / Dimensions (mm)
(Surface Box) 80 / L88 x H88 x W32
*1
Fire alarm control panel compatibility is required for this feature.
Hochiki Europe (UK) Ltd. reserves the right to alter the specification of its products from time to time without notice. Although every
effort has been made to ensure the accuracy of the information contained in this document it is not warranted or represented by
Hochiki Europe (UK) Ltd. to be a complete and up-to-date description.
Weatherproof Analogue Addressable
Manual Call Point
HCP-W
Features
Fast response
Status LED
Surface mounting
IP67 rated
Description
Model HCP-W is an IP67 rated Weatherproof Manual Call Point, which is fully compatible with
Hochikis ESP analogue addressable protocol.
The MCP-W incorporates a red LED mounted on the front cover, which can be selected as
pulsing/non-pulsing*1 for communications polling and is continuously lit when the HCP-W is
operated. The unit is operated by pressing the EN54 compliant non-frangible (plastic) element
and, once operated, produces a high level ESP interrupt, allowing the control panel to respond
very quickly. A built in test function initiated by the control panel ensures the integrity of the
device at all times and the device can be tested by insertion of a test key in the underside of
the unit. Two terminal blocks are provided for easy connection to the loop wiring.
The unit is addressed using the TCH-B100 Hand Held Programmer for quick and reliable
addressing and an optional glass element is also available.
Specification
Ordering Code HCP-W
Operating Voltage 17 - 41Vd.c.
Low Power Mode (typ) 85A
Quiescent Current (typ) 230A
Alarm Current (typ) 4.1mA
Transmission Method Digital Communication Using ESP
Operating Temperature Range -10C to + 50C
Storage Temperature Range -30C to + 70C
Maximum Humidity 95%RH - Non Condensing (at 40C)
Ingress Protection Rating IP67
Colour / Case Material Red / Modified Polyphenylene Oxide
Weight (g) / Dimensions (mm) 234 / W98 x H94 x W78
Approval LPCB EN 54-11:2001
*1
Fire alarm control panel compatibility is required for this feature.
Hochiki Europe (UK) Ltd. reserves the right to alter the specification of its products from time to time without notice. Although every
effort has been made to ensure the accuracy of the information contained in this document it is not warranted or represented by
Hochiki Europe (UK) Ltd. to be a complete and up-to-date description.
Weatherproof Analogue Addressable
Manual Call Point
HCP-W(DPS)
Features
Fast response
Status LED
Surface mounting
IP67 Rated
Description
Model HCP-W(DPS) is an IP67 rated Weatherproof Manual Call Point, which is fully compatible
with Hochikis ESP analogue addressable protocol.
The HCP-W(DPS) incorporates a red LED mounted on the front cover, which can be selected as
pulsing/non-pulsing*1 for communications polling and is continuously lit when the HCP-W(DPS)
is operated. The unit is operated by pressing the EN54 compliant non-frangible (plastic)
element and, once operated, produces a high level ESP interrupt, allowing the control panel to
respond very quickly. A built in test function initiated by the control panel ensures the integrity
of the device at all times and the device can be tested by insertion of a test key in the
underside of the unit. Two terminal blocks are provided for easy connection to the loop wiring.
The unit is addressed using the TCH-B100 Hand Held Programmer for quick and reliable
addressing. An optional glass element is also available. The HCP-W(DPS) also incorporates a
change over C Form contact that allows the installer to connect additional equipment to the
Call Point. The C Form contact is non-latching, and will change state when the test key is
inserted, and will return to the original position when the test key is removed.
Specification
Ordering Code HCP-W(DPS)
Operating Voltage 17 - 41Vd.c.
Low Power Mode (typ) 85A (typ)
Quiescent Current (typ) 230A (typ)
Alarm Current (typ) 4.1mA
Contact Rating 24Vd.c. @ 1A (non-inductive)
Transmission Method Digital Communication Using ESP
Operating Temperature Range -10C to + 50C
Storage Temperature Range -30C to + 60C
Maximum Humidity 95%RH - Non Condensing (at 40C)
Ingress Protection Rating IP67
Colour / Case Material Red / Modified Polyphenylene Oxide
Weight (g) / Dimensions (mm) 234 / W98 x H94 x W78
*1
Fire alarm control panel compatibility is required for this feature.
Hochiki Europe (UK) Ltd. reserves the right to alter the specification of its products from time to time without notice. Although every
effort has been made to ensure the accuracy of the information contained in this document it is not warranted or represented by
Hochiki Europe (UK) Ltd. to be a complete and up-to-date description.
Conventional Ultra-Violet Flame Detector
HF-24
Features
Incorporates filter to minimise
unwanted alarms
Description
Model HF-24 Flame Detector detects the presence of a flame within its field of view by
sensing the ultraviolet radiation emitted.
The detector has been designed for internal use and is particularly suited to installations
where flame can be expected to develop initially rather than smoke due to the nature of
combustible materials such as films, video and computer tapes.
Specification
Ordering code HF-24
Operating voltage 15 - 30Vd.c. (Nominal rating 24Vd.c.)
Standby current (typ) 200A at 24Vd.c.
Detection angle 120 Cone
UV sensitivity range 185 to 260nm
Current in alarm state (max) 50mA (with YBF-RL/4H5 Base)
Operating temperature range -10C to +50C
Storage temperature range -30C to +70C
Maximum humidity 95% RH - Non condensing (at 40C)
Ingress Protection Rating IP42
Colour / Case Material Ivory White / ACS
Weight (g) / Diameter (mm) / Height (mm) 152 / 100 / 60
Compatible Base / Height (mm) Hochiki YBF-RL/4H5 / 10
Hochiki Europe (UK) Ltd. reserves the right to alter the specification of its products from time to time without notice. Although every
effort has been made to ensure the accuracy of the information contained in this document it is not warranted or represented by
Hochiki Europe (UK) Ltd. to be a complete and up-to-date description.
Marine Approved Mounting Back Box
Model MBB-1
Features
Glanded cable entry holes
Colour matched
Description
The approved design of the MBB-1 provides a splash proof and secure fixing for the Hochiki
CDX Marine Approved Range of Detectors and their associated Bases. It can be installed on a
variety of different fixing surfaces and because it has been manufactured to match the colour
of Hochiki's range of products, it provides an aesthetically pleasing solution where surface
fixed devices are required.
The housing supports three 20mm glanded entries, for zone, or loop cabling access. It is also
supplied with base fixing screws and two cable glands specifically designed to provide
protection against water ingress.
The detector base fits directly onto the MBB-1 and sits within a slight recess. This provides the
accurate fit and the protection against dust and water ingress.
The MBB-1 is also the recommended choice of back box for Hochikis Waterproof Heat
Detectors, the DFG-60E and the ACB-EW.
Specification
Ordering Code MBB-1
Maximum Humidity 95%RH - Non Condensing (at 40C)
Colour Ivory White
Weight (g) / Diameter (mm) / Height (mm) 123/102/38
YBN-R/3, YBN-R/4M, YBN-R/6, YBN-R/6SK, YBO-
Compatible Bases R/5M, YBO-R/6, YBO-R/6, YBO-R/6RN, YBO-
R/6RS, YBO-R/6PA
Fixing Centres 116mm
Maximum Wire Thickness 2.52mm Cables
Approvals Lloyds, DNV
Hochiki Europe (UK) Ltd. reserves the right to alter the specification of its products from time to time without notice. Although every
effort has been made to ensure the accuracy of the information contained in this document it is not warranted or represented by
Hochiki Europe (UK) Ltd. to be a complete and up-to-date description.
Galvanic Isolator
MTL5061
Features
Description
Model MTL5061 is a zone-powered, two-channel interface for use in conventional fire
detection systems for protection within hazardous areas.
Specification
Ordering Code MTL5061
Safety Description:
Maximum voltage of Zener diode when fuse blows 28V
Minimum value of terminating resistor 300
Maximum short-circuit current 93mA
Number of channels 2
Current Range 1 to 40mA, nominal
Settles to within 500A of final value
Response Time to step input
within 30ms
Maximum Output Voltage in hazardous area 28V (from 300)
Transfer Accuracy at 20C Better than 400A
Temperature Drift <10A/C (-20C to 60C)
Loop Supply Voltage 6 to 35V dc
Quiescent safe-area current at 20C <400A/channel, Vin = 24V dc
Operating Temperature Range -20C to + 60C (continuous working)
Storage Temperature Range -40C to + 80C
Maximum Humidity 95%RH - Non Condensing (at 40C)
Weight (g) / Dimensions (mm) 110 / H110 x W104 x D16
Mounting Method DX070 Box
Description
Model MTL7787+ is an intrinsically safe, zone-powered, Zener-diode barrier for use in
conventional fire detection systems for protection within hazardous areas.
Each Zone contains two stages of pulse-tested Zener or forward- connected diodes and an
'infallible' terminating resistor. In the event of an electrical fault in the safe area, the diodes
limit the voltage that can reach the hazardous area and the resistor limits the current. A
fuse protects the diodes, and the two stages of voltage limitation ensure continued safety if
either stage should fail. No active output-current limiting circuits are employed.
Model MTL7787+ is certified 'ia' for all zones and 'IIC' for all explosive atmospheres.
PLEASE NOTE: The Earth connections to the unit are made via connection to
the DIN rail (this product MUST be earthed.
Specification
Ordering Code MTL7787+
Safety Description:
Maximum voltage of Zener diode when fuse 28V
blows
Minimum value of terminating resistor 300
Maximum short-circuit current 93mA
Number of Channels 2
Maximum end-to-end resistance 333
Working Voltage 26.6V
Maximum Voltage 27.2V
Fuse Rating (continuous) 50mA
Operating Temperature Range -20C to + 60C (continuous working)
Storage Temperature Range -40C to + 80C
Maximum Humidity 95%RH - Non Condensing (at 40C)
Weight (g) / Dimensions (mm) 140 / H90 x W105 x D12.6
Mounting Method DX070 Box
FURTHER INFORMATION: www.mtl-inst.com
Hochiki Europe (UK) Ltd. reserves the right to alter the specification of its products from time to time without notice. Although every
effort has been made to ensure the accuracy of the information contained in this document it is not warranted or represented by
Hochiki Europe (UK) Ltd. to be a complete and up-to-date description.
Surface Mounting Back Box
SBB-1
Features
Glanded cable entry holes
Description
The design of the SBB-1 provides a dust-proof and secure fixing for the Hochiki CDX and ESP
Range of Detectors and Sensors, and their associated Bases. It can be installed on a variety of
different fixing surfaces and because it has been manufactured to match the colour of Hochiki's
range of products, it provides an aesthetically pleasing solution where surface fixed devices are
required.
The housing supports three 20mm glanded entries, for zone, or loop cabling access (glands not
included) and is supplied with base fixing screws.
The detector base fits directly onto the SBB-1 and sits within a slight recess. This provides an
accurate fit and the protection against dust ingress.
Specification
Ordering Code SBB-1
Maximum Humidity 95%RH - Non Condensing (at 40C)
Colour Ivory White
Weight (g) / Diameter (mm) / Height (mm) 123/102/38
YBN-R/3, YBN-R/6, YBN-R/6SK,
Compatible Bases YBO-R/6, YBO-R/6, YBO-R/6RN, YBO-R/6RS,
YBO-R/6PA
Fixing Centres 116mm
Maximum Wire Thickness 2.52mm Cables
Hochiki Europe (UK) Ltd. reserves the right to alter the specification of its products from time to time without notice. Although every
effort has been made to ensure the accuracy of the information contained in this document it is not warranted or represented by
Hochiki Europe (UK) Ltd. to be a complete and up-to-date description.
Duct Probe
SDP-2
Features
Allows air duct sampling using standard
detector or sensor
Simple installation
Description
The SDP-2 is a Duct Probe housing allowing a standard photoelectric smoke detection device,
either a conventional detector or an analogue sensor, to be mounted on the outside of an air
duct for the purpose of monitoring the air within the duct.
Using an aspirating technique, the air within the duct is drawn via a pipe into the duct probes
housing. This allows constant sampling with a standard, LPCB approved smoke detector,
which makes smoke detection within the duct simple, effective and easy to maintain.
Specification
Ordering Code SDP-2
SDP-Lpipe (1500mm)
Sampling pipe ordering codes
SDP-Npipe (600mm)
Duct fixing bracket ordering code SDP-Bracket
Operating Temperature Range -20C to + 50C
Storage Temperature Range -20C to + 70C
Maximum Humidity 99%RH - Non Condensing (at 40C)
Colour / Case Material Green / ABS
IP Rating IP54
Weight (g) / Dimensions (mm) 640 / L280 x W150 x H100
Hochiki Europe (UK) Ltd. reserves the right to alter the specification of its products from time to time without notice. Although every
effort has been made to ensure the accuracy of the information contained in this document it is not warranted or represented by
Hochiki Europe (UK) Ltd. to be a complete and up-to-date description.
Strobe Light
SL-401
Features
Low current consumption
Description
The SL-401 is an ultra-low current strobe light combining excellent efficiency with high light
output. Weatherproofed with a neoprene gasket, the SL-401 is supplied with an anti-tamper
locking device to deter unauthorised removal of the lens.
Specification
Ordering Code SL-401
Operating Voltage 19.2 - 28.8Vdc
Operating Current (typ) 35mA
Operating Temperature Range -20C to 60C
Light Output 0.26 Candella-Seconds
Lens Colour Red
Base Colour Black
Flash Rate 60 - 100 per minute
Weight (g) / Diameter (mm) / Height with base (mm) 130 / 90 / 77
Hochiki Europe (UK) Ltd. reserves the right to alter the specification of its products from time to time without notice. Although every
effort has been made to ensure the accuracy of the information contained in this document it is not warranted or represented by
Hochiki Europe (UK) Ltd. to be a complete and up-to-date description.
Conventional Photoelectric Smoke Detector
SLR-E3
Features
Removable, High Performance chamber
Description
The SLR-E3 is a Photoelectric Smoke Detector, which is fully compatible with the majority of
existing Conventional systems.
The SLR-E3 incorporates Hochikis unique High Performance photoelectric smoke chamber
removing the need to use Ionisation Detectors in the majority of applications. This also allows
the Detector threshold level to be increased, thereby improving the signal to noise ratio and
reducing susceptibility to false alarms. An integral third terminal provides a remote indicator
output.
The smoke chamber is easily removed or replaced for cleaning and utilises a unique baffle
design which allows smoke to enter the chamber whilst keeping out ambient light.
Specification
Ordering Code SLR-E3
Disposable Chamber Yes
Operating Voltage 9.5 - 30Vd.c.
Quiescent Current (typ) 35A
Maximum Current Alarm 40mA
Remote Indicator Drive 20mA (max) / 9.5-14mA (typ)
Operating Temperature Range -10C to + 50C
Storage Temperature Range -30C to + 60C
Maximum Humidity 95%RH - Non Condensing (at 40C)
Ingress Protection Rating IP42
Colour / Case Material Ivory White / ABS
Weight (g) / Diameter (mm) / Height (mm) 95 / 100 / 38
YBN-R6 YBO-R/6R, YBO-R/6RS
Compatible Bases
YBN-R/6SK YBO-R/6RN, YBO-R/6PA
Base Heights (mm) 8 13
Base Fixing Centres (mm) 48 ~ 74
LPCB
Approvals to EN54:2000 Part 7
VdS (G204043)
Hochiki Europe (UK) Ltd. reserves the right to alter the specification of its products from time to time without notice. Although every
effort has been made to ensure the accuracy of the information contained in this document it is not warranted or represented by
Hochiki Europe (UK) Ltd. to be a complete and up-to-date description.
Marine Approved Conventional Photoelectric
Smoke Detector
SLR-E3M
Features
Removable, High Performance chamber
Description
The SLR-E3M is a Marine Approved Photoelectric Smoke Detector, which is fully compatible
with the majority of existing Marine Conventional systems.
The SLR-E3M incorporates Hochikis unique High Performance photoelectric smoke chamber
removing the need to use Ionisation Detectors in the majority of applications. This also allows
the Detector threshold level to be increased, thereby improving the signal to noise ratio and
reducing susceptibility to false alarms. An integral third terminal provides a remote indicator
output.
The smoke chamber is easily removed or replaced for cleaning and utilises a unique baffle
design which allows smoke to enter the chamber whilst keeping out ambient light.
Specification
Ordering Code SLR-E3M
Disposable Chamber Yes
Operating Voltage 9.5 - 30Vd.c.
Quiescent Current (typ) 35A
Maximum Current Alarm 40mA
Remote Indicator Drive 20mA (max) / 9.5-14mA (typ)
Operating Temperature Range -25C to + 70C
Storage Temperature Range -30C to + 60C
Maximum Humidity 95%RH - Non Condensing (at 40C)
Ingress Protection Rating IP42
Colour / Case Material Ivory White / ABS
Weight (g) / Diameter (mm) / Height (mm) 95 / 100 / 38
Compatible Base YBN-R/6M
Base Heights (mm) 8 13
Base Fixing Centres (mm) 48 ~ 74
LPCB, Lloyds Register, Germanischer Lloyd,
Approvals to EN54:2000 Part 7
MCA
Hochiki Europe (UK) Ltd. reserves the right to alter the specification of its products from time to time without notice. Although every
effort has been made to ensure the accuracy of the information contained in this document it is not warranted or represented by
Hochiki Europe (UK) Ltd. to be a complete and up-to-date description.
Intrinsically Safe Conventional
Photoelectric Smoke Detector
SLR-E-IS
Features
Removable, High Performance chamber
Description
Model SLR-E-IS is a Photoelectric Smoke Detector designed for use in hazardous areas which
also incorporates a remote indicator output and a removable chamber for easy maintenance.
Each detector incorporates Hochikis unique High Performance Chamber Technology removing
the need to use Ionisation detectors in the majority of applications.
The High Performance Chamber has also enabled the detector threshold level to be increased,
thereby improving the signal to noise ratio and reducing susceptibility to false alarms.
Specification
Ordering Code SLR-E-IS
Operating Voltage 15 - 30Vd.c.
Quiescent Current (typ) 50A
Maximum Current In Alarm 50mA
Operating Temperature Range -10C to + 50C
Storage Temperature Range -30C to + 70C
Maximum Humidity 95%RH - Non Condensing (at 40C)
Ingress Protection Rating IP42
Colour / Case Material Ivory White / ABS
Weight (g) / Diameter (mm) / Height (mm) 115 / 100 / 38
Compatible Base / Base Height (mm) YBN-R/4(IS) / 8
Base Fixing Centres (mm) 48 ~ 74
LPCB
Approvals Germanischer Lloyd
ATEX BAS01ATEX1281
Hochiki Europe (UK) Ltd. reserves the right to alter the specification of its products from time to time without notice. Although every
effort has been made to ensure the accuracy of the information contained in this document it is not warranted or represented by
Hochiki Europe (UK) Ltd. to be a complete and up-to-date description.
Optical Beam Smoke Detector
SPB-ET
Features
5 - 100m range
Automatic compensation
Test filters
Approved by LPCB
Description
Model SPB-ET is a two wire beam smoke detector that consists of an emitter and receiver that
cover a distance of 5 - 100m providing a maximum coverage of 1500m2. The emitter and
receiver are synchronised via a two-wire link, which also supplies power to the emitter.
The detector is powered directly from the zone (no auxiliary power supplies are required) and
when the zone is reset the detector is reset automatically. The SPB-ET can also be interfaced
to Hochikis ESP system by using a CHQ-MZ Mini Zone Monitor or a CHQ-Z Dual Zone Monitor.
The SPB-ET comes complete with a termination module which fits directly on to a standard U.K
dual back box, this allows the detector be surface or flush mounted. Line continuity options can
be selected on the termination module and these are based on the Schottky or Zener diode
method.
Specification
Ordering Code SPB-ET*
Operating Voltage 15 - 33Vd.c.
Quiescent Current (typ) 240A
Maximum Current In Alarm 50mA
Operation Range 5 - 100m (between emitter & receiver)
Sensitivity Range 25%, 50% and 70% obscuration (selectable)
Operating Temperature Range -10C to +50C
Storage Temperature Range -30C to +70C
Maximum Humidity 95%RH - Non condensing (at 40C)
Colour / Case Material Ivory White / ACS
(Receiver) 685 / H140 x W86 x D101
Weight (g) / Dimensions (mm)
(Emitter) 600 / H140 x W86 x D101
Line Continuity Options (Interface Kit) Schottky/Zener
Approval LPCB (BS5839 Part 5)
Hochiki Europe (UK) Ltd. reserves the right to alter the specification of its products from time to time without notice. Although every
effort has been made to ensure the accuracy of the information contained in this document it is not warranted or represented by
Hochiki Europe (UK) Ltd. to be a complete and up-to-date description.
Reflective Beam Smoke Detector
SRA-ET
Features
5 - 30m range
Automatic compensation
Description
Model SRA-ET is a reflective beam smoke detector consisting of an emitter/receiver unit and
reflector plate that works over a distance of 5 - 30m, providing a maximum coverage of
450m2.
The detector is powered directly from the zone, so no auxiliary power supplies are required, so
when the zone is reset the detector is reset automatically. The SRA-ET can also be interfaced
onto Hochikis ESP systems by using a CHQ-MZ Mini Zone Monitor or a CHQ-Z Dual Zone
Monitor. The SRA-ET comes complete with a Reflector and Termination Module which fits
directly on to a standard U.K. dual back box, this allows the detector be surface or flush
mounted. Line continuity options can be selected on the termination module and these are
based on the Schottky or Zener diode method.
The SRA-ET is not solar blind so care should be taken when installing the detector as false
alarms may occur. In areas affected by sunlight the Hochiki SPB-ET Beam Detector should be
employed.
Specification
Ordering Code SRA-ET
Operating Voltage 15 - 30Vd.c.
Quiescent Current (typ) 350A
Maximum Current In Alarm 50mA
Operation Range (m) 5 - 30
Sensitivity 30%
Operating Temperature Range -10C to +50C
Storage Temperature Range -30C to +70C
Maximum Humidity 95%RH - Non condensing (at 40C)
Colour / Case Material Ivory White / ABS
(SRA-ET) 700 / H152 x W122 x D80
Weight (g) / Dimensions (mm)
(Reflector) 50 / H190 x W190 x D3
Line Continuity Options (Interface Kit) Schottky/Zener
LPCB BS5839 Part 5 / prEN54 Part 12
Approvals
VdS prEN54 Part 12
Hochiki Europe (UK) Ltd. reserves the right to alter the specification of its products from time to time without notice. Although every
effort has been made to ensure the accuracy of the information contained in this document it is not warranted or represented by
Hochiki Europe (UK) Ltd. to be a complete and up-to-date description.
ESP Device Address Programmer
TCH-B100
Features
Lightweight Design
Description
Model TCH-B100 is a hand held address programmer designed to address the ESP range of
Sensors and other addressable devices such as the CHQ-BS Base Sounder.
The unit is designed to be light, robust and easy to use and operates from a single PP3 size
battery, which gives the capacity for up to 8000 operations; the programmer is also capable of
displaying the sensor analogue values.
Specification
Ordering Code TCH-B100
Battery Type 9Vd.c.
Operating Temperature Range -10C to +50C
Colour / Case Material White / ABS
Weight (g) / Dimensions (mm) 140 (Including Battery) / L160 x D30 x W99.5
Hochiki Europe (UK) Ltd. reserves the right to alter the specification of its products from time to time without notice. Although every
effort has been made to ensure the accuracy of the information contained in this document it is not warranted or represented by
Hochiki Europe (UK) Ltd. to be a complete and up-to-date description.
Loop Commissioning Tool
TE-LCT
Features
Assists in the determination of Earth, Open
and Short Circuit faults on loop cabling
Description
The Hochiki Loop Commissioning Tool, model TE-LCT, is a powerful yet easy to use loop
installation and commissioning device. It has been designed to allow System Engineers to
verify and test loops of Hochiki ESP devices before the control panel is installed/
commissioned. This enables the engineer to quickly determine the presence of cable faults
and device operation.
The TE-LCTs software is menu-driven providing an easy-to-use interface. The menu system
also provides online help.
Specification
Ordering Code TE-LCT
Power Supply 12Vd.c. 1.5Ah NiMH internal battery pack
Display Graphical Liquid Crystal Display (with backlight)
Resistance Measurement 1 - 400 (within a tolerance of 10%)
Current Drive (typ) 100mA
Operating Temperature Range +5C to +35C
Operating Humidity 5% to 95% RH @ 40C
Colour / Case Material Grey / ABS with polyester keypad membrane
Weight (g) / Dimensions (mm) 983 / L185 x W135 x D60
Hochiki Europe (UK) Ltd. reserves the right to alter the specification of its products from time to time without notice. Although every
effort has been made to ensure the accuracy of the information contained in this document it is not warranted or represented by
Hochiki Europe (UK) Ltd. to be a complete and up-to-date description.
True Loop Emulator
TE-TLE
Features
Allows simulation of up to 4 loops of Hochiki
analogue devices (127 per loop)
Description
The TE-TLE is a 'virtual' loop device. Once the Fire Alarm Control Panel is connected to the
computer via the Interface, a 'virtual' loop can be created within the True Loop Emulator
software.
Devices can be selected and 'placed' on addresses on the loop. These devices can then be
activated with a number of different actions such as 'fire' or 'short-circuit' conditions, to test
the panel's reactions and programming. In this way, a complete fire detection system can be
tested and proven before any actual hardwiring commences, saving time and resources.
Each Interface can handle up to four loops of devices and the software can handle one or two
Interfaces. Thus, up to eight loops of devices can be emulated simultaneously.
Specification
Ordering code TE-TLE
Input voltage range 240Va.c.
Interface: Power supply
Output voltage 12Vd.c.
Operating System Windows 95, 98, NT & 2000
Software:
Capability Supports 8 loops (via 2 interfaces)
Weight (Kg) / Dimensions (mm) 2.41 / W350 x H100 x D255
Hochiki Europe (UK) Ltd. reserves the right to alter the specification of its products from time to time without notice. Although every
effort has been made to ensure the accuracy of the information contained in this document it is not warranted or represented by
Hochiki Europe (UK) Ltd. to be a complete and up-to-date description.
Surface Wiring Adaptor
Model YBD-RA
Features
Compatible with the majority of existing
Analogue and Conventional bases
Description
The YBD-RA Surface Wiring Adaptor allows the majority of Hochiki Sensors/Detectors and their
Mounting Bases to be fitted flush against a fixing surface whilst also allowing surface wiring
(without conduit) to be connected.
The adaptor features four 9mm x 8mm knock-outs for cables/wires allowing surface-fixed
wiring to be connected to an appropriate mounting base (depending on application). The
adaptor is moulded in ivory white ABS as standard, which allows seamless integration with the
majority of mounting bases and associated sensors and detectors.
Specification
Ordering Code YBD-RA
Maximum Humidity 95%RH - Non Condensing (at 40C)
Colour Ivory White
Weight (g) / Diameter (mm) / Height (mm) 27 / 110 / 16
Fixing Centres (mm) 61 ~ 89
Maximum Wire Thickness 2.5mm2 Cables
Hochiki Europe (UK) Ltd. reserves the right to alter the specification of its products from time to time without notice. Although every
effort has been made to ensure the accuracy of the information contained in this document it is not warranted or represented by
Hochiki Europe (UK) Ltd. to be a complete and up-to-date description.
Analogue Common Mounting Base
YBN-R/3
Features
Electronics free
Description
Model YBN-R/3 is a Common Mounting Base, which is fully compatible with Hochikis ESP
range of sensors.
It is supplied with square cable clamps for secure and reliable cable termination and is also
capable of driving a remote LED if required.
Specification
Ordering Code YBN-R/3
Operating Temperature Range -10C to + 50C
Storage Temperature Range -30C to + 70C
Maximum Humidity 95%RH - Non Condensing (at 40C)
Colour / Material Ivory White / ABS
Weight (g) / Diameter (mm) / Height (mm) 50 / 100 / 8
Fixing Centres (mm) 48 ~ 74
Maximum Wire Thickness 2.52mm Cables
Hochiki Europe (UK) Ltd. reserves the right to alter the specification of its products from time to time without notice. Although every
effort has been made to ensure the accuracy of the information contained in this document it is not warranted or represented by
Hochiki Europe (UK) Ltd. to be a complete and up-to-date description.
Conventional Intrinsically Safe
Mounting Base
YBN-R/4(IS)
Features
Low Profile, only 8mm
Rugged design
Electronics free
Description
Model YBN-R/4(IS) is a Conventional Detector Mounting Base associated with the CDX Range
of Intrinsically Safe Detectors and is fully compatible with the majority of existing
conventional fire alarm control panels.
It is supplied with square cable clamps for secure and reliable cable termination but the base
does not provide line continuity during detector removal, therefore if Call Points are being
used then these should be wired onto the zone first.
Specification
Ordering Code YBN-R/4(IS)
Maximum Humidity 95%RH - Non Condensing (at 40C)
Colour / Material Ivory White / ABS
Weight (g) / Diameter (mm) / Height (mm) 51 / 100 / 8
Fixing Centres (mm) 48 ~ 74
Maximum Wire Thickness 2.52mm Cables
Hochiki Europe (UK) Ltd. reserves the right to alter the specification of its products from time to time without notice. Although every
effort has been made to ensure the accuracy of the information contained in this document it is not warranted or represented by
Hochiki Europe (UK) Ltd. to be a complete and up-to-date description.
Conventional Electronics Free
Mounting Base
YBN-R/6
Features
Integral remote indicator output
Rugged design
Electronics free
Description
Model YBN-R/6 is a Conventional Detector Mounting Base associated with the CDX Range of
Detectors and is fully compatible with the majority of existing conventional fire alarm control
panels.
It is supplied with square cable clamps for secure and reliable cable termination but the base
does not provide line continuity during detector removal, therefore if Call Points are being
used then these should be wired onto the zone first. The integrated third terminal provides
remote indicator output.
Specification
Ordering Code YBN-R/6
Operating Voltage 9.5 - 30Vd.c.
Operating Temperature Range -10C to + 50C
Storage Temperature Range -30C to + 60C
Maximum Humidity 95%RH - Non Condensing (at 40C)
Colour / Material Ivory White / ABS
Weight (g) / Diameter (mm) / Height (mm) 51 / 100 / 8
Fixing Centres (mm) 48 ~ 74
Hochiki Europe (UK) Ltd. reserves the right to alter the specification of its products from time to time without notice. Although every
effort has been made to ensure the accuracy of the information contained in this document it is not warranted or represented by
Hochiki Europe (UK) Ltd. to be a complete and up-to-date description.
Marine Approved Conventional Electronics
Free Mounting Base
Model YBN-R/6M
Features
Integral remote indicator output
Rugged design
Electronics free
Description
Model YBN-R/6M is a Conventional Detector Mounting Base approved for marine applications
by LRS and DNV and is associated with the CDX Range of Marine Approved Detectors.
It is supplied with square cable clamps for secure and reliable cable termination but the base
does not provide line continuity during detector removal, therefore if Call Points are being used
then these should be wired onto the zone first. The integrated third terminal provides remote
indicator output.
Specification
Operating Code YBN-R/6M
Maximum Humidity 95%RH - Non Condensing (at 40C)
Colour / Material Ivory White / ABS
Diameter (mm) / Height (mm) 100 / 8
Fixing Centres (mm) 48 ~ 74
Maximum Wire Thickness 2.5mm2 Cables
Hochiki Europe (UK) Ltd. reserves the right to alter the specification of its products from time to time without notice. Although every
effort has been made to ensure the accuracy of the information contained in this document it is not warranted or represented by
Hochiki Europe (UK) Ltd. to be a complete and up-to-date description.
Conventional Schottky Diode
Mounting Base
YBN-R/6SK
Features
Integral remote indicator output
Rugged design
Description
Model YBN-R/6SK is a Conventional Detector Mounting Base with in-line Schottky Diode,
associated with the CDX Range of Detectors and is fully compatible with the majority of
existing conventional fire alarm control panels.
It is supplied with square cable clamps for secure and reliable cable termination and the base
provides line continuity during detector removal. Therefore Call Points can be wired in any
order on the zone providing a suitable panel and End Of Line (EOL) unit is used. The
integrated third terminal provides remote indicator output.
Specification
Ordering Code YBN-R/6SK
Operating Voltage 15 - 30Vd.c.
Operating Temperature Range -10C to + 50C
Storage Temperature Range -30C to + 60C
Maximum Humidity 95%RH - Non Condensing (at 40C)
Colour / Material Ivory White / ABS
Weight (g) / Diameter (mm) / Height (mm) 52 / 100 / 8
Fixing Centres (mm) 48 ~ 74
Hochiki Europe (UK) Ltd. reserves the right to alter the specification of its products from time to time without notice. Although every
effort has been made to ensure the accuracy of the information contained in this document it is not warranted or represented by
Hochiki Europe (UK) Ltd. to be a complete and up-to-date description.
Recess Base Adaptor
YBN-UA
Features
Allows base and analogue sensor or
conventional detector to be flush mounted
Description
Model YBN-UA is a mounting adaptor for both the ESP and CDX Range of sensors and
Detectors and their associated mounting bases. The YBN-UA allows a base and head
combination to be flush mounted by providing a recess fixing the ceiling.
It is supplied with a fixing clamp kit (YYA-1) which secures the YBN-UA within a pre-cut hole
up to a maximum ceiling thickness of 30mm.
Specification
Ordering Code YBN-UA
Operating Temperature Range -10C to + 50C
Storage Temperature Range -30C to + 60C
Maximum Humidity 95%RH - Non Condensing (at 40C)
Colour / Material Ivory White / ABS
Weight (g) / Diameter (mm) / Height (mm) 65 / 140 / 44
Height when fitted flush (mm) 7
Drilled Hole Size (mm) 115
Compatible Bases All YBN Range, YBO-R/5 Range, YBO-R/6
Range, YBO-R/4 Range
Fixing Centres (mm) 48 ~ 74
Hochiki Europe (UK) Ltd. reserves the right to alter the specification of its products from time to time without notice. Although every
effort has been made to ensure the accuracy of the information contained in this document it is not warranted or represented by
Hochiki Europe (UK) Ltd. to be a complete and up-to-date description.
Analogue Addressable Base Sounder
YBO-BS
Features
Loop Powered with Single Loop Address -
addressed automatically by Control Panel or via
the TCH-B100 Hand Held Programmer
Description
Model YBO-BS is an addressable loop powered Base Sounder innovatively designed to give a range
of tones and volumes with a maximum output of up to 98dB(A) (2dB(A)) with low current
consumption. The unit is designed to fit to the Standard Base (YBN-R/3) or the Isolator Base
(YBO-R/SCI from Batch Number 6044) and can be fitted with any of the ESP Range of Sensors,
Beacons or Remote Indicators. The unit can also be converted into a wall sounder with the simple
addition of a Cap (SI/CAP). The sounder is Ingress Protection rated to IP21 and for internal use
only. An Auto-Shutdown feature allows the user to set a fixed time within which the sounder will
operate, before automatically silencing itself, cutting noise pollution.
Specification
Ordering Codes YBO-BS
YBO-BS(WHT)
SI/CAP
Operating Voltage 17 ~ 41Vd.c.
Low Power Mode (typ) 40A
Quiescent Current (typ) 150A
Sounding Current (typ) 0.8mA (50dB(A) @ 1m) ~ 16mA (98dB(A) @ 1m)
50 ~ 98dB(A) (2dB(A)) @ 24Vd.c. or above
Sound Output (at 1 metre)
(EN54-3 compliant)
Number of Tones 51
Tone Frequency Range 300Hz ~ 2850Hz
Operating Temperature Range -10C to +50C
Storage Temperature Range -30C to +70C
Maximum Humidity 95%RH - Non Condensing (at 40C)
Colour / Case Material Ivory / PC+PS+GF5
Ingress Protection Rating IP21
Weight (g) / Dimensions (mm) 112 / H113 x W113 x D43
Base Fixing Centres (mm) 48 ~ 74
Note: Although the TCH-B100 Hand Held Programmer will allow addresses between 128
and 254 to be programmed into the YBO-BS, addresses 1 to 127 ONLY should be used.
Hochiki Europe (UK) Ltd. reserves the right to alter the specification of its products from time to time without notice. Although every effort has
been made to ensure the accuracy of the information contained in this document it is not warranted or represented by Hochiki Europe (UK)
Ltd. to be a complete and up-to-date description.
Analogue Addressable Base Sounder Beacon
YBO-BSB
Features
Loop Powered with Single Loop Address -
addressed automatically by Control Panel or via
the TCH-B100 Hand Held Programmer
Description
Model YBO-BSB is an addressable loop powered Base Sounder with integral Beacon, innovatively
designed to give a range of tones and volumes with a maximum output of up to 98dB(A)
(2dB(A)) with low current consumption. The unit is designed to fit to the Standard Base (YBN-
R/3) or the Isolator Base (YBO-R/SCI from Batch Number 6044) and can be fitted with any of
the ESP Range of Sensors, Beacons or Remote Indicators. The unit can also be converted into a
wall sounder beacon with the simple addition of a Cap (SI/CAP). The sounder is Ingress
Protection rated to IP21 and for internal use only. An Auto-Shutdown feature allows the user to
set a fixed time within which the sounder or beacon will operate, before automatically shutting
down, cutting noise pollution in the case of the sounder element*. Sounder and Beacon elements
can be operated independently from each other*.
*dependent on Control Panel compatibility
Specification
Ordering Codes YBO-BSB / YBO-BSB(WHT) / SI/CAP
Operating Voltage 17 ~ 41Vd.c.
Low Power Mode (typ) 110A
Quiescent Current (typ) 250A
Sounding Current (typ) 1.3mA (50dB(A) @ 1m) ~ 21mA (98dB(A) @ 1m)
50 ~ 98dB(A) (2dB(A)) @ 24Vd.c. or above
Sound Output (at 1 metre)
(EN54-3 compliant)
Number of Tones 51
Tone Frequency Range 300Hz ~ 2850Hz
Operating Temperature Range -10C to +50C
Storage Temperature Range -30C to +70C
Maximum Humidity 95%RH - Non Condensing (at 40C)
Colour / Case Material Ivory / PC+PS+GF5
Lens Material Translucent PC
Ingress Protection Rating IP21
Weight (g) / Dimensions (mm) 160 / H113 x W113 x D43
Base Fixing Centres (mm) 48 ~ 74
Note: Although the TCH-B100 Hand Held Programmer will allow addresses between 128
and 254 to be programmed into the YBO-BS, addresses 1 to 127 ONLY should be used.
Hochiki Europe (UK) Ltd. reserves the right to alter the specification of its products from time to time without notice. Although every effort has
been made to ensure the accuracy of the information contained in this document it is not warranted or represented by Hochiki Europe (UK)
Ltd. to be a complete and up-to-date description.
12 Volt Mounting Base
YBO-R/12V
Features
Low Profile
Rugged design
Description
Model YBO-R/12V is a base suitable for use on most 12-volt security systems, this base
allows mounting of any of the CDX range detectors (excluding the HF-24) giving the user the
ability to use approved Smoke and Heat Detectors.
The base incorporates a volt free relay changeover contact that can easily be configured as
either normally open or normally closed
Specification
Operating Code YBO-R/12V
Operating Voltage 10 to 15Vd.c.
Quiescent Current (typ) 230A
Maximum Current in Alarm 50mA (including remote indicator)
Remote Indicator Current 6-10mA (across voltage range)
Relay Contacts SPST N/O or N/C
Relay Contact Ratings 24V DC @ 1A
Operating Temperature Range -10C to +50C
Maximum Humidity 95%RH - Non Condensing (at 40C)
Colour / Material Ivory White / ABS
Weight (g) / Diameter (mm) / Height (mm) 50 / 100 / 13
Fixing Centres (mm) 48 ~ 74
Hochiki Europe (UK) Ltd. reserves the right to alter the specification of its products from time to time without notice. Although every
effort has been made to ensure the accuracy of the information contained in this document it is not warranted or represented by
Hochiki Europe (UK) Ltd. to be a complete and up-to-date description.
Conventional Remote Indicator
Mounting Base
YBO-R/5
Features
Low Profile
Rugged design
Description
Model YBO-R/5 is a Conventional Detector Remote Indicator Mounting Base associated with the
CDX Range of Detectors and is fully compatible with the majority of existing Conventional fire
alarm control panels.
The base has the capability of driving a remote fire LED if required.
Specification
Operating Code YBO-R/5
Operating Temperature Range -10C to +50C
Maximum Humidity 95%RH - Non Condensing (at 40C)
Colour Ivory White
Weight (g) / Diameter (mm) 100mm
Height 13mm
Fixing Centres 48mm through to 74mm
Hochiki Europe (UK) Ltd. reserves the right to alter the specification of its products from time to time without notice. Although every
effort has been made to ensure the accuracy of the information contained in this document it is not warranted or represented by
Hochiki Europe (UK) Ltd. to be a complete and up-to-date description.
Conventional Schottky
Line Continuity Base (Safeline)
YBO-R/5SK
Features
Low Profile
Rugged design
Description
Model YBO-R/5SK is a Conventional Detector Mounting Base associated with the CDX Range of
Detectors and is fully compatible with the majority of existing Conventional fire alarm control
panels.
The base is capable of providing full line continuity during detector removal via a Schottky
Diode and this meets the requirements of BS5839, the base also has the capability of driving a
remote fire LED if required.
Specification
Ordering Code YBO-R/5SK
Maximum Humidity 95%RH - Non Condensing (at 40C)
Colour / Material Ivory White / ABS
Weight (g) / Diameter (mm) / Height (mm) 87 / 100 / 8
Fixing Centres (mm) 48 ~ 74
Maximum Wire Thickness 2.5mm2 Cables
Hochiki Europe (UK) Ltd. reserves the right to alter the specification of its products from time to time without notice. Although every
effort has been made to ensure the accuracy of the information contained in this document it is not warranted or represented by
Hochiki Europe (UK) Ltd. to be a complete and up-to-date description.
Conventional Zener Line Continuity
Base (Liveline)
YBO-R/5ZD
Features
Low Profile
Rugged design
Description
Model YBO-R/5ZD is a Conventional Detector Mounting Base associated with the CDX Range of
Detectors and is fully compatible with the majority of existing Conventional fire alarm control
panels.
The base is capable of providing full line continuity during detector removal via a patented
Zener Diode circuit and this meets the requirements of BS5839, the base also has the
capability of driving a remote fire LED if required.
Specification
Ordering Code YBO-R/5ZD
Operating Voltage 15 - 30Vdc
Operating Temperature Range -10C to + 50C
Storage Temperature Range -30C to + 60C
Maximum Humidity 95%RH - Non Condensing (at 40C)
Colour / Material Ivory White / ABS
Weight (g) / Diameter (mm) / Height (mm) 75 / 100 / 8
Fixing Centres (mm) 48 ~ 74
Maximum Wire Thickness 2.5mm2 Cables
Hochiki Europe (UK) Ltd. reserves the right to alter the specification of its products from time to time without notice. Although every
effort has been made to ensure the accuracy of the information contained in this document it is not warranted or represented by
Hochiki Europe (UK) Ltd. to be a complete and up-to-date description.
Conventional Detector Mounting Base
for 2-Wire Systems
YBO-R/6PA
Features
Integral remote indicator output
Rugged design
Description
Model YBO-R/6PA is a Conventional Detector Mounting Base for 2-Wire S systems where
detectors and sounders are on same zone cables*.
Specification
Ordering Code YBO-R/6PA
Operating Voltage 15 - 30Vdc
Operating Temperature Range -10C to + 50C
Storage Temperature Range -30C to + 60C
Maximum Humidity 95%RH - Non Condensing (at 40C)
Colour / Material Ivory White /ABS
Weight (g) / Diameter (mm) / Height (mm) 80 / 100 / 13
Fixing Centres (mm) 48 ~ 74
Maximum Wire Thickness 2.5mm2 Cables
Hochiki Europe (UK) Ltd. reserves the right to alter the specification of its products from time to time without notice. Although every
effort has been made to ensure the accuracy of the information contained in this document it is not warranted or represented by
Hochiki Europe (UK) Ltd. to be a complete and up-to-date description.
Conventional Latching Relay Mounting Base
YBO-R/6R
Features
Integral remote indicator output
Rugged design
Description
Model YBO-R/6R is a Conventional Detector Mounting Base associated with the New CDX
Range of Detectors and is fully compatible with the majority of existing conventional fire alarm
and security control panels.
It is supplied with square cable clamps for secure and reliable cable termination but the base
does not provide line continuity during detector removal, therefore if Call Points are being used
then these should be wired onto the zone first. The integrated third terminal provides remote
indicator output.
Specification
Ordering Code YBO-R/6R
Operating Voltage 9.5 - 30Vd.c.
Relay Voltage 30Vdc @ 1A (non-inductive)
Operating Temperature Range -10C to + 50C
Storage Temperature Range -30C to + 60C
Maximum Humidity 95%RH - Non Condensing (at 40C)
Colour / Material Ivory White / ABS
Weight (g) / Diameter (mm) / Height (mm) 87 / 100 / 13
Fixing Centres (mm) 48 ~ 74
Maximum Wire Thickness 2.5mm2 Cables
Hochiki Europe (UK) Ltd. reserves the right to alter the specification of its products from time to time without notice. Although every
effort has been made to ensure the accuracy of the information contained in this document it is not warranted or represented by
Hochiki Europe (UK) Ltd. to be a complete and up-to-date description.
Conventional Non-Latching Relay
Mounting Base
YBO-R/6RN
Features
Integral remote indicator output
Rugged design
Description
Model YBO-R/6RN is a Conventional Detector Mounting Base associated with the New CDX
Range of Detectors and is fully compatible with the majority of existing conventional fire alarm
and security control panels.
It is supplied with square cable clamps for secure and reliable cable termination but the base
does not provide line continuity during detector removal, therefore if Call Points are being used
then these should be wired onto the zone first. The integrated third terminal provides remote
indicator output.
Specification
Ordering Code YBO-R/6RN
Operating Voltage 9.5 - 30Vd.c.
Relay Voltage 30Vd.c. @ 1A (non-inductive)
Operating Temperature Range -10C to + 50C
Storage Temperature Range -30C to + 60C
Maximum Humidity 95%RH - Non Condensing (at 40C)
Colour / Material Ivory White / ABS
Weight (g) / Diameter (mm) / Height (mm) 87 / 100 / 13
Fixing Centres (mm) 48 ~ 74
Maximum Wire Thickness 2.5mm2 Cables
Hochiki Europe (UK) Ltd. reserves the right to alter the specification of its products from time to time without notice. Although every
effort has been made to ensure the accuracy of the information contained in this document it is not warranted or represented by
Hochiki Europe (UK) Ltd. to be a complete and up-to-date description.
Conventional Latching Schottky Diode Relay
Mounting Base
YBO-R/6RS
Features
Integral remote indicator output
Rugged design
Description
Model YBO-R/6RS is a Conventional Detector Mounting Base associated with the New CDX
Range of Detectors and is fully compatible with the majority of existing conventional fire alarm
control panels.
It is supplied with square cable clamps for secure and reliable cable termination and the base
provides line continuity during detector removal. Therefore if Call Points can be wired in any
order on the zone providing a suitable panel and End Of Line (EOL) unit is used. The
integrated third terminal provides remote indicator output.
Specification
Ordering Code YBO-R/6RS
Operating Voltage 9.5 - 30Vd.c.
Relay Voltage 30Vd.c. @ 1A (non-inductive)
Operating Temperature Range -10C to + 50C
Storage Temperature Range -30C to + 60C
Maximum Humidity 95%RH - Non Condensing (at 40C)
Colour / Material Ivory White / ABS
Weight (g) / Diameter (mm) / Height (mm) 87 / 100 / 13
Fixing Centres (mm) 48 ~ 74
Maximum Wire Thickness 2.5mm2 Cables
Hochiki Europe (UK) Ltd. reserves the right to alter the specification of its products from time to time without notice. Although every
effort has been made to ensure the accuracy of the information contained in this document it is not warranted or represented by
Hochiki Europe (UK) Ltd. to be a complete and up-to-date description.
Short-Circuit Isolator Base
YBO-R/SCI
Features
Detects short circuits on loop
Status LED
Description
Model YBO-R/SCI is a Loop Isolator, which is fully compatible with Hochikis ESP analogue
addressable protocol.
The YBO-R/SCI Base is compatible with any of the ESP Sensors, and can be used instead of
the standard YBN-R/3 Base, this reduces the cost of the Short Circuit Isolators and improves
the functionality. The Base incorporates an amber LED to show when it is isolating a section of
the loop, and if used under every analogue Sensor on the loop, none would be lost if a single
short circuit was to occur.
The YBO-R/SCI does not use an address, and has the same wiring configuration as the YBN-
R/3 Sensor Base making it very simple to install. The YBO-R/SCI can also be used without a
Sensor; a cover can be fitted to conceal the wiring connections (see below). The device is also
available as a DIN Rail mountable unit.
Specification
YBO-R/SCI (Base)
Ordering Codes CHQ-SCI/DIN (Din Rail Version)
S/I-BC (Base Cover)
Operating Voltage 17 - 41Vd.c.
Quiescent Current (typ) 50A
Current In Short Circuit <10mA
Maximum Short Circuit Current 1A
Operating Temperature Range -10C to + 50C
Storage Temperature Range -30C to + 60C
Maximum Humidity 95%RH - Non Condensing (at 40C)
(Base) Ivory White / ABS
Colour / Case Material
(DIN Rail Version) Green / ABS
Maximum Number of Isolators per Loop 127
(Base) 85 / 100 (diameter) / H13
Weight (g) / Dimensions (mm)
(DIN Rail Version) 122 / L119 x W24 x H108
Fixing Centres (mm) 48 ~ 74
Approvals LPCB
VdS (G204048)
Hochiki Europe (UK) Ltd. reserves the right to alter the specification of its products from time to time without notice. Although every
effort has been made to ensure the accuracy of the information contained in this document it is not warranted or represented by
Hochiki Europe (UK) Ltd. to be a complete and up-to-date description.
Analogue Addressable Short Circuit Isolator
(Negative-Switching)
YBO-R/SCI(NS)
Features
Detects short circuits on loop
Status LED
Description
Model YBO-R/SCI(NS) is a negative-switching* Loop Isolator, which is fully compatible with
Hochikis ESP analogue addressable protocol.
The YBO-R/SCI(NS) Base is compatible with any of the ESP Sensors, and can be used instead
of the standard YBN-R/3 Base, this reduces the cost of the Short Circuit Isolators and improves
the functionality. The Base incorporates an amber LED to show when it is isolating a section of
the loop, and when used under each analogue Sensor if a single short circuit was to occur on
the loop then no Sensors would be lost. The YBO-R/SCI(NS) does not use an address, and has
the same wiring configuration as the YBN-R/3 Sensor Base making it very simple to install. The
YBO-R/SCI can also be used without a Sensor; in this case a cover should be fitted to conceal
the wiring connections.
NOTE: Only this model of isolator can be used on systems featuring the BGU-E Call Point Isolator. Positive-Switching
and Negative-Switching devices should never be mixed within the same system.
Specification
Ordering Code YBO-R/SCI(NS)
Ordering Code for Cover S/I-BC
Operating Voltage 17 - 41Vd.c.
Quiescent Current (typ) 50A
Current In Short Circuit <10mA
Maximum Short Circuit Current 1A
Operating Temperature Range -10C to + 50C
Maximum Humidity 95%RH - Non Condensing (at 40C)
Maximum Number of Isolators per Loop 127
Colour / Material Ivory White / ABS
Weight (g) / Diameter (mm) / Height (mm) 85 / 100 / 13
Fixing Centres (mm) 48 ~ 74
Maximum Wire Thickness 2.5mm2 Cables
*NOTE: Check Control Panel compatibility in regards to Negative-Switching before using this product.
Hochiki Europe (UK) Ltd. reserves the right to alter the specification of its products from time to time without notice. Although every
effort has been made to ensure the accuracy of the information contained in this document it is not warranted or represented by
Hochiki Europe (UK) Ltd. to be a complete and up-to-date description.
Addressable Detector Base
YCA-RL/3H2
Features
Low Profile
Rugged design
Description
Model YCA-RL/3H2 is an addressable base designed to allow the CD and CDX range of
detectors (excluding the HF-24) to be connected to Hochikis ESP analogue addressable
system, the base also allows the connection of a remote indicator if required.
Full monitoring against malfunction or disconnection, together with a self-test feature through
the ESP protocol, ensures the integrity of the YCA-RL/3H2 at all times.
The YCA-RL/3H2 utilises simple DIL switches for reliable addressing, the base also incorporates
an LED, which is illuminated when the detector connected to the base goes into alarm.
Flashing of the LED when the control panel polls the base is selectable by bit 8 of the DIL
switch
Specification
Ordering Code YCA-RL/3H2
Operating Voltage 17 - 41Vd.c.
Low Power Mode (typ) 110A
Quiescent Current (typ) 300A
Alarm Current (typ) 15mA (with remote LED on)
Transmission Method Digital Communication using ESP
Operating Temperature Range -10C to +50C
Storage Temperature Range -30C to +60C
Maximum Humidity 95%RH - Non Condensing (at 40C)
Colour Case / Material Ivory White / ABS
Weight (g) / Diameter (mm) 75 / 100
Fixing Centres (mm) 48 ~ 74
Please Note: As of 1st January 2001, this product will be available only
on a Maintenance Replacement basis.
Hochiki Europe (UK) Ltd. reserves the right to alter the specification of its products from time to time without notice. Although every
effort has been made to ensure the accuracy of the information contained in this document it is not warranted or represented by
Hochiki Europe (UK) Ltd. to be a complete and up-to-date description.
Addressable Master Base
YCA-RL/5H2
Features
Low Profile
Rugged design
Description
Model YCA-RL/5H2 is an addressable base designed to allow the CD and CDX range of
detectors to be connected to Hochikis ESP analogue addressable system. The YCA-RL/5H2
also allows the connection of up to five Hochiki slave detectors on a slave line, however if the
HF-24 is being used, then no slave detectors may be fitted.
Full monitoring against malfunction or disconnection, together with a self-test feature through
the ESP protocol, ensures the integrity of the YCA-RL/5H2 at all times. The slave line is also
monitored for detector removal or cable open circuits.
The YCA-RL/5H2 utilises simple DIL switches for reliable addressing, the base also incorporates
an LED which is illuminated when the detector connected to the Master Base goes into alarm.
Specification
Ordering Code YCA-RL/5H2
Operating Voltage 17 - 41Vd.c.
Low Power Mode (typ) 185A
Quiescent Current (typ) 300A
Alarm Current (typ) 38mA (with remote LED on)
Operating Temperature Range -10C to +50C
Storage Temperature Range -30C to +60C
E.O.L. Device TE-RH-E
Transmission Method Digital Communication using ESP
Maximum Humidity 95%RH - Non Condensing (at 40C)
Colour / Case Material Ivory White / ABS
Weight (g) / Diameter (mm) 75 / 100
Fixing Centres (mm) 48 ~ 74
Please Note: As of 1st January 2001, this product will be available only
on a Maintenance Replacement basis.
Hochiki Europe (UK) Ltd. reserves the right to alter the specification of its products from time to time without notice. Although every
effort has been made to ensure the accuracy of the information contained in this document it is not warranted or represented by
Hochiki Europe (UK) Ltd. to be a complete and up-to-date description.